Fort_Drum_ACM_Report_-_500_Area_Buildings_excerpt.pdf

PDF 1 MB Posted

Attached to
Non-Commissioned Officer (NCO) Academy Complex, Fort Drum, New York
Solicitation number
W912DS-17-R-0001
Issued by

About this file

W912DS-17-R-0001-0005 ACD REPORT

View the file

Other files

File Type Posted
C-751.pdf PDF
W912DS-17-R-0001-AMENDMENT_0012.pdf PDF
CP_NCOA-DMMA-CF.pdf PDF
W912DS-17-R-0001-0011.pdf PDF
W912DS-17-R-0001-AMENDMENT_0010.pdf PDF
W912DS-17-R-0001-0010_ET-602_Card_Access_System.pdf PDF
W912DS-17-R-0001-AMENDMENT_0009.pdf PDF
Plan_Set_-_REV1.pdf PDF
W912DS-17-R-0001-AMENDMENT_0008.pdf PDF
NCOA-STRUCT_Amendment7_31Jan2017.pdf PDF
Appendix_J_-_NOI__100__RTA_NCOA_SWPPP_rev01-31-2017-2.pdf PDF
Amend__7_SPECs_Reissued_02-01-17.pdf PDF
100__NCOA_SWPPP_rev01-31-2017_(No_Appendix).pdf PDF
W912DS-17-R-0001-AMENDMENT_0007.pdf PDF
NCOA_Plumbing_Revised_Dwgs_Amend_7.pdf PDF
100pcnt_LEED_Checklist_20160930.pdf PDF
ADDITIONAL_RFIs_20170126_REV.pdf PDF
NCOA_Civil_Dwgs_Amend_7.pdf PDF
W912DS-17-R-0001-0006.pdf PDF
W912DS-17-R-0001-0006.pdf PDF
W912DS-17-R-0001-AMENDMENT_0005.pdf PDF
Fort_Drum_Lab_Data-_500_Area_Buildings_excerpt.pdf PDF
Copy_of_Asbestos_DataRequest_20160315.pdf PDF
Amend__5_SPECs_Reissued_1-22-17.pdf PDF
Amend__5_Arch_Drawings_Reissued_1-20-17_.pdf PDF
C-GP0001_NCOA_Grading_Plan_bound.dwg DWG drawing
PLAN_SET.pdf PDF
C-GP0001_NCOA_Grading_Plan_converted.dgn —
Amend__5_Civil_drawings_reissued.pdf PDF
Copy_of_Lead_DataRequest_20160315.pdf PDF
1-10-17_Site_Visit_Sign_In_roster.pdf PDF
W912DS-17-R-0001-AMENDMENT_0004.pdf PDF
NCOA_INT_REV1.pdf PDF
W912DS-17-R-0001-AMENDMENT_0003.pdf PDF
NCOA_revCivilSheets_12-29-2016.pdf PDF
Sign_In_Roster_for_NCOA_Site_Visit_20_DEC_2016.pdf PDF
W912DS-17-R-0001-AMENDMENT_0002.pdf PDF
RFI-0001_NCOA_DR-WDs.pdf PDF
W912DS-17-R-0001-0001.pdf PDF
Site_Visit_Map.pdf PDF
RTA_100PCNT_DESIGN_-_SPECS_SUBMISSION.pdf PDF
W912DS-17-R-0001_SOLICITATION_FOR_NCO_ACADEMY_COMPLEX_FORT_DRUM_NEW_YORK.pdf PDF
RTA_100PCNT_DESIGN_-_DRAWINGS_SUBMISSION.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pre-Demolition Survey Report

Fort Drum Military Reservation, New York

Contract Number: W912DY-11-D-0026

Date: January 9, 2012

Prepared for:

U.S. Army Engineering and Support Center Huntsville, Alabama

Prepared By:

Great Southern Engineering, Incorporated 3795 Gordon Terry Parkway Trinity, Alabama 35673 256-350-9754

Executive Summary

Great Southern Engineering, Incorporated (GSE) was contracted by the U.S. Army Engineering and Support Center in Huntsville, Alabama to perform a Pre-Demolition Survey for one hundred ninety four (194) buildings/structures at the Fort Drum in New York during Phase II of the Fort

Drum Pre-Demolition Survey effort. This work was performed under Contract Number

W912DY-11-D-0026. The field portion of the work was completed on November 28, 2011. The following summarizes the project personnel for this installation:

USACE Contact: Mindy Shelton

Site Point of Contact: Rick Nuijens

GSE Principal-in-Charge: Kaye Meeks

GSE Project Manager: Jeff Smith

Asbestos Inspectors: Chris Bradford, Nevin Bradford, Tim Kordek, Jamie Pentland, Joshua Sandberg and Jeff Smith

ORM Inspectors: Chris Bradford, Nevin Bradford, Tim Kordek, Jamie Pentland, Joshua Sandberg and Jeff Smith

Explosives Residue Screening: Not Applicable

This report documents GSE’s work for this task order. Our findings are summarized below:

Asbestos Containing Material (ACM) and other regulated materials (ORMs) were found in various buildings during this investigation.

Screening for the presence of explosives residue was not conducted as part of GSE’s scope of services.

Purpose

The purpose of this task is to complete Pre-Demolition Surveys of the referenced facilities at

Fort Drum Military Reservation to identify significant sources, location and estimated quantities of ACMs and ORMs. ORMs included fluorescent light fixtures, lighted exit signs, smoke detectors, fire extinguishers, transformers, air conditioners and chiller units, thermostats, electric control panels, drinking water fountains, generators, circuit breakers, batteries and battery chargers.

Limitations

The following limitations apply to this survey:

1. The buildings were grouped by CAT Code and square footage. At the direction of

USACE, only one building from each group was surveyed. Buildings that did not fit into the grouping criteria were individually surveyed.

2. GSE initially identified areas where USTs may exist or may have previously existed.

The survey crew was told by Mr. John Ashcraft, Ft. Drum Real Estate, that many of the tanks had been removed and that all of the remaining fuel oil tanks are currently being removed from the Post. The contractor responsible for the removal is to be finished by

September 30, 2011. Therefore, GSE did not provide a complete inventory fuel oil USTs as part of this investigation.

3. GSE attempted to identify all materials, but some may exist that were beyond reasonable access to the inspectors during the site visit. GSE attempted to access crawl spaces, wall cavities, sub-floors, vaults, hidden/concealed conditions, locked rooms or similar areas only if the areas were considered safe and reasonably accessible by field personnel.

4. Materials that were not considered a “suspect asbestos-containing material” were not sampled. These non-suspect materials included silicone, foam rubber, fiberglass, wood, glass, and metal.

5. Older flooring materials (i.e., 9x9 floor tile) were covered by a newer layer of plywood and flooring materials in several buildings. Observations were made in buildings where penetrations previously had been drilled through the floor. This condition may exist in other buildings.

6. Electrical wiring was live at the time of the survey and therefore was not sampled in any building.

Site Activities

Per the direction of USACE, buildings having the same square footage and CAT Codes were grouped together and only one building in each group was surveyed. The results from that building are applied to all buildings in the group. Some materials, such as 9”x9” floor tile, may be assumed to contain asbestos by GSE’s field personnel. If a material is assumed to contain asbestos, then samples were not collected from that material.

GSE conducted the inspections of the buildings to determine the presence of asbestos-containing materials (ACM), other regulated materials (ORM). As directed by the USACE, the asbestos surveys were completed to comply with the federal National Emission Standard for

Hazardous Air Pollutants (NESHAP – 40 CFR 61, Subparts A & M). No ORM samples were collected. ACM samples were collected in accordance with applicable federal regulations and subsequently submitted to a NVLAP-accredited laboratory for testing. Polarized Light

Microscopy (PLM) was the analytical method employed to analyze the samples using positive stop procedures. Positive stop means that once a positive (greater than 1% asbestos) result is obtained, the remaining samples for that material are not analyzed.

