A-101 A-403 A-501 AD-101 AD-403 20230829.pdf
PDF 2 MB Posted
- Solicitation number
- W912DS23B0022
About this file
This set of construction documents includes plans and specifications for renovating Building 125 at Fort Hamilton in Brooklyn, New York. The project involves demolishing existing interior partitions and systems and constructing new tenant spaces, including offices, conference rooms, and storage areas. Key aspects of the work include installing new mechanical, electrical and plumbing systems; erecting fire-rated walls; and upgrading the life safety, fire alarm and suppression systems. The solicitation is for a firm fixed-price construction contract awarded by the U.S. Army Corps of Engineers, New York District. The renovation aims to relocate the 1st Marine Corps District headquarters to better suit its needs.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
DN
DN
DN
DN
DN
R E
F
REF.
FACP
TRA
F
FFFFF
F
BAT
DS
DS
LOC
LOC
LOC
F
F
F
DN
DN
FDFDFD
FDFD
FD
A-201
A-201
A-201
A-402
A-401
A-403
A-301
A-302
A-302
A-302
A-302
A-301
B
A
1 2 3 4 5 6 87
107A
116 118
106108
122124
126B
125127
128A
135 133
134136
145147149
126A
109A
100A
40' - 10 1/2"
/2
12' - 0"
A-408
131A 127A
148A
425' - 0"
336' - 5 1/4"
0 8' 16' 32'
SCALE: 1/16" = 1'-0"
N
LEGEND
MASONRY PARTITION
(SEE PARTITION SCHEDULE
FOR MORE INFORMATION)
NO FIRE RATING
1 HR FIRE RATING
GENERAL NOTES
1. SEE A-401 - A-403 FOR WALL TAGS, DOOR TAGS, WINDOW
TAGS,
2. SEE DRAWING A-103 FOR ROOM SCHEDULE
3. CONTRACTOR WILL INSPECT INSULATION AND
VAPOR BARRIER IN EAST SIDE OF THE BUILDING.
IF THE INSULATION AND VAPOR RETARDER ARE
NOT COMPLIANT WITH ASHRAE 90.1 AND HAVE AN
R VALUE OF R-49 CONTRACTOR WILL INSTALL
NEW INSULATION MEETING THE REQUIREMENTS
AND VAPOR RETARDER AS PER WALL SECTION 4
IN SHEET A-304
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
C
U s e rs
\e e n d c m g \D o c u m e n ts
\F o rt
H a m ilt o n B u ild in g
\M o d e l\ B
-D
M M
-A -M
D L .r v t
/2
/2
:4
:1
P
M
A-101
F L O
O R
P L A
N
W
A
IN
W R
IG
H
T D
R B
R O
O K
L Y
N N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
C .G
C .G
C .G
C .G
A U
G U
S T
W D
S -2
-B
-0
B L D
G
S T
M A
R
IN
E C
O R
P S
D
IS
T R
IC
T
R E
L O
C A
T
IO
N T
O F
T
H A
M
IL
T O
N N
Y
1/16" = 1'-0"
PROPOSED FLOOR PLAN
R e v is io n s t o w a ll ty p e s
/2
/2
F
LOC
F
DN
2107 SF
WAREHOUSE
682 SF
ALL HANDS
CONFERENCE
ROOM/ CLASS
ROOM
105 SF
SUPPLY OFFICER
100 SF
SUPPLY CHIEF
100 SF
SUPPLY MGMT
SPECIALIST
145100 SF
LOGISTICS MGMT
SPECIALIST
114 SF
LOGISTICS
OFFICER
100 SF
DEP
COMPTROLLER
2305 SF
WORK SPACE
AREA 3
114 SF
SUPPLY/LOG MGT
SPEC (MEDICAL)
100 SF
COMPTROLLER
65 SF
SACO
SUBSTANCE
ABUSE ROOM
113 SF
SARC
7' - 4"
A-301
A-301
B
A
3 4 5
A01
A01
A01 A01 A01
A01
A01
A01 A01
A01
A01
A01
A01
A01
A01
A01
132A
132B
137139141143145147149
137B
142 140
137A
10' - 0"
/2
6' - 5 1/2"11' - 4"10' - 0"
W1W1W1W1W1W1
W1W1W1
147C
A-408
Sim
147E
147D
A02A02
37' - 5 1/2"
8'4' 16'0
SCALE: 3/16" = 1'-0"
8'4' 16'0
SCALE: 3/16" = 1'-0"
N
XXX
XX
XX
XX
FD
LEGEND
DOOR TAG
WINDOW TAG
WALL TAG
EQUIPMENT
FLOOR DRAIN
XX LOUVER TAG
MASONRY PARTITION
(SEE PARTITION SCHEDULE
FOR MORE INFORMATION)
NO FIRE RATING
1 HR FIRE RATING
KEY PLAN
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
C
U s e rs
\e e n d c m g \D o c u m e n ts
\F o rt
H a m ilt o n B u ild in g
\M o d e l\ B
-D
M M
-A -M
D L .r v t
/2
/2
:4
:1
P
M
A-403
E N
L A
R G
E D
F L O
O R
P L A
N
W
A
IN
W R
IG
H
T D
R B
R O
O K
L Y
N N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
C .G
C .G
C .G
C .G
A U
G U
S T
W D
S -2
-B
-0
B L D
G
S T
M A
R
IN
E C
O R
P S
D
IS
T R
IC
T
R E
L O
C A
T
IO
N T
O F
T
H A
M
IL
T O
N N
Y
3/16" = 1'-0"
ENLARGED FLOOR PLAN 3
R e v is io n s t o w a ll ty p e s
/2
/2
LIGHT GAUGE STUD & GYP. BD.
