UP
AUDITORIUM
TRAINING AREA
MECH
COMM
BARRACK
BARRACK
BARRACK
BARRACK
LAUNDRY
CONF
TRAINING OFFICE
ADMIN SUITE
VESTIBULE
LOBBY
BARRACK
OFFICE
RR
COMMANDANT
OFFICE
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
OFFICE
COPY CNTR
OFFICE
TA-50 STORAGE
TEST ROOM
RECORDS ROOM
STAIR
CLOSET
STAFF BREAK
ROOM
BARRACK ACCESS
ELEC
FINISH LEGEND
CPT-1
PORC-1
SC
SC/WM
VCT-1,2,3,4
VCT-2
WM/VCT
ELEV
SCRUB AREA
STAIR A
ARMS ROOM
INT. STAIR
EMR
M CADRE LOCKERS
M SHOWER/
LOCKERS
W SHOWERS/
LOCKERS
W CADRE LOCKERS
SUPPLY
JAN CL / STO
KEY PLAN
PLAN NORTH
0' 8' 16' 32' 64'
SCALE: 1/16" = 1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
1/3/2017 1:24:02 PM
C:\Users\foretb\Documents\1160170_NCOA_INTERIORS_CENTRAL_R15_Bforet.rvt
I-101
F
IR
S T
F L O
O R
F
IN
IS
H
K E
Y P
L A
N
N C
O A
C A
D E
M Y
C O
M P
L E
X
N E
W Y
O R
K N
E W
Y O
R K
N
Y
F
E D
E R
A L P
L A
Z A
R O
O M
N E
W Y
O R
K N
Y
-0
B F
C B
B F
M D
O C
T O
B E
R
W D
S -1
-R
-0
W -1
-D
-0
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
G
E N
E R
A L R
E V
IS
IO
N S
D E
C
SCALE: 1/16" = 1'-0"B2
FIRST FLOOR FINISH KEY PLAN
DN
DN
CLASSROOM
MECH
STAIR A
CLASSROOM
OFFICE
OFFICE
OFFICE
OFFICE
CLASSROOM
CLASSROOM
CLASSROOM
238M RR
INSTRUCTIONAL
ACCESS
CLASSROOM
OFFICE
CLASSROOM
OFFICE
OFFICE
OFFICE
OFFICE
CLASSROOM
LEARNING
RESOURCE CENTER
OFFICE
OFFICE
INSTRUCTIONAL
ACCESS
OFFICE
OFFICE
OFFICE
COMM
ELEV
STO / J.C.
ELEC
STUDENT BREAK
AREA
BARRACK
BARRACK
BARRACK
BARRACK
BARRACK
F RR
STAIR B
FINISH LEGEND
CPT-1
PORC-1
SC
VCT-1,2,3,4
VCT-2
JAN CLOSET
INT. STAIR
STORAGE
213A
KEY PLAN
PLAN NORTH
0' 8' 16' 32' 64'
SCALE: 1/16" = 1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
1/3/2017 1:24:06 PM
C:\Users\foretb\Documents\1160170_NCOA_INTERIORS_CENTRAL_R15_Bforet.rvt
I-102
S E
C O
N D
F L O
O R
F
IN
IS
H
K E
Y P
L A
N
N C
O A
C A
D E
M Y
C O
M P
L E
X
N E
W Y
O R
K N
E W
Y O
R K
N
Y
F
E D
E R
A L P
L A
Z A
R O
O M
N E
W Y
O R
K N
Y
-0
B F
C B
B F
M D
O C
T O
B E
R
W D
S -1
-R
-0
W -1
-D
-0
SCALE: 1/16" = 1'-0"B2
SECOND FLOOR FINISH KEY PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
G
E N
E R
A L R
E V
IS
IO
N S
D E
C
PORCB
SS-2 SS-2
PORCB
OPEN TO
LOCKERS
AREA
MG MG MG MG MG MG
SD SDSDSD
MG
PTDWR PTDWR
URINALS
PORCB
SS-2
PTDWR
SD
PORC-2
PORCB
PORCB 3
MG
TSCD
SND
SD
I-201D1
C1
C2
M SHOWER/
LOCKERS
PTDWR
DTL DTL DTL DTL DTL
DTL DTL DTL DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL DTL DTL DTLDTL DTL DTL
DTL
DTL
DTL
DTL
DTL DTL
DTL
DTL
DTL
DTL
DTL DTL DTL DTL DTL DTL DTL
DTL
DTL
DTL
DTL DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTLTP
TP
TP
TP
TP TP TP
TP
TP
TP
TP
TP
TP
TP
TP
TP-B
TP
TP
/4
I-201
D5
2' - 6"
F RR
4' - 9"
2' - 1"
/2
SS-2
PORCB
PORCB
PORC-2
" 2
EHDEHD
PTDWR
MG
SS-2
PORCB
"2
ACP ACOUSTIC CEILING PANEL
CG CORNER GUARD
CPT CARPET
DTL DOUBLE TIER LOCKER
EXP EXPOSED
GR GROUT
GWB GYPSUM WALL BOARD
PT PAINT
PL PLASTIC LAMINATE
PORC PORCELAIN TILE
PORCB PORCELAIN TILE BULLNOSE
RB RUBBER BASE
RT RUBBER TILE
SC SEALED CONCRETE
SS SOLID SURFACE
TP TOILET PARTITION
TS TRANSITION STRIP
VCT VINYL COMPOSITION TILE
WM WALK-OFF MAT
