CSOF_DRAWINGS_Volume 5_Fire-Plumbing.pdf

PDF 31 MB Posted

Attached to
Consolidated Space Operations Facility, Schriever AFB, Colorado
Solicitation number
W9128F20R0002
Issued by

About this file

This notice is for a solicitation for the construction of the Consolidated Space Operations Facility at Schriever Air Force Base in Colorado. The project will consist of constructing a two-story facility and one-story entry control facility in compliance with DoD, Air Force, and base design standards using local materials where cost effective. Facilities will be designed as permanent construction according to DoD Unified Facilities Criteria for general building requirements and high performance sustainable building standards. The project will also comply with DoD antiterrorism and force protection requirements and include cybersecurity measures for facility control systems. Offerors must be able to commence work within 10 days of notice to proceed and complete construction within 1400 calendar days, with liquidated damages for failure to meet the deadline. Performance and payment bonds will be required. The solicitation, drawings, and instructions to offerors are provided in the attached documents. The solicitation is open to both large and small businesses and is being conducted by the Department of the Army Corps of Engineers Omaha District.

View the file

Other files

File Type Posted
Am-0012_W9128F20R0002.pdf PDF
Am-0011_W9128F20R0002.pdf PDF
Am-0010_W9128F20R0002.pdf PDF
Am-0009_W9128F20R0002.pdf PDF
Am-0009_W9128F20R0002_Drawings-Reissued.pdf PDF
Am-0008_W9128F20R0002_Drawings_(Reissued).pdf PDF
Am-0008_W9128F20R0002.pdf PDF
CSOF Part 1_Modeling Files_90 Percent Corrected Download Instructions.pdf PDF
Am-0007_W9128F20R0002.pdf PDF
Modeling Files - 90 Percent Corrected Disclaimer.pdf PDF
Am-0004_W9128F20R0002.pdf PDF
CSOF Part 9_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 2_Modeling Files_90 Percent Corrected.zip ZIP file
ECP_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 10_Modeling Files_90 Percent Corrected.zip ZIP file
Am-0005_W9128F20R0002.pdf PDF
Am-0006_W9128F20R0002.pdf PDF
CSOF Part 1_Modeling Files_90 Percent Corrected.pdf PDF
CSOF Part 7_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 3_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 6_Modeling Files_90 Percent Corrected.zip ZIP file
Am-0003_W9128F20R0002.pdf PDF
CSOF Part 5_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 8_Modeling Files_90 Percent Corrected.zip ZIP file
CSOF Part 4_Modeling Files_90 Percent Corrected.zip ZIP file
Am-0002_W9128F20R0002_Drawings-(Revised).pdf PDF
W9128F20R0002_Am0002_Final_Div00_Specs_Drawings.pdf PDF
CSOF Virtual Site Visit_Attendee POCs_01Apr2021.pdf PDF
W9128F20R0002_Am0001_Final.pdf PDF
CSOF_DRAWINGS_Volume 1_LS-Civil-Landscape.pdf PDF
90-Percent-Corrected_V3-SPECS_W9128F20R0002_ECP.pdf PDF
CSOF_DRAWINGS_Volume 8_Comm-Security.pdf PDF
ECP_DRAWINGS.pdf PDF
CSOF_DRAWINGS_Volume 4_Interiors.pdf PDF
Div00_W9128F20R0002.pdf PDF
90-Percent-Corrected_V1-SPECS_W9128F20R0002_CSOF-General.pdf PDF
90-Percent-Corrected_V2-SPECS_W9128F20R0002_CSOF.pdf PDF
CSOF_DRAWINGS_Volume 7_Electrical.pdf PDF
CSOF_DRAWINGS_Volume 6_Process-Mechanical.pdf PDF
CSOF Site Photo Package compressed.pdf PDF
CSOF_DRAWINGS_Volume 3_Architectural.pdf PDF
CSOF_DRAWINGS_Volume 2_Structural.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

C S

O F

P

A C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/10/2021 9:50:23 AM

G-008

C O

V E

R S

H E

E T

V

O L U

M E

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

FIRE PROTECTION, PLUMBING

1616 CAPITAL AVENUE, #3300 OMAHA, NEBRASKA 68102

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

US Army Corps of Engineers ®

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

SOLICITATION NO.: W9128F20R0002

CONSTRUCTION CONTRACT NO.:

ISSUE DATE:

