Q and A Addendum 03 Architecture.pdf

PDF 277 KB Posted

Attached to
B222 Renovation and Addition Federal contract opportunity
Solicitation number
W912LM20R1003
Issued by
Department of the Army Minnesota Army National Guard

About this file

This document contains a federal contract solicitation for construction services and an addendum to architectural drawings. The solicitation seeks a firm fixed-price contract to renovate and add to an existing base supply facility for the Minnesota Air National Guard. Work includes repairing metal flashing and roofs, replacing doors, reconfiguring interior partitions, and upgrading electrical, HVAC, plumbing and fire protection systems. The project must comply with DoD antiterrorism requirements and use local materials and techniques where cost-effective. The solicitation includes options for communication cable, a dock leveler, epoxy flooring, an intrusion system and access control. The magnitude is $5-10 million and construction time is 540 days. The NAICS code is 236220 and it is a small business set-aside. The pre-proposal conference is October 7th and questions are due by October 26th. Proposals are due October 29th and will be evaluated based on past performance and price. The addendum provides architectural drawings and notes for an office area, TMO room and door schedule.

View the file

Other files for this federal contract opportunity

Other files attached to B222 Renovation and Addition, newest first.
File Type Posted
Addendum 09.doc DOC document
B 08 W912LM20R1003 Amendment 01 B222 Renovation and Addition.pdf PDF
Addendum 08.doc DOC document
Q and A Addendum 07 27Oct2020 08 81 00.pdf PDF
Q and A Addendum 07_Structural.pdf PDF
Q and A Addendum 07 27Oct2020 102554_ - Sheet - A-353 - SECTION DETAILS.pdf PDF
Q and A Addendum 07 27Oct2020 102554_ - Sheet - AD010 - GROUND FLOOR DEMOLITION PLAN.pdf PDF
Q and A Addendum 07 27Oct2020 08 11 13.pdf PDF
Q and A Addendum 07 27Oct2020 08 71 00.pdf PDF
Q and A Addendum 07 27Oct2020 08 51 13.pdf PDF
Addendum 07.doc DOC document
222-1976-Original Construction.pdf PDF
B222_2007_Renovation.pdf PDF
222-1984-84005-Addition to Engine Shop.pdf PDF
B222_2007_ExistingWindowInformation.pdf PDF
Q and A Addendum 05 09 29 00 26OCT20.pdf PDF
Q and A Addendum 05 08 33 13 26OCT20.pdf PDF
Addendum 05 and 06.doc DOC document
Addendum 03 and 04.doc DOC document
Addendum 01 and 02.doc DOC document
Q and A Addendum 01_02 (07 05 23).pdf PDF
Q and A Addendum 01_02 (08 81 00).pdf PDF
Q and A Addendum 01_02 (14 21 23).pdf PDF
Q and A Addendum 01_02 (08 71 00).pdf PDF
Q and A Addendum 01_02 (102554_Elec_PanelboardSchedules_Add01).pdf PDF
Q and A Addendum 01_02 (07 27 10.00 10).pdf PDF
Preproposal Conference.pdf PDF
MATOC Preproposal Conference.pdf PDF
B222 Site visit.pdf PDF
B 04 DB Wage Det 28 Sep.pdf PDF
148FW Form 66.pdf PDF
EXHIBIT B Ld.doc DOC document
B 08 W912LM20R1003 B222 Renovation and Addition.pdf PDF
Exhibit D_Letter of Commitment Ld.docx DOCX document
EXHIBIT_C_-_Reference_Questionnaire_Package NEW Ld.docx DOCX document
EXHIBIT A Ld.doc DOC document
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ORDERLY

SEMI-

PRIVATE

LGLO SMSgt

CMSgt

FIRST

SERGEANT

CMSgt

CORRIDOR

LOGISTICS

READINESS

OFFICER

LRO

COMMANDER

DEPUTY

CMDR

ORDERLY

WORK

ROOM

WAREHOUSE

S2AB

S2AB

S2AB

S2AB

S2AB

S2AB

S2AB

S2AB

S2AB

F1CA

F1CA F1CA

F1CA

F1CA

F1CA

F1CA

10' - 8"

W01

105A

107A

108A

112B

110A

24' - 9"

