Pre-Demolition Survey Report
Fort Drum Military Reservation, New York
Contract Number: W912DY-11-D-0026
Date: January 9, 2012
Prepared for:
U.S. Army Engineering and Support Center Huntsville, Alabama
Prepared By:
Great Southern Engineering, Incorporated 3795 Gordon Terry Parkway Trinity, Alabama 35673 256-350-9754
Executive Summary
Great Southern Engineering, Incorporated (GSE) was contracted by the U.S. Army Engineering and Support Center in Huntsville, Alabama to perform a Pre-Demolition Survey for one hundred ninety four (194) buildings/structures at the Fort Drum in New York during Phase II of the Fort
Drum Pre-Demolition Survey effort. This work was performed under Contract Number
W912DY-11-D-0026. The field portion of the work was completed on November 28, 2011. The following summarizes the project personnel for this installation:
USACE Contact: Mindy Shelton
Site Point of Contact: Rick Nuijens
GSE Principal-in-Charge: Kaye Meeks
GSE Project Manager: Jeff Smith
Asbestos Inspectors: Chris Bradford, Nevin Bradford, Tim Kordek, Jamie Pentland, Joshua Sandberg and Jeff Smith
ORM Inspectors: Chris Bradford, Nevin Bradford, Tim Kordek, Jamie Pentland, Joshua Sandberg and Jeff Smith
Explosives Residue Screening: Not Applicable
This report documents GSE’s work for this task order. Our findings are summarized below:
Asbestos Containing Material (ACM) and other regulated materials (ORMs) were found in various buildings during this investigation.
Screening for the presence of explosives residue was not conducted as part of GSE’s scope of services.
Purpose
The purpose of this task is to complete Pre-Demolition Surveys of the referenced facilities at
Fort Drum Military Reservation to identify significant sources, location and estimated quantities of ACMs and ORMs. ORMs included fluorescent light fixtures, lighted exit signs, smoke detectors, fire extinguishers, transformers, air conditioners and chiller units, thermostats, electric control panels, drinking water fountains, generators, circuit breakers, batteries and battery chargers.
Limitations
The following limitations apply to this survey:
1. The buildings were grouped by CAT Code and square footage. At the direction of
USACE, only one building from each group was surveyed. Buildings that did not fit into the grouping criteria were individually surveyed.
2. GSE initially identified areas where USTs may exist or may have previously existed.
The survey crew was told by Mr. John Ashcraft, Ft. Drum Real Estate, that many of the tanks had been removed and that all of the remaining fuel oil tanks are currently being removed from the Post. The contractor responsible for the removal is to be finished by
September 30, 2011. Therefore, GSE did not provide a complete inventory fuel oil USTs as part of this investigation.
3. GSE attempted to identify all materials, but some may exist that were beyond reasonable access to the inspectors during the site visit. GSE attempted to access crawl spaces, wall cavities, sub-floors, vaults, hidden/concealed conditions, locked rooms or similar areas only if the areas were considered safe and reasonably accessible by field personnel.
4. Materials that were not considered a “suspect asbestos-containing material” were not sampled. These non-suspect materials included silicone, foam rubber, fiberglass, wood, glass, and metal.
5. Older flooring materials (i.e., 9x9 floor tile) were covered by a newer layer of plywood and flooring materials in several buildings. Observations were made in buildings where penetrations previously had been drilled through the floor. This condition may exist in other buildings.
6. Electrical wiring was live at the time of the survey and therefore was not sampled in any building.
Site Activities
Per the direction of USACE, buildings having the same square footage and CAT Codes were grouped together and only one building in each group was surveyed. The results from that building are applied to all buildings in the group. Some materials, such as 9”x9” floor tile, may be assumed to contain asbestos by GSE’s field personnel. If a material is assumed to contain asbestos, then samples were not collected from that material.
GSE conducted the inspections of the buildings to determine the presence of asbestos-containing materials (ACM), other regulated materials (ORM). As directed by the USACE, the asbestos surveys were completed to comply with the federal National Emission Standard for
Hazardous Air Pollutants (NESHAP – 40 CFR 61, Subparts A & M). No ORM samples were collected. ACM samples were collected in accordance with applicable federal regulations and subsequently submitted to a NVLAP-accredited laboratory for testing. Polarized Light
Microscopy (PLM) was the analytical method employed to analyze the samples using positive stop procedures. Positive stop means that once a positive (greater than 1% asbestos) result is obtained, the remaining samples for that material are not analyzed.
The following table provides a list of the buildings included in this task order. The shaded buildings represent groups of buildings with the same CAT CODE and square footage. Only one building from each group was surveyed. The buildings listed in red indicate the buildings that were surveyed from that group. The buildings not shaded indicate buildings that were surveyed individually.
BUILDING NUMBER CATCD BUILDING FUNCTION SF
4752 75052 REC SHELTER 221
4754 75052 REC SHELTER 221
4759 75052 REC SHELTER 221
1388 89120 PLT/UTIL BLDG 296
4779 89120 PLT/UTIL BLDG 296
2260 72350 GARAGE UPH DET 384
4707 72350 GARAGE UPH DET 384
2253 72010 ARMY LODGING 607
2254 72010 ARMY LODGING 607
2255 72010 ARMY LODGING 607
2256 72010 ARMY LODGING 607
2257 72010 ARMY LODGING 607
306* 14185 CO HQBLDG 1,144
561 14185 CO HQBLDG 1,144
562 14185 CO HQBLDG 1,144
4881 14185 CO HQBLDG 1,144
7* 61050 ADMIN GEN PURP 1,144
