E-002 and ED102 Amd 3.pdf
PDF 352 KB Posted
- Solicitation number
- W912DS23B0022
About this file
This document package includes construction drawings and notes for the renovation of Building 125 at Fort Hamilton in Brooklyn, New York. The drawings show demolition plans to remove electrical and communications systems from areas outside the scope of work, as well as notes specifying maintenance of power and connections to unaffected areas. Renovation will include new pathways, cabling, device plates, boxes and racks. The opportunity is a solicitation from the U.S. Army Corps of Engineers Engineering District New York to renovate Building 125 for the 1st Marine Corps District Relocation to Fort Hamilton. The solicitation number is W912DS23B0022.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
J
INTERIOR COMMUNICATIONS LEGEND ABBREVIATIONS AND ACRONYMS
ACPP AC POWER PANEL
ASP, ASPH ASPHALT OR BITUMINOUS
B&B BRICK AND BLOCK
BE BUILDING ENTRANCE
BET BUILDING ENTRANCE TERMINAL
BKBD BACKBOARD
C&R CUT AND RESURFACE
CAA CONTROLLED ACCESS AREA
CAB CABINET
CAT CATEGORY (I.E., 5, 5E, 6, ETC.)
CC CENTER TO CENTER
CKT CIRCUIT
CL CUT LENGTH
CONC CONCRETE
CONV CONVERTER (I.E., MEDIA CONVERTER)
CTTA CERTIFIED TEMPEST TECHNICAL AUTHORITY
CU COPPER
CW ENTER TO WALL
DIA DIAMETER
EXS EXISTING
FE FAST ETHERNET
FO FIBER OPTIC
FOC FIBER OPTIC CABLE
GND GROUNDING
HH HANDHOLE
HR HOUR
IAW IN ACCORDANCE WITH
LCA LIMITED CONTROLLED ACCESS
L2 LAYER 2 (CORRESPONDING TO OSI MODEL)
L3 LAYER 3 (CORRESPONDING TO OSI MODEL.)
L4 LAYER 4 (CORRESPONDING TO OSI MODEL.)
LGE LARGE
LOC LOCATION
MAX MAXIMUM
MECH RM MECHANICAL ROOM
MED MEDIUM
MH MAINTENANCE HOLE
MIN MINIMUM
MM MULTIMODE
MTR MAIN TELECOMMUNICATIONS ROOM
NEC NETWORK ENTERPRISE CENTER
NIC NOT IN CONTRACT
NOM NOMINAL
OC ON CENTER
OSP OUTSIDE PLANT
PED PEDESTAL
PP PATCH PANEL; POINT TO POINT
PR PAIR
PVC POLYVINYL CHLORIDE
PWR POWER
RM ROOM
SHT SHEET
SM SINGLE MODE
SMFOC SINGLE MODE FIBER OPTIC CABLE
SML SMALL
ST, STR STRAND(S)
STP SHIELDED TWISTED PAIR
TERM TERMINATE
TGB TELECOMMUNICATIONS GROUND BUSBAR
TMGB TELECOMMUNICATIONS MAIN GROUND BUSBAR
TR TELECOMMUNIATIONS ROOM
TS TOP SECRET
TTB TELEPHONE TERMINAL BACKBOARD
UL UNDERWRITERS LABORATORY
UTP UNSHIELDED TWISTED PAIR
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
WL WORK LOCATION
x 2 PROVIDE NUMBER OF DEVICES INDICATED TIMES THE NUMBER
INDICATED.
TELECOMMUNICATIONS MAIN GROUNDING BUS BAR
INCOMING CONDUIT
OUTGOING CONDUIT
LADDER CABLE TRAY
COMMUNICATIONS/AV EQUIPMENT RACK (ROUGH-IN ONLY)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
REFER TO SHEETS E001 AND E003 FOR ADDITIONAL SYMBOLS ABBREVIATIONS
AND NOTES.
NOT USED.
DRAWINGS FOR THIS WORK ARE DIAGRAMMATIC AND INTENDED TO CONVEY
THE EXTENT, GENERAL ARRANGEMENT AND LOCATION OF THE WORK. DUE TO
THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS SUCH AS CONDUIT
FITTINGS, ACCESS PANELS, CABINET SIZES, SLEEVES, PULL BOXES,
BACKBOXES, AND JUNCTION BOXES MAY NOT BE SHOWN. WHETHER SHOWN
OR NOT, INCLUDE ALL ITEMS REQUIRED BY CODE, PLANS AND SPECIFICATIONS
FOR PROPER INSTALLATION AND OPERATION OF THE SYSTEM.
