1. THE CONTRACTOR SHALL CONDUCT ALL OPERATIONS IN STRICT ACCORDANCE WITH
THE SAFETY REQUIREMENTS IMPOSED BY THE OWNER AND OSHA. IT IS SOLELY THE
CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND
REGULATIONS GOVERNING THIS WORK. THE CONTRACTOR SHALL REMOVE ALL DEBRIS
FROM THE OWNER'S PROPERTY AND DISCARD ACCORDING TO LOCAL REGULATIONS.
2. THIS STRUCTURE HAS BEEN BE DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER
IT IS FULLY COMPLETED. THE MANUFACTURERS OF ALL STRUCTURAL PARTS UTILIZED
IN THIS PROJECT SHALL ENSURE THAT ALL DESIGN AND LOAD REQUIREMENTS ARE
CONSIDERED AND SATISFIED IN THE FINAL APPROVED DESIGN. THE CONTRACTOR IS
SOLELY RESPONSIBLE TO DETERMINE THE ERECTION PROCEDURES AND SEQUENCES
REQUIRED TO ENSURE STABILITY OF THE STRUCTURE AND ITS COMPONENT PARTS
DURING CONSTRUCTION. THIS CONSTRUCTION STABILITY REQUIREMENT APPLIES
CONTINUOUSLY AND IS NOT LIMITED TO NORMAL WORKING HOURS.
3. SHOP DRAWINGS REQUIRED BY THE PROJECT SPECIFICATIONS AND PREPARED BY
SUPPLIERS AND/OR SUBCONTRACTORS SHALL BE REVIEWED AND STAMPED BY THE
GENERAL CONTRACTOR PRIOR TO SUBMISSION TO THE STRUCTURAL ENGINEER. ALL
DEVIATIONS FROM THE ENGINEERING DRAWINGS SHALL BE CIRCLED AND NOTED ON
THE SHOP DRAWINGS BY THE CONTRACTOR. THE SCOPE OF THE STRUCTURAL
ENGINEER'S REVIEW WILL BE LIMITED TO CHECKING CONTRACTOR'S GENERAL
CONFORMANCE WITH THE CONTRACT DOCUMENTS AND DESIGN CONCEPT. NO SHOP
WORK IS PERMITTED TO COMMENCE UNTIL THE RETURN OF THE SHOP DRAWINGS BY
THE GENERAL CONTRACTOR.
4. ALL DETAILS, SECTIONS, AND NOTES PROVIDED ON STRUCTURAL DRAWINGS ARE
INTENDED TO BE TYPICAL FOR SIMILAR SITUATIONS ELSEWHERE, UNLESS
SPECIFICALLY NOTED OTHERWISE. FOR ANY DETAILS AND DIMENSIONS NOT PROVIDED,
REFER TO ARCHITECTURAL DRAWINGS. ALL DIMENSIONS AND ELEVATIONS SHOWN ON
STRUCTURAL DRAWINGS ARE INTENDED TO CONFORM WITH THE INFORMATION
PROVIDED ON ARCHITECTURAL DRAWINGS. THE CONTRACTOR SHALL REPORT ANY
DISCREPANCIES TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR RESOLUTION
BEFORE PROCEEDING WITH ANY ADDITIONAL WORK.
5. EXISTING UTILITIES AND ALL OTHER OBSTRUCTIONS TO WORK SHALL BE TEMPORARILY
REMOVED AND RE-INSTALLED (INCLUDING NECESSARY MODIFICATIONS) BY THE
CONTRACTOR AFTER COMPLETION OF NEW WORK.
6. OPENING SIZES AND LOCATIONS FOR PIPES, DUCTS, ETC., WHEN DIMENSIONED ON THE
PROJECT DRAWINGS, SHALL BE INSTALLED IN SUCH LOCATION AND SIZE. WHEN SHOWN
WITHOUT DIMENSIONS, SIZES AND LOCATIONS ARE SHOWN FOR GENERAL
INFORMATION ONLY. REFER TO RELATED DRAWINGS (ARCH., MECH., ELECT, ETC.) FOR
OTHER POSSIBLE EQUIPMENT SUPPORTS; WALL, FLOOR AND ROOF OPENINGS; SLEEVES;
AND OTHER EMBEDDED ITEMS NOT SPECIFICALLY INDICATED ON STRUCTURAL DRAWINGS.
COORDINATE ALL REQUIRED DIMENSIONS WITH APPLICABLE TRADE CONTRACTORS PRIOR
TO ANY STEEL FABRICATION OR CONCRETE PLACEMENT. ANY OPENINGS REQUIRED TO
BE LARGER THAN OPENINGS SHOWN SHALL BE VERIFIED PRIOR TO CONSTRUCTION.
7. ALL FRAMING MEMBERS PROVIDED ON THE DRAWINGS FOR STRUCTURAL SUPPORT,
MECHANICAL TRADES, ELEVATOR SUPPORT BEAMS, LINTELS, ROOF OPENINGS, ETC.
ARE FOR BIDDING PURPOSES ONLY. THE CONTRACTOR SHALL SUBMIT MANUFACTURER'S
DESIGN DATA FOR THE PROPOSED SUPPORTS AND EQUIPMENT PRIOR TO STEEL SHOP
DRAWING SUBMITTAL, FOR APPROVAL FROM THE STRUCTURAL ENGINEER.
8. CONSTRUCTION TRAFFIC SHALL BE LIMITED ON EXPOSED SUBGRADES, ESPECIALLY
DURING WETTER PERIODS/SEASONS OF THE YEAR. THE IN-SITU SUBGRADE SOILS ARE
SLIGHTLY MOISTURE SENSITIVE AND MAY BECOME UNSTABLE UNDER REPETITIVE
CONSTRUCTION TRAFFIC.
ALL CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF THE CURRENT ACI 301,
"SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS", WITH THE FOLLOWING
SUPPLEMENTAL REQUIREMENTS:
1. CONCRETE SHALL BE NORMAL WEIGHT, WITH AGGREGATES CONFORMING TO ASTM C33,
EXCEPT FOR THE COMPOSITE FLOOR DECK WHICH SHALL BE LIGHTWEIGHT CONCRETE.
2. CONCRETE SHALL DEVELOP THE FOLLOWING 28-DAY COMPRESSIVE STRENGTH (F'c):
ELEVATED COMPOSITE FLOOR & ROOF SLABS 2500 PSI, LIGHT WEIGHT
COLUMN PIERS, FOUNDATION WALLS 4500 PSI, NORMAL WEIGHT
SLAB ON GRADE 4500 PSI, NORMAL WEIGHT
ALL OTHER STRUCT. CONCRETE WORK UNO 4000 PSI, NORMAL WEIGHT
3. REINFORCING:
TYPICAL - ASTM A615, GRADE 60
REINFORCING TO BE WELDED - ASTM A706 (INCLUDES DEFORMED BAR ANCHORS)
WELDED WIRE FABRIC - ASTM A185 (FLAT SHEETS ONLY)
4. GROUT UNDER BASE PLATES SHALL BE HIGH STRENGTH (5000 PSI), AND SHALL BE A NON-
METALLIC, NON-SHRINK, NON-GAS FORMING, EXPANSIVE TYPE.
5. PROVIDE 3/4" BEVELS AT CORNERS OF ALL COLUMNS, EDGES OF EXPOSED BEAMS, AND TOP
EDGES AND CORNERS OF EXPOSED WALLS.
6. CONSTRUCTION JOINTS IN CONCRETE ELEMENTS SHALL BE SUBMITTED TO THE S.E.O.R. FOR
REVIEW AND APPROVAL IN THE SHOP DRAWING SUBMITTAL PHASE. ALL REINFORCING SHALL
BE CONTINUOUS THROUGH THE CONSTRUCTION JOINTS.
7. CHLORIDE BASED ADMIXTURES ARE PROHIBITED IN ALL REINFORCED CONCRETE. OTHER
ADMIXTURES SHALL CONFORM TO ASTM C494.
8. MAXIMUM SLUMP SHALL BE 4" +/- 1", AS DETERMINED IN ACCORDANCE WITH ASTM C143.
9. AIR ENTRAIN ALL CONCRETE EXPOSED TO WEATHER 5 1/2% +/- 1 1/2%.
10. PITS SHALL BE PLACED MONOLITHICALLY WITH GRADE BEAMS AND WALLS UNLESS PRIOR
WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER TO PLACE THEM
SEPARATELY.
11. CJ SHOWN ON PLAN INDICATES EITHER SLAB CONTRACTION JOINT OR CONSTRUCTION
JOINT AT CONTRACTOR'S OPTION. SLAB CONTRACTION JOINTS SHALL BE A 1/8" WIDE
SAWCUT (MINIMUM OF 1/4 OF SLAB DEPTH). SLAB CONSTRUCTION JOINTS SHALL HAVE 3/4"
DIAMETER SMOOTH DOWELS, 18" LONG, 12" O.C. CENTERED IN SLAB.
12. ALL REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 OR
A996 GRADE 60. ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185, AND
BE FURNISHED IN FLAT SHEETS.
13. CONCRETE CLEAR COVER FOR REINFORCING STEEL FROM FACE OF CONCRETE:
CAST IN PLACE CONCRETE (MEASURE TO OUTERMOST REINFORCING):
WALLS, PEDESTALS 2"
FOOTINGS 3"
SLABS EXPOSED TO EARTH AND WEATHER 1-1/2"
GRADE BEAMS (EDGE OF STIRRUPS) 2" TOP, 3" BOT, 3" SIDES
14. ALL HOOK BARS SHALL CONTAIN 90 DEGREE ACI STANDARD HOOKS UNLESS NOTED
OTHERWISE. HOOKS MAY BE ROTATED TO MAINTAIN CLEARANCES. ALL BAR SPLICES
AND LAPS, WHEN NOT SPECIFICALLY DIMENSIONED ON DRAWINGS, SHALL BE AS PER
ACI STANDARD REQUIREMENTS. CLASS B LAPS SHALL BE USED UNLESS OTHERWISE
NOTED. CLOSED STIRRUPS MAY BE CONSTRUCTED IN TWO PIECES, 135 DEGREE HOOKS
SHALL BE USED.
15. REFER TO THE DRAWINGS FOR REINFORCING LAP REQUIREMENTS. WHERE LAP SPLICES
ARE NOT SHOWN, LAP PER ACI 318 OR CRSI STANDARDS.
16. LAP WELDED WIRE FABRIC SHEETS PER SPECIFICATION SECTION 03 20 01.
17. PROVIDE HORIZONTAL EXTERIOR CORNER BARS WITH SAME SIZE AND SPACING AS WALL
REINFORCING BARS, UNLESS NOTED OTHERWISE.