2' - 2 1/4"

10' - 2" 5' - 0 1/4"

W01

W01

W01

W01

104A

103A

106A

111A

109A

10' - 10" 5' - 0 1/4" 10' - 0"

I1

A-451

E10

A-451

S2AB

S2AB

S2AB

F1CA

F1CA

S2AB

E5

Sim A-451

P1

P1

P1

P1

CUT OPENING IN

EXISTING WALL 5'-0"

WIDE BY 10'-0" TALL

CUT OPENING IN

EXISTING WALL 5'-0"

WIDE BY 10'-0" TALL

4' - 4 1/4"

CORRIDOR

CORRIDOR

VEST

S2CA

MIN 1'-0"

ALIGN

S2AB

S2AB

S2AB

S2AB

EXISTING DOOR

NEW DOOR

EXISTING WALL

NEW WALL (RE: PARTITION TYPE)

PLAN LEGEND:

B

C

TMO

DEPLOYMENT

PROCESSING

CENTER

WAREHOUSE

138A

138B

138C

W02 W02 W02 W02 W02 W02

W02W02

W02

EQ. 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" EQ.

S2BA

S2BA

S2BA

BOLLARD BOLLARD

FIELD VERIFY: ALIGN WALLS W/ TUBE STEEL COLUMNS

46' - 11 3/4"

1' - 0"

1' - 0"

SHIPPING /

RECEIVING

PACKING &

CRATING

COLUMN COLUMN

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.

ROBERT J. KENNALEY

DATE: 10/20/20 LIC. NO. 54022

date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

no. date descriptionby ckd

1 1312111098765432

I

H

G

F

E

D

C

B

A

B222 RENOVATION AND ADAL

xxx

US NATIONAL GUARD BUREAU

MN ANG, 148TH FIGHTER WING

DULUTH, MINNESOTA

8201 NORMAN CENTER DR.

BLOOMINGTON, MN 55437

763-277-4676

102554

D

102554_A_CENTRAL.RVT

A-404

ENLARGED PLANS - OFFICE AREA & TMO

08/01/19

J. TOP B. KENNALEY

C.SPRINK

SCALE: 1/4" = 1'-0"I1

ENLARGED OFFICE AREA PLAN

0 2' 4' 8'

N

KEYED NOTE LEGEND

P1 INFILL OPENING WITH WALL CONSTRUCTION SIMILAR TO ADJACENT

WALL

SCALE: 1/4" = 1'-0"H6

ENLARGED PLAN - TMO ROOM 138

0 2' 4' 8'

N

D

A 05/23/19 JT KY TYPE B-1 SUBMITTAL

B 08/01/19 JT KY TYPE B-2 SUBMITTAL

C 01/03/20 JT BK TYPE B-3 SUBMITTAL

D 10/20/20 JT BK ADDENDUM 3

NL FL

A

SCHEDULE

DOOR PER A

B

S C

H E

D U

L E

D O

O R

P E

R

D O

O R

P E

R S

C H

E D

U L E

SCHEDULE

DOOR PER

D O

O R

P E

R S

C H

E D

U L E

A

D

D O

O R

P E

R S

C H

E D

U L E

B C

B

SCHEDULE

DOOR PER

SCHEDULE

DOOR PER

D

A A

OH

D O

O R

P E

R S

C H

E D

U L E

DOOR PER SCHEDULE

F1

1.S C

H E

D U

L E

D O

O R

P E

R B A

E

A

ASCHEDULE

DOOR PER

F

GLASS OR PANEL INFILL TYPES:

REFERENCE SPECIFICATION FOR GLASS TYPES

1 INSULATED LOW E, (1")

2 INSULATED LOW E, TEMPERED (1")

3 CLEAR LAMINATED FIRE SAFETY - 20 MINUTE (1")

DOOR & DOOR FRAME GENERAL NOTES:

1.

2.

3.

4.

5.

6.

FIELD VERIFY EXISTING FRAMES AND CONFIRM COMPATIBILITY WITH NEW DOORS

AND HARDWARE PRIOR TO CONSTRUCTION.

# ON DOOR ELEVATION REPRESENTS GLASS PANEL ON DOOR.

ALL HM DOORS AND DOOR FRAMES ARE GALVANIZED.