The following table provides a list of the buildings included in this task order. The shaded buildings represent groups of buildings with the same CAT CODE and square footage. Only one building from each group was surveyed. The buildings listed in red indicate the buildings that were surveyed from that group. The buildings not shaded indicate buildings that were surveyed individually.

BUILDING NUMBER CATCD BUILDING FUNCTION SF

4752 75052 REC SHELTER 221

4754 75052 REC SHELTER 221

4759 75052 REC SHELTER 221

1388 89120 PLT/UTIL BLDG 296

4779 89120 PLT/UTIL BLDG 296

2260 72350 GARAGE UPH DET 384

4707 72350 GARAGE UPH DET 384

2253 72010 ARMY LODGING 607

2254 72010 ARMY LODGING 607

2255 72010 ARMY LODGING 607

2256 72010 ARMY LODGING 607

2257 72010 ARMY LODGING 607

306* 14185 CO HQBLDG 1,144

561 14185 CO HQBLDG 1,144

562 14185 CO HQBLDG 1,144

4881 14185 CO HQBLDG 1,144

7* 61050 ADMIN GEN PURP 1,144

131 61050 ADMIN GEN PURP 1,144

1001 61050 ADMIN GEN PURP 1,750

1003 61050 ADMIN GEN PURP 1,750

2248 44220 STORAGE GP INST 2,250

4893 44220 STORAGE GP INST 2,250

540 44220 STORAGE GP INST 2,360

550 44220 STORAGE GP INST 2,360

9 61050 ADMIN GEN PURP 2,892

20 61050 ADMIN GEN PURP 2,892

514 17120 GEN INST BLDG 3,663

515 17120 GEN INST BLDG 3,663

1644* 21410 VEH MAINT SHOP 4,166

1174 21410 VEH MAINT SHOP 4,166

1444* 21410 VEH MAINT SHOP 4,238

1255 21410 VEH MAINT SHOP 4,238

541 17120 GEN INST BLDG 4,720

542 17120 GEN INST BLDG 4,720

543 17120 GEN INST BLDG 4,720

10 61050 ADMIN GEN PURP 4,720

11 61050 ADMIN GEN PURP 4,720

45 61050 ADMIN GEN PURP 4,720

46 61050 ADMIN GEN PURP 4,720

122 61050 ADMIN GEN PURP 4,720

141 61050 ADMIN GEN PURP 4,720

441 72111 ENLISTED UPH 4,720

442 72111 ENLISTED UPH 4,720

443 72111 ENLISTED UPH 4,720

444 72111 ENLISTED UPH 4,720

451 72111 ENLISTED UPH 4,720

452 72111 ENLISTED UPH 4,720

453 72111 ENLISTED UPH 4,720

454 72111 ENLISTED UPH 4,720

471 72111 ENLISTED UPH 4,720

472 72111 ENLISTED UPH 4,720

473 72111 ENLISTED UPH 4,720

474 72111 ENLISTED UPH 4,720

551 72122 TRANS UPH AST 4,720

552 72122 TRANS UPH AST 4,720

553 72122 TRANS UPH AST 4,720

571 72122 TRANS UPH AST 4,720

27 55010 HEALTH CLINIC 5,152

28 55010 HEALTH CLINIC 5,152

124 61050 ADMIN GEN PURP 5,310

4848 61050 ADMIN GEN PURP 5,310

4871 61050 ADMIN GEN PURP 5,310

572 72122 TRANS UPH AST 5,310

573 72122 TRANS UPH AST 5,310

4894 61050 ADMIN GEN PURP 6,490

4895 61050 ADMIN GEN PURP 6,490

1172 21410 VEH MAINT SHOP 7,219

1345 21410 VEH MAINT SHOP 7,219

2201 72010 ARMY LODGING 7,670

2202 72010 ARMY LODGING 7,670

2203 72010 ARMY LODGING 7,670

2204 72010 ARMY LODGING 7,670

2205 72010 ARMY LODGING 7,670

2207 72010 ARMY LODGING 7,670

2208 72010 ARMY LODGING 7,670

2210 72010 ARMY LODGING 7,670

2211 72010 ARMY LODGING 7,670

2212 72010 ARMY LODGING 7,670

2213 72010 ARMY LODGING 7,670

2217 72010 ARMY LODGING 7,670

88* 44220 STORAGE GP INST 9,267

65 44220 STORAGE GP INST 9,267

69 44220 STORAGE GP INST 9,267

74 44220 STORAGE GP INST 9,267

75 44220 STORAGE GP INST 9,267

80 44220 STORAGE GP INST 9,267

98 44220 STORAGE GP INST 9,267

4 61050 ADMIN GEN PURP 5,772

15 21845 ADMIN/SHOP DOL 3,742

29 55010 HEALTH CLINIC 4,720

30 14185 CO HQBLDG 26,693

44 21910 ENG/HOUSING MNT 2,910

55 74078 THRIFT SHOP 8,425

68 44220 STORAGE GP INST 9,345

70 44224 ORG STR BLDG 9,267

73 44220 STORAGE GP INST 9,507

78 74055 EXCH WAREHOUSE 10,491

79 44271 HSG FURN STR 10,491

84 21835 REPAIR BAYS DOL 14,606

85 21845 ADMIN/SHOP DOL 2,284

86 89121 HEALTH PLT BLDG 672

87 44220 STORAGE GP INST 360

91 21910 ENG/HOUSING MNT 22,815

92 74060 BREAK/LUNCH RM 3,108

93 21925 ENGR MAINT FAC 18,240

97 73032 PICKUP POINT 14,008

101 61050 ADMIN GEN PURP 2,305

120 61050 ADMIN GEN PURP 2,488

121 61050 ADMIN GEN PURP 4,876

126 14184 BN HQ BLDG TI 5,310

128 13181 TERM EQP FAC 700

129 13185 PRINT PLANT 3,696

130 61050 ADMIN GEN PURP 2,588

132 44224 ORG STR BLDG 1,144

140 61075 COURTROOM 3,253

148 74085 PVT/ORG CLUB 4,720

191 61050 ADMIN GEN PURP 2,096

198 21910 ENG/HOUSING MNT 8,940

313 17115 BAND TRAIN BLDG 3,663

503 76010 MUSEUM 2,284

513 76011 MUSEUM SPT BLDG 1,726

544 14185 CO HQBLDG 2,750

545 44220 STORAGE GP INST 2,500

560 14185 CO HQBLDG 3,131

574 72210 DINING FACILITY 3,007

1002 61050 ADMIN GEN PURP 3,108

1030 14129 TNG AIDS CTR 12,753

1123 21910 ENG/HOUSING MNT 8,221

1124 61050 ADMIN GEN PURP 12,954

1125 44223 ARMS STORAGE‐BN 4,932

1131 44220 STORAGE GP INST 7,219

1132 21910 ENG/HOUSING MNT 7,795

1141 21910 ENG/HOUSING MNT 7,219

1142 21910 ENG/HOUSING MNT 8,179

1143 21910 ENG/HOUSING MNT 3,108

1151 44220 STORAGE GP INST 13,024

1162 44220 STORAGE GP INST 992

1176 44224 ORG STR BLDG 379

1275 44220 STORAGE GP INST 1,634

1454 21410 VEH MAINT SHOP 6,566

1555 21406 VEH MAINTTI 4,166

1699 84141 PUMP STAAT POT 354

1734 44220 STORAGE GP INST 8,580

2045 89121 HEAT PLT BLDG 750

2046 13320 NAV BLDG, AIR 420

2047 89144 WTR SUP BLD NP 990

2049 14112 AVN UNIT OPS 4,137

2140 12450 MOGAS STR UNGD 23,240

2150 21910 ENG/HOUSING MNT 11,531

2162 21870 MNT STORAGE DOL 355

2166 89120 PLT/UTIL BLDG 3,393

2190 74068 RECREATION CTR 6,396

2209 72410 UOQ MILITARY 7,670

2220 17119 ORG CLASSROOM 6,805

2226 61050 ADMIN GEN PURP 1,976

2227 61050 ADMIN GEN PURP 2,250

2251 72010 ARMY LODGING 1,220

2252 72010 ARMY LODGING 969

2258 72010 ARMY LODGING 460

2259 72010 ARMY LODGING 672

2300 74050 EXCHANGE BRANCH 29,260

2312 14161 EMERG OPNS CNTR 4,129

2360 17138 LIMIT USE INST 27,295

2365 44220 STORAGE GP INST 1,350

2379 89120 PLT/UTIL BLDG 150

2507 17120 GEN INST BLDG 3,851

2509 61050 ADMIN GEN PURP 5,482

2552 44220 STORAGE GP INST 9,000

2707 14113 ACCESS CNT FAC 130

2803 44220 STORAGE GP INST 860

2808 74085 PVT/ORG CLUB 2,040