18. ALL REINFORCING STEEL TO BE DEFORMED SHALL ADHERE TO ASTM A615 OR A996 GRADE 60.
ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND BE FURNISHED IN FLAT SHEETS
19. PROVIDE REINFORCING IN SLABS ON GRADE, 1-1/2" FROM TOP OF SLAB:
8" SLABS #4@12" O.C. EA WAY
6" SLABS #4@12" O.C. EA WAY
6" SLAB @ ARMS ROOM #4@ 9" O.C. EA WAY
4" SLABS 6x6 - W2.1x2.1 WWF
20. WHERE SCHEDULES BARS ARE NOT PRESENT, PROVIDE CONTINUOUS #5 TOP AND BOTTOM
BARS TO SUPPORT STIRRUPS AS REQUIRED FOR THE LENGTH OF THE STIRRUP SPACING IN
ALL BEAMS.
21. WALL FOOTING REINFORCING SHALL BE CONTINUOUS THROUGH ADJACENT COLUMN
FOOTINGS.
22. BAR SUPPORTS FOR CONCRETE EXPOSED TO VIEW SHALL HAVE PLASTIC COATED LEGS OR
BE HOT DIP GALVANIZED AFTER FABRICATION.
23. MECHANICAL AND ELECTRICAL CONDUIT SHALL BE PLACED BELOW SLABS ON GRADE.
CONDUIT IN ELEVATED SLABS AND SLABS ON METAL DECK SHALL RUN UNDER TOP LAYER
OF SLAB REINFORCING. PROVIDE A MINIMUM OF 1-1/2" CLEAR BETWEEN CONDUITS AND
BETWEEN REINFORCING AND ADJACENT CONDUITS PARALLEL TO REINFORCING. IF
MAXIMUM SIZE OF CONDUIT EXCEEDS ONE THIRD OF THE SLAB DEPTH, ADDITIONAL
FRAMING OR REINFORCING MAY BE NECESSARY AT ENGINEER'S DIRECTION.
24. THE PLACEMENT OF CONDUITS IN CONCRETE SLAB ON GRADE SHALL ADHERE TO THE
FOLLOWING:
A. OUTSIDE DIAMETER OF CONDUITS SHALL BE 1" OR LESS WHERE EMBEDDED IN
SLABS AND JOINTS, AND 1 1/2" OR LESS WHERE EMBEDDED IN BEAMS,
WALLS, OR COLUMNS.
B. BUNCHING OF CONDUITS IS NOT PERMITTED. CONDUITS SHALL BE SPACED
3 DIAMETERS OR GREATER ON CENTER. NO CROSSOVERS ARE PERMITTED IN
SLABS.
C. LONGITUDINAL PLACEMENT OF CONDUITS IN INDIVIDUAL JOISTS AND BEAMS
SHALL BE LIMITED TO ONE CONDUIT PER JOIST AND THREE CONDUITS PER BEAM.
D. MINIMUM CONCRETE COVER ON CONDUITS SHALL BE 1 1/2".
E. ALUMINUM CONDUITS, PIPES, OR SLEEVES ARE NOT PERMITTED.
25. HEADED SHEAR STUDS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A108, GRADES 1010, 1015, 1017, OR 1020. STUDS SHALL BE AUTOMATICALLY END WELDED IN THE FIELD IN
ACCORDANCE WITH EM 385-1-1 PARAGRAPH 27 F.14.
26. EMBED PLATES MUST BE SET IN THE FORM BEFORE POURING CONCRETE, NOT PLACED INTO
TOP OF WET CONCRETE. THE CONTRACTOR SHALL CONTACT THE STRUCTURAL ENGINEER
FOR CORRECTIVE DETAILS FOR ANY EMBED PLATES LEFT OUT OF CONCRETE POURS.
27. FOR SLABS ON GRADE, SLAB AND GRADE BEAM REINFORCING SHALL BE HELD IN PLACE PER THE
REQUIREMENTS OF SPECIFICATION SECTION 03 20 01.
28. REBAR SHALL NOT BE HEATED WITH A TORCH IN THE FIELD.
29. CONCRETE FINISH:
A. FLOOR SLAB - HARD TROWELED FINISH
B. PAVING SLABS SIDEWALKS - FLOAT BROOM TYPICAL UNLESS ARCHITECTURAL
FINISHES ARE CALLED FOR
C. REFER TO SPECIFICATIONS FOR FINISHING DETAILS FOR EACH AREA
1. ALL EXCAVATION WORK SHALL PROCEED WITH CAUTION TO AVOID DAMAGE TO UNKNOWN
UNDERGROUND UTILITIES OR OTHER OBSTRUCTIONS.
2. THE FOUNDATION DESIGN IS BASED UPON THE RECOMMENDATIONS OUTLINED IN THE
SUBSURFACE INVESTIGATION AND GEOTECHNICAL EVALUATION REPORT, PREPARED BY
ATLANTIC TESTING LABORATORIES, LIMITED, DATED 4 DECEMBER 2015.
3. ALL EXCAVATIONS SHALL BE INSPECTED BY A REPRESENTATIVE OF THE GEOTECHNICAL
ENGINEER OR AN ACCEPTED GEOTECHNICAL TESTING AGENCY TO VERIFY THAT PROPER
BEARING MATERIAL EXISTS PRIOR TO PLACING FOUNDATION CONCRETE.
4. SITE WORK WILL REQUIRE THE REMOVAL OF ANY TOPSOIL AND ORGANIC MATERIAL WITHIN THE
FOOTPRINT OF THE PROPOSED BUILDING.
5. THE SUBGRADE FOR SLAB ON GRADES SHALL BE PREPARED TO APPROXIMATELY 1.2 FEET
BELOW THE FINISHED FLOOR ELEVATION. THE SUBGRADE SOILS SHALL BE PROOF COMPACTED
WITH A MINIMUM 10-TON ROLLER AND PROOF ROLLED IN ACCORDANCE WITH THE
SPECIFICATIONS PRIOR TO PLACING NEW FILL. THE SUBGRADE COMPACTION AND PROOF
ROLLING SHALL BE CONDUCTED UNDER THE OBSERVATION OF A GEOTECHNICAL ENGINEER.
6. ANY SUBGRADE MATERIAL NOTED TO WEAVE OR DEFLECT SHALL BE EXCAVATED TO STABLE
MATERIAL AT THE DIRECTION OF THE GEOTECHNICAL ENGINEER, AND SHALL BE REPLACED
WITH COMPACTED GRANULAR FILL. GRANULAR FILL SHALL BE UTILIZED IF REQUIRED TO RAISE
THE SLAB SUBGRADE ELEVATION.
7. FOOTING SUBGRADES SHALL BE PROOF COMPACTED UNDER THE DIRECTION OF A
GEOTECHNICAL ENGINEER UTILIZING A DUAL-DRUM WALK-BEHIND VIBRATORY ROLLER; A
WACKER DPU 6055 VIBRATING PLATE TAMPER; OR EQUIVALENT.
8. THE IN-SITU SILTY SAND SOILS ENCOUNTERED IN THE BORINGS ARE MOISTURE SENSTIVE.
FOOTING SUBGRADES SHALL NOT BE LEFT EXPOSED TO INCLEMENT WEATHER CONDITIONS.
FOOTING SUBGRADES THAT BECOME SATURATED OR UNSTABLE DURING CONSTRUCTION
SHALL BE OVER EXCAVATED SIX (6) INCHES AND A SIX-INCH LAYER OF NYSDOT NUMBER 2
CRUSHED STONE SHALL BE PLACED ON THE SUBGRADE SOILS (AND COMPACTED AS PER
THE SPECIFICATIONS).
9. CONCRETE SLAB-ON-GRADES SHALL BE SUPPORTED ON A MINIMUM OF EIGHT (8) INCHES OF
ENGINEERED STRUCTURAL FILL SUBBASE THAT OVERLIES PROPERLY PREPARED SUBGRADE
SOILS. AREAS TO RECEIVE SLABS-ON-GRADE SHALL BE PROOF ROLLED IN ACCORDANCE WITH
THE SPECIFICATIONS PRIOR TO PLACING CONTROLLED FILL.
10. VAPOR RETARDER SHALL BE PROVIDED BENNEATH SLABS WITH MOISTURE SENSTIVE FLOOR
COVERINGS. THE VAPOR RETARED SHALL BE INSTALLED IN ACCORDANCE WITH CURRENT
ACI 302.1 RECOMMENDATIONS.
11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN ADEQUATE WATER CONTROL AT ALL
TIMES ON SITE. STANDING WATER AND/OR SATURATED UNSTABLE SOIL CONDITIONS WILL NOT
BE TOLERATED IN AREA TO RECEIVE FOUNDATIONS OR UTILITIES.
12. ALL BACKFILLING, PLACEMENT OF FILL, COMPACTION OF IN-SITU SOILS, AND CONCRETE
CONSTRUCTION SHALL BE INSPECTED BY AN INDEPENDENT TESTING LABORATORY, WHICH
CONFORMS TO ASTM E-329, "THE STANDARD PRACTICE FOR USE IN THE EVALUATION OF
TESTING AND INSPECTION AGENCIES AS USED IN CONSTRUCTION."
13. ALL FOUNDATIONS ARE DESIGNED FOR A MAXIMUM ALLOWABLE SOIL BEARING CAPACITY OF
3000 PSF.
14. ALL COLUMN DOWELS AND ANCHOR BOLTS SHALL BE SET BY A TEMPLATE METHOD
PRIOR TO CONCRETE PLACEMENT, UNLESS SPECIFICALLY NOTED TO BE AFTER SET
ANCHORS. ALL ANCHORS SHALL BE ASTM F1554.
1. DESIGN, FABRICATION AND ERECTION OF OPEN WEB STEEL JOISTS MUST CONFORM TO THE STEEL JOIST INSTITUTE (SJI) "STANDARD SPECIFICATIONS AND LOAD TABLES FOR STEEL JOISTS AND JOIST
GIRDERS," (LATEST EDITION).
2. JOIST MANUFACTURER IS TO PROVIDE ALL ANCHORS AND FASTENERS REQUIRED FOR INSTALLATION
OF JOISTS, BRIDGING AND BOTTOM CHORD EXTENSIONS.
3. PROVIDE BRIDGING AND ANCHORAGE IN ACCORDANCE WITH SJI REQUIREMENTS. BRIDGING IN FIRST TWO AND LAST TWO SPACES SHALL BE "X"-TYPE AND ATTACHED TO A STRUCTURAL WALL, STEEL
BEAM, OR JOIST GIRDER.
4. NO LOADS MAY BE APPLIED TO THE JOISTS UNTIL BRIDGING HAS BEEN COMPLETELY INSTALLED AND
THE JOIST ENDS HAVE BEEN SECURED TO THEIR SUPPORTS.
5. STEEL JOISTS ARE TO BE EQUALLY SPACED IN BAYS UNO. DO NOT EXCEED JOIST SPACING INDICATED
ON THE DRAWINGS.
