Q and A Addendum 07 27Oct2020 102554_ - Sheet - A-353 - SECTION DETAILS.pdf

PDF 2 MB Posted

Attached to
B222 Renovation and Addition
Solicitation number
W912LM20R1003
Issued by

About this file

This solicitation package describes a federal construction contract opportunity for the Renovation and Addition project at the 148th Fighter Wing of the Minnesota Air National Guard in Duluth, Minnesota. The project scope involves constructing an addition to the existing base supply facility to accommodate administrative and warehouse functions, replacing building systems, and repairing the metal roof and brick facade. The contract is a firm-fixed-price design-bid-build contract with a performance period of 540 days. The estimated value is between $5-10 million. The NAICS code is 236220 and it is set aside for small businesses with a size standard of $39.5 million. The pre-proposal conference is scheduled for October 7th and questions are due by October 26th, with proposals due on October 29th. The source selection will be conducted according to FAR Part 15 using best value tradeoff with past performance and price as evaluation factors.

View the file

Other files

File Type Posted
Addendum 09.doc DOC document
B 08 W912LM20R1003 Amendment 01 B222 Renovation and Addition.pdf PDF
Addendum 08.doc DOC document
Q and A Addendum 07 27Oct2020 08 71 00.pdf PDF
Addendum 07.doc DOC document
Q and A Addendum 07 27Oct2020 102554_ - Sheet - AD010 - GROUND FLOOR DEMOLITION PLAN.pdf PDF
Q and A Addendum 07 27Oct2020 08 11 13.pdf PDF
Q and A Addendum 07 27Oct2020 08 81 00.pdf PDF
Q and A Addendum 07 27Oct2020 08 51 13.pdf PDF
Q and A Addendum 07_Structural.pdf PDF
B222_2007_ExistingWindowInformation.pdf PDF
222-1984-84005-Addition to Engine Shop.pdf PDF
222-1976-Original Construction.pdf PDF
B222_2007_Renovation.pdf PDF
Addendum 05 and 06.doc DOC document
Q and A Addendum 05 09 29 00 26OCT20.pdf PDF
Q and A Addendum 05 08 33 13 26OCT20.pdf PDF
Q and A Addendum 03 Architecture.pdf PDF
Addendum 03 and 04.doc DOC document
Q and A Addendum 01_02 (08 71 00).pdf PDF
Q and A Addendum 01_02 (07 05 23).pdf PDF
Q and A Addendum 01_02 (102554_Elec_PanelboardSchedules_Add01).pdf PDF
Addendum 01 and 02.doc DOC document
Q and A Addendum 01_02 (07 27 10.00 10).pdf PDF
Q and A Addendum 01_02 (08 81 00).pdf PDF
Q and A Addendum 01_02 (14 21 23).pdf PDF
Preproposal Conference.pdf PDF
MATOC Preproposal Conference.pdf PDF
B222 Site visit.pdf PDF
B 04 DB Wage Det 28 Sep.pdf PDF
EXHIBIT A Ld.doc DOC document
EXHIBIT B Ld.doc DOC document
148FW Form 66.pdf PDF
EXHIBIT_C_-_Reference_Questionnaire_Package NEW Ld.docx DOCX document
B 08 W912LM20R1003 B222 Renovation and Addition.pdf PDF
Exhibit D_Letter of Commitment Ld.docx DOCX document
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B

ROOF PANELS

60 MIL. AIR VAPOR

BARRIER

PANEL CLIP

BEARING PLATE

5/8" OSB

6" OF RIGID

INSULATION (R-35 MIN)

CONT. BENT ANGLE

RE: STRUCTURAL

FILL DECK FLUTES WITH

LOOSE BATT INSULATION

NEW ROOF DECK

EXISTING

ROOF DECK

EXISTING RIGID

INSULATION

EXISTING

5/8" OSB

EXISTING ROOF

PANELS

EXISTING ADAL

EXITING NOMINAL

12" CMU FACE BRICK,

MATCH ADJACENT

RIGID INSULATION,

MATCH ADJACENT

B

ROOFGRIP

(2 PER CLIP)

PANEL CLIP

WEBBED MASTIC

(UNDER CLIP)

5/8" OSB

6" OF RIGID

INSULATION (R-35 MIN)

6 MIL. AIR VAPOR

BARRIER

ROOF STRUCTURE

8" NOM. CMU

1 1/2" RIGID INSULATION

BRICK VENEER, SUPPORT

NEW TOP OF BRICK

FILL VOID WITH

SEALANT

PRE FINISHED METAL

FLASHING EXTEND UNDER

EXISTING METAL ROOF TO

ON TOP OF NEW METAL

ROOF

CONT. CHANNEL

RE: STRUCTURAL

CONTINUOUS CLEAT

RIVET (1 PER BATTEN)

BULB-TITE (2 PER

PANEL, DO NOT INSTALL

INTO BATTEN)

TURN PANEL END UP TYP.,

TO PROVIDE ADDITIONAL

MOISTURE PROTECTION

WEBBED MASTIC

MYLAR COATED TAPE

FOAM AND METAL CLOSURE

EXISTING ADAL

EXISTING STANDING SEAM METAL ROOF

MIN. 4"

INSTALL NEW AIR BARRIER AND NEW SHEET METAL

FLASHING MINIMUM 6" UNDER EXISTING METAL ROOF. SET

NEW FLASHING IN CONTINUOUS SEALANT AND FASTEN

WITH EXPOSED FASTENERS FROM ABOVE SPACE AT 12"

ON CENTER. IF EXISTING CONDITIONS DO NOT ALLOW

FOR INSTALLING AIR BARRIER AND FLASHING UNDER

EXISTING ROOFING NOTIFY ARCHITECT.

FILL VOID WITH

FIBERGLASS

BATT

INSULATION

I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.

ROBERT J. KENNALEY

DATE: 10/27/20 LIC. NO. 54022

date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

no. date descriptionby ckd

1 1312111098765432

I

H

G

F

E

D

C

B

A

B222 RENOVATION AND ADAL

xxx

US NATIONAL GUARD BUREAU

MN ANG, 148TH FIGHTER WING

DULUTH, MINNESOTA

8201 NORMAN CENTER DR.

BLOOMINGTON, MN 55437

763-277-4676

102554

D

102554_A_CENTRAL.RVT

A-353

SECTION DETAILS

08/01/19

J. TOP B. KENNALEY

L. SLEDGE

SCALE: 3" = 1'-0"G1

SECTION DETAIL AT EXISTING AND NEW ROOF

0 3" 6" 9" 0 3" 6" 9"

SCALE: 3" = 1'-0"G8

SECTION DETAIL AT EXISTING AND NEW ROOF

D A 05/23/19 JT KY TYPE B-1 SUBMITTAL

B 08/01/19 JT KY TYPE B-2 SUBMITTAL

C 01/03/20 JT BK TYPE B-3 SUBMITTAL

D 10/27/20 JT BK ADDENDUM 7