A-501 20230831.pdf

PDF 150 KB Posted

Attached to
Renovate Bldg. 125 Fort Hamilton, Brooklyn, New York
Solicitation number
W912DS23B0022
Issued by

About this file

This document contains construction drawings and specifications for partition types in the renovation of Building 125 at Fort Hamilton in Brooklyn, New York. The drawings show various metal stud and drywall composite wall assemblies at different thicknesses with UL, fire rating, and STC acoustic performance details. Related specifications include a solicitation by the U.S. Army Corps of Engineers Engineering District New York to renovate Building 125 under Solicitation Number W912DS23B0022 with a response due date of August 2023 and work to be completed under Contract Number W912DS-23-B-0022.

View the file

Other files

File Type Posted
C.04.01 Bid Abstract Bldg 125 Final.pdf PDF
A-605 and S-102 S-103 Amd 5.pdf PDF
B.08.03 Amendment 05.pdf PDF
09 06 00 Amd 5.pdf PDF
10 21 13 Amd 5.pdf PDF
E-002 and ED102 Amd 3.pdf PDF
LEED_v4_for_Interior_Design_and_Construction_Checklist B125 Reno Ft Hamilton.pdf PDF
Army_SustainabilityReportCard_2020 B125 Renovation LEED IDC.pdf PDF
Fort Hamilton Planning Charrete.pdf PDF
M-101 thru 107 (rev 02) and 602 (rev 01) Amd 5.pdf PDF
07 27 10 Amd 5.pdf PDF
12 50 00.13 FFE Data Sheet Item Code M4 revised.pdf PDF
01 33 29 Amd 5.pdf PDF
B.08.03 Amendment 04.pdf PDF
B.08.03 Amendment 03.pdf PDF
A-405 20230830.pdf PDF
A-408 20230830.pdf PDF
1AB-101 20230830.pdf PDF
A-605 20230831.pdf PDF
A-101 A-403 A-501 AD-101 AD-403 20230829.pdf PDF
Renovation BLDG 125-Mechanical Room - Sheet - M-111 - MECHANICAL ROOM PLAN.pdf PDF
B.08.03 Amendment 02.pdf PDF
A-602 Amendment 2 20230823.pdf PDF
Amendment 2 Mechanical Drawings M102 thru 107 M601 M701.pdf PDF
A-404 Amendment 2 20230824.pdf PDF
A-601 Amendment 2 20230823.pdf PDF
B.08.03 Amendment 01.pdf PDF
B.08.03 Site Visit Sign in sheet_16 Aug 23 (002).jpg JPG image
B.08.03 Invitation for Bid W912DS23B0022.pdf PDF
JA_Hamilton_125_Simplex Signed.pdf PDF
Fort Hamilton Bldg 125-100_PCNT_Specification_07-31-2023.pdf PDF
B.08.03 Invitation for Bid W912DS23B0022.pdf PDF
B125 RTA Complete set R4 07 August 2023.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LIGHT GAUGE STUD & GYP. BD.

COMPOSITE ASSEMBLY A

CHASE WALL

NON-COMP. BRACED AT 48 IN. O.C.C

A01

3 5/8" METAL STUD

5/8" GYPSUM BD. - BOTH SIDES

ACTUAL THICKNESS - 4 7/8"

UL: NONE

FIRE RATING: NONE

STC RATING: 52

CF1

(2) 3 5/8" METAL STUD

5/8" GYPSUM BD. - BOTH SIDES

8" AIR SPACE

ACTUAL THICKNESS - 1'-4 1/2" MIN.

UL: NONE

FIRE RATING: NONE

STC RATING: 52

TO STRUCTURE ABOVE

METAL STUD

METAL RUNNER CHANNEL

GYP. BOARD

CEILING

METAL RUNNER CHANNEL

ROOF DECK

GYP. BOARD

METAL STUD

CEILING

METAL RUNNER

CHANNEL

ROOF DECK

METAL RUNNER CHANNEL

A02

3 5/8" METAL STUD

5/8" GYPSUM BD. - BOTH SIDES

ACTUAL THICKNESS - 4 7/8"

UL: DES NO. U419

FIRE RATING: 1 HR

STC RATING: 52 (RAL-TL11-125)

CHASE WALL ON EXTERIOR WALL

CEILING

ROOF DECK

8" AIR SPACE

GYP. BOARD

METAL STUD

F

F01

3 5/8" METAL FURRING (ONE SIDE)

5/8" GYPSUM BD. (ONE SIDE)

8" AIR SPACE

ACTUAL THICKNESS - 1' 1/4"

UL: NONE

FIRE RATING: NONE

STC RATING: 52 (RAL-TL11-125)

METAL RUNNER CHANNEL

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

U s e rs

\e e n d c m g \D o c u m e n ts

\F o rt

H a m ilt o n B u ild in g

\M o d e l\ B

-D

M M

-A -M

D L .r v t

/3

/2

:1

:0

P

M

A-501

P A

R T

IT

IO

N T

Y P

E S

W

A

IN

W R

IG

H

T D

R B

R O

O K

L Y

N N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

C .G

C .G

C .G

C .G

A U

G U

S T

W D

S -2

-B

-0

B L D

G

S T

M A

R

IN

E C

O R

P S

D

IS

T R

IC

T

R E

L O

C A

T

IO

N T

O F

T

H A

M

IL

T O

N N

Y

D e ta ils A d d e d t o D ra w in g s /N o te s a d d e d t o d ra w in g s

/3 /2

GENERAL NOTES

1. IN TRUSS ROOF SYSTEMS NON FIRE RATED PARTITIONS ARE TO BE

TERMINATED AT BOTTOM OF STRUCTURE

Sheets
A-501 - PARTITION TYPES

File details come from the government source that posted it. Updated .