90% CORRECTED DESIGN

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

OMAHA DISTRICT

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/10/2021 9:50:23 AM

G-008

C O

V E

R S

H E

E T

V

O L U

M E

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

SCHRIEVER AFB, COLORADO

CONSOLIDATED SPACE OPERATIONS FACILITY

BLDG. NO. 750

03-12-2021

CSOF PACKAGE - VOLUME 5

BID OPTION 3D PERSPECTIVE

BASE BID 3D PERSPECTIVE

MECHANICAL

PLUMBINGARCHITECTURALSTRUCTURALCIVIL / LANDSCAPEFIRE PROTECTION

TELECOMMUNICATIONSELECTRICAL

DESIGNER SIGNATURE BLOCK

N

N

MECHANICAL ELECTRICAL

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/10/2021 9:50:28 AM

G-009

C S

O F

D

R A

W

IN

G I

N D

E X

V

O L U

M E

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

M D

A L L A

B A

T T

IS

T

A

T V

O N

F E

L D

T

T V

O N

F E

L D

T

J O

L S

O N

S H

-G

L E

N -3

-C

S O

F -A

.R

V T

SHT No SHEET NAME REV DATE

P-116A SANITARY AND VENT - FIRST FLOOR - SECTOR 6 - BID OPTION

P-117 SANITARY AND VENT - FIRST FLOOR - SECTOR 7

P-118 SANITARY AND VENT - FIRST FLOOR - SECTOR 8

P-119 SANITARY AND VENT - FIRST FLOOR - SECTOR 9

P-119A SANITARY AND VENT - FIRST FLOOR - SECTOR 9 - BID OPTION

P-120 OVERALL SANITARY AND VENT - SECOND FLOOR

P-120A OVERALL SANITARY AND VENT - SECOND FLOOR - BID OPTION

P-121 SANITARY AND VENT - SECOND FLOOR - SECTOR 1

P-122 SANITARY AND VENT - SECOND FLOOR - SECTOR 2

P-123 SANITARY AND VENT - SECOND FLOOR - SECTOR 3

P-124 SANITARY AND VENT - SECOND FLOOR - SECTOR 4

P-125 SANITARY AND VENT - SECOND FLOOR - SECTOR 5

P-126 SANITARY AND VENT - SECOND FLOOR - SECTOR 6

P-126A SANITARY AND VENT - SECOND FLOOR - SECTOR 6 - BID OPTION

P-127 SANITARY AND VENT - SECOND FLOOR - SECTOR 7

P-128 SANITARY AND VENT - SECOND FLOOR - SECTOR 8

P-129 SANITARY AND VENT - SECOND FLOOR - SECTOR 9

P-129A SANITARY AND VENT - SECOND FLOOR - SECTOR 9 - BID OPTION

P-130 OVERALL SANITARY AND VENT - ROOF

P-130A OVERALL SANITARY VENT - ROOF - BID OPTION

P-131 SANITARY AND VENT - ROOF - SECTOR 1

P-132 SANITARY AND VENT - ROOF - SECTOR 2

P-133 SANITARY AND VENT - ROOF - SECTOR 3

P-134 SANITARY AND VENT - ROOF - SECTOR 4

P-135 SANITARY AND VENT - ROOF - SECTOR 5

P-136 SANITARY AND VENT - ROOF - SECTOR 6

P-136A SANITARY AND VENT - ROOF - SECTOR 6 - BID OPTION

P-137 SANITARY AND VENT - ROOF - SECTOR 7

P-138 SANITARY AND VENT - ROOF - SECTOR 8

P-139 SANITARY AND VENT - ROOF - SECTOR 9

P-139A SANITARY AND VENT - ROOF - SECTOR 9 - BID OPTION

P-210 OVERALL DOMESTIC WATER - FIRST FLOOR

P-210A OVERALL DOMESTIC WATER - FIRST FLOOR - BID OPTION

P-211 DOMESTIC WATER - FIRST FLOOR - SECTOR 1

P-212 DOMESTIC WATER - FIRST FLOOR - SECTOR 2

P-213 DOMESTIC WATER - FIRST FLOOR - SECTOR 3

P-214 DOMESTIC WATER - FIRST FLOOR - SECTOR 4

P-215 DOMESTIC WATER - FIRST FLOOR - SECTOR 5

P-216 DOMESTIC WATER - FIRST FLOOR - SECTOR 6

