This document includes a construction plan and related federal contract solicitation. The construction plan depicts existing site conditions and proposed demolition at the Stratford Army Engine Plant in Stratford, Connecticut. It provides details on drainage infrastructure, buildings, and other site features.

The related federal contract solicitation is from the U.S. Army Corps of Engineers, New England District seeking environmental remediation services at the Stratford Army Engine Plant. Specifically, the solicitation seeks mechanical dredging and disposal of approximately 13,000 cubic yards of sediment from an outfall drainage channel affected by metals and PCBs. The dredged material must be dewatered, solidified with cementitious materials, and a small portion requires off-site disposal at approved landfills. The period of performance is 375 calendar days. The NAICS code is 562910 and the solicitation is set aside for small businesses. Questions may be directed to the specified Contract Specialist and bids must be submitted through the System for Award Management website by the specified response date.

View the file

Other files

Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C O

N C

O R

D

M A

-2

V

IR

G

IN

IA

R

O A

D

N E

W E

N G

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

D R

A W

IN

G C

O D

E

S C

A L E

S H

E E

T O

F

S T

A E

P -0 of Engineers

US Army Corps

O U

T F

A L L

R

E M

E D

IA

T

IO

N

T

R A

T F

O R

D A

R M

Y E

N G

IN

E P

L A

N T

S T

R A

T F

O R

D

C O

N N

E C

T

IC

U T

ISSUE FOR CONSTRUCTION

W

W J

B

N/F

UNITED STATES OF AMERICA

550 MAIN STREET

BOOK 340 PAGE 122

EL=13.70'

STRATFORD SEWER MH

OF TOWN OF

HE WORD "TOWN"

CROSS OF "T" IN T

BENCHMARK

C h a in

L k

F e n c e

HOUSATONIC RIVER

Conc. Wall

C o n c

W a ll

Concrete Pad

C o n c

P a d

C o n c

P a d

Building

Pa dCo nc

Pa dCo nc

C o n c

W a ll

C o n c

W a ll

Co nc

W al l

F.

F.

.4

Trench Drain

Bi t.

Pa rk in g

P a d

C o n c

Pad

Conc.

Co nc

Wal l

C o n c

W a ll

Conc. Wall

Co nc

Wall

EMH

TF=10.2'

EMH

TF=9.9'

EMH

TF=9.4'

MH

TF=10.3'

INV IN(X)=EL' SIZE

INV OUT(X)=EL' SIZE

SUMP=X.X

DMH

TF=8.3'

INV(NE)=6.3' (12"RCP)

SUMP=5.8'

Bu ild ing

'C-L' CB

TF=9.5'

INV OUT(SW)=7.3' (4"PVC)

SILT SUMP=7.2'

SUMP=5.1'

INV IN(NW)=4.8' (6"PVC)

TF=9.5'

'C-L' CBIN

V

IN

N

E

.8 T

IL

E

IN

V

U

T S

W

.3 T

IL

E

C o n c

W a ll

Building

DMH

TF=10.1'

PIPE NOT VISIBLE

SUMP=5.5'

SUMP=4.0'

FL=5.1' (12"RCP)

TF=10.4'

DMH

SUMP=3.8'

NO PIPES VISIBLE

TF=10.3'

DMH

INV OUT(NW)=7.2' (12"C.I.)

INV IN(SE)=7.2' (6"C.I.)

TF=10.4'

MH

INACCESSIBLE

TF=10.2'

MH

'C-L' CB

TF=10.0'

INV IN(NE)=9.6' (4"D.I.)

INV OUT(SE)=9.4' (6"D.I.)

INV OUT(SW)=9.2' (2"PVC)

INV OUT(SW)=8.9' (4"PVC)

SUMP=8.1'

INV OUT(NE)=9.0' (6"D.I.)

INV IN(SW)=9.1' (6"PVC)

TF=9.8'

'C-L' CB

'C' CB

TF=9.0'

NO PIPE VISIBLE

SUMP=5.3'

C h a k

F e n c e

EMH

TF=10.2'

SMH

TF=9.8'

SMH

TF=9.8'

INV OUT(E)=6.1' (12"RCP)

INV IN(W)=6.3' (12"D.I.)

TF=10.3'

SMH

DMH

TF=10.2'

INV IN(SE)=6.6' (8"D.I.)

