A-605 and S-102 S-103 Amd 5.pdf

PDF 236 KB Posted

Attached to
Renovate Bldg. 125 Fort Hamilton, Brooklyn, New York
Solicitation number
W912DS23B0022
Issued by

About this file

This package includes construction drawings and specifications for the renovation of Building 125 at Fort Hamilton in Brooklyn, New York. The scope of work involves installing a prefabricated ramp at the building entrance, upgrading interior finishes, and modifying existing restrooms to meet accessibility requirements. The solicitation was issued by the U.S. Army Corps of Engineers New York District on behalf of the 1st Marine Corps District for Solicitation W912DS23B0022 to renovate the building for occupancy by Marine Corps personnel. The specifications identify required wall, flooring, ceiling, and restroom materials. The drawings provide layouts, dimensions, and structural details for the prefabricated ramp.

View the file

Other files

File Type Posted
C.04.01 Bid Abstract Bldg 125 Final.pdf PDF
B.08.03 Amendment 05.pdf PDF
09 06 00 Amd 5.pdf PDF
10 21 13 Amd 5.pdf PDF
E-002 and ED102 Amd 3.pdf PDF
LEED_v4_for_Interior_Design_and_Construction_Checklist B125 Reno Ft Hamilton.pdf PDF
Army_SustainabilityReportCard_2020 B125 Renovation LEED IDC.pdf PDF
Fort Hamilton Planning Charrete.pdf PDF
M-101 thru 107 (rev 02) and 602 (rev 01) Amd 5.pdf PDF
07 27 10 Amd 5.pdf PDF
12 50 00.13 FFE Data Sheet Item Code M4 revised.pdf PDF
01 33 29 Amd 5.pdf PDF
B.08.03 Amendment 04.pdf PDF
B.08.03 Amendment 03.pdf PDF
A-405 20230830.pdf PDF
A-408 20230830.pdf PDF
A-501 20230831.pdf PDF
1AB-101 20230830.pdf PDF
A-605 20230831.pdf PDF
A-101 A-403 A-501 AD-101 AD-403 20230829.pdf PDF
Renovation BLDG 125-Mechanical Room - Sheet - M-111 - MECHANICAL ROOM PLAN.pdf PDF
B.08.03 Amendment 02.pdf PDF
A-602 Amendment 2 20230823.pdf PDF
Amendment 2 Mechanical Drawings M102 thru 107 M601 M701.pdf PDF
A-404 Amendment 2 20230824.pdf PDF
A-601 Amendment 2 20230823.pdf PDF
B.08.03 Amendment 01.pdf PDF
B.08.03 Site Visit Sign in sheet_16 Aug 23 (002).jpg JPG image
B.08.03 Invitation for Bid W912DS23B0022.pdf PDF
JA_Hamilton_125_Simplex Signed.pdf PDF
Fort Hamilton Bldg 125-100_PCNT_Specification_07-31-2023.pdf PDF
B.08.03 Invitation for Bid W912DS23B0022.pdf PDF
B125 RTA Complete set R4 07 August 2023.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

U s e rs

\e e n d c m g \D o c u m e n ts

\F o rt

H a m ilt o n B u ild in g

\M o d e l\ B

-D

M M

-A -M

D L .r v t

/6

/2

:4

:1

P

M

A-605

F

IN

IS

H

S C

H E

D U

L E

W

A

IN

W R

IG

H

T D

R B

R O

O K

L Y

N N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

C .G

C .G

C .G

C .G

A U

G U

S T

W D

S -2

-B

-0

B L D

G

S T

M A

R

IN

E C

O R

P S

D

IS

T R

IC

T

R E

L O

C A

T

IO

N T

O F

T

H A

M

IL

T O

N N

Y

N o te s D e le te d

F ro m D ra w in g

/3

/2

F in is h s c h e d u le u p d a te d t o s h o w

P F

T i n

R o o m

/0

/2

FINISH SCHEDULE

ROOM

NO ROOM NAME

WALL FINISH BASE FINISH FLOOR

NOTES & REMARKS (SEE NOTES)NORTH EAST SOUTH WEST

NORT

H EAST

SOUT

H WEST MAT.