COMPOSITE ASSEMBLY A
CHASE WALL
NON-COMP. BRACED AT 48 IN. O.C.C
A01
3 5/8" METAL STUD
5/8" GYPSUM BD. - BOTH SIDES
ACTUAL THICKNESS - 4 7/8"
UL: NONE
FIRE RATING: NONE
STC RATING: 52
CF1
(2) 3 5/8" METAL STUD
5/8" GYPSUM BD. - BOTH SIDES
8" AIR SPACE
ACTUAL THICKNESS - 1'-4 1/2" MIN.
UL: NONE
FIRE RATING: NONE
STC RATING: 52
TO STRUCTURE ABOVE
METAL STUD
METAL RUNNER CHANNEL
GYP. BOARD
CEILING
METAL RUNNER CHANNEL
ROOF DECK
GYP. BOARD
METAL STUD
CEILING
METAL RUNNER
CHANNEL
ROOF DECK
METAL RUNNER CHANNEL
A02
3 5/8" METAL STUD
5/8" GYPSUM BD. - BOTH SIDES
ACTUAL THICKNESS - 4 7/8"
UL: DES NO. U419
FIRE RATING: 1 HR
STC RATING: 52 (RAL-TL11-125)
CHASE WALL ON EXTERIOR WALL
CEILING
ROOF DECK
8" AIR SPACE
GYP. BOARD
METAL STUD
F
F01
3 5/8" METAL FURRING (ONE SIDE)
5/8" GYPSUM BD. (ONE SIDE)
8" AIR SPACE
ACTUAL THICKNESS - 1' 1/4"
UL: NONE
FIRE RATING: NONE
STC RATING: 52 (RAL-TL11-125)
METAL RUNNER CHANNEL
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
C
U s e rs
\e e n d c m g \D o c u m e n ts
\F o rt
H a m ilt o n B u ild in g
\M o d e l\ B
-D
M M
-A -M
D L .r v t
/2
/2
:4
:1
P
M
A-501
P A
R T
IT
IO
N T
Y P
E S
W
A
IN
W R
IG
H
T D
R B
R O
O K
L Y
N N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
C .G
C .G
C .G
C .G
A U
G U
S T
W D
S -2
-B
-0
B L D
G
S T
M A
R
IN
E C
O R
P S
D
IS
T R
IC
T
R E
L O
C A
T
IO
N T
O F
T
H A
M
IL
T O
N N
Y
DNDN DN
DN
DN
WH
DN
FACP
TRA F
F F
F
M T
S
54' - 6 1/2"
/2
22' - 9"
/2
21' - 6"
AD-401
AD-402
AD-403
AD-301
AD-302
AD-302 3
AD-302
AD-302
AD-301
BASKETBALL COURT
WALK-IN BOX
MECHANICAL ROOM
THRIFT SHOPDTMS POST CAGESDPW FAMILY HOUSING
B
A
1 2 3 4 5 6 87
24' - 0" 13' - 0" 24' - 0"
21' - 6"
A-105
EXISTING WALL TO REMAIN.
PATCH AND REPAIR AS
REQUIRED
EXISTING WALL TO BE
DEMOLISHED
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE
DEMOLISHED
LEGEND1. THESE NOTES ARE GENERAL AND NOT INTENDED TO BE WHOLLY
INCLUSIVE. REMOVE ALL EXISTING CONDITIONS TO THE NOTED EXTENT.
2. REFER TO ORIGINAL AS-BUILTS BEFORE DEMOLITION OF CMU PARTITIONS
AND MEP EQUIPMENTS.
