NCOA_Plumbing_Revised_Dwgs_Amend_7.pdf

PDF 2 MB Posted

Attached to
Non-Commissioned Officer (NCO) Academy Complex, Fort Drum, New York
Solicitation number
W912DS-17-R-0001
Issued by

About this file

W912DS-17-R-0001-0007 NCOA PLUMMING REVISED DRAWINGS

View the file

Other files

File Type Posted
C-751.pdf PDF
W912DS-17-R-0001-AMENDMENT_0012.pdf PDF
CP_NCOA-DMMA-CF.pdf PDF
W912DS-17-R-0001-0011.pdf PDF
W912DS-17-R-0001-AMENDMENT_0010.pdf PDF
W912DS-17-R-0001-0010_ET-602_Card_Access_System.pdf PDF
W912DS-17-R-0001-AMENDMENT_0009.pdf PDF
Plan_Set_-_REV1.pdf PDF
W912DS-17-R-0001-AMENDMENT_0008.pdf PDF
NCOA-STRUCT_Amendment7_31Jan2017.pdf PDF
Appendix_J_-_NOI__100__RTA_NCOA_SWPPP_rev01-31-2017-2.pdf PDF
Amend__7_SPECs_Reissued_02-01-17.pdf PDF
100__NCOA_SWPPP_rev01-31-2017_(No_Appendix).pdf PDF
W912DS-17-R-0001-AMENDMENT_0007.pdf PDF
100pcnt_LEED_Checklist_20160930.pdf PDF
ADDITIONAL_RFIs_20170126_REV.pdf PDF
NCOA_Civil_Dwgs_Amend_7.pdf PDF
W912DS-17-R-0001-0006.pdf PDF
W912DS-17-R-0001-0006.pdf PDF
W912DS-17-R-0001-AMENDMENT_0005.pdf PDF
Fort_Drum_Lab_Data-_500_Area_Buildings_excerpt.pdf PDF
Copy_of_Asbestos_DataRequest_20160315.pdf PDF
Amend__5_SPECs_Reissued_1-22-17.pdf PDF
Amend__5_Arch_Drawings_Reissued_1-20-17_.pdf PDF
C-GP0001_NCOA_Grading_Plan_bound.dwg DWG drawing
PLAN_SET.pdf PDF
C-GP0001_NCOA_Grading_Plan_converted.dgn —
Amend__5_Civil_drawings_reissued.pdf PDF
Fort_Drum_ACM_Report_-_500_Area_Buildings_excerpt.pdf PDF
Copy_of_Lead_DataRequest_20160315.pdf PDF
1-10-17_Site_Visit_Sign_In_roster.pdf PDF
W912DS-17-R-0001-AMENDMENT_0004.pdf PDF
NCOA_INT_REV1.pdf PDF
W912DS-17-R-0001-AMENDMENT_0003.pdf PDF
NCOA_revCivilSheets_12-29-2016.pdf PDF
Sign_In_Roster_for_NCOA_Site_Visit_20_DEC_2016.pdf PDF
W912DS-17-R-0001-AMENDMENT_0002.pdf PDF
RFI-0001_NCOA_DR-WDs.pdf PDF
W912DS-17-R-0001-0001.pdf PDF
Site_Visit_Map.pdf PDF
RTA_100PCNT_DESIGN_-_SPECS_SUBMISSION.pdf PDF
W912DS-17-R-0001_SOLICITATION_FOR_NCO_ACADEMY_COMPLEX_FORT_DRUM_NEW_YORK.pdf PDF
RTA_100PCNT_DESIGN_-_DRAWINGS_SUBMISSION.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