COMMUNICATIONS WORK SHALL CONFORM TO ALL APPLICABLE NATIONAL,
STATE AND LOCAL BUILDING CODES AND SHALL BE IN ALLIANCE WITH BICSI
STANDARDS, U.S. ARMY TECHNICAL CRITERIA FOR INSTALLATION INFORMATION
INFRASTRUCTURE ARCHITECTURE (I3A) AND UFC 3-580-01.
DO NOT SCALE ANY DRAWINGS. DIMENSIONS TAKEN FROM CENTERLINE OF
DEVICE OR GANG BOX SHALL BE FOLLOWED. COMMUNICATIONS DEVICES ARE
SHOWN FOR LOCATION AND TYPE ONLY.
ALL CONDUIT RUNS SHALL BE EQUIPPED WITH A PULL STRING WITH MINIMUM
TEST RATING OF 200 LB.
NO ONE CONDUIT SEGMENT SHALL BE MORE THAN 100' WITHOUT THE
INSERTION OF A PULL BOX.
AT NO TIME SHALL A CONDUIT RUN EXCEED (2) 90° BENDS WITHOUT THE
INSERTION OF A PULL BOX.
COMMUNICATION RACKS ARE GFGI. ALL COMMUNICATION RACKS SHALL BE
PROVIDED WITH VERTICAL WIRE MANAGERS.
WHERE ROUTING OF RACEWAY/CONDUIT IS SHOWN ON PLANS TO PASS
THROUGH WALLS AND PARTITIONS, CORE DRILL PENETRATIONS UNLESS
SPECIFICALLY NOTED OTHERWISE. SIMILAR CUTTING AND PATCHING TO MATCH
EXISTING SURFACES SHALL BE UTILIZED WHERE CONDITIONS PERMIT.
COMMUNICATIONS SCOPE IS PATHWAYS, CABLING, DEVICE PLATES, JUNCTION
BOXES, BACK BOXES, PATCH PANELS, AND RACK-MOUNTED UPS.
GENERAL NOTES
A101
CEILING MOUNTED JUNCTION BOX FOR SYSTEMS FURNITURE
COMMUNICATIONS FEED.
S RECESSED CEILING MOUNTED SPEAKER (ROUGH-IN ONLY)
ANNOTATION LEGEND
DETAIL NUMBER
SHEET LOCATION OF REFERENCE
NOTE 1 DRAWING NOTE - REFER TO DRAWING NOTE
NUMBER INDICATED FOR ADDITIONAL
INFORMATION.
WELDED WIRE CABLE TRAY
VOICE/DATA OUTLET. 'X' INDICATES NUMBER OF CAT6 CONECTORS
(RJ-45).
CABLE TELEVISION OUTLET. PROVIDE (1) CONNECTOR FOR COAXIAL
CABLING.
x c
WALL MOUNTED JUNCTION BOX FOR SYSTEMS FURNITURE
COMMUNICATIONS FEED.
OVER THE CARPET RACEWAY FLOORBOX. PROVIDE (8) RJ-45
CONNECTORS FOR CAT-6 CABLING.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M Y C O R
PS
O F
EN
G
IN
EE
R S
D R
AW
N B Y:
D
ES
IG
N
ED
B Y:
SU
BM
IT
TE
D B Y:
SI
ZE
C H
EC
KE
D B Y:
AN
SI
D
IS
SU
E D
AT
E:
C O N
TR
AC
T N O
SO
LI
C
IT
AT
IO
N N O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
E002
C O M M U N
IC
AT
IO
N S
- N
O
TE
S, L
EG
EN
D , A
N D
AB
BR
EV
IA
TI
O N S
W ai nw rig ht D r., B ro ok ly n, N Y
N
EW
Y O R K D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
N
EW
Y O R K, N Y
D es ig ne r
Au th or
C he ck er
J U N E
Pr oj ec t N am e Bl dg . 1 , 1 st M ar in e C or ps D is tri ct R el oc at io n to F t.
H am ilt on , N
Y c c
R
EV
IS
ED
B Y
AM
EN
D M
EN
T
/3 1/
DN DN
DNDN
M
TS
B
A
1 2 3 4 5 6 87
NOT IN PROJECT SCOPE DPW FAMILY HOUSING DTMS POST CAGES THRIFT SHOP
WALK-IN BOX
MECHANICAL ROOM
BASKETBALL COURT
SCOPE OF WORK
1 2 3 4
GENERAL NOTES:
1. REFER TO SHEETS E001, E002, AND E003 FOR ELECTRICAL SYMBOLS,
ABBREVIATIONS, AND GENERAL NOTES.