3. DASHED LINES DENOTE EXISTING TO BE REMOVED.
4. THIS PLAN IS REFERENCE ONLY. THE GOVERNMENT DOES NOT
GUARANTEE ACCURACY OF THE EXISTING CONDITION.
5. FOR REMOVAL OF PLUMBING ITEMS SEE PLUMBING DRAWINGS.
6.FOR REMOVAL OF MECHANICAL ITEMS SEE MECHANICAL DRAWINGS.
7. FOR REMOVAL OF ELECTRICAL ITEMS SEE ELECTRICAL DRAWINGS.
8. FOR REMOVAL OF FIRE PROTECTION ITEMS SEE FIRE PROTECTION
DRAWINGS.
9. ALL WALL FINISH ON EXTERIOR WALL TO BE REMOVED TO STRUCTURE
10. FOR ALL SANITARY TRENCHING, SEE PLUMBING AND MECHANICAL
DRAWINGS
11. DEMOLISH ALL EXISTING CEILINGS
GENERAL NOTES
0 8' 16' 32'
SCALE: 1/16" = 1'-0"
N
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
C
U s e rs
\e e n d c m g \D o c u m e n ts
\F o rt
H a m ilt o n B u ild in g
\M o d e l\ B
-D
M M
-A -M
D L .r v t
/2
/2
:4
:1
P
M
AD-101
D E
M O
L
IT
IO
N
P L A
N
W
A
IN
W R
IG
H
T D
R B
R O
O K
L Y
N N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
C .G
C .G
C .G
C .G
A U
G U
S T
W D
S -2
-B
-0
B L D
G
S T
M A
R
IN
E C
O R
P S
D
IS
T R
IC
T
R E
L O
C A
T
IO
N T
O F
T
H A
M
IL
T O
N N
Y
1/16" = 1'-0"
DEMOLITION FLOOR PLAN
A d ju s tm e n t in
W in d o w s a n d
D o o r
S c h e d u le
/d e le ti o n a n d a d d it o n o f n o te s i n d ra w in g s
/2
/2
R e v is io n s t o w a ll ty p e s
/2
/2
AD-301
AD-302
AD-301
DTMS POST CAGESDPW FAMILY HOUSING
B
A
3 4 5
111111
11 11 11 11 11 11 112
2 2
INFILL OPENING IN KIND
INFILL OPENING IN KIND
EXISTING WALL TO REMAIN.
PATCH AND REPAIR AS
REQUIRED
EXISTING WALL TO BE
DEMOLISHED
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE
DEMOLISHED
LEGEND
1. THESE NOTES ARE GENERAL AND NOT INTENDED TO BE WHOLLY
INCLUSIVE. REMOVE ALL EXISTING CONDITIONS TO THE NOTED EXTENT.
2. REFER TO ORIGINAL AS-BUILTS BEFORE DEMOLITION OF CMU PARTITIONS
AND MEP EQUIPMENTS.
3. DASHED LINES DENOTE EXISTING TO BE REMOVED.
4. THIS PLAN IS REFERENCE ONLY. THE GOVERNMENT DOES NOT
GUARANTEE ACCURACY OF THE EXISTING CONDITION.
5. FOR REMOVAL OF PLUMBING ITEMS SEE PLUMBING DRAWINGS.
6.FOR REMOVAL OF MECHANICAL ITEMS SEE MECHANICAL DRAWINGS.
7. FOR REMOVAL OF ELECTRICAL ITEMS SEE ELECTRICAL DRAWINGS.
8. FOR REMOVAL OF FIRE PROTECTION ITEMS SEE FIRE PROTECTION
DRAWINGS.