131 61050 ADMIN GEN PURP 1,144
1001 61050 ADMIN GEN PURP 1,750
1003 61050 ADMIN GEN PURP 1,750
2248 44220 STORAGE GP INST 2,250
4893 44220 STORAGE GP INST 2,250
540 44220 STORAGE GP INST 2,360
550 44220 STORAGE GP INST 2,360
9 61050 ADMIN GEN PURP 2,892
20 61050 ADMIN GEN PURP 2,892
514 17120 GEN INST BLDG 3,663
515 17120 GEN INST BLDG 3,663
1644* 21410 VEH MAINT SHOP 4,166
1174 21410 VEH MAINT SHOP 4,166
1444* 21410 VEH MAINT SHOP 4,238
1255 21410 VEH MAINT SHOP 4,238
541 17120 GEN INST BLDG 4,720
542 17120 GEN INST BLDG 4,720
543 17120 GEN INST BLDG 4,720
10 61050 ADMIN GEN PURP 4,720
11 61050 ADMIN GEN PURP 4,720
45 61050 ADMIN GEN PURP 4,720
46 61050 ADMIN GEN PURP 4,720
122 61050 ADMIN GEN PURP 4,720
141 61050 ADMIN GEN PURP 4,720
441 72111 ENLISTED UPH 4,720
442 72111 ENLISTED UPH 4,720
443 72111 ENLISTED UPH 4,720
444 72111 ENLISTED UPH 4,720
451 72111 ENLISTED UPH 4,720
452 72111 ENLISTED UPH 4,720
453 72111 ENLISTED UPH 4,720
454 72111 ENLISTED UPH 4,720
471 72111 ENLISTED UPH 4,720
472 72111 ENLISTED UPH 4,720
473 72111 ENLISTED UPH 4,720
474 72111 ENLISTED UPH 4,720
551 72122 TRANS UPH AST 4,720
552 72122 TRANS UPH AST 4,720
553 72122 TRANS UPH AST 4,720
571 72122 TRANS UPH AST 4,720
27 55010 HEALTH CLINIC 5,152
28 55010 HEALTH CLINIC 5,152
124 61050 ADMIN GEN PURP 5,310
4848 61050 ADMIN GEN PURP 5,310
4871 61050 ADMIN GEN PURP 5,310
572 72122 TRANS UPH AST 5,310
573 72122 TRANS UPH AST 5,310
4894 61050 ADMIN GEN PURP 6,490
4895 61050 ADMIN GEN PURP 6,490
1172 21410 VEH MAINT SHOP 7,219
1345 21410 VEH MAINT SHOP 7,219
2201 72010 ARMY LODGING 7,670
2202 72010 ARMY LODGING 7,670
2203 72010 ARMY LODGING 7,670
2204 72010 ARMY LODGING 7,670
2205 72010 ARMY LODGING 7,670
2207 72010 ARMY LODGING 7,670
2208 72010 ARMY LODGING 7,670
2210 72010 ARMY LODGING 7,670
2211 72010 ARMY LODGING 7,670
2212 72010 ARMY LODGING 7,670
2213 72010 ARMY LODGING 7,670
2217 72010 ARMY LODGING 7,670
88* 44220 STORAGE GP INST 9,267
65 44220 STORAGE GP INST 9,267
69 44220 STORAGE GP INST 9,267
74 44220 STORAGE GP INST 9,267
75 44220 STORAGE GP INST 9,267
80 44220 STORAGE GP INST 9,267
98 44220 STORAGE GP INST 9,267
4 61050 ADMIN GEN PURP 5,772
15 21845 ADMIN/SHOP DOL 3,742
29 55010 HEALTH CLINIC 4,720
30 14185 CO HQBLDG 26,693
44 21910 ENG/HOUSING MNT 2,910
55 74078 THRIFT SHOP 8,425
68 44220 STORAGE GP INST 9,345
70 44224 ORG STR BLDG 9,267
73 44220 STORAGE GP INST 9,507
78 74055 EXCH WAREHOUSE 10,491
79 44271 HSG FURN STR 10,491
84 21835 REPAIR BAYS DOL 14,606
85 21845 ADMIN/SHOP DOL 2,284
86 89121 HEALTH PLT BLDG 672
87 44220 STORAGE GP INST 360
91 21910 ENG/HOUSING MNT 22,815
92 74060 BREAK/LUNCH RM 3,108
93 21925 ENGR MAINT FAC 18,240
97 73032 PICKUP POINT 14,008
101 61050 ADMIN GEN PURP 2,305
120 61050 ADMIN GEN PURP 2,488
121 61050 ADMIN GEN PURP 4,876
126 14184 BN HQ BLDG TI 5,310
128 13181 TERM EQP FAC 700
129 13185 PRINT PLANT 3,696
130 61050 ADMIN GEN PURP 2,588
132 44224 ORG STR BLDG 1,144
140 61075 COURTROOM 3,253
148 74085 PVT/ORG CLUB 4,720
191 61050 ADMIN GEN PURP 2,096
198 21910 ENG/HOUSING MNT 8,940
313 17115 BAND TRAIN BLDG 3,663
503 76010 MUSEUM 2,284
513 76011 MUSEUM SPT BLDG 1,726
544 14185 CO HQBLDG 2,750
545 44220 STORAGE GP INST 2,500
560 14185 CO HQBLDG 3,131
574 72210 DINING FACILITY 3,007
1002 61050 ADMIN GEN PURP 3,108
1030 14129 TNG AIDS CTR 12,753
1123 21910 ENG/HOUSING MNT 8,221
1124 61050 ADMIN GEN PURP 12,954
1125 44223 ARMS STORAGE‐BN 4,932
1131 44220 STORAGE GP INST 7,219
1132 21910 ENG/HOUSING MNT 7,795
1141 21910 ENG/HOUSING MNT 7,219
1142 21910 ENG/HOUSING MNT 8,179
1143 21910 ENG/HOUSING MNT 3,108
1151 44220 STORAGE GP INST 13,024
1162 44220 STORAGE GP INST 992
1176 44224 ORG STR BLDG 379
1275 44220 STORAGE GP INST 1,634
1454 21410 VEH MAINT SHOP 6,566
1555 21406 VEH MAINTTI 4,166
1699 84141 PUMP STAAT POT 354
1734 44220 STORAGE GP INST 8,580
2045 89121 HEAT PLT BLDG 750
2046 13320 NAV BLDG, AIR 420
2047 89144 WTR SUP BLD NP 990
2049 14112 AVN UNIT OPS 4,137
2140 12450 MOGAS STR UNGD 23,240
2150 21910 ENG/HOUSING MNT 11,531
2162 21870 MNT STORAGE DOL 355
2166 89120 PLT/UTIL BLDG 3,393
2190 74068 RECREATION CTR 6,396
2209 72410 UOQ MILITARY 7,670
2220 17119 ORG CLASSROOM 6,805
2226 61050 ADMIN GEN PURP 1,976
2227 61050 ADMIN GEN PURP 2,250
2251 72010 ARMY LODGING 1,220
2252 72010 ARMY LODGING 969
2258 72010 ARMY LODGING 460
2259 72010 ARMY LODGING 672
2300 74050 EXCHANGE BRANCH 29,260
2312 14161 EMERG OPNS CNTR 4,129
2360 17138 LIMIT USE INST 27,295
2365 44220 STORAGE GP INST 1,350
2379 89120 PLT/UTIL BLDG 150
2507 17120 GEN INST BLDG 3,851
2509 61050 ADMIN GEN PURP 5,482
2552 44220 STORAGE GP INST 9,000
2707 14113 ACCESS CNT FAC 130
2803 44220 STORAGE GP INST 860
2808 74085 PVT/ORG CLUB 2,040
3829 21410 VEH MAINT SHOP 2,506
3894 44220 STORAGE GP INST 1,250
3895 17138 LIMIT USE INST 1,750
3897 17119 ORG CLASSROOM 7,849
3898 17119 ORG CLASSROOM 2,740
4000 61050 ADMIN GEN PURP 12,767
4001 44222 STR SHED GP INS 4,800
4003 21910 ENG/HOUSING MNT 7,360
4004 21910 ENG/HOUSING MNT 15,584
4012 14180 SCALE HOUSE 704
4705 75052 REC SHELTER 600
4753 75052 REC SHELTER 375
4801 74085 PVT/ORG CLUB 5,310
4808 14183 BN HQ BLDG 5,310
4814 21415 COMP ITEM REP 2,592
4818 61050 ADMIN GEN PURP 1,250
4828 44224 ORG STR BLDG 1,250
4836 76010 MUSEUM 5,310
4838 61050 ADMIN GEN PURP 2,715
4839 61050 ADMIN GEN PURP 2,282
4840 17119 ORG CLASSROOM 2,500
4849 17123 RG SPT FAC 2,250
4850 14185 CO HQBLDG 2,592
4884 61050 ADMIN GEN PURP 4,465
4890 44220 STORAGE GP INST 2,395
6000 21410 VEH MAINT SHOP 30,588
6001 44220 STORAGE GP INST 7,540
6004 44228 HAZ MAT STR INS 400
*Building surveyed during Phase 1
BUILDING DETAILS
BUILDING 306
Applies to Buildings: 306**, 561, 562, 4881
** Bldg. 306 was completed during the Phase 1 Survey
CAT Code Description: 14185 CO HQ BLDG
Summary of Findings
ACM Present: Yes
ORMs Present: Yes
Explosives Screening Done: No
If Yes, was it present?