INV OUT(W)=6.4' (8"D.I.)

FL=4.7' (12"TILE)

as o f

De m ol is he d Bu ild in g

F.F.=10.1'

F.

F.

.9

Building

F.F.=10.8'

F .F

.7

C o n c

P a d

Bi t.

Wal k

B u il d in g

Conc. Pad

C o n c

P a d

C o n c

P a d

Conc. Pad

DMH

TF=10.3'

INV IN(W)=7.3' (6"PVC)

INV OUT(NW)=6.7' (6"D.I.)

INV OUT(SE)=6.8' (6"D.I.)

F e n c e

C h a in

L in k

Conc. Pad

FL(SW)=4.4' (24"RCP)

FL(NE)=4.4' (36"RCP)

FL(SE)=4.4' (12"RCP)

TF=10.4'

DMH

SUMP=7.8'

INV OUT(SE)=8.5' (8"PVC)

INV OUT(W)=7.9' (8"D.I.)

INV IN(SW)=8.9' (4"PVC)

TF=9.6'

'C-L' CB

'C' CB

TF=8.6'

NO PIPES VISIBLE

SUMP=3.6'

SUMP=-0.5'

TF=9.8'

MH

SUMP=0.5'

TF=9.9'

MH

SUMP=7.3'

INV OUT(NW)=7.9' (4"PVC)

TF=9.7'

'C-L' CB

FL=2.8' (15"RCP)

T.F.=10.2'

SMH

'C-L' CB

TF=9.6'

INV IN(E)=7.2' (8"D.I.)

INV OUT(S)=7.1" (6"D.I.)

INV OUT(SW)=5.3' (8"D.I.)

SUMP=5.4'

'C-L' CB

TF=9.4'

INV IN(S)=6.9' (6"D.I.)

INV OUT(W)=6.5' (8"D.I.)

SUMP=4.0'

YD

TF=8.8'

INV IN(NW)=7.2' (4"PVC)

INV OUT(SE)=4.7' (8"PVC)

SILT SUMP=2.8'

YD

TF=7.9'

INV IN(NW)=5.9' (12"RCP)

INV OUT(SW)=4.0'(12"RCP)

SILT SUMP=2.8'

IN

V

T S

W

.7 R

C P q

M e ta l

P la te s

YD

T.F.=8.0'

INV(NE)=5.9' (12"RCP)

SUMP=4.4'

YD

TF=9.1'

INV IN(NE)=5.4' (8"PVC)

FL=2.6' (24"D.I.)

SUMP=3.6'

SUMP=

4.

8'

IN

V

OUT(

NW)

5.

7'

8"

PVC)

TF

9.

1'YD

YD

TF=9.6'

INV IN(SW)=6.3' (12"RCP)

FL=6.2' (15"PVC)

YD

TF=9.2'

INV OUT(NE)=5.7' (12"RCP)

SUMP=4.4'

DMH

TF=9.9'

INV IN(SE)=4.6' (24"D.I.)

INV OUT(NE)=3.1' (24"D.I.)

SUMP=3.0'

G a te

C o n c

P a d

Pa dCo nc

Pa dBi t.

Pa dCo nc

Gr as s

Gr as s St on e

Pi le

El ec tri c

Eq ui pm en t

Gat e

Ta bl ePi cn ic

P ip e

C o n d u it

Pi pe C on du it

Pi pe C on du it

Electric Box

Pa dCo nc

8" Metal Pipe 12" Metal Pipe

M et al P ip e

M et al P ip e

Bit. Pad

Conc. Pad

Conc. Pad

Traffic Light

Pole

Traffic Control Box

Met al P ip e

Met al P ip e

Conc. Wall

Conc. Pad

C o n c

P a d

B it

W a lk

SUMP=

5.

3'

IN

V

OUT(

NW)

7.

3'

8"

PVC)

TF

9.

8''C

L' C

B

YD

TF=8.8'

INV=INACCESSIBLE

YD

TF=8.5'

INV IN(E)=6.1' (8"D.I.)

INV OUT(W)=5.8' (12"RCP)

SUMP=4.0'

'C-L' CB

TF=7.9'

INV IN(NE)=6.2' (8"CONC.)

SUMP=4.5'

DMH

TF=9.4'

INV IN(NW)=5.0' (8"D.I.)