P-216A DOMESTIC WATER - FIRST FLOOR - SECTOR 6 - BID OPTION

P-217 DOMESTIC WATER - FIRST FLOOR - SECTOR 7

P-218 DOMESTIC WATER - FIRST FLOOR - SECTOR 8

P-219 DOMESTIC WATER - FIRST FLOOR - SECTOR 9

P-219A DOMESITIC WATER PIPING - SECTOR 9 - BID OPTION

P-220 OVERALL DOMESTIC WATER - SECOND FLOOR

P-220A OVERALL DOMESTIC WATER - SECOND FLOOR - BID OPTION

P-221 DOMESTIC WATER - SECOND FLOOR - SECTOR 1

P-222 DOMESTIC WATER - SECOND FLOOR - SECTOR 2

P-223 DOMESTIC WATER - SECOND FLOOR - SECTOR 3

P-224 DOMESTIC WATER - SECOND FLOOR - SECTOR 4

P-225 DOMESTIC WATER - SECOND FLOOR - SECTOR 5

P-226 DOMESTIC WATER - SECOND FLOOR - SECTOR 6

P-226A DOMESTIC WATER - SECOND FLOOR - SECTOR 6 - BID OPTION

P-227 DOMESTIC WATER - SECOND FLOOR - SECTOR 7

P-228 DOMESTIC WATER - SECOND FLOOR - SECTOR 8

P-229 DOMESTIC WATER - SECOND FLOOR - SECTOR 9

P-229A DOMESTIC WATER - SECOND FLOOR - SECTOR 9 - BID OPTION

P-301 PLUMBING SECTIONS

P-401 ENLARGED DOMESTIC WATER PLANS

P-402 ENLARGED DOMESTIC WATER PLANS

P-403 ENLARGED DOMESTIC WATER PLANS

P-404A ENLARGED DOMESTIC WATER PLANS - BID OPTION

P-501 PLUMBING DETAILS

P-502 PLUMBING DETAILS

P-503 PLUMBING DETAILS

P-504 PLUMBING DETAILS

P-505 PLUMBING DETAILS

P-601 PLUMBING SCHEDULES

P-602 PLUMBING SCHEDULES

P-901 DWV RISER DIAGRAMS

P-902 DWV RISER DIAGRAMS

P-903 DOMESTIC WATER RISER DIAGRAMS

P-904 DOMESTIC WATER RISER DIAGRAMS

P-905 STORM DRAIN RISER DIAGRAMS - NORTH

P-906 STORM DRAIN RISER DIAGRAMS - SOUTH

P-907A DWV AND DOMESTIC WATER RISER - SECTOR 9 - BID OPTION

P-908A STORM DRAIN RISER DIAGRAMS - BID OPTION

Grand total: 146

SHT No SHEET NAME REV DATE

1100 - FIRE PROTECTION

FA001 FIRE ALARM LEGEND AND NOTES

FA100 1ST FLOOR IUC - COMPOSITE FIRE ALARM PLAN

FA101 2ND FLOOR IUC - COMPOSITE FIRE ALARM PLAN

FA110 1ST FLOOR - COMPOSITE FIRE ALARM PLAN

FA110A 1ST FLOOR - COMPOSITE FIRE ALARM PLAN - BID OPTION

FA111 1ST FLOOR - SECTOR 1 FIRE ALARM PLAN

FA112 1ST FLOOR - SECTOR 2 FIRE ALARM PLAN

FA113 1ST FLOOR - SECTOR 3 FIRE ALARM PLAN

FA114 1ST FLOOR - SECTOR 4 FIRE ALARM PLAN

FA115 1ST FLOOR - SECTOR 5 FIRE ALARM PLAN

FA116 1ST FLOOR - SECTOR 6 FIRE ALARM PLAN

FA116A 1ST FLOOR - SECTOR 6 FIRE ALARM PLAN - BID OPTION

FA117 1ST FLOOR - SECTOR 7 FIRE ALARM PLAN

FA118 1ST FLOOR - SECTOR 8 FIRE ALARM PLAN

FA119 1ST FLOOR - SECTOR 9 FIRE ALARM PLAN

FA119A 1ST FLOOR - SECTOR 9 FIRE ALARM PLAN - BID OPTION

FA120 2ND FLOOR - COMPOSITE FIRE ALARM PLAN

FA120A 2ND FLOOR - COMPOSITE FIRE ALARM PLAN - BID OPTION

FA121 2ND FLOOR - SECTOR 1 FIRE ALARM PLAN

FA122 2ND FLOOR - SECTOR 2 FIRE ALARM PLAN

FA123 2ND FLOOR - SECTOR 3 FIRE ALARM PLAN

FA124 2ND FLOOR - SECTOR 4 FIRE ALARM PLAN

FA125 2ND FLOOR - SECTOR 5 FIRE ALARM PLAN

FA126 2ND FLOOR - SECTOR 6 FIRE ALARM PLAN

FA126A 2ND FLOOR - SECTOR 6 FIRE ALARM PLAN - BID OPTION

FA127 2ND FLOOR - SECTOR 7 FIRE ALARM PLAN

FA128 2ND FLOOR - SECTOR 8 FIRE ALARM PLAN

