Q and A Addendum 07 27Oct2020 102554_ - Sheet - AD010 - GROUND FLOOR DEMOLITION PLAN.pdf

PDF 2 MB Posted

Attached to
B222 Renovation and Addition
Solicitation number
W912LM20R1003
Issued by

About this file

This solicitation seeks proposals for a firm fixed-price construction contract to renovate and add to an existing base supply facility for the Minnesota Air National Guard. Work includes repairing metal flashing and exterior doors, rehabilitating face brick, addressing drainage issues, selectively demolishing walls to reconfigure interior spaces, and replacing electrical, HVAC, plumbing and fire protection systems. The addition must utilize conventional construction methods and match existing materials and designs. The project budget is between $5-10 million and work must be completed within 540 days of the notice to proceed. Proposals are due by October 29, 2020. Evaluation criteria are best value past performance and price. The contract will be awarded without discussions to the responsible offeror providing the best value to the government.

View the file

Other files

File Type Posted
Addendum 09.doc DOC document
B 08 W912LM20R1003 Amendment 01 B222 Renovation and Addition.pdf PDF
Addendum 08.doc DOC document
Q and A Addendum 07 27Oct2020 102554_ - Sheet - A-353 - SECTION DETAILS.pdf PDF
Q and A Addendum 07 27Oct2020 08 71 00.pdf PDF
Addendum 07.doc DOC document
Q and A Addendum 07 27Oct2020 08 11 13.pdf PDF
Q and A Addendum 07 27Oct2020 08 81 00.pdf PDF
Q and A Addendum 07 27Oct2020 08 51 13.pdf PDF
Q and A Addendum 07_Structural.pdf PDF
B222_2007_ExistingWindowInformation.pdf PDF
222-1984-84005-Addition to Engine Shop.pdf PDF
222-1976-Original Construction.pdf PDF
B222_2007_Renovation.pdf PDF
Addendum 05 and 06.doc DOC document
Q and A Addendum 05 09 29 00 26OCT20.pdf PDF
Q and A Addendum 05 08 33 13 26OCT20.pdf PDF
Q and A Addendum 03 Architecture.pdf PDF
Addendum 03 and 04.doc DOC document
Q and A Addendum 01_02 (08 71 00).pdf PDF
Q and A Addendum 01_02 (07 05 23).pdf PDF
Q and A Addendum 01_02 (102554_Elec_PanelboardSchedules_Add01).pdf PDF
Addendum 01 and 02.doc DOC document
Q and A Addendum 01_02 (07 27 10.00 10).pdf PDF
Q and A Addendum 01_02 (08 81 00).pdf PDF
Q and A Addendum 01_02 (14 21 23).pdf PDF
Preproposal Conference.pdf PDF
MATOC Preproposal Conference.pdf PDF
B222 Site visit.pdf PDF
B 04 DB Wage Det 28 Sep.pdf PDF
EXHIBIT A Ld.doc DOC document
EXHIBIT B Ld.doc DOC document
148FW Form 66.pdf PDF
EXHIBIT_C_-_Reference_Questionnaire_Package NEW Ld.docx DOCX document
B 08 W912LM20R1003 B222 Renovation and Addition.pdf PDF
Exhibit D_Letter of Commitment Ld.docx DOCX document
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

UP

D4

D4

D4

D4

D4

D4

D4

D4

D4

D4

D4

D4

D4 D4

D4

D4 D4

D4

D4

D4

D4

D4

D4 D4

D4

D4

D4

D4

D4

D4

D4

D4 D4

D1

D1

D1

D1 D1

D1

D1

D1

D17 6'

8'

(F.V.)

14' - 2 1/2" 3' - 4"

D1

D1 D1

D1

D1

D1

D1

D1 D1

D1

D1

D1

D1

D1

D1

D5D5

D5

D4

D5 D5

D7

D1D1

D1

D1

D1

D1

D7

D5

D2 D10

D2

D8 D2 D13

D8

D2 D12

D1

D1

D1

D4

D4

D2

D14 D2

D2

D2

D14

D1

D1

(TYP.)

(TYP.)

(TYP.)

(TYP.)

D4

D15 (TYP.)

D1

7' - 0" 13' - 3 1/4"

(FIELD VERIFY)

26' - 1 1/4" 12' - 0"

D1

D1

D17

6'

5'

D16 D16

D15

(TYP.)

D16 D16

D1

D1

D12

D1

D1

D11

(TYP.)

