Q and A Addendum 01_02 (08 71 00).pdf

PDF 68 KB Posted

Attached to
B222 Renovation and Addition Federal contract opportunity
Solicitation number
W912LM20R1003
Issued by
Department of the Army Minnesota Army National Guard

About this file

This solicitation is seeking proposals for a firm fixed-price construction contract valued between $5-10 million to renovate and add to an existing base supply facility at Duluth Air National Guard Base in Minnesota. The scope of work includes constructing an addition, repairing exterior elements, reconfiguring interior partitions, and replacing mechanical and electrical systems. The facility is to be designed to permanent construction standards and incorporate special requirements like matching brick and metal roofing. The project also includes options for communications cabling, a dock leveler, flooring, security systems, and access control. The performance period is 540 days from notice to proceed. The pre-proposal conference is October 7 and questions are due by October 26. Proposals are due October 29 and will be evaluated based on past performance and price. The North American Industry Classification System code is 236220 and it is set aside for small businesses under $39.5 million.

View the file

Other files for this federal contract opportunity

Other files attached to B222 Renovation and Addition, newest first.
File Type Posted
Addendum 09.doc DOC document
B 08 W912LM20R1003 Amendment 01 B222 Renovation and Addition.pdf PDF
Addendum 08.doc DOC document
Q and A Addendum 07 27Oct2020 08 71 00.pdf PDF
Q and A Addendum 07 27Oct2020 08 51 13.pdf PDF
Addendum 07.doc DOC document
Q and A Addendum 07 27Oct2020 08 81 00.pdf PDF
Q and A Addendum 07 27Oct2020 102554_ - Sheet - AD010 - GROUND FLOOR DEMOLITION PLAN.pdf PDF
Q and A Addendum 07 27Oct2020 08 11 13.pdf PDF
Q and A Addendum 07_Structural.pdf PDF
Q and A Addendum 07 27Oct2020 102554_ - Sheet - A-353 - SECTION DETAILS.pdf PDF
B222_2007_ExistingWindowInformation.pdf PDF
222-1976-Original Construction.pdf PDF
222-1984-84005-Addition to Engine Shop.pdf PDF
B222_2007_Renovation.pdf PDF
Q and A Addendum 05 09 29 00 26OCT20.pdf PDF
Addendum 05 and 06.doc DOC document
Q and A Addendum 05 08 33 13 26OCT20.pdf PDF
Q and A Addendum 03 Architecture.pdf PDF
Addendum 03 and 04.doc DOC document
Q and A Addendum 01_02 (102554_Elec_PanelboardSchedules_Add01).pdf PDF
Q and A Addendum 01_02 (07 27 10.00 10).pdf PDF
Addendum 01 and 02.doc DOC document
Q and A Addendum 01_02 (07 05 23).pdf PDF
Q and A Addendum 01_02 (08 81 00).pdf PDF
Q and A Addendum 01_02 (14 21 23).pdf PDF
Preproposal Conference.pdf PDF
MATOC Preproposal Conference.pdf PDF
B222 Site visit.pdf PDF
B 04 DB Wage Det 28 Sep.pdf PDF
EXHIBIT_C_-_Reference_Questionnaire_Package NEW Ld.docx DOCX document
EXHIBIT A Ld.doc DOC document
148FW Form 66.pdf PDF
EXHIBIT B Ld.doc DOC document
B 08 W912LM20R1003 B222 Renovation and Addition.pdf PDF
Exhibit D_Letter of Commitment Ld.docx DOCX document
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Renovate ADAL B222 102554 Duluth Air National Guard Base, Minnesota

SECTION 08 71 00

DOOR HARDWARE

02/16

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this Specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM E283 (2004; R 2012) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

ASTM F883 (2013) Padlocks

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.1 (2016) Butts and Hinges

ANSI/BHMA A156.10 (2017) Power Operated Pedestrian Doors

ANSI/BHMA A156.13 (2017) Mortise Locks & Latches Series 1000

ANSI/BHMA A156.15 (2015) Release Devices Closer Holder, Electromagnetic and Electromechanical

ANSI/BHMA A156.16 (2018) Auxiliary Hardware

ANSI/BHMA A156.18 (2016) Materials and Finishes

ANSI/BHMA A156.19 (2013) Power Assist & Low Energy Power Operated Doors

ANSI/BHMA A156.2 (2017) Bored and Preassembled Locks and Latches

ANSI/BHMA A156.21 (2014) Thresholds

ANSI/BHMA A156.22 (2017) Door Gasketing and Edge Seal Systems

ANSI/BHMA A156.23 (2010) Electromagnetic Locks

ANSI/BHMA A156.24 (2012) Delayed Egress Locking Systems

ANSI/BHMA A156.25 (2013) Electrified Locking Devices

ANSI/BHMA A156.27 (2011) Power and Manual Operated Revolving Pedestrian Doors

ANSI/BHMA A156.29 (2012) Exit Locks, Exit Alarms, Alarms for

SECTION 08 71 00 Page 1

Exit Devices

ANSI/BHMA A156.3 (2014) Exit Devices

ANSI/BHMA A156.30 (2014) High Security Cylinders

ANSI/BHMA A156.31 (2013) Electric Strikes and Frame Mounted Actuators

ANSI/BHMA A156.4 (2013) Door Controls - Closers

ANSI/BHMA A156.5 (2014) Cylinder and Input Devices for Locks

ANSI/BHMA A156.6 (2015) Architectural Door Trim

ANSI/BHMA A156.7 (2016) Template Hinge Dimensions

ANSI/BHMA A156.8 (2015) Door Controls - Overhead Stops and Holders

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 101 (2018; TIA 18-1; TIA 18-2; TIA 18-3) Life Safety Code