ALL OH EXTERIOR DOORS ARE INSULATED.

ALL NL AND NL-IN TYPE DOORS USE TYPE-2 GLASS UNLESS NOTED OTHERWISE.

OVERHEAD COILING SHUTTER DOOR.

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.

ROBERT J. KENNALEY

DATE: 10/20/20 LIC. NO. 54022

date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

no. date descriptionby ckd

1 1312111098765432

I

H

G

F

E

D

C

B

A

B222 RENOVATION AND ADAL

xxx

US NATIONAL GUARD BUREAU

MN ANG, 148TH FIGHTER WING

DULUTH, MINNESOTA

8201 NORMAN CENTER DR.

BLOOMINGTON, MN 55437

763-277-4676

102554

D

102554_A_CENTRAL.RVT

A-601

DOOR SCHEDULE

08/01/19

J. TOP B. KENNALEY

C.SPRINK

DOOR SCHEDULE

DOOR

NUMBER

DOOR FRAME

ASSEMBLY

RATING STC

DETAIL

HARDWARE

SET REMARKS

SIZE

TYPE MATERIAL TYPE MATERIAL HEAD JAMB SILL

PAIR

DOOR WIDTH HEIGHT

GROUND FLOOR

101A - 3' - 0" 7' - 0" FL-IN HM 10.1 HM - - C4 / A-611 C11 / A-611 I4 / A-611 2.0 NEW DOOR IN EXISTING OPENING

101B - 3' - 0" 7' - 0" FL-IN HM 10.1 HM - - C1 / A-611 C11 / A-611 I1 / A-611 5.0 NEW DOOR IN EXISTING OPENING

103A - 3' - 0" 7' - 0" NL HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 14.0

104A - 3' - 0" 7' - 0" NL HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 14.0

105A - 3' - 0" 7' - 0" NL HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 14.0

106A - 3' - 0" 7' - 0" NL HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 14.0

107A - 3' - 0" 7' - 0" NL HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 14.0

108A - 3' - 0" 7' - 0" NL HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 14.0

109A - 3' - 0" 7' - 0" NL HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 14.0

110A - 3' - 0" 7' - 0" NL HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 14.0

111A - 3' - 0" 7' - 0" NL HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 14.0

112A - 3' - 0" 7' - 0" F HM 1.1 HM 20 MIN - C1 / A-611 F1 / A-611 I1 / A-611 24.0

112B - 3' - 0" 7' - 0" F-V HM 1.1 HM - - C4 / A-611 F4 / A-611 I4 / A-611 15.0

113A - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - C8 / A-611 F8 / A-611 I8 / A-611 23.0 FOR BID OPTION USE ALTERNATE DOOR HW SET # 35.0

113B 12' - 0" 10' - 0" OH-C STL STL - C1 / A-612 F1 / A-612 I1 / A-612 33.0

114A - 3' - 0" 7' - 0" F HM 1.2 HM 20 MIN - C4 / A-611 F4 / A-611 I4 / A-611 22.0

114B 6' - 0" 4' - 8" OH-S STL STL - C8 / A-612 F8 / A-612 I8 / A-612 33.0

114C 6' - 0" 4' - 0" OH-S STL STL - C11 / A-612 F11 / A-612 I11 / A-612 33.0

115.1A - 3' - 0" 7' - 0" F HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 16.0

115A - 3' - 0" 7' - 0" F HM 1.2 HM - - C4 / A-611 F4 / A-611 I4 / A-611 20.0

115B 6' - 0" 4' - 8" OH-S STL STL 20 MIN - C8 / A-612 F8 / A-612 I8 / A-612 33.0

115C - 3' - 0" 7' - 0" F HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 21.0