D6

D6

D6

D6

D6

D6

D6

D6

D6 D6

D6

D6 D6

D6

D6

D6

D6

D6

D6

D6

D6

D6

D6

D6

D6

D6

D6 D6

D6

D6

D6

D6 D6

D6 D6

D6

D6

D18

D1

D4

D1

COORDINATE WALL

DEMOLITION

LOCATION W/ NEW

CORRIDOR 102 ON

SHEET A-404 1' - 8" 3' - 4" 18' - 7 7/8" 6' - 0"

D1 D17

D17

D17

3/ 4"

8'

/4

1/ 8"

8'

/4

6'

6'

" D29

D29

D29

D29D29

D29

D29 D29

D29

D29

D29

D29

D29

D1

TYP.

OF 3

20' - 0"

D1

D4 D26 D26 D26 D26 D26D1

D26 D26 D26 D26 D26

D7

EXISTING CONDITIONS SHOWN ON DRAWINGS ARE FOR INFORMATIONAL PURPOSES ONLY

AND DO NOT SHOW ALL CONDITIONS THAT MAY AFFECT THE WORK OF THIS CONTRACT.

CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS. REFER TO ALL

ARCHITECTURAL, PLUMBING,

MECHANICAL, ELECTRICAL, AND STRUCTURAL DRAWINGS FOR ADDITIONAL DEMOLITION

INFORMATION AND COORDINATION.

FIELD VERIFY EXISTING CONDITIONS BEFORE COMMENCING ANY WORK. ARCHITECT SHALL

BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES DETRIMENTAL TO THE PROPER

EXECUTION OF NEW CONSTRUCTION.

ALL DEMOLITION WORK SHALL COMPLY WITH APPLICABLE BUILDING CODE AND ALL

APPLICABLE LOCAL, STATE, AND FEDERAL LAWS, ORDINANCES, AND REGULATIONS. SEE

CODE SUMMARY SHEET FOR APPLICABLE BUILDING CODE.

REMOVE EXISTING CONSTRUCTION TO THE EXTENT INDICATED ON THE DRAWINGS.

PROTECT ALL OTHER EXISTING STRUCTURES ON ADJACENT PROPERTIES FROM DAMAGE

THROUGHOUT CONSTRUCTION. SHOULD ANY DAMAGE OCCUR TO ANY EXISTING

CONSTRUCTION ON ADJACENT PROPERTIES OR EXISTING CONSTRUCTION TO REMAIN ON

SITE, THE CONTRACTOR SHALL

REPAIR THE DAMAGE TO THE SATISFACTION OF THE PROPERTY OWNER.

CONTRACTOR SHALL PROTECT ALL EXISTING CONSTRUCTION NOTED TO REMAIN FROM

DAMAGE AND SOILING DURING DEMOLITION. REMOVE DEBRIS REGULARLY AS NECESSARY

TO ELIMINATE INTERFERENCE.

EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED,

OR OTHERWISE INDICATED TO REMAIN THE OWNER’S PROPERTY, DEMOLISHED MATERIALS

SHALL BECOME THE CONTRACTOR’S PROPERTY AND SHALL BE REMOVED FROM THE SITE

WITH FURTHER DISPOSITION AT THE CONTRACTOR’S OPTION.

EXISTING WALLS SHOWN GRAPHICALLY WITH SOLID LINES TO REMAIN. PROTECT ALL

EXISTING CONSTRUCTION TO REMAIN AND PREPARE SURFACES TO RECEIVE NEW

CONSTRUCTION OR FINISHES.

ALL DEMOLISHED MATERIALS SHALL BE LEGALLY DISPOSED OF PROMPTLY. DO NOT ALLOW

DEMOLISHED MATERIALS TO ACCUMULATE ON SITE. NO BURNING IS ALLOWED.

GENERAL FLOOR PLAN DEMOLITION NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

PROTECT ALL ADJACENT AREAS FROM THE DEMOLITION. REPAIR OR REPLACE, AT NO

COST TO THE OWNER, ALL AREAS OR ITEMS DAMAGED DURING THE DEMOLITION.

LIMITS OF CONTRACT TO EXTEND UP TO, AND INCLUDE, THE PROPERTY LINES, AND SHALL

NOT EXTEND BEYOND THESE LIMITS ONTO PUBLIC OR PRIVATE PROPERTY, EXCEPT AS

INDICATED ON THE DRAWINGS.

WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL ELEMENTS THAT

CONFLICT WITH THE INTENDED FUNCTION OR DESIGN ARE ENCOUNTERED, DETERMINE

THE NATURE AND EXTENT OF THE CONFLICT AND NOTIFY THE ARCHITECT IMMEDIATELY

FOR RESOLUTION.

IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN THE WORK.

IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS ARE ENCOUNTERED,

DO NOT DISTURB; IMMEDIATELY NOTIFY SUPERINTENDENT AND OWNER. OWNER WILL

REMOVE HAZARDOUS MATERIALS UNDER A SEPARATE CONTRACT.

THIS DEMOLITION PLAN OUTLINES THE SCOPE OF THE WORK INVOLVED FOR THE

DEMOLITION PHASE OF THIS PROJECT. CONTRACTOR SHALL ALSO REFER TO THE

DRAWINGS FOR THE CONSTRUCTION OF THE NEW ADDITION FOR ADDITIONAL

INFORMATION.

ALL WORK MUST BE COORDINATED WITH THE OWNER WITH REGARD TO SCHEDULE AND

DISRUPTION OF BUSINESS OPERATIONS.

ALL FURNITURE WILL BE REMOVED OR RELOCATED BY THE OWNER AS NECESSARY PRIOR

TO THE DEMOLITION WORK OF THIS PROJECT.

ALL DEMOLITION WORK SHALL BE COORDINATED WITH THE OTHER WORK OF THIS

PROJECT AS OUTLINED IN THE DOCUMENTS. ANY DISCREPANCIES NOTED WHICH WILL

IMPACT THE SCHEDULE FOR CONSTRUCTION OR HAVE AN EFFECT ON THE CONTINUED

OPERATION OF BUSINESS AT THIS FACILITY SHALL BE BROUGHT TO THE IMMEDIATE

ATTENTION OF THE ARCHITECT FOR RESOLUTION.

DO NOT INTERRUPT EXISTING UTILITIES, EXCEPT WHEN AUTHORIZED IN WRITING BY

AUTHORITIES HAVING JURISDICTION. PROVIDE TEMPORARY SERVICES DURING

INTERRUPTIONS TO EXISTING UTILITIES, AS ACCEPTABLE TO GOVERNING AUTHORITIES.

WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED, RELOCATED, OR ABANDONED,

PROVIDE BYPASS CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE BEFORE

PROCEEDING WITH DEMOLITION.

PRIOR TO COMMENCEMENT WITH ANY DEMOLITION WORK, CONTRACTOR SHALL IDENTIFY

ALL ELECTRICAL CIRCUITS SERVICING THE AREA INVOLVED WITH THIS DEMOLITION. THOSE

CIRCUITS SHALL THEN BE LOCKED OUT AND TAGGED OUT IF THEY DO NOT SERVICE ANY OF

THE REMAINING BUILDING. THOSE CIRCUITS WHICH ARE IDENTIFIED TO SERVICE BOTH THE

AREA TO BE DEMOLISHED AND THE

REMAINING BUILDING SHALL BE SPLIT SO AS TO KILL ALL ELECTRICAL POWER TO THE AREA

TO BE DEMOLISHED WHILE MAINTAINING POWER TO THE REMAINDER OF THE BUILDING.

CARE SHOULD BE MADE TO KEEP DUST AND NOISE FROM DEMOLITION ACTIVITIES FROM

THE OTHER PORTIONS AND FLOORS OF THE BUILDING. ERECT AND MAINTAIN DUSTPROOF

PARTITIONS. COVER AND PROTECT FURNITURE, FURNISHINGS AND EQUIPMENT THAT HAVE

NOT BEEN REMOVED.

PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION REQUIRED TO PREVENT

INJURY TO PEOPLE AND DAMAGE TO ADJACENT BUILDING AREAS TO REMAIN.

NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE AND TRUE TO DIMENSIONS REQUIRED.

USE CUTTING METHODS LEAST LIKELY TO DAMAGE ADJOINING CONSTRUCTION TO REMAIN.

REMOVE ALL EXISTING CARPET AND EXISTING RUBBER BASE FROM ALL AREAS TO BE

REMODELED. FLOOR MUST BE FREE OF DUST, DIRT, OIL, GREASE, PAINT, WAX OR ANY

DEBRIS THAT COULD AFFECT ADHESION OF THE CARPET MODULES TO THE FLOOR DURING

BUILD-BACK PHASE.