3829 21410 VEH MAINT SHOP 2,506

3894 44220 STORAGE GP INST 1,250

3895 17138 LIMIT USE INST 1,750

3897 17119 ORG CLASSROOM 7,849

3898 17119 ORG CLASSROOM 2,740

4000 61050 ADMIN GEN PURP 12,767

4001 44222 STR SHED GP INS 4,800

4003 21910 ENG/HOUSING MNT 7,360

4004 21910 ENG/HOUSING MNT 15,584

4012 14180 SCALE HOUSE 704

4705 75052 REC SHELTER 600

4753 75052 REC SHELTER 375

4801 74085 PVT/ORG CLUB 5,310

4808 14183 BN HQ BLDG 5,310

4814 21415 COMP ITEM REP 2,592

4818 61050 ADMIN GEN PURP 1,250

4828 44224 ORG STR BLDG 1,250

4836 76010 MUSEUM 5,310

4838 61050 ADMIN GEN PURP 2,715

4839 61050 ADMIN GEN PURP 2,282

4840 17119 ORG CLASSROOM 2,500

4849 17123 RG SPT FAC 2,250

4850 14185 CO HQBLDG 2,592

4884 61050 ADMIN GEN PURP 4,465

4890 44220 STORAGE GP INST 2,395

6000 21410 VEH MAINT SHOP 30,588

6001 44220 STORAGE GP INST 7,540

6004 44228 HAZ MAT STR INS 400

*Building surveyed during Phase 1

BUILDING DETAILS

BUILDING 306

Applies to Buildings: 306**, 561, 562, 4881

** Bldg. 306 was completed during the Phase 1 Survey

CAT Code Description: 14185 CO HQ BLDG

Summary of Findings

ACM Present: Yes

ORMs Present: Yes

Explosives Screening Done: No

If Yes, was it present?

Describe:

NA

Construction Details:

Building Size: 1,144 SF

Date Constructed: Not Reported

Number of Floors:

(not including Basement)

Basement Present: No

Framing: Wood

Foundation Type: Pier and Beam

Foundation Material: Concrete and Wood

Roof Style: Pitched

Roof Material: Standing Seam Metal

Exterior Wall Composition: Sheet Metal over Wood

Building Observations:

Current Use: Vacant

Building Condition: Intact

Other:

Building 306 – ACM & ORM Summary

Material Description Notes Quantity

Asbestos-Containing Materials (ACMs)

Black Sealer 9LF

Flue Insulation w/ Metal Jacket Chimney 1 Chimney

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior

Standard

Metal Halide, Sodium, etc. 2

4 ft Fluorescent Light Fixtures Throughout 10

4 Tubes each Fixture 40

1 Non-PCB Ballasts each Fixture 10

PCB Ballasts each Fixture

Electrical Panels / Fuse Boxes 2

Emergency Lights with Battery(ies) 2

Exit Signs: Illuminated 2

Furnaces 1

Gas Meters 1

HVAC Units: Small Units 1

Thermostats 1 SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM EA = Each Cr = Crocidolite SD = Significantly Damaged NF2 = Category II Non-Friable ACM ND = None Detected PS = Positive Stop

Building 306 – ACM Sample Inventory Sample Number

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

306-01 Sheetrock and Joint Compound North Wall Drywall Material – ND Joint Compound - ND

306-02 Sheetrock and Joint Compound South Wall

Joint Compound - ND

306-03 2’ x 4’ Suspended Ceiling Tile East End Acoustic Tile - ND

306-04 2’ x 4’ Suspended Ceiling Tile West End Acoustic Tile - ND

306-05 Vinyl Cove Base (Grey) and Mastic

West End Cove Base – ND

Yellow Mastic - ND

306-06 Vinyl Cove Base (Grey) and Mastic

North Wall

306-07 Carpet Mastic (Yellow) West End Floor Tile – ND

306-08 Carpet Mastic (Yellow) East End

306-09 Insulation Mastic (Paper Faced, Yellow Fiberglass)

North Wall Exterior

Thermal Insulation – ND Paper – ND

Black Mastic - ND

306-10 Insulation Mastic (Paper Faced, Yellow Fiberglass)

South Wall Exterior

Thermal Insulation – ND Paper – ND

Black Mastic - ND

306-11 12” x 12” Floor Tile (Green) and Mastic

West End

306-12 12” x 12” Floor Tile (Green) and Mastic

East End

306-13 12” x 12” Floor Tile (White) and Mastic

West End

306-14 12” x 12” Floor Tile (White) and Mastic

East End

306-15 Cork Board Mastic (Yellow) SW End Yellow Mastic - ND

306-16 Cork Board Mastic (Yellow) SW End Yellow Mastic - ND

306-17 Vinyl Cove Base (Brown) with Mastic (Yellow)

East End Vestibule

306-18 Vinyl Cove Base (Brown) with Mastic (Yellow)

East End Vestibule

306-19 Vibration Cloth (Black) Furnace

Mechanical Room

Isolator Material - ND

306-20 Vibration Cloth (Black) Furnace

Mechanical Room

Isolator Material - ND

306-21 Sheetrock North Wall

Center

Texture - ND

306-22 Sheetrock North Wall

Center

Texture - ND

-- Flue Insulation w/ Metal Jacket Chimney Assumed Positive 1 Chimney G F

306-101 Tar Paper Under Metal

Roof Tar Paper=ND

306-102 Tar Paper Under Metal

Roof Tar Paper=ND

306-103 Sealer (Black) Chimney Sealant – 5% Ch 9 LF G NF1

Number

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

306-104 Sealer (Black) Chimney PS 9 LF G NF1

306-105 Asphalt Shingle (Brown) Chimney Roofing Shingle - ND

306-106 Asphalt Shingle (Brown) Chimney Roofing Shingle - ND

SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM

Building 306 – Photographs

Building Exterior - Note Chimney

Roof Chimney with Black Sealer

S. HEMMING

September 7, 2011

FORT DRUM

Pre-Demolition Survey

FigureDrawn

Title:

Checked

Project:

Not To Scale

BUILDING 306

Sample Location Map

S. MCCUTCHEON

September 7, 2011

FORT DRUM

Pre-Demolition Survey

FigureDrawn

Title:

Checked

Project:

Not To Scale

BUILDING 306

Sample Location Map

VENT

VENT

CHIMNEY

ROOF

September 7, 2011

S. MCCUTCHEON

FORT DRUM

Pre-Demolition Survey

BUILDING 306

ACM Location Map

FigureDrawn

Title:

Checked

Project:

Asbestos-Containing BLACK ROOF SEALER

Not To Scale

VENT

VENT

CHIMNEY

ROOF

ACM Black Roof Sealer

September 7, 2011

S. MCCUTCHEON

FORT DRUM

Pre-Demolition Survey

BUILDING 306

ACM Location Map

FigureDrawn

Title:

Checked

Project:

Presumed Asbestos-Containing DOUBLE METAL WALL CHIMNEY

Not To Scale

VENT

VENT

CHIMNEY

ROOF

Presumed ACM Double Metal Wall Chimney

BUILDING 513

Applies to Buildings: 513 Only

CAT Code Description: 76011 MESEUM SPT BLDG

Summary of Findings

ACM Present: Yes

ORMs Present: Yes

Explosives Screening Done: No

If Yes, was it present?