FLOOR PLAN

001 VESTIBULE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 IMBEDDED

MAT

PROVIDE WALK OFF MAT FOR FLOOR

100A CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

101 SORTING ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

102 STUDIO/ PRINT ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

103 BREAK ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 PFT

104 RECRUITER INSTRUCTOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

105 LACTATION ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

106 TRAINING TEAM DEPUTY PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

107 MENS RESTROOM PWT, PT-1 PWT,PT-1 PWT-PT-1 PWT,PT-1 N/A N/A N/A N/A PFT PWT FROM FINISH FLOOR TO 5', PAINT UP TO CEILING

107A MENSLOCKER AND SHOWER PWT, PT-1 PWT,PT-1 PWT-PT-1 PWT,PT-1 N/A N/A N/A N/A PFT PWT FROM FINISH FLOOR TO 5', PAINT UP TO CEILING

108 TRAINING TEAM OIC PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

109 WOMENS REST ROOM PWT, PT-1 ETR,PT-1 PWT-PT-1 PWT,PT-1 N/A N/A N/A N/A PFT PWT FROM FINISH FLOOR TO 5', PAINT UP TO CEILING

109A WOMENS LOCKER AND SHOWER PWT, PT-1 PWT,PT-1 PWT-PT-1 PWT,PT-1 N/A N/A N/A N/A PFT PWT FROM FINISH FLOOR TO 5', PAINT UP TO CEILING

110 CLASSROOM/ CONFERENCE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

111 OPERATIONS OFFICER PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

114 WORK SPACE AREA PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

115 TRAINING TEAM CHIEF PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

116 ELECTRIC PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED

CONC.

117 PRIOR SERVICE RECRUITING OIC

(PSR)

PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

118 TELECOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED

CONC.

119 MARKETING AND COMM O PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

120 CONFERENCE ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

121 SGT MAJOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

122 CHAPLAIN PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

123 COMMANDING OFFICER PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

124 CAREER PLANNER PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

125 EX OFFICER PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

126 TECH EQUIPMENT AREA PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

126A I/T PROGRAM MGMT SPVR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

126B TELECOM/ INTERNET SERVER

ROOM

PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED

CONC.

127 ADJUDANT PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

127A FP ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED

CONC.

128 ELECTRIC PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED

CONC.

128A MECHANICAL ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED

CONC.

129 DEPLOYMENT READYNESS

COORDINATOR

PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

130 J.C. PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED

CONC.

131 MISSION ASSURANCE PM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

131A UTILITY CHASE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED

CONC.

132 WORK SPACE AREA 2 PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

133 FEMALE RESTROOM/ LOCKERS PWT, PT-1 PWT,PT-1 PWT-PT-1 PWT,PT-1 N/A N/A N/A N/A PFT PWT FROM FINISH FLOOR TO 5', PAINT UP TO CEILING

134 PERSONNEL OFFICER PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

135 MALE RESTROOM/SHOWERS PWT, PT-1 PWT,PT-1 PWT-PT-1 PWT,PT-1 N/A N/A N/A N/A PFT PWT FROM FINISH FLOOR TO 5', PAINT UP TO CEILING

136 ADMIN SUPPORT COORDINATOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

137 SACO SUBSTANCE ABUSE ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

138 ALL HANDS CONFERENCE ROOM/

CLASS ROOM

PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

139 SUPPLY/LOG MGT SPEC (MEDICAL) PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

140 COMPTROLLER PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

141 SUPPLY OFFICER PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

142 DEP COMPTROLLER PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

143 SUPPLY CHIEF PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

144 SARC PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

145 SUPPLY MGMT SPECIALIST PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

146 WORK SPACE AREA 3 PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

147 LOGISTICS MGMT SPECIALIST PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

148 WAREHOUSE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED

CONC.

148A WAREHOUSE VESTIBULE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED

CONC.

149 LOGISTICS OFFICER PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 CPT-1

GENERAL NOTES:

1. SEE A-604 FOR CEILING MOUNTING HEIGHTS.

2. SEE A-102 FOR CEILING FINISH

PREFABRICATED RAMP FOOTING PLAN

*FIELD VERIFY ALL DIMENSIONS

*VERIFY/COORDINATE FOOTER LOCATIONS WITH

MANUFACTURER

4000 PSI CONCRETE W/ #4

@ 12" E.W. W/ 12" HAUNCH

AROUND PERIMETER.

MATCH EXISTING

GRADE TO PROVIDE

SMOOTH TRANSITION

KTR SHALL NOT DISTURB

EXISTING BUILDING/STAIR

FOUNDATION AND WALL

DURING CONSTRUCTION

PREFABRICATED RAMP FOOTING

*FIELD VERIFY ALL DIMENSIONS

6" AASHTO

#57 STONE

#4 @12 E.W.

EACH FACE

#4 @ 12" E.W.

4000 PSI

CONCRETE

10 MIL VAPOR

BARRIER

PREFABRICATED RAMP/SLAB JUNCTION DETAIL

*FIELD VERIFY ALL DIMENSIONS

6" AASHTO #57

STONE

#4 @12 E.W.

EACH FACE

#4 @ 12" E.W.

4000 PSI CONCRETE

10 MIL

VAPOR

BARRIER

4000 PSI CONCRETE W/ #4

@12" E.W. MATCH PREFAB

RAMP FINISH.