MATERIALS & FINISHES
ABBREVIATIONS LIST
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
1/3/2017 1:24:12 PM
C:\Users\foretb\Documents\1160170_NCOA_INTERIORS_CENTRAL_R15_Bforet.rvt
I-201
E N
L A
R G
E D
P L
A N
S A
N D
I N
T E
R
IO
R E
L E
V A
T
IO
N S
N C
O A
C A
D E
M Y
C O
M P
L E
X
N E
W Y
O R
K N
E W
Y O
R K
N
Y
F
E D
E R
A L P
L A
Z A
R O
O M
N E
W Y
O R
K N
Y
-0
B F
C B
B F
M D
O C
T O
B E
R
W D
S -1
-R
-0
W -1
-D
-0
SCALE: 3/8" = 1'-0"C2
145-M SHOWER LOCKERS
SCALE: 3/8" = 1'-0"C1
145-M SHOWER LOCKERS
SCALE: 3/8" = 1'-0"D1
145-M SHOWER LOCKERS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
G
E N
E R
A L R
E V
IS
IO
N S
D E
C
SCALE: 3/8" = 1'-0"D5
PUBLIC RESTROOM
SCALE: 1/4" = 1'-0"A1
ENLARGED 145-M SHOWER / LOCKERS
SCALE: 1/4" = 1'-0"D4
ENLARGED PUBLIC RR
SCALE: 1/4" = 1'-0"A4
ENLARGED 205-F RESTROOM
SCALE: 3/8" = 1'-0"C4
205-F RESTROOM
SCALE: 3/8" = 1'-0"D3
205-F RESTROOM
0' 2' 4' 8' 16'
SCALE: 1/4" = 1'-0"
0' 4' 8'1'
SCALE: 3/8" = 1'-0"
6'
PLAN NORTH
FILLER 11' - 9"
FILLER
W1830W3630 W3330 W3630W1830
B1834B3634B3334B3634B1834
PL-1
PL-1
PL-2
11' - 11 3/4"
I-202C2
I-202
C1
I-202 D1
W SHOWERS/
LOCKERS
M CADRE LOCKERS
W CADRE LOCKERS
DTL
DTL
DTL
DTL
DTL
DTL DTL DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTL
DTLDTLDTLDTLDTL
DTL
DTL
DTL
DTLDTL
DTL
DTL
DTL
DTLDTLDTL
SH1 SH1
DTL
DTL
DTL
DTL
I-202 C4D3
PORC-2
PORCB
PORCB
DTL DTL DTL DTL DTL DTL DTL DTL
PORCB
SS-2
MGMGMG
SD SD
PORCB
SS-2
DTL DTL DTL DTL DTL
MG MG MG MG
SD SD
PORCB
PORC-2
PORCB
SS-2
MG MG MG MG
SD SD
EHD EHD
PTDWR PTDWR
PORCB
PORC-2
11' - 11 3/4"
ACP ACOUSTIC CEILING PANEL
CG CORNER GUARD
CPT CARPET
DTL DOUBLE TIER LOCKER
EXP EXPOSED
GR GROUT
GWB GYPSUM WALL BOARD
PT PAINT
PL PLASTIC LAMINATE
PORC PORCELAIN TILE
PORCB PORCELAIN TILE BULLNOSE
RB RUBBER BASE
RT RUBBER TILE
SC SEALED CONCRETE
SS SOLID SURFACE
TP TOILET PARTITION
TS TRANSITION STRIP
VCT VINYL COMPOSITION TILE
WM WALK-OFF MAT
MATERIALS & FINISHES
ABBREVIATIONS LIST
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
1/3/2017 1:24:20 PM
C:\Users\foretb\Documents\1160170_NCOA_INTERIORS_CENTRAL_R15_Bforet.rvt
I-202
E N
L A
R G
E D
P L
A N
S A
N D
I N
T E
R
IO
R E
L E
V A
T
IO
N S
N C
O A
C A
D E
M Y
C O
M P
L E
X
N E
W Y
O R
K N
E W
Y O
R K
N
Y
F
E D
E R
A L P
L A
Z A
R O
O M
N E
W Y
O R
K N
Y
-0
B F
C B
B F
M D
O C
T O
B E
R
W D
S -1
-R
-0
W -1
-D
-0
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
G
E N
E R
A L R
E V
IS
IO
N S
D E
C
SCALE: 1/4" = 1'-0"A4
135-COPY CENTER
SCALE: 1/4" = 1'-0"A1
ENLARGED 146-W SHOWERS AND 146/147-CADRES
SCALE: 1/4" = 1'-0"A3
ENLARGED 239-M RESTROOM
SCALE: 3/8" = 1'-0"D1
147-M CADRE LOCKERS
SCALE: 3/8" = 1'-0"C1
147-M CADRE LOCKERS
SCALE: 3/8" = 1'-0"C2
146-W SHOWER LOCKERS
SCALE: 3/8" = 1'-0"D3
239-M RESTROOM
SCALE: 3/8" = 1'-0"C4
239-M RESTROOM
SCALE: 1/4" = 1'-0"B4
ENLARGED 135-COPY CTR
0' 4' 8'1'
SCALE: 3/8" = 1'-0"
6'
0' 2' 4' 8' 16'
SCALE: 1/4" = 1'-0"
PLAN NORTH
E1
E1
SB3334 B2734 B2134
W2130 W2712W3312 W3315 W2712 W2130 W3312
B2734B2134
2' - 10" 10' - 9" 2' - 10"
E2E2
FILLER FILLER
N.I.C. N.I.C.