6. BOTTOM CHORD EXTENSIONS TO BE INSTALLED WHERE SHOWN ON THE DRAWINGS. STEEL JOISTS ARE TO BE DESIGNED FOR 5 KIPS OF SHORT TERM AXIAL LOAD ALONG THE EXTENSION. DO NOT FULLY CONNECT EXTENSIONS TO THE SUPPORTING STRUCTURE UNTIL APPLICABLE DEAD LOAD HAS BEEN APPLIED.
7. STEEL JOIST MANUFACTURER IS TO PROVIDE ADDITIONAL BOTTOM CHORD BRIDGING AS REQUIRED FOR
UPLIFT LOADS.
8. HANGERS SUPPORTING MECHANICAL, ELECTRICAL OR OTHER EQUIPMENT ARE TO BE PLACED AT JOIST PANEL POINTS (WELDING NOT PERMITTED) AND APPLIED LOADS ARE TO BE COORDINATED WITH THE STEEL JOIST MANUFACTURER. DO NOT SUSPEND ANY EQUIPMENT FROM BRIDGING OR METAL DECK.
9. STEEL JOIST MANUFACTURER TO VERIFY SIZE, LOCATION, AND WEIGHT OF ALL SUPPORTED MECHANICAL
UNITS AND ASSOCIATED OPENINGS PRIOR TO FABRICATION.
1. LOAD-BEARING MASONRY WALLS, PILASTERS, PIERS, RETAINING WALLS, FOUNDATION WALLS AND
ANY OTHER MASONRY SO DESIGNATED ON DRAWINGS IS CONSIDERED HERE TO BE STRUCTURAL
MASONRY.
2. REQUIRED COMPRESSIVE STRENGTH OF MASONRY UNITS, MORTAR, AND GROUT SHALL BE PER
SPECIFICATION SECTION 04 20 00.
3. CONCRETE MASONRY UNITS (CMU) SHALL OF WEIGHT AND GRADE AS SPECIFIED PER
SPECIFICATION SECTION 04 20 00. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR
UNIT SIZE, FACE, COLOR, JOINING, ETC.
4. REINFORCING:
A. TYPICAL - ASTM A615, GRADE 60
B. ALL REINFORCING TO BE WELDED - ASTM A706
5. REFER TO THE DRAWINGS FOR REINFORCING LAP TYPICAL DETAIL AND SCHEDULE REQUIREMENTS.
WHERE LAP SPLICES ARE NOT SHOWN, LAP 48 BAR DIAMETERS PER ACI 530, UNLESS NOTED ON DWGS.
6. MAXIMUM HEIGHT TO WHICH MASONRY SHALL BE LAID BEFORE GROUTING SHALL BE PER
SPECIFICATION SECTION 04 20 00.
7. GROUTING PROCEDURES FOR "LOW LIFT" AND "HIGH LIFT" GROUTING SHALL BE PER
SPECIFICATION SECTION 04 20 00. PROVIDE CLEANOUT OPENINGS AT THE BOTTOM OF EACH
GROUT LIFT AT EACH CELL TO BE FILLED WITH GROUT WHERE "HIGH LIFT" GROUTING IS TO BE
USED.
8. REINFORCE MASONRY WHERE SHOWN ON STRUCTURAL DRAWINGS. TIE REINFORCING IN POSITION
AND PLACE GROUT AROUND REINFORCING. DO NOT PUSH REINFORCING DOWN INTO PREVIOUSLY
PLACED GROUT FILL. SET BOLTS SIMILARLY.
9. TIE MASONRY WYTHES WITH HORIZONTAL REINFORCING AS INDICATED BY THE DETAILS.
10. PROVIDE VERTICAL BARS, SIZE MATCHING WALL REINFORCING, AT ALL CORNERS, ENDS OF WALLS, EACH SIDE OF CONTROL JOINTS AND EACH SIDE OF WALL OPENINGS PER THE TYPICAL
DETAILS. TIE EACH BAR TO THE FOUNDATION WITH A MATCHING DOWEL. SEE ARCHITECTURAL
DRAWINGS FOR LOCATIONS OF CONTROL JOINTS.
11. ALL CORNERS AND INTERSECTIONS OF STRUCTURAL MASONRY WALLS SHALL BE CONSTRUCTED
BY INTERLOCKING COURSES.
12. ALL LINTELS SHALL HAVE SUFFICIENT BEARING LENGTH ON EACH SIDE OF OPENINGS AS PROVIDED
BY SPECIFICATION SECTION 04 20 00.FOUNDATIONS
CAST-IN-PLACE CONCRETE/REINFORCING STEELGENERAL NOTES
STRUCTURAL DESIGN DATA
INTERNATIONAL BUILDING CODE (IBC 2012)
ROOF & FLOOR LIVE LOADS:
ROOF 20 PSF
OCCUPIABLE ROOF 100 PSF
OFFICES 50 PSF
PARTITION 15 PSF
CORRIDORS AND PUBLIC ROOMS 100 PSF
CLASSROOMS 40 PSF
RESIDENTIAL, PRIVATE ROOMS 40 PSF
OFFICE STORAGE 125 PSF
HEAVY STORAGE 250 PSF
STAIRS 100 PSF
MECHANICAL ROOMS 125 PSF
ARMORY 150 PSF
ASSEMBLY AREAS:
FIXED SEATS 60 PSF
STAGE FLOORS 150 PSF
STEEL JOISTS
STRUCTURAL MASONRY
STRUCTURAL STEEL
THE FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO ALL REQUIREMENTS OF THE CURRENT AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL BUILDINGS", AND "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES", WITH THE FOLLOWING SUPPLEMENTAL REQUIREMENTS:
1. WIDE FLANGE ROLLED STEEL SHAPES SHALL CONFORM TO ASTM A572A OR ASTM A992, Fy=50 KSI, WHILE ALL PLATES, BARS, CHANNELS, AND ANGLES SHALL CONFORM TO ASTM A36, Fy=36 KSI. HOLLOW STRUCTURAL SECTIONS (HSS) SHALL CONFORM TO ASTM A500, GRADE B, Fy=46 KSI FOR SQUARE AND RECTANGULAR SHAPES, AND Fy=42 KSI FOR ROUND SHAPES.
2. GROUT UNDER THE STEEL BEARING SHALL BE NON- METALLIC, NON -SHRINK, NON GAS FORMING, 5,000 PSI
MINIMUM COMPRESSIVE STRENGTH..
3. STRUCTURAL STEEL SHALL BE NEW UNLESS NOTED OTHERWISE, AND SHALL BE MADE FREE OF RUST, SCALE, ETC., AND SHIPPED WITH ONE COAT OF GRAY OXIDE PRIMER (EXCEPT WHERE PORTIONS OF MEMBERS SHALL BE LEFT UNPAINTED, SUCH AS PORTIONS IN CONTACT AND ACTING COMPOSITELY WITH CONCRETE OR PORTIONS RECEIVING SPRAY-APPLIED FIRE PROTECTION MATERIALS). REFER TO SPECIFICATIONS FOR SHOP PAINTING REQUIREMENTS. AFTER ERECTION, EXPOSED STEEL SHALL BE PAINTED PER PROJECT SPECIFICATIONS. ALL
STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED.
4. BEAM SIMPLE SHEAR CONNECTIONS NOT DETAILED ON STRUCTURAL DRAWINGS SHALL BE DESIGNED BY STEEL SUPPLIER FOR LOADS SHOWN ON DRAWINGS OR FOR REACTIONS DETERMINED BY USING THE ALLOWABLE UNIFORM LOAD AS TABULATED IN PART 2 OF THE AISC MANUAL OF STEEL CONSTRUCTION FOR THE SECTION, SPAN AND STRENGTH OF STEEL SPECIFIED. CONNECTIONS SHALL BE MADE WITH 3/4" DIAMETER BOLTS, ASTM A325 TIGHTENED TO A SNUG-TIGHT CONDITION PER AISC REQUIREMENTS.
5. WHERE STEEL MEMBERS ARE WELDED AND NO SIZE IS SPECIFIED, PROVIDE FULL LENGTH FILLET WELDS
BOTH SIDES OF MEMBER. WELD SIZES SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE:
MEMBER THICKNESS (INCHES) WELD SIZE (INCHES)
3/16 3/16 1/4 3/16 5/16 3/16 3/8 1/4 7/16 1/4 1/2 5/16 9/16 3/8 5/8 7/16
6. SPLICING OF STRUCTURAL STEEL MEMBERS IS PROHIBITED WITHOUT PRIOR APPROVAL OF THE ENGINEER AS TO LOCATION AND TYPE OF SPLICE TO BE MADE. ANY MEMBER HAVING A SPLICE NOT SHOWN AND
DETAILED ON SHOP DRAWINGS WILL BE REJECTED.
7. WELDING SHALL CONFORM TO THE CURRENT AWS D1.1 "STRUCTURAL WELDING CODE - STEEL", AND WELDING ELECTRODES SHALL BE E70XX. WELDS SHALL BE MADE ONLY BY CERTIFIED WELDERS AND WELDING OPERATORS WHO HAVE BEEN PREVIOUSLY QUALIFIED BY TESTS AS PRESCRIBED IN THE CURRENT AWS D1.1 "STRUCTURAL WELDING CODE-STEEL". PROOF OF CERTIFICATION SHALL BE SUBMITTED TO THE OWNER FOR
ACCEPTANCE BEFORE ANY WELDING IS PERMITTED TO BEGIN.
8. SEE THE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ALL ITEMS REQUIRED TO BE HOT-DIP GALVANIZED AFTER FABRICATION. ALL EXTERIOR LINTELS AND SHELF ANGLES ARE TO BE HOT DIPPED
GALVANIZED.
9. STRUCTURAL STEEL SHALL BE PUNCHED FOR WOOD BLOCKING, NAILERS, SLIPS, AND TIES IN ACCORDANCE
WITH ARCHITECTURAL/STRUCTURAL DETAILS.
10. ULTRASONIC INSPECTION BY THE TESTING LABORATORY SHALL BE PER SPECIFICATION SECTION 05 05 23.16;
ULTRASONIC INSPECTION IS REQUIRED ON ALL COMPLETE JOINT PENETRATION WELDS.
11. ALL WELDS SHALL RECEIVE NON-DESTRUCTIVE TESTING/INSPECTION. 100% OF THE STRUCTURAL WELDS SHALL BE VISUALLY INSPECTED. 5% OF THE STRUCTURAL WELDS SHALL BE DYE-PENETRATION TESTED. ALL WELD INSPECTIONS/TESTS SHALL BE COMPLETED BY AN INDEPENDENT CERTIFIED WELDING INSPECTOR (CWI).