NFPA 252 (2017) Standard Methods of Fire Tests of Door Assemblies

NFPA 70 (2017; ERTA 1-2 2017; TIA 17-1; TIA 17-2;

TIA 17-3; TIA 17-4; TIA 17-5; TIA 17-6;

TIA 17-7; TIA 17-8; TIA 17-9; TIA 17-10;

TIA 17-11; TIA 17-12; TIA 17-13; TIA

17-14; TIA 17-15; TIA 17-16; TIA 17-17 )

National Electrical Code

NFPA 72 (2016; Errata 1 2018) National Fire Alarm and Signaling Code

NFPA 80 (2016; TIA 16-1) Standard for Fire Doors and Other Opening Protectives

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines

UNDERWRITERS LABORATORIES (UL)

UL Bld Mat Dir (updated continuously online) Building Materials Directory

SECTION 08 71 00 Page 2

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Manufacturer's Detail Drawings; G

Verification of Existing Conditions; G

Hardware Schedule; G

Keying System; G

SD-03 Product Data

Hardware Items; G

SD-08 Manufacturer's Instructions

Installation

SD-10 Operation and Maintenance Data

Hardware Schedule Items, Data Package 1; G

SD-11 Closeout Submittals

Key Bitting

1.3 SHOP DRAWINGS

Submit manufacturer's Detail Drawings indicating all hardware assembly components and interface with adjacent construction. Indicate power components and wiring coordination for electrified hardware. Base Shop Drawings on verified field measurements and include verification of existing conditions.

1.4 PRODUCT DATA

Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.

1.5 HARDWARE SCHEDULE

Prepare and submit hardware schedule in the following form:

Provide all hardware and construction (temporary) cores required to secure buildings, utility access and related work throughout the construction period. Provide construction cores with a bright color on their exposed face to ease of identification. During construction, the Contractor shall meet with representatives of the Contracting Officer, Public Works Lock

SECTION 08 71 00 Page 3

Shop, and the user to develop a keying schedule. Submit Schedule to Contracting Officer for approval. Provide final keying and combinations as performed by a licensed, bonded locksmith approved by the Contracting Officer. Upon acceptance of the facility for occupancy, replace construction cores with final cores in the presence of the government inspector and a Public Works locksmith, test each lock for proper operation and deliver any permanent or control keys to the inspector.

Prior to core change out, provide the Government, by security shipment, with keys tagged with identifying labels in the quantities indicated.

1.6 KEY BITTING CHART REQUIREMENTS

1.6.1 Requirements

Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:

a. Complete listing of all keys (e.g., AA1 and AA2).

b. Complete listing of all key cuts (AA1-123456, AA2-123458).

c. Tabulation showing which key fits which door.

d. Copy of floor plan showing doors and door numbers.

e. Listing of 20 percent more key cuts than are presently required in each master system.

1.7 QUALITY ASSURANCE

1.7.1 Hardware Manufacturers and Modifications

Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.

1.7.2 Key Shop Drawings Coordination Meeting

Prior to the submission of the Key Shop Drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.

1.8 DELIVERY, STORAGE, AND HANDLING

Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on Hardware Schedule.

Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.

PART 2 PRODUCTS

2.1 TEMPLATE HARDWARE

Hardware applied to metal prefinished doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.

SECTION 08 71 00 Page 4

2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS

Provide all hardware necessary to meet the requirements of NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in Paragraph "Hardware Schedule". Provide Underwriters Laboratories, Inc., labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.

2.3 HARDWARE ITEMS

Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover. Coordinate electrified door hardware components with corresponding components specified in Division 28 ELECTRONIC SECURITY SYSTEMS (ESS).

2.3.1 Hinges

Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inches unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.

2.3.2 Locks and Latches

Locks and latches will be compatible with those in current use at the Site. To the maximum extent possible, locksets, latch sets and deadlocks, and all components thereof, including cylinders and removable cores, shall be the products of a single manufacturer. Bored lock and latch sets are preferred. Use mortise type locks only for restoration work on existing historic type structures, as approved by PW. Lock fronts for double-acting doors shall be furnished with wrought boxes.

a. At exterior locations provide locksets of full stainless steel Type 302 or 304 construction including fronts, strike, escutcheons, knobs, bolts and all interior working parts. Marine Grade I, fully non-ferrous.

b. In non-air-conditioned interior environments or humid interior environments, provide interior locksets on the same Marine Grade I, fully non-ferrous as exterior locksets.

2.3.2.1 Mortise Locks and Latches

Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2. Use raised, beveled escutcheon plate as existing. Match knob type unless lever-type knobs are required for handicapped accessibility. The following brand mortise locksets are presently in use: Provide mortise locks with escutcheons not less than 7 by 2-1/4 inches with a bushing at least 1/4-inch long. Cut escutcheons to fit cylinders and provide trim items with straight, beveled, or smoothly rounded sides, corners, and edges. Provide knobs and roses of mortise locks with screwless shanks and no exposed screws.

SECTION 08 71 00 Page 5

2.3.2.2 Bored Locks and Latches

Bored type locks and latches for doors 1-3/8 inches thick and over shall have adjustable bevel fronts or otherwise conform to the shape of the door. The following brand cylindrical locksets are presently in use:

2.3.3 Exit Devices

Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices.