2. THIS DRAWING IS PROVIDED FOR INFORMATION PURPOSES ONLY AND IS NOT
INTENDED TO INDICATE ALL DEMOLITION WORK. CONTRACTOR IS
RESPONSIBLE FOR VERIFYING QUANTITIES AND LOCATIONS FOR ALL ITEMS.
3. MAINTAIN CONTINUITY TO AREAS NOT AFFECTED BY DEMOLITION.
4. ALL CIRCUITS FEEDING THE NOT IN SCOPE AREA SHALL BE GENERATED FROM
EXISTING MECHANICAL ROOM. CONTRACTOR SHALL EXTEND ALL EXISTING
WIRES AND CONDUITS TO THE NEW PANEL "LRC1" LOCATED IN THE NEW
ELECTRICAL ROOM.CONTRACTOR IS RESPONSIBLE TO PROVIDE THE
REQUIRED CIRCUIT BREAKERS IN THE NEW PANELBOARD "LRC1".
IT IS THE CONTRACTOR'S RESPONSIBILITY TO SURVEY EXISTING TO REMAIN
CIRCUITS AND TO ENSURE THERE IS SUFFICIENT SPACE IN PANEL "LRC1"
TO ACCOMMODATE ALL EXISTING LOADS.
5. FOR NOT IN SCOPE AREAS, CONTRACTOR IS RESPONSIBLE TO PROVIDE
TEMPORARY POWER DURING CONSTRUCTION. CONTRACTOR IS ALSO
RESPONSIBLE TO MAINTAIN ALL EXISTING CONNECTIONS SUCH AS BUT NOT
LIMITED TO DATA, PHONES, SECURITY, ETC. FOR ALL AREAS NOT AFFECTED BY
THIS DEMOLITION WITHOUT DISTURBING TENANTS.
6. GENERATOR SHALL NOT BE USED FOR TEMPORARY POWER.
7. COMMUNICATION RACKS ARE GOVERNMENT FURNISHED CONTRACTOR INSTALLED.
KEYNOTES:
1. REMOVE ALL RECEPTACLES AND ASSOCIATED CONDUIT AND WIRING
BACK TO SOURCE.
2. REMOVE ALL LIGHTING FIXTURES, SWITCHES, EMERGENCY LIGHTING
FIXTURES, EXIT SIGNS AND ASSOCIATED CONDUIT BACK TO SOURCE.
3. REMOVE ALL ASSOCIATED DISCONNECTING MEANS, STARTERS, AND
CONDUIT IN EXISTING MECHANICAL ROOM BACK TO SOURCE.
4. REMOVE ALL TELECOMMUNICATIONS DEVICES AND ASSOCIATED
CABLING AND CONDUIT BACK TO SOURCE.
5. ALL INFRASTRUCTURE AND EQUIPMENT IN EXISTING TELECOM ROOM
TO REMAIN. CONTRACTOR TO COORDINATE WITH DPW AND LRC TO
MAINTAIN EXISTING CONNECTIONS TO THE AREAS NOT AFFECTED BY
THIS DEMOLITION.
6. EXISTING MAIN DISTRIBUTION, PANELBOARD, AND MANUAL TRANSFER
SWITCH IN MECHANICAL ROOM TO BE DEMOLISHED.
7. EXISTING PANELBOARDS TO BE DEMOLISHED.
8. EXISTING SERVICE CONDUIT AND WIRING TO BE DEMOLISHED.
9. CONTINUATION FROM ED101.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
ED102
EL
EC
TR
IC
AL
D
EM
O
LI
TI
O
N F
LO
O
R P
LA
N
W ai nw rig ht D r., B ro ok ly n, N Y
N
EW
Y
O R
K D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
N
EW
Y O
R K, N Y
D es ig ne r
Au th or
C he ck er
J
U N
E
Pr oj ec t N am e Bl dg . 1
, 1 st M ar in e C or ps
D is tri ct
R el oc at io n to F t.
H am ilt on , N
Y
/3 1/
1/16" = 1'-0"1 FLOOR PLAN - DEMOLITION
0 8' 16' 32'
SCALE: 1/16" = 1'-0"
N
R
EV
IS
ED
B Y
AM
EN
D M
EN
T
| E-002 Amd 3 |
| Sheets: E002 - COMMUNICATIONS - NOTES, LEGEND, AND ABBREVIATIONS |
| ED102 Amd 3 |
| Sheets: ED102 - ELECTRICAL - DEMOLITION FLOOR PLAN |
File details come from the government source that posted it. Updated .