This document is a window schedule and related drawings for the renovation of Building 125 at Fort Hamilton in Brooklyn, New York. The window schedule provides details on three fixed aluminum window types to be installed, including dimensions for width, height, sill height and head height. It notes the contractor shall field verify all openings and adjust window height based on a new precast concrete sill. The schedule also references related specification sections for anchoring, glazing and window details. The solicitation number for the project is W912DS23B0022 and it is being conducted by the Department of the Army Corps of Engineers New York District for the relocation of the 1st Marine Corps District headquarters to Fort Hamilton.

View the file

Other files

File Type Posted
C.04.01 Bid Abstract Bldg 125 Final.pdf PDF
A-605 and S-102 S-103 Amd 5.pdf PDF
B.08.03 Amendment 05.pdf PDF
09 06 00 Amd 5.pdf PDF
10 21 13 Amd 5.pdf PDF
E-002 and ED102 Amd 3.pdf PDF
LEED_v4_for_Interior_Design_and_Construction_Checklist B125 Reno Ft Hamilton.pdf PDF
Army_SustainabilityReportCard_2020 B125 Renovation LEED IDC.pdf PDF
Fort Hamilton Planning Charrete.pdf PDF
M-101 thru 107 (rev 02) and 602 (rev 01) Amd 5.pdf PDF
07 27 10 Amd 5.pdf PDF
12 50 00.13 FFE Data Sheet Item Code M4 revised.pdf PDF
01 33 29 Amd 5.pdf PDF
B.08.03 Amendment 04.pdf PDF
B.08.03 Amendment 03.pdf PDF
A-405 20230830.pdf PDF
A-408 20230830.pdf PDF
A-501 20230831.pdf PDF
1AB-101 20230830.pdf PDF
A-605 20230831.pdf PDF
A-101 A-403 A-501 AD-101 AD-403 20230829.pdf PDF
Renovation BLDG 125-Mechanical Room - Sheet - M-111 - MECHANICAL ROOM PLAN.pdf PDF
B.08.03 Amendment 02.pdf PDF
Amendment 2 Mechanical Drawings M102 thru 107 M601 M701.pdf PDF
A-404 Amendment 2 20230824.pdf PDF
A-601 Amendment 2 20230823.pdf PDF
B.08.03 Amendment 01.pdf PDF
B.08.03 Site Visit Sign in sheet_16 Aug 23 (002).jpg JPG image
B.08.03 Invitation for Bid W912DS23B0022.pdf PDF
JA_Hamilton_125_Simplex Signed.pdf PDF
Fort Hamilton Bldg 125-100_PCNT_Specification_07-31-2023.pdf PDF
B.08.03 Invitation for Bid W912DS23B0022.pdf PDF
B125 RTA Complete set R4 07 August 2023.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

V .I

.F

V .I .F

10' - 0"

3' - 9"

W1 W2

PROPOSED

PRECAST SILL

PROPOSED

PRECAST SILL

V .I

.F

7' - 10"

W3

PROPOSED

PRECAST SILL

0 2' 4' 8'

SCALE: 1/4" = 1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

U s e rs

\e e n d c m g \D o c u m e n ts

\F o rt

H a m ilt o n B u ild in g

\M o d e l\ B

-D

M M

-A -M

D L .r v t

/2

/2

:4

:3

P

M

A-602

W

IN

D O

W S

C H

E D

U L E

W

A

IN

W R

IG

H

T D

R B

R O

O K

L Y

N N

Y

N E

W Y

O R

K D

IS

T

R

IC

T F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

C .G

C .G

C .G

C .G

A U

G U

S T

W D

S -2

-B

-0

B L D

G

S T

M A

R

IN

E C

O R

P S

D

IS

T R

IC

T

R E

L O

C A

T

IO

N T

O F

T

H A

M

IL

T O

N N

Y

A d ju s tm e n t in

W in d o w s a n d D o o r

S c h e d u le

/2

/2

WINDOW SCHEDULE

Count Mark

R.O.

Operation

FRAME DETAILS

Sill Height Head Height Remarks (See Notes Below)Width Height Material Head Jamb Window_Sill W1

17 W1 3' - 9" 3' - 0" FIXED ALUM 1 2 3 9' - 0" 12' - 0"

W2

3 W2 10' - 0" 3' - 0" FIXED ALUM 1 2 3 9' - 0" 12' - 0"

W3

2 W3 7' - 10" 4' - 7" FIXED ALUM 1 2 3 3' - 6" 8' - 1"

GENERAL NOTES:

1. CONTRACTOR WILL FIELD VERIFY ALL OPENINGS WITH NEW

PRECAST CONCRETE SILL AND ADJUST WINDOW HEIGHT

ACCORDINGLY

2. GROUT FILL ANY INLETS WITHIN THE CMU FROM EXISTING

WINDOW FRAMES

3. SEE A-504 FOR WINDOW DETAILS

4. REFER TO FLOOR PLANS AND ELEVATIONS FOR LOCATION OF

ALL WINDOWS

5. REFER TO SPECIFICATIONS FOR ANCHORING REQUIREMENTS

6. FIELD VERIFY ALL OPENINGS PRIOR TO WINDOW FABRICATION

7. REFER TO GLAZING SPEC FOR GLASS TYPE AND THICKNESS

8. REFER TO DRAWING A-607 FOR WINDOW DETAILS

1/4" = 1'-0"

WINDOW TYPES

Sheets
A-602 - WINDOW SCHEDULE