FA129 2ND FLOOR - SECTOR 9 FIRE ALARM PLAN

FA129A 2ND FLOOR - SECTOR 9 FIRE ALARM PLAN - BID OPTION

FA600 TYPICAL FIRE ALARM & MNS RISER DIAGRAM

FA601 FIRE ALARM & MNS NOTIFICATION INPUT/OUTPUT MATRIX

FX001 FIRE SUPPRESSION SYSTEMS GENERAL NOTES AND DETAILS

FX100 1ST FLOOR IUC - COMPOSITE FIRE SUPPRESSION PLAN

FX101 2ND FLOOR IUC - COMPOSITE FIRE SUPPRESSION PLAN

FX110 1ST FLOOR - COMPOSITE FIRE SUPPRESSION PLAN

FX110A 1ST FLOOR - COMPOSITE FIRE SUPPRESSION PLAN - BID OPTION

FX111 1ST FLOOR - SECTOR 1, 2, 3, 4, 5, & 6 FIRE SUPPRESSION PLAN

FX112 1ST FLOOR - SECTOR 7, 8 & 9 FIRE SUPPRESSION PLAN

FX113 1ST FLOOR - SECTOR 6 & 9 FIRE SUPPRESSION PLAN - BID OPTION

FX120 2ND FLOOR - COMPOSITE FIRE SUPPRESSION PLAN

FX120A 2ND FLOOR - COMPOSITE FIRE SUPPRESSION PLAN - BID OPTION

FX121 2ND FLOOR - SECTOR 1, 2, 3, 4, 5, & 6 FIRE SUPPRESSION PLAN

FX122 2ND FLOOR - SECTOR 7, 8 & 9 FIRE SUPPRESSION PLAN

FX123 2ND FLOOR - SECTOR 6 & 9 FIRE SUPPRESSION PLAN - BID OPTION

FX401 ENLARGED FIRE PROTECTION PLAN

FX501 FIRE SUPPRESSION SYSTEM DETAILS

FX600 FIRE SUPPRESSION SYSTEM DIAGRAM

1200 - PLUMBING

P-001 LEGEND, ABBREVIATIONS, & NOTES

P-100 OVERALL SANITARY AND VENT - UNDERGROUND

P-100A OVERALL SANITARY AND VENT - UNDERGROUND - BID OPTION

P-101 SANITARY AND VENT - UNDERGROUND - SECTOR 1

P-102 SANITARY AND VENT - UNDERGROUND - SECTOR 2

P-103 SANITARY AND VENT - UNDERGROUND - SECTOR 3

P-104 SANITARY AND VENT - UNDERGROUND - SECTOR 4

P-105 SANITARY AND VENT - UNDERGROUND - SECTOR 5

P-106 SANITARY AND VENT - UNDERGROUND - SECTOR 6

P-106A SANITARY AND VENT - UNDERGROUND - SECTOR 6 - BID OPTION

P-107 SANITARY AND VENT - UNDERGROUND - SECTOR 7

P-108 SANITARY AND VENT - UNDERGROUND - SECTOR 8

P-109 SANITARY AND VENT - UNDERGROUND - SECTOR 9

P-109A SANITARY AND VENT - UNDERGROUND - SECTOR 9 - BID OPTION

P-110 OVERALL SANITARY AND VENT - FIRST FLOOR

P-110A OVERALL SANITARY AND VENT - FIRST FLOOR - BID OPTION

P-111 SANITARY AND VENT - FIRST FLOOR - SECTOR 1

P-112 SANITARY AND VENT - FIRST FLOOR - SECTOR 2

P-113 SANITARY AND VENT - FIRST FLOOR - SECTOR 3

P-114 SANITARY AND VENT - FIRST FLOOR - SECTOR 4

P-115 SANITARY AND VENT - FIRST FLOOR - SECTOR 5

P-116 SANITARY AND VENT - FIRST FLOOR - SECTOR 6

SHT No SHEET NAME REV DATE

0000 - GENERAL

G-008 COVER SHEET - VOLUME 5

G-009 CSOF - DRAWING INDEX - VOLUME 5

Grand total: 2

ABBREVIATIONS

WEATHER PROOF

FIRE ALARM

MASS NOTIFICATION SYSTEM

UNIFIED FACILITIES CRITERIA

WP

FA

MNS

UFC

DIRECT DIGITAL CONTROLSDDC

FIRE ALARM / MASS NOTIFICATION CONTROL UNITFACU

BOOSTER POWER SUPPLYBPS

FIRE ALARM ANNUNCIATOR FAA

SURGE PROTECTION DEVICESPD

PRESSURE SWITCHPS

POWER SUPPLY DISTRIBUTION PANELPSDP

LOCAL OPERATORS CONSOLELOC

REMOTE TEST STATIONRTS

MECHANICAL JOINTMJ

UNDERGROUND UG

POST INDICATOR VALVEPIV

POWER TRANSFER SWITCH CABINETPTSC

ANTI-TERRORISM AND FORCE PROTECTION ATFP

GENERAL NOTES:

1. PROJECT ENTAILS PROVIDING A NEW FIRE ALARM AND MASS NOTIFICATION SYSTEM FOR THE CONSOLIDATED SPACE OPERATIONS FACILITY (CSOF). NEW EQUIPMENT AND INSTALLATION METHODS SHALL BE IN COMPLIANCE WITH, BUT NOT LIMITED TO, THE UNIFIED FACILITIES CRITERIA, NFPA 70, 2020 EDITION; NFPA 72, 2019 EDITION AND; NFPA 90A, 2018

EDITION.

2. ALL INSTALLATION MATERIALS SHALL BE PROVIDED AS REQUIRED IN ORDER TO PROVIDE A CODE COMPLIANT

INSTALLATION OF A FULLY FUNCTIONAL AND OPERATIONAL SYSTEM.

3. SYSTEM WIRING SHALL BE CLASS B IN CONDUIT INSTALLED PER NFPA 70 AND NFPA 72 AND COLORED OR PROPERLY

IDENTIFIED.

4. ALL FIRE ALARM COMPONENTS SHALL BE U.L. LISTED OR FM APPROVED.

5. CONTRACTOR SHALL MAKE ALL INSIDE FIBER CONNECTIONS BETWEEN THE NEW FA / MN CONTROL PANEL(S) AND THE

NEW FIBER BACKBONE PROVIDED IN THE COMMUNICATIONS ROOM.

6. SPEAKERS AND VISUAL NOTIFICATION SHALL BE PROVIDED THROUGHOUT THE BUILDING FOR VOICE INTELLIGIBILITY

AND OCCUPANT NOTIFICATION. EXTERIOR SPEAKERS SHALL BE PROVIDED IN PUBLIC AREAS AND ANY AREAS

COMMONLY USED BY OCCUPANTS.

7. VISUAL NOTIFICATION SHALL BE PROVIDED IN ALL EMPLOYEE WORK, COMMON, AND PUBLIC AREAS.

8. MANUAL PULL STATIONS SHALL BE PROVIDED AT ALL BUILDING EXTERIOR DOOR AND ENTRANCE TO RATED STAIR

ENCLOSURES AND SHALL BE EASILY ACCESSIBLE, UNOBSTRUCTED, AND VISIBLE.

9. INTELLIGIBILITY OF CONTRACTOR’S AUDIO SYSTEM DESIGN WILL BE VERIFIED BY THE QUANTITATIVE INTELLIGIBILITY

TESTING DESCRIBED IN THE SPECIFICATIONS. IF THE TESTS FAIL TO SATISFY THE INDICATED MINIMUM CIS VALUES, THE CONTRACTOR MUST MODIFY THE SYSTEM AS NECESSARY TO SATISFY THE INTELLIGIBILITY CRITERIA; THE CONTRACTOR MUST PROVIDE ALL NECESSARY MODIFICATIONS AT NO ADDITIONAL COST TO THE OWNER. THE CONTRACTOR IS ENCOURAGED, BUT NOT REQUIRED, TO PERFORM INTELLIGIBILITY MODELING TO VALIDATE THE LAYOUT OF THEIR PROPOSED SPEAKERS, SPEAKER TAP SETTINGS, AND SPEAKER LAYOUT TO REDUCE THE RISK OF

CHANGES AFTER TESTING, PARTICULARLY IN HARD-SURFACED SPACES.

10. ALL JUNCTION, TERMINAL, MANUAL PULL BOXES, AND COVERS SHALL BE PAINTED RED AND SHALL BE IDENTIFIED WITH

ENGRAVED LABELS BY THE ZONE AND CIRCUIT THAT IT RESIDES ON.

11. ALL MANUAL FIRE ALARM PULL STATIONS TO BE INSTALLED WITHIN 5 FEET FROM THE ENTRANCE TO AN EXIT.

12. WIRE NUTS ARE PROHIBITED.

13. PROVIDE KEYED RESET SWITCHES WHERE DUCT DETECTORS ARE LOCATED OVER 7 FEET AFF. FIELD LOCATE

SWITCHES AS SHOWN ON DRAWINGS.