Describe:
NA
Construction Details:
Building Size: 1,144 SF
Date Constructed: Not Reported
Number of Floors:
(not including Basement)
Basement Present: No
Framing: Wood
Foundation Type: Pier and Beam
Foundation Material: Concrete and Wood
Roof Style: Pitched
Roof Material: Standing Seam Metal
Exterior Wall Composition: Sheet Metal over Wood
Building Observations:
Current Use: Vacant
Building Condition: Intact
Other:
Building 306 – ACM & ORM Summary
Material Description Notes Quantity
Asbestos-Containing Materials (ACMs)
Black Sealer 9LF
Flue Insulation w/ Metal Jacket Chimney 1 Chimney
Other Regulated Materials (ORMs)
Light Fixtures – Interior & Exterior
Standard
Metal Halide, Sodium, etc. 2
4 ft Fluorescent Light Fixtures Throughout 10
4 Tubes each Fixture 40
1 Non-PCB Ballasts each Fixture 10
PCB Ballasts each Fixture
Electrical Panels / Fuse Boxes 2
Emergency Lights with Battery(ies) 2
Exit Signs: Illuminated 2
Furnaces 1
Gas Meters 1
HVAC Units: Small Units 1
Thermostats 1 SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM EA = Each Cr = Crocidolite SD = Significantly Damaged NF2 = Category II Non-Friable ACM ND = None Detected PS = Positive Stop
Building 306 – ACM Sample Inventory Sample Number
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
306-01 Sheetrock and Joint Compound North Wall Drywall Material – ND Joint Compound - ND
306-02 Sheetrock and Joint Compound South Wall
Joint Compound - ND
306-03 2’ x 4’ Suspended Ceiling Tile East End Acoustic Tile - ND
306-04 2’ x 4’ Suspended Ceiling Tile West End Acoustic Tile - ND
306-05 Vinyl Cove Base (Grey) and Mastic
West End Cove Base – ND
Yellow Mastic - ND
306-06 Vinyl Cove Base (Grey) and Mastic
North Wall
306-07 Carpet Mastic (Yellow) West End Floor Tile – ND
306-08 Carpet Mastic (Yellow) East End
306-09 Insulation Mastic (Paper Faced, Yellow Fiberglass)
North Wall Exterior
Thermal Insulation – ND Paper – ND
Black Mastic - ND
306-10 Insulation Mastic (Paper Faced, Yellow Fiberglass)
South Wall Exterior
Thermal Insulation – ND Paper – ND
Black Mastic - ND
306-11 12” x 12” Floor Tile (Green) and Mastic
West End
306-12 12” x 12” Floor Tile (Green) and Mastic
East End
306-13 12” x 12” Floor Tile (White) and Mastic
West End
306-14 12” x 12” Floor Tile (White) and Mastic
East End
306-15 Cork Board Mastic (Yellow) SW End Yellow Mastic - ND
306-16 Cork Board Mastic (Yellow) SW End Yellow Mastic - ND
306-17 Vinyl Cove Base (Brown) with Mastic (Yellow)
East End Vestibule
306-18 Vinyl Cove Base (Brown) with Mastic (Yellow)
East End Vestibule
306-19 Vibration Cloth (Black) Furnace
Mechanical Room
Isolator Material - ND
306-20 Vibration Cloth (Black) Furnace
Mechanical Room
Isolator Material - ND
306-21 Sheetrock North Wall
Center
Texture - ND
306-22 Sheetrock North Wall
Center
Texture - ND
-- Flue Insulation w/ Metal Jacket Chimney Assumed Positive 1 Chimney G F
306-101 Tar Paper Under Metal
Roof Tar Paper=ND
306-102 Tar Paper Under Metal
Roof Tar Paper=ND
306-103 Sealer (Black) Chimney Sealant – 5% Ch 9 LF G NF1
Number
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
306-104 Sealer (Black) Chimney PS 9 LF G NF1
306-105 Asphalt Shingle (Brown) Chimney Roofing Shingle - ND
306-106 Asphalt Shingle (Brown) Chimney Roofing Shingle - ND
SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM
Building 306 – Photographs
Building Exterior - Note Chimney
Roof Chimney with Black Sealer
S. HEMMING
September 7, 2011
FORT DRUM
Pre-Demolition Survey
FigureDrawn
Title:
Checked
Project:
Not To Scale
BUILDING 306
Sample Location Map
S. MCCUTCHEON
September 7, 2011
FORT DRUM
Pre-Demolition Survey
FigureDrawn
Title:
Checked
Project:
Not To Scale
BUILDING 306
Sample Location Map
VENT
VENT
CHIMNEY
ROOF
September 7, 2011
S. MCCUTCHEON
FORT DRUM
Pre-Demolition Survey
BUILDING 306
ACM Location Map
FigureDrawn
Title:
Checked
Project:
Asbestos-Containing BLACK ROOF SEALER
Not To Scale
VENT
VENT
CHIMNEY
ROOF
ACM Black Roof Sealer
September 7, 2011
S. MCCUTCHEON
FORT DRUM
Pre-Demolition Survey
BUILDING 306
ACM Location Map
FigureDrawn
Title:
Checked
Project:
Presumed Asbestos-Containing DOUBLE METAL WALL CHIMNEY
Not To Scale
VENT
VENT
CHIMNEY
ROOF
Presumed ACM Double Metal Wall Chimney
BUILDING 513
Applies to Buildings: 513 Only
CAT Code Description: 76011 MESEUM SPT BLDG
Summary of Findings
ACM Present: Yes
ORMs Present: Yes
Explosives Screening Done: No
If Yes, was it present?
Describe:
NA
Construction Details:
Building Size: 1726 SF
Date Constructed: Not Reported
Number of Floors:
(not including Basement)
Basement Present: No
Framing: Wood
Foundation Type: Pier and Beam
Foundation Material: Concrete and Wood
Roof Style: Pitched
Roof Material: Standing Seam Metal
Exterior Wall Composition: Sheet metal Over Wood
Building Observations:
Current Use: NCOA Chief of Training Offices
Building 513 – ACM & ORM Summary
Exterior Window Glazing Compound 675 LF
Other Regulated Materials (ORMs)
Light Fixtures – Interior & Exterior
Standard 3
4 ft Fluorescent Light Fixtures 15
2 Tubes each Fixture Throughout 30
1 Non-PCB Ballasts each Fixture 15
1 ft Fluorescent Light Fixtures 2
1 Tubes each Fixture Bathroom 2
1 Non-PCB Ballasts each Fixture 2
Electrical Panels / Fuse Boxes 3
Emergency Lights with Battery(ies) 1
Exit Signs: Illuminated 2
Fire Extinguishers 1
Furnaces 1
Gas Meters 1
Hot Water Heaters 1
HVAC Units: Window Units 1
Smoke Detectors 4
Thermostats 2
SF – Square Feet LF – Linear Feet EA – Each
Building 513 – ACM Sample Inventory
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
513-01 Electrical Penetration Sealer (Red)
Mechanical Room Sealer = ND
513-02 Electrical Penetration Sealer (Red)
Mechanical Room Sealer = ND
513-03 Vibration Isolators Mechanical Room Isolator Material = ND
513-04 Vibration Isolators Mechanical Room Isolator Material = ND
513-05 End Cap Sealer (White) on Fiberglass Pipe Insulator
Mechanical Room Thermal Insulation = ND Paper/Foil Wrap = ND
White Mastic = ND
513-06 End Cap Sealer (White) on Fiberglass Pipe Insulator
Mechanical Room Thermal Insulation = ND
513-07 Sheetrock and Joint Compound Southwest Office Drywall Material = ND Joint Compound = ND
513-08 Sheetrock and Joint Compound Mechanical Room
513-09 Vinyl Core Base (Black) with Mastic (Tan)
Northwest Storage Cove Base = ND Tan Mastic = ND
513-10 Vinyl Core Base (Black) with Mastic (Tan)
Southwest Office
513-11 12” x 12” Floor Tile (Brown) with Mastic (Black)
Southwest Office Floor Tile = ND
Black Mastic = ND
513-12 12” x 12” Floor Tile (Brown) with Mastic (Black)
Southwest Office
513-13 Insulation Mastic (Black) Attic Access Thermal Insulation = ND Paper/Tar Wrap = ND
513-14 Insulation Mastic (Black) Attic Access
Paper/Tar Wrap = ND
513-15 Wall Panel Mastic (White) Northwest Storage White Mastic = ND
513-16 Wall Panel Mastic (White) Northwest Storage White Mastic = ND
513-17 Exterior Window Glazing Compound
West Side Window
Glazing = 2% Ch 675 LF G NF2
513-18 Exterior Window Glazing Compound
South Side Window
PS 675 LF G NF2
513-19 Wainscoting Mastic (Tan) North Side Entry
Way Tan Mastic = ND
513-20 Wainscoting Mastic (Tan) Latrine Tan Mastic = ND
513-101 Glue Down EPDM / Isocyanurate Insulation
East Shed Rubber Membrane = ND Paper/Foil Facing = ND Foam Insulation = ND
513-102 Glue Down EPDM / Isocyanurate Insulation
East Shed Rubber Membrane = ND Paper/Foil Facing = ND Foam Insulation = ND
513-103 Fabric (Black) / EPDM Under SSR Fabric = ND
Membrane = ND Tar = ND
513-104 Fabric (Black) / EPDM Under SSR
Membrane = ND Tar = ND
Building 513 – Photographs
Building Exterior Building Exterior
Window Glazing Window Glazing
11/15/2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0513
Sample Location Map
J. SMITH
1st Floor
09 11
16 15
11/15/2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0513
Sample Location Map
J. SMITH
Roof
103 104
No ACM Reported
11/15/2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0513
ACM Location Map
J. SMITH
Asbestos-Containing WINDOW GLAZING
ACM Window Glazing 1st Floor
BUILDING 515
Applies to Buildings: 514 & 515
CAT Code Description: 17120 GEN INST BLDG
Summary of Findings
ACM Present: Yes
ORMs Present: Yes
Explosives Screening Done: No
If Yes, was it present?