Describe:

NA

Construction Details:

Building Size: 1726 SF

Date Constructed: Not Reported

Number of Floors:

(not including Basement)

Basement Present: No

Framing: Wood

Foundation Type: Pier and Beam

Foundation Material: Concrete and Wood

Roof Style: Pitched

Roof Material: Standing Seam Metal

Exterior Wall Composition: Sheet metal Over Wood

Building Observations:

Current Use: NCOA Chief of Training Offices

Building 513 – ACM & ORM Summary

Exterior Window Glazing Compound 675 LF

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior

Standard 3

4 ft Fluorescent Light Fixtures 15

2 Tubes each Fixture Throughout 30

1 Non-PCB Ballasts each Fixture 15

1 ft Fluorescent Light Fixtures 2

1 Tubes each Fixture Bathroom 2

1 Non-PCB Ballasts each Fixture 2

Electrical Panels / Fuse Boxes 3

Emergency Lights with Battery(ies) 1

Exit Signs: Illuminated 2

Fire Extinguishers 1

Furnaces 1

Gas Meters 1

Hot Water Heaters 1

HVAC Units: Window Units 1

Smoke Detectors 4

Thermostats 2

SF – Square Feet LF – Linear Feet EA – Each

Building 513 – ACM Sample Inventory

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

513-01 Electrical Penetration Sealer (Red)

Mechanical Room Sealer = ND

513-02 Electrical Penetration Sealer (Red)

Mechanical Room Sealer = ND

513-03 Vibration Isolators Mechanical Room Isolator Material = ND

513-04 Vibration Isolators Mechanical Room Isolator Material = ND

513-05 End Cap Sealer (White) on Fiberglass Pipe Insulator

Mechanical Room Thermal Insulation = ND Paper/Foil Wrap = ND

White Mastic = ND

513-06 End Cap Sealer (White) on Fiberglass Pipe Insulator

Mechanical Room Thermal Insulation = ND

513-07 Sheetrock and Joint Compound Southwest Office Drywall Material = ND Joint Compound = ND

513-08 Sheetrock and Joint Compound Mechanical Room

513-09 Vinyl Core Base (Black) with Mastic (Tan)

Northwest Storage Cove Base = ND Tan Mastic = ND

513-10 Vinyl Core Base (Black) with Mastic (Tan)

Southwest Office

513-11 12” x 12” Floor Tile (Brown) with Mastic (Black)

Southwest Office Floor Tile = ND

Black Mastic = ND

513-12 12” x 12” Floor Tile (Brown) with Mastic (Black)

Southwest Office

513-13 Insulation Mastic (Black) Attic Access Thermal Insulation = ND Paper/Tar Wrap = ND

513-14 Insulation Mastic (Black) Attic Access

Paper/Tar Wrap = ND

513-15 Wall Panel Mastic (White) Northwest Storage White Mastic = ND

513-16 Wall Panel Mastic (White) Northwest Storage White Mastic = ND

513-17 Exterior Window Glazing Compound

West Side Window

Glazing = 2% Ch 675 LF G NF2

513-18 Exterior Window Glazing Compound

South Side Window

PS 675 LF G NF2

513-19 Wainscoting Mastic (Tan) North Side Entry

Way Tan Mastic = ND

513-20 Wainscoting Mastic (Tan) Latrine Tan Mastic = ND

513-101 Glue Down EPDM / Isocyanurate Insulation

East Shed Rubber Membrane = ND Paper/Foil Facing = ND Foam Insulation = ND

513-102 Glue Down EPDM / Isocyanurate Insulation

East Shed Rubber Membrane = ND Paper/Foil Facing = ND Foam Insulation = ND

513-103 Fabric (Black) / EPDM Under SSR Fabric = ND

Membrane = ND Tar = ND

513-104 Fabric (Black) / EPDM Under SSR

Membrane = ND Tar = ND

Building 513 – Photographs

Building Exterior Building Exterior

Window Glazing Window Glazing

11/15/2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0513

Sample Location Map

J. SMITH

1st Floor

09 11

16 15

11/15/2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0513

Sample Location Map

J. SMITH

Roof

103 104

No ACM Reported

11/15/2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0513

ACM Location Map

J. SMITH

Asbestos-Containing WINDOW GLAZING

ACM Window Glazing 1st Floor

BUILDING 515

Applies to Buildings: 514 & 515

CAT Code Description: 17120 GEN INST BLDG

Summary of Findings

ACM Present: Yes

ORMs Present: Yes

Explosives Screening Done: No

If Yes, was it present?

Describe:

NA

Construction Details:

Building Size: 3663 SF

Date Constructed: Not Reported

Number of Floors:

(not including Basement)

Basement Present: No

Framing: Wood

Foundation Type: Pier and Beam

Foundation Material: Concrete and Wood

Roof Style: Pitched

Roof Material: Metal

Exterior Wall Composition: Metal

Building Observations:

Current Use: Occupied – Offices and Training

Building 515– ACM & ORM Summary

12” x 12” Floor Tile (Tan with Brown, White, and Pink Specks)

Exposed and under carpet 3400 SF

Flue Insulation W/ Metal Jacket 30 LF

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior

Standard 4

4 ft Fluorescent Light Fixtures 33

4 Tubes each Fixture 132

1 Non-PCB Ballasts each Fixture 33

1 PCB Ballasts each Fixture 33

Electrical Panels / Fuse Boxes 3

Emergency Lights with Battery(ies)

Exit Signs: Illuminated 2

Exit Signs: Reflective

Fire Extinguishers 2

Furnaces 1

Gas Meters 1

Hot Water Heaters 1

HVAC Units: Window Units 3

Thermostats 3

Water Coolers 1

SF – Square Feet

Building 515 – ACM Sample Inventory

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

515-01 Window Glazing Southwest

Corner Window Glazing = ND

515-02 Window Glazing East Corner Window Glazing = ND

515-03 Wall and Ceiling System Room 2

515-04 Wall and Ceiling System Room 1

515-05 Vibration Isolators Room 2 Isolator Material = ND

515-06 Vibration Isolators Room 2 Isolator Material = ND

515-07 Putty, HVAC Duct Joints Room 2 Putty = ND

515-08 Putty, HVAC Duct Joints Room 2 Putty = ND

515-09 Mastic, Pipe Insulation with Paper Cover

Room 2 Thermal Insulation = ND Paper Foil Wrap = ND

515-10 Mastic, Pipe Insulation with Paper Cover

Room 2 Thermal Insulation = ND Paper Foil Wrap = ND

515-11 12” x 12” Floor Tile (Tan w/ Brown, White, and Pink Specks) & Mastic

Room 4 Floor Tile = 3% Ch Black Mastic = ND

3400 SF G NF2

515-12 12” x 12” Floor Tile (Tan w/ Brown, White, and Pink Specks) & Mastic

Room 10 Floor Tile = 3% Ch Black Mastic = ND

3400 SF G NF2

515-13 12” x 12” Floor Tile (Beige with Brown Mottles) and Mastic, Patch

Room 3

515-14 12” x 12” Floor Tile (Beige with Brown Mottles) and Mastic, Patch

Room 3

515-15 Sink Undercoating Room 1 Sink Undercoating = ND

515-16 Sink Undercoating Room 1 Sink Undercoating = ND

515-17 2’ x 4’ Ceiling Tile Room 5 Acoustic Tile = ND

515-18 2’ x 4’ Ceiling Tile Room 7 Acoustic Tile = ND

515-19 Carpet (Maroon) and Mastic Room 7 Carpet = ND

Yellow Mastic = ND

515-20 Carpet (Maroon) and Mastic Room 7 Carpet = ND

515-101 Fabric (Black) / EPDM Under SSR

Vinyl Wrap = ND

515-102 Fabric (Black) Under SSR Fabric = ND

515-103 Fabric (Black) / EPDM Under SSR Fabric = ND

Vinyl Wrap = ND

515-104 Shingles (Brown) / Shingles (Green) East Entrance Roofing Shingles = ND

515-105 Shingles (Brown) / Shingles (Green) East Entrance Roofing Shingles = ND

-- Flue Insulation W/ Metal Jacket South Wall Assumed Positive 30 LF G F

SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM

Building 515 – Photographs

Building Exterior – Note Chimney “Metalbestos” label on Chimney

Building Interior – Note ACM Floor Tile ACM Floor Tile

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0515

Sample Location Map

J. SMITH

1st Floor

01 02

03 04

06 07

13 14

19 20

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0515

Sample Location Map

J. SMITH

Roof

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0515

ACM Location Map

Asbestos-Containing 12x12 TAN FLOOR TILE with BROWN, WHITE, & PINK SPECKS Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET

Assumed ACM Flue Insulation with Metal Jacket (Extends into Building)

12” x 12” Floor Tile (Tan with Brown, White, & Pink Specks) Covered by Carpet in some areas

1st Floor

J. SMITH

01 02

BUILDING 540

Applies to Buildings: 540 & 550

CAT Code Description: 44220 STORAGE GP INST

Summary of Findings

ACM Present: Yes

ORMs Present: Yes

Explosives Screening Done: No

If Yes, was it present?

Describe:

NA

Construction Details:

Building Size: 2360 SF

Date Constructed: Not Reported

Number of Floors:

(not including Basement)

Basement Present: No

Framing: Wood

Foundation Type: Pier and Beam

Foundation Material: Concrete and Wood

Roof Style: Pitched

Roof Material: Standing Seam Metal

Exterior Wall Composition: Sheet Metal Over Wood

Building Observations:

Current Use: Storage

Building 540 – ACM & ORM Summary

12” x 12” Grey Floor Tile & Mastic (Black) 1400 SF

Transite Panels 250 SF

Asphalt Shingle and Transite Debris Pile 50 SF

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior Ext. 3

Standard Int. 13

4 ft Fluorescent Light Fixtures 8

2 Tubes each Fixture East Section 16

1 Non-PCB Ballasts each Fixture 8

1 PCB Ballasts each Fixture 8

Electrical Panels / Fuse Boxes 4

Exit Signs: Reflective 3

Fire Extinguishers 3

Furnaces East Section 2

Hazardous Waste/ Chemicals

Small Container of Chemicals Paints 50+

Tank: AST North Side 1

Use: Propane Capacity: Unknown

Thermostats On Furnace – East Section 2

Transformers: Pole-Mounted Northwest Corner 1

Other: Grease Trap West End 1

Other: Parts Washers East Section 2

Other: Flammable Cabinets` East Section 3

SF – Square Feet

Building 540 – ACM Sample Inventory

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

540-01 Window Glazing Compound North Side

Window Window Glazing = ND

540-02 Window Glazing Compound South Side

Window Window Glazing = ND

540-03 Sheetrock (Original) East End Wall Drywall Material = ND

540-04 Sheetrock (Original) West End

Ceiling Drywall Material = ND

540-05 Fiberboard East End Wall Fiber Board = ND

540-06 Fiberboard Northwest

Corner Fiber Board = ND

540-07 Interior Door Frame Caulk East End Doors

North Side Caulking = ND

540-08 Interior Door Frame Caulk East End Doors

South Side Caulking = ND

540-09 Sheetrock (New) East Wall West

End

Texture = ND

540-10 Sheetrock (New) North Wall East

End

540-11 Homasite Board West End

Crawlspace Fiber Board = ND

540-12 Homasite Board West End

Crawlspace Fiber Board = ND

540-13 12” x 12” Grey Floor Tile & Mastic (Black)

West End of East Section

Floor Tile = 5% CH Black Mastic = 5%CH

1400 SF D NF1

540-14 12” x 12” Grey Floor Tile & Mastic (Black)

West End of East Section

Floor Tile = 5% CH Black Mastic = 5%CH

1400 SF D NF1

540-101 White Vapor Barrier Under SSR Vinyl Wrap = ND

540-102 White Vapor Barrier Under SSR Vinyl Wrap = ND

-- Transite Panels West End Assumed Positive 250 SF D NF2

Asphalt Shingle and Transite Debris Pile

West End Assumed Positive 50 SF D NF1

SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM

Building 540 – Photographs

Building Exterior Building Interior

ACM 12x12 Grey Floor Tile & Mastic Transite Debris mixed with Shingles

Transite Panels Transite Panels

02-23-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0540

Sample Location Map

J. SMITH

1st Floor

03 05

14 07 08

11 12

02-23-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0540

Sample Location Map

J. SMITH

Roof

No ACM Reported

02-23-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0540

ACM Location Map

J. SMITH

Asbestos-Containing 12x12 GREY FLOOR TILE & MASTIC Assumed Asbestos-Containing TRANSITE PANEL & TRANSITE DEBRIS

Assumed ACM Transite Panels & Transite Debris

ACM Grey Floor Tile

BUILDING 543

Applies to Buildings: 541, 542 & 543

CAT Code Description: 17120 GEN INST BLDG

Summary of Findings

ACM Present: Yes

ORMs Present: Yes

Explosives Screening Done: No

If Yes, was it present?

Describe:

NA

Construction Details:

Building Size: 4720 SF

Date Constructed: Not Reported

Number of Floors:

(not including Basement)

Basement Present: No

Framing: Wood

Foundation Type: Pier and Beam

Foundation Material: Concrete and Wood

Roof Style: Pitched

Roof Material: Shingles

Exterior Wall Composition: Metal on Wood

Building Observations:

Current Use: Occupied – Offices / Classroom

Building 543 – ACM & ORM Summary

Sealer (Black) Chimney 1 SF

Flue Insulation w/ Metal Jacket Chimney 30 LF

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior

Standard 3

4 ft Fluorescent Light Fixtures 15

4 Tubes each Fixture 60

1 Non-PCB Ballasts each Fixture 15

1 PCB Ballasts each Fixture 15

4 ft Fluorescent Light Fixtures 8

2 Tubes each Fixture 16

1 Non-PCB Ballasts each Fixture 8

4 ft Fluorescent Light Fixtures Restroom 2

1 Tubes each Fixture 2

1 Non-PCB Ballasts each Fixture 2

8 ft Fluorescent Light Fixtures 1

2 Tubes each Fixture 2

2 Non-PCB Ballasts each Fixture 2

4 ft Fluorescent Light Fixtures Mechanical Room 2

2 Tubes each Fixture 4

1 PCB Ballasts each Fixture 2

Electrical Panels / Fuse Boxes 4

Emergency Lights with Battery(ies) 6

Exit Signs: Illuminated 8

Fire Extinguishers 7

Furnaces 1

Gas Meters 1

Hot Water Heaters 1

HVAC Units: Window Units 10

Smoke Detectors 14

Thermostats 4

Transformers: Pole-Mounted 1

Water Coolers 1

SF – Square Feet LF – Linear Feet EA – Each

Building 543 – ACM Sample Inventory

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

543-01 Mastic, Plastic Wall Panels Room 5 Yellow Mastic = ND

543-02 Mastic, Plastic Wall Panels Room 5 Yellow = ND

543-03 Wall and Ceiling System Room 7 Ceiling

543-04 Wall and Ceiling System Room 3 Wall

543-05 Cove Base (Gray) and Mastic Room 2

543-06 Cove Base (Gray) and Mastic Room 1

543-07 Stair Tread and Mastic Stairwell Stair Tread = ND

543-08 Stair Tread and Mastic Stairwell

543-09 12” x 12” Floor Tile (Light Gray) and Mastic

Room 2

543-10 12” x 12” Floor Tile (Light Gray) and Mastic

Room 1

543-11 Hangers on HVAC Duct Insulation

Room 3 HVAC Debris = ND

543-12 Hangers on HVAC Duct Insulation

Room 3 HVAC Debris = ND

543-13 Vibration Isolators Room 3 Vibration Isolator = ND

543-14 Vibration Isolators Room 3 Vibration Isolator = ND

543-15 Mastic/Sealer on Fiberglass Pipe Insulation

Room 3 Thermal Insulation = ND

543-16 Mastic/Sealer on Fiberglass Pipe Insulation

Room 3 Thermal Insulation = ND

543-17 Caulk, Window Cover West End Caulking = ND

543-18 Caulk, Window Cover West End Caulking = ND

543-19 12” x 12” Floor Tile (Gray) and Mastic

Room 8

543-20 12” x 12” Floor Tile (Gray) and Mastic

Room 7

543-21 Cove Base (Black) and Mastic Room 7

543-22 Cove Base (Black) and Mastic Room 8

543-23 12” x 12” Ceiling Tile Room 8 Acoustic Tile = ND

543-24 12” x 12” Ceiling Tile Room 7 Acoustic Tile = ND

543-25 2’ x 2’ Ceiling Tile Room 5 Acoustic Tile = ND

543-26 2’ x 2’ Ceiling Tile Room 5 Acoustic Tile = ND

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

543-27 Mastic, Wood Paneling Room 8 Yellow Mastic = ND

543-28 Mastic, Wood Paneling Room 7 Yellow Mastic = ND

543-101 Shingles (Brown) / Tar Paper Roof Roofing Shingles = ND

Tar Papers = ND

543-102 Shingles (Brown) / Tar Paper Roof

543-103 Sealer (Black) Chimney Sealant = 10% Ch 1 SF G NF1

543-104 Sealer (Black) Chimney PS 1 SF G NF1

-- Flue Insulation w/ Metal Jacket Chimney Assumed Positive 30 LF G F

SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM

Building 543 – Photographs

Building Exterior Building Exterior – Note Chimney

Building Interior Roof Sealer at Chimney

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0543

Sample Location Map

J. SMITH

1st Floor

4 5

01, 26

13 12

15 16

17 18

25 02

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

BUILDING 0543

Sample Location Map

J. SMITH

9 10

20 21

Not To Scale

2nd Floor

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

BUILDING 0543

Sample Location Map

J. SMITH

Chimney

Vent

Not To Scale

Roof

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

BUILDING 0543

ACM Location Map

J. SMITH

Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET

Not To Scale

1st Floor

Assumed ACM Flue Insulation with Metal Jacket (Extends into Building)

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

BUILDING 0543

ACM Location Map

J. SMITH

Asbestos-Containing BLACK SEALER Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET

ACM Black Sealer

Chimney

Vent

Not To Scale

Roof

Metal Jacket (Extends Below Roof)

BUILDING 544

Applies to Buildings: 544 Only

CAT Code Description: 14185 CO HGBLDG

Summary of Findings

ACM Present: Yes

ORMs Present: Yes

Explosives Screening Done: No

If Yes, was it present?

Describe:

NA

Construction Details:

Building Size: 2750 SF

Date Constructed: Not Reported

Number of Floors:

(not including Basement)

Basement Present: No

Framing: Wood

Foundation Type: Slab East – Pier and Beam West

Foundation Material: Concrete and Wood

Roof Style: Pitched

Roof Material: Shingles

Exterior Wall Composition: Metal1

Building Observations:

Current Use: Occupied – Gym

Building Condition: Intact

Other: Flue Insulation with Metal Jacket Not Sampled – Assumed

ACM

Building 544 – ACM & ORM Summary

Window Glazing 20 Windows

12” x 12” Tan Floor Tile with Brown and White Streaks & Mastic

1300 SF

Sealer (Black) Chimney / Vents 3 LF

Flue Insulation w/ Metal Jacket Chimney 15LF

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior

Standard 5

4 ft Fluorescent Light Fixtures 1

2 Tubes each Fixture 2

1 Non-PCB Ballasts each Fixture 1

4 ft Fluorescent Light Fixtures Box Lights 26

2 Tubes each Fixture 52

1 PCB Ballasts each Fixture 26

2 ft Fluorescent Light Fixtures Restroom 1

2 Tubes each Fixture 2

1 Non-PCB Ballasts each Fixture 1

Electrical Panels / Fuse Boxes 6

Emergency Lights with Battery(ies) 3

Exit Signs: Reflective 1

Fire Extinguishers 2

Furnaces 1

Gas Meters 1

Hot Water Heaters 1

Thermostats 1

Water Coolers 1

SF – Square Feet

Building 544 – ACM Sample Inventory

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

544-1 Window Glazing East Side Window Glazing = 5%CH 20 Windows G NF2

544-02 Window Glazing North Side PS 20 Windows G NF2

544-03 Mastic, HVAC Duct Insulation Room 5 Thermal Insulation = ND

Paper/Foil = ND

544-04 Mastic, HVAC Duct Insulation Room 5

Paper/Foil = ND

544-05 Vibration Isolators Room 5 Isolator Material = ND

544-06 Vibration Isolators Room 5 Isolator Material = ND

544-07 Wall and Ceiling System Room 5 Drywall Material = ND

544-08 Wall and Ceiling System Room 6

Joint Compound/Texture = ND

544-09 Putty, HVAC Duct Joints Room 5 Putty = ND

544-10 Putty, HVAC Duct Joints Room 5 Putty = ND

544-11 Cove Base and Mastic Room 1

544-12 Cove Base and Mastic Room 3

544-13 Non-skid Strips Room 4 Non-skid Strip = ND Clear Mastic = ND

544-14 Non-skid Strips Room 4 Non-skid Strip = ND Clear Mastic = ND

544-15 12” x 12” Tan Floor Tile with Brown and White Streaks & Mastic

Room 6 Floor Tile = 5% CH

Black Mastic = 5% CH

1300 SF G NF2

544-16 12” x 12” Tan Floor Tile with Brown and White Streaks & Mastic

Room 6 Floor Tile = 5% CH

Black Mastic = 5% CH

1300 SF G NF2

544-101 Shingles (Brown) / Vapor Barrier (Black

Roof

Vapor Barrier = ND

54-102 Shingles (Brown) / Vapor Barrier (Black

Roof

544-103 Sealer (Black) Chimney /

Vents Sealer 1 = 10% CH

Sealer 2 = ND

3 LF G NF1

544-104 Sealer (Black) Chimney /

Vents

PS 3 LF G NF1

-- Flue Insulation w/ Metal Jacket Chimney Assumed Positive 15 LF G F

SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM

Building 544 – Photographs

Building Exterior Window Glazing

Chimney Sealer at Chimney

Building Interior – ACM Tile & Mastic Under Mats ACM Floor Tile & Mastic Under Floor Mats

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0544

Sample Location Map

J. SMITH

1st Floor

04 05 06

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0544

Sample Location Map

J. SMITH

1st Floor

Chimney

Vents

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0544

ACM Location Map

J. SMITH

Asbestos-Containing WINDOW GLAZING Asbestos-Containing TAN FLOOR TILE AND MASTIC

Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET

ACM 12X12 Tan Floor Tile & Mastic (Under Mats)

ACM Window Glazing

1st Floor

Metal Jacket (Extends Above Roof)

09-20-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0544

ACM Location Map

J. SMITH

Asbestos-Containing BLACK SEALER Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET

ACM Black Sealer

1st Floor

Chimney

Vents

Metal Jacket (Extends Below Roof)

BUILDING 545

Applies to Buildings: 545 Only

CAT Code Description: 44220 STORAGE GP INST

Summary of Findings

ACM Present: Yes

ORMs Present: Yes

Explosives Screening Done: No

If Yes, was it present?