N.I.C. N.I.C.
16' - 5"
N.I.C
CM1
2' - 10" 11' - 3"
FILLER
W2430 W2712 W3315 W2712 W2430
B2734 B2434SB3334B2734B2434
E2 E2
FILLER
W3312
E1 CM1
N.I.C.
N.I.C. N.I.C.
N.I.C.
14' - 4"
FILLER
I-203
A1
E1
E2 E2
CM1
11' - 6"2' - 10"
14' - 4"
N.I.C. N.I.C.
N.I.C. E1E1 2
2' - 10" 10' - 9" 2' - 10"
E2 E2
16' - 5"
I-203
A3
CM1
N.I.C.
N.I.C. N.I.C.
W3630 W3630 W3630
B3634B3634B3634
FILLER 6' - 0"
FILLER FILLER
3' - 0"
FILLER
W3030 W3330
B3334B3034
FILLER 5' - 3" FILLER
5' - 7"
SUPPORT BRACKET SS-2
E3 E3 E3
LAUNDRY
FOLDING TABLEN.I.C. N.I.C. N.I.C.
5' - 0"
I-203
D3
E4 E4 E4
E3E3E3
TC3
VINYL TRANSITION
STRIP
VCT TILE;
AS SCHEDULED
CONCRETE SLAB
CARPET; AS
SCHEDULED
*FEATHER FLOOR WITH LEVELING COMPOUND TO ALLOW SMOOTH
TRANSITION BETWEEN BOTH FLOORING SURFACES. CONTRACTOR
TO ENSURE SMOOTH TRANSITION BETWEEN MATERIALS.
*FEATHER FLOOR WITH LEVELING COMPOUND TO ALLOW SMOOTH
TRANSITION BETWEEN BOTH FLOORING SURFACES. CONTRACTOR
TO ENSURE SMOOTH TRANSITION BETWEEN MATERIALS.
CONCRETE SLAB
STAINLESS STEEL
SCHLUTER STRIP
PORCELAIN TILE;
AS SCHEDULED
VINYL TILE;
AS SCHEDULED
*FEATHER FLOOR WITH LEVELING COMPOUND TO ALLOW SMOOTH
TRANSITION BETWEEN BOTH FLOORING SURFACES. CONTRACTOR
TO ENSURE SMOOTH TRANSITION BETWEEN MATERIALS.
CONCRETE SLAB
PORCELAIN TILE;
AS SCHEDULED
STAINLESS STEEL
SCHLUTER STRIP
CARPET; AS
SCHEDULED
CONCRETE SLAB
TOP OF SEALED
CONCRETE
VINYL FLOORING;
AS SCHEDULED
1/8" TILE REDUCER STRIP
BEVELED EDGE (192Z BY
FLEXCO; COLOR:TBD)
FOR RESILIENT FLOORING
1"
CARPET TO VCT/VINYL
PORCELAIN TO VCT/VINYL
CARPET TO PORCELAIN TILE
VCT/VINYL TO SEALED CONCRETE
GENERAL NOTES:
1. ALL DASHED EQUIPMENT IS NOT INCLUDED IN CONTRACT
(N.I.C.) AND IS PART OF THE FF&E PACKAGE.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
1/3/2017 1:24:24 PM
C:\Users\foretb\Documents\1160170_NCOA_INTERIORS_CENTRAL_R15_Bforet.rvt
I-203
E N
L A
R G
E D
P L A
N S
IN
T E
R
IO
R E
L E
V A
T
IO
N S
T
R A
N S
IT
IO
N D
E T
A
IL
S
N C
O A
C A
D E
M Y
C O
M P
L E
X
N E
W Y
O R
K N
E W
Y O
R K
N
Y
F
E D
E R
A L P
L A
Z A
R O
O M
N E
W Y
O R
K N
Y
-0
B F
C B
B F
M D
O C
T O
B E
R
W D
S -1
-R
-0
W -1
-D
-0
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
G
E N
E R
A L R
E V
IS
IO
N S
D E
C
SCALE: 3/8" = 1'-0"A3
212-STUDENT BREAK AREA
SCALE: 3/8" = 1'-0"A1
136-STAFF BREAK ROOM
SCALE: 3/8" = 1'-0"B1
136-ENLARGED STAFF BREAK ROOM
SCALE: 3/8" = 1'-0"B3
ENLARGED 212-STUDENT BREAK AREA
0' 4' 8'1'
SCALE: 3/8" = 1'-0"
6'
SCALE: 3/8" = 1'-0"C1
CORRIDOR STORAGE - WIDE
SCALE: 3/8" = 1'-0"C3
TYPICAL CORRIDOR STORAGE
PLAN NORTH
SCALE: 3/8" = 1'-0"D3
115-LAUNDRY
SCALE: 1/4" = 1'-0"D1
ENLARGED 115- LAUNDRY
SCALE: N.T.S.A5
TRANSITION DETAILS
UP
AUDITORIUM
TRAINING AREA
MECH
COMM
BARRACK
BARRACK
BARRACK
BARRACK
LAUNDRY
ELEV
CONF
TRAINING OFFICE
ADMIN SUITE
VESTIBULE
LOBBY
BARRACK
OFFICE
RR
COMMANDANT
OFFICE
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
OFFICE
COPY CNTR
OFFICE
TA-50 STORAGE
TEST ROOM
RECORDS ROOM
STAIR
CLOSET
STAFF BREAK
ROOM
BARRACK ACCESS
ELEC
W SHOWERS/
LOCKERS
EMR
INT. STAIR
M SHOWER/
LOCKERS
M CADRE LOCKERS
SUPPLY
W CADRE LOCKERS
SCRUB AREA
JAN CL / STO
STAIR A
ARMS ROOM
TRAINING ACCESS
KEY PLAN
PLAN NORTH
0' 8' 16' 32' 64'
SCALE: 1/16" = 1'-0"
1. REFER TO FURNITURE, FIXTURES & EQUIPMENT (FF&E) PACKAGE FOR
PROCUREMENT INFORMATION, PRODUCT SPECIFICATIONS AND
QUANTITIES.