Describe:
NA
Construction Details:
Building Size: 3663 SF
Date Constructed: Not Reported
Number of Floors:
(not including Basement)
Basement Present: No
Framing: Wood
Foundation Type: Pier and Beam
Foundation Material: Concrete and Wood
Roof Style: Pitched
Roof Material: Metal
Exterior Wall Composition: Metal
Building Observations:
Current Use: Occupied – Offices and Training
Building 515– ACM & ORM Summary
12” x 12” Floor Tile (Tan with Brown, White, and Pink Specks)
Exposed and under carpet 3400 SF
Flue Insulation W/ Metal Jacket 30 LF
Other Regulated Materials (ORMs)
Light Fixtures – Interior & Exterior
Standard 4
4 ft Fluorescent Light Fixtures 33
4 Tubes each Fixture 132
1 Non-PCB Ballasts each Fixture 33
1 PCB Ballasts each Fixture 33
Electrical Panels / Fuse Boxes 3
Emergency Lights with Battery(ies)
Exit Signs: Illuminated 2
Exit Signs: Reflective
Fire Extinguishers 2
Furnaces 1
Gas Meters 1
Hot Water Heaters 1
HVAC Units: Window Units 3
Thermostats 3
Water Coolers 1
SF – Square Feet
Building 515 – ACM Sample Inventory
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
515-01 Window Glazing Southwest
Corner Window Glazing = ND
515-02 Window Glazing East Corner Window Glazing = ND
515-03 Wall and Ceiling System Room 2
515-04 Wall and Ceiling System Room 1
515-05 Vibration Isolators Room 2 Isolator Material = ND
515-06 Vibration Isolators Room 2 Isolator Material = ND
515-07 Putty, HVAC Duct Joints Room 2 Putty = ND
515-08 Putty, HVAC Duct Joints Room 2 Putty = ND
515-09 Mastic, Pipe Insulation with Paper Cover
Room 2 Thermal Insulation = ND Paper Foil Wrap = ND
515-10 Mastic, Pipe Insulation with Paper Cover
Room 2 Thermal Insulation = ND Paper Foil Wrap = ND
515-11 12” x 12” Floor Tile (Tan w/ Brown, White, and Pink Specks) & Mastic
Room 4 Floor Tile = 3% Ch Black Mastic = ND
3400 SF G NF2
515-12 12” x 12” Floor Tile (Tan w/ Brown, White, and Pink Specks) & Mastic
Room 10 Floor Tile = 3% Ch Black Mastic = ND
3400 SF G NF2
515-13 12” x 12” Floor Tile (Beige with Brown Mottles) and Mastic, Patch
Room 3
515-14 12” x 12” Floor Tile (Beige with Brown Mottles) and Mastic, Patch
Room 3
515-15 Sink Undercoating Room 1 Sink Undercoating = ND
515-16 Sink Undercoating Room 1 Sink Undercoating = ND
515-17 2’ x 4’ Ceiling Tile Room 5 Acoustic Tile = ND
515-18 2’ x 4’ Ceiling Tile Room 7 Acoustic Tile = ND
515-19 Carpet (Maroon) and Mastic Room 7 Carpet = ND
Yellow Mastic = ND
515-20 Carpet (Maroon) and Mastic Room 7 Carpet = ND
515-101 Fabric (Black) / EPDM Under SSR
Vinyl Wrap = ND
515-102 Fabric (Black) Under SSR Fabric = ND
515-103 Fabric (Black) / EPDM Under SSR Fabric = ND
Vinyl Wrap = ND
515-104 Shingles (Brown) / Shingles (Green) East Entrance Roofing Shingles = ND
515-105 Shingles (Brown) / Shingles (Green) East Entrance Roofing Shingles = ND
-- Flue Insulation W/ Metal Jacket South Wall Assumed Positive 30 LF G F
SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM
Building 515 – Photographs
Building Exterior – Note Chimney “Metalbestos” label on Chimney
Building Interior – Note ACM Floor Tile ACM Floor Tile
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0515
Sample Location Map
J. SMITH
1st Floor
01 02
03 04
06 07
13 14
19 20
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0515
Sample Location Map
J. SMITH
Roof
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0515
ACM Location Map
Asbestos-Containing 12x12 TAN FLOOR TILE with BROWN, WHITE, & PINK SPECKS Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET
Assumed ACM Flue Insulation with Metal Jacket (Extends into Building)
12” x 12” Floor Tile (Tan with Brown, White, & Pink Specks) Covered by Carpet in some areas
1st Floor
J. SMITH
01 02
BUILDING 540
Applies to Buildings: 540 & 550
CAT Code Description: 44220 STORAGE GP INST
Summary of Findings
ACM Present: Yes
ORMs Present: Yes
Explosives Screening Done: No
If Yes, was it present?
