Am-0008_W9128F20R0002_Drawings_(Reissued).pdf

PDF 37 MB Posted

Attached to
Consolidated Space Operations Facility, Schriever AFB, Colorado
Solicitation number
W9128F20R0002
Issued by

About this file

This document provides details for a federal construction solicitation issued by the Department of the Army Corps of Engineers Engineering District Omaha. The solicitation is for the construction of the Consolidated Space Operations Facility and an entry control facility at Schriever Air Force Base in Colorado. The project will consist of constructing a two-story CSOF with reinforced concrete foundation, steel structure, and a low slope membrane roof. The one-story entry control facility will be constructed at the south side of the restricted area. The facilities must be designed and constructed in accordance with DoD and Air Force standards and include cybersecurity and antiterrorism/force protection measures. The contractor will be required to commence work within 10 days of notice to proceed and complete the project within 1400 calendar days, with liquidated damages for failure to meet the deadline. Performance and payment bonds are required. The solicitation includes applicable drawings, specifications and instructions to offerors.

View the file

Other files

File Type Posted
Am-0012_W9128F20R0002.pdf PDF
Am-0011_W9128F20R0002.pdf PDF
Am-0010_W9128F20R0002.pdf PDF
Am-0009_W9128F20R0002.pdf PDF
Am-0009_W9128F20R0002_Drawings-Reissued.pdf PDF
Am-0008_W9128F20R0002.pdf PDF
CSOF Part 1_Modeling Files_90 Percent Corrected Download Instructions.pdf PDF
Am-0007_W9128F20R0002.pdf PDF
Modeling Files - 90 Percent Corrected Disclaimer.pdf PDF
Am-0004_W9128F20R0002.pdf PDF
CSOF Part 9_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 2_Modeling Files_90 Percent Corrected.zip ZIP file
ECP_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 10_Modeling Files_90 Percent Corrected.zip ZIP file
Am-0005_W9128F20R0002.pdf PDF
Am-0006_W9128F20R0002.pdf PDF
CSOF Part 1_Modeling Files_90 Percent Corrected.pdf PDF
CSOF Part 7_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 3_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 6_Modeling Files_90 Percent Corrected.zip ZIP file
Am-0003_W9128F20R0002.pdf PDF
CSOF Part 5_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 8_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 4_Modeling Files_90 Percent Corrected.zip ZIP file
Am-0002_W9128F20R0002_Drawings-(Revised).pdf PDF
W9128F20R0002_Am0002_Final_Div00_Specs_Drawings.pdf PDF
CSOF Virtual Site Visit_Attendee POCs_01Apr2021.pdf PDF
W9128F20R0002_Am0001_Final.pdf PDF
CSOF_DRAWINGS_Volume 1_LS-Civil-Landscape.pdf PDF
90-Percent-Corrected_V3-SPECS_W9128F20R0002_ECP.pdf PDF
CSOF_DRAWINGS_Volume 8_Comm-Security.pdf PDF
ECP_DRAWINGS.pdf PDF
CSOF_DRAWINGS_Volume 4_Interiors.pdf PDF
Div00_W9128F20R0002.pdf PDF
90-Percent-Corrected_V1-SPECS_W9128F20R0002_CSOF-General.pdf PDF
90-Percent-Corrected_V2-SPECS_W9128F20R0002_CSOF.pdf PDF
CSOF_DRAWINGS_Volume 7_Electrical.pdf PDF
CSOF_DRAWINGS_Volume 6_Process-Mechanical.pdf PDF
CSOF Site Photo Package compressed.pdf PDF
CSOF_DRAWINGS_Volume 3_Architectural.pdf PDF
CSOF_DRAWINGS_Volume 5_Fire-Plumbing.pdf PDF
CSOF_DRAWINGS_Volume 2_Structural.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EEEEEEEEEEEEEEEEEEEEEEEEEEEEEE

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

EEEEEEEEEEEEEEEEEEEEEEE

E

E

E

E

E

E

E

E

E

E

E

E

GGGGGGGGGGGGGGGGGGGGGGGG

GGGGG

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMMCOMMCOMMCOMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

C O

M M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SANSAN

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

C P

C P

SD SD SD SD SD SD SD SD SD SD SD SD SD SD

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W W W W W W W W W W W W W W W W W W W W W

W W W W W

W W W W W W

W W

W W

W

W

W W

W

W W W W W

W W

W W

WWWWWWWWWWWWWWWWWWWWW

W

W

W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

W

W

W

W W

W W

W W

W W

W W

W W

W

W W W W W W W W W W W W W W W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

WWWWWWWWWWWWWWWW

W W

W

SD

SD

SD SD

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM

COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

COMM COMM

G G

G G

G G

G

GGGGGGGGGGGGGGG

FOSFOSFOSFOSFOSFOSFOSFOSFOSFOSFOSFOS

FO

S

FO

S

FO

S

FO

S

E E E E E E E E E E E E E E E E E E E E E E E E E E E E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SH

-G

LE

N

-3

1- C

D

4.

D

W G

CD104

SI

TE

D

EM

O

LI

TI

O

N

PL

AN

-S

H

EE

T

M

AT

C H

LI

N

E -C

D

MATCHLINE - CD102

KEYNOTES:

21+00

21+12.19

+0

+9 5.

+0

+0

+0

0+00 1+00 2+00 3+00 4+00

L2

C51

L5

E01

E03

E04

E05

R02

1+

2+

3+

L8

10+00 11+00 12+00

+0

+0

+0

+0

G G

G G

G G

G G

G G

G G

G

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

SD SD SD SD SD SD

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ESESESESESESESES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

10+00

+0

+0

+0

ES

ES

ES

ES ES ES ES ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES ES

W W W W W W W W W W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

G

+0

+0

+0

4.

FOFOFOFOFOFOFOFOFOFOFOFOFO

FO

FO

FO

FO

FOFOFOFO

FO

E E

E E

E E

E E

E E

E

E

E

E

E

E

E

E

E

E

E

E

FO

FO

FO

FO

FO

FO

FO

FO

FO

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

FO

FO FO FO FO FO FO FO FO FO FO FO FO FO

S S

W

SAN

G G

SAN SAN SAN SAN SAN SAN SAN SAN SAN

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

G

W W

WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW

G A

S G

A S

G A

S G

A S

G A

S G

A S

G A

S G

A S

G A

S G

A S

EEEEEEEEEEEEEEEEEEEEEEEEEEEEEE

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

EEEEEEEEEEEEEEEEEEEEEEE

GGGGGGGGGGGGGGGGGGGGGGGG

GGGGG

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMMCOMMCOMMCOMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

C O

M M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SANSAN

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

C P

C P

SD SD SD SD SD SD SD SD SD SD SD SD SD SD

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W W W W W W W W W W W W W W W W W W W W W

W W W W W

W W W W W W

W W

W W

W

W

W W

W

W W W W W

W W

W W

WWWWWWWWWWWWWWWWWWWWW

W

W

W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

W

W

W

W W

W W

W W

W W

W W

W W

W

W W W W W W W W W W W W W W W W

SD

SD

SD SD

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM

COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

COMM COMM

G G

G G

G G

G

GGGGGGGGGGGGGGG

FOSFOSFOSFOSFOSFOSFOSFOSFOSFOSFOSFOS

FO

S

FO

S

FO

S

FO

S

E E E E E E E E E E E E E E E E E E E E E E E E E E E E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SH

-G

LE

N

-3

1- C

G

4.

D

W G

CG104

C

IV

IL

G

R

AD

IN

G

PL

AN

-S H

EE

T

M

AT

C H

LI

N

E -C

G

MATCHLINE - CG102

STORM DRAIN RCP, 24 INCH

STORM DRAIN RCP END SECTION, CDOT M-603-10,

SEE DETAIL ON SHEET CG501

STORM DRAIN INLET, TYPE C, CDOT M-604-10,

SEE DETAIL ON SHEET CG501

KEYNOTES:

RIM EL: 6252.20

24" INV (E):6250.20

RD EL: 6253.43 S/W EL: 6254.20

24" INV (W):6250.10

EL: 6257.50

S/W EL: 6257.50

EL: 6256.50

EL: 6257.00

EL: 6256.85

EL: 6254.85

EL: 6254.75

CSOF STRM LINE D

CSOF

ECP

+0

+9 5.

C51

L5

E01

E03

E04

E05

R02

1+

2+

3+

L8

SH

-G

LE

N

-3

1- C

S1

.D W

G

CS104

C

IV

IL

SI

TE

PL

AN

-S

H

EE

T

M

AT

C H

LI

N

E -C

S1

MATCHLINE - CS102

HMA ROADWAY PAVEMENT, SEE DETAIL 1, SHEET CS501

PCC ROADWAY PAVEMENT, SEE DETAIL 3, SHEET CS501

PCC SIDEWALK, SEE DETAIL 5, SHEET CS501

PCC MOUNTABLE CURB, SEE DETAIL 8, SHEET CS501

PCC SIDEWALK CURB ADA RAMP, SEE DETAIL 1, SHEET

CS502

PCC DRAINAGE FLUME, SEE DETAILS ON CS503

METAL SAFETY RAIL, SEE DETAIL 1, SHEET CS502

KEYNOTES:

SEE NOTE 6

ON CS100

.8

2'

.0 0'

6.

.0 2'

20.00'

6.

6.

0.00'

0.00'

SEE NOTE 5

ON CS100

SEE NOTE 5

ON CS100

SEE NOTE 5

ON CS100

SEE NOTE 2

ON CS100

REFER TO CG201 PROFILE 3

FOR CSOF FIRE LANE

COORDINATE FLAT WORK WITH

STRUCTURAL STOOPS AT

BUILDING. SEE STOOP DETAILS

ONSTRUCTURAL DRAWINGS

CSOF

ECP

+0

+9 5.