9. ALL WALL FINISH ON EXTERIOR WALL TO BE REMOVED TO STRUCTURE
10. FOR ALL SANITARY TRENCHING, SEE PLUMBING AND MECHANICAL
DRAWINGS
11. DEMOLISH ALL EXISTING CEILINGS
GENERAL NOTES
DEMOLITION NOTES
CASEWORK TO BE REMOVED
2 DOOR AND FRAME TO BE REMOVED
WALL TO BE REMOVED
4 PLUMBING FIXTURE TO BE REMOVED
FLOOR FINISH TO BE REMOVED5
CONCRETE SLAB TO BE REMOVED6
STAIR TO BE REMOVED7
PARTIAL WALL TO BE REMOVED FOR DOOR8
REMOVE SLAB ABOVE FINISH FLOOR9
FILL IN DEPRESSED SUMP PUMP SLAB10
REMOVE WINDOW, FRAME, CONCRETE SILL AND FLASHING11
OVERHEAD DOOR TO BE REMOVED AND INFILLED WITH CMU
BLOCK
CONC. RAMP AND METAL RAILING TO BE REMOVED13
WINDOW AND FRAME TO BE REMOVED PREP OPENING FOR
INFILL WITH CMU BLOCK
PREP AREAS FOR PLUMBING FIXTURES15
N
8'4' 16'0
SCALE: 3/16" = 1'-0"
8'4' 16'0
SCALE: 3/16" = 1'-0"
KEY PLAN
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
C
U s e rs
\e e n d c m g \D o c u m e n ts
\F o rt
H a m ilt o n B u ild in g
\M o d e l\ B
-D
M M
-A -M
D L .r v t
/2
/2
:4
:1
P
M
AD-403
E N
L A
R G
E D
D E
M O
L
IT
IO
N
P L A
N
W
A
IN
W R
IG
H
T D
R B
R O
O K
L Y
N N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
C .G
C .G
C .G
C .G
A U
G U
S T
W D
S -2
-B
-0
B L D
G
S T
M A
R
IN
E C
O R
P S
D
IS
T R
IC
T
R E
L O
C A
T
IO
N T
O F
T
H A
M
IL
T O
N N
Y
3/16" = 1'-0"
ENLARGED DEMOLITION PLAN 3
R e v is io n s t o w a ll ty p e s
/2
/2
BUILDING LOCATION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
C
U s e rs
\e e n d c m g \D o c u m e n ts
\F o rt
H a m ilt o n B u ild in g
\M o d e l\ B
-D
M M
-A -M
D L .r v t
/2
/2
:4
:1
P
M
G-001
C O
V E
R S
H E
E T
W
A
IN
W R
IG
H
T D
R B
R O
O K
L Y
N N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
C .G
C .G
C .G
C .G
A U
G U
S T
W D
S -2
-B
-0
B L D
G
S T
M A
R
IN
E C
O R
P S
D
IS
T R
IC
T
R E
L O
C A
T
IO
N T
O F
T
H A
M
IL
T O
N N
Y
NEW YORK DISTRICT
W912DS-23-B-0022
AUGUST 1, 2023
125 WAINWRIGHT DR., BROOKLYN NY 11209
BLDG 125 1ST MARINE CORPS DISTRICT
RELOCATION TO FT. HAMILTON, NY
103259
R.T.A.
DRAWING ABBREVIATIONS INDEX OF DRAWINGS BUILDING SUMMARY
NUMBERING SYSTEM:
XX100
DISCIPLINE:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
K - FOOD SERVICE
DISCIPLINE MODIFIER
SHEET NUMBER WITHIN
SERIES
ANNOTATION CALLOUTS/DRAWING SYMBOLS
GENERAL NOTES
A ---------------------
A LABELCLASS A DOOR
A/C AIR CONDITION
A/C UNITAIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNLACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABELCLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
C LABELCLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABELCLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
G ---------------
GB GRAB BAR
GFCI GOVERNMENT FURNISHED CONTRACTOR
INSTALLED
GFGI GOVERNMENT INSTALLED FURNISHED
INSTALLED BY GOVERNMENT
GFRG GLASS-FIBER-REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H -------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED CONTRACTOR
INSTALLED
GFGI GOVERNMENT INSTALLED FURNISHED
INSTALLED BY GOVERNMENT
GFRG GLASS-FIBER-REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
REFER TO AEC CAD
STANDARDS FOR PROPER
SHEET NUMBERING
LEGEND
CONCRETE/ PRECAST
CONCRETE
SOIL
SAND, EIFS FINISH COAT,
OR CEMENT PLASTER
BRICK
CMU
STONE
FIBERGLASS SEMI RIGID
INSULATION
FIBERGLASS BATT
INSULATION
MINERAL WOOL SEMI
RIGID INSULATION
EXPANDED
POLYSTYRENE RIGID
INSULATION
EXTRUDED
POLYSTYRENE RIGID
INSULATION
POLYISOCYANURATE
RIGID INSULATION
GYPSUM BOARD
EXTERIOR GYPSUM