DRYWALL PARTITIONS: REMOVE GYPSUM BOARD, STEEL FRAMING, RUNNERS, TRACKS,

ANCHORS AND FASTENERS, UNLESS OTHERWISE NOTED OR SHOWN. PATCH ANCHOR

HOLES WHERE CEILING, WALLS, AND FLOORS ARE TO REMAIN.

PRIOR TO DEMOLITION, MAKE SURE PLUMBING IS CUT AND CAPPED AT ALL SINK

LOCATIONS, REMOVE CABINETRY, CASEWORK, SINKS, AND COUNTERTOPS. REFERENCE

MECHANICAL DRAWINGS FOR PLUMBING AND PIPES.

CONTRACTOR SHALL COMPLY WITH ALL NECESSARY FIRE SAFETY REQUIREMENTS IN

ACCORDANCE WITH NFPA 13, UFC 3-600-01 AND CURRENTLY ADOPTED CITY AND STATE

CODES.

WHERE EXISTING FLOOR FINISHES ARE REMOVED, THOROUGHLY CLEAN, SCRAPE, GRIND

AND/OR PATCH AS REQUIRED TO PREPARE FOR NEW FLOORING.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

EXISTING DOOR

DOOR TO BE REMOVED

EXISTING WALL

WALL TO BE REMOVED

DEMOLITION / EXISTING PLAN

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.

ROBERT J. KENNALEY

DATE: 10/27/20 LIC. NO. 54022

date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

no. date descriptionby ckd

1 1312111098765432

I

H

G

F

E

D

C

B

A

B222 RENOVATION AND ADAL

xxx

US NATIONAL GUARD BUREAU

MN ANG, 148TH FIGHTER WING

DULUTH, MINNESOTA

8201 NORMAN CENTER DR.

BLOOMINGTON, MN 55437

763-277-4676

102554

KEYPLAN

AREA A

AREA B

D

102554_A_CENTRAL.RVT

AD010

GROUND FLOOR DEMOLITION PLAN

08/01/19

J. TOP B. KENNALEY

C.SPRINK

SCALE: 3/32" = 1'-0"E1

GROUND FLOOR DEMOLITION PLAN

0 8' 16' 24'

N

KEYED NOTE LEGEND

D1 REMOVE EXISTING WALL

D2 REMOVE EXISTING PLUMBING FIXTURE

D4 REMOVE EXISTING DOOR, FRAME AND HARDWARE

D5 REMOVE EXISTING OVERHEAD DOOR, FRAME, TRACKS AND HARDWARE

D6 REMOVE EXISTING FLOOR FINISH DOWN TO CONCRETE SLAB

D7 REMOVE EXISTING STAIRS, GUARDRAILS AND/OR HANDRAILS

D8 REMOVE EXISTING LOCKERS

D10 REMOVE EXISTING SHOWER, ROD, CURTAIN AND PIPING

D11 REMOVE EXISTING MOP SINK

D12 REMOVE EXISTING TOILET PARTITION

D13 REMOVE EXISTING URINAL SCREEN

D14 REMOVE EXISTING TOILET ACCESSORY

D15 REMOVE EXISTING COLUMN (FOR BRIDGE CRANE SYSTEM)

D16 REMOVE EXISTING GUARD POSTS (TYP. AT THIS DOOR)

D17 REMOVE PARTIAL WALL REQUIRED FOR INSTALLATION OF WINDOW

D18 REMOVE EXISTING DOCK BUMPER

D26 REMOVE EXISTING WINDOW

D29 REMOVE DOOR AND FRAME, PREPARE FOR NEW DOOR

N

NOTE: THE EXISTING OVERHEAD BRIDGE CRANE COLUMNS AND

ASSOCIATED FRAMING IN THE WAREHOUSE IS TO BE REMOVED

ENTIRELY. CONTRACTOR TO FIELD VERIFY THE EXISTING BRIDGE

CRANE SUPPORT STRUCTURE IS INDEPENDENT FROM THE BUILDING

STRUCTURAL WALL AND ROOF FRAMING PRIOR TO REMOVAL.

D

A 05/23/19 JT KY TYPE B-1 SUBMITTAL

B 08/01/19 JT KY TYPE B-2 SUBMITTAL

C 01/03/20 JT BK TYPE B-3 SUBMITTAL

D 10/27/20 JT BK ADDENDUM 7