2. REFER TO MECHANICAL AND ELECTRICAL PLANS TO COORDINATE LIGHT
SWITCHES, THERMOSTATS, DIFFUSERS AND ACCESS PANELS WITH
FURNITURE LAYOUTS. CONTRACTOR SHALL IDENTIFY ANY CONFLICTS
WITH FURNITURE LAYOUTS.
3. FURNITURE INSTALLER/CONTRACTOR SHALL COORDINATE
POWER/COMM/DATA CONNECTIONS WITH ELECTRICAL CONTRACTOR
PRIOR TO INSTALLATION OF ELECTRIFIED FURNISHINGS.
4. FF&E CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS AND SITE
CONDITIONS PRIOR TO ORDER ENTRY TO ENSURE PROPER FIT OF ALL
FF&E ITEMS. FURNISHINGS SHALL NOT OVERLAP OR OBSTRUCT
DOORWAYS, WALL SWITCHES, THERMOSTATS OR OTHER WALL-MOUNTED
ITEMS. MODIFICATIONS TO FURNISHING LAYOUTS REQUIRED TO MEET
BUILDING CONDITIONS AT THE TIME OF INSTALLATION SHALL BE THE
RESPONSIBILITY OF THE FF&E CONTRACTOR. ANY MODIFICATIONS MUST
BE APPROVED, IN WRITING, BY A GOVERNMENT APPROVED
REPRESENTATIVE PRIOR TO FF&E INSTALLATION.
FF&E PLAN NOTES:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
1/3/2017 1:24:29 PM
C:\Users\foretb\Documents\1160170_NCOA_INTERIORS_CENTRAL_R15_Bforet.rvt
IF-101
F
IR
S T
F L O
O R
F U
R N
IT
U
R E
P L A
N
N C
O A
C A
D E
M Y
C O
M P
L E
X
N E
W Y
O R
K N
E W
Y O
R K
N
Y
F
E D
E R
A L P
L A
Z A
R O
O M
N E
W Y
O R
K N
Y
-0
B F
C B
B F
M D
O C
T O
B E
R
W D
S -1
-R
-0
W -1
-D
-0
SCALE: 1/16" = 1'-0"B2
FIRST FLOOR FURNITURE PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
G
E N
E R
A L R
E V
IS
IO
N S
D E
C
AUDITORIUM
MECH
COMM
BARRACK
BARRACK
BARRACK
BARRACK
LAUNDRY
ELEV
CONF
TRAINING OFFICE
ADMIN SUITE
VESTIBULE
LOBBY
BARRACK
OFFICE
RR
COMMANDANT
OFFICE
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
OFFICE
COPY CNTR
OFFICE
TA-50 STORAGE
TEST ROOM
RECORDS ROOM
STAIR
CLOSET
STAFF BREAK
ROOM
BARRACK ACCESS
ELEC
CH8
(8)
M7 M7 M7
M7
CH1
CH3
CH2 CH2CH2 CH2
CH3
D1
D2
T1
M5
M5
M5
FC2 FC2 FC2
CH6
CH9
FC2
FC2
FC2
T1
M5
M5
M5 M7 M7
M5 M7
M7 M5
M7 M5
LEC
CH1
CH1
T2
T2
CH1
CH1
FC2
FC2
(8) FC1
CH1 (5) FC1
WR7 WR6 WR6 WR5 WR5
WR4 WR4 WR4 WR4
WR2WR2WR3WR4
WR1 WR1 WR1 WR1 WR1
FC2FC2
W SHOWERS/
LOCKERS
T3
WL
CH1 CH1
WL
WL
WL
WL
WL
WL
WL
WL
M1 M2
M1 M2
M1 M2
M1 M2
M1 M2
M1 M2
M1 M2
M1 M2
M1 M2
M A
T C
H L
IN
E
S E
E
A
I
F -1
A
DC3
WS3 WS3
WS3A
WS3WS3 WS3
WS3
DC3
DC3
TC1TC1
TC1
TC2
TC1
TC1
TC1
TC1
TC1 TC1TC1
TC1
TC1
TC1
TC1
TC1
TC1
TC1TC1
TC1
SF1
CH9
L1
L1 L1 L1
L1
L1
L1
L1
CH1
WS3
CH1
WS3
L1
ARMS ROOM
TC1
FC2
CH7
CH2 CH2
CH1
D3
WS3
T3
I-201
A1
I-202
A1
I-202
B4
I-203
B1 I-201
D4
SH1
18' - 0" 6' - 2"
CH7 (16)
CH7 (9)
T6
LOC-1LOC-1LOC-1 LOC-1LOC-1LOC-1LOC-1
LOC-1
LOC-1
LOC-1
LOC-1LOC-1
LOC-1LOC-1
LOC-1LOC-1
LOC-1LOC-1
LOC-1LOC-1
LOC-1
LOC-1LOC-1LOC-1LOC-1LOC-1LOC-1
LOC-1
LOC-1LOC-1
LOC-1LOC-1
LOC-1LOC-1
LOC-1LOC-1
LOC-1LOC-1
LOC-1
LOC-1LOC-1LOC-1LOC-1LOC-1LOC-1LOC-1 LOC-1LOC-1LOC-1LOC-1LOC-1
TC1
SHRED
SHRED
TC2TC2TC2
TC2
TC2
TC2 TC2
TC2
TC2
TC2
TC2
SH2
CH4 (4)
CH4 (4)
E4
E4
E4 E3
E3
E3
BK1 BK1
E2
E2
DC2
TC4
TC4
TC4
TC4
SHRED
CH1
T2
JAN CL / STO
EMR
INT. STAIR
BATH RM
109B
BATH RM
110B
BATH RM
111B
BATH RM
113B
BATH RM
114B
SH2SH2 SH2 SH2 SH2
SH2
SH2 SH2SH2 SH2 SH2
SH2
SH1 SH1
FOLDING
TABLE
I-203
D1
TC2
CH5 (5)
TC1
TC2
TC3
FC2 T2
CH1
CH1
T2FC2
TC1
TC2
TC1
TC2
M SHOWER/