A

B

C

D

E

E.1

F

F.1

G

H

5 6 7 7.1 8 9

10 11 12

13 14

HWH-1P-3

P-3

P-3

P-3

P-1

P-1

P-1

P-1

P-5P-5

P-5 P-5 P-5

P-1 P-1

P-3

P-3

P-3

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-1

P-1

P-2

P-2 P-1P-1

P-1 P-1

P-3

P-3

P-3

P-4

P-4 P-4

P-4

P-4

STR

P-1P-3

OFFICE

OFFICE

OFFICE

COMMANDANT

CLOSET

127 OFFICE

OFFICE

OFFICE

OFFICE

VESTIBULE

ARMS ROOM

OFFICE

RECORDS ROOM

TRAINING OFFICE

COPY CNTR

TEST ROOM

STAFF BREAK

ROOM

CONF

STORAGE

TA-50 STORAGE

AUDITORIUM

TRAINING ACCESS

INSTRUCTIONAL

ACCESS

COMM

EMR

ELEV

INT. STAIR

ELEC

LAUNDRY

JAN CL / STO

BARRACK

BARRACK

BARRACK

BARRACK

BARRACK

MECH

W CADRE

LOCKERS

M CADRE

LOCKERS

W SHOWER/

LOCKERS

M SHOWER/

LOCKERS

145M SHOWER/

LOCKERS

RPZ

DCW

DHW

DCW

DHW

D C

W D

H W

DCW DHW

DCW

DHW

D C

W

D C

W

3 1/2"ø3 1/2"ø 3 1/2"ø

1" ø

1" ø

1" ø

2 1/2"ø2 1/2"ø2 1/2"ø

2" ø

2" ø2" ø2" ø

2" ø

1/

2" ø

2" ø

1/

4" ø

2"ø 2"ø 2"ø

1/ 2" ø

1/ 2" ø

1/

4" ø

DOMESTIC COLD WATER SUPPLY

P-1A

P-2A

P-4A

P-1A P-1A

P-1A

P-6

P-3

P-3

P-3

P-3

P-3 P-3 P-3

WH

DHWR DHWR DHWR

D H

W R

DHWR

DHWR

DHWR

3/ 4" ø

3/4"ø 3/4"ø 3/4"ø

3/ 4" ø

P-9

P-10

P-8

P-8

HWH-2

WH

WM

WM

WM

1/ 2" ø

DHW

D H

W R

3/4"ø

3/ 4" ø

3/4"ø

EL-WH-1

4" ø

4" ø

1/

2" ø

1/ 2" ø

2" ø

3/ 4" ø

3/4"ø

1/

2" ø

1/

2" ø 2 1/

2" ø

WH-BWH-B

WH-D

WATER METER

SEE PLUMBING DETAIL ON P-501

BACK FLOW PREVENTER

(REDUCED PRESSURE TYPE)

SEE PLUMBING DETAILS FOR CONNECTION

TO WATER METER.

WH-A

WH-A

WH-A

WH-A

WH-B WH-B WH-B WH-B

WH-A

WH-A

WH-C WH-D WH-D WH-B

WH-A

WH-A

WH-B

WH-B

WH-C

WH-C

PRESSURE REDUCING VALVE (PRV)

EX-T

WH

ADMIN SUITE

P-1

P-7

P-1

STAIR B

MAIN ENTRANCE

STORAGE

BARRACK ACCESS

P-2A

1" ø

1"ø

1" ø

SEE NOTE 6

P-3AP-3A

P-3A P-3AP-3A

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

P-101

PL

U

M

BI

N G

F

LO

O R

P L A

N B

N C

O A

C A D

EM

Y

C O

M

PL

E X N

EW

Y

O R

K N

EW

Y

O R

K , N

Y

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

D es ig ne r

Au th or

C he ck er

O C

TO

BE

R

0, W

2D S-

-R

-0

0-

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

C ha ng in g ta gs fo r w al l m ou nt ed la va to rie s to m at ch p lu m bi ng s ch ed ul e

Ja n

, 2

1/8" = 1'-0"P-101

1 FIRST FLOOR PLAN - PART B PLAN NORTH

NOTES:

1. ALL FLOOR PENETRATIONS SHALL BE PROVIDED WITH A PVC

SLEEVE SCHEDULE 40

2. ALL CW, HW AND HWR PIPES SHALL BE RUN ABOVE THE CEILING

AND COME DOWN IN THE CHASES PROVIDED BY THE ARCHITECT OR

BETWEEN THE WALL STUD FRAMES.

3. NATURAL GAS PIPING IS SHOWN ON THE MECHANICAL DRAWINGS

4. PROPOSED LAYOUT IN THE PLANS CAN BE CHANGED AND ADJUSTED

AS NEEDED, COR (CONTRCATING OFFICER REPRESENATIVE) WILL HAVE

FINAL DETERMINATION ON CHANGES.

5. THE PRESSURE REDUCING VALVE (PRV) SHALL BE DONE ON A PARALLEL

INSTALLATION WITH THE SMALLEST VALVE SETTING IN THE MAIN LINE. THE MAX.