Describe:
NA
Construction Details:
Building Size: 2360 SF
Date Constructed: Not Reported
Number of Floors:
(not including Basement)
Basement Present: No
Framing: Wood
Foundation Type: Pier and Beam
Foundation Material: Concrete and Wood
Roof Style: Pitched
Roof Material: Standing Seam Metal
Exterior Wall Composition: Sheet Metal Over Wood
Building Observations:
Current Use: Storage
Building 540 – ACM & ORM Summary
12” x 12” Grey Floor Tile & Mastic (Black) 1400 SF
Transite Panels 250 SF
Asphalt Shingle and Transite Debris Pile 50 SF
Other Regulated Materials (ORMs)
Light Fixtures – Interior & Exterior Ext. 3
Standard Int. 13
4 ft Fluorescent Light Fixtures 8
2 Tubes each Fixture East Section 16
1 Non-PCB Ballasts each Fixture 8
1 PCB Ballasts each Fixture 8
Electrical Panels / Fuse Boxes 4
Exit Signs: Reflective 3
Fire Extinguishers 3
Furnaces East Section 2
Hazardous Waste/ Chemicals
Small Container of Chemicals Paints 50+
Tank: AST North Side 1
Use: Propane Capacity: Unknown
Thermostats On Furnace – East Section 2
Transformers: Pole-Mounted Northwest Corner 1
Other: Grease Trap West End 1
Other: Parts Washers East Section 2
Other: Flammable Cabinets` East Section 3
SF – Square Feet
Building 540 – ACM Sample Inventory
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
540-01 Window Glazing Compound North Side
Window Window Glazing = ND
540-02 Window Glazing Compound South Side
Window Window Glazing = ND
540-03 Sheetrock (Original) East End Wall Drywall Material = ND
540-04 Sheetrock (Original) West End
Ceiling Drywall Material = ND
540-05 Fiberboard East End Wall Fiber Board = ND
540-06 Fiberboard Northwest
Corner Fiber Board = ND
540-07 Interior Door Frame Caulk East End Doors
North Side Caulking = ND
540-08 Interior Door Frame Caulk East End Doors
South Side Caulking = ND
540-09 Sheetrock (New) East Wall West
End
Texture = ND
540-10 Sheetrock (New) North Wall East
End
540-11 Homasite Board West End
Crawlspace Fiber Board = ND
540-12 Homasite Board West End
Crawlspace Fiber Board = ND
540-13 12” x 12” Grey Floor Tile & Mastic (Black)
West End of East Section
Floor Tile = 5% CH Black Mastic = 5%CH
1400 SF D NF1
540-14 12” x 12” Grey Floor Tile & Mastic (Black)
West End of East Section
Floor Tile = 5% CH Black Mastic = 5%CH
1400 SF D NF1
540-101 White Vapor Barrier Under SSR Vinyl Wrap = ND
540-102 White Vapor Barrier Under SSR Vinyl Wrap = ND
-- Transite Panels West End Assumed Positive 250 SF D NF2
Asphalt Shingle and Transite Debris Pile
West End Assumed Positive 50 SF D NF1
SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM
Building 540 – Photographs
Building Exterior Building Interior
ACM 12x12 Grey Floor Tile & Mastic Transite Debris mixed with Shingles
Transite Panels Transite Panels
02-23-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0540
Sample Location Map
J. SMITH
1st Floor
03 05
14 07 08
11 12
02-23-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0540
Sample Location Map
J. SMITH
Roof
No ACM Reported
02-23-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0540
ACM Location Map
J. SMITH
Asbestos-Containing 12x12 GREY FLOOR TILE & MASTIC Assumed Asbestos-Containing TRANSITE PANEL & TRANSITE DEBRIS
Assumed ACM Transite Panels & Transite Debris
ACM Grey Floor Tile
BUILDING 543
Applies to Buildings: 541, 542 & 543
CAT Code Description: 17120 GEN INST BLDG
Summary of Findings
ACM Present: Yes
ORMs Present: Yes
Explosives Screening Done: No
If Yes, was it present?
Describe:
NA
Construction Details:
Building Size: 4720 SF
Date Constructed: Not Reported
Number of Floors:
(not including Basement)
Basement Present: No
Framing: Wood
Foundation Type: Pier and Beam
Foundation Material: Concrete and Wood
Roof Style: Pitched
Roof Material: Shingles
Exterior Wall Composition: Metal on Wood
Building Observations:
Current Use: Occupied – Offices / Classroom
Building 543 – ACM & ORM Summary
Sealer (Black) Chimney 1 SF
Flue Insulation w/ Metal Jacket Chimney 30 LF
Other Regulated Materials (ORMs)
Light Fixtures – Interior & Exterior
Standard 3
4 ft Fluorescent Light Fixtures 15
4 Tubes each Fixture 60
1 Non-PCB Ballasts each Fixture 15
1 PCB Ballasts each Fixture 15
4 ft Fluorescent Light Fixtures 8
2 Tubes each Fixture 16
1 Non-PCB Ballasts each Fixture 8
4 ft Fluorescent Light Fixtures Restroom 2
1 Tubes each Fixture 2
1 Non-PCB Ballasts each Fixture 2
8 ft Fluorescent Light Fixtures 1
2 Tubes each Fixture 2
2 Non-PCB Ballasts each Fixture 2
4 ft Fluorescent Light Fixtures Mechanical Room 2
2 Tubes each Fixture 4
1 PCB Ballasts each Fixture 2
Electrical Panels / Fuse Boxes 4
Emergency Lights with Battery(ies) 6
Exit Signs: Illuminated 8
Fire Extinguishers 7
Furnaces 1
Gas Meters 1
Hot Water Heaters 1
HVAC Units: Window Units 10
Smoke Detectors 14
Thermostats 4
Transformers: Pole-Mounted 1
Water Coolers 1
SF – Square Feet LF – Linear Feet EA – Each
Building 543 – ACM Sample Inventory
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
543-01 Mastic, Plastic Wall Panels Room 5 Yellow Mastic = ND
543-02 Mastic, Plastic Wall Panels Room 5 Yellow = ND
543-03 Wall and Ceiling System Room 7 Ceiling
543-04 Wall and Ceiling System Room 3 Wall
543-05 Cove Base (Gray) and Mastic Room 2
543-06 Cove Base (Gray) and Mastic Room 1
543-07 Stair Tread and Mastic Stairwell Stair Tread = ND
543-08 Stair Tread and Mastic Stairwell
543-09 12” x 12” Floor Tile (Light Gray) and Mastic
Room 2
543-10 12” x 12” Floor Tile (Light Gray) and Mastic
Room 1
543-11 Hangers on HVAC Duct Insulation
Room 3 HVAC Debris = ND
543-12 Hangers on HVAC Duct Insulation
Room 3 HVAC Debris = ND
543-13 Vibration Isolators Room 3 Vibration Isolator = ND
543-14 Vibration Isolators Room 3 Vibration Isolator = ND
543-15 Mastic/Sealer on Fiberglass Pipe Insulation
Room 3 Thermal Insulation = ND
543-16 Mastic/Sealer on Fiberglass Pipe Insulation
Room 3 Thermal Insulation = ND
543-17 Caulk, Window Cover West End Caulking = ND
543-18 Caulk, Window Cover West End Caulking = ND
543-19 12” x 12” Floor Tile (Gray) and Mastic
Room 8
543-20 12” x 12” Floor Tile (Gray) and Mastic
Room 7
543-21 Cove Base (Black) and Mastic Room 7
543-22 Cove Base (Black) and Mastic Room 8
543-23 12” x 12” Ceiling Tile Room 8 Acoustic Tile = ND
543-24 12” x 12” Ceiling Tile Room 7 Acoustic Tile = ND
543-25 2’ x 2’ Ceiling Tile Room 5 Acoustic Tile = ND
543-26 2’ x 2’ Ceiling Tile Room 5 Acoustic Tile = ND
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
543-27 Mastic, Wood Paneling Room 8 Yellow Mastic = ND
543-28 Mastic, Wood Paneling Room 7 Yellow Mastic = ND
543-101 Shingles (Brown) / Tar Paper Roof Roofing Shingles = ND
Tar Papers = ND
543-102 Shingles (Brown) / Tar Paper Roof
543-103 Sealer (Black) Chimney Sealant = 10% Ch 1 SF G NF1
543-104 Sealer (Black) Chimney PS 1 SF G NF1
-- Flue Insulation w/ Metal Jacket Chimney Assumed Positive 30 LF G F
SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM
Building 543 – Photographs
Building Exterior Building Exterior – Note Chimney
Building Interior Roof Sealer at Chimney
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0543
Sample Location Map
J. SMITH
1st Floor
4 5
01, 26
13 12
15 16
17 18
25 02
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
BUILDING 0543
Sample Location Map
J. SMITH
9 10
20 21
Not To Scale
2nd Floor
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
BUILDING 0543
Sample Location Map
J. SMITH
Chimney
Vent
Not To Scale
Roof
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
BUILDING 0543
ACM Location Map
J. SMITH
Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET
Not To Scale
1st Floor
Assumed ACM Flue Insulation with Metal Jacket (Extends into Building)
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
BUILDING 0543
ACM Location Map
J. SMITH
Asbestos-Containing BLACK SEALER Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET
ACM Black Sealer
Chimney
Vent
Not To Scale
Roof
Metal Jacket (Extends Below Roof)
BUILDING 544
Applies to Buildings: 544 Only
CAT Code Description: 14185 CO HGBLDG
Summary of Findings
ACM Present: Yes
ORMs Present: Yes
Explosives Screening Done: No
If Yes, was it present?