+0

+0

+0

0+00 1+00 2+00 3+00 4+00

L2

C51

L5

E01

E03

E04

E05

R02

1+

2+

3+

L8

G G

G G

G G

G G

G G

G G

G

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

SD SD SD SD SD SD

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ESESESESESESESES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

10+00

+0

+0

+0

ES

ES

ES

ES ES ES ES ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES ES

W W W W W W W W W W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

G

+0

+0

+0

4.

FOFOFOFOFOFOFOFOFOFOFOFOFO

FO

FO

FO

FO

FOFOFOFO

FO

E E

E E

E E

E E

E E

E

E

E

E

E

E

E

E

E

E

E

E

FO

FO

FO

FO

FO

FO

FO

FO

FO

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

FO

FO FO FO FO FO FO FO FO FO FO FO FO FO

S S

W

SAN

G G

SAN SAN SAN SAN SAN SAN SAN SAN SAN

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N S

A N

G

W W

WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW

G A

S G

A S

G A

S G

A S

G A

S G

A S

G A

S G

A S

G A

S G

A S

EEEEEEEEEEEEEEEEEEEEEEEEEEEEEE

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

EEEEEEEEEEEEEEEEEEEEEEE

GGGGGGGGGGGGGGGGGGGGGGGG

GGGGG

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMMCOMMCOMMCOMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

C O

M M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

C

OM

M

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SANSAN

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

C P

C P

SD SD SD SD SD SD SD SD SD SD SD SD SD SD

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W W W W W W W W W W W W W W W W W W W W W

W W W W W

W W W W W W

W W

W W

W

W

W W

W

W W W W W

W W

W W

WWWWWWWWWWWWWWWWWWWWW

W

W

W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

W

W

W

W W

W W

W W

W W

W W

W W

W

W W W W W W W W W W W W W W W W

SD

SD

SD SD

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM

COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

COMM COMM

G G

G G

G G

G

GGGGGGGGGGGGGGG

FOSFOSFOSFOSFOSFOSFOSFOSFOSFOSFOSFOS

FO

S

FO

S

FO

S

FO

S

E E E E E E E E E E E E E E E E E E E E E E E E E E E E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SH

-G

LE

N

-3

1- C

U

4.

D

W G

CU104

C

IV

IL

U

TI

LI

TY

PL

AN

-S

H

EE

T

M

AT

C H

LI

N

E -C

U

MATCHLINE - CU102

KEYNOTES:

1 2 2.3 3 3.6 4 5 5.4 6 6.7 7 8 8.4 9

J

I

H

G.7

G.5

G

F.3

F

E

D.7

D

C.5

C.3

C

A

D.4

F.6

7.5 8.83.20.5 1.7 6.4 8.9

H.6

G.3

E.5

C.7

C.6

C.4

B.5

B.4

B

B.1

C.9

G.1

8.37.9

6.9

1BST4

1BST3

1BST1

1BST2

STAIR 4

ST4

1ST FLOOR IUC

1B100

1ST FLOOR IUC

1B101

1ST FLOOR IUC

1B102

1ST FLOOR IUC

1B103

STAIR 3

ST3

STAIR 1

ST1

STAIR 2

ST2

A-410

A-412

A-417

A-415

A-535

A-536

A-101

A-101

A-101

A-101

A-101

A-102

A-102

A-102

A-537

A-536

A-535

SIM

A-535

SIM

1.5 2.5

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

SOLID GRAY HATCH ON THIS PLAN

REPRESENTS THE EXTENTS OF THE

INTERSTITIAL UTILITY CORRIDOR

(IUC) AND STAIRS THAT CONNECT

TO THE IUC

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

W F

-1 C

W F

-1 -R

-0

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

4 5 6A

7 8 9A

KEY PLAN

PLAN NORTH

C S

O F

P A

C K

A G

E

5/24/2021 9:11:47 AM

A-100A

S

T F

L O

O R

I U

C

C O

M P

O S

IT

E

P L A

N

B

ID

O P

T

IO

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

3/64" = 1'-0"

1ST FLOOR IUC - COMPOSITE PLAN_BID OPTION

A

M E

N D

M E

N T

N O

/2

/2

T

T

T

T

T

T

T

T T

T

T

T

T

T

T

T

T

T

T

T

A-410

1 2 2.3 3 3.6

J

I

H

G.7

G.5

G

1F171A

1F124A

1F

B

1F

A

1F

A

1F125E

1F148A

1F145B

1F

B

3.2

UP

A-411 4B8

20A6

4B8

5B8

5B8 M1

M1

M1

1A8 4B8

4B8

2B8

4B8

4B8

4B8

0.5

/4

1"

/4

2'

"8'

1" 1'

1'

1.7

H.6

G.3

1F S

T

A-306

1F236B

1F

2J

A-307

A-307

A-309

A-422

1F146A

1F145A

1F

A1F147B1F147C1F147D1F148E1F148D1F148C

1F

B

1F

A

1F124B

DN

27' - 10" 2' - 9 5/8" 8' - 8 3/8" 35' - 4"

4' - 7" 2' - 9"3' - 4"

8"

3' - 4"

1" 15' - 11" 9' - 4 3/8" 14' - 7 5/8" 8' - 0" 11' - 5"

1F142B

10' - 5" 1' - 1" 4' - 5" A-545

A-545

/1 A-114

REFER SHEET

/1 A-112

REFER SHEET

/1 A-115

REFER SHEET

8' - 9"

1' - 3"

18' - 0" 8' - 7" 11' - 5" 12' - 0" 8' - 0" 20' - 0" 8' - 0"

1' - 3"

13' - 0"

1'

1'

1"

5'

1'

1'

1'

7'

4'

1'

8'

0"

4'

0"

2'

/2

ROOF ACCESS LADDER AND

CAGE W/ HATCH ABOVE

A-525

1F122K

1F

A

RA1

RA1

RA1

RA1

1F

C

1F

D

1F240A

1F142E

1F

2G

A-422

A-537

1'

8'

2'

1'

5'

7'

5'

1'

0"

4'

1'

1'

1/

2"

1'

1"

2'

1' - 9"

1' - 0" 14' - 1"

1' - 3"

8' - 2" 1' - 10" 26' - 7" 9' - 11" 1' - 6"

2' - 0" CLEAR

8' - 0"

2' - 0"

11' - 4" 13' - 11"

1' - 4" 1' - 4"

6' - 1" 12' - 2"

2' - 8"

2' - 0"

1' - 5"

3'

2'

7"

2'

/8

8"

9'

1'

1'

1'

1' - 8"1' - 8"

3' - 4" 3' - 4"

ST12

ST12

P12 P4 P4 P4 P4 P4 P4 P13 P5

P6

P5

P6

P5 P9

P1

P1

P1

P11

P16

P11

P5

P5

P5

P5

P11

P11

P11

P9

1.5 2.5

WORK ROOM 1

1F248

MECHANICAL

1F254

IDF

1F253

VEST

1F124

ELEC

1F170

MDF

1F143

MECHANICAL "A"

1F148

VTC ROOM

1F240

VTC ROOM

1F241

MEN

1F150

STAIR 1

ST1

UPS B

1F140

UPS A

1F141

ELECTRICAL "A"

1F146

ELECTRICAL "B"

1F145

BATTERY RM

1F144

MECHANICAL "B"

1F147

ELECTRICAL

1F142

A/V

1F236A

ELECTRICAL

1F142A

MECHANICAL

1F171

21A6

20A6

20A6

13B84B8 4B8

4B8

M4

M1

M5

20A6

4B8

M5

M5

5B8

20A3

20A3

20A3

20A3 20A3 20A6

20A6

13B8

13B8

M1

M1

20A6

M5

M1

5B8

13B8

21A3

M1

M4

M4

M5

M1

M1

20A6

M1

M1

5B8

CONCRETE STOOPS,

REFER TO STRUCTURAL

MCJ MCJ MCJ

M5

22' - 0" TO MCJ 22' - 0" TO MCJ 22' - 0" TO MCJ

8'

MCJ

MCJ

MCJ

T O

M C

J

TO MCJ

10' - 8"

TO MCJ

21' - 4"

TO MCJ

18' - 0"

MCJ MCJ

MCJMCJ

T O

M C

J

MCJ

MCJ

MCJ TO MCJ

10' - 0" T O

M C

J

MCJ

MCJ

A-540

A-540

2' - 8"

DN

20A3

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

1. OPERABLE PARTITION WITH POCKET DOORS. MIN. STC 50

2. DUAL WATER COOLER WITH BOTTLE FILLER. ABA COMPLIANT

3. 10'-0" TALL WIRE MESH PARTITIONS

4. MOP SINK

5. MOP AND BROOM HOLDER

6. RECESSED ENTRANCE FLOOR GRID W/ DRAIN BELOW (SEE PLUMBING

DRAWINGS)

7. BOLLARDS WITH INTEGRATED ACCESS CONTROL (CR) AND ABA PUSH

BUTTON CONTROL (ABA) WHERE INDICATED AT EACH SIDE OF THE

BOLLARD ON PLAN. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION

8. ALL EXPOSED TO VIEW STRUCTURAL STEEL IN THIS ROOM ARE TO

RECEIVE A SPRAY-ON INTUMESCENT EPOXY COATING SYSTEM TO MEET

THE FIRE RESISTANCE REQUIREMENTS AS NOTED ON GI001 OF THE LIFE

SAFETY DRAWINGS. THE STEEL IN THESE AREAS SHALL ALSO MEET

ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) CATEGORY 3.

GENERAL NOTE:

ALL KEYED NOTES ARE TYPICAL. ALL NOTES MAY NOT BE REPRESENTED ON

EVERY SHEET.