14. INSTALLING CONTRACTOR SHALL COORDINATE INSTALLATION WITH OTHER TRADES.

15. THE CANDELA INTENSITY AND SPACING SHOWN ON THE PLANS IS INTENDED TO MEET THE INTENSITY SPACING

REQUIREMENTS OF NFPA 72. IT IS THE INSTALLING CONTRACTORS RESPONSIBILITY TO INCREASE THE REQUIRED CANDELA AS REQUIRED TO MEET THE INTENSITY SPACING REQUIREMENTS OF NFPA 72 OR PROVIDE ADDITIONAL

STROBES TO MEET THE SPACING REQUIREMENTS.

16. LOC'S SHALL BE RECESSED MOUNTED NOT TO PROTRUDE MORE THAN 4 INCHES FROM THE WALL AND SHALL BE

MOUNTED WITH ANY OPERATING BUTTON OR DEVICE NO MORE THAN 48" AFF.

17. LOCATE LOC'S TO AVOID FEEDBACK FROM ADJACENT SPEAKERS. IF SUITABLE LOCATION CANNOT BE FOUND, PROGRAM

TO TURN OFF ADJACENT SPEAKERS DURING LOC MICROPHONE USE.

18. THE FIRE ALARM AND MASS NOTIFICATION POWER SUPPLY, AND NETWORK FIRE ALARM PANEL LOCATIONS SHOWN ON THE DRAWINGS ARE TO BE USED FOR IDENTIFYING WHERE THESE PANELS SHALL BE LOCATED. THE CORRECT NUMBER OF PANELS REQUIRED FOR PROPER SYSTEM OPERATION SHALL BE DETERMINED BY THE FIRE ALARM CONTRACTOR.

19. PENETRATIONS OF FIRE ALARM EQUIPMENT IN SECURE AREAS SHALL COMPLY WITH IC TECH SPEC ICD/ICS 705 AND

RELATED DOCUMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR WALL TYPES.

20. COORDINATE SPEAKER LOCATIONS WITH LOC IN ORDER TO PREVENT FEEDBACK.

21. INSTALL SURGE PROTECTION DEVICES EVERYWHERE FIRE ALARM WIRING ENTERS AND EXITS THE BUILDING.

22. PROVIDE SMOKE DETECTION AT EACH POWER EXTENDER PANEL.

23. DUCT SMOKE DETECTORS SHALL BE PROVIDED IN ALL HVAC MAIN SUPPLY AND RETURN DUCTS WHERE REQUIRED BY

NFPA 90A, AND SHALL HAVE AUXILIARY CONTACTS TO PROVIDE CONTROL, INTERLOCK, AND SHUTDOWN FUNCTIONS OF THE HVAC SYSTEMS. DETECTORS SHALL BE POWERED BY THE FIRE ALARM/MASS NOTIFICATION CONTROL PANEL.

24. EMERGENCY VISUAL TEXT SIGNS SHALL BE COORDINATED WITH THE EXIT SIGNS. WHERE EXIST SIGNS ARE IN CONFLICT WITH LOCATIONS WHERE EMERGENCY VISUAL TEXT SIGNS ARE REQUIRED, THE EMERGENCY VISUAL TEXT SIGNS

SHALL BE INSTALLED ADJACENT OR ABOVE THE EXIT SIGNS.

25. REFER TO GENERAL NOTE G.5 ON SHEET S-005 FOR ANY STRUCTURAL COORDINATION.

ELEVATOR NOTES:

1. THE ELEVATORS ARE DESIGNED TO COMPLY WITH THE REQUIREMENTS OF UFC 3-600-01 AND NFPA 13. HOWEVER, THE LOCAL JURISDICTION WILL INSPECT THE ELEVATORS AND LOCAL CODES SHALL ALSO PREVAIL.

2. UFC 3-600-01 REQUIRES SHUNT TRIP BY ACTIVATION OF FLOW SWITCH. LOCAL CODES MAY REQUIRE SHUNT TRIP TO BE PROVIDED BY ACTIVATION OF HEAT DETECTION. THE INSTALLATION SHALL COMPLY WITH BOTH DESIGN

REQUIREMENTS.

3. THE ELEVATORS ARE MACHINE ROOMLESS ELECTRIC TRACTION ELEVATORS. THE ELEVATORS MAY OR MAY NOT BE EQUIPPED WITH A COMBUSTIBLE CABLE DEPENDING ON THE ELEVATOR MANUFACTURER SELECTED.

4. THE BASE BID SHALL INCLUDE FOR A WORSE CASE SCENARIO ASSUMING A COMBUSTIBLE CABLE, COMPLIANCE WITH

UFC 3-600-01, NFPA 13, AND THE LOCAL ELEVATOR INSPECTOR'S REQUIREMENTS.