12. ALL STEEL EXPOSED TO VIEW SHALL BE CLASSIFIED AS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) AS DEFINED BY THE AISC CODE OF STANDARD PRACTICE AND SHALL BE TREATED AS SUCH.
STEEL DECK AND STAIRS
1. ROOF DECK ATTACHMENT PATTERN PER TYPICAL DETAILS, UNO.
2. ALL DECKING SHALL BE SUPPLIED IN LENGTHS SUFFICIENT TO PERMIT THREE-SPAN SUPPORT CONDITIONS
UNLESS SPECIFICALLY DETAILED OTHERWISE.
3. STEEL STAIRS, LANDINGS, AND ALL CONNECTIONS SHALL BE DESIGNED BY THE SUPPLIER PER SPECIFICATION SECTION 05 51 00. ALL STAIR SHOP DRAWINGS SHALL BEAR THE SEAL OF A REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED. CALCULATIONS SHALL BE
SUBMITTED UPON REQUEST.
4. FLOOR DECK SHALL BE 2" 20 GAGE METAL DECKING.
Fy = 33 ksi; I = 0.409 in /ft; S = 0.341 in /ft; I = 0.406 in /ft; S = 0.346 in /ft
5. FLAT ROOF DECK SHALL BE 3" TYPE N 16 GAGE METAL DECKING.
Fy = 33 KSI, I = 1.683 in /ft; S = 0.893 in /ft; I = 1.807 in /ft; S = 0.944 in /ft
6. SLOPED ROOF DECK SHALL BE 1.5" TYPE B 16 GAGE METAL DECKING.
Fy = 33 KSI, I = 0.373 in /ft; S = 0.408 in /ft; I = 0.373 in /ft; S = 0.411 in /ft
SNOW LOAD DESIGN DATA:
GROUND SNOW LOAD (P ) 70 PSF
FLAT-ROOF SNOW LOAD, (P ) 63.7 PSF
SNOW EXPOSURE FACTOR (C ) 1.0
SNOW LOAD IMPORTANCE FACTOR (I ) 1.00
SNOW DRIFT ADDED AS PER APPLICABLE BUILDING CODES
WIND LOAD DESIGN DATA:
BASIC DESIGN WIND SPEED 115 MPH
RISK CATEGORY II
EXPOSURE CATEGORY C
INTERNAL PRESSURE COEFF. (GC ) + 0.18
VELOCITY PRESSURE (q ) 29.93 PSF
COMPONENTS AND CLADDING:
ALL BUILDING COMPONENTS AND CLADDING ENGINEERED BY THE COMPONENT MANUFACTURER
ARE TO DESIGNED BY THE MANUFACTURER'S ENGINEER FOR WIND LOADS DETERMINED PER
THE INTERNATIONAL BUILDING CODE FOR THE BASIC DESIGN WIND SPEED AND EXPOSURE
LISTED ABOVE.
SEISMIC DESIGN DATA:
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR, (I ) 1.00
SITE CLASS D
DESIGN CATEGORY B
SHORT PERIOD SPECTRAL ACCELERATION S = 0.24g ONE SECOND SPECTRAL ACCELERATION S = 0.08g
DESIGN SPECTRAL ACCELERATION PARAMETERS:
SHORT PERIOD PARAMETER S = 0.231
ONE SECOND PARAMETER S = 0.127
ANALYSIS METHOD: EQUIVALENT LATERAL FORCE PROCEDURE
STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE
RESPONSE MODIFICATION COEFFICIENT, R = 3
OVERSTRENGTH FACTOR, = 3
DEFLECTION AMPLIFICATION FACTOR, C = 3
CONCRETE CONSTRUCTION JOINTS
1. CONTRACTOR SHALL PROVIDE NECESSARY CONSTRUCTION JOINTS IN MONOLITHIC CONCRETE POURS SO THAT THE QUALITY OF PLACEMENT AND FINISH MEETS THE REQUIREMENTS OF PLANS AND SPECIFICATIONS.
THE CONTRACTOR SHALL SUBMIT A PLAN SHOWING THE LOCATION OF ALL CONSTRUCTION JOINTS TO THE
STRUCTURAL ENGINEER FOR APPROVAL.
2. THERE SHALL BE NO HORIZONTAL CONSTRUCTION JOINTS IN CONCRETE POURS. ALL VERTICAL CONSTRUCTION JOINTS IN SLABS AND BEAMS SHALL BE MADE WITH BULKHEADS. ADDITIONAL REINFORCING
AT CONSTRUCTION JOINTS SHALL BE AS SPECIFIED BY STRUCTURAL ENGINEER.
SEE TYPICAL CONSTRUCTION JOINT DETAILS.
LIGHT GAUGE STEEL FRAMING GENERAL NOTES
1. DIMENSIONS SHOWN IN THIS PACKAGE ARE FOR DESIGN REFERENCE ONLY. CONTRACT DRAWINGS
SHOULD BE USED IN DETERMINING EXACT DISTANCES AND ALL CONDITIONS SHOULD BE FIELD
VERIFIED BEFORE ERECTION. ALL LIGHT GAUGE METAL FRAMING SHALL BE FABRICATED IN
ACCORDANCE WITH LATEST AISI SPECIFICATIONS.
2. ALL STRUCTURAL CONNECTIONS SHALL BE COMPLETE AS PER THE PLANS AND SPECIFICATIONS AT THE TIME OF INSTALLATION. FAILURE TO PROMPTLY COMPLETE CONNECTIONS MAY COMPROMISE
THE STRUCTURAL INTEGRITY OF THE BUILDING.
3. HEAVIER GAUGES MAY BE SUBSTITUTED. PROVIDE SHOP DRAWINGS INCLUDING SHAPES, GAUGES, SIZES, SPACINGS, LOCATIONS AND CONNECTIONS. THE EXTERIOR WALLS SHALL BE 600S250-68 MINIMUM
(OR APPROVED EQUAL) @ 16" MAXIMUM SPACING FOR THE BLAST LOADING AS NOTED.
4. ALL COLD FORMED SECTIONS TO BE DESIGNED PER LATEST AISI CODE & ALSO PER DESIGN CRITERIA LISTED ON DWG S-001. ALL DRAWINGS TO BE SIGNED & SEALED BY PROFESSIONAL ENGINEER OF THE
STATE WHERE BUILDING IS CONSTRUCTED.
p p n n 4 3 4 3
S
DS
D1 z pi g f e s e
ATFP GLAZING DESIGN PARAMETERS:
LOCATION: PARKING AND ROADWAYS WITHIN A CONTROLLED PERIMETER
BUILDING CATEGORY: PRIMARY GATHERING
LEVEL OF PROTECTION: LOW
CHARGE WEIGHT = II
CONVENTIONAL CONSTRUCTION STANDOFF DISTANCE: 82 FT
(FOR NON-LOAD BEARING METAL STUDS w/ BRICK VENEER)
MINIMUM STANDOFF DISTANCE: 12 FT
PROVIDED STANDOFF DISTANCE: 82 FT
WINDOW AND DOOR FRAMING STRUCTURE SHALL BE DESIGNED FOR BLAST LOADING PER UFC 4-010-01
& ASTM F2248; METAL STUD CONNECTIONS SHALL ALSO BE DESIGNED FOR BLAST LOADING
p p n n 4 3 4 d
W p p n n 4 3 4
BLAST DESIGN DATA
1. THE EQUIVALENT UNIFORM IMPULSE PRESSURE:
Ir = 30.0 PSI-mSEC
2. THE DESIGN EQUIVALENT PEAK PRESSURE: 5.8 PSI
3. THE BLAST PRESSURE INDICATED ABOVE PERTAINS TO THE
DESIGN OF WINDOWS, DOORS AND CURTAIN WALLS AND THE
ASSOCIATED FRAME CONNECTIONS TO MEET MINIMUM DOD
REQUIREMENTS. REFERENCE THE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
13.0
5.8
TIME (mSEC)
P R
ES
S
U R
E (P
SI
INTERNATIONAL BUILDING CODE (IBC 2012)
ROOF & FLOOR DEAD LOADS:
FLAT ROOF 30 PSF
SLOPED ROOF 32 PSF
FIRST FLOOR 33 PSF
SECOND FLOOR 100 PSF
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
W
2D S-
-R
-0
1/27/2017 3:07:01 PM
S:\Projects\Ft_Drum\NCO Academy\Con_Docs\BIM_Models\Structural\NCOA-STRUCT.rvt
S-001
ST
R
U C
TU
R
AL
G
EN
ER
AL
N
O
TE
S
N C
O A
C A D
EM
Y
C O
M
PL
E X
AM
P
AM
P
C he ck er
O C
T
, 2
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
Am en dm en t 6
-J
AN
-1
K KIP(S)
KB KNEE BRACE
KCF KIPS PER CUBIC FEET
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
L LENGTH
LB POUND
ld DEVELOPMENT LENGTH
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LP LOW POINT
LW LIGHT WEIGHT
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MCJ MASONRY CONTROL JOINT
MECH MECHANICAL(S)
M/E/P MECHANICAL, ELECTRICAL, & PLUMBING
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MP MASONRY PIER
NF NEAR FACE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP HAND OPPOSITE HAND
PERM PERMANENT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVMT PAVEMENT
RAD RADIUS OR RADII
RE: REFER TO
REF REFERENCE
REINF REINFORCEMENT
REQD REQUIRED
REV REVISION OR REVISE
RTU ROOF TOP UNIT
SC SLIP CRITICAL
SDI STEEL DECK INSTITUTE
SECT SECTION
SHT SHEET
SIM SIMILAR
SL SLOPE(D) OR SLOPING
SLV SLEEVE
SOG SLAB ON GRADE
SP SPACE(S)
SPA SPACES OR SPACING
SPEC SPECIFICATIONS
SS STAINLESS STEEL
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUCT STRUCTURAL
T THICKNESS
T&B TOP & BOTTOM
T&S TEMPERATURE & SHRINKAGE
T/ TOP OF
TEMP TEMPORARY
THD THREAD(ED)
THK THICKNESS
TRANS TRANSVERSE
TSF TONS PER SQUARE FEET
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
W WIDTH
W/ WITH
W/O WITHOUT
W/L WIND LOAD
W/P WORKING POINT
WT WEIGHT
WWF WELDED WIRE FABRIC
SYMBOLS
ANGLE
@ AT
CENTERLINE
( )º DEGREE
Ǿ DIAMETER
ELEVATION
= EQUAL
()' FOOT OR FEET
()" INCH OR INCHES
# NUMBEER
//() PARALLEL
% PERCENT
PLATE
S() AMERICAN STANDARD SHAPE
L() ANGLE
C() CHANNEL
L()L DOUBLE ANGLE
HSS() HOLLOW STRUCTURAL SECTION
MC() MISCELLANEOUS CHANNEL
WT() STRUCTURAL TEE
W() WIDE FLANGE
K() OPEN WEB STEEL JOIST
LH() LONGSPAN OPEN WEB STEEL JOIST
ABBREVIATIONS
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
APPROX APPROXIMATE
ARCH ARCHITECT OR ARCHITECTURAL(S)
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
BPL BASE PLATE OR BEARING PLATE
B/ BOTTOM OF
BF BOTH FACES
BLDG BUILDING
BLK BLOCK
BM BEAM
BRG BEARING
BS BOTH SIDES
BT BENT
BTWN BETWEEN
CHAM CHAMFER
CIP CAST IN PLACE
CJ CONTROL JOINT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CRSI CONCRETE REINFORCING STEEL INSTITUTE
db BAR DIAMETER
DBL DOUBLE
DET DETAIL
DEPR DEPRESSION/DEPRESSED
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DWG DRAWING
DWL DOWEL
EA EACH
EF EACH FACE
EL ELEVATION
ELEC ELECTRICAL
EMBED EMBED(ED)(MENT)
ENGR ENGINEER
EOS EDGE OF SLAB
EOW EDGE OF WALL
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE(D)