PRESSURE SETTING SHALL BE AT 60 PSI. THE WATER PRESSURE IS 98 PSI

RIGHT NOW, CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL SIZING OF PRV

AND SETTING PRESSURE WHEN THE NEW HYDROSTATIC FLOW TEST IS

PERFORMED AFTER THE WATER LINE UPGREADE AT FT DRUM IS FINISHED.

6. COLD WATER SUPPLY TO THE WALL HYDRANT SHALL BE ROUTED UNDER THE

STAIRS.

SCALE:

0 8' 16'

1/8" = 1' - 0"

8' 16'

A

B

C

D

E

E.1

F

F.1

G

H

5 6 7 7.1 8 9

10 11 12

13 14

HWH-1

P-3

P-3

P-3

P-3

P-1

P-1

P-1

P-1

P-5P-5

P-5 P-5 P-5

P-1P-1

P-3

P-3

P-3

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-4

P-1

P-1

P-2

P-2 P-1P-1

P-1 P-1

P-3

P-3

P-3

P-4

P-4 P-4

P-4

P-4

S

S

S

S

SS

SEE CIVIL DRAWINGS FOR CONTINUATION

6 INCHES SANIATARY PIPE

4"ø 4"ø4"ø

5" ø

6" ø

4" ø

4" ø

4"ø

4" ø

3" ø

3" ø

3" ø

ARMS ROOM

OFFICE

AUDITORIUM

OFFICE

OFFICE

CLOSET

RR

OFFICE

OFFICE

OFFICE

OFFICE

VESTIBULE

ADMIN SUITE

STAFF BREAK

ROOM

COPY CNTR

TRAINING OFFICE

OFFICE

RECORDS ROOM

133 TEST ROOM

LOBBY

MECH

BARRACK

BARRACK

BARRACK

BARRACK

BARRACK

EMR

ELEV

INT. STAIR

COMM

ELEC

LAUNDRY

STAIR B

M CADRE

LOCKERS

W CADRE

LOCKERS

M SHOWER/

LOCKERS

W SHOWER/

LOCKERS

M SHOWER/

LOCKERS

STORAGE

TA-50 STORAGE

P-1A P-1A

P-1A

P-6

P-1P-3

P-3 P-3 P-3

FD-B

FD-B

FD-A

FD-A

FD-A

FD-AFD-A

FD-A

FD-A

P-7

P-3

P-3

P-3

P-3

P-10

P-1

EL-WH-1

P-10

P-9

P-8

P-8

FD-A

FD-A

P-1

FD-A

FD-C

FD-C

FD-C

FD-C

FD-C

FD-C

FD-C

WH-2

P-1A

SANITARY LINE COMING FROM THE SECOND FLOOR

STR

HWH-2

WM

WM

WM

CONF

COMMANDANT

0.25:12 0.25:12

0.

:1

0.

:1

0.25:12 0.25:12

0.

:1

2 1/2 IN. DIA. FLOOR DRAIN VENT (BURIED). CONNECT

TO THE NEAREST VENT STACK/BRANCH (TYP)

EX-T

1 1/2"ø

1 1/2"ø

0.

:1

0.25:12

SP-1

FCO FCOFCO

FCO S

FCO FCO FCOFCO

FCO

TRAINING ACCESS

INSTRUCTIONAL

ACCESS

INSTRUCTIONAL

ACCESS

FD-A

P-4A

BARRACK ACCESS

P-2A

P-2A

TRENCH DRAINS FOR SHOWERS TO BE

CONNECTED TO THE NEAREST SANITARY LINE

(TYP) FOR ALL

P-3A P-3A P-3A

P-3AP-3A

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

P-103

SA

N

IT

AR

Y

FI

R

ST

F

LO

O R

B

N C

O A

C A D

EM

Y

C O

M

PL

E X N

EW

Y

O R

K N

EW

Y

O R

K , N

Y

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

D es ig ne r

Au th or

C he ck er

O C

TO

BE

R

0, W

2D S-

-R

-0

0-

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

C ha ng in g ta gs fo r w al l m ou nt ed la va to rie s to m at ch p lu m bi ng s ch ed ul e

Ja n

, 2

1/8" = 1'-0"1 FIRST FLOOR SANITARY PLAN - PART B

PLAN NORTH

NOTES:

1. ALL SANITARY PIPING SHALL HAVE A 1/4 INCH PER FOOT SLOPE.

2. ALL SANITARY TEE CONNECTIONS SHALL BE OF THE TYPE Y-TYPE.

3. SANITARY LINE FROM SUMP-1 SHALL BE PROVIDED WITH AN INDIRECT

CONNECTION AND AIR GAP AT THE JANITOR'S CLOSET ROOM SINK.

