Addendum 03 and 04.doc

DOC document 33 KB Posted

Attached to
B222 Renovation and Addition Federal contract opportunity
Solicitation number
W912LM20R1003
Issued by
Department of the Army Minnesota Army National Guard

About this file

This document provides details for a federal solicitation seeking construction services. The U.S. Property and Fiscal Office for Minnesota is soliciting a single firm fixed-price contract to renovate and add onto an existing base supply facility at Duluth Air Force Base in Minnesota. Work includes repairing metal flashing and roofs, replacing doors, rehabilitating brick facades, reconfiguring interior spaces, and upgrading building systems. The project budget is between $5-10 million and work must be completed within 540 days. The solicitation is set aside for small businesses and responses are due by October 29, 2020. A pre-proposal conference will be held on October 7 and the source selection process will evaluate past performance and price.

View the file

Other files for this federal contract opportunity

Other files attached to B222 Renovation and Addition, newest first.
File Type Posted
Addendum 09.doc DOC document
B 08 W912LM20R1003 Amendment 01 B222 Renovation and Addition.pdf PDF
Addendum 08.doc DOC document
Q and A Addendum 07 27Oct2020 102554_ - Sheet - AD010 - GROUND FLOOR DEMOLITION PLAN.pdf PDF
Q and A Addendum 07 27Oct2020 08 11 13.pdf PDF
Q and A Addendum 07 27Oct2020 08 81 00.pdf PDF
Q and A Addendum 07_Structural.pdf PDF
Q and A Addendum 07 27Oct2020 102554_ - Sheet - A-353 - SECTION DETAILS.pdf PDF
Q and A Addendum 07 27Oct2020 08 71 00.pdf PDF
Q and A Addendum 07 27Oct2020 08 51 13.pdf PDF
Addendum 07.doc DOC document
222-1984-84005-Addition to Engine Shop.pdf PDF
222-1976-Original Construction.pdf PDF
B222_2007_Renovation.pdf PDF
B222_2007_ExistingWindowInformation.pdf PDF
Addendum 05 and 06.doc DOC document
Q and A Addendum 05 09 29 00 26OCT20.pdf PDF
Q and A Addendum 05 08 33 13 26OCT20.pdf PDF
Q and A Addendum 03 Architecture.pdf PDF
Addendum 01 and 02.doc DOC document
Q and A Addendum 01_02 (07 05 23).pdf PDF
Q and A Addendum 01_02 (08 81 00).pdf PDF
Q and A Addendum 01_02 (14 21 23).pdf PDF
Q and A Addendum 01_02 (08 71 00).pdf PDF
Q and A Addendum 01_02 (102554_Elec_PanelboardSchedules_Add01).pdf PDF
Q and A Addendum 01_02 (07 27 10.00 10).pdf PDF
Preproposal Conference.pdf PDF
MATOC Preproposal Conference.pdf PDF
B222 Site visit.pdf PDF
B 04 DB Wage Det 28 Sep.pdf PDF
B 08 W912LM20R1003 B222 Renovation and Addition.pdf PDF
Exhibit D_Letter of Commitment Ld.docx DOCX document
148FW Form 66.pdf PDF
EXHIBIT B Ld.doc DOC document
EXHIBIT_C_-_Reference_Questionnaire_Package NEW Ld.docx DOCX document
EXHIBIT A Ld.doc DOC document
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTICE OF REQUEST FOR PROPOSAL

ADDENDUM 03 & 04

DATE: 23 Oct 2020

PROJECT TITLE & NUMBER:

REPRENOVATION & ADDITION FOR B222

PN: FMKM112035

1. This addendum is being issued to answer Contractor submitted questions Q1. I'm trying to get pricing out for our customers to bid on this project but I have incomplete concrete specs. In searching the specs and the plans all I could find were a very general concrete spec of 4500 psi with .50 w/c ratio and 6% air. That will definitely not cover all the different applications for concrete this project requires. I expect you will need at least 3 different mix designs. Will you require any fibers, perhaps for the Interior Slab on Grade? " A1. No fibers are required. The interior slab and grade shall be reinforced as shown in the contract documents. All concrete shall have a compressive strength of 4,500 psi Normal Weight per S -001 note 6.A.2.a.

Concrete Footings and Misc. Concrete shall be air entrained. Air content must be between 4.5% and 7.5% per 03 30 53, 2.1.3. 3/4 inch nominal size coarse aggregate for walls or 1-1/2 inches for other concrete per 03 30 53, 2.1.3. Maximum water-cementitious material ratio is 0.50 per 03 30 53, 2.1.3.

Interior Slabs with trowel finish, do not air entrain per S-001 note 6.A.2.b. Per Spec 03 30 53, 2.1.3 air content must be 3% maximum for slabs to receive trowel finish. 3/4 inch maximum nominal size coarse aggregate per 03 30 53, 2.1.3. Maximum water-cementitious material ratio is 0.50 per 03 30 53, 2.1.3.Q2. On sheet S-122 at the new elevator location, is the intent to remove / replace the existing roof system or is all this work to be completed with the existing roofing in place?

Q2. Is the intent to have all 12 door sets shown on X-XXX to receive an STC 45 rating?

A2. STC 45 ratings shall only apply to Doors 129A and 202, see revised architectural drawings in upcoming Addendum 03-04.

Q3. There is not a single vertical dimension on any elevation or detail showing wall or building heights (structural or architectural) . Structural shows steel bearing elevations but that does not provide the information needed. Please provide these dimensions for every condition both interior & exterior, existing & new. For sloping conditions, provide tops of both high & low ends of these locations.

A3. The top of CMU elevations are indicated on sheets A311 and A-312. These elevations along with the structural beam and bearing height information, shown on sheets S-121, S-123, S-131 and S-132, should be followed to determine the quantity of materials that will be needed to construct this addition.

Since the project is an addition to an existing building, several dimensions for the addition will be tied to existing conditions. Where this occurs, existing dimensions will need to be field verified. This could be accomplished during the pre-bid site visit. Several architectural vertical dimensions are included in the drawings, including top of masonry walls, and door and window sizes. If further information is needed, you may consider requesting a copy the existing building drawings, available upon request.

Specifically - Low Roof Framing Plan, S-121. Existing wall along gridline B shall be field verified per Plan Note 4, existing construction documents indicate a top of wall at 115’-8” (+/-). New masonry wall at north end, per S-121, shows a joist bearing elevation of 111’-4”. Joist bearing elevation is equivalent to top of masonry wall as shown in C4/S-322.

High Roof Framing Plan, S-123. Existing wall along gridline B slopes from gridline 3 (high end, existing construction documents indicate a top of wall at 129’-4” (+/-)) to east of gridline 6 (low end, existing construction documents indicate a top of wall at 121’-4” (+/-)). All existing dimensions shall be field verified per Plan Note 4. Joist bearing elevations shown on S-123 are equivalent to top of masonry wall as shown in F1/S-321. Top of CMU elevations are indicated on sheet A-311 and A-312. New High Roof Framing shall match the existing roof slope as indicated in D1/A-202. New top of steel and new masonry elevations shall be field verified with existing construction. New roof framing shall be tied into existing per F4/S-321, F8/S-321 and H4/S-322.

The top of CMU elevations are indicated on sheets A311 and A-312. These elevations along with the structural beam and bearing height information, as outlined above should be followed to determine the quantity of materials that will be needed to construct this addition.

2. This amendment must be acknowledged when submitting your proposal.