EW EACH WAY
EXC EXCAVATE OR EXCAVATION
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FF FAR FACE
FIN FINISHED
FL FLOOR
FS FS
FTG FOOTING
GA GAGE OR GAUGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
HORIZ HORIZONTAL
HP HIGH POINT
HT HEIGHT
ID INSIDE DIAMETER
INCL INCLUDE(D)(ING), INCLUSIVE
INFO INFORMATION
INT INTERIOR
ISO JT ISOLATION JOINT
JST JOIST
JT JOINT
PL
BAR DESIGNATION
BAR SPACING
CENTER TO CENTER
LIGHT WEIGHT CONCRETE (110 lb/ft )2.5ELEVATED FLOOR/ROOF SLABS
F'c = 4.0 ksi F'c = 3.0 ksi
4db
7. FOR LIGHTWEIGHT CONCRETE: MULTIPLY THE ABOVE LAP SPLICE VALUES BY 1.3 UNO.
6. CATEGORY FOR BARS SPACED LESS THAN 4d, ON CENTER CORRESPONDS TO CATEGORY 1 IN THE CRSI HANDBOOK WHEREAS FOR BARS SPACED 4d OR MORE ON CENTER CORRESPONDS TO CRSI CATEGORY 5.
1. YIELD STRENGTH OF REINFORCEMENT, (Fy) IS 60 ksi (LAP SPLICE LENGTH IS IN INCHES).
2. CONCRETE IS NORMAL WEIGHT (150 lb/ft ).
3. TOP BAR INDICATES HORIZONTAL REINFORCEMENT WHICH IS PLACED ABOVE 12 INCHES OR MORE OF FRESH CONCRETE.
4. UNLESS NOTED OTHERWISE COLUMNS & PIERS UTILIZE TENSION LAP SPLICES.
5. STRAIGHT DEVELOPMENT LENGTH OF AN UNLAPPED BAR IS EQUAL TO VALUE FROM TABLE DIVIDED BY 1.3.
OTHER BARS
MORE
4db
CENTER TO CENTER
BAR SPACING
BAR DESIGNATION
NOTES:
TOP BARS
4db
THAN
LESS
4db
THAN
LESS
MORE
4db
OR
OR
4db
TOP BARS
4db
THAN
LESS
MORE
OR
4db
OTHER BARS
MORE
OR
4db
4db
THAN
LESS
HOOK DEVELOPMENT LENGTH
PROVIDE STANDARD BAR CHAIRS AND SPACERS AS REQUIRED
TO MAINTAIN CONCRETE PROTECTION SPECIFIED.
HOOK DEVELOPMENT LENGTH IS VALID FOR
180° HOOKS ALSO.
REDUCTION FOR EXCESS REINFORCEMENT
IS NOT TAKEN.
TIE OR STIRRUP REQUIREMENTS OF ACI
SECT. 12.5.3.2 ARE ASSUMED NOT TO BE
MET.
NOTES:
CONCRETE IS NORMAL WEIGHT CONCRETE.
BAR YIELD STRENGTH, Fy = 60 ksi
SIDE COVER REQUIREMENTS OF ACI SECT.
12.5.3.2 ARE ASSUMED NOT TO BE MET.
3.
5.
4.
2.
1.
MINIMUM CONCRETE COVER PROTECTION FOR REINFORCEMENT
BARS SHALL BE AS FOLLOWS: (RE: ACI 318)
DIMENSIONS FOR BAR PLACEMENT GIVEN IN SECTIONS AND
DETAILS SHALL SUPERSEDE MINIMUM COVER REQUIREMENTS
GIVEN HERE.
RETAINING WALLS (NO SURFACES SHALL BE EARTH FORMED)
SLABS-ON-GRADE (NO EXPOSURE TO WEATHER) FROM TOP
#5 BAR & SMALLER
#6 THRU #11 BAR
1. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (150 lb/ft ) UNO.
COMPRESSIVE
STRENGTH @
COLUMNS / PIERS
SLABS-ON-GRADE (EXPOSURE TO WEATHER) FROM TOP
EARTH SIDE AND FRONT SIDE (EXPOSED TO WEATHER):
BOTTOM
TOP
GRADE BEAMS OR SLAB TURNED DOWN EDGES:
#5 BAR AND SMALLER
#6 THRU #11 BAR
SIDES (EARTH FORMED)
SIDES (BOARD FORMED)
FOOTINGS (EARTH FORMED)
ALL OTHER CONCRETE
SLAB-ON-GRADE
ALL FOOTINGS U.N.O.
NOTES:
STRUCTURAL
ELEMENT
4.5
4.0
28 DAYS
(ksi) 4.5
CONCRETE
f'c
#9
1.5 INCHES
2.5 INCHES
1.5 INCHES
2.5 INCHES
2.0 INCHES
3.0 INCHES
3.0 INCHES
3.0 INCHES
1.5 INCHES
2.0 INCHES
3.0 INCHES
#10 #11
REMARKS
#8 #7
#5 #6
#4
BAR
SIZE
#3
3 ksi
4.0 ksi
Ldh (INCHES)
F'c
F'c
RECTANGULAR TUBE STEEL
CONNECTIONS, PLATES &
STUDS/TRUSS MEMBERS
LIGHT GAGE METAL
ANCHOR RODS
PIPES
ROUND TUBE STEEL
ALL OTHERS
BRACING
BEAMS & COLUMNS (UNO)
ELEMENT
STRUCTURAL
ASTM A36M36
ASTM A653M
ASTM A500 GRADE B
ASTM A36M
ASTM A53 GRADE B
YIELD STRENGTH
(ksi)
Fy
ASTM A500 GRADE B
ASTM A992M
ASTM A36M
REMARKS
4.5
5.5
5.0
3.0
4.0
3.5
2.5
2.0
1.5#3
#9
#10
#11
#6
#8
#7
#4
#5
#3
#9
#10
#11
#6
#8
#7
#4
#5
8. FOR EPOXY COATED REINFORCEMENT: MULTIPLY THE ABOVE LAP SPLICE VALUES BY 1.5.
MINIMUM LAP SPLICES OF REINFORCING BARS IN TENSION (PER ACI 318)
CONCRETE COVER SCHEDULE
CONCRETE MATERIALS SCHEDULE
TENSION PER (ACI 318)
STANDARD HOOKS IN
STEEL MATERIALS SCHEDULE
LENGTH, Ldh
HOOK DEVELOPMENT
H O
O K
EX
TE
N
SI
O N
PE
R
A C
E
CHANNELS, C-SHAPE STEEL 36 ASTM A992M
6.
F
CONCRETE LOOR FLATNESS (F ) AND LEVELNESS (F )
APPLICATION LOCATIONS
CONCRETE FLOOR FINISH NOTES:
1. REFER TO ACI 302.1R FOR GUIDELINES ON PLACING AND FINISHING OF CONCRETE
FLOORS SLAB CONSTRUCTION FOR THE F-NUMBER SYSTEM.
2. ASTM E 1155 IS THE BASIS OF THE STANDARD TEST METHOD FOR THE F-NUMBER
SYSTEM.
F L
SPECIFIED OVERALL VALUE MINIMUM LOCAL VALUE
F FL FF FL
MECHANICAL/UTILITY ROOMS
OFFICES, CLASSROOMS,
BARRACKS, ARMS ROOM, & ALL
ROOMS RECEIVING FLOOR
FINISHES (CARPET, TILES, ETC.)
TRAINING ROOM
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
W
2D S-
-R
-0
1/27/2017 3:07:02 PM
S:\Projects\Ft_Drum\NCO Academy\Con_Docs\BIM_Models\Structural\NCOA-STRUCT.rvt
S-002
ST
R
U C
TU
R
AL
S
Y M
BO
L S
S C
H
ED
U
LE
S
N C
O A
C A D
EM
Y
C O
M
PL
E X
AM
P
AM
P
C he ck er
O C
T
, 2
STRUCTURAL FOOTING SCHEDULE
TYPE WIDTH LENGTH THICKNESS REINFORCEMENT
TOTAL
QUANTITY Comments
F1 6' - 0" 6' - 0" 1' - 6" (6) #6 EW T&B 3
F2 8' - 0" 8' - 0" 1' - 6" (8) #6 EW T&B 4
F3 9' - 0" 9' - 0" 1' - 6" (8) #6 EW T&B 6
F4 11' - 0" 11' - 0" 1' - 6" (12) #6 EW T&B 20
F5 12' - 6" 12' - 6" 2' - 0" (15) #6 EW T&B 23
F6 12' - 0" 16' - 0" 1' - 6" (12) #6 LONG T&B /
(18) #6 SHORT T&B
1 (2) PIERS
MF1 3' - 0" 3' - 0" 1' - 0" (4) #6 EW T&B 6
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
Am en dm en t 6
-J
AN
-1
65432
H
G
F
E
B
C
D
F.1
A
E.1
11' - 11" 30' - 8" 32' - 3" 30' - 2" 32' - 3"
6'
8"
5'
0"
2'
8"
5'
2"
5'
0"
S-201 1
C O
L.
L
IN
E
S-204
3 COL. LINE C
S-208
2 COL. LINE H
S-205
1 COL. LINE D
S-207
COL. LINE F.1,
PART A
S-206
COL. LINE E.1,
PART A
S-201 3
C O
L.
L
IN
E
S-201 4
C O
L.
L
IN
E
SLAB ON GRADE
F.F. = O.O FEET
S-502
S-502
CJ
C J
CJ
CJ
CJ
C J
C J
C J
CJ
CJ
CJ
CJ
C J
C J
C J
C J
M
AT
C H
LI
N
E
S-
1B
DEPRESSED SLAB
FOR ENTRANCE MAT
S-210 1
W
ES
T
FR
AM
IN
G
EL
EV
AT
IO
N
S-511
TRENCH DRAIN
S-504
S-201 2
C O
L.