GENERAL NOTES:

A. REFER TO AND COORDINATE WITH LIFE SAFETY PLANS FOR ALL

REQUIRED FIRE RATED AND SMOKE RATED BARRIER AND PARTITION

LOCATIONS. WHERE LIFE SAFETY PLANS SHOW FIRE RATED AND SMOKE

RATED BARRIER AND PARTITION LOCATIONS, ALL PENETRATIONS

THROUGH THOSE PARTITIONS SHALL BE PROTECTED WITH AN

APPROVED THROUGH PENETRATING ASSEMBLY FOR THE PARTITION

TYPE. PARTITIONS SHALL MEET THE REQUIREMENTS OF NFPA 101 FOR

THE TYPE OF RATING REQUIRED.

KEYED NOTES (DENOTED BY )X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

-1 C

W F

-1 -R

-0

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

O F

P A

C K

A G

E

5/24/2021 9:11:55 AM

A-111

S

T F

L O

O R

S

E C

T O

R

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

1/8" = 1'-0"

1ST FLOOR - SECTOR 1 PLAN

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

PLAN NORTH

B. REFER TO TYPICAL MASONRY

CONTROL JOINT (MCJ) DETAIL

ON S-012 FOR ALL AREAS

NOTED ON THIS PLAN TO HAVE

A "MCJ".

A

M E

N D

M E

N T

N O

/2

/2

T

T

T

T

T

T

T

T

T

T

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

A-400

3.6 4 5 5.4 6

I

H

G.7

G.5

G1F236C

1F236D

1F

A

1F

A

1F131C

1F131D

1F

E

1F

A

1F

A

14B8

13B8 12B8

21A8

4B8

M3

14B8

M8 M7

1A8

1A8

4B8

H.6

G.3

1F236B

1F

2J

1F122G 1F122H

1F

A

C

LR

8'

2'

1'

7'

0"

1'

4'

1'

1'

1/

2" 2'

1/

2"

/8

5/

8" 8'

1'

2'

C

LR

8'

2'

1'

8'

4'

2'

8'

/4

/8

6'

8'

1"

1'

1'

/8

2'

/1 A-111

REFER SHEET

REFER SHEET

/1 A-113

/1 A-116

/1 A-115

A-545

1F

B

17' - 9" 40' - 0" 17' - 9" 22' - 3"

A-206

REFER SHEET

REFER SHEET

1F131F

1F131E

1F240A

1F132B

1F132A

9'

/8

A-537

A-537

2'

1'

/2

8"

4' - 4"

2' - 10" TO MCJ

6' - 4" 2' - 10" 4' - 0 1/4"10' - 5 3/8" 6' - 0" 13' - 2" 7"

1' - 0"

5' - 4" 11' - 5"

1'

2' - 8"

3' - 3"

3'

1"

6'

1'

1'

9'

2'

2'

30' - 3" 13' - 8 1/2" 37' - 7 1/2" 15' - 8 3/8"

2' - 7 5/8"

2' - 10"

2' - 8"

1' - 8" 16' - 1" 40' - 0" 16' - 11 1/2" 4' - 0" 15' - 11"

3' - 1 1/2"

COUNTER &

CABINETS,

REFER TO

8'

ST12

ST12

P9 P1 P1 P1 P1 P1 P1 P1 P1 P1 P9

1F

F

OFFICE

1F233

RECYCLING

1F135

SECURITY

1F230

VTC ROOM

1F240

VTC ROOM

1F241

CORRIDOR

1F122

NSDC OPS FLOOR

1F236

WOMEN

1F149

MEN

1F150

SHIPPING/RECEIVING

1F131

STORAGE

1F133

JAN.

1F137

VEST

1F132

STORAGE

1F134

NURSING MOTHER

1F136

A/V

1F236A

ST-2

1F239

VESTIBULE

1F131A

VESTIBULE

1F131B

ST-2

1F239

20A6

14B8

M8

14B8

13B8

21A8

13B8

4B8

14B8

M5

21A6

4B8

21A3

M1

M7

M7

M8

M4

M8

M7

M7

M8

M4

M31A8

M7

1A8

MCJ

T

O M

C J

MCJ

MCJ

12' - 0" TO MCJ

MCJ

9'

T O

M C

J

MCJ

MCJ

12' - 0" TO MCJ 20' - 0" TO MCJ

20A3

MCJ

MCJ

MCJ

9'

9'

MCJ

MCJ

20A3

6' - 0" 10' - 1"

2'

1' - 0"

5' - 0"

/1 A-114

REFER SHEET

REFER SHEET REFER SHEET

/9 I-506

1. OPERABLE PARTITION WITH POCKET DOORS. MIN. STC 50

2. DUAL WATER COOLER WITH BOTTLE FILLER. ABA COMPLIANT

3. 10'-0" TALL WIRE MESH PARTITIONS

4. MOP SINK

5. MOP AND BROOM HOLDER

6. RECESSED ENTRANCE FLOOR GRID W/ DRAIN BELOW (SEE PLUMBING

DRAWINGS)

7. BOLLARDS WITH INTEGRATED ACCESS CONTROL (CR) AND ABA PUSH

BUTTON CONTROL (ABA) WHERE INDICATED AT EACH SIDE OF THE

BOLLARD ON PLAN. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION

8. ALL EXPOSED TO VIEW STRUCTURAL STEEL IN THIS ROOM ARE TO

RECEIVE A SPRAY-ON INTUMESCENT EPOXY COATING SYSTEM TO MEET

THE FIRE RESISTANCE REQUIREMENTS AS NOTED ON GI001 OF THE LIFE

SAFETY DRAWINGS. THE STEEL IN THESE AREAS SHALL ALSO MEET

ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) CATEGORY 3.

GENERAL NOTE:

ALL KEYED NOTES ARE TYPICAL. ALL NOTES MAY NOT BE REPRESENTED ON

EVERY SHEET.

GENERAL NOTES:

A. REFER TO AND COORDINATE WITH LIFE SAFETY PLANS FOR ALL

REQUIRED FIRE RATED AND SMOKE RATED BARRIER AND PARTITION

LOCATIONS. WHERE LIFE SAFETY PLANS SHOW FIRE RATED AND SMOKE

RATED BARRIER AND PARTITION LOCATIONS, ALL PENETRATIONS

THROUGH THOSE PARTITIONS SHALL BE PROTECTED WITH AN

APPROVED THROUGH PENETRATING ASSEMBLY FOR THE PARTITION

TYPE. PARTITIONS SHALL MEET THE REQUIREMENTS OF NFPA 101 FOR

THE TYPE OF RATING REQUIRED.

KEYED NOTES (DENOTED BY )X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

-1 C

W F

-1 -R

-0

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

O F

P A

C K

A G

E

5/24/2021 9:12:01 AM

A-112

S

T F

L O

O R

S

E C

T O

R

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

PLAN NORTH

1/8" = 1'-0"

1ST FLOOR - SECTOR 2 PLAN

B. REFER TO TYPICAL MASONRY

CONTROL JOINT (MCJ) DETAIL

ON S-012 FOR ALL AREAS

NOTED ON THIS PLAN TO HAVE

A "MCJ".

A

M E

N D

M E

N T

N O

/3

/2

A

M E

N D

M E

N T

N O

/2

/2

T

T

T

T

T

T

T

T T

T

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

A-412

6 6.7 7 8 8.4 9

I

H

G.7

G.5

G

1F

A

1F120A

F.6

7.5 8.8

1F

A

1F

A

14B8

13B8

4B8

20B6

M3

4B8

4B8

4B8

4B8

20A6

14B8 20A3

3B8

4B8

1F119A

1F118A

6.4 8.9

H.6

G.3

1F102A

G.1

8.37.9

20' - 0" 18' - 0" 8"

1' - 4"

1' - 4"

1F

D

1FST2

1F109A

A-309

1F129A

UP

C

LR

8'

2'

1'

7'

/8

A-545

A-401

1F

A

/1 A-112

REFER SHEET

REFER SHEET

/1 A-116

A-545

1F

B

1F

A

ST1

ST1

ST1

ST1

ST1

ST1ST1

1F

A

1F

B

1F

B

7'

4'

5'

2' - 11" 12' - 0"

1F110C ST1

13' - 8"

1' - 5 1/2"

11' - 11 3/4"

10 3/4"

12' - 0" 1' - 5" 18' - 7" 2' - 11" 15' - 1" 2' - 0" 1' - 4" 16' - 8" 2' - 0" 8' - 0" 3' - 4" 6' - 8"

1'

8'

/4

1'

/4

4'

4'

/4

7'

/4

2'

2'

/2

1/ 2"

RA1

1F131F

1F131E

/1 A-115

REFER SHEET

1F110A

A-457

1F

A

1F

A

8"

1' - 6"

15' - 3" 11' - 10 1/4" 3' - 10 3/4" 9' - 0" 22' - 11" 17' - 1" 20' - 0" 18' - 0"

9'

1'

3' - 1 7/8"

8' - 0"

2' - 0" 1' - 5"

18' - 7"

1' - 2"

7' - 6"

1' - 0"

3' - 4" 5' - 0"

1' - 4"

18' - 8"

1' - 9"

3" 18' - 0"

6'

/2

/2

4'

/2

5'

1/ 2"

5'

1/ 2"

2'

/2

2'

/2

2'

9'

2' - 7 5/8"

8'

1'

5/ 8"

1'

/8

9'

3/ 4" 6

1/ 4"

1'

1'

1'

3'

2'

1' - 11"

1' - 2 1/2"

1' - 6"

1' - 2 1/2"

1' - 2" 13' - 9" 12' - 0"

1' - 1"

2' - 0"

11' - 10" 27' - 1" 17' - 11"

1' - 9"

1/ 2"

2'

/8

9'

/8

2'

/8

1'

10' - 8 1/2"

1' - 5 1/2"

13' - 2 1/8"