SHEATHING
EXTERIOR CEMENT
BOARD
COATED GLASS MAT
WATER RESISTANT
GYP BD
PLYWOOD
COVER BOARD
MATERIALS
S
1 HR FIRE
S
S
S
1 HR FIRE/SMOKE WALL
4 HR FIRE
4 HR FIRE/SMOKE WALL
2 HR FIRE
2 HR FIRE/SMOKE WALL
3 HR FIRE
3 HR FIRE/SMOKE WALL
FIRE RATED WALL SYMBOLS:
*UNLESS OTHERWISE NOTED ON THE DRAWINGS
CEILING SYMBOLS
1i
GRID / COLUMN
LINE
DESIGNATOR
EQUIPMENT NUMBER
DOOR NUMBER
X
WALL TYPE
WINDOW TYPE
Room name
101 ROOM NAME/NUMBER
REVISION TAG
PLAN NORTH
NORTH ARROW w/
TRUE NORTH
INDICATION
EGRESS ROUTE ID
AND SECTION
LENGTH
Room
Rm_Occupancy
150 SF
EGRESS :Egress_ID
Egress_Length
ROOM OCCUPANCY
& AREA
ELEVATION NUMBER
SECTION
EXTERIOR ELEVATION
ENLARGEMENT,
DETAIL
SPOT ELEVATION
Name
Elevation
FLOOR LEVEL & NAME
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A SHEET KEYNOTE
A101
Ref
R e f
Ref
R e f
INTERIOR ELEVATION
A-101
1 TYP
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
EXIT LIGHT
2' x 2' ACT CEILING
4' x 4' ACT CEILING
GYP. BD. CEILING
1' x 1' ACT CEILING
2 X 4 LIGHT FIXTURE
2 x 2 LIGHT FIXTURE
SUSP. FLUORESCENT
LIGHT
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
PROJECT INFORMATION
PROJECT NAME: BLDG 125 1ST MARINE CORPS DISTRICT RELOCATION TO FT. HAMILTON, NY
PROPOSED USE: BUSINESS/ STORAGE
OWNER-CONTACT PERSON: CONTRACTING OFFICER
APPLICABLE CODES
REFER TO SHEET FS100 AND FS101 FOR APPLICABLE CODES
BUILDING PLANNING
THIS IS A MIXED OCCUPANCY BUILDING
FIRE SEPARATION IS REQUIRED, REFER TO SHEET FS101, MIXED USE AND OCCUPANCY
SEPARATION
REFER TO SHEET G-004 FOR BUILDING AREA TABULATILONS AND CATEGORY CODES GROSS
SQUARE FOOTAGE
TYPE OF CONSTRUCTION
CONSTRUCTION TYPE: THE BUILDING WILL BE TYPE II B FULLY SPRINKLERED CONSTRUCTION
PER IBC. STEEL STUD BACK-UP AND CONCRETE MASONRY UNIT (CMU) BACK-UP CAVITY WALLS
WITH RIGID INSULATION AND BRICK VENEER ON EXTERIOR SIDE. FLOOR IS CONCRETE SLAB-ON-
GRADE WITH AN UNDERGROUND CABLE VAULT. REFER TO SHEET FS100.
ESSENTIAL FACILITY (CHAPTER 16, IBC)
NOT AN ESSENTIAL FACILITY
GENERAL BUILDING LIMITATIONS
REFER TO SHEET FS100 FOR BUILDING AREA AND HEIGHT LIMITATION CALCULATIONS
FIRE PROTECTION SYSTEMS
REFER TO (FA) SHEET FOR FIRE ALARM SYSTEM, INCLUDING SMOKE CONTROL AND (FX) SHEETS FOR
FIRE SUPPRESSION SYSTEM TO INCLUDE STANDPIPE.
FIRE RESISTANT CONSTRUCTION
REFER TO SHEET FS101 FIRE RESISTIVE REQUIREMENTS
OPTIONAL ITEMS
ALL DRAWINGS WITH 1 IN FRONT OF DISCIPLINE DESIGNATOR EXAMPLE 1A-201 WILL HAVE
ELEMENTS THAT RE LISTED IN THE OPTIONAL BID ITEMS
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
C
U s e rs
\e e n d c m g \D o c u m e n ts
\F o rt
H a m ilt o n B u ild in g
\M o d e l\ B
-D
M M
-A -M
D L .r v t
/2
/2
:4
:1
P
M
G-002
G E
N E
R A
L N
O T
E S
W
A
IN
W R
IG
H
T D
R B
R O
O K
L Y
N N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
C .G
C .G
C .G
C .G
A U
G U
S T
W D
S -2
-B
-0
B L D
G
S T
M A
R
IN
E C
O R
P S
D
IS
T R
IC
T
R E
L O
C A
T
IO
N T
O F
T
H A
M
IL
T O
N N
Y
1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF THE WORK. THE DRAWINGS ARE NOT
INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE
AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, ON THE BASIS
OF THE GENERAL PERFORMANCE CRITERIA AND GENERAL EXTENT OF WORK INDICATED,
DESCRIBED OR REQUIRED.
2. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT
DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR
IMPLIED.
3. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK
SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.
4. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S PUBLISHED
STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP. ANY CONFLICTING
REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE
CONTRACTING OFFICER'S ATTENTION PRIOR TO PROCEEDING WITH THE WORK.
5. THE CONTRACTOR SHALL PROTECT EXISTING, IN-PLACE, AND NEW WORK.
6. ALL WORK NOTED "N.I.C." OR "G.F.G.I." IS MEANT TO EXCLUDE THIS SCOPE OF WORK FROM
THE CONSTRUCTION CONTRACT.
7. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE COLLECTION, SEPARATION,
RECYCLE, REMOVAL AND LEGAL DISPOSAL OF MATERIALS AND RUBBISH.
8. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL VERIFY ALL NEW AND
EXISTING CONDITIONS, SHOWN. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING
OFFICER IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
COMMENCEMENT OF WORK SHALL CONSTITUTE ACCEPTANCE OF ALL NEW AND EXISTING
CONDITIONS.
9. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER
SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER IN
WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
10. ALL DIMENSIONS INDICATED ARE NOT TO VARY BY MORE THAN 1/8".
11. NFPA 241, STANDARD IS CALLED STANDARD FOR SAFEGUARDING CONSTRUCTION,
ALTERATION, AND DEMOLITION OPERATIONS SHALL BE APPLIED.
12. WALL AND CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH A FIRE RESISTIVE RATING
SHALL BE CONSTRUCTED AS DETAILED OR REFERENCED BY UL OR OTHER REFERENCE.
13. DIMENSIONS SHOWN TO STRUCTURAL BEAMS AND COLUMNS ARE TO THE CENTERLINE OF
THE MEMBER UNLESS SPECIFICALLY NOTED OTHERWISE.
14. PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS PER PRODUCT
MANUFACTURER'S STANDARDS.
15. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE
CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY
BUILDING AND FIRE PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION.
16. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC
CORROSION.
17. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. SHEETS
ARE TO BE REVIEWED AND NOTES ON ANY ONE SHEET ARE TO BE APPLIED TO RELATED
DRAWINGS AND DETAILS.
18. ALL FINISH AND FIRE RATING REQUIREMENTS INDICATED SHALL APPLY TO THE ENTIRE
LENGTH AND HEIGHT OF THE WALL.
19. WHEN NON-DIMENSIONED PARTITIONS APPEAR IN CONJUNCTION WITH DOOR OPENINGS,
THE DOOR WIDTH AND THE DOOR FRAME DETAILS DETERMINE THE LOCATION OF
ADJACENT WALLS AND FRAMES.
20. DETAILS INDICATED FOR CONSTRUCTION ARE TO BE USED FOR ALL LOCATIONS OF
SIMILAR CONSTRUCTION. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT
CANNOT BE DETERMINED, CONSULT THE CONTRACTING OFFICER BEFORE PROCEEDING
WITH THE WORK.
21. THE CONTRACTOR SHALL COORDINATE ALL PENETRATIONS WITH ALL TRADES.
22. PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS REQUIRED FOR
MECHANICAL EQUIPMENT AND PLUMBING WORK. ALL ACCESS PANEL LOCATIONS SHALL BE
REVIEWED WITH THE CONTRACTING OFFICER PRIOR TO PROCEEDING.
23. ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE ASSEMBLIES SHALL BE INSTALLED IN A
MANNER THAT WILL PRESERVE THE MOISTURE RESISTANCE, FIRE RATING, AND
STRUCTURAL INTEGRITY OF THE ASSEMBLY.
24. CONTRACTOR SHALL PLAN THEIR WORK TO PROVIDE ADEQUATE PROTECTION FOR
PERSONS AND PROPERTY AT ALL TIMES AND EXECUTE THE WORK IN SUCH A MANNER TO
AVOID ANY HAZARD TO PERSONS AND PROPERTY AS NECESSARY.
25. CONTRACTOR SHALL CONTINUOUSLY COORDINATE PHASING AND CONSTRUCTION WITH
THE CONTRACTING OFFICER AND DEPARTMENT OF PUBLIC WORKS.