L
IN
E
S-504
S-504
S-514
S-514
S-514
S-502
F2 F4
F4F4
F4
F2
F4
F4
F4
F4
F4
F5
F5F5 F5
F5
F5F5F5
F5
F5
F5
F5
F3
F5
6'
8"
5'
0"
2'
8"
5'
2"
5'
0"
S-502
T/FTG
TYP INT FTG
T/FTG
TYP EXT FTG
-5' - 0"
-2' - 0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
W
2D S-
-R
-0
1/27/2017 3:07:03 PM
S:\Projects\Ft_Drum\NCO Academy\Con_Docs\BIM_Models\Structural\NCOA-STRUCT.rvt
S-101A
FO
U
N D
AT
IO
N P
LA
N
PA
R T
A
N C
O A
C A D
EM
Y
C O
M
PL
E X
AM
P
AM
P
C he ck er
O C
T
, 2
1/8" = 1'-0"1 01_FOUNDATION PLAN - PART A
NOTES:
1. SEE SHEET S-001 FOR GENERAL NOTES AND DESIGN CRITERIA.
2. COORINDATE DIMENSIONS, WALL OPENINGS, ELEVATIONS, SECTIONS, AND DETAILS WITH ARCHITECTURAL DRAWINGS.
3. THE FINISHED FLOOR ELEVATION IS 0' - 0" U.N.O.
4. THE SLAB SHALL BE A 6-INCH THICK REINFORCED CONCRETE SLAB-ON-GRADE w/ #4 @ 12" O.C. EACH WAY.
5. THE ARMS ROOM SHALL BE PROVIDED A 6-INCH THICK REINFORCED CONCRETE SLAB-ON-GRADE w/ #4 @ 9" O.C. EACH WAY.
5. ALL WALLS AND COLUMNS SHALL BE SUPPORTED ON REINFORCED CONCRETE SPREAD FOUNDATIONS.
6. REFER TO MECHANICAL DWGS FOR EXTENT, LAYOUT, AND LOCATION OF RADIANT FLOOR HEATING IN THIS PORTION.
KEYPLAN
PART C
PART A PART B
0' 4' 8' 16' 32'
STRUCTURAL FOOTING SCHEDULE
TYPE WIDTH LENGTH THICKNESS REINFORCEMENT
TOTAL
QUANTITY Comments
F1 6' - 0" 6' - 0" 1' - 6" (6) #6 EW T&B 3
F2 8' - 0" 8' - 0" 1' - 6" (8) #6 EW T&B 4
F3 9' - 0" 9' - 0" 1' - 6" (8) #6 EW T&B 6
F4 11' - 0" 11' - 0" 1' - 6" (12) #6 EW T&B 20
F5 12' - 6" 12' - 6" 2' - 0" (15) #6 EW T&B 23
F6 12' - 0" 16' - 0" 1' - 6" (12) #6 LONG T&B /
(18) #6 SHORT T&B
1 (2) PIERS
MF1 3' - 0" 3' - 0" 1' - 0" (4) #6 EW T&B 6
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
Am en dm en t 6
-J
AN
-1
131211109876
G
F
E
B
C
D
F.1
147.1
A
E.1
13' - 0" 18' - 7" 13' - 8" 23' - 4" 13' - 6" 26' - 0" 31' - 2" 27' - 8" 12' - 10"
S-502
S-204
2 COL. LINE B
S-203 3
C O
L.
L
IN
E
S-208
2 COL. LINE H
S-205
1 COL. LINE D
S-204
3 COL. LINE C
S-203 3
C O
L.
L
IN
E
S-206
COL. LINE E.1,
PART B
S-207
COL. LINE F.1,
PART B
S-203 2
C O
L.
L
IN
E
S-203 4
C O
L.
L
IN
E
S-205
2 COL. LINE E
S-202 4
C O
L.
L
IN
E
S-201 4
C O
L.
L
IN
E
S-202 1
C O
L.
L
IN
E
S-202 2
C O
L.
L
IN
E
7.
S-203 1
C O
L.
L
IN
E
S-208
1 COL. LINE G
S-502
SLAB ON GRADE
F.F. = O.O FEET
SLOPED SLAB ON GRADE
CONC BASES FOR
LOCKERS (TYP)
S-502
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
S-501
M
AT
C H
LI
N
E
S-
1A
DEPRESSED SLAB
FOR ENTRANCE MAT
DEPRESSED SLAB
FOR SHOWERS
S-209
SOUTH
FRAMING
ELEVATION
S-209
1 NORTH
FRAMING
ELEVATION
S-2102
EA
ST
FR
AM
IN
G
EL
EV
AT
IO
N
S-511
SLOPED SLAB BEGINS
SLOPED
SLAB
ENDS
4.76° [No Slope]
S-502
S-502
S-512
CONC EQUIP. PADS
S-504
S-504
S-204
1 COL. LINE A
S-202 3
C O
L.
L
IN
E
S-514
M-1 M-2
M-3
S-518
M-4
S-518
M-5 M-6
M-7
M-8
S-503
F2 F2
F4
F4
F4
F4
F4
F4 F4
F4
F4
F4
F4
F4 F4
F4 F5
F5
F5
F5 F5
F5F5
F5 F5
F5
F3
F3
F3
F3
F3
F5
F5
F1 F1 6'
8"
5'
0"
2'
8"
5'
2" 5'
0"
MF1
MF1
MF1 MF1
MF1
-5' - 10"
T/FTG T/FTG
TYP EXT FTG
T/FTG
TYP INT FTG
-2' - 0"
-5' - 6"
T/FTG
-5' - 0"
-5' - 0"
T/FTG
T/FTG
TYP EXT FTG
-5' - 0"
T/FTG
TYP EXT FTG
S-514
S-503
F
S-515
-5' - 0"
T/FTG
TYP EXT FTG
S-503
F6
-5' - 10"
-5' - 0"
T/FTG
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
W
2D S-
-R
-0
1/27/2017 3:07:04 PM
S:\Projects\Ft_Drum\NCO Academy\Con_Docs\BIM_Models\Structural\NCOA-STRUCT.rvt
S-101B
FO
U
N D
AT
IO
N P
LA
N
PA
R T
B
N C
O A
C A D
EM
Y
C O
M
PL
E X
AM
P
AM
P
C he ck er
O C
T
, 2
1/8" = 1'-0"1 01_FOUNDATION PLAN - PART B
KEYPLAN
PART C
PART A PART B
0' 4' 8' 16' 32'
NOTES:
1. SEE SHEET S-001 FOR GENERAL NOTES AND DESIGN CRITERIA.
2. COORINDATE DIMENSIONS, WALL OPENINGS, ELEVATIONS, SECTIONS, AND DETAILS WITH ARCHITECTURAL DRAWINGS.
3. THE FINISHED FLOOR ELEVATION IS 0' - 0" U.N.O.
4. THE SLAB SHALL BE A 6-INCH THICK REINFORCED CONCRETE SLAB-ON-GRADE w/ #4 @ 12" O.C. EACH WAY U.N.O.
5. ALL WALLS AND COLUMNS SHALL BE SUPPORTED ON REINFORCED CONCRETE SPREAD FOUNDATIONS.
STRUCTURAL FOOTING SCHEDULE
TYPE WIDTH LENGTH THICKNESS REINFORCEMENT
TOTAL
QUANTITY Comments
F1 6' - 0" 6' - 0" 1' - 6" (6) #6 EW T&B 3
F2 8' - 0" 8' - 0" 1' - 6" (8) #6 EW T&B 4
F3 9' - 0" 9' - 0" 1' - 6" (8) #6 EW T&B 6
F4 11' - 0" 11' - 0" 1' - 6" (12) #6 EW T&B 20
F5 12' - 6" 12' - 6" 2' - 0" (15) #6 EW T&B 23
F6 12' - 0" 16' - 0" 1' - 6" (12) #6 LONG T&B /
(18) #6 SHORT T&B
1 (2) PIERS
MF1 3' - 0" 3' - 0" 1' - 0" (4) #6 EW T&B 6
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
Am en dm en t 6
-J
AN
-1
G
F
E
B
C
D
F.1
147.1
A
E.1
S-204
2 COL. LINE B
S-203 3
C O
L.
L
IN
E
S-204
3 COL. LINE C
S-205
1 COL. LINE D
S-208
2 COL. LINE H
13' - 0" 18' - 7" 13' - 8" 23' - 4" 13' - 6" 26' - 0" 31' - 2" 27' - 8" 12' - 10"
6'
8"
5'
0"
2'
8"
5'
2"
5'
0"
S-206
COL. LINE E.1,
PART B
S-207
COL. LINE F.1,
PART B
S-203 2
C O
L.
L
IN
E
S-203 4
C O
L.
L
IN
E
S-205
2 COL. LINE E
S-202 4
C O
L.
L
IN
E
S-201 4
C O
L.
L
IN
E
S-202 1
C O
L.
L
IN
E
S-202 2
C O
L.
L
IN
E
7.
S-203 1
C O
L.