INV OUT(S)=INACCESSIBLE

SUMP=1.7'

Building

Bu ild in g

Bu ild in g

Building

Building

YD

T.F

9.

5'

IN

V

OUT(

SE)

=6.

5' (8 "D .I.)

SUMP=5.

3'

FL=4.5'(13"RCP))

INV IN(NW)=8.0'(2"PVC)

T.F.=10.1'

DMH

'C-L' CB

TF=8.8'

INV IN(NE)=6.6' (8"CMP)

INV OUT(NW)=6.4' (8"CMP)

SUMP=4.0'

INV OUT(SE)=3.4' (15"RCP)

INV OUT(NW)=3.3' (15"RCP)

INV IN(SW)=8.0' (4"PVC)

TF=10.2'

SMH

'C-L' CB

TF=8.1'

PIPE NOT VISIBLE

SUMP=6.9'

SUMP=6.0'

INV OUT(SE)=6.3' (8"CMP)

INV IN(NW)=6.8' (10"CMP)

TF=8.4'

YD

SUMP=5.6'

INV IN(NW)=6.7'

TF=8.7'

YD

INV OUT(SW)=5.5'

INV IN(W)=5.6'

TF=9.4'

DMH

INV OUT(SE)=6.3' (8"CMP)

INV IN(N)=6.4' (8"CMP)

TF=9.6'

DMH

SUMP=6.5'

INV IN(NW)=8.2' (4"TILE)

TF=9.4'

YD

EMH

TF=10.2'

'C-L' CB

TF=10.2'

INACCESSIBLE

DMH

TF=10.2'

NO PIPE VISIBLE

SUMP=2.6'

INACCESSIBLE

TF=10.1'

MH

INV OUT (N)=4.5' (24"RCP)

INV OUT(NE)=4.4' (24"RCP)

INV IN(SW)=5.0' (12"RCP)

TF=10.0'

YD

YD

TF=10.1'

INV IN(SW)=7.3' (6"D.I.)

INV OUT(NE)=6.9' (8"D.I.)

SUMP=5.8'

YD

TF=10.2'

INV OUT(NW)=6.6' (8"D.I.)

SUMP=5.6'

DMH

TF=10.2'

INV OUT(E)=4.1' (36"RCP)

SUMP=4.1'

DMH

TF=10.0'

FL=4.0' (36"RCP)

SUMP=3.4'

DMH

TF=10.0'

INV IN(SW)=5.0' (12"RCP)

SUMP=2.6'

DMH

TF=9.4'

FL=4.1(12"RCP)

YD

TF=9.1'

INACCESSIBLE

DMH

TF=9.1'

INV IN(SW)=3.8' (12"RCP)

INV OUT(NE)=3.7' (12"RCP)

FL=4.2'(12"RCP)

FL=4.1(12"RCP)

TF=9.4'

DMH

INV OUT(SW)=3.7' (12"D.I.)

INV OUT(NW)=3.7' (16"D.I.)

INV OUT(NE)=3.4' (8"D.I.)

INV OUT(NE)=3.8' (6"D.I.)

INV IN(E)=3.8' (12"D.I.)

TF=10.2'

SMH

RCP

TF=10.1'

FL=6.0'

MH

TF=9.3'

INACCESSIBLE

EMH

TF=10.7'

INACCESSIBLE

TF=10.6'

YD

SUMP=7.5'

INV OUT(NW)=7.4' (6"D.I.)

INV IN(SW)=7.3' (6"D.I.)

TF=10.0'

YD

'C-L' CB

TF=9.7'

INV IN(SE)=7.8' (4"PVC)

INV OUT(SE)=4.4' (12"TILE)

INV OUT(NW)=4.3' (12"TILE)

INV OUT(NE)=7.7'' (4"D.I.)

EMH

TF=9.5'

EMH

TF=8.9'

MH

TF=10.0'

NO PIPE VISIBLE

SUMP=7.5'

MH

TF=10.1'

INACCESSIBLE

WMH

TF=10.3'

WMH

TF=10.4'

EMH

TF=9.1'

EMH

TF=9.0'

YD

TF=9.4'

NO PIPES VISIBLE

SUMP=2.7'

MH(BOLTED)

TF=10.0'

YD

TF=9.8'

INV OUT(SE)=7.7' (6"PVC)

SUMP=7.5'

MH(BOLTED)

TF=10.2'

MH(BOLTED)

TF=10.2'

SMH

TF=10.2'

INV IN(NE)=6.2' (8"PVC)

INV OUT(SE)=6.1' (12"D.I.)