116A - 2' - 6" 7' - 0" F HM 1.2 HM - - C4 / A-611 F4 / A-611 I4 / A-611 32.0 NEW DOOR IN EXISTING OPENING

117A PR. 3' - 0" 7' - 0" F-V HM 1.2 HM - - C4 / A-611 F4 / A-611 I4 / A-611 6.0 NEW DOOR IN EXISTING OPENING

118A - 3' - 0" 7' - 0" F HM 1.2 HM - - C4 / A-611 F4 / A-611 I4 / A-611 10.0 NEW DOOR IN EXISTING OPENING

119A PR. 3' - 0" 7' - 0" F-V HM 1.2 HM - - C8 / A-611 F8 / A-611 F11 / A-611 4.0 NEW DOOR IN EXISTING OPENING

120A - 3' - 0" 7' - 0" FL HM 10.1 HM - - C4 / A-611 C11 / A-611 I4 / A-611 2.0 NEW DOOR IN EXISTING OPENING

120B - 3' - 0" 7' - 0" FL HM 10.1 HM - - C1 / A-611 C11 / A-611 I1 / A-611 5.0 NEW DOOR IN EXISTING OPENING

121A - 3' - 0" 7' - 0" F HM 1.2 HM - - C4 / A-611 F4 / A-611 I4 / A-611 9.0 FOR BID OPTION USE ALTERNATE DOOR HW SET # 34.0.

121B 12' - 0" 12' - 0" OH-C STL STL - C4 / A-612 F4 / A-612 I4 / A-612 33.0

121C 6' - 0" 4' - 8" OH-S STL STL 20 MIN - C8 / A-612 F8 / A-612 I8 / A-612 33.0

122A PR. 3' - 0" 7' - 0" F-V HM 1.2 HM 20 MIN - C4 / A-611 F4 / A-611 I4 / A-611 31.0 NEW DOOR IN EXISTING OPENING

122B PR. 3' - 0" 7' - 0" F HM 1.2 HM 20 MIN - C4 / A-611 F4 / A-611 I4 / A-611 29.0

122C - 3' - 0" 7' - 0" F HM 1.2 HM 20 MIN - C4 / A-611 F4 / A-611 I4 / A-611 30.0

123A - 3' - 0" 7' - 0" F HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 27.0

124A - 3' - 0" 7' - 0" F HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 26.0

126A - 3' - 0" 7' - 0" F HM 1.1 HM - - C1 / A-611 F1 / A-611 I1 / A-611 26.0

128A - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - C8 / A-611 F8 / A-611 I8 / A-611 11.0

129A PR. 3' - 0" 7' - 0" F HM 1.2 HM - 45 C4 / A-611 F4 / A-611 I4 / A-611 7.0 FOR BID OPTION USE ALTERNATE DOOR HW SET # 37.0.

130A - 3' - 0" 7' - 0" F-V HM 1.2 HM - - C8 / A-611 F8 / A-611 F11 / A-611 3.0 NEW DOOR IN EXISTING OPENING

130B 12' - 0" 12' - 0" OH-C STL STL - C4 / A-612 F4 / A-612 I4 / A-612 33.0 NEW DOOR IN EXISTING OPENING

130C - 3' - 0" 7' - 0" F-V HM 1.2 HM - - C8 / A-611 F8 / A-611 I8 / A-611 23.0 FOR BID OPTION USE ALTERNATE DOOR HW SET # 35.0