L
IN
E
S-208
1 COL. LINE G
S-511
W
X2
W14X22
W
X2
W14X22
W
X3
W
X3
W27X129
W
X3
W24X84
W
X3
W24X103
W
X3
W24X68W24X68
W27X84 W27X84
W
X2
W
X2
W
X4
W
X6
W16X40 W27X129 W16X100 W16X40 W27X94
W
X2
W
X2
W16X100
W
X4
W14X30W16X67W24X103W14X30
W
X6
W
X4
W
X3
W
X6
W16X40
W
X3
W
X6
W16X67 W24X55
W24X68
W
X6
W
X4
W24X68W24X84
W24X55
W
X2
W
X3
W24X55
W
X3
W
X8
W24X68
W
X2
W24X84
W24X68
W27X129
W
X3
W
X3
LH
W
X6
W24X68W24X55
SP 54G 14N 13K
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X3
W
X3
W
X3
W
X3
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X2
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X2
W
X2
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X3
W
X2
W
X2
W
X2
W 1 4
X2
W
X2
W
X4
W
X4
W
X4
W
X4
W
X3
W
X3
W
X3
W
X3
W
X2
W
X2
W
X2
W
X2
LH
LH
LH
LH
LH
LH
LH
LH
LH
W16X40
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
W
X2
W24X68 W27X84
W
X2
W
X2
W
X2
W
X4
W
X3
W
X2
W
X2
LH
LH
LH
LH
LH
LH
LH
LH
D
D
R
SL
O
PE
D
R O
O F
FLAT ROOF
F
F
F
F
F
(-9' - 5 1/2")
(-0' - 8")$
S-506
(-9' - 5 1/2")
(-0' - 5")
(-0' - 5")
M
AT
C H
LI
N
E
S-
2A
OPEN TO
BELOW
(2 2)
(2 2)
(2 2)
(2 2)
(2 2)
(2 2)
(2 2)
(2 2)
(2 2)
(2
2) (4
8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(5 4)
(4
4) (7
2)
(6 4)
(3 2)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(3 6)
(3 2)
(1 8)
(1 8)
(1 8)
(1 8)
(1 8)
(1 8)
(1 8)
(1 8)
(1 8)
(1 8)
(1 8)
(4 8)
(6
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(4 8)
(5 8)
(4 8)
(4 8)
(5 8)
(4 8)
(4 8)
(4 8)
(4 8)
(1 7)
(1 9)
(3 2)
(3 2)
(1 7)
(1 9)
(1 7)
(1 9)
(1 7)
(1 9)
(1 7)
(1 9)
(1 7)
(1 9)
(3 4)
(3 8)
(1 9)
(1 9)
(1 9)
(1 9)
(1 9)
(1 9)
(1 9)
(1 9)
(1 9)
(1 9)
(2 0)
(2 0)
(2
0) (2
0)
(2 0)
(2 0)
(2 0)
(2 0)
(2 0)
(2 0)
(48) (62)(50)
(82) (112)(84)
(84) (82)
(103) (36)
(9
(9
(48)
(54)
(48)(48)
(90)(80)(84)
(50)
(54)
(33)
(60)
(38)(48)
(90)(52)
(30)(50)
(84)
S-209
SOUTH
FRAMING
ELEVATION
S-209
1 NORTH
FRAMING
ELEVATION
S-2102
EA
ST
FR
AM
IN
G
EL
EV
AT
IO
N
(3' - 4")
S-204
1 COL. LINE A
(0
(-8
0"
(0
(-8
0"
DENOTES BEAM-TO-COLUMN
MOMENT CONNECTIONS
(REFER TO FRAMING ELEVATIONS
FOR DESIGN LOADING)
(9
W
X2
W
X4
W
X3
(80)
(2 0)
(9
S-202 3
C O
L.
L
IN
E
S-503
EQUIPMENT PAD
(-2' - 0")
(-2
") (-2
(-9
2'
8"
S-508
S-508
S-516
S-516
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
W
2D S-
-R
-0
1/27/2017 3:07:05 PM
S:\Projects\Ft_Drum\NCO Academy\Con_Docs\BIM_Models\Structural\NCOA-STRUCT.rvt
S-102B
SE
C
O N
D F
L R P
LA
N
PA
R T
B
N C
O A
C A D
EM
Y
C O
M
PL
E X
AM
P
AM
P
C he ck er
O C
T
, 2
1/8" = 1'-0"1 02_2nd FLR PLAN - PART B
KEYPLAN
PART C
PART A PART B
0' 4' 8' 16' 32'
NOTES:
1. SEE SHEET S-001 FOR GENERAL NOTES AND DESIGN CRITERIA
2. COORINDATE DIMENSIONS, WALL OPENINGS, ELEVATIONS, SECTIONS, AND DETAILS WITH ARCHITECTURAL DRAWINGS.
3. T/STEEL ELEVATION = 15' - 7" FOR THE SECOND FLOOR STRUCTURAL MEMBERS, & T/SLAB ELEVATION = 16' - 0".
4. STRUCTURAL MEMBERS DENOTED WITH A " " SYMBOL ARE ASSOCIATED WITH THE LOWER ROOF FOR THE AUDITORIUM.
THE T/STEEL ELEVATION FOR THE AUDITORIUM ROOF = 20' - 4"
5. INDICATES THE SPAN DIRECTION FOR THE 3" METAL ROOF DECK FOR THE FLAT ROOF SECTIONS. THE ROOF SHALL CONSIST OF 3" METAL ROOF DECK WITH RIGID INSULATION AND ROOFING AS PER ARCHITECTURAL DRAWINGS AND DETAILS.
6. INDICATES THE SPAN DIRECTION FOR THE 1-1/2" METAL ROOF DECK FOR THE SLOPED ROOF SECTIONS. THE ROOF SHALL CONSIST OF 1-1/2" METAL ROOF DECK WITH RIGID INSULATION AND ROOFING AS PER ARCHITECTURAL DWGS AND DETAILS.
R
7. INDICATES ROOF SLOPE DIRECTION. REFER TO ARCHITECTURAL DRAWINGS FOR FINAL ROOF SLOPE AND PROFILE.
8. INDICATES THE SPAN DIRECTION FOR THE 5" COMPOSITE FLOOR SLAB SYSTEM WITH 3" THICK LIGHTWEIGHT CONCRETE OVER A 20-GAGE 2" METAL DECK REINFORCED WITH 6x6 - W1.4xW1.4 WELDED WIRE MESH.
9. ALL SHEAR STUDS FOR THE COMPOSITE FLOOR SYSTEM SHALL BE 3/4" DIAMETER STUDS WITH A MINIMUM LENGTH OF 3-1/2 INCHES.
10. THE MINIMUM NUMBER OF SHEAR STUDS ON EACH BEAM IS IDENTIFIED AS (#) ON EACH COMPOSITE BEAM AND SHALL BE AT UNIFORM
SPACING ACROSS THE BEAM U.N.O.
11. THE MAXIMUM SHEAR STUD SPACING IS 24 INCHES O.C. FOR ALL COMPOSITE BEAMS.
12. ELEVATIONS NOTED ON A BEAM AS (#' - #") INDICATES THE CHANGE IN ELEVATION FROM THE NOTED T/STEEL ELEVATION.
13. BEAMS AND GIRDERS SUPPORTING OPEN-WEB ROOF JOISTS HAVE A T/STL ELEVATION OFFSET TO ACCOUNT FOR JOIST SEAT DEPTH.
THIS OFFSET SHALL BE COORDINATED WITH THE ACTUAL JOIST SEAT DEPTH AND THE STEEL FABRICATORS.
F
SLOPE
D
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
Am en dm en t 6
-J
AN
-1
65432
G
F
E
B
C
D
F.1
A
E.1
S-201 1
C O
L.
L
IN
E
S-204
3 COL. LINE C
S-208
2 COL. LINE H
S-205
1 COL. LINE D
S-207
COL. LINE F.1,
PART A
S-206
COL. LINE E.1,
PART A
11' - 11" 30' - 8" 32' - 3" 30' - 2" 32' - 3"
6'
8"
5'
0"
2'
8"
5'
2"
5'
0"
S-201 3
C O
L.
L
IN
E
S-201 4
C O
L.
L
IN
E
W27X84 W27X84 W27X84 W24X68
W
X6
W
X6
W27X94W27X84W27X94W27X84
W
X6
W
X4
W27X84
LH
W
X3
32G 9N 12K
LH
W
X4
W
X6
W24X68
W
X3
W24X84 W24X84 W24X68
LH
LH
W
X6
W
X4
W
X4
W
X6
R
R
R
R
R
(-0' - 6") (-0' - 6") (-0' - 6")
(-1' - 6")
(-0' - 6") (-0' - 6") (-0' - 6")
(-0' - 6")
(-0' - 6")
(-1' - 6")
(-0' - 6")
M
AT
C H
LI
N
E
S-
3B
S-210 1
W
ES
T
FR
AM
IN
G
EL
EV
AT
IO
N
LOCATION OF BLDG
EXPANSION JOINT
(-1' - 6") (-1' - 6")
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
SL
O
PE
SL
O
PE
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
1 0
LH
LH
LH
LH
(-1' - 8")
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
1 0
SL
O
PE
SL
O
PE
SL
O
PE
LH
LH
LH
LH
LH
LH
LH
SL
O
PE
SL
O
PE
SL
O
PE
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
LH
LH
(-1
(0
(-1
(0
(-1
(0
(-1
(0
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
1 0
SL
O
PE
SL
O
PE
DENOTES BEAM-TO-COLUMN
MOMENT CONNECTIONS
(REFER TO FRAMING ELEVATIONS
FOR DESIGN LOADING)
S-201 2
C O
L.
L
IN
E
(-1
(-1
(-1
(0
(0
(0
W
X3
W
X3
W
X3
SL
O
PE
R
S-510
S-516
Sim
S-508
Sim
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
W
2D S-
-R
-0
1/27/2017 3:07:06 PM
S:\Projects\Ft_Drum\NCO Academy\Con_Docs\BIM_Models\Structural\NCOA-STRUCT.rvt
S-103A
R O
O F
P L
AN
PA
R T
A
N C
O A
C A D
EM
Y
C O
M
PL
E X
AM
P
AM
P
C he ck er
O C
T
, 2
1/8" = 1'-0"1 03_ROOF PLAN - PART A
KEYPLAN
PART C
PART A PART B
0' 4' 8' 16' 32'
NOTES:
1. SEE SHEET S-001 FOR GENERAL NOTES AND DESIGN CRITERIA
2. COORINDATE DIMENSIONS, ROOF OPENINGS, ELEVATIONS, SECTIONS, AND DETAILS WITH ARCHITECTURAL DRAWINGS.
3. T/STEEL ELEVATION = 31' - 7" FOR THE MAIN ROOF LEVEL STRUCTURAL MEMBERS.
4. ELEVATIONS NOTED ON A BEAM AS (#' - #") INDICATES THE CHANGE IN ELEVATION FROM THE NOTED T/STEEL ELEVATION.
5. BEAMS AND GIRDERS SUPPORTING OPEN-WEB ROOF JOISTS HAVE A T/STL ELEVATION OFFSET TO ACCOUNT FOR JOIST SEAT DEPTH.
THIS OFFSET SHALL BE COORDINATED WITH THE ACTUAL JOIST SEAT DEPTH AND THE STEEL FABRICATORS.
6. INDICATES THE SPAN DIRECTION FOR THE 3" METAL ROOF DECK FOR THE ROOF.R
7. INDICATES ROOF SLOPE DIRECTION. REFER TO ARCHITECTURAL DRAWINGS FOR
FINAL ROOF SLOPE AND PROFILE.
8. THE ROOF SHALL CONSIST OF 3" METAL ROOF DECK WITH RIGID INSULATION AND ROOFING
AS PER ARCHITECTURAL DRAWINGS AND DETAILS.
SLOPE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
Am en dm en t 6
-J
AN
-1
G
F
E
B
C
D
F.1
147.1
A
E.1
S-204
2 COL. LINE B
S-203 3
C O
L.
L
IN
E
13' - 0" 18' - 7" 13' - 8" 23' - 4" 13' - 6" 26' - 0" 31' - 2" 27' - 8" 12' - 10"
S-206
COL. LINE E.1,
PART B
S-207
COL. LINE F.1,
PART B
S-203 2
C O
L.
L
IN
E
S-203 4
C O
L.
L
IN
E
S-205
2 COL. LINE E
S-202 4
C O
L.
L
IN
E
S-201 4
C O
L.