LOCKERS
TRAINING ACCESS
INSTRUCTIONAL
ACCESS
W CADRE LOCKERS
M CADRE LOCKERS
TV1/WM1
CH2
CH2
CH2CH2 CH2 CH2 CH2 CH2
E1
SUPPLY
TV
AV-9
AV-5
0' 4' 8' 16' 32'
SCALE: 1/8" = 1'-0"
KEY PLAN
PLAN NORTH
1. REFER TO FURNITURE, FIXTURES & EQUIPMENT (FF&E) PACKAGE FOR
PROCUREMENT INFORMATION, PRODUCT SPECIFICATIONS AND
QUANTITIES.
2. REFER TO MECHANICAL AND ELECTRICAL PLANS TO COORDINATE LIGHT
SWITCHES, THERMOSTATS, DIFFUSERS AND ACCESS PANELS WITH
FURNITURE LAYOUTS. CONTRACTOR SHALL IDENTIFY ANY CONFLICTS
WITH FURNITURE LAYOUTS.
3. FURNITURE INSTALLER/CONTRACTOR SHALL COORDINATE
POWER/COMM/DATA CONNECTIONS WITH ELECTRICAL CONTRACTOR
PRIOR TO INSTALLATION OF ELECTRIFIED FURNISHINGS.
4. FF&E CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS AND SITE
CONDITIONS PRIOR TO ORDER ENTRY TO ENSURE PROPER FIT OF ALL
FF&E ITEMS. FURNISHINGS SHALL NOT OVERLAP OR OBSTRUCT
DOORWAYS, WALL SWITCHES, THERMOSTATS OR OTHER WALL-MOUNTED
ITEMS. MODIFICATIONS TO FURNISHING LAYOUTS REQUIRED TO MEET
BUILDING CONDITIONS AT THE TIME OF INSTALLATION SHALL BE THE
RESPONSIBILITY OF THE FF&E CONTRACTOR. ANY MODIFICATIONS MUST
BE APPROVED, IN WRITING, BY A GOVERNMENT APPROVED
REPRESENTATIVE PRIOR TO FF&E INSTALLATION.
FF&E PLAN NOTES:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
1/3/2017 1:24:35 PM
C:\Users\foretb\Documents\1160170_NCOA_INTERIORS_CENTRAL_R15_Bforet.rvt
IF-101B
F
IR
S T
F L O
O R
F U
R N
IT
U
R E
P L A
N
P A
R T
B
N C
O A
C A
D E
M Y
C O
M P
L E
X
N E
W Y
O R
K N
E W
Y O
R K
N
Y
F
E D
E R
A L P
L A
Z A
R O
O M
N E
W Y
O R
K N
Y
-0
B F
C B
B F
M D
O C
T O
B E
R
W D
S -1
-R
-0
W -1
-D
-0
SCALE: 1/8" = 1'-0"A1
FIRST FLOOR FURNITURE PLAN - PART B
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
G
E N
E R
A L R
E V
IS
IO
N S
D E
C
FF&E LEGEND - 1ST FLOOR
TAG ITEM DESCRIPTION
T6 18' X 5' CONFERENCE TABLE
TC1 TRASH CAN
TC2 RECYCLE CAN
TC3 LARGE TRASH CAN
TC4 LARGE RECYCLE CAN
TV FLAT SCREEN TV (GFGI)
TV1/WM1 FLAT SCREEN TV & MOUNT
WL WARDROBE
WR1 WEAPONS RACK
WR2 WEAPONS RACK
WR3 WEAPONS RACK
WR4 WEAPONS RACK
WR5 WEAPONS RACK
WR6 WEAPONS RACK
WR7 WEAPONS RACK
WS3 L SHAPED DESK
WS3A DESK
FF&E LEGEND - 1ST FLOOR
TAG ITEM DESCRIPTION
E2 MICROWAVE
E3 WASHER
E4 DRYER
FC1 VERTICAL FILE
FC2 LATERAL FILE CABINET 4H
L1 TABLE LAMP
LEC MOBILE LECTERN
LOC-1 36"W TA-50 LOCKER
M1 M2 TWIN BED AND MATTRESS
M5 STUDENT DESK
M7 DESK CHAIR
SF1 FILE SAFE
SH1 48"W METAL SHELVING
SH2 72"W METAL SHELVING
SHRED SHREDDER
T1 BREAKROOM TABLE
T2 COMPUTER TABLE
T3 END TABLE
FF&E LEGEND - 1ST FLOOR
TAG ITEM DESCRIPTION
AV-9 AV CART (GFGI)
M5 STUDENT DESK
AV-5 AV PODIUM (GFGI)
BK1 BOOKCASE
CH1 TASK CHAIR
CH2 SIDE CHAIR
CH3 EXECUTIVE TASK CHAIR
CH4 BREAK ROOM CHAIR
CH5 EXECUTIVE WOOD GUEST CHAIR
CH6 EXECUTIVE SOFA
CH7 CONFERENCE TASK CHAIR
CH8 STACKING AUDITORIUM CHAIR
CH9 EXECUTIVE LOUNGE CHAIR
CM1 COFFEE MAKER
D1 U SHAPED EXECUTIVE DESK
D2 U SHAPED EXECUTIVE DESK
D3 CONTROL DESK
DC2 60"W DIRECTORY BOARD
DC3 DISPLAY CABINET
E1 REFRIGERATOR
DN
CLASSROOM
CLASSROOM
CLASSROOM
M RR
INSTRUCTIONAL
ACCESS
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MECH
COMM
ELEV
STO / J.C.