RA1

5 4

P10P10

P9

P10

P1 P1

P1

P1

P10

P10

P10

P10

P10

P10 P10P9 P1 P15 P1 P1

P9

P10

P11 P11 P11 P11 P16

ST1

I-407

I-407

PC-1

1F231

ST-1

1F232

OFFICE

1F233

IDF

1F130

DINING

1F110

SECURITY

1F230

CORRIDOR

1F106

VESTIBULE

1F123

STAIR 2

ST2

SERVICE

ELEVATOR

ELEV 1

BREAKROOM

1F237

PANTRY

1F238

MECHANICAL

1F111

ELECTRICAL RM

1F118

NIPR ROOM

1F102

MAIL RM

1F119

JAN

1F109

MENS

1F108

WOMENS

1F107

PRIVATE DINING

1F129

SECURITY

1F230

DISHWASH

1F110B

COOLER

1F110C

DRY STORAGE

1F110EKITCHEN / PREP

1F110A

COFFEE

1F110F

VESTIBULE

1F131A

VESTIBULE

1F131B

DINING

1F110

ST-2

1F239

1A6

4B8

4B8

14B8

4B8

4B8

4B8

4B8

2B8

6B6

14B8

13B8

14B8

6B6

3B8

14B8

2B8

1A6

20A6

21A3 20A6

20B320A3

M7

M3

M7

M8

22A3

22A322A3

22A3

22A3

22A3

22A3

22A3

20A3

2B8

4B8

1B8

1B8

M7

4B8

10B8

10B8

20B6 2B8

9B

CONCRETE STOOPS,

REFER TO STRUCTURAL

CONCRETE STOOP,

REFER TO

STRUCTURAL

9'

9'

MCJ

MCJ

20B6

20B3

5B8

2B8 1A6

2B8

8' - 8" MCJ

REFER SHEET

1F

A

REFER SHEET

ST1ST1

20B3

20B3

20B3

20B3

20B3

3B8

1. OPERABLE PARTITION WITH POCKET DOORS. MIN. STC 50

2. DUAL WATER COOLER WITH BOTTLE FILLER. ABA COMPLIANT

3. 10'-0" TALL WIRE MESH PARTITIONS

4. MOP SINK

5. MOP AND BROOM HOLDER

6. RECESSED ENTRANCE FLOOR GRID W/ DRAIN BELOW (SEE PLUMBING

DRAWINGS)

7. BOLLARDS WITH INTEGRATED ACCESS CONTROL (CR) AND ABA PUSH

BUTTON CONTROL (ABA) WHERE INDICATED AT EACH SIDE OF THE

BOLLARD ON PLAN. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION

8. ALL EXPOSED TO VIEW STRUCTURAL STEEL IN THIS ROOM ARE TO

RECEIVE A SPRAY-ON INTUMESCENT EPOXY COATING SYSTEM TO MEET

THE FIRE RESISTANCE REQUIREMENTS AS NOTED ON GI001 OF THE LIFE

SAFETY DRAWINGS. THE STEEL IN THESE AREAS SHALL ALSO MEET

ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) CATEGORY 3.

GENERAL NOTE:

ALL KEYED NOTES ARE TYPICAL. ALL NOTES MAY NOT BE REPRESENTED ON

EVERY SHEET.

GENERAL NOTES:

A. REFER TO AND COORDINATE WITH LIFE SAFETY PLANS FOR ALL

REQUIRED FIRE RATED AND SMOKE RATED BARRIER AND PARTITION

LOCATIONS. WHERE LIFE SAFETY PLANS SHOW FIRE RATED AND SMOKE

RATED BARRIER AND PARTITION LOCATIONS, ALL PENETRATIONS

THROUGH THOSE PARTITIONS SHALL BE PROTECTED WITH AN

APPROVED THROUGH PENETRATING ASSEMBLY FOR THE PARTITION

TYPE. PARTITIONS SHALL MEET THE REQUIREMENTS OF NFPA 101 FOR

THE TYPE OF RATING REQUIRED.

KEYED NOTES (DENOTED BY )X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

-1 C

W F

-1 -R

-0

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

O F

P A

C K

A G

E

5/24/2021 9:12:08 AM

A-113

S

T F

L O

O R

S

E C

T O

R

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

PLAN NORTH

1/8" = 1'-0"

1ST FLOOR - SECTOR 3 PLAN

B. REFER TO TYPICAL MASONRY

CONTROL JOINT (MCJ) DETAIL

ON S-012 FOR ALL AREAS

NOTED ON THIS PLAN TO HAVE

A "MCJ".

A

M E

N D

M E

N T

N O

/3

/2

A

M E

N D

M E

N T

N O

/2

/2

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

A-425

A-400

A-206

1 2 2.3 3 3.6

G

E

D.7

D

1F

A

1F215A

1F

A

1F

A

1F

A

1F

A

1F249A

1F

B

1F

A

1F

A

1F241F

1F

A

1F125A

1F125B

1F125C

1F212D

1F

C

1F

B

1F

A

D.4

F.6

4B8

4B8

20A6

14B814B8

20A6

13B8

13B8

13B8

4B8

4B8

14B8

12B8

4B8

5B8

4B8

5B8

5B8

5B8

5B8

5B8

5B8

13B8

4B8

4B8

20A6

20A6

20A6

20A6

14B8

4B8

0.5 1.7

E.5

2' - 1" 1' - 6"

6' - 3"

1' - 7"

2' - 0"

CLR.

8' - 0"

2' - 0"

1' - 5"

8' - 10 3/4" 17' - 8 1/4" 1' - 2"

CLR.

6' - 0"

4' - 10 1/2"

6' - 1 1/2"

4' - 1"

A-305

3'

1"

3'

1"

9'

0"

0"

1F125F

4'

1F242B

1F

B

9' - 5 1/2" 28' - 4 1/2"

5'

0"

2'

/2

1/ 2"

4'

8'

9'

/1 A-115

12' - 10 1/2"

/1 A-111

REFER SHEET

REFER SHEET

/1 A-117

REFER SHEET

REFER SHEET

/1 A-118

A-206

A-546

1F171C

1F214A

10' - 0" 26' - 7" 9' - 9"

1' - 8" 2' - 0"

8' - 0"

2' - 0"

1' - 5" 25' - 1"

1' - 6" 1' - 6"

1' - 8"

RA1

RA1

RA1

1F241A

1F236E

1F218A

ST3

ST3

DN

A-422

1F217C

1F

A

2' - 8 1/2" 36' - 6" 1' - 6" 4' - 0" 10' - 10"

1' - 7"

2' - 0"

2' - 0"

1' - 5" 24' - 6 1/2"

3' - 2 1/2"

CLEAR

6' - 0"

2' - 0"

8' - 0"

1'

7"

5' - 6" 12' - 7" 2' - 8"

1' - 8" 2' - 0"

7' - 3 1/2" 2' - 8 1/2" 26' - 7" 11' - 5"

2' - 0"

8' - 0" 2' - 0" 12' - 9" 15' - 3" 7' - 5" 12' - 2" 2' - 8"

1'

2'

/2

1/ 2"

7'

1/ 2"

1'

/2

7'

5'

0"

8'

0"

1'

1'

1'

6'

2'

1/ 2"

1/ 2"

1'

0"

/4

0"

1' - 8" 2'

RA1

ST12

ST12

P1

P1

P1

P1

P1

P9

P1

P1

P1

P1

P1

P1

P1

1F

A

HELP DESK

1F225

BREAKOUT

1F226

BREAKOUT

1F247

WORK ROOM 2

1F249

WORK ROOM 1

1F248

VTC ROOM

1F241

VTC ROOM

1F242

BREAKOUT

1F246

BREAKOUT

1F213

WORK ROOM

1F215

WORK ROOM

1F216

VTC ROOM

1F224

VTC ROOM

1F218

TOILET

1F250

TOILET

1F251

TOILET

1F252

MECHANICAL

1F171

SERVER ROOM A

1F172

SERVER ENTRY

1F173

SERVER ROOM B

1F174

ELEV 4

ELEV 4

ELEVATOR LOBBY

1F212

CORRIDOR

1F125

CONTROL CLST

1F227

A/V

1F236A

SERVER ROOM B

1F174

A/V

1F242A

SERVER ROOM A

1F172

MECHANICAL

1F171

CORRIDOR

1F214

13B8

4B8

20A6

20A6

4B8

4B8

4B8

4B8 4B8

4B8

20A6

13B8

14B8

4B8

21A6

20A6

20A6

21A6

13B84B8 4B8

4B8

4B8

4B8

14B8

14B8

14B8

5B8

4B8

4B8

13B8

4B8

14B8

13B8

4B84B8

1A8

4B8

21A6

1A6

13B8 21A6

13B8

13B8

13B8

12B8

4B8

4B8

4B8

13B8

4B8

4B8

5B8

20A6

20A6

5B8

4B8

5B8

5B8

4B8

5B8

1F

B

CONCRETE STOOP,

REFER TO

STRUCTURAL

2' - 1" 1' - 6"

6'

6'

9'

3'

1"

3'

1"

9'

0"

0"

5'

0"

5'

0"

0"

/1 A-112

REFER SHEET

REFER SHEET

/1 A-117

RA1

21A6

5B820A6

1. OPERABLE PARTITION WITH POCKET DOORS. MIN. STC 50

2. DUAL WATER COOLER WITH BOTTLE FILLER. ABA COMPLIANT

3. 10'-0" TALL WIRE MESH PARTITIONS

4. MOP SINK

5. MOP AND BROOM HOLDER

6. RECESSED ENTRANCE FLOOR GRID W/ DRAIN BELOW (SEE PLUMBING

DRAWINGS)

7. BOLLARDS WITH INTEGRATED ACCESS CONTROL (CR) AND ABA PUSH

BUTTON CONTROL (ABA) WHERE INDICATED AT EACH SIDE OF THE

BOLLARD ON PLAN. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION

8. ALL EXPOSED TO VIEW STRUCTURAL STEEL IN THIS ROOM ARE TO

RECEIVE A SPRAY-ON INTUMESCENT EPOXY COATING SYSTEM TO MEET

THE FIRE RESISTANCE REQUIREMENTS AS NOTED ON GI001 OF THE LIFE

SAFETY DRAWINGS. THE STEEL IN THESE AREAS SHALL ALSO MEET

ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) CATEGORY 3.