Describe:
NA
Construction Details:
Building Size: 2750 SF
Date Constructed: Not Reported
Number of Floors:
(not including Basement)
Basement Present: No
Framing: Wood
Foundation Type: Slab East – Pier and Beam West
Foundation Material: Concrete and Wood
Roof Style: Pitched
Roof Material: Shingles
Exterior Wall Composition: Metal1
Building Observations:
Current Use: Occupied – Gym
Building Condition: Intact
Other: Flue Insulation with Metal Jacket Not Sampled – Assumed
ACM
Building 544 – ACM & ORM Summary
Window Glazing 20 Windows
12” x 12” Tan Floor Tile with Brown and White Streaks & Mastic
1300 SF
Sealer (Black) Chimney / Vents 3 LF
Flue Insulation w/ Metal Jacket Chimney 15LF
Other Regulated Materials (ORMs)
Light Fixtures – Interior & Exterior
Standard 5
4 ft Fluorescent Light Fixtures 1
2 Tubes each Fixture 2
1 Non-PCB Ballasts each Fixture 1
4 ft Fluorescent Light Fixtures Box Lights 26
2 Tubes each Fixture 52
1 PCB Ballasts each Fixture 26
2 ft Fluorescent Light Fixtures Restroom 1
2 Tubes each Fixture 2
1 Non-PCB Ballasts each Fixture 1
Electrical Panels / Fuse Boxes 6
Emergency Lights with Battery(ies) 3
Exit Signs: Reflective 1
Fire Extinguishers 2
Furnaces 1
Gas Meters 1
Hot Water Heaters 1
Thermostats 1
Water Coolers 1
SF – Square Feet
Building 544 – ACM Sample Inventory
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
544-1 Window Glazing East Side Window Glazing = 5%CH 20 Windows G NF2
544-02 Window Glazing North Side PS 20 Windows G NF2
544-03 Mastic, HVAC Duct Insulation Room 5 Thermal Insulation = ND
Paper/Foil = ND
544-04 Mastic, HVAC Duct Insulation Room 5
Paper/Foil = ND
544-05 Vibration Isolators Room 5 Isolator Material = ND
544-06 Vibration Isolators Room 5 Isolator Material = ND
544-07 Wall and Ceiling System Room 5 Drywall Material = ND
544-08 Wall and Ceiling System Room 6
Joint Compound/Texture = ND
544-09 Putty, HVAC Duct Joints Room 5 Putty = ND
544-10 Putty, HVAC Duct Joints Room 5 Putty = ND
544-11 Cove Base and Mastic Room 1
544-12 Cove Base and Mastic Room 3
544-13 Non-skid Strips Room 4 Non-skid Strip = ND Clear Mastic = ND
544-14 Non-skid Strips Room 4 Non-skid Strip = ND Clear Mastic = ND
544-15 12” x 12” Tan Floor Tile with Brown and White Streaks & Mastic
Room 6 Floor Tile = 5% CH
Black Mastic = 5% CH
1300 SF G NF2
544-16 12” x 12” Tan Floor Tile with Brown and White Streaks & Mastic
Room 6 Floor Tile = 5% CH
Black Mastic = 5% CH
1300 SF G NF2
544-101 Shingles (Brown) / Vapor Barrier (Black
Roof
Vapor Barrier = ND
54-102 Shingles (Brown) / Vapor Barrier (Black
Roof
544-103 Sealer (Black) Chimney /
Vents Sealer 1 = 10% CH
Sealer 2 = ND
3 LF G NF1
544-104 Sealer (Black) Chimney /
Vents
PS 3 LF G NF1
-- Flue Insulation w/ Metal Jacket Chimney Assumed Positive 15 LF G F
SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM
Building 544 – Photographs
Building Exterior Window Glazing
Chimney Sealer at Chimney
Building Interior – ACM Tile & Mastic Under Mats ACM Floor Tile & Mastic Under Floor Mats
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0544
Sample Location Map
J. SMITH
1st Floor
04 05 06
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0544
Sample Location Map
J. SMITH
1st Floor
Chimney
Vents
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0544
ACM Location Map
J. SMITH
Asbestos-Containing WINDOW GLAZING Asbestos-Containing TAN FLOOR TILE AND MASTIC
Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET
ACM 12X12 Tan Floor Tile & Mastic (Under Mats)
ACM Window Glazing
1st Floor
Metal Jacket (Extends Above Roof)
09-20-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0544
ACM Location Map
J. SMITH
Asbestos-Containing BLACK SEALER Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET
ACM Black Sealer
1st Floor
Chimney
Vents
Metal Jacket (Extends Below Roof)
BUILDING 545
Applies to Buildings: 545 Only
CAT Code Description: 44220 STORAGE GP INST
Summary of Findings
ACM Present: Yes
ORMs Present: Yes
Explosives Screening Done: No
If Yes, was it present?