130D 12' - 0" 12' - 0" OH-C STL STL - C1 / A-612 F1 / A-612 I1 / A-612 33.0

131A - 3' - 0" 7' - 0" F HM 1.2 HM 20 MIN - C4 / A-611 F4 / A-611 I4 / A-611 17.0

132A - 3' - 0" 7' - 0" F HM 1.2 HM - - C8 / A-611 F8 / A-611 F11 / A-611 1.0 NEW DOOR IN EXISTING OPENING

133A - 3' - 0" 7' - 0" F HM 1.2 HM 20 MIN - C4 / A-611 F4 / A-611 I4 / A-611 12.0

133B PR. 4' - 0" 7' - 0" F HM 1.2 HM 20 MIN - C8 / A-611 F8 / A-611 I8 / A-611 28.0

134A - 3' - 0" 7' - 0" F HM 1.2 HM - - C8 / A-611 F8 / A-611 F11 / A-611 3.0 NEW DOOR IN EXISTING OPENING

134B PR. 3' - 0" 7' - 0" F HM 1.2 HM 20 MIN - C8 / A-611 F8 / A-611 I8 / A-611 29.0

135A - 3' - 0" 7' - 0" F HM 1.2 HM - - C4 / A-611 F4 / A-611 I4 / A-611 18.0

135B 10' - 0" OH-C STL STL - C4 / A-612 F4 / A-612 I4 / A-612 33.0

136A - 3' - 0" 7' - 0" F HM 1.2 HM - - C4 / A-611 F4 / A-611 I4 / A-611 18.0

137A 12' - 0" 10' - 0" OH-C STL STL - C1 / A-612 F1 / A-612 I1 / A-612 33.0

137B - 3' - 0" 7' - 0" F-V HM 1.2 HM - - C8 / A-611 F8 / A-611 F11 / A-611 3.0

137C 12' - 0" 10' - 0" OH-C STL STL - C1 / A-612 F1 / A-612 I1 / A-612 33.0

137D 9' - 0" 10' - 0" OH-C STL STL - C1 / A-612 F1 / A-612 I1 / A-612 33.0

137E 10' - 0" 10' - 0" OH-C STL STL - C1 / A-612 F1 / A-612 I1 / A-612 33.0

137F - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - C8 / A-611 F8 / A-611 F11 / A-611 3.0

138A - 3' - 0" 7' - 0" F HM 1.1 HM 20 MIN - C1 / A-611 F1 / A-611 I1 / A-611 25.0

138B - 3' - 0" 7' - 0" F HM 1.1 HM 20 MIN - C1 / A-611 F1 / A-611 I1 / A-611 25.0

138C - 3' - 0" 7' - 0" F HM 1.1 HM 20 MIN - C1 / A-611 F1 / A-611 I1 / A-611 25.0

139A PR. 3' - 0" 7' - 0" F HM 1.2 HM 20 MIN - C1 / A-611 F1 / A-611 I1 / A-611 8.0

SECOND FLOOR

201 - 3' - 0" 7' - 0" F HM 1.2 HM 20 MIN - C4 / A-611 F4 / A-611 I4 / A-611 13.0

202 - 3' - 0" 7' - 0" F HM 1.1 HM - 45 C1 / A-611 F1 / A-611 I1 / A-611 19.0 FOR BID OPTION USE ALTERNATE DOOR HW SET # 36.0

DOOR AND FRAME LEGEND

FINISH

FF-1* FACTORY FINISHED

PE-1** PAINT-EPOXY

MATERIAL

AL ALUMINUM

HM HOLLOW METAL

WD WOOD

SIZE

- SINGLE DOOR

PR PAIR OF DOORS

UPR UNEQUAL PAIR

*REFERENCE DOOR OR FRAME SPECIFICATION

**FIELD APPLY PER PAINT SPECIFICATION FOR

APPLICABLE SUBSTRATE AND EXPOSURE.

(DOOR FRAME)

TYPE A B

1.1

1.2 2" 4"

(FLUSH PANEL)

TYPE DESCRIPTION

F-V VAULT

F-IN FLUSH PANEL INSULATED

F FLUSH PANEL

(FULL LIGHT)

TYPE DESCRIPTION A B D #

FL FULL LITE PANEL 6" 10" 8" 2

FL-IN FULL LITE PANEL

INSULATED

6" 10" 8" 2

(NARROW LIGHT)

TYPE DESCRIPTION A B C D #

NL NARROW LITE 6" 43" 24" 4" 1

(OVERHEAD)

TYPE DESCRIPTION

OH-C

OH-S COILING SECURITY SHUTTER

(FRAME WITH HALF SIDELITE)

TYPE A B E F #

10.1 2" 2" 36" 2

CONTRACTOR SHALL PROVIDE ALTERNATE HARDWARE SET

FOR ACCESS CONTROL BID OPTION

BID OPTIONS: THIS SHEET IS AFFECTED BY BID OPTIONS TO THE

PROJECT. REFER TO SPECIFICATION 01 11 00 FOR ADDITIONAL

INFORMATION.

D

A 05/23/19 JT KY TYPE B-1 SUBMITTAL

B 08/01/19 JT KY TYPE B-2 SUBMITTAL

C 01/03/20 JT BK TYPE B-3 SUBMITTAL

D 10/20/20 JT BK ADDENDUM 3

102554_ - Sheet - A-404 - ENLARGED PLANS - OFFICE AREA & TMO
102554_ - Sheet - A-601 - DOOR SCHEDULE

File details come from the government source that posted it. Updated .