GENERAL NOTE:

ALL KEYED NOTES ARE TYPICAL. ALL NOTES MAY NOT BE REPRESENTED ON

EVERY SHEET.

GENERAL NOTES:

A. REFER TO AND COORDINATE WITH LIFE SAFETY PLANS FOR ALL

REQUIRED FIRE RATED AND SMOKE RATED BARRIER AND PARTITION

LOCATIONS. WHERE LIFE SAFETY PLANS SHOW FIRE RATED AND SMOKE

RATED BARRIER AND PARTITION LOCATIONS, ALL PENETRATIONS

THROUGH THOSE PARTITIONS SHALL BE PROTECTED WITH AN

APPROVED THROUGH PENETRATING ASSEMBLY FOR THE PARTITION

TYPE. PARTITIONS SHALL MEET THE REQUIREMENTS OF NFPA 101 FOR

THE TYPE OF RATING REQUIRED.

KEYED NOTES (DENOTED BY )X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

-1 C

W F

-1 -R

-0

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

O F

P A

C K

A G

E

5/24/2021 9:12:14 AM

A-114

S

T F

L O

O R

S

E C

T O

R

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1/8" = 1'-0"

1ST FLOOR - SECTOR 4 PLAN

PLAN NORTH

A

M E

N D

M E

N T

N O

/3

/2

A

M E

N D

M E

N T

N O

/2

/2

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

A-419

3.6 4 5 5.4 6

G

F.3

F

E

D.7

D

1F

A

1F

A

1F

A

1F244A

1F223A

1F

A

1F

A

1F

A

1F

C

1F

D

1F

E

1F236A

1F236C

1F

B

1F

A

1F217B

1F

A

1F

C

1F121A

1F229A

1F222A

D.4

F.6

14B8

14B8

14B8

14B814B8

13B8

4B8

13B8

4B8

4B8

14B8

14B8 14B814B8

4B8

4B8

4B8

4B8

4B8

20A3

20A3

4B8

13B8

15B8

15B8

15B8

14B8

14B8

3B8

5B8

4B8

4B8

4B8

20A3

4B8

4B8

4B814B8

4B8

13B8

E.5

1F

A

4' - 1"

6' - 11" 10' - 0" 8' - 6" 25' - 6 1/2" 5' - 10 1/4" 11' - 7 3/4" 7' - 0 1/2" 20' - 11"

5' - 6" 6 1/2" 19' - 4" 2' - 11"

1' - 0"

A-420

A-404

1F242B

1F223B

1F S

T

UP

UP

4'

/2

6" 1'

1'

1/

2"

3'

0"

REFER SHEET

/1 A-114

/1 A-111

REFER SHEET

/1 A-112

REFER SHEET

A-206

100' - 6"

100' - 6"

1' - 8" 16' - 1" 40' - 0" 16' - 11 1/2" 9 1/2" 16' - 3 1/2"

2' - 10"

2' - 9 1/2"

4"

ST4

GW1

GW1

ST11

A-206

A-320

A-320

RA1

RA1

RA1

RA1

RA1

RA1

1F241A

REFER SHEET

/1 A-119

1F

B

/1 A-116

REFER SHEET

REFER SHEET

/1 A-118

1F230C

1F

C

1F

B

1F236E

1F217C

1F

A

C

LR

8'

1'

0"

1'

A-537

A-537

A-537

7' - 6" 25' - 0" 7' - 6"

1'

2'

.0

150.00°

0.

2'

1'

/2

8'

4'

/2

1'

12' - 10 1/2" 13' - 10 1/2" 25' - 6 1/2" 18' - 6"

4'

1/

2"

7'

1/ 2"

6'

/2

5'

1'

0"

3'

3/ 4"

3/

4"

5' - 5 1/2" 1' - 3 1/2"

16' - 1" 7' - 6" 25' - 0" 24' - 5 1/2" 9 1/2"

3' - 2 1/2"

15' - 11"

2' - 9 1/2"

1'

/4

1' - 2"

2' - 8"

2' - 8"

1'

2' - 8"

0"

2'

2'

/2

/2

9'

3'

3'

1' - 4" 1' - 0"

7'

1'

8'

4'

1'

6"

8'

0"

1'

/2

7'

/2

6'

/2

8'

5'

1' - 8"

RA1

1F S

T

COUNTER &

CABS. ON

DECKCOUNTER &

CABS. ON DECK

EDGE OF RAISED

PLATFORM

EDGE OF RAISED

PLATFORM

COUNTER &

CABS. ON DECK

COUNTER &

CABS. ON DECK

ST12

ST12

1F

A

MP-1

1F244

STORAGE

1F235

BATTLE CAB

1F223

HELP DESK

1F225

BREAKOUT

1F226

BREAKOUT

1F247

LOCKER RM

1F207

A/V SERVER

1F243

ELEC

1F222

A/V SERVER

1F221

VTC ROOM

1F241

VTC ROOM

1F242

BREAKOUT

1F246

BREAKOUT

1F245

VTC ROOM

1F224

VTC ROOM

1F218

NSDC OPS FLOOR

1F236

BREAKROOM

1F237

PANTRY

1F238

ESS

1F234

SHADOW OPS

FLOOR

1F217

FITNESS

STORAGE

1F205

CORRIDOR

1F214

STAIR 6

ST6

STAIR 5

ST5

CREW BRIEFING

RM

1F220

CONTROL CLST

1F228

TRANSITION

GROUP

1F229

A/V

1F236A

A/V

1F206

FITNESS

1F204

A/V

1F242A

CUST. SERVICE

1F230A

VESTIBULE

1F244A

SECURITY

1F230

CORRIDOR

1F214

ST-2

1F239

4B8

4B8

1B8

4B8

4B8

4B8

14B8

20A3

12B8

4B84B8

14B8

13B8

13B8

13B8

21A6

4B8

4B8

4B8

14B8

13B8

4B8

4B84B84B8

14B8

1A6

4B8

20A3

20A320A320A34B8

13B8

13B8

13B8

4B8

4B8

4B8

4B8

4B8

1A8

1F

B

14B8

2'

0"

T Y

P .0

T Y

P .0

/1 A-113

REFER SHEET

REFER SHEET

/1 A-117

13B8

1A6 1A6

1A6 13B8

4B8

1. OPERABLE PARTITION WITH POCKET DOORS. MIN. STC 50

2. DUAL WATER COOLER WITH BOTTLE FILLER. ABA COMPLIANT

3. 10'-0" TALL WIRE MESH PARTITIONS

4. MOP SINK

5. MOP AND BROOM HOLDER

6. RECESSED ENTRANCE FLOOR GRID W/ DRAIN BELOW (SEE PLUMBING

DRAWINGS)

7. BOLLARDS WITH INTEGRATED ACCESS CONTROL (CR) AND ABA PUSH

BUTTON CONTROL (ABA) WHERE INDICATED AT EACH SIDE OF THE

BOLLARD ON PLAN. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION

8. ALL EXPOSED TO VIEW STRUCTURAL STEEL IN THIS ROOM ARE TO

RECEIVE A SPRAY-ON INTUMESCENT EPOXY COATING SYSTEM TO MEET

THE FIRE RESISTANCE REQUIREMENTS AS NOTED ON GI001 OF THE LIFE

SAFETY DRAWINGS. THE STEEL IN THESE AREAS SHALL ALSO MEET

ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) CATEGORY 3.

GENERAL NOTE:

ALL KEYED NOTES ARE TYPICAL. ALL NOTES MAY NOT BE REPRESENTED ON

EVERY SHEET.

GENERAL NOTES:

A. REFER TO AND COORDINATE WITH LIFE SAFETY PLANS FOR ALL

REQUIRED FIRE RATED AND SMOKE RATED BARRIER AND PARTITION

LOCATIONS. WHERE LIFE SAFETY PLANS SHOW FIRE RATED AND SMOKE

RATED BARRIER AND PARTITION LOCATIONS, ALL PENETRATIONS

THROUGH THOSE PARTITIONS SHALL BE PROTECTED WITH AN

APPROVED THROUGH PENETRATING ASSEMBLY FOR THE PARTITION

TYPE. PARTITIONS SHALL MEET THE REQUIREMENTS OF NFPA 101 FOR

THE TYPE OF RATING REQUIRED.