Describe:

NA

Construction Details:

Building Size: 2500 SF

Date Constructed: Not Reported

Number of Floors:

(not including Basement)

Basement Present: No

Framing: Wood

Foundation Type: Pier and Beam

Foundation Material: Concrete and Frame

Roof Style: Pitched

Roof Material: Asphalt Shingle

Exterior Wall Composition: Sheet Metal

Building Observations:

Current Use: NCO STX Warehouse

Building 545 – ACM & ORM Summary

12” x 12” Floor Tile (Grey) with Mastic (Black) 1296 SF

Stainless Steel Sink Undercoating (Black) 8 SF

Window Glazing Compound 1280 LF

Sealer (Black) 50 LF

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior

Standard 19

Electrical Panels / Fuse Boxes 4

Emergency Lights with Battery(ies) 2

Fire Extinguishers 12

Gas Meters Regulator Only 1

Hot Water Heaters 2

Hazardous Waste/ Chemicals

Small Container of Chemicals 1 Gallon 2

Building 545 – ACM Sample Inventory

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

545-01 Sheetrock and Joint Compound West End Interior

Partition

545-02 Sheetrock and Joint Compound East End Exterior

Wall

545-03 12” x 12” Floor Tile (Grey) with Mastic (Black)

East End Floor Tile = 3% Ch

Black Mastic = 5% Ch

1296 SF D NF1

545-04 12” x 12” Floor Tile (Grey) with Mastic (Black)

Center PS 1296 SF D NF1

545-05 Stainless Steel Sink Undercoating (Black)

Stainless Steel Sink West End

Sink Undercoating = 3% Ch

8 SF G NF2

545-06 Stainless Steel Sink Undercoating (Black)

Stainless Steel Sink West End

PS 8 SF G NF2

545-07 Window Glazing Compound Exterior Window

East End Window Glazing = ND 1280 LF D NF2

545-08 Window Glazing Compound Exterior Window

Southwest Corner Window Glazing = 2% Ch 1280 LF D NF2

545-09 Clay Tile (Red) with Mortar (Grey)

South Wall Tile = ND

Mortar = ND

545-10 Clay Tile (Red) with Mortar (Grey)

South Wall Tile = ND

545-101 Shingles (Brown) / Tar Paper Roof Roofing Shingles 1 = ND Roofing Shingles 2 = ND

545-102 Shingles (Brown) / Tar Paper Roof Roofing Shingles 1 = ND Roofing Shingles 2 = ND

545-103 Sealer (Black) Vents Sealer = 10% Ch 50 LF G NF1

545-104 Sealer (Black) Vents PS 50 LF G NF1

SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM

Building 545 – Photographs

Building Exterior Building Interior

ACM Sealer on Roof Vents ACM Window Glazing

ACM 12” x 12” Grey Floor Tile & Mastic ACM Sink Undercoating

09-21-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0545

Sample Location Map

J. SMITH

1st Floor

05 06

09-21-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

BUILDING 0545

Sample Location Map

J. SMITH

Roof

Vent

Vent

Vent

Vent

Vent

Vent

Vents

Not To Scale

09-21-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

BUILDING 0545

ACM Location Map

J. SMITH

Asbestos-Containing GREY FLOOR TILE AND MASTIC Asbestos-Containing SINK UNDERCOATING

Asbestos-Containing WINDOW GLAZING COMPOUND

ACM Sink Undercoating

ACM Grey Floor Tile with Mastic

1st Floor

ACM Window Glazing Compound

09-21-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

BUILDING 0545

ACM Location Map

J. SMITH

Asbestos-Containing BLACK SEALER

ACM Black Sealer

Roof

Vent

Vent

Vent

Vent

Vent

Vent

Vents

BUILDING 552

Applies to Buildings: 551, 552, 553 & 571

CAT Code Description: 72122 TRANS UPH AST

Summary of Findings

ACM Present: Yes

ORMs Present: Yes

Explosives Screening Done: No

If Yes, was it present?

Describe:

NA

Construction Details:

Building Size: 4720 SF

Date Constructed: Not Reported

Number of Floors:

(not including Basement)

Basement Present: No

Framing: Wood

Foundation Type: Pier and Beam

Foundation Material: Concrete and Wood

Roof Style: Pitched

Roof Material: Standing Seam Metal

Exterior Wall Composition: Sheet Metal Over Wood

Building Observations:

Current Use: Barracks

Building 552 – ACM & ORM Summary

Transite Window / Door Blanks Door & North and South Windows

175 SF

Fire Doors 26 EA

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior Exterior 3

Standard

Metal Halide, Sodium, etc.

4 ft Fluorescent Light Fixtures 12

1 Tubes each Fixture 12

1 Non-PCB Ballasts each Fixture 12

4 ft Fluorescent Light Fixtures 6

2 Tubes each Fixture 12

2 Non-PCB Ballasts each Fixture 12

Electrical Panels / Fuse Boxes Mechanical Room 4

Emergency Lights with Battery(ies) 6

Exit Signs: Illuminated 6

Fire Extinguishers 4

Furnaces Mechanical Room 2

Gas Meters Northeast Corner 1

Hot Water Heaters Mechanical Room 1

Smoke Detectors 8

Thermostats 2

Water Coolers Fountain Only, Not Cooler 1

SF – Square Feet

Building 552 – ACM Sample Inventory

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

552-01 Transite Window Blank Caulk North Side Caulking = ND

552-02 Transite Window Blank Caulk South Side Caulking 1 = ND

Caulking 2 = ND

552-03 Vibration Isolator (Black) Mechanical Room Isolator Material = ND

552-04 Vibration Isolator (Black) Mechanical Room Isolator Material = ND

552-05 Pipe Insulation (Fiberglass) Sealant

Mechanical Room Paper / Foil Wrap = ND

552-06 Pipe Insulation (Fiberglass) Sealant

Mechanical Room White Mastic = ND

552-07 2’ x 2’ Suspended Ceiling Tile 1st Floor Bathroom Acoustic Tile = ND

552-08 2’ x 2’ Suspended Ceiling Tile 1st Floor Bathroom Acoustic Tile = ND

552-09 12” x 12” Floor Tile (Tan) with Mastic (Yellow)

1st Floor Entrance

- South

552-10 12” x 12” Floor Tile (Tan) with Mastic (Yellow)

1st Floor Entrance

- South

552-11 Vinyl Cove Base (Black) with Mastic (Tan)

1st Floor

552-12

Mastic (Tan)

2nd Floor Laundry

552-13 Stair Tread (Brown) with Mastic (Tan)

Top of Stairs

552-14 Stair Tread (Brown) with Mastic (Tan)

Bottom of Stairs

552-15 Stair Tread Riser (Tan) with Mastic (Tan)

Top of Stairs

552-16 Stair Tread Riser (Tan) with Mastic (Tan)

Bottom of Stairs

552-17 Bathroom Panel Mastic (Tan) 1st Floor Bathroom Tan Mastic = ND

552-18 Bathroom Panel Mastic (Tan) 1st Floor Bathroom Tan Mastic = ND

552-19 12” x 12” Floor Tile (Grey) with Mastic (Brown/Yellow)

1st Floor

552-20

Mastic (Brown/Yellow)

1st Floor

552-21 Sheetrock and Joint Compound 1st Floor

552-22 Sheetrock and Joint Compound Mechanical Room

552-101 Sealer (Grey) Under SSR Edge Sealant=ND

552-102 Sealer (Grey) Under SSR Edge Sealant=ND

552-103 Shingles (Grey) / Tar Paper Under SSR Roofing Shingles=ND

552-104 Shingles (Grey) / Tar Paper Ender SSR Roofing Shingles=ND

-- Transite Window / Door Blanks Door & North and South Windows

Assumed Positive 175 SF G NF2

-- Fire Doors Throughout Assumed Positive 26 EA G F SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM

Building 552 – Photographs

Assumed Transite Panels – Window Blank Assumed Transite Panels – Door Blank

Building Interior Assumed ACM Fire Doors

09-23-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0552

Sample Location Map

J. SMITH

1st Floor

14 16

09-23-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0552

Sample Location Map

J. SMITH

2nd Floor

13 15

09-23-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0552

Sample Location Map

J. SMITH

Roof

Vent

09-23-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0552

ACM Location Map

J. SMITH

Assumed ACM Transite Window & Door Blanks

1st Floor

Assumed Asbestos-Containing TRANSITE WINDOW & DOOR BLANKS Assumed Asbestos-Containing FIRE DOORS

Assumed ACM Fire Doors

09-23-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0552

ACM Location Map

J. SMITH

2nd Floor

Assumed Asbestos-Containing TRANSITE WINDOW & DOOR BLANKS Assumed Asbestos-Containing FIRE DOORS

Assumed ACM Transite Window & Door Blanks

Assumed ACM Fire Doors

BUILDING 560

Applies to Buildings: 560 Only

CAT Code Description: 14185 GO HQBLDG

Summary of Findings

ACM Present:

ORMs Present:

Explosives Screening Done:

If Yes, was it present?