Use stainless steel base metal with plated finishes. Also include stainless steel fasteners and screws.

2.3.4 Exit Locks With Alarm

Provide in accordance with ANSI/BHMA A156.3 and ANSI/BHMA A156.29 , Type E0431 (with full width horizontal actuating bar) for single doors; Type E0431 (with actuating bar) or E0471 (with actuating bar and top and bottom bolts, both leaves active) for pairs of doors, unless otherwise specified.

Provide terminals for connection to remote indicating panel. Provide door alarms integrated with the fire alarm system in accordance with

NFPA 72 .

2.3.5 Cylinders and Cores

Provide cylinders and cores for new locks, including locks provided under other sections of this Specification. Provide cores that have six pin tumblers factory set using the A-2 system. Keyway is to be H2. To the maximum extent possible, Interchangeable Cores (I/C) shall be the product of a single manufacturer as listed below:

a. Corbin Russwin.

b. KSP (Killen Security Products) 1-800-KSP-KEYS (Interchangeable with existing systems and equipment).

2.3.5.1 High Security Cylinders

Provide in accordance with ANSI/BHMA A156.30 , security level A for all high security cylinder components.

2.3.6 Push Button Mechanisms

Provide in accordance with ANSI/BHMA A156.5 , Grade 1.

2.3.7 Electrified Hardware

Comply with the requirements of NFPA 70 for wiring of electrified hardware.

2.3.7.1 Electric Strikes and Frame Mounted Actuators

Provide in accordance with ANSI/BHMA A156.31 , Grade 1. Provide electric strikes and actuators as required to meet operational requirements.

Provide electric strikes that remain secure during power failure. Provide strikes and actuators with a minimum opening force of 2300 pounds.

SECTION 08 71 00 Page 6

Provide facility interface devices that use direct current (dc) power to energize the solenoids. Provide electric strikes and actuators that incorporate end-of-line resistors to facilitate line supervision by the system. If not incorporated into the electric strike or local controller, provide metal oxide resistors (MOVs) to protect the controller from reverse current surges.

2.3.7.1.1 Solenoid

Provide actuating solenoid for strikes and actuators that are rated for continuous duty, cannot dissipate more than 12 Watts and must operate on 12 or 24 Volts dc. Inrush current cannot exceed 1 ampere and the holding current cannot be greater than 500 milliamperes. Actuating solenoid must move from fully secure to fully open positions in less than 500 milliseconds.

2.3.7.1.2 Signal Switches

Provide strikes and actuators with signal switches to indicate to the system when the bolt is not engaged or the strike mechanism is unlocked.

Signal switches must report a forced entry to the system.

2.3.7.1.3 Tamper Resistance

Provide strike guards that prevent tampering with the latch bolt of the locking hardware or the latch bolt keeper of the electric strike. Strike guards to bolt through the door using tamper resistant screws. Provide strike guards made of 1/8-inch thick brass and that are 11-1/14 inches high by 1-5/8 inches wide, with a minimum 5/32-inch wide offset.

2.3.7.1.4 Coordination

Provide electric strikes and actuators of a size, weight and profile compatible with each specified door frame. Field verify installation clearances prior to procurement.

2.3.7.1.5 Mounting Method

Provide electric strikes and actuators suitable for use with single and double doors, with mortise or rim type hardware specified, and for right or left hand mounting as specified. In double door installations, locate the lock in the active leaf and monitor the fixed leaf.

2.3.7.2 Electrified Mortise Locks

Provide in accordance with ANSI/BHMA A156.25 , Grade 1. Provide electrified mortise locks that remain secure during power failure.

Provide facility interface devices that use dc power to energize solenoids. Provide solenoids, resisters, and signal switches in accordance with Paragraph "Electric Strikes and Frame Mounted Actuators".

2.3.7.2.1 Power Transfer Hinges

Provide power transfer hinges with each electrified lock that route power and monitoring signals from the lockset to the door frame. Coordinate power transfer hinges with door frames.

SECTION 08 71 00 Page 7

2.3.7.3 Card Readers and Keypad Access Control Hardware

Provide in accordance with ANSI/BHMA A156.5 and ANSI/BHMA A156.25 , Grade 1 components. Provide devices that are tamper alarmed, tamper and vandal resistant, solid state, and do not contain electronics which could compromise the access control subsystem should the subsystem be attacked.

Provide surface, semi-flush, pedestal, or weatherproof mountable devices as specified for each individual location. Provide swipe through type card readers capable of reading magnetic stripe Keypad type access control cards. Provide keypads that contain an integral 12-digit tactile keyboard with digits arranged in numerical order. Provide keypads that are integrated into the card reader. Coordinate access control hardware with corresponding devices and systems specified in Division 28 ELECTRONIC

SECURITY SYSTEMS (ESS).

2.3.7.4 Power Operated Pedestrian Door Hardware

Provide in accordance with ANSI/BHMA A156.10 , Grade 1.

2.3.7.5 Release Devices

In accordance with ANSI/BHMA A156.15 , Grade 1.

2.3.7.5.1 Closer Holders

Provide header mounted closer holder devices connected by integral releasing to fire detecting devices.

2.3.7.5.2 Release Devices

Provide wall mounted Electromagnetic release devices connected to fire detecting devices.