INV OUT(NW)=6.2' (12"D.I.)

SMH

TF=10.0'

INV IN(NE)=7.0' (6"PVC)

INV OUT(SE)=5.9' (10"PVC)

INV OUT(NW)=6.0' (10"D.I.)

SMH

TF=10.0'

INV IN(NE)=7.0' (6"D.I.)

INV OUT(SW)=6.9' (6"PVC)

Conc. Pad

Bit.

MH

TF=10.0'

INACCESSIBLE

Bit. Walk

Bi t.

Wal k

Bi t.

Wal k

FF

.7

B u ild in g

FF=10.2'

Light Pole

Conc. Base

Conc. Base

Light Pole

S to n e

UNITED STATES OF AMERICA

550 MAIN STREET

BOOK 340 PAGE 122

Pad

Conc.

BLDG DEBRIS

AREA OF

"CL" CB

TF=10.12'

INACCESSIBLE

DMH

TF=8.9'

FL=7.1(6"PVC)

STORAGE TANK

ACCESS LID

TF=9.5'

INACCESSIBLE

TF=9.1'

MH

MH

TF=9.1'

INACCESSIBLE

Stone

St on e

St on e

F.

F.

.9

Conc.

Gra ss

Bit.

Building

FF=11.4'

'C

L' C

B

TF

9.

6'

IN

V

IN

(N

W) 7.

5'

6" D.

I.)

IN

V

OUT(

SE)

7.

4'

2"

PVC)

IN

V

OUT(

NE)

6.

8'

8"

CMP)

SUMP=

5.

5'

St on e

F.

F.

9.

Shed

Bit. Drive

Pad

Conc.

B u ild in g

S N

IF

F E

A

N E

3 4

D

.4

.5

.6

.7

.7

.8

D

D

.2

.3

D

D

.4

D

.4

.5

.5

.5

.6

D

.6

.6

S

D

.7

S

S

.8

S

.8

.9

.9

.9

D

S

.0

D

S

D

.1

S

D

D

.1

.1

S

S S

D

S S

D

.2

A C

D

.2

S

D

.3

D

S

.3

D

D

.4

.5

.6

.6

.7

.8

.9

.3

.6

.3

.4

.7

.4

.5

.5

.6

D

TID

AL M

UD F

LATS

S N

IF

F E

N S L

A N

E

B-1

B-6

B-5

B-3

B-3

B-6 4-1

B-4 4-1

B-4

B-4

B-1

B-1

B-4

B-4

B-4

B-9

EASEMENT

SANITARY SEWER

STRATFORD 15'

TOWN OF

G A

T E

G A

T E

G A

T E

...\Outfall 008 Remediation\30000 - Planning & Engineering & Design\30DA0 - Plans & Specs\CAD_BIM\_Sheets\DEMOLITION PLAN

12:11:22 PM 8/18/2021 PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript

A1

100'0 50'

A N

S I

D

CD102

:1

MATCHLINE SHEET CD103

M A

T C

H L

IN

E S

H E

E T C

D

M A

T C

H L

IN

E S

H E

E T C

D

TREATMENT SYSTEM

TO WATER

OF-008 WORK AREA

SOUTH LOT AND

CONDUIT FROM

SNIFFENS LANE FOR

TRENCH ACROSS

EXISTING CONDITIONS AND DEMOLITION PLAN

SCALE: 1" = 50'

WATER

MEAN HIGH

E X

IS

T

IN

G C

O N

D

IT

IO

N S A

N D D

E M

O L

IT

IO

N P

L A

N

B .S

P R

A G

U E

B .S

P R

A G

E

T

H

IB

O D

E A

U

/1

/2

L T

H

IB

O D

E A

U

PRIOR TO CONTRACT WORK

CLEARED TO GRADE BY OTHERS

AREA DEMOLISHED AND

A

U G

R E

V

IS

E D T

O R

E M

O V

E D

E M

O L

IT

IO

N F

R O

M S

C O

P E O

F C

O N

T R

A C

T W

O R

K

File details come from the government source that posted it. Updated .