Describe:
NA
Construction Details:
Building Size: 2500 SF
Date Constructed: Not Reported
Number of Floors:
(not including Basement)
Basement Present: No
Framing: Wood
Foundation Type: Pier and Beam
Foundation Material: Concrete and Frame
Roof Style: Pitched
Roof Material: Asphalt Shingle
Exterior Wall Composition: Sheet Metal
Building Observations:
Current Use: NCO STX Warehouse
Building 545 – ACM & ORM Summary
12” x 12” Floor Tile (Grey) with Mastic (Black) 1296 SF
Stainless Steel Sink Undercoating (Black) 8 SF
Window Glazing Compound 1280 LF
Sealer (Black) 50 LF
Other Regulated Materials (ORMs)
Light Fixtures – Interior & Exterior
Standard 19
Electrical Panels / Fuse Boxes 4
Emergency Lights with Battery(ies) 2
Fire Extinguishers 12
Gas Meters Regulator Only 1
Hot Water Heaters 2
Hazardous Waste/ Chemicals
Small Container of Chemicals 1 Gallon 2
Building 545 – ACM Sample Inventory
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
545-01 Sheetrock and Joint Compound West End Interior
Partition
545-02 Sheetrock and Joint Compound East End Exterior
Wall
545-03 12” x 12” Floor Tile (Grey) with Mastic (Black)
East End Floor Tile = 3% Ch
Black Mastic = 5% Ch
1296 SF D NF1
545-04 12” x 12” Floor Tile (Grey) with Mastic (Black)
Center PS 1296 SF D NF1
545-05 Stainless Steel Sink Undercoating (Black)
Stainless Steel Sink West End
Sink Undercoating = 3% Ch
8 SF G NF2
545-06 Stainless Steel Sink Undercoating (Black)
Stainless Steel Sink West End
PS 8 SF G NF2
545-07 Window Glazing Compound Exterior Window
East End Window Glazing = ND 1280 LF D NF2
545-08 Window Glazing Compound Exterior Window
Southwest Corner Window Glazing = 2% Ch 1280 LF D NF2
545-09 Clay Tile (Red) with Mortar (Grey)
South Wall Tile = ND
Mortar = ND
545-10 Clay Tile (Red) with Mortar (Grey)
South Wall Tile = ND
545-101 Shingles (Brown) / Tar Paper Roof Roofing Shingles 1 = ND Roofing Shingles 2 = ND
545-102 Shingles (Brown) / Tar Paper Roof Roofing Shingles 1 = ND Roofing Shingles 2 = ND
545-103 Sealer (Black) Vents Sealer = 10% Ch 50 LF G NF1
545-104 Sealer (Black) Vents PS 50 LF G NF1
SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM
Building 545 – Photographs
Building Exterior Building Interior
ACM Sealer on Roof Vents ACM Window Glazing
ACM 12” x 12” Grey Floor Tile & Mastic ACM Sink Undercoating
09-21-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0545
Sample Location Map
J. SMITH
1st Floor
05 06
09-21-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
BUILDING 0545
Sample Location Map
J. SMITH
Roof
Vent
Vent
Vent
Vent
Vent
Vent
Vents
Not To Scale
09-21-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
BUILDING 0545
ACM Location Map
J. SMITH
Asbestos-Containing GREY FLOOR TILE AND MASTIC Asbestos-Containing SINK UNDERCOATING
Asbestos-Containing WINDOW GLAZING COMPOUND
ACM Sink Undercoating
ACM Grey Floor Tile with Mastic
1st Floor
ACM Window Glazing Compound
09-21-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
BUILDING 0545
ACM Location Map
J. SMITH
Asbestos-Containing BLACK SEALER
ACM Black Sealer
Roof
Vent
Vent
Vent
Vent
Vent
Vent
Vents
BUILDING 552
Applies to Buildings: 551, 552, 553 & 571
CAT Code Description: 72122 TRANS UPH AST
Summary of Findings
ACM Present: Yes
ORMs Present: Yes
Explosives Screening Done: No
If Yes, was it present?
Describe:
NA
Construction Details:
Building Size: 4720 SF
Date Constructed: Not Reported
Number of Floors:
(not including Basement)
Basement Present: No
Framing: Wood
Foundation Type: Pier and Beam
Foundation Material: Concrete and Wood
Roof Style: Pitched
Roof Material: Standing Seam Metal
Exterior Wall Composition: Sheet Metal Over Wood
Building Observations:
Current Use: Barracks
Building 552 – ACM & ORM Summary
Transite Window / Door Blanks Door & North and South Windows
175 SF
Fire Doors 26 EA
Other Regulated Materials (ORMs)
Light Fixtures – Interior & Exterior Exterior 3
Standard
Metal Halide, Sodium, etc.
4 ft Fluorescent Light Fixtures 12
1 Tubes each Fixture 12
1 Non-PCB Ballasts each Fixture 12
4 ft Fluorescent Light Fixtures 6
2 Tubes each Fixture 12
2 Non-PCB Ballasts each Fixture 12
Electrical Panels / Fuse Boxes Mechanical Room 4
Emergency Lights with Battery(ies) 6
Exit Signs: Illuminated 6
Fire Extinguishers 4
Furnaces Mechanical Room 2
Gas Meters Northeast Corner 1
Hot Water Heaters Mechanical Room 1
Smoke Detectors 8
Thermostats 2
Water Coolers Fountain Only, Not Cooler 1
SF – Square Feet
Building 552 – ACM Sample Inventory
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
552-01 Transite Window Blank Caulk North Side Caulking = ND
552-02 Transite Window Blank Caulk South Side Caulking 1 = ND
Caulking 2 = ND
552-03 Vibration Isolator (Black) Mechanical Room Isolator Material = ND
552-04 Vibration Isolator (Black) Mechanical Room Isolator Material = ND
552-05 Pipe Insulation (Fiberglass) Sealant
Mechanical Room Paper / Foil Wrap = ND
552-06 Pipe Insulation (Fiberglass) Sealant
Mechanical Room White Mastic = ND
552-07 2’ x 2’ Suspended Ceiling Tile 1st Floor Bathroom Acoustic Tile = ND
552-08 2’ x 2’ Suspended Ceiling Tile 1st Floor Bathroom Acoustic Tile = ND
552-09 12” x 12” Floor Tile (Tan) with Mastic (Yellow)
1st Floor Entrance
- South
552-10 12” x 12” Floor Tile (Tan) with Mastic (Yellow)
1st Floor Entrance
- South
552-11 Vinyl Cove Base (Black) with Mastic (Tan)
1st Floor
552-12
Mastic (Tan)
2nd Floor Laundry
552-13 Stair Tread (Brown) with Mastic (Tan)
Top of Stairs
552-14 Stair Tread (Brown) with Mastic (Tan)
Bottom of Stairs
552-15 Stair Tread Riser (Tan) with Mastic (Tan)
Top of Stairs
552-16 Stair Tread Riser (Tan) with Mastic (Tan)
Bottom of Stairs
552-17 Bathroom Panel Mastic (Tan) 1st Floor Bathroom Tan Mastic = ND
552-18 Bathroom Panel Mastic (Tan) 1st Floor Bathroom Tan Mastic = ND
552-19 12” x 12” Floor Tile (Grey) with Mastic (Brown/Yellow)
1st Floor
552-20
Mastic (Brown/Yellow)
1st Floor
552-21 Sheetrock and Joint Compound 1st Floor
552-22 Sheetrock and Joint Compound Mechanical Room
552-101 Sealer (Grey) Under SSR Edge Sealant=ND
552-102 Sealer (Grey) Under SSR Edge Sealant=ND
552-103 Shingles (Grey) / Tar Paper Under SSR Roofing Shingles=ND
552-104 Shingles (Grey) / Tar Paper Ender SSR Roofing Shingles=ND
-- Transite Window / Door Blanks Door & North and South Windows
Assumed Positive 175 SF G NF2
-- Fire Doors Throughout Assumed Positive 26 EA G F SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM
Building 552 – Photographs
Assumed Transite Panels – Window Blank Assumed Transite Panels – Door Blank
Building Interior Assumed ACM Fire Doors
09-23-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0552
Sample Location Map
J. SMITH
1st Floor
14 16
09-23-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0552
Sample Location Map
J. SMITH
2nd Floor
13 15
09-23-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0552
Sample Location Map
J. SMITH
Roof
Vent
09-23-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0552
ACM Location Map
J. SMITH
Assumed ACM Transite Window & Door Blanks
1st Floor
Assumed Asbestos-Containing TRANSITE WINDOW & DOOR BLANKS Assumed Asbestos-Containing FIRE DOORS
Assumed ACM Fire Doors
09-23-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0552
ACM Location Map
J. SMITH
2nd Floor
Assumed Asbestos-Containing TRANSITE WINDOW & DOOR BLANKS Assumed Asbestos-Containing FIRE DOORS
Assumed ACM Transite Window & Door Blanks
Assumed ACM Fire Doors
BUILDING 560
Applies to Buildings: 560 Only
CAT Code Description: 14185 GO HQBLDG
Summary of Findings
ACM Present:
ORMs Present:
Explosives Screening Done:
If Yes, was it present?