2.3.7.6 Power Assist and Low Energy Power Operated Doors

Provide in accordance with ANSI/BHMA A156.19 , Grade 1.

2.3.7.7 Electromagnetic Locks

Provide in accordance with ANSI/BHMA A156.23 , Grade 1. Provide electromagnetic locks that do not contain any moving parts and depend solely upon electromagnetism to secure a portal by generating at least 1200 pounds of holding force. The lock must interface with the local processors without external, internal or functional alteration of the local processor. The electromagnetic lock must incorporate an end of line resistor to facilitate line supervision by the system. Provide metal-oxide resistors (MOVs) to protect controllers from reverse current surges, if not incorporated into the electromagnetic lock or local controller.

2.3.7.7.1 Armature

Provide electromagnetic locks with internal circuitry to eliminate residual magnetism and inductive kickback. Provide actuating armature that operates on 12 or 24 Volts dc and cannot dissipate more than 12 Watts. Holding current must be less than 500 milliamperes. Actuating armature must take less than 300 milliseconds to change the status of the lock from fully secure to fully open or fully open to fully secure.

SECTION 08 71 00 Page 8

2.3.7.7.2 Tamper Resistance

Provide lock mechanism encased in hardened guard barriers to deter forced entry.

2.3.7.7.3 Mounting Method

Provide electromagnetic lock suitable for use with single and double door with mortise or rim type hardware and compatible with right or left hand mounting.

2.3.7.8 Delayed Egress Locking System

Provide in accordance with ANSI/BHMA A156.24 , Grade 1.

2.3.7.9 Power and Manual Operated Revolving Pedestrian Doors

Provide in accordance with ANSI/BHMA A156.27 , Grade 1.

2.3.8 Lock Trim

Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.

2.3.8.1 Knobs and Roses

Provide in accordance with ANSI/BHMA A156.2 and ANSI/BHMA A156.13 for knobs, roses, and escutcheons. For unreinforced knobs, roses, and escutcheons, provide a 0.050 inch thickness. For reinforced knobs, roses, and escutcheons, provide an outer shell thickness of 0.035 inch and a combined total thickness of 0.070 inch, except at knob shanks. Provide knob shanks 0.060 inch thick.

2.3.8.2 Lever Handles

Provide lever handles. Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.

2.3.8.3 Texture

Provide knurled or abrasive coated knobs or lever handles for doors which are accessible to blind persons and which lead to dangerous areas.

2.3.9 Keys

Furnish four (4) keys for each lock core KD (keyed different), and four keys for each set KA (keyed alike) to the Public Works Lock Shop for control and issuing. In addition to the keys listed above, furnish four additional key blanks per core KA. Stamp each key with appropriate key control symbol and "U.S. Property - Do Not Duplicate". Key bows must be stamped with key code line ID (example: LA1223, MPA1223, etc.). All Fort Lewis codes are 1 to 4 letters and 1 to 4 numbers. Public Works Lock Shop will provide ID information and Master control number to be used in combinating core. Do not place room number on keys.

SECTION 08 71 00 Page 9

All locks and locksets used on Joint Base Lewis-McChord shall be compatible with the JBLM keying system. All locks, locksets and lockable panic hardware shall be equipped with cylinders with interchangeable cores as listed above. Locks shall be keyed in sets or subsets as scheduled.

Locks shall be furnished with BEST Brand BLUE construction core or BEST plastic core plugs to protect core splines.

a. Locks: 2 change keys per series.

b. Operator keyed sets: 4 keys total per core.

c. SubMaster keys: 5 issued to building key controller.

d. Master keys: 2 issued to Lock Shop Administrator.

2.3.10 Closers

Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, and other features necessary for the particular application.

Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.

Use stainless steel inside bracketed or door mounted closers on exterior doors. On interior doors use closers of 302 or 304 stainless steel or non-ferrous materials. On surface-mounted closers use or apply rust inhibiting finish on all ferrous parts. Also apply this finish on concealed closers.

2.3.10.1 Identification Marking

Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.

2.3.11 Overhead Holders

Provide in accordance with ANSI/BHMA A156.8 .

2.3.12 Door Protection Plates

Provide in accordance with ANSI/BHMA A156.6 .

2.3.12.1 Sizes of Mop and Kick Plates

Kick plates shall be Type J106 plastic, color as indicated, or J102, aluminum, brass or stainless steel as indicated. Width of plates shall be 2 inches less than door width for single doors and 1 inch less for pairs of doors. Height shall be 12 inches, except where the bottom rail is less than 12 inches the plate shall extend to within 1/2 inch of the panel mold or glass bead. Edges of metal plates shall be square. Mop plates shall be Type J107 plastic in color as indicated, J103 aluminum, brass or, stainless steel as indicated. Width of plates shall be 2 inches less than door width for single doors and 1 inch less for pairs of doors. The height shall be 4 inches. Edges of metal plates shall be square.

SECTION 08 71 00 Page 10

2.3.12.2 Edge Guards

Stainless steel, of same height as armor plates. Apply to meeting stiles.

2.3.13 Door Stops and Silencers

Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.

Provide three silencers for each single door, two for each pair.

2.3.14 Padlocks

Provide in accordance with ASTM F883.

2.3.15 Thresholds

Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.

2.3.16 Weatherstripping Gasketing

Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in Paragraph "Hardware Schedule".

Provide a set to include head and jamb seals and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed 0.04 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:

2.3.16.1 Extruded Aluminum Retainers

Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear (natural) anodized aluminum.

