This document outlines requirements for environmental remediation services at Fort Belvoir, Virginia. The U.S. Army Corps of Engineers, Baltimore District intends to issue a Request for Proposal on or around July 15, 2019 for a single-award task order contract with a capacity of $45 million and minimum guarantee of $15,000. The NAICS code is 569210 for remediation services and the small business size standard is 500 employees. The base period of performance is one year with four one-year options. Services required include environmental compliance, restoration, conservation, pollution prevention, and management. Specific tasks involve compliance with regulations; investigations and remediation of soil, groundwater, and waste; demolition and disposal; laboratory services; and conservation activities such as wetlands permitting and surveys. The contract will not include construction requirements and will service Fort Belvoir exclusively. The government aims to award the contract by September 2019 and offerors must register in the System for Award Management database.

Appendix J HW Identification and Classification

View the file

Other files

File Type Posted
B.08.03_Solicitation_Amendment_4_07NOV2019.pdf PDF
B.08.03_Solicitation_Amendment_3_06NOV2019.pdf PDF
RFI_questions_and_responses_10-31-19_.pdf PDF
Section_J_-_Calibration_Protocols.pdf PDF
Section_J_-_SAA_DPW-ENRD_Inspection_Checklist_rev7MAY14.pdf PDF
Section_J_-_SAA_ECO_Inspection_Checklist_rev11JUN14.pdf PDF
B.08.03_Solicitation_Amendment_30OCT2019.pdf PDF
Section_J_-_Datasheet_template.pdf PDF
Section_J_-_APP_N_-_CFR-2012-title49-vol2-sec172-400.pdf PDF
Section_J_-_HWMMP_Dec_2014.pdf PDF
Section_J_-_Turn-in_Form.pdf PDF
Section_J_-_Guide_for_SamplingRedacted_Redacted.pdf PDF
Section_J_-_APP_M_-_90-Day_HWAS_Management_Flowchart-rev4APR14.pdf PDF
Section_J_-_APP_I_-Permitted_Facility_Inventory.pdf PDF
Section_J_-_81599_Fort_Belvoir_-_Rivanna_Station_Minor_NSR_Permit_Redacted.pdf PDF
Section_J_-_MS4_Permit_VAR040093_29_November_2018_-_31_October_2023.pdf PDF
Section_J_-16_AUG_16_-_NSR_-_North_Area_73630_Redacted.pdf PDF
Section_J_-_Visual_Assessment_template.pdf PDF
Section_J_-_Label_Reference_Sheet.pdf PDF
Section_J_-_APP_L_-_HM_HW_Compatability_Chart.pdf PDF
Section_J_-_APP_K_-_SAA_Flowcharts.pdf PDF
Section_J_-_VA0092771_Modified_Permit_May_2017.pdf PDF
Section_J_-_REP_Analytes.pdf PDF
Section_J_-_21_MAR_03_-_Title_V_Permit_70550_Redacted.pdf PDF
Section_J_-_APP_H_-_Inspection_Forms.pdf PDF
CAA_Response_to_Comments_FTBL_SATOC_Solicitation_2019.docx DOCX document
Section_J_-_Fort_Belvoir_SPCC_Plan_Signed_and_Approved_-_updated_September_2017.pdf PDF
Section_J_-_Field_Note_Reference_Sheet.pdf PDF
Section_J_-_RCRA_Final_Permit_with_Class_1_Modification_May2019.pdf PDF
Section_J_-_17_JUN_16_-_NSR_-_Consolidated_Permit_70550_Redacted.pdf PDF
B.08.02_Solicitation_W912DR19R0015-0001_24OCT2019.pdf PDF
Price_Schedule_16OCT2019.pdf PDF
Solicitation_W912DR19R0015_09OCT2019.pdf PDF
SF_LLL.pdf PDF
Past_Performance_Questionnaire_Template.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOLID WASTE

Used CFC refrigerants from totally enclosed heat transfer equipment if refrigerant is reclaimed for later use

Non‐terne plated used oil filters drained of oil?

POL‐contaminated media that fails TCLP & subject to corrective action regulation under 40 CFR 280?

Not a Hazardous Waste

F‐List (40 CFR 261.31)?

U‐List (40 CFR 261.33)?

K‐List (40 CFR 261.32)?