5. FOR BIDDING PURPOSES, PROVIDE THE DEVICES SHOWN ON THE CONTRACT DRAWINGS AND PROVIDE THE ADDITIONAL

DEVICES:

A. PROVIDE A SPRINKLER AT THE TOP OF THE ELEVATOR HOISTWAY WITH FLOW SWITCH, BUTTERFLY VALVE WITH

TAMPER SWITCH, CHECK VALVE, AND TESTING ASSEMBLY/DRAIN. THE FLOW SWITCH SHALL SHUNT TRIP THE ELEVATOR BY DIRECT CONNECTION FROM THE WATERFLOW SWITCH TO THE SHUNT TRIP BREAKER.

WATERFLOW SWITCH MUST HAVE NO TIME DELAY

B. PROVIDE A SPRINKLER IN THE ELEVATOR PIT WITH FLOW SWITCH AND BUTTERFLY VALVE WITH TAMPER SWITCH.

ACTUATION OF SPRINKLER IN PIT SHALL NOT DISCONNECT POWER TO THE ELEVATOR.

6. THE FINAL ELEVATOR DESIGN SHALL BE FINALIZED WITH THE AHJ AND ELEVATOR INSPECTOR. IF A NON-COMBUSTIBLE CABLE AND NON-COMBUSTIBLE ELECTRIC TRACTION ELEVATOR IS PROVIDED, THE ELEVATOR HOISTWAY AND PIT SHALL BE DESIGNED IN ACCORDANCE WITH UFC 3-600-01 TABLE 4-1 AND FIGURE 4-2 FOR ELECTRIC TRACTION ELEVATORS AND ALL FIRE PROTECTION ELEMENTS SHALL BE REMOVED FROM THE ELEVATOR HOISTWAY AND PIT.

#CD WALL MOUNTED FIRE ALARM / MASS NOTIFICATION SPEAKER STROBE

(CANDELA SHOWN ON PLANS)

CEILING MOUNTED FIRE ALARM / MASS NOTIFICATION SPEAKER

STROBE (CANDELA SHOWN ON PLANS)

CEILING MOUNTED FIRE ALARM / MASS NOTIFICATION STROBE ONLY

(CANDELA SHOWN ON PLANS)

WALL MOUNTED FIRE ALARM / MASS NOTIFICATION SPEAKER

CEILING MOUNTED FIRE ALARM / MASS NOTIFICATION SPEAKER

ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR

ADDRESSABLE CONTROL MODULE (SUPERVISED OUTPUTS)

ADDRESSABLE MONITOR MODULE

ADDRESSABLE RELAY MODULE (NON-SUPERVISED OUTPUTS)

MULTI-VOLTAGE COIL ENERGIZED RELAY

ADDRESSABLE MANUAL PULL STATION

ADDRESSABLE DUCT SMOKE DETECTOR; XX DESIGNATES THE UNIT

FIRE SPRINKLER TAMPER SWITCH

FIRE SPRINKLER FLOW SWITCH

EMERGENCY TEXT SIGN

DUCT SMOKE DETECTOR KEYED REMOTE TEST STATION

24 V DOOR HOLDER

CARBON MONOXIDE DETECTOR

ELEVATOR CONTROLS: INCLUDES RELAYS FOR; ELEVATOR SHUNT,

ELEVATOR PRIMARY FLOOR RECALL, ELEVATOR ALT. FLOOR RECALL,

FIRE HAT FLASH, AND FIRE HAT SOLID.

FIBER INTERFACE

#CD

#CD

FIRE ALARM OR MNS PANEL. TYPE AS INDICATED ON PLANS. PANEL

ABBREVIATIONS AS FOLLOWS:

FACU - FIRE ALARM AND MASS NOTIFICATION CONTROL UNIT

AMP - AUDIO EVACUATION AMPLIFIER PANEL

TRANS - TRANSCEIVER

BATT - BATTERY CABINET

FAPX - FIRE ALARM POWER EXTENDER PANEL

LOC - LOCAL OPERATORS CONSOLE

ANN - REMOTE ANNUNCIATOR

AASD - AIR ASPIRATING SMOKE DETECTOR

SMK-OVRD - SMOKE CONTROL OVERRIDE PANEL

SMK-MAP - SMOKE COMPARTMENT MAP

FIRE ALARM / MASS NOTIFICATION SYMBOLS AND LEGEND:

CM

MM

RM

MR

C

C

S

S

P

F

VS

WF

BACKFLOW PREVENTERBFP

ET

K

EXPLOSION PROOFEX

xx

CO

EC

FI

NOTES:

A. VERIFY EXACT MOUNTING HEIGHTS WITH PROJECT REQUIREMENTS. DEVICES

MAY OR MAY NOT APPLY TO THIS PROJECT. REFER TO PLANS.