2.3.16.2 Spring Tension Type

Spring stainless steel not less than 0.008 inch thick.

2.3.17 Rain Drips

Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, factory painted finish.

Provide the manufacturer's full range of color choices to the Contracting Officer for color selection. Provide rain drips with a 4 inch overlap on each side of each exterior door that is not protected by an awning, roof, eave or other horizontal projection. Set drips in sealant and fasten with stainless steel screws.

2.3.17.1 Door Rain Drips

Approximately 1-1/2 inches high by 5/8 inch projection. Align bottom with bottom edge of door.

2.3.17.2 Overhead Rain Drips

Approximately 1-1/2 inches high by 2-1/2 inch projection. Align bottom with door frame rabbet.

SECTION 08 71 00 Page 11

2.3.18 Special Tools

Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.

2.4 FASTENERS

Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.

2.5 FINISHES

Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide hinges for exterior doors in stainless steel with BHMA 630 finish.

Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish. Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.

2.6 KEY CABINET AND CONTROL SYSTEM

Provide in accordance with ANSI/BHMA A156.5 , ANSI/BHMA A156.5 , Key control storage system shall conform to ANSI/BHMA A156.5 , type as indicated, and shall be properly labeled for key identification. Set up, identification labeling and location of the key control storage shall be as directed at the Predelivery Conference.

PART 3 EXECUTION

3.1 INSTALLATION

Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.

Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.

3.1.1 Weatherstripping Installation

Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.

3.1.1.1 Stop Applied Weatherstripping

Fasten in place with color matched sheet metal screws not more than 9 inches on center after doors and frames have been finish painted.

3.1.1.2 Interlocking Type Weatherstripping

Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inches on center.

SECTION 08 71 00 Page 12

3.1.1.3 Spring Tension Type Weatherstripping

Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inches on center.

3.1.2 Threshold Installation

Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws. For aluminum thresholds placed on top of concrete surfaces, coat the underside surfaces that are in contact with the concrete with fluid applied waterproofing as a separation measure prior to placement.

3.2 FIRE DOORS AND EXIT DOORS

Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door assemblies.

3.3 HARDWARE LOCATIONS

Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.

a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.

b. Mop Plates: Bottom flush with bottom of door.

3.4 KEY CABINET AND CONTROL SYSTEM

Locate where directed. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Provide complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.

3.5 FIELD QUALITY CONTROL

After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.

3.6 HARDWARE SETS

SECTION 08 71 00 Page 13

Provide Deliver Hardware templates and hardware, except field applied hardware.

a. The door hardware sets represent the design intent and direction of the owner and architect. They are a guideline only and should not be considered a detailed hardware schedule. Discrepancies, conflicting hardware and missing items should be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality.

b. The supplier is responsible for handing and sizing all products as listed in the door hardware sets. Quantities listed are for each pair of doors, or for each single door.

c. Products listed in the Door Hardware Sets must meet the requirements described in the specification section. Products listed in the hardware sets are given as a basis of design.

d. Manufacturer's Abbreviations:

(1) MK - McKinney

(2) RO - Rockwood

(3) VD - Von Duprin

(4) BE - dormakaba Best

(5) KA - Kaba Ilco

(6) AH - Architectural Builders Hardware

(7) SA - SARGENT

(8) PE - Pemko

(9) ZE - Zero International Inc

(10) ST - Stanley Works

(11) SU - Securitron

(12) OT - Other

Hardware Sets

Set: 1.0 Doors: 132A Description: Single Exterior Stair

3 Hinge (heavy weight) T4A3386 x NRP 4-1/2" x 4-1/2" US32D MK 1 Rim Exit Device 99L-NL 06 996L-NL US26D VD 1 Rim Cylinder 12E-72 626 BE 1 Door Closer 281 CPS EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Threshold 2705AT PE 1 Sweep 315CN PE 1 Rain Guard 346C PE 1 Gasketing 2891AS (Head & Jambs) PE

Notes: Install perimeter seal prior to closer, exit device, and strike.

Special templating required. Prior to submitting/ordering hardware, hardware supplier to survey existing openings to confirm compatibility of new hardware with existing frames. Submit hardware compatible with existing openings that will meet design intent. Prep, patch, and repair existing frames as necessary to accommodate new hardware.

SECTION 08 71 00 Page 14

Set: 2.0 Doors: 101A, 120A Description: Single Exterior

3 Hinge (heavy weight) T4A3386 x NRP 4-1/2" x 4-1/2" US32D MK 1 Rim Exit Device 99L 06 996L US26D VD 1 Rim Cylinder 12E-72 626 BE 1 Door Closer 281 P10 EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Door Stop 481H US26D RO 1 Threshold 2705AT PE 1 Sweep 315CN PE 1 Rain Guard 346C PE 1 Gasketing 2891AS (Head & Jambs) PE 1 Latch Protector 320-RKW US32D RO

Notes: Install perimeter seal prior to closer, exit device, and strike.

Special templating required. Prior to submitting/ordering hardware, hardware supplier to survey existing openings to confirm compatibility of new hardware with existing frames. Submit hardware compatible with existing openings that will meet design intent. Prep, patch, and repair existing frames as necessary to accommodate new hardware.