KEYED NOTES (DENOTED BY )X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

-1 C

W F

-1 -R

-0

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

O F

P A

C K

A G

E

5/24/2021 9:12:21 AM

A-115

S

T F

L O

O R

S

E C

T O

R

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

PLAN NORTH

1/8" = 1'-0"

1 1ST FLOOR - SECTOR 5 PLAN

A

M E

N D

M E

N T

N O

/3

/2

A

M E

N D

M E

N T

N O

/2

/2

T

T

T

T T

T

T T

T T

T

T

T

T

T T

T

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

A-200

A-401

6 6.7 7 8 8.4 9

G

F.3

F

E

D.7

D

1F104A

1F

A

1F121A

1F229A

D.4

F.6

7.5 8.8

1F

A

14B8

4B8

4B8

4B8

20A3

20A3

3B8

3B8

4B8

20A6

20A3

20A3 1A8

7'

/4

4'

3'

7'

/4

/4

1'

8'

8'

1'

1F119A

1F118A

6.4 8.9

E.5

1F

B

1F102A

A-426

G.1

8.37.96.9

A-406

A-306

1F109A

1F100D

1F100C

ST1

ST1

ST1

15' - 5"

25' - 6" 1' - 11"

1' - 7"

8' - 0"

1' - 4"

6 1/8" 10' - 6 7/8" 10' - 9"

/1 A-118

REFER SHEET

A-206

A-404

1F101A

1F100B

1F100A

ST1

ST1

ST1

ST1

2' - 4"

13' - 4" 1' - 0" 20' - 0" 1' - 2" 16' - 10" 2' - 0" 18' - 0" 2' - 0" 8' - 0" 3' - 4" 6' - 8"

2'

2'

/2

1/ 2"

8'

8'

2'

A-401

RA1

D.5

1F

C

1F

B

REFER SHEET

/1 A-119

1F101B

1F101C

1F101D

1F204D

1F

A

1F230C

1F

A

1F

A

CR

ABA

ABA

1'

1'

3'

2'

3' - 1 1/2"

2' - 0"

CLEAR

8' - 0" 2' - 0"

1' - 4" 1' - 0"

4'

/4

3/

8"

/8

1' - 0"

2'

15' - 5"

7'

/2

3'

/2

1'

0"

1'

3/ 8"

5'

/8

5'

1"

/2

3'

3/ 4"

5'

0"

3'

4'

/4

C

LE

A R

8'

5' - 0" 12' - 2 3/4" 5' - 3 1/4" 10' - 7 1/4"

2' - 10"

7' - 0"

2' - 9 1/2"

1' - 6"

6' - 11 1/2" 3' - 2" 6' - 11 1/4"

3' - 9 1/4"

5' - 2"

6'

3/ 4"

7'

/2

5' - 6"

1' - 2 1/2"

2' - 8" 11' - 0" 13' - 2 1/8"

1' - 1 7/8"

2' - 0"

9' - 10"1' - 10"

10' - 8 1/2"

1' - 5 1/2"

13' - 2 1/8"

1'

0"

2'

2'

/2

RA1

5 4

P10P10

P3

P3

P3

P3

P3

P14P14P14P14

P1

P1

P3

P1 P1

P1

P1

P10

CR &

ABA

CR &

ABA

CR & ABA

PC-1

1F231

LOCKER RM

1F201

LOCKER RM

1F207

SHOWER

1F202

STORAGE

1F105

VESTIBULE

1F100

TRANSITION

GROUP

1F229

FITNESS

1F204

CORRIDOR

1F106

BREAKROOM

1F237

PANTRY

1F238

ESS

1F234

ELEV 3

ELEV 3

ELEV 2

ELEV 2

SHOWER

1F208

ELEVATOR LOBBY

1F121

CORRIDOR

1F120

LOBBY

1F101

CONTROL CLST

1F228

ELECTRICAL RM

1F118

NIPR ROOM

1F102

MAIL RM

1F119

JAN

1F109

WOMENS

1F107

GUARD STATION

1F103

SECURITY

1F230

SECURITY

1F230

FITNESS

1F204

INTERVIEW RM

1F104

COFFEE

1F110F

SECURITY

1F230

4B8

13B8

1A6

4B8

1B8

1B8

4B8

1B8

14B8

4B8

20A6

21A6

4B8

4B8

2B8

6B6

14B8

1A8

1A6

20A6

4B8

14B8

14B8

21A3 20A6

20B320A3

20A3

20A320A320A3

20A3

20A3

20A3

20A3

20A620A6

4B8

1B8

1B8

4B8 9B

CONCRETE STOOP,

REFER TO STRUCTURAL

A-458

1A6

A-540

A-540

A-540

/1 A-113

REFER SHEET

1F

A

/1 A-118

REFER SHEET

/1 A-112

REFER SHEET

/1 A-113

REFER SHEET

ST1ST1

20B3

1A6

20A38 8

1. OPERABLE PARTITION WITH POCKET DOORS. MIN. STC 50

2. DUAL WATER COOLER WITH BOTTLE FILLER. ABA COMPLIANT

3. 10'-0" TALL WIRE MESH PARTITIONS

4. MOP SINK

5. MOP AND BROOM HOLDER

6. RECESSED ENTRANCE FLOOR GRID W/ DRAIN BELOW (SEE PLUMBING

DRAWINGS)

7. BOLLARDS WITH INTEGRATED ACCESS CONTROL (CR) AND ABA PUSH

BUTTON CONTROL (ABA) WHERE INDICATED AT EACH SIDE OF THE

BOLLARD ON PLAN. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION

8. ALL EXPOSED TO VIEW STRUCTURAL STEEL IN THIS ROOM ARE TO

RECEIVE A SPRAY-ON INTUMESCENT EPOXY COATING SYSTEM TO MEET

THE FIRE RESISTANCE REQUIREMENTS AS NOTED ON GI001 OF THE LIFE

SAFETY DRAWINGS. THE STEEL IN THESE AREAS SHALL ALSO MEET

ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) CATEGORY 3.

GENERAL NOTE:

ALL KEYED NOTES ARE TYPICAL. ALL NOTES MAY NOT BE REPRESENTED ON

EVERY SHEET.

GENERAL NOTES:

A. REFER TO AND COORDINATE WITH LIFE SAFETY PLANS FOR ALL

REQUIRED FIRE RATED AND SMOKE RATED BARRIER AND PARTITION

LOCATIONS. WHERE LIFE SAFETY PLANS SHOW FIRE RATED AND SMOKE

RATED BARRIER AND PARTITION LOCATIONS, ALL PENETRATIONS

THROUGH THOSE PARTITIONS SHALL BE PROTECTED WITH AN

APPROVED THROUGH PENETRATING ASSEMBLY FOR THE PARTITION

TYPE. PARTITIONS SHALL MEET THE REQUIREMENTS OF NFPA 101 FOR

THE TYPE OF RATING REQUIRED.

KEYED NOTES (DENOTED BY )X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

-1 C

W F

-1 -R

-0

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

O F

P A

C K

A G

E

5/24/2021 9:12:27 AM

A-116

S

T F

L O

O R

S

E C

T O

R

P L A

N

B A

S E

B

ID

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

PLAN NORTH

1/8" = 1'-0"

1ST FLOOR - SECTOR 6 PLAN

A

M E

N D

M E

N T

N O

/3

/2

A

M E

N D

M E

N T

N O

/2

/2

T

T

T

T T

T

T T

T T

T

T

T

T

T T

T

6 6.7 7 8 8.4 9

G

F.3

F

E

D.7

D

D.4

F.6

7.5 8.86.4 8.9

E.5

C.9

G.1

8.37.96.9

1F104A

1F231A

1F

A

1F

C

1F121A

1F229A

1F

A

1F112B

1F

A

14B8 14B8

14B8

4B8

4B8

4B8

4B8

20A3

20A3

1B8

4B8

13B8

20B6

3B8

1A6

1B8

3B8

4B8

4B8 20A6

20A3

1A6

1A8

1A8

4B8

2'

5'

2'

/4

7'

/4

4'

/4

/4 "9'

6' - 4" 14' - 0" 14' - 4"

2' - 0"

10' - 0" 10 3/8" 19' - 1 5/8" 1' - 2"

1B8

1F119A

1B8

4B8

1B8

1F118A

4B8

4B8

14B8

1F

B

4B8

1F102A

21A6

4B8

4B8

2B8

20A6

8' - 1 1/2" 5' - 6 1/2" 8' - 4" 6' - 0"

2' - 0"

CLR.

8' - 0" 2' - 0" 20' - 0" 1' - 6" 7' - 5 3/8" 9' - 0 5/8"

2' - 11"

1' - 0"

12' - 8" 16' - 4"

4"

13' - 8" 13' - 4"

20A3 20A3

20A3

20A3

MECHANICAL

1F113

A-403A

ELECTRICAL RM

1F118

MAIL RM

1F119

CORRIDOR

1F106

PC-1

1F231

SECURITY

1F230

ESS

1F234

BREAKROOM

1F237

PANTRY

1F238

ELEVATOR LOBBY

1F121

CONTROL CLST

1F228

TRANSITION

GROUP

1F229

GUARD STATION

1F103

VESTIBULE

1F100

LOBBY

1F101

INTERVIEW RM

1F104

STORAGE

1F105

WOMEN

1F117

MEN

1F116

3B8

3B8

20A620B3

1B8

1A8

1F

A

1F

A

1F109A

JAN

1F109

WOMENS

1F107

MENS

1F108

PRIVATE DINING

1F129

20B3

FITNESS

1F204

LOCKER RM

1F207

LOCKER RM

1F201

NIPR ROOM

1F102

1F100C

1F100D

ST1ST1

ST1

ST1

A-426

A-401

A-406

P10P10

P3

P3

P3

P10 P10

1' - 5"

9' - 0" 10' - 9"

REFER SHEET

/1 A-115

/1 A-112REFER SHEET /1 A-113REFER SHEET

REFER SHEET /1 A-119A/1 A-118REFER SHEET

A-404

REFER SHEET /1 A-115

P1

P1

P1 P1

ST1

P3

P3

ST1

ST1

ST1 P1 P1

P1

P1

1F100A

1F100B

P3

2'

8'

6'

1'

9" 1'

3' - 1" 13' - 8" 14' - 4" 10' - 0" 2' - 0" 20' - 0" 18' - 0" 2' - 0" 18' - 0" 2' - 0" 8' - 0" 3' - 4" 6' - 8"

A-200A

D.5

1F101B

1F101C

1F101D

1F101A

6B6

RA1

CR

CR & ABA

ABA

ABA

1F

A

1F

A

5 4

1F

B

1F

A

A-458

ABA

ELEV 3

ELEV 3

ELEV 2

ELEV 2

CORRIDOR

1F120

2'

/2

1/ 2"

1'

2'

2'

11' - 9"

P2

P2

A-550A

CR &

ABA

CR &

ABA

ST1 ST1

20A38

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

1. OPERABLE PARTITION WITH POCKET DOORS. MIN. STC 50

2. DUAL WATER COOLER WITH BOTTLE FILLER. ABA COMPLIANT

3. 10'-0" TALL WIRE MESH PARTITIONS

4. MOP SINK

5. MOP AND BROOM HOLDER

6. RECESSED ENTRANCE FLOOR GRID W/ DRAIN BELOW (SEE PLUMBING

DRAWINGS)

7. BOLLARDS WITH INTEGRATED ACCESS CONTROL (CR) AND ABA PUSH

BUTTON CONTROL (ABA) WHERE INDICATED AT EACH SIDE OF THE

BOLLARD ON PLAN. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION

8. ALL EXPOSED TO VIEW STRUCTURAL STEEL IN THIS ROOM ARE TO

RECEIVE A SPRAY-ON INTUMESCENT EPOXY COATING SYSTEM TO MEET

THE FIRE RESISTANCE REQUIREMENTS AS NOTED ON GI001 OF THE LIFE

SAFETY DRAWINGS. THE STEEL IN THESE AREAS SHALL ALSO MEET

ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) CATEGORY 3.