4. ALL FLOOR DRAINS SHALL BE VENTED TO THE NEAREST VENT

BRANCH/STACK.

5. COORDINATE ALL PIPING ENTRY/EXIT BUILDING WITH CIVIL DISCIPLINE

PRIOR TO EXCAVATION AND CONCRETE WORK.

6. ALL SANITARY PIPING INSIDE THE BUILDING ARE BURIED BELOW

FINISHED FLOOR.

7. PROVIDE A CLEAN OUT ON EVERY TURN ON DIRECTION.

SCALE:

0 8' 16'

DN

A

B

C

D

E

E.1

F

F.1

G

H

5 6 7 7.1 8 9

10 11 12

13 14

CLASSROOM

CLASSROOM

LEARNING

RESOURCE

CENTER

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CLASSROOM

CLASSROOM

CLASSROOM

OFFICE

OFFICE

OFFICE

M RR

M RR

JAN CLOSET

OFFICE

OFFICE

COMM

MECH

J.C.

213B

ELEV

215 ELEC

STUDENT BREAK

AREA

BARRACK

BARRACK

BARRACK

BARRACK

STAIR B

F RR

2 1/2"ø 1 1/2"ø

1/

2" ø

1/

2" ø

2" ø

1/

2" ø

2 1/2"ø 1 1/2"ø

2"ø 1 1/2"ø

P-1

P-1

P-1

P-1

P-1P-2

P-2

P-2

P-2

P-2

P-1

P-1

P-3 P-3

P-3

P-3

P-3

P-3P-3

P-3

P-3

P-3

P-1 P-1

P-1 P-1

P-1

DCWDHW

DCW

DHW

DCW

DHW

D C

W

D C

W D

H W

DHWR DHWR

DHWR DHWR 3/4"ø3/4"ø

3/4"ø

3/ 4" ø

P-7 P-7

P-8

WH-D

WH-C

WH-C

WH-C

D H

W

WH-AWH-A

3/ 4" ø

3/ 4" ø

1/ 2" ø

1/ 2" ø

CW & HW FROM FIRST FLOOR

MECHANICAL ROOM

HOT WATER RETURN

GOING DOWN

P-6

STORAGE

213A

P-2

P-2

P-1A

INSTRUCTIONAL

ACCESS

INTERTITIAL

SPACE

INSTRUCTIONAL

ACCESS

P-2A

P-5P-5

P-5 P-5P-5

P-3A P-3A

P-3AP-3AP-3A

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

P-105

PL

U

M

BI

N G

S

EC

O N

D F

LO

O

R B

N C

O A

C A D

EM

Y

C O

M

PL

E X N

EW

Y

O R

K N

EW

Y

O R

K , N

Y

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

D es ig ne r

Au th or

C he ck er

O C

TO

BE

R

0, W

2D S-

-R

-0

0-

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

C ha ng in g ta gs fo r w al l m ou nt ed la va to rie s to m at ch p lu m bi ng s ch ed ul e

Ja n

, 2

1/8" = 1'-0"1 SECOND FLOOR PLAN - PART B

PLAN NORTH

NOTES:

1. ALL FLOOR PENETRATIONS SHALL BE PROVIDED WITH A PVC

SLEEVE SCHEDULE 40

2. ALL CW, HW AND HWR PIPES SHALL BE RUN ABOVE THE CEILING

AND COME DOWN IN THE CHASES PROVIDED BY THE ARCHITECT.