26. CONTRACTOR SHALL COORDINATE WITH CONTRACTING OFFICER, AND EXISTING USER ON
LRC PORTION OF THE BUILDING ON CONSTRUCTION ACTIVITES, CONTRACTOR SHALL NOT
INTERFERE WITH LRC OPERATIONS.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
C
U s e rs
\e e n d c m g \D o c u m e n ts
\F o rt
H a m ilt o n B u ild in g
\M o d e l\ B
-D
M M
-A -M
D L .r v t
/2
/2
:4
:2
P
M
G-003
S H
E E
T L
IS
T
W
A
IN
W R
IG
H
T D
R B
R O
O K
L Y
N N
Y
N E
W Y
O R
K D
IS
T
R
IC
T F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
C .G
C .G
C .G
C .G
A U
G U
S T
W D
S -2
-B
-0
B L D
G
S T
M A
R
IN
E C
O R
P S
D
IS
T R
IC
T
R E
L O
C A
T
IO
N T
O F
T
H A
M
IL
T O
N N
Y
SHEET LIST
SHEET NUMBER Sheet Name
GENERAL
G-001 COVER SHEET
G-002 GENERAL NOTES
G-003 SHEET LIST
STRUCTURAL
S-101 STRUCTURAL DETAILS
LIFE SAFETY
FS-101 LIFE SAFETY ANALYSIS
FS-102 LIFE SAFETY ANALYSIS
FS-103 LIFE SAFETY PLAN
ARCHITECTURAL
1AB-101 ABATMENT PLAN
AD-101 DEMOLITION PLAN
AD-301 DEMOLITION SECTIONS
AD-302 DEMOLITION SECTIONS
AD-401 ENLARGED DEMOLITION PLAN 1
AD-402 ENLARGED DEMOLITION PLAN 2
AD-403 ENLARGED DEMOLITION PLAN 3
1A-104 ROOF PLAN OPTION
1A-202 ELEVATIONS OPTION
1A-504 ROOF DETAILS OPTION
A-101 FLOOR PLAN
A-102 REFLECTED CEILING PLAN
A-103 ROOM SCHEDULE
A-105 AIR BARRIER PLAN AND SECTIONS
A-201 ELEVATIONS
A-301 SECTIONS
A-302 SECTIONS
A-310 WALL SECTIONS
A-401 ENLARGED FLOOR PLAN 1
A-402 ENLARGED FLOOR PLAN 2
A-403 ENLARGED FLOOR PLAN 3
A-404 ENLARGED RESTROOM ABA STANDARD DETAILS
A-405 ENLARGED RESTROOM PLAN
A-406 ENLARGED RESTOOM PLAN 02
A-407 STANDARD MOUNTING HEIGHTS
A-408 RAMP AND STAIR
A-409 MILLWORK DETAILS
A-501 PARTITION TYPES
A-502 PARTITION DETAILS
A-503 DOOR DETAILS
A-504 WINDOW DETAILS
A-505 MECHANICAL PENETRATION DETAILS
A-509 MICELLANOUS DETAILS
A-601 DOOR SCHEDULE
A-602 WINDOW SCHEDULE
A-603 LOUVER SCHEDULE AND DETAILS
A-604 CEILING DETAILS
A-605 FINISH SCHEDULE
A-606 EXTERIOR SIGNAGE DETAILS
AR-101 ARCHITECTURAL REFERENCE DRAWINGS FLOOR PLAN/ ELEVATION
AR-300 ARCHITECTURAL REFERNCE DRAWINGS WALL SECTIONS AND DETAILS
INTERIOR DESIGN
I-101 PROPOSED FINISH PLAN
I-201 INTERIOR ELEVATIONS
I-401 ENLARGED FINISH PLAN 1
I-402 ENLARGED FINISH PLAN 2
I-403 ENLARGED FNISH PLAN 3
IF101 PROPOSED FURNITURE PLAN
IF401 ENLARGED FURNITURE PLAN 1
IF402 ENLARGED FURNITURE PLAN 2
IF403 ENLARGED FURNITURE PLAN 3
IG101 SIGNAGE TYPICALS
FIRE PROTECTION
FD101 FIRE PROTECTION DEMOLITION
FA001 FIRE ALARM GENERAL NOTES & LEGEND
FA101 FIRE ALARM FLOOR PLAN
FA501 FIRE ALARM DETAILS
FA601 FIRE ALARM RISER DIAGRAM
FA602 FIRE ALARM MATRIX
FX001 FIRE SUPPRESSION GENERAL NOTES & LEGEND
FX100 CODE COMPLIANCE SITE PLAN
FX101 FIRE SUPPRESSION FLOOR PLAN
FX401 FIRE SUPPRESSION LARGE SCALE PLANS & SECTIONS
FX501 FIRE SUPPRESSION DETAILS
FX601 FIRE SUPPRESSION RISER DIAGRAM
PLUMBING
P-001 LEGEND & ABBREVIATIONS
PD-100 PLUMBING DEMOLITION