ELEC
STUDENT BREAK
AREA
BARRACK
BARRACK
BARRACK
BARRACK
BARRACK
F RR
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
JAN CLOSET
INSTRUCTIONAL
ACCESS
CLASSROOM
LEARNING
RESOURCE CENTER
STORAGE
213A
INT. STAIR
BARRACK ACCESS
STAIR A
STAIR B
KEY PLAN
PLAN NORTH
0' 8' 16' 32' 64'
SCALE: 1/16" = 1'-0"
1. REFER TO FURNITURE, FIXTURES & EQUIPMENT (FF&E) PACKAGE FOR
PROCUREMENT INFORMATION, PRODUCT SPECIFICATIONS AND
QUANTITIES.
2. REFER TO MECHANICAL AND ELECTRICAL PLANS TO COORDINATE LIGHT
SWITCHES, THERMOSTATS, DIFFUSERS AND ACCESS PANELS WITH
FURNITURE LAYOUTS. CONTRACTOR SHALL IDENTIFY ANY CONFLICTS
WITH FURNITURE LAYOUTS.
3. FURNITURE INSTALLER/CONTRACTOR SHALL COORDINATE
POWER/COMM/DATA CONNECTIONS WITH ELECTRICAL CONTRACTOR
PRIOR TO INSTALLATION OF ELECTRIFIED FURNISHINGS.
4. FF&E CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS AND SITE
CONDITIONS PRIOR TO ORDER ENTRY TO ENSURE PROPER FIT OF ALL
FF&E ITEMS. FURNISHINGS SHALL NOT OVERLAP OR OBSTRUCT
DOORWAYS, WALL SWITCHES, THERMOSTATS OR OTHER WALL-MOUNTED
ITEMS. MODIFICATIONS TO FURNISHING LAYOUTS REQUIRED TO MEET
BUILDING CONDITIONS AT THE TIME OF INSTALLATION SHALL BE THE
RESPONSIBILITY OF THE FF&E CONTRACTOR. ANY MODIFICATIONS MUST
BE APPROVED, IN WRITING, BY A GOVERNMENT APPROVED
REPRESENTATIVE PRIOR TO FF&E INSTALLATION.
FF&E PLAN NOTES:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
1/3/2017 1:24:39 PM
C:\Users\foretb\Documents\1160170_NCOA_INTERIORS_CENTRAL_R15_Bforet.rvt
IF-102
S E
C O
N D
F L O
O R
F U
R N
I T U
R E
P L A
N
N C
O A
C A
D E
M Y
C O
M P
L E
X
N E
W Y
O R
K N
E W
Y O
R K
N
Y
F
E D
E R
A L P
L A
Z A
R O
O M
N E
W Y
O R
K N
Y
-0
B F
C B
B F
M D
O C
T O
B E
R
W D
S -1
-R
-0
W -1
-D
-0
SCALE: 1/16" = 1'-0"B2
SECOND FLOOR FURNITURE PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
G
E N
E R
A L R
E V
IS
IO
N S
D E
C
CH1
CH1
CH2 CH2
CH1 CH2
CH2
CH1
CH1
CH1
CH1
CH2 CH2
CAB2 CAB2 CAB2 CAB2 CAB2
CAB2
CAB2
CAB2
CAB2 CAB2
STAIR A
OFFICE
OFFICE
CLASSROOM
CLASSROOM
OFFICE
CLASSROOM
OFFICE
TC1
WS3
WS3
WS3
WS3
WS3
WS3
WS3
TC1
TC1
TC1
TC1
TC1
TC1
T2 T2 T2
T2
T2
T2
T2T2T2
T2
T2
T2
T2 T2 T2
T2T2T2
T2 T2 T2
T2
T2
T2
T2T2T2
CH10 (18) CH10 (18) CH10 (18)
CH2 (2)
CH2 (2)
TC2 TC2
TC2
TC2
TC2
TC2
TC2
INSTRUCTIONAL
ACCESS
CAB2
I-203
C3
T4T4T4
M A
T C
H L
IN
E
S E
E
A
I
F -1
B
CAB2
CAB2
CAB2CAB2
CAB2
CAB2
AV-9
AV-12
AV-12
AV-12
AV-12 AV-12
AV-12
0' 4' 8' 16' 32'
SCALE: 1/8" = 1'-0"
KEY PLAN
PLAN NORTH
1. REFER TO FURNITURE, FIXTURES & EQUIPMENT (FF&E) PACKAGE FOR
PROCUREMENT INFORMATION, PRODUCT SPECIFICATIONS AND
QUANTITIES.
