Renovation BLDG 125-Mechanical Room - Sheet - M-111 - MECHANICAL ROOM PLAN.pdf

PDF 325 KB Posted

Attached to
Renovate Bldg. 125 Fort Hamilton, Brooklyn, New York
Solicitation number
W912DS23B0022
Issued by

About this file

This document is a mechanical room plan for the renovation of Building 125 at Fort Hamilton in Brooklyn, New York. The plan details the layout of existing and new mechanical equipment in the room, including an existing boiler, new water heater, exhaust louvers, intake and exhaust piping, and branch controllers. Notes specify that final equipment selections and venting requirements are subject to manufacturer recommendations. The related federal contract opportunity is solicitation number W912DS23B0022 issued by the Department of the Army Corps of Engineers Engineering District New York to renovate Building 125 at Fort Hamilton.

View the file

Other files

File Type Posted
C.04.01 Bid Abstract Bldg 125 Final.pdf PDF
A-605 and S-102 S-103 Amd 5.pdf PDF
B.08.03 Amendment 05.pdf PDF
09 06 00 Amd 5.pdf PDF
10 21 13 Amd 5.pdf PDF
E-002 and ED102 Amd 3.pdf PDF
LEED_v4_for_Interior_Design_and_Construction_Checklist B125 Reno Ft Hamilton.pdf PDF
Army_SustainabilityReportCard_2020 B125 Renovation LEED IDC.pdf PDF
Fort Hamilton Planning Charrete.pdf PDF
M-101 thru 107 (rev 02) and 602 (rev 01) Amd 5.pdf PDF
07 27 10 Amd 5.pdf PDF
12 50 00.13 FFE Data Sheet Item Code M4 revised.pdf PDF
01 33 29 Amd 5.pdf PDF
B.08.03 Amendment 04.pdf PDF
B.08.03 Amendment 03.pdf PDF
A-405 20230830.pdf PDF
A-408 20230830.pdf PDF
A-501 20230831.pdf PDF
1AB-101 20230830.pdf PDF
A-605 20230831.pdf PDF
A-101 A-403 A-501 AD-101 AD-403 20230829.pdf PDF
B.08.03 Amendment 02.pdf PDF
A-602 Amendment 2 20230823.pdf PDF
Amendment 2 Mechanical Drawings M102 thru 107 M601 M701.pdf PDF
A-404 Amendment 2 20230824.pdf PDF
A-601 Amendment 2 20230823.pdf PDF
B.08.03 Amendment 01.pdf PDF
B.08.03 Site Visit Sign in sheet_16 Aug 23 (002).jpg JPG image
B.08.03 Invitation for Bid W912DS23B0022.pdf PDF
JA_Hamilton_125_Simplex Signed.pdf PDF
Fort Hamilton Bldg 125-100_PCNT_Specification_07-31-2023.pdf PDF
B.08.03 Invitation for Bid W912DS23B0022.pdf PDF
B125 RTA Complete set R4 07 August 2023.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A1

M-111

B-1

UH-6

ERVU-1

BRANCH

CONTROLLER-2

BRANCH

CONTROLLER-3

EXISTING

BOILER

BRANCH

CONTROLLER-1

EF-2

HP-1 HP-2

DHWH-1

UH-5

P-1

P-2

B-2

"ø

S A

"ø

R A

16"Ø EA

CONCENTRIC INTAKE

AND EXHAUST FOR BOILER

CONCENTRIC

VENT FOR WATER

HEATER

24"Ø OA

B-1

B

BREECHING FROM

EXISTING BOILER TO

REMAIN

EXISTING

CHIMNEY

CHASE

B-1 B-2

EXISTING

BOILER

P-1

P-2

EF-2

18"ø RA

DHWH-1

UH-6

UH-5

BRANCH

CONTROLLER-1

BRANCH

CONTROLLER-2BRANCH

CONTROLLER-3

CONCENTRIC

VENT FOR WATER

HEATER

CONCENTRIC VENT FOR

BOILER

18"ø SA

"ø

R A

B

ERVU-1 EXHAUST LOUVER

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

S

P ro je c ts

\F t_

H a m ilt o n \B ld g R e n o v \C

A D

B

IM

\1

M e c h \T e n z in

-9 r e v is e d f o ld e r\

R e n o v a ti o n B

L D

G

-M e c h a n ic a l R o o m

.r v t

/2

/2

:3

:1

P

M

M-111

M E

C H

A N

IC

A

L R

O O

M P

L A

N

W

A

IN

W R

IG

H

T D

R B

R O

O K

L Y

N N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N

E W

Y O

R K

N

Y

N O

T F

O R

C O

N S

T R

U C

T

IO

N

D e s ig n e r

A u th o r

C h e c k e r

J U

L Y

B L D

G

S T

M A

R

IN

E C

O R

P S

D

IS

T R

IC

T

R E

L O

C A

T

IO

N T

O F

T

F O

R T

H A

M

IL

T O

N N

Y

A

D D

E D

D R

A W

IN

G

F O

R S

P A

T

IA

L R

E F

E R

E N

C E

/2

/2

1/4" = 1'-0"1 Mechanical Room Plan

1. INTAKE AND EXHAUST LAYOUT AND DEPICTION ARE SHOWN FOR REPRESENTATION

AND REFERENCES, THE FINAL PATH SHALL BE COORDINATED WITH EQUIPMENT

MANUFACTURER. FLUE SIZE, FITTINGS, AND MATERIAL SHALL BE AS RECOMMENDED BY

THE BOILER AND WATER HEATER MANUFACTURER.

2. CONCENTRIC VENT FOR BOILER AND WATER HEATER SHOWN HERE ARE FOR

REPRESENTATION AND REFERENCES. SEPARATE DIRECT VENT IS ACCEPTABLE PER

RECOMMENDATION OF BOILER AND WATER HEATER MANUFACTURER.

3. THE INTAKE AND EXHAUST FLUE DEVELOPED MAXIMUM LENGTH SHALL BE

COORDINATED WITH THE FINAL APPROVED BOILER MANUFACTUER; THE FLUE PATH,

SPATIAL CLEARANCES, AND ITS WALL PENETRATION SHALL BE PER BOILER

MANUFACTURER AND COORDINATED WITH THE FIELD CONTRACTING OFFICER

REPRESENTATIVE (COR).

4. PROVIDE CONDENSATE ACID NEUTRALIZATION KIT FROM THE SAME MANUFACTUER.

GENERAL NOTES:

1/4" = 1'-0"A1 Mechanical Room Section

EXISTING BOILER

BREECHING

INTAKE OA PLENUM

Sheets
M-111 - MECHANICAL ROOM PLAN

File details come from the government source that posted it. Updated .