Describe:

Construction Details:

Building Size: 3131 SF

Date Constructed: Not Reported

Number of Floors:

(not including Basement)

One

Basement Present: No

Framing: Wood

Foundation Type: Slab

Foundation Material: Concrete

Roof Style: Pitched

Roof Material: Standing Seam Metal

Exterior Wall Composition: Sheet Metal – CMU Block – Mechanical Room Addition

Building Observations:

Current Use: NCO Academy Storage

Building 560 – ACM & ORM Summary

Sealer (White) on Fiberglass Duct Insulation Furnace Duct 5 SF

Flue Insulation w/ Metal Jacket Chimney 15 LF

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior

Standard 10

Metal Halide, Sodium, etc.

4 ft Fluorescent Light Fixtures 20

4 Tubes each Fixture 80

1 Non-PCB Ballasts each Fixture 20

1 PCB Ballasts each Fixture 20

4 ft Fluorescent Light Fixtures 3

2 Tubes each Fixture 6

1 Non-PCB Ballasts each Fixture 3

Electrical Panels / Fuse Boxes 1

Emergency Lights with Battery(ies) 2

Exit Signs: Illuminated 1

Fire Extinguishers 3

Furnaces 1

Gas Meters North Side 1

Hot Water Heaters Bathroom – East End 1

HVAC Units: Window Units 1

Tank: UST Unknown if Present – Label Indicating Tank Information Observed

Use: Fuel Oil? Capacity: Unknown

Thermostats 1

Transformers: Pole-Mounted Northwest Side 1

SF – Square Feet

Building 560 – ACM Sample Inventory

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

-- Flue Insulation w/ Metal Jacket Chimney Assumed Positive 15 LF G F

560-01 Sheetrock and Joint Compound

560-02 Sheetrock and Joint Compound

560-03 12” x 12” Floor Tile (Beige) and Mastic (Yellow)

Office

560-04 12” x 12” Floor Tile (Beige) and Mastic (Yellow)

Office

560-05 Floor Tile (Grey) with Mastic (Black)

Office Yellow Mastic = ND

560-06 Floor Tile (Grey) with Mastic (Black

Office Yellow Mastic = ND

560-07 Vinyl Cove Base (Grey) with Mastic (Tan)

Office

Cream Mastic = ND

560-08 Vinyl Cove Base (Grey) with Mastic (Tan)

Office

Cream Mastic = ND

560-09 Window Glazing Compound Exterior Window

East End Window Glazing = ND

560-10 Window Glazing Compound Exterior Window

South Side Window Glazing = ND

560-11 Penetration Sealer (Red) Sealant = ND

560-12 Penetration Sealer (Red) Sealant = ND

560-13 Insulation Mastic (Black, Yellow Fiberglass)

Attic Insulation = ND

Paper / Tar Wrap = ND

560-14 Insulation Mastic (Black, Yellow Fiberglass)

Attic Insulation = ND

560-15 CMU Block and Mortar, Mechanical Room

Northwest Corner Mechanical

Room

CMU = ND

560-16 CMU Block and Mortar, Mechanical Room

Northeast Corner Mechanical

Room

CMU = ND

560-17 Vibration Isolator (White) Mechanical

Room Isolator Material = ND

560-18 Vibration Isolator (White) Mechanical

Room Isolator Material = ND

560-19 Sealer (White) on Fiberglass Duct Insulation

Furnace Duct Thermal Insulation = ND

Paper/Foil Wrap = ND White Mastic = 10% CH

25 SF G NF2

560-20 Sealer (White) on Fiberglass Duct Insulation

Furnace Duct PS 25 SF G NF2

560-101 Tar Paper / Vapor Barrier (Black) Under SSR Tar Paper = ND

560-102 Tar Paper / Vapor Barrier (Black) Under SSR Tar Paper = ND

Building 560 – Photographs

Building Exterior Building Exterior – Note Chimney

Furnaces with ACM Mastic/Sealer on Duct Insulation Label indicating possible UST Fuel Oil Tank

Building Interior Building Interior

09-21-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 0560

Sample Location Map

J. SMITH

1st Floor

04 06 08

Arms Room

Not Accessible

09-21-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

BUILDING 0560

Sample Location Map

J. SMITH

Roof

Vent

Vent

Vent

Vent

Chimney

09-21-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

BUILDING 0560

ACM Location Map

J. SMITH

Asbestos-Containing WHITE SEALER ON FIBERGLASS DUCT INSULATION Assumed Asbestos-Containing FLUE INSULATION WITH METAL JACKET

ACM White Sealer on Fiberglass Duct Insulation

1st Floor

Assumed ACM Flue Insulation with Metal Jacket (Extends Above Roof)

BUILDING 572

Applies to Buildings: 572 & 573

CAT Code Description: 72122 TRANS UPH AST

Summary of Findings

ACM Present: Yes

ORMs Present: Yes

Explosives Screening Done: No

If Yes, was it present?

Describe:

NA

Construction Details:

Building Size: 5310 SF

Date Constructed: Not Reported

Number of Floors:

(not including Basement)

Basement Present: None

Framing: Wood

Foundation Type: Pier and Beam

Foundation Material: Concrete and Wood

Roof Style: Pitched

Roof Material: Asphalt Shingle

Exterior Wall Composition: Sheet Metal Over Wood

Building Observations:

Current Use: Overflow Barracks – NCO Academy

Building 572 – ACM & ORM Summary

Mastic associated with Vinyl Stair Tread 45 SF

Sealer (White) on Staples in Fiberglass Duct Insulation

3 SF

Residual Breaching Packing on Chimney Chimney 4 SF

Black Sealer Chimney 12 LF

Fire Doors Throughout 22 EA

Transite Panels 500 SF

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior

Standard Exterior 3

Metal Halide, Sodium, etc.

8 ft Fluorescent Light Fixtures

2 Tubes each Fixture Shower 1

Non-PCB Ballasts each Fixture

PCB Ballasts each Fixture

4 ft Fluorescent Light Fixtures Mechanical Room 2

2 Tubes each Fixture Interior 47

Non-PCB Ballasts each Fixture

PCB Ballasts each Fixture

2 ft Fluorescent Light Fixtures

1 Tubes each Fixture Bathroom 6

Non-PCB Ballasts each Fixture

PCB Ballasts each Fixture

Electrical Panels / Fuse Boxes Mechanical Room 2

Emergency Lights with Battery(ies) 7

Exit Signs: Illuminated 5

Fire Extinguishers 5

Furnaces Mechanical Room 1

Gas Meters Northwest Corner 1

Hot Water Heaters Mechanical Room 1

Smoke Detectors 32

Thermostats 1

SF – Square Feet

Building 572 – ACM Sample Inventory

Material Description Sample

Location Laboratory Analysis

Material Extent

Condition Friability

572-01 Sheetrock and Joint Compound 1st Floor West

Hallway

572-02 Sheetrock and Joint Compound 2nd Floor West

Hallway

572-03

Leveling Compound (Grey) and Mastic (Black)

1st Floor West Hallway

Floor Tile = ND

Leveling Compound = ND

572-04

Leveling Compound (Grey) and Mastic (Black)

2nd Floor West Hallway

Floor Tile = ND

Leveling Compound = ND

572-05 Transite Wall Paneling in Bathroom with Mastic (Tan)

1st Floor Bathroom Wall

Cement Fiber Board = ND

57…