Set: 3.0 Doors: 130A, 134A, 137B, 137F Description: Single Exterior

3 Hinge (heavy weight) T4A3386 x NRP 4-1/2" x 4-1/2" US32D MK 1 Storeroom Lock 45H7D 15J 630 BE 1 Door Closer 281 CPS EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Threshold 2705AT PE 1 Gasketing 2891AS (Head) PE 1 Gasketing 290AS (Jambs) PE 1 Sweep 315CN PE 1 Rain Guard 346C PE 1 Latch Protector 320-RKW US32D RO

Notes: Install perimeter seal prior to closer. Special templating required. Prior to submitting/ordering hardware, hardware supplier to survey existing openings to confirm compatibility of new hardware with existing frames. Submit hardware compatible with existing openings that will meet design intent. Prep, patch, and repair existing frames as necessary to accommodate new hardware.

Set: 4.0 Doors: 119A Description: Pair Exterior Elec.

6 Hinge (heavy weight) T4A3386 x NRP 4-1/2" x 4-1/2" US32D MK 1 Mullion KR4954 SP28 VD 1 Rim Exit Device 99L-NL 06 996L-NL US26D VD 1 Rim Exit Device 99EO US26D VD 1 Rim Cylinder 12E-72 626 BE 2 Door Closer 281 CPS EN SA 2 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Threshold 2705AT PE 1 Gasketing 2891AS (Head) PE 1 Gasketing 290AS (Jambs) PE

SECTION 08 71 00 Page 15

2 Sweep 315CN PE 1 Rain Guard 346C PE 1 Mullion Gasketing 5110BL PE 1 Astragal 18041CNB (Both Leaves) PE

Notes: Install perimeter seal prior to closer. Prior to submitting/ordering hardware, hardware supplier to survey existing openings to confirm compatibility of new hardware with existing frames.

Submit hardware compatible with existing openings that will meet design intent. Prep, patch, and repair existing frames as necessary to accommodate new hardware.

Set: 5.0 Doors: 101B, 120B Description: Single Vest.

3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" US26D MK 1 Push Plate 70F US32D RO 1 Door Pull BF167 Mtg-Type 12XHD US32D RO 1 Door Closer 281 P10 EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 3 Silencer 608-RKW RO

Notes: Prior to submitting/ordering hardware, hardware supplier to survey existing openings to confirm compatibility of new hardware with existing frames. Submit hardware compatible with existing openings that will meet design intent. Prep, patch, and repair existing frames as necessary to accommodate new hardware.

Set: 6.0 Doors: 117A Description: Pair Conference

6 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Cylindrical Lock 9K37R 15D S3 626 BE 2 Door Closer 351 PS EN SA 2 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO

Notes: Perimeter seals, door bottom, and threshold (if required) by acoustic door manufacturer. Prior to submitting/ordering hardware, hardware supplier to survey existing openings to confirm compatibility of new hardware with existing frames. Submit hardware compatible with existing openings that will meet design intent. Prep, patch, and repair existing frames as necessary to accommodate new hardware.

Set: 7.0 Doors: 129A Description: Pair Vault

6 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Dust Proof Strike 570 US26D RO 1 Keypad Lock 5021 B WL 26D KA 1 Core 1C As Required 626 BE 2 Door Closer 351 CPS EN SA 2 Armor Plate K1050 34" x 2" LDW CSK BEV US32D RO 1 Threshold 1715A PE 2 Sweep 315CN PE

SECTION 08 71 00 Page 16

1 Gasketing S88D PE 1 Astragal 43SP ZE

Notes: Mount astragal on pull side of active leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors.

Operation:

1. Door electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential.

Lockset mechanically locks during power failure with a mechanical key override entry.

2. Egress always free from inside by depressing inside lever.

3. Request to exit switch in lever to signal authorized egress to the access control system.

4. Door position switch to signal door open/closed to the access control system.

Set: 8.0 Doors: 139A Description: Pair Wood Shop Rated

6 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Flush Bolt 2842 US26D RO 1 Classroom Lock 9K37R 15D S3 626 BE 1 Coordinator 2672 x Brackets as Reqd. Black RO 2 Door Closer 351 PS EN SA 2 Armor Plate K1050 34" x 2" LDW CSK BEV US32D RO 1 Threshold 1715A PE 1 Sweep 315CN PE 1 Gasketing S88D PE 1 Astragal 43SP ZE

Notes: Mount astragal on pull side of active leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors.

Set: 9.0 Doors: 121A Description: Single Weapons Vault

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Keypad Lock 5021 B WL 26D KA 1 Core 1C As Required 626 BE 1 Door Closer 351 CPS EN SA 1 Armor Plate K1050 34" x 2" LDW CSK BEV US32D RO 1 Threshold 1715A PE 1 Sweep 315CN PE 1 Gasketing S88D PE 1 Latch Protector 320-RKW US32D RO

Set: 10.0 Doors: 118A Description: Single Comm

3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Storeroom Lock 9K37D 15D S3 626 BE 1 Door Closer 351 O EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO

SECTION 08 71 00 Page 17

3 Silencer 608-RKW RO

Set: 11.0 Doors: 128A Description: Single Riser Room Rated

3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Storeroom Lock 9K37D 15D S3 626 BE 1 Door Closer 351 O EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO 1 Gasketing S88D PE

Set: 12.0 Doors: 133A Description: Single Stair Rated (FA)

2 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Hinge (heavy weight) T4A3786 CC8 4-1/2" x 4-1/2" US26D MK 1 Electromechanical Lock 45HW7DEL RQE 15J 626 BE 1 Door Closer 351 O EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO 1 Gasketing S88D PE 1 Power Supply BPS-24-1 SU

Notes: Operation:

1. Door electrically locked with mechanical key override.

2. Egress always free from inside by depressing inside lever.

3. Outside lever becomes unlocked in fire alarm or loss of power.

Set: 13.0 Doors: 201 Description: Single Open Office Rated

3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock 9K37R 15D S3 626 BE 1 Door Closer 351 O EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO 1 Gasketing S88D PE

Set: 14.0 Doors: 103A, 104A, 105A, 106A, 107A, 108A, 109A, 110A, 111A Description: Single Office

3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" US26D MK 1 Entrance Lock 9K37AB 15D S3 626 BE 1 Wall Stop 409 US32D RO

Notes: Perimeter seals, door bottom, and threshold (if required) by acoustic door manufacturer.