2. REFER TO MECHANICAL AND ELECTRICAL PLANS TO COORDINATE LIGHT
SWITCHES, THERMOSTATS, DIFFUSERS AND ACCESS PANELS WITH
FURNITURE LAYOUTS. CONTRACTOR SHALL IDENTIFY ANY CONFLICTS
WITH FURNITURE LAYOUTS.
3. FURNITURE INSTALLER/CONTRACTOR SHALL COORDINATE
POWER/COMM/DATA CONNECTIONS WITH ELECTRICAL CONTRACTOR
PRIOR TO INSTALLATION OF ELECTRIFIED FURNISHINGS.
4. FF&E CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS AND SITE
CONDITIONS PRIOR TO ORDER ENTRY TO ENSURE PROPER FIT OF ALL
FF&E ITEMS. FURNISHINGS SHALL NOT OVERLAP OR OBSTRUCT
DOORWAYS, WALL SWITCHES, THERMOSTATS OR OTHER WALL-MOUNTED
ITEMS. MODIFICATIONS TO FURNISHING LAYOUTS REQUIRED TO MEET
BUILDING CONDITIONS AT THE TIME OF INSTALLATION SHALL BE THE
RESPONSIBILITY OF THE FF&E CONTRACTOR. ANY MODIFICATIONS MUST
BE APPROVED, IN WRITING, BY A GOVERNMENT APPROVED
REPRESENTATIVE PRIOR TO FF&E INSTALLATION.
FF&E PLAN NOTES:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
1/3/2017 1:24:41 PM
C:\Users\foretb\Documents\1160170_NCOA_INTERIORS_CENTRAL_R15_Bforet.rvt
IF-102A
S E
C O
N D
F L O
O R
F U
R N
IT
U
R E
P L A
N
P A
R T
A
N C
O A
C A
D E
M Y
C O
M P
L E
X
N E
W Y
O R
K N
E W
Y O
R K
N
Y
F
E D
E R
A L P
L A
Z A
R O
O M
N E
W Y
O R
K N
Y
-0
B F
C B
B F
M D
O C
T O
B E
R
W D
S -1
-R
-0
W -1
-D
-0
SCALE: 1/8" = 1'-0"A2
SECOND FLOOR FURNITURE PLAN - PART A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
G
E N
E R
A L R
E V
IS
IO
N S
D E
C
FF&E LEGEND - 2ND FLOOR
TAG ITEM DESCRIPTION
AV-12 84" SMARTBOARD (GFGI)
CAB2 STORAGE CABINET
CH1 TASK CHAIR
CH2 GUEST CHAIR
CH4 BREAK ROOM CHAIR
CH10 TRAINING CHAIR
CM1 COFFEE MAKER
DC1 60"W ANNOUNCEMENT BOARD
E1 REFRIGERATOR
E2 MICROWAVE
L1 TABLE LAMP
M1 M2 TWIN BED AND MATTRESS
M5 STUDENT DESK
M7 DESK CHAIR
SH1 48"W METAL SHELVING
T1 BREAKROOM TABLE
T2 72"W TRAINING TABLE
T4 36" VISITOR TABLE
TC1 DESK SIDE TRASH CAN
TC2 DESK SIDE RECYCLE CAN
TC4 CLASSROOM VISITOR TABLE
TV1/WM1 FLAT SCREEN TV W/ WALL MOUNT
WL WARDROBE
WS3 L SHAPED DESK
CH1 CH1CH2
CH2
CH1
CH1
CH2
CH2
CH1
CH1
CH2 CH2
CH1
CH1
CH2CH2
CH1
CH1
CH2CH2
CH1
CH1
CH2 CH2
CH1
CH1
CH2CH2
DC1
DC1
CAB2
CAB2
CAB2
CAB2
CAB2 CAB2
CAB2CAB2
CAB2 CAB2
CAB2
CAB2
CAB2 CAB2
CAB2 CAB2
CAB2
CAB2
CAB2CAB2 CAB2
CAB2CAB2
CAB2
CAB2
CAB2
CAB2CAB2CAB2
CLASSROOM
MECH
CLASSROOM
OFFICE
OFFICE
CLASSROOM
CLASSROOM
M RR
INSTRUCTIONAL
ACCESS
OFFICE
OFFICE
OFFICE
CLASSROOM
LEARNING
RESOURCE CENTER
OFFICE
OFFICE
INSTRUCTIONAL
ACCESS
OFFICE
OFFICE
OFFICE
COMM
ELEV
STO / J.C.