HAUNCH SLAB

PERIMETER TO

MIN. OF 12"

1_

PREFORMED EXPANSION

MATERIAL. COORDINATE FINISHED

ELEVATION WITH PREFABRICATED

RAMP TO ENSURE SMOOTH

TRANSITION

NOTCH FOR SLAB

BEARING

EXTENTS OF PROPOSED

PREFABRICATED RAMP.

KTR SHALL COORDINATE

FOOTING LOCATIONS

WITH MANUFACTURER

4" R

A M

P 6'

-0

LA

N

D

IN

G 5'

-6

LA

N

D

IN

G 11 1/2"

6"OFFSET FROM F.O. BLG

8' -9

/2

"V .I.

F.

EX

IS

TI

N G

L A

N D

IN

G

6' -0

4'-0"

5' -1

1" 5'

-1 1"

6' -0

6'

-0

13'-0"

6'-1 1/4"

3"6" 3"

1' -0

3"

3" 1'

-0

6"

1' -0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

U s e rs

\e e n d c m g \D o c u m e n ts

\F o rt

H a m ilt o n B u ild in g

\M o d e l\ B

-D

M M

-A -M

D L .r v t

/6

/2

:3

:0

A

M

S-102

A B

A R

A M

P D

E T

A

IL

S

W

A

IN

W R

IG

H

T D

R B

R O

O K

L Y

N N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

D e s ig n e r

A u th o r

C h e c k e r

A U

G U

S T

W D

S -2

-B

-0

B L D

G

S T

M A

R

IN

E C

O R

P S

D

IS

T R

IC

T

R E

L O

C A

T

IO

N T

O F

T

H A

M

IL

T O

N N

Y

S h e e t A d d e d t o

S tr u c tu ra l S e t

/0

/2

3/8" = 1'-0"

ABA STRUCTURAL DETAILS RAMP 01

F

PREFABRICATED RAMP FOOTING

*FIELD VERIFY ALL DIMENSIONS

6" AASHTO

#57 STONE

#4 @12 E.W.

EACH FACE

#4 @ 12" E.W.

4000 PSI CONCRETE

10 MIL VAPOR

BARRIER

PREFABRICATED RAMP FOOTING PLAN

*FIELD VERIFY ALL DIMENSIONS

*VERIFY/COORDINATE FOOTER LOCATIONS WITH MANUFACTURER

PREFABRICATED RAMP/SLAB JUNCTION DETAIL

*FIELD VERIFY ALL DIMENSIONS

6" AASHTO #57

STONE

#4 @12 E.W. EACH FACE

#4 @ 12" E.W.

PSI

CONCRETE

10 MIL VAPOR

BARRIER

4000 PSI CONCRETE

W/ #4 @ 12" E.W.

WITH 12" HAUNCH

AROUND

PERIMETER

4000 PSI CONCRETE W/

#4 @12" E.W. MATCH

PREFAB RAMP FINISH.

HAUNCH SLAB

PERIMETER TO

MIN. OF 12"

1_

PREFORMED EXPANSION

MATERIAL. COORDINATE

FINISHED ELEVATION WITH

PREFABRICATED RAMP TO

ENSURE SMOOTH TRANSITION

EXISTING BUILDING

4000 PSI CONCRETE W/

#4 @ 12" E.W. W/ 12"

HAUNCH AROUND

PERIMETER.

MATCH EXISTING GRADE

TO PROVIDE SMOOTH

TRANSITION

B

3"6"

3"

"1

6'-0"8'-11"8'-11"4'-0"

0"

6"

2'-0"

9'-0"

0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

U s e rs

\e e n d c m g \D o c u m e n ts

\F o rt

H a m ilt o n B u ild in g

\M o d e l\ B

-D

M M

-A -M

D L .r v t

/6

/2

:3

:0

A

M

S-103

A B

A R

A M

P D

E T

A

IL

S

W

A

IN

W R

IG

H

T D

R B

R O

O K

L Y

N N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

D e s ig n e r

A u th o r

C h e c k e r

A U

G U

S T

W D

S -2

-B

-0

B L D

G

S T

M A

R

IN

E C

O R

P S

D

IS

T R

IC

T

R E

L O

C A

T

IO

N T

O F

T

H A

M

IL

T O

N N

Y

N o te s D e le te d

F ro m D ra w in g

/3

/2

1/4" = 1'-0"

ABA STRUCTURAL DETAILS RAMP 02

A-605 Amd 5
Sheets
A-605 - FINISH SCHEDULE
S-102 S-103 Amd 5
Sheets
S-102 - ABA RAMP DETAILS
S-103 - ABA RAMP DETAILS

File details come from the government source that posted it. Updated .