P‐List (40 CFR 261.33)?

Ignitable (40 CFR 261.21)?

Toxic (40 CFR 261.24)?

Corrosive (40 CFR 261.22)?

Reactive (40 CFR 261.23)?

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

No

No

No No

No

No

No

No

Yes

Yes

Yes

Yes

Hazardous Waste

Yes

Yes

Yes

Yes

Hazardous Waste Determination

*Note: A HW may be both listed & characteristic and may have more than one characteristic. Assess each waste as listed or characteristic for all criteria.

No

Is the waste characteristic?

Is the waste listed?

Is the solid waste excluded from RCRA?

NoNo

Domestic sewage or any mixture of domestic sewage that passes through a sewer system to POTW?

Recycled Scrap Metal?

No

No

Yes

Yes

Household waste?

Arsenically‐treated wood after used for its intended purpose?

Characteristic Hazardous Waste Determination Ignitable

(40 CFR 261.21)?

Toxic

(40 CFR 261.24)?

Corrosive

(40 CFR 261.22)?

Reactive

(40 CFR 261.23)?

Liquid?

Flashpoint <140o F

Capable of spontaneous or sustained combustion under normal conditions

Liquid? Aqueous solution?

Corrodes steel at a rate greater than 1/4 inch per year at a test temperature of 130o F pH of less than or equal to 2 or greater than or equal to 12.5

Normally unstable and readily undergoes violent change without detonating

Reacts violently with water

Forms potentially explosive mixtures with water

When mixed with water, generates toxic gases, vapors, or fumes

Capable of detonation or explosive decomposition or reaction at standard temperature & pressure

Readily capable of detonation or explosive decomposition at standard temperature & pressure

Forbidden explosive as defined in 49 CFR 173.51, or a Class A explosive as defined in 49 CFR 173.53, or a Class B explosive as defined in 49 CFR 173.88

EPA

WASTE

CODE

CONTAMINANT REGULATORY

LEVEL(mg/l)

D004 D005 D018 D006 D019 D020 D021 D022 D007 D023 D024 D025 D026 D016 D027 D028 D029 D030 D012 D031 D032 D033 D034 D008 D013 D009 D014 D035 D036 D037 D038 D010 D011 D039 D015 D040 D041 D042 D017 D043

ARSENIC

BARIUM

BENZENE

CADMIUM

CARBON TETRACHLORIDE

CHLORDANE

CHLOROBENZENE

CHLOROFORM

CHROMIUM

o‐CRESOL m‐CRESOL

P‐CRESOL

CRESOL

2,4‐D

1,4‐DICHLOROBENZENE

1,2‐DICHLOROETHANE

1,1‐DICHLOROETHYLENE

2,4‐DINITROTOLUENE

ENDRIN

HEPTACHLOR (and its epoxide)

HEXACHLOROBENZENE

HEXACHLOROBUTADIENE

HEXACHLOROETHANE

LEAD

LINDANE

MERCURY

METHOXYCHLOR

METHYL ETHYL KETONE

NITROBENZENE

PENTACHLOROPHENOL

PYRIDINE

SELENIUM

SILVER

TETRACHLOROETHYLENE

TOXAPHENE

TRICHLOROETHYLENE

2,4,5‐TRICHLOROPHENOL

2,4,6‐TRICHLOROPHENOL

2,4,5‐TP (Silvex)

VINYL CHLORIDE

5.0 100.0 0.5 1.0 0.5 0.03 100.0 6.0 5.0 200.0 200.0 200.0 200.0 10.0 7.5 0.5 0.7 0.13 0.02 0.008 0.13 O.5 3.0 5.0 0.4 0.2 10.0 200.0 2.0 100.0 5.0 1.0 5.0 0.7 0.5 0.5 400.0 2.0 1.0 0.2

Sample tested using TCLP has the following concentration:

No No

No

No

No

No

No

*Note: A HW may have more than one characteristic. Assess each characteristic for each waste.

Yes

Yes

Yes YesYes

Yes

D001 HW

D002 HW

D003 HW

D004‐D0043 HW

Yes

No

No

No

No No No Not a characteristic

HW

No

No

Oxidizer as defined in 49

CFR 173.151

Ignitable compressed gas as defined in 49

CFR 173.300

No

No

No

Yes

Yes