Set: 15.0 Doors: 112B Description: Single Orderly Work

3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock 9K37R 15D S3 626 BE

SECTION 08 71 00 Page 18

1 Door Closer 351 PS EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO

Notes: Perimeter seals, door bottom, and threshold (if required) by acoustic door manufacturer.

Set: 16.0 Doors: 115.1A Description: Single Storage

3 Hinge TA2714 x NRP 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock 9K37R 15D S3 626 BE 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO 3 Silencer 608-RKW RO

Set: 17.0 Doors: 131A Description: Single Storage Rated

3 Hinge TA2714 x NRP 4-1/2" x 4-1/2" US26D MK 1 Storeroom Lock 9K37D 15D S3 626 BE 1 Door Closer 281 P10 EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO 1 Gasketing S88D PE

Set: 18.0 Doors: 135A, 136A Description: Single Combustible Storage Rated

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Rim Exit Device 99L-NL 06 996L-NL US26D VD 1 Rim Cylinder 12E-72 626 BE 1 Door Closer 351 CPS EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Gasketing S88D PE

Set: 19.0 Doors: 202 Description: Single SIPR

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Keypad Lock 5021 B WL 26D KA 1 Core 1C As Required 626 BE 1 Door Closer 351 P10 EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO

Notes: Perimeter seals, door bottom, and threshold (if required) by acoustic door manufacturer.

Set: 20.0 Doors: 115A Description: Single Break

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock 9K37R 15D S3 626 BE 1 Door Closer 351 CPS EN SA

SECTION 08 71 00 Page 19

1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 3 Silencer 608-RKW RO

Set: 21.0 Doors: 115C Description: Single Break

3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock 9K37R 15D S3 626 BE 1 Door Closer 351 O EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO 3 Silencer 608-RKW RO

Set: 22.0 Doors: 114A Description: Single Clothing Rated

3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock 9K37R 15D S3 626 BE 1 Surface Overhead Stop 902xA US32D AH 1 Door Closer 351 O EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Gasketing S88D PE

Set: 23.0 Doors: 113A, 130C Description: Single Warehouse

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Keypad Lock 5021 B WL 26D KA 1 Core 1C As Required 626 BE 1 Door Closer 351 PS EN SA 1 Armor Plate K1050 34" x 2" LDW CSK BEV US32D RO 3 Silencer 608-RKW RO

Set: 24.0 Doors: 112A Description: Single Warehouse Rated

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock 9K37R 15D S3 626 BE 1 Door Closer 351 P10 EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Threshold 1715A PE 1 Sweep 315CN PE 1 Gasketing S88D PE

Set: 25.0 Doors: 138A, 138B, 138C Description: Single TMO Rated

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock 9K37R 15D S3 626 BE 1 Door Closer 351 PS EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Gasketing S88D PE

Set: 26.0

SECTION 08 71 00 Page 20

Doors: 124A, 126A Description: Single Restroom

3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" US26D MK 1 Push Plate 70F US32D RO 1 Pull Plate BF 111 x 70C US32D RO 1 Door Closer 351 O EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO 3 Silencer 608-RKW RO

Set: 27.0 Doors: 123A Description: Single Janitor

3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Storeroom Lock 9K37D 15D S3 626 BE 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO 3 Silencer 608-RKW RO

Set: 28.0 Doors: 133B Description: Pair Open Office

6 Hinge (heavy weight) T4A3786xNRP 5" x 4-1/2" US26D MK 1 Flush Bolt 2842 US26D RO 1 Cylindrical Lock 9K37R 15D S3 626 BE 1 Coordinator 2672 x Brackets as Reqd. Black RO 2 Door Closer 351 CPS EN SA 2 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Threshold 1715A PE 2 Sweep 315CN PE 1 Gasketing S88D PE 1 Astragal 43SP ZE

Notes: Mount astragal on pull side of active leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors.

Set: 29.0 Doors: 122B, 134B Description: Pair Open Office/Corridor Rated

6 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Flush Bolt 2842 US26D RO 1 Cylindrical Lock 9K37R 15D S3 626 BE 1 Coordinator 2672 x Brackets as Reqd. Black RO 2 Door Closer 351 CPS EN SA 2 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Threshold 1715A PE 2 Sweep 315CN PE 1 Gasketing S88D PE 1 Astragal 43SP ZE

Notes: Mount astragal on pull side of active leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors.