Describe:
Construction Details:
Building Size: 3131 SF
Date Constructed: Not Reported
Number of Floors:
(not including Basement)
One
Basement Present: No
Framing: Wood
Foundation Type: Slab
Foundation Material: Concrete
Roof Style: Pitched
Roof Material: Standing Seam Metal
Exterior Wall Composition: Sheet Metal – CMU Block – Mechanical Room Addition
Building Observations:
Current Use: NCO Academy Storage
Building 560 – ACM & ORM Summary
Sealer (White) on Fiberglass Duct Insulation Furnace Duct 5 SF
Flue Insulation w/ Metal Jacket Chimney 15 LF
Other Regulated Materials (ORMs)
Light Fixtures – Interior & Exterior
Standard 10
Metal Halide, Sodium, etc.
4 ft Fluorescent Light Fixtures 20
4 Tubes each Fixture 80
1 Non-PCB Ballasts each Fixture 20
1 PCB Ballasts each Fixture 20
4 ft Fluorescent Light Fixtures 3
2 Tubes each Fixture 6
1 Non-PCB Ballasts each Fixture 3
Electrical Panels / Fuse Boxes 1
Emergency Lights with Battery(ies) 2
Exit Signs: Illuminated 1
Fire Extinguishers 3
Furnaces 1
Gas Meters North Side 1
Hot Water Heaters Bathroom – East End 1
HVAC Units: Window Units 1
Tank: UST Unknown if Present – Label Indicating Tank Information Observed
Use: Fuel Oil? Capacity: Unknown
Thermostats 1
Transformers: Pole-Mounted Northwest Side 1
SF – Square Feet
Building 560 – ACM Sample Inventory
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
-- Flue Insulation w/ Metal Jacket Chimney Assumed Positive 15 LF G F
560-01 Sheetrock and Joint Compound
560-02 Sheetrock and Joint Compound
560-03 12” x 12” Floor Tile (Beige) and Mastic (Yellow)
Office
560-04 12” x 12” Floor Tile (Beige) and Mastic (Yellow)
Office
560-05 Floor Tile (Grey) with Mastic (Black)
Office Yellow Mastic = ND
560-06 Floor Tile (Grey) with Mastic (Black
Office Yellow Mastic = ND
560-07 Vinyl Cove Base (Grey) with Mastic (Tan)
Office
Cream Mastic = ND
560-08 Vinyl Cove Base (Grey) with Mastic (Tan)
Office
Cream Mastic = ND
560-09 Window Glazing Compound Exterior Window
East End Window Glazing = ND
560-10 Window Glazing Compound Exterior Window
South Side Window Glazing = ND
560-11 Penetration Sealer (Red) Sealant = ND
560-12 Penetration Sealer (Red) Sealant = ND
560-13 Insulation Mastic (Black, Yellow Fiberglass)
Attic Insulation = ND
Paper / Tar Wrap = ND
560-14 Insulation Mastic (Black, Yellow Fiberglass)
Attic Insulation = ND
560-15 CMU Block and Mortar, Mechanical Room
Northwest Corner Mechanical
Room
CMU = ND
560-16 CMU Block and Mortar, Mechanical Room
Northeast Corner Mechanical
Room
CMU = ND
560-17 Vibration Isolator (White) Mechanical
Room Isolator Material = ND
560-18 Vibration Isolator (White) Mechanical
Room Isolator Material = ND
560-19 Sealer (White) on Fiberglass Duct Insulation
Furnace Duct Thermal Insulation = ND
Paper/Foil Wrap = ND White Mastic = 10% CH
25 SF G NF2
560-20 Sealer (White) on Fiberglass Duct Insulation
Furnace Duct PS 25 SF G NF2
560-101 Tar Paper / Vapor Barrier (Black) Under SSR Tar Paper = ND
560-102 Tar Paper / Vapor Barrier (Black) Under SSR Tar Paper = ND
Building 560 – Photographs
Building Exterior Building Exterior – Note Chimney
Furnaces with ACM Mastic/Sealer on Duct Insulation Label indicating possible UST Fuel Oil Tank
Building Interior Building Interior
09-21-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
Not To Scale
BUILDING 0560
Sample Location Map
J. SMITH
1st Floor
04 06 08
Arms Room
Not Accessible
09-21-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
BUILDING 0560
Sample Location Map
J. SMITH
Roof
Vent
Vent
Vent
Vent
Chimney
09-21-2011
FORT DRUM
Pre-Demolition Survey
Figure Drawn
Title:
Checked
Project:
BUILDING 0560
ACM Location Map
J. SMITH
Asbestos-Containing WHITE SEALER ON FIBERGLASS DUCT INSULATION Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET
ACM White Sealer on Fiberglass Duct Insulation
1st Floor
Assumed ACM Flue Insulation with Metal Jacket (Extends Above Roof)
BUILDING 572
Applies to Buildings: 572 & 573
CAT Code Description: 72122 TRANS UPH AST
Summary of Findings
ACM Present: Yes
ORMs Present: Yes
Explosives Screening Done: No
If Yes, was it present?
Describe:
NA
Construction Details:
Building Size: 5310 SF
Date Constructed: Not Reported
Number of Floors:
(not including Basement)
Basement Present: None
Framing: Wood
Foundation Type: Pier and Beam
Foundation Material: Concrete and Wood
Roof Style: Pitched
Roof Material: Asphalt Shingle
Exterior Wall Composition: Sheet Metal Over Wood
Building Observations:
Current Use: Overflow Barracks – NCO Academy
Building 572 – ACM & ORM Summary
Mastic associated with Vinyl Stair Tread 45 SF
Sealer (White) on Staples in Fiberglass Duct Insulation
3 SF
Residual Breaching Packing on Chimney Chimney 4 SF
Black Sealer Chimney 12 LF
Fire Doors Throughout 22 EA
Transite Panels 500 SF
Other Regulated Materials (ORMs)
Light Fixtures – Interior & Exterior
Standard Exterior 3
Metal Halide, Sodium, etc.
8 ft Fluorescent Light Fixtures
2 Tubes each Fixture Shower 1
Non-PCB Ballasts each Fixture
PCB Ballasts each Fixture
4 ft Fluorescent Light Fixtures Mechanical Room 2
2 Tubes each Fixture Interior 47
Non-PCB Ballasts each Fixture
PCB Ballasts each Fixture
2 ft Fluorescent Light Fixtures
1 Tubes each Fixture Bathroom 6
Non-PCB Ballasts each Fixture
PCB Ballasts each Fixture
Electrical Panels / Fuse Boxes Mechanical Room 2
Emergency Lights with Battery(ies) 7
Exit Signs: Illuminated 5
Fire Extinguishers 5
Furnaces Mechanical Room 1
Gas Meters Northwest Corner 1
Hot Water Heaters Mechanical Room 1
Smoke Detectors 32
Thermostats 1
SF – Square Feet
Building 572 – ACM Sample Inventory
Material Description Sample
Location Laboratory Analysis
Material Extent
Condition Friability
572-01 Sheetrock and Joint Compound 1st Floor West
Hallway
572-02 Sheetrock and Joint Compound 2nd Floor West
Hallway
572-03
Leveling Compound (Grey) and Mastic (Black)
1st Floor West Hallway
Floor Tile = ND
Leveling Compound = ND
572-04
Leveling Compound (Grey) and Mastic (Black)
2nd Floor West Hallway
Floor Tile = ND
Leveling Compound = ND
572-05 Transite Wall Paneling in Bathroom with Mastic (Tan)
1st Floor Bathroom Wall
Cement Fiber Board = ND
57…