P-101 PLUMBING OVERALL PLAN
P-102 PLUMBING SERVICE PIPING PLAN I
P-103 PLUMBING SERVICE PIPING PLAN II
P-104 SANITARY OVERALL PLAN
P-105 SANITARY PIPING PLAN I
P-106 SANITARY PIPING PLAN II
P-107 ROOF PLAN
P-501 PLUMBING DETAILS I
P-502 PLUMBING DETAILS II
P-503 PLUMBING DETAILS III
P-601 PLUMBING SCHEDULES
P-901 DOMESTIC RISER DIAGRAM
P-902 SANITARY RISER DIAGRAM
SHEET LIST
SHEET NUMBER Sheet Name
MECHANICAL
M-100 LEGEND & ABBREVIATIONS
MD-101 DEMOLITION PLAN MECHANICAL
MD-102 DEMOLITION PLAN MECHANICAL II AS-BUILT STEAM UNIT
HEATERS
MD-103 DEMOLITION PLAN MECHANICAL III
M-101 OVERALL DUCTWORK PLAN
M-102 DUCTWORK PLAN I
M-103 DUCTWORK PLAN II
M-104 DUCTWORK PLAN III
M-105 MECHANICAL PIPING PLAN I
M-106 MECHANICAL PIPING PLAN II
M-107 MECHANICAL PIPING PLAN III
M-108 VRF PIPING PROPOSED LAYOUT 1
M-109 VRF PIPING PROPOSED LAYOUT 2
M-110 VRF PIPING PROPOSED LAYOUT 3
M-401 MECHANICAL NATURAL GAS CONNECTION
M-501 MECHANICAL DETAILS I
M-502 MECHANICAL DETAILS II
M-503 MECHANICAL DETAILS III
M-601 MECHANICAL SCHEDULE I
M-602 MECHANICAL SCHEDULE II
M-603 MECHANICAL SCHEDULE III
M-604 MECHANICAL SCHEDULE IV
M-605 MECHANICAL SCHEDULE V
M-701 SEQUENCE OF OPERATIONS
M-702 MECHANICAL CONTROL POINTS 1
M-703 MECHANICAL CONTROL POINTS 2
M-704 MECHANICAL CONTROL POINTS 3
M-705 MECHANICAL CONTROL POINTS 4
M-706 MECHANICAL CONTROL POINTS 5
M-801 MECHANICAL SCHEMATICS
ELECTRICAL
E001 ELECTRICAL - NOTES, LEGEND, AND ABBREVIATIONS
E003 SECURITY - NOTES, LEGEND, AND ABBREVIATIONS
E004 ELECTRICAL - TYPICAL DEVICE MOUNTING HEIGHTS
ED101 ELECTRICAL - DEMOLITION SITE PLAN
ED102 ELECTRICAL - DEMOLITION FLOOR PLAN
1EG101 GROUNDING AND LIGHTNING PROTECTION PLAN - ROOF
1EG501 GROUNDING AND LIGHTNING PROTECTION - DETAILS
EL101 LIGHTING - AREA A
EL102 LIGHTING - AREA B
EL103 LIGHTING - AREA C
EL501 LIGHTING - DETAILS
EL601 LIGHTING - LIGHTING FIXTURE SCHEDULE
EL701 LIGHTING - LIGHTING CONTROLS DIAGRAM
EP101 POWER - AREA A
EP102 POWER - AREA B
EP103 POWER - AREA C
EP401 POWER - PART PLANS AND ELEVATIONS
EP601 POWER - ONE LINE DIAGRAM
EP701 POWER - PANEL SCHEDULES
EP702 POWER - PANEL SCHEDULES
EP703 POWER - PANEL SCHEDULES
EP704 POWER - PANEL SCHEDULES
EP705 POWER - PANEL SCHEDULES
ES101 ELECTRICAL - SITE PLAN - POWER
ES501 ELECTRICAL - SITE POWER DETAILS
EY501 SECURITY - DETAILS
EY502 SECURITY - DETAILS
TELECOMMUNICATIONS
E002 COMMUNICATIONS - NOTES, LEGEND, AND ABBREVIATIONS
ET101 TELECOM AND SECURITY - AREA A
ET102 TELECOM AND SECURITY - AREA B
ET103 TELECOM AND SECURITY - AREA C
ET501 TELECOM - DETAILS
ET502 TELECOM - DETAILS
| Sheets |
| A-101 - FLOOR PLAN |
| A-403 - ENLARGED FLOOR PLAN 3 |
| A-501 - PARTITION TYPES |
| AD-101 - DEMOLITION PLAN |
| AD-403 - ENLARGED DEMOLITION PLAN 3 |
| G-001 - COVER SHEET |
| G-002 - GENERAL NOTES |
| G-003 - SHEET LIST |
File details come from the government source that posted it. Updated .