GENERAL NOTE:

ALL KEYED NOTES ARE TYPICAL. ALL NOTES MAY NOT BE REPRESENTED ON

EVERY SHEET.

GENERAL NOTES:

A. REFER TO AND COORDINATE WITH LIFE SAFETY PLANS FOR ALL

REQUIRED FIRE RATED AND SMOKE RATED BARRIER AND PARTITION

LOCATIONS. WHERE LIFE SAFETY PLANS SHOW FIRE RATED AND SMOKE

RATED BARRIER AND PARTITION LOCATIONS, ALL PENETRATIONS

THROUGH THOSE PARTITIONS SHALL BE PROTECTED WITH AN

APPROVED THROUGH PENETRATING ASSEMBLY FOR THE PARTITION

TYPE. PARTITIONS SHALL MEET THE REQUIREMENTS OF NFPA 101 FOR

THE TYPE OF RATING REQUIRED.

KEYED NOTES (DENOTED BY )X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

W F

-1 C

W F

-1 -R

-0

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

4 5 6A

7 8 9A

KEY PLAN

PLAN NORTH

C S

O F

P A

C K

A G

E

5/24/2021 9:12:33 AM

A-116A

S

T F

L O

O R

S

E C

T O

R

P L A

N

B

ID

O P

T

IO

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

1/8" = 1'-0"

1ST FLOOR - SECTOR 6 PLAN A

PLAN NORTH

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

A

M E

N D

M E

N T

N O

/3

/2

A

M E

N D

M E

N T

N O

/2

/2

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

1 2 2.3 3 3.6

D

C.5

C.3

C

A

1F

C

1F

A

1F

B

1F

K

1F127A

1F171B

1F

A

1F

B

1F

6J

1F125D

1F179A

1F182A

1F183A

1F184A

1F186A

3B8

1A8

4B8

4B8 4B8

4B8

4B8

12B8

13B8

4B8

4B8

4B8

4B8

7B6

7B6

7B6

13B8

4B8

13B8

5B8

1A8

20B3

20B3

7B6

0.5 1.7

C.7

C.6

C.4

B.5

B.4

B

1F

L

15' - 3" 4' - 2"

CLR.

5' - 9 1/2"

1' - 5 1/2"

12' - 0" 9' - 11" 16' - 11" 1' - 2" 1' - 4" 16' - 4" 6' - 10"

A-415

2'

1'

8'

1'

3/

4"

1F S

T

8'

/2

A-423

A-422

1F217D

1F

M

A-310

DN

UP

DN

6'

/2

1"

9'

1'

2'

8'

2'

3'

2'

1"

1'

1' - 3"

11' - 4"

1'

/4

/4

2' - 4"

REFER SHEET

/1 A-115

REFER SHEET

/1 A-114

1F127C

A-535

10' - 1" 15' - 3" 10' - 1"

1' - 4" 1' - 4"

10' - 8" 26' - 8"

1' - 4" 1' - 4"

18' - 3" 2' - 8"

1' - 4 1/2"

RA1

RA1

RA1

1' - 9" 1' - 3"

8' - 3"

/8

3'

/8

2'

1/

2"

2'

4'

/2

8'

/2

5'

1'

7'

1'

1'

/8

9'

2' - 0"

9' - 2" 11' - 4" 19' - 7" 16' - 2"

/2

1'

/2

1'

/8

2' - 6 1/4"

10' - 9 3/4"

1'

2'

1/ 2"

2' - 3 3/4" 15' - 0 1/4" 10' - 6" 9' - 2"

2' - 3" 2' - 0" 8' - 0"

2' - 0" 12' - 0" 23' - 0" 15' - 3" 1' - 8"

5'

1' - 3" 8' - 2 1/2" 1' - 9 1/2" 26' - 7" 9' - 9"

1' - 8"

2' - 0"

8' - 0"

2' - 0" 1' - 5"

25' - 1" 1' - 6"

1' - 6"

5' - 6" 15' - 3"

1' - 8"

1F219A

A-422

ST12

ST12

P1

P11

P11

P11

P11

P1

P1

P11

P1

P1

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1

P9

P11

P11

TEAM RM

1F182

J6 LAB

1F185

DIRECTOR

1F184

DEP DIR

1F183

J6 CONFERENCE

ROOM

1F186

MECHANICAL

1F210

IDF

1F211

MECHANICAL

1F180

ELEC

1F175

VEST

1F127

WORK ROOM

1F216

VTC ROOM

1F218

VTC ROOM

1F219

STAIR 3

ST3

J6

1F181

TEAM ROOM

1F179

MECHANICAL

1F171

SERVER ROOM B

1F174

CORRIDOR

1F126

CORRIDOR

1F125

13B8 4B8

4B8

20A6

20A6

2B8

3B8 14B8

4B8

4B8

4B8

13B8

4B8

5B8

20A6

4B814B8

20A3

14B8

14B8

14B8

20B3

20B3

20B3

20A620A6 20A6

4B8

13B8

21A3

13B8

13B8

4B8

20B3 20B3

20B3

4B8

4B8 4B8

20B3

4B8

5B8

CONCRETE STOOP,

REFER TO

STRUCTURAL

20A6 20A6

RA1

21A6

REFER SHEET

/1 A-118

MILLWORK, SEE

/3 I-507

1. OPERABLE PARTITION WITH POCKET DOORS. MIN. STC 50

2. DUAL WATER COOLER WITH BOTTLE FILLER. ABA COMPLIANT

3. 10'-0" TALL WIRE MESH PARTITIONS

4. MOP SINK

5. MOP AND BROOM HOLDER

6. RECESSED ENTRANCE FLOOR GRID W/ DRAIN BELOW (SEE PLUMBING

DRAWINGS)

7. BOLLARDS WITH INTEGRATED ACCESS CONTROL (CR) AND ABA PUSH

BUTTON CONTROL (ABA) WHERE INDICATED AT EACH SIDE OF THE

BOLLARD ON PLAN. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION

8. ALL EXPOSED TO VIEW STRUCTURAL STEEL IN THIS ROOM ARE TO

RECEIVE A SPRAY-ON INTUMESCENT EPOXY COATING SYSTEM TO MEET

THE FIRE RESISTANCE REQUIREMENTS AS NOTED ON GI001 OF THE LIFE

SAFETY DRAWINGS. THE STEEL IN THESE AREAS SHALL ALSO MEET

ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) CATEGORY 3.

GENERAL NOTE:

ALL KEYED NOTES ARE TYPICAL. ALL NOTES MAY NOT BE REPRESENTED ON

EVERY SHEET.

GENERAL NOTES:

A. REFER TO AND COORDINATE WITH LIFE SAFETY PLANS FOR ALL

REQUIRED FIRE RATED AND SMOKE RATED BARRIER AND PARTITION

LOCATIONS. WHERE LIFE SAFETY PLANS SHOW FIRE RATED AND SMOKE

RATED BARRIER AND PARTITION LOCATIONS, ALL PENETRATIONS

THROUGH THOSE PARTITIONS SHALL BE PROTECTED WITH AN

APPROVED THROUGH PENETRATING ASSEMBLY FOR THE PARTITION

TYPE. PARTITIONS SHALL MEET THE REQUIREMENTS OF NFPA 101 FOR

THE TYPE OF RATING REQUIRED.