ELEC
STUDENT BREAK
AREA
BARRACK
BARRACK
BARRACK
BARRACK
BARRACK
F RR
STAIR B
M5 M7
L1
M5
L1
M7 L1
M5
M7
L1
L1
M5
M7
M5 M7
L1
L1
M5
M7 M7 M5
L1
L1
M5
M7M7 M5
T1
CH4
T1
CH4
CH4
CH4
CH4CH4
T1
T1 T1
CH4 CH4
CH4
CH4
CH4
CH4
CH4 CH4
CH4
CH4
BARRACK ACCESS
CH1
CH2CH2
CH1
CH2CH2
M A
T C
H L
IN
E
S E
E
A
I
F -1
A
TC1
WS3
CH2
CH2
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3
WS3WS3
WL
WL
WL WL
WL
WL
WL
WL
WLM1
M2
M1 M2
M1 M2
M1 M2
M1 M2
M1 M2
M1 M2
M1 M2
M1 M2
TC1
TC1TC1
TC1
TC1
TC1
TC1
TC1
TC1
TC1
TC1
TC1
TC1
TC1
TC1
TC1
TC1
TC1TC1
TC1
TC1
TC1
TC1
TC1
E1
I-203
B3
I-201
A4
I-202
A3
E1
E2
E2
T2T2T2
T2
T2
T2
T2 T2 T2
CH10 (18) CH10 (18)CH10 (18)
CH10 (18) CH10 (18) CH10 (18)
T2 T2
T2
T2
T2
T2
T2T2T2
T2
T2
T2 T2
T2T2T2
T2
T2
T2 T2 T2
T2
T2
T2
T2 T2 T2 T2 T2 T2
T2
T2
T2
T2T2T2 T2 T2 T2
T2
T2
T2
T2 T2 T2
I-203
C1
I-203
C3
JAN CLOSET
INT. STAIR
STORAGE
213A
T4T4T4
T4 T4 T4
TV1/WM1
SH1
TC4(2)
CAB2
CAB2
CAB2
CAB2
AV-9
AV-9 AV-9
AV-9
AV-12
AV-12
AV-12
AV-12 AV-12
AV-12
AV-12
AV-12
AV-12
AV-12
AV-12
AV-12
0' 4' 8' 16' 32'
SCALE: 1/8" = 1'-0"
KEY PLAN
PLAN NORTH
1. REFER TO FURNITURE, FIXTURES & EQUIPMENT (FF&E) PACKAGE FOR
PROCUREMENT INFORMATION, PRODUCT SPECIFICATIONS AND
QUANTITIES.
2. REFER TO MECHANICAL AND ELECTRICAL PLANS TO COORDINATE LIGHT
SWITCHES, THERMOSTATS, DIFFUSERS AND ACCESS PANELS WITH
FURNITURE LAYOUTS. CONTRACTOR SHALL IDENTIFY ANY CONFLICTS
WITH FURNITURE LAYOUTS.
3. FURNITURE INSTALLER/CONTRACTOR SHALL COORDINATE
POWER/COMM/DATA CONNECTIONS WITH ELECTRICAL CONTRACTOR
PRIOR TO INSTALLATION OF ELECTRIFIED FURNISHINGS.
4. FF&E CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS AND SITE
CONDITIONS PRIOR TO ORDER ENTRY TO ENSURE PROPER FIT OF ALL
FF&E ITEMS. FURNISHINGS SHALL NOT OVERLAP OR OBSTRUCT
DOORWAYS, WALL SWITCHES, THERMOSTATS OR OTHER WALL-MOUNTED
ITEMS. MODIFICATIONS TO FURNISHING LAYOUTS REQUIRED TO MEET
BUILDING CONDITIONS AT THE TIME OF INSTALLATION SHALL BE THE
RESPONSIBILITY OF THE FF&E CONTRACTOR. ANY MODIFICATIONS MUST
BE APPROVED, IN WRITING, BY A GOVERNMENT APPROVED
REPRESENTATIVE PRIOR TO FF&E INSTALLATION.
FF&E PLAN NOTES:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
DATE:
FILE PATH:
1/3/2017 1:24:46 PM
C:\Users\foretb\Documents\1160170_NCOA_INTERIORS_CENTRAL_R15_Bforet.rvt
IF-102B
S E
C O
N D
F L O
O R
F U
R N
IT
U
R E
P L A
N
P A
R T
B
N C
O A
C A
D E
M Y
C O
M P
L E
X
N E
W Y
O R
K N
E W
Y O
R K
N
Y
F
E D
E R
A L P
L A
Z A
R O
O M
N E
W Y
O R
K N
Y
-0
B F
C B
B F
M D
O C
T O
B E
R
W D
S -1
-R
-0
W -1
-D
-0
SCALE: 1/8" = 1'-0"A1
SECOND FLOOR FURNITURE PLAN - PART B
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
G
E N
E R
A L R
E V
IS
IO
N S
D E
C
FF&E LEGEND - 2ND FLOOR
TAG ITEM DESCRIPTION
AV-12 84" SMARTBOARD (GFGI)
CAB2 STORAGE CABINET
CH1 TASK CHAIR
CH2 GUEST CHAIR
CH4 BREAK ROOM CHAIR
CH10 TRAINING CHAIR
CM1 COFFEE MAKER
DC1 60"W ANNOUNCEMENT BOARD
E1 REFRIGERATOR
E2 MICROWAVE
L1 TABLE LAMP
M1 M2 TWIN BED AND MATTRESS
M5 STUDENT DESK
M7 DESK CHAIR
SH1 48"W METAL SHELVING
T1 BREAKROOM TABLE
T2 72"W TRAINING TABLE
T4 36" VISITOR TABLE
TC1 DESK SIDE TRASH CAN
TC2 DESK SIDE RECYCLE CAN
TC4 CLASSROOM VISITOR TABLE
TV1/WM1 FLAT SCREEN TV W/ WALL MOUNT
WL WARDROBE
WS3 L SHAPED DESK
File details come from the government source that posted it. Updated .