3. NATURAL GAS PIPING IS SHOWN ON THE MECHANICAL DRAWINGS.

SCALE:

0 8' 16'

A

B

C

D

E

E.1

F

F.1

G

H

6 7 7.1 8 9

10 11 12

13 14

CLASSROOM

4" ø

4"ø

4" ø

4"ø 4"øS

S

S

S

3" ø

P-1

P-1

P-1

P-1

P-1P-2

P-2

P-2

P-2

P-2

P-3 P-3

P-3

P-3

P-3

P-3P-3

P-3

P-3

P-3

P-1 P-1

P-1 P-1

P-1 P-5 P-5P-5

P-5 P-5

P-6

CLASSROOM

P-7

P-8

FD-A

LEARNING

RESOURCE

CENTER

OFFICE

OFFICE

INTERTITIAL

SPACE

INSTRUCTIONAL

ACCESS

INSTRUCTIONAL

ACCESS

CLASSROOM

CLASSROOM

COMM

MECH

ELEV

J.C.

213B

ELEC

202 STUDENT BREAK

AREA

BARRACK

BARRACK

BARRACK

BARRACK

BARRACK

F RR

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CLASSROOM

M RR

M RR

STORAGE

213A

INT. STAIR

0.

:1

0.25:12

0.25:12

0.

:1

GOING DOWN TO FIRST FLOOR FD-B

FD-B

OFFICE

FCO

FCO FCO

FCO

FCO

FCO

FCO

FCO

P-1A

P-2

P-2

FD-A

FD-A

P-7

P-2A

0.25:12

P-1

P-1A

P-3A P-3A P-3A

P-3AP-3A

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

P-106

SA

N

IT

AR

Y

SE

C O

N D

F L O

O R

N C

O A

C A D

EM

Y

C O

M

PL

E X N

EW

Y

O R

K N

EW

Y

O R

K , N

Y

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

D es ig ne r

Au th or

C he ck er

O C

TO

BE

R

0, W

2D S-

-R

-0

0-

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

C ha ng in g ta gs fo r w al l m ou nt ed la va to rie s to m at ch p lu m bi ng s ch ed ul e

Ja n

, 2

1/8" = 1'-0"1 SECON FLOOR SANITARY PLAN

PLAN NORTH

NOTES:

1. ALL SANITARY PIPING SHALL HAVE A 1/4 INCH PER FOOT SLOPE.

2. ALL SANITARY TEE CONNECTIONS SHALL BE OF THE TYPE Y-TYPE.

3. ALL FLOOR DRAINS SHALL BE VENTED TO THE NEAREST VENT

BRANCH/STACK.

4. COORDINATE ALL PIPING ENTRY/EXIT BUILDING WITH CIVIL DISCIPLINE

PRIOR TO EXCAVATION AND CONCRETE WORK.

5. ALL SANITARY PIPING INSIDE THE BUILDING ARE BURIED BELOW

FINISHED FLOOR.

SCALE:

0 8' 16'

P-601

P L

U M

B

IN

G S

C H

E D

U L E

S I

S C

H E

D U

L E R

E V

IS

IO

N

US Army Corps of Engineers fi

SHEET ID

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I ’D

F

IL

E N

A M

E

IS

S

U E D

A T

E

C O

N T

R A

C T N

O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N C

O A

C A

D E

M Y C

O M

P L E

X

N E

W Y

O R

K

N E

W Y

O R

K

N Y

F

E D

E R

A L P

L A

Z A

R O

O M

N E

W Y

O R

K

N Y

-0

C h e c k e r

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

F W

B

F W

B

O C

T O

B E

R

W

D S -1

-R -0

Sheets
P-101 - PLUMBING FLOOR PLAN B
P-103 - SANITARY FIRST FLOOR B
P-105 - PLUMBING SECOND FLOOR B
P-106 - SANITARY SECOND FLOOR
P-103 - SANITARY FIRST FLOOR B.PDF
Sheets
P-101 - PLUMBING FLOOR PLAN B
P-103 - SANITARY FIRST FLOOR B
P-105 - PLUMBING SECOND FLOOR B
P-106 - SANITARY SECOND FLOOR
P-105 - PLUMBING SECOND FLOOR B.PDF
Sheets
P-101 - PLUMBING FLOOR PLAN B
P-103 - SANITARY FIRST FLOOR B
P-105 - PLUMBING SECOND FLOOR B
P-106 - SANITARY SECOND FLOOR
P-106 - SANITARY SECOND FLOOR.PDF
Sheets
P-101 - PLUMBING FLOOR PLAN B
P-103 - SANITARY FIRST FLOOR B
P-105 - PLUMBING SECOND FLOOR B
P-106 - SANITARY SECOND FLOOR

File details come from the government source that posted it. Updated .