KEYED NOTES (DENOTED BY )X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

-1 C

W F

-1 -R

-0

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

O F

P A

C K

A G

E

5/24/2021 9:12:40 AM

A-117

S

T F

L O

O R

S

E C

T O

R

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

PLAN NORTH

1/8" = 1'-0"

1ST FLOOR - SECTOR 7 PLAN

A

M E

N D

M E

N T

N O

/3

/2

A

M E

N D

M E

N T

N O

/2

/2

T

T

T

T

T

T

T

T

T

T

3.6 4 5 5.4 6

D

C.5

C.3

C

A

1F

C

1F

B

1F187A

1F217A

1F217B

1F

D

1F

E

1F

F

21A8

4B8

4B8

4B8

4B8

4B8

4B8

4B8

4B8

4B8

13B8

4B8

14B8

4B8 4B8

12B8

20A6

20A6

14B8

1F

P

1F

H

C.7

C.6

C.4

B.5

B.4

B

1F

L

6' - 10" 5' - 8" 9' - 10" 1' - 2" 32' - 6" 5' - 2"

1' - 2"

3' - 6" 37' - 2"

B.1

8'

2'

2'

3'

1"

1'

1'

1/ 4"

/4

1'

4'

/4

1F217D

1F128C

1F128B

1F

M

3'

0"

/4

/2

5' - 10"

2' - 4"

4' - 2"

1' - 0"

9 1/4"

3'

0"

/4

3'

2'

1/ 4"

/1 A-116

A-536

100' - 6"

9'

4'

4'

5'

3'

/4

3'

/4

8'

2'

1'

8'

A-206

2' - 8"

1' - 4 1/2"

14' - 2" 2' - 8" 37' - 4" 1' - 4" 3' - 6"

3' - 9 1/2"

RA1

A-546

7' - 6" 25' - 0" 7' - 6"

.0

150.00°

2' - 8"

1' - 4" 38' - 8" 3' - 6" 14' - 3" 11" 6' - 0" 4' - 6"

1' - 11"

8' - 9"

1' - 4"

1' - 8"

14' - 3" 19' - 2"

2' - 3"

10" 1' - 8" 1'

0"

2'

2'

/2

7'

1'

1'

7'

/4

5'

3/ 4"

1'

1'

4' - 7"

1' - 8"

5' - 4 1/2"

7 1/2"

7' - 5 3/4"

4" 1' - 1 1/4"

1' - 1 5/8"

2' - 8" 1' - 8" 73' - 0 1/2" 9 1/2" 16' - 3 1/2"

2' - 10 1/2"

2' - 9" 4"

/2

6'

/2

1"

1'

2'

8'

2'

1"

1'

1F219A

REFER SHEET

EDGE OF RAISED

PLATFORM

ST12

ST12

P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1

OPERATIONS

SOFTWARE

DEVELOPMENT

1F188

DEVELOPMENT

CENTER

1F189

MODELING /

SIMULATION

1F190

VTC ROOM

1F218

VTC ROOM

1F219

SHADOW OPS

FLOOR

1F217

FITNESS

STORAGE

1F205

MEN

1F209

TRAINING ROOM

1F195

JANITOR

1F191

CORRIDOR

1F126

CREW BRIEFING

RM

1F220

4B8

1B8

4B8

20A6

20A6

4B8

13B8

21A6

20A3

20B3

20A6

1A6

1A6

1A6

20B320B3

13B8

13B8

20B320B3

4B8

4B8

6B6

4B8

T Y

P .0

1'

/2

5'

/2

8'

2'

8'

BREAK AREA MILLWORK,

SEE /1 I-420

BREAK AREA

MILLWORK,

SEE /2 I-420

BREAK AREA

MILLWORK,

SEE /3 I-420

MILLWORK, SEE

/10 I-506

MILLWORK, SEE

/3 I-507

POCKET DOOR(S)

BY OPERABLE PARTITION

MFR, COLOR TO MATCH

SURROUNDING WALLS

VERIFY POCKET CLEAR

DIMENSIONS W/ MFR

14B8

13B8

21A3

1A64B8

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

1. OPERABLE PARTITION WITH POCKET DOORS. MIN. STC 50

2. DUAL WATER COOLER WITH BOTTLE FILLER. ABA COMPLIANT

3. 10'-0" TALL WIRE MESH PARTITIONS

4. MOP SINK

5. MOP AND BROOM HOLDER

6. RECESSED ENTRANCE FLOOR GRID W/ DRAIN BELOW (SEE PLUMBING

DRAWINGS)

7. BOLLARDS WITH INTEGRATED ACCESS CONTROL (CR) AND ABA PUSH

BUTTON CONTROL (ABA) WHERE INDICATED AT EACH SIDE OF THE

BOLLARD ON PLAN. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION

8. ALL EXPOSED TO VIEW STRUCTURAL STEEL IN THIS ROOM ARE TO

RECEIVE A SPRAY-ON INTUMESCENT EPOXY COATING SYSTEM TO MEET

THE FIRE RESISTANCE REQUIREMENTS AS NOTED ON GI001 OF THE LIFE

SAFETY DRAWINGS. THE STEEL IN THESE AREAS SHALL ALSO MEET

ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) CATEGORY 3.

GENERAL NOTE:

ALL KEYED NOTES ARE TYPICAL. ALL NOTES MAY NOT BE REPRESENTED ON

EVERY SHEET.

GENERAL NOTES:

A. REFER TO AND COORDINATE WITH LIFE SAFETY PLANS FOR ALL

REQUIRED FIRE RATED AND SMOKE RATED BARRIER AND PARTITION

LOCATIONS. WHERE LIFE SAFETY PLANS SHOW FIRE RATED AND SMOKE

RATED BARRIER AND PARTITION LOCATIONS, ALL PENETRATIONS

THROUGH THOSE PARTITIONS SHALL BE PROTECTED WITH AN

APPROVED THROUGH PENETRATING ASSEMBLY FOR THE PARTITION

TYPE. PARTITIONS SHALL MEET THE REQUIREMENTS OF NFPA 101 FOR

THE TYPE OF RATING REQUIRED.

KEYED NOTES (DENOTED BY )X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

-1 C

W F

-1 -R

-0

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

O F

P A

C K

A G

E

5/24/2021 9:12:46 AM

A-118

S

T F

L O

O R

S

E C

T O

R

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

1/8" = 1'-0"

1ST FLOOR - SECTOR 8 PLAN

PLAN NORTH

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

A

M E

N D

M E

N T

N O

/3

/2

A

M E

N D

M E

N T

N O

/2

/2

T

T

T

T

T

T

A-417

6 6.7 7 8 8.4 9

D

C.5

C.3

C

A

1F

A

1F

6G

7.5 8.8

1F

F

1F

D

4B8

4B8

4B8

4B8

4B8

4B8

4B8

1FST4

1F

H

6.4 8.9

C.7

C.6

C.4

B.5

B.4

B

1F126N

A-401

B.1

C.9

8.37.96.9

1F128C

1F128B

1F

B

1F

A

1F

A

1F209A 1F200A

UP

4' - 2"

7' - 0" 2' - 3"

1' - 1 1/2"

/1 A-116

A-536

2' - 10"

2'

2'

7'

4'

4'

5'

4'

6'

2'

1'

2' - 0"

7' - 0"

1' - 0"

2' - 0" 20' - 0" 18' - 0" 2' - 0" 18' - 0" 2' - 0" 8' - 0" 3' - 4" 6' - 8"

RA1

RA1

RA1

5' - 7 1/2"

4" 1' - 2"

6' - 11 1/2" 3' - 2"

3' - 9 1/4"

3' - 2"

3' - 9 1/4"

5' - 2"

10"

11 1/4" 2' - 0"

11' - 8 1/2" 6 1/4"

1' - 3"

12' - 1 3/4"

9 1/4"

12' - 0"

8 3/4"

9' - 9" 2' - 11"

11 1/4"

9' - 2"

10"

6" 9"

2'

/8

3'

/8

1'

1'

4'

/8

/8

2'

8'

/8

1'

/8

/8

4"

/8

1'

6"

9'

/8

1'

/8

7'

/2

/2

3'

/4

1'

/2

1'

1'

/4

1'

0"

3'

/8

5/

8" 1'

/4

3'

0"

3'

1'

/4

1'

/4

8'

/4

2'

1/

2"

/2

3'

0" 1'

1'

6'

3'

/4

3'

/4

/2

1'

3/

4"

1/ 4"

1' - 5 1/4"

1' - 5 1/4"

REFER SHEET

DN

P1

P1 P1

P1

P1

P1

P1

P1

P1

P1

P1

P1

P1

P1

P1

3' - 1" 1' - 8" 28' - 4" 7' - 2"

10"

1' - 6"

P1 P15

MDF

1F197

IDF

1F192

LOCKER RM

1F207

SHOWER

1F202

VEST

1F198

SHOWER

1F208

MEN

1F209

WOMEN

1F200

STAIR 4

ST4

ALCOVE

1F128

ELEC

1F203

4B8

1B8

1B8

21A6

1A8

20B3

20B3

20B3

1A6

1A6

1A6

20B320B3

20A3

1A8

1A8

20A3

20A3

20A3

20A3

20A3

20A3

20A3

20A3

20A3

CONCRETE STOOP,

REFER TO STRUCTURAL

BREAK AREA

MILLWORK,

SEE /3 I-420

MILLWORK,

SEE /2 I-507

5'

/2

XX

Room name

A101

SIM

XX

DETAIL NUMBER

SHEET NUMBER

ROOM NUMBER

DOOR TAG

RE: A-600 TO A-602

GRID BUBBLE

WALL TYPE TAG

RE: A-500 THRU A-503

ROOM TAG

SECTION TAG

DETAIL TAG

XX

FLOOR PLAN LEGEND

A101

SIM

SECTION NUMBER

RAISED ACCESS

FLOOR SYSTEM

PATTERN LEGEND

SECURED

BOUNDARY

XX

INSULATED PRECAST

WALL PANEL TAG

REFERENCE WALL

SECTION AND PANEL

ELEVATION SHEETS

FOR ADDITIONAL

INFORMATION

X FLOOR PLAN

KEYNOTE TAG

SHEET NUMBER

WINDOW TAG

RE: A-470 TO A-471

GENERAL NOTES:

A. NOT ALL TAGS AND/OR HATCH

PATTERNS ARE SHOWN ON

THIS SHEET.

ENTIRE ROOM TO

RECEIVE 400 LB/SF

RAISED ACCESS

FLOOR - ALL RAISED

ACCESS FLOORS NOT

TAGGED ARE 250LB/SF

RA1

SECTOR

MATCHLINES

1. OPERABLE PARTITION WITH POCKET DOORS. MIN. STC 50

2. DUAL WATER COOLER WITH BOTTLE FILLER. ABA COMPLIANT

3. 10'-0" TALL WIRE MESH PARTITIONS

4. MOP SINK

5. MOP AND BROOM HOLDER

6. RECESSED ENTRANCE FLOOR GRID W/ DRAIN BELOW…

This is the start of the file's text. The full file is on GovTribe.