Set: 30.0 Doors: 122C

SECTION 08 71 00 Page 21

Description: Single Corridor Rated

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Classroom Lock 9K37R 15D S3 626 BE 1 Door Closer 351 CPS EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Gasketing S88D PE

Set: 31.0 Doors: 122A Description: Pair Corridor Rated

6 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Flush Bolt 2842 US26D RO 1 Classroom Lock 9K37R 15D S3 626 BE 1 Coordinator 2672 x Brackets as Reqd. Black RO 2 Door Closer 351 P10 EN SA 2 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 2 Wall Stop 406 US26D RO 1 Threshold 1715A PE 2 Sweep 315CN PE 1 Gasketing S88D PE 1 Astragal 43SP ZE

Notes: Mount astragal on pull side of active leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors.

Set: 32.0 Doors: 116A Description: Single Stair

3 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Cylindrical Lock 9K37R 15D S3 626 BE 1 Door Closer 351 PS EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Gasketing S88D PE

Set: 33.0 Doors: 113B, 114B, 114C, 115B, 121B, 121C, 130B, 130D, 135B, 137A, 137C, 137D, 137E Description: Overhead Coiling

1 Door Hardware Furnished by Door Mfg. 00

Hardware Sets for Alternate:

Set: 34.0 Doors: 121A - ALT Description: Single Weapons (CR)

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Electromechanical Lock 45HW7DEU 15J RQE C 630 BE 1 Door Closer 351 CPS EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Electric Power Transfer EPT-12C PR 1 Wiring Harness WH as Req'd (Door) ST 1 Wiring Harness WH as Req'd (Frame) ST 1 Card Reader By Access Control OT 1 Position Switch By Access Control; Prep by Dr/FR Mfr. OT

SECTION 08 71 00 Page 22

1 Power Supply By Access Control OT

Notes: Operation:

1. Door electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential.

Lockset mechanically locks during power failure with a mechanical key override entry.

2. Egress always free from inside by depressing inside lever.

3. Request to exit switch in lever to signal authorized egress to the access control system.

4. Door position switch to signal door open/closed to the access control system.

Set: 35.0 Doors: 113A - ALT, 130C - ALT Description: Single Warehouse (CR)

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Electromechanical Lock 45HW7DEU 15J RQE C 630 BE 1 Door Closer 351 CPS EN SA 1 Armor Plate K1050 34" x 2" LDW CSK BEV US32D RO 1 Electric Power Transfer EPT-12C PR 1 Wiring Harness WH as Req'd (Door) ST 1 Wiring Harness WH as Req'd (Frame) ST 1 Card Reader By Access Control OT 1 Position Switch By Access Control; Prep by Dr/FR Mfr. OT 1 Power Supply By Access Control OT

Notes: Operation:

1. Door electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential.

Lockset mechanically locks during power failure with a mechanical key override entry.

2. Egress always free from inside by depressing inside lever.

3. Request to exit switch in lever to signal authorized egress to the access control system.

4. Door position switch to signal door open/closed to the access control system.

Set: 36.0 Doors: 202 - ALT Description: Single SIPR (CR)

3 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 1 Electromechanical Lock 45HW7DEU 15J RQE C 630 BE 1 Door Closer 351 P10 EN SA 1 Kick Plate K1050 12" x 2" LDW CSK BEV US32D RO 1 Wall Stop 406 US26D RO 1 Electric Power Transfer EPT-12C PR 1 Wiring Harness WH as Req'd (Door) ST 1 Wiring Harness WH as Req'd (Frame) ST 1 Card Reader By Access Control OT 1 Position Switch By Access Control; Prep by Dr/FR Mfr. OT 1 Power Supply By Access Control OT

Notes: Perimeter seals, door bottom, and threshold (if required) by acoustic door manufacturer.

SECTION 08 71 00 Page 23

Operation:

1. Door electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential.

Lockset mechanically locks during power failure with a mechanical key override entry.

2. Egress always free from inside by depressing inside lever.

3. Request to exit switch in lever to signal authorized egress to the access control system.

4. Door position switch to signal door open/closed to the access control system.

Set: 37.0 Doors: 129A - ALT Description: Pair Vault (CR)

6 Hinge (heavy weight) T4A3786 x NRP 4-1/2" x 4-1/2" US26D MK 2 Flush Bolt 555 US26D RO 1 Electromechanical Lock 45HW7DEU 15J RQE C 630 BE 1 Core 1C As Required 626 BE 2 Door Closer 351 CPS EN SA 2 Armor Plate K1050 34" x 2" LDW CSK BEV US32D RO 1 Threshold 1715A PE 2 Sweep 315CN PE 1 Gasketing S88D PE 1 Astragal 43SP ZE 1 Electric Power Transfer EPT-12C PR 1 Wiring Harness WH as Req'd (Door) ST 1 Wiring Harness WH as Req'd (Frame) ST 1 Card Reader By Access Control OT 2 Position Switch By Access Control; Prep by Dr/FR Mfr. OT 1 Power Supply By Access Control OT

Notes: Mount astragal on pull side of active leaf and size doors for 1/8" clearance between leaves. Paint astragal to match doors.

Operation:

1. Door electrically unlocked or locked during established time zones as programmed by the access control system. When outside lever is locked the card reader grants access upon presentation of a valid credential.

Lockset mechanically locks during power failure with a mechanical key override entry.

2. Egress always free from inside by depressing inside lever.

3. Request to exit switch in lever to signal authorized egress to the access control system.

4. Door position switch to signal door open/closed to the access control system.

-- End of Section --

SECTION 08 71 00 Page 24

File details come from the government source that posted it. Updated .