B. ALL NEW DEVICES SHALL BE INSTALLED ACCORDING TO THE MOUNTING

HEIGHTS INDICATED U.N.O.

AUDIBLE /

VISUAL UNIT

VISUAL

ONLY UNIT

MANUAL PULL

STATION

TOP OF

PULL

STATION

HANDLE

FINISHED FLOOR

AUDIBLE

ONLY UNIT

M

IN

M

IN

EMERGENCY

TEXT SIGN

PULL DOWN

FIRE ALARM

M

A X

M

A X

M A

X

M

IN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:02:46 PM

FA001

F

IR

E A

L A

R M

L E

G E

N D

A N

D N

O T

E S

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

1/8" = 1'-0"1

FIRE ALARM MOUNTING HEIGHT DETAIL

C

S

C

S

C

C

S

C

S

C

C

S

C

C

S

C

C

S

C C

S

C

S

C

S

C C

S

C

S

C

S

C

C C

S

C

S

C

S

C C

S

C

S

C

S

C

C

C

S

C

S

C

S

C

C

S

C

S

C

LOC

LOC

LOC

LOC

FAPX

II

HH

G.7G.7

GG

F.3F.3

FF

EE

D.7D.7

DD

C.5C.5

C.3C.3

CC

0.5

0.5

2.3

2.3

3.6

3.6

5.4

5.4

6.7

6.7

7.5

7.5

8.4

8.4

8.8

8.8

AA

BB

STAIR 2

ST2

STAIR 1

ST1

STAIR 3

ST3

STAIR 4

ST4

H.6H.6

15cd

15cd

15cd

15cd

15cd

15cd

15cd 15cd

15cd

15cd15cd

15cd

1ST FLOOR IUC

1B101

1ST FLOOR IUC

1B102

1ST FLOOR IUC

1B103

1ST FLOOR IUC

1B100

15cd

15cd

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:02:49 PM

FA100

S

T F

L O

O R

I U

C

C O

M P

O S

IT

E

IR

E

A L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 3/64" = 1'-0"

16' 8' 0' 16' 48'32'

3/64" = 1'-0"1

1ST FLOOR IUC - COMPOSITE FIRE ALARM PLAN

F

F

C

C

S

C

S

C

S

C

S

C

S

C

C

S

C

S

C

S

C

C

S

C C

S

C

S

C

S C C

S

C

S

C

S

C

C C

S

C

S

C

S

C C

S

C

S

C

S

C

C

C

S

C

S

C

S

C

C

S

C

S

C

LOC

LOC

LOC

LOC

FAPX

JJ

II

HH

G.7G.7

G.5G.5

GG

F.6F.6

F.3F.3

FF

EE

D.7D.7

D.4D.4

DD

C.5C.5

C.3C.3

CC

0.5

0.5

2.3

2.3

3.6

3.6

5.4

5.4

6.7

6.7

7.5

7.5

8.4

8.4

8.8

8.8

AA

BB

STAIR 1

ST1

STAIR 2

ST2

STAIR 3

ST3

STAIR 4

ST4

H.6H.6

15cd

15cd

15cd 15cd

15cd

15cd

15cd

15cd

15cd15cd

15cd

15cd

2ND FLOOR IUC

2B102

2ND FLOOR IUC

2B103

2ND FLOOR IUC

2B101

2ND FLOOR IUC

2B100

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:02:53 PM

FA101

N

D F

L O

O R

I U

C

C O

M P

O S

E

A L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 3/64" = 1'-0"

16' 8' 0' 16' 48'32'

2ND FLOOR IUC - COMPOSITE FIRE ALARM PLAN

L

C

L O C

LOC

LOC

FACU

FACU

LOC

JJ

II

HH

GG

FF

EE

DD

CC

0.5

0.5

2.3

2.3

3.6

3.6

5.4

5.4

6.7

6.7

7.5

7.5

8.4

8.4

AA

BB

STAIR 1

ST1

STAIR 2

ST2

STAIR 5

ST5

STAIR 6

ST6

STAIR 4

ST4

STAIR 3

ST3

OPEN ABOVE

OPEN ABOVE

H.6H.6

FAPX FAPX FAPX

FAPX FAPX FAPX

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:02:59 PM

FA110

S

T F

L O

O R

C

O M

P O

S

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

3/64" = 1'-0"1

1ST FLOOR - COMPOSITE FIRE ALARM PLAN

SCALE IN FEET - 3/64" = 1'-0"

16