L
IN
E
S-202 1
C O
L.
L
IN
E
S-202 2
C O
L.
L
IN
E
7.
S-203 1 C
O L.
L
IN
E
S-208
1 COL. LINE G
6'
8"
5'
0"
2'
8"
5'
2"
5'
0"
W24X68
W
X6
W
X6
W27X94
W27X84 W27X84 W27X129
W
X2
W16X40
W
X3
W
X3
W24X68 W27X84 W27X84
W
X6
W
X4
W27X84W27X84
W
X2
W27X84W16X40W24X68W27X129W16X40
W16X40 W24X68 36G 10N 12K W24X55 32G 9N 12K 28G 8N 12K
LH
LH
LH
W
X3
W
X6
W
X2
W16X40SP 36G 19N 5K
W
X4
32G 9N 12K
LH
32G 9N 12K
LH
W
X4
36G 10N 12K
W
X4
W16X40
W
X3
LH
LH
W
X5
W
X6
W
X6
LH
W24X68
SP 32G 17N 5K
LH
W
X2
R
R
R
R
R
R R
(-0' - 6")
(-0' - 6")
(-1' - 6")
(-0' - 6")
(-1' - 6") (-1' - 6")
(-0' - 6")
(-0' - 6") (-0' - 6")
(-0' - 6")
(-0' - 6") (-0' - 6") (-0' - 6")
(-1' - 6")
(-0' - 6")
(-0' - 6")
(-0' - 6")
(-0' - 6")
(-0' - 6") (-0' - 6")
(-0' - 6")(-0' - 6")(-0' - 6")
M
AT
C H
LI
N
E
S-
3A
S-209
SOUTH
FRAMING
ELEVATION
S-209
1 NORTH
FRAMING
ELEVATION
S-2102
EA
ST
FR
AM
IN
G
EL
EV
AT
IO
N
(-1' - 6")(-1' - 6")(-1' - 6")
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
1 0
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
SL
O
PE
W
X2
LH
LH
LH
SL
O
PE
(-1' - 8") (-1' - 8")
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
1 0
LH
(-1' - 8")
(-1' - 8")
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
1 0
LH
LH
LH
LH
LH
LH
LH
LH
LH
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
LH
LH
LH
W
X3
W
X3
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
R(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(-1
(0
(-1
(-0
/4
(0
(-1
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
SL
O
PE
SL
O
PE
R
LH
LH
LH
LH
LH
LH
LH
LH
LH
(-1
(0
LH
LH
LH
(-1
(0
(-1
(0
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
1 0
LH
LH
LH
LH
LH
LH
LH
LH
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
(-1
(0
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
SL
O
PE
SL
O
PE SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
R
R
W
X2
(-0
/4
(0
(-0
/4
(0
(-0
/4
S-204
1 COL. LINE A
S-512
DENOTES BEAM-TO-COLUMN
MOMENT CONNECTIONS
(REFER TO FRAMING ELEVATIONS
FOR DESIGN LOADING)
W
X2
S-202 3
C O
L.
L
IN
E
(0
(0
(0
(-1
(-1
(-1
W
X3
W
X3
W
X3
R
SL
O
PE
S-510
S-516
Sim
S-508
Sim
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
W
2D S-
-R
-0
1/27/2017 3:07:07 PM
S:\Projects\Ft_Drum\NCO Academy\Con_Docs\BIM_Models\Structural\NCOA-STRUCT.rvt
S-103B
R O
O F
P L
AN
PA
R T
B
N C
O A
C A D
EM
Y
C O
M
PL
E X
AM
P
AM
P
C he ck er
O C
T
, 2
1/8" = 1'-0"1 03_ROOF PLAN - PART B
KEYPLAN
PART C
PART A PART B
0' 4' 8' 16' 32'
NOTES:
1. SEE SHEET S-001 FOR GENERAL NOTES AND DESIGN CRITERIA
2. COORINDATE DIMENSIONS, ROOF OPENINGS, ELEVATIONS, SECTIONS, AND DETAILS WITH ARCHITECTURAL DRAWINGS.
3. T/STEEL ELEVATION = 31' - 7" FOR THE MAIN ROOF LEVEL STRUCTURAL MEMBERS.
4. ELEVATIONS NOTED ON A BEAM AS (#' - #") INDICATES THE CHANGE IN ELEVATION FROM THE NOTED T/STEEL ELEVATION.
5. BEAMS AND GIRDERS SUPPORTING OPEN-WEB ROOF JOISTS HAVE A T/STL ELEVATION OFFSET TO ACCOUNT FOR JOIST SEAT DEPTH.
THIS OFFSET SHALL BE COORDINATED WITH THE ACTUAL JOIST SEAT DEPTH AND THE STEEL FABRICATORS.
6. INDICATES THE SPAN DIRECTION FOR THE 3" METAL ROOF DECK FOR THE ROOF.R
7. INDICATES ROOF SLOPE DIRECTION. REFER TO ARCHITECTURAL DRAWINGS FOR
FINAL ROOF SLOPE AND PROFILE.
8. THE ROOF SHALL CONSIST OF 3" METAL ROOF DECK WITH RIGID INSULATION AND ROOFING
AS PER ARCHITECTURAL DRAWINGS AND DETAILS.
SLOPE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
Am en dm en t 6
-J
AN
-1
1st FLR T/SLAB 0' - 0"
2nd FLR T/STL 15' - 7"
2nd FLR T/SLAB 16' - 0"
ROOF T/DECK
31' - 10"
ROOF T/STL
31' - 7"
13 12 11 10 9 8 7 6 5 4 3 27.1
LOW ROOF T/STL
19' - 0"
AUD. ROOF T/STL
20' - 4"
S-210
Sim
1st FLR T/SLAB 0' - 0"
2nd FLR T/STL 15' - 7"
2nd FLR T/SLAB 16' - 0"
ROOF T/DECK
31' - 10"
ROOF T/STL
31' - 7"
1312111098765432 7.1
S-514
Sim
S-210
Sim
S-514
Sim
LEGEND:
LOUVER OPENINGS
HSS4x4x1/2 TUBE FRAMING
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
W
2D S-
-R
-0
1/27/2017 3:07:08 PM
S:\Projects\Ft_Drum\NCO Academy\Con_Docs\BIM_Models\Structural\NCOA-STRUCT.rvt
S-209
W
AL
L O
PE
N
IN
G
F R
AM
I N
G E
L E
VA
T I O
N S
N C
O A
C A D
EM
Y
C O
M
PL
E X
AM
P
AM
P
C he ck er
O C
T
, 2
NTS1 NORTH FRAMING ELEVATION
NTS2 SOUTH FRAMING ELEVATION
NOTES:
1. FRAMING SHOWN IS FOR TUBE STEEL MEMBERS AROUND ALL WINDOW, LOUVER, AND DOOR OPENINGS OF THE BUILDING ENVELOPE.
2. TUBE FRAMING IS TO BE PROVIDED AS PER UFC CRITERIA FOR BLAST LOADING. DOD MINIMUM WINDOWS AND DOORS SHALL
BE PROVIDED FOR ALL OPENINGS AS PER AT/FP REQUIREMENTS.
3. BETWEEN ALL TUBE FRAMING AND FOR THE REST OF THE STRUCTURE, FRAMING SHALL BE METAL STUDS @ 16" O.C. MAXIMUM.
SEE FRAMING DETAILS AND ARCHITECTURAL DRAWINGS.
4. CONNECTION DETAILS ARE PROVIDED IN THIS STRUCTURAL SUBMISSION. ALTERNATE CONNECTION DETAILS, DESIGNS, AND/OR MANUFACTURER PRODUCT DATA MAY BE SUBMITTED TO THE C.O.R. & S.E.O.R. FOR REVIEW & APPROVAL.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
Am en dm en t 6
-J
AN
-1
STUDS @ 16"
O.C.
TUBE FRAMING @ OPENING
TRACK
SLAB
STUDS @ 16" O.C.
ATTACH FOR BLAST TO VERT.
MEMBERS ONLY
STUDS @ 16" O.C.
S-210
Sim
S-210
Sim
ATTACH FOR BLAST TO VERT. MEMBERS
ONLY
STUDS @
16" O.C.
TRACK
SLAB
STUDS @
16" O.C.
TUBE FRAMING @ OPENING
S-210
Sim
S-210
Sim
1' - 0"
HSS6x6x1/2
L 3X3X3/8"
3/4" DIA. POST-INSTALLED
ANCHORS, 3 1/2" MIN EMBED.
3/16
SIDE OF DOOR
OPENING
HSS6x6x1/2
L 5X5X3/8"
3/4" DIA. POST-INSTALLED
ANCHORS, 3 1/2" MIN EMBED.
3/16
0'
6"
0' - 11"
HSS 6X6X1/2 VERT.
MEMBERS FOR FULL
HEIGHT (TYP)
ERECTION ANGLE
1st FLR T/SLAB 0' - 0"
2nd FLR T/STL 15' - 7"
2nd FLR T/SLAB 16' - 0"
ROOF T/DECK
31' - 10"
ROOF T/STL
31' - 7"
HGFEB C D F.1A E.1
LOW ROOF T/STL
19' - 0"
HSS8x6x1/2
S-514
Sim
S-210
Sim
1st FLR T/SLAB 0' - 0"
2nd FLR T/STL 15' - 7"
2nd FLR T/SLAB 16' - 0"
ROOF T/DECK
31' - 10"
ROOF T/STL
31' - 7"
H G F E BCDF.1 AE.1
AUD. ROOF T/STL
20' - 4"
HSS12x6x1/2 HSS12x6x1/2
S-514
Sim
S-514
Sim
S-210
Sim
S-210
Sim
W-SHAPE STEEL BEAM
W/ HSS COLUMN
ARCH WALL ASSEMBLY
1/4 6
1/4 6
HSS COLUMN
REFER TO ARCH WALL SECTIONS
VARIES
L6x4x3/8, L = 12", SLH
W/ SLOTTED HOLES
SECTION A - A'
(2) 3/4" A325 BOLTS
CONNECTING THROUGH
PLATE & ANGLE
A'
A
3/8" THICK PLATE
WELDED TO COLUMN
W/ SLOTTED HOLES
L6x4x3/8, L = 12"
WELDED TO
BEAM ABOVE
4.5 x 12 x 3/8" THICK PLATE
WELDED TO HSS COLUMN
6"
1/
2"
12"
HSS COLUMN
2" LONG SLOTTED HOLE
NOTE: SIMILAR CONNECTION DETAILS SHALL BE PROVIDED AT CONNECTION
OF HSS COLUMN TO STRUCTURAL SLABS. REFER TO CONNECTION
DETAILS FOR STEEL STUDS.
LEGEND:
LOUVER OPENINGS
HSS4x4x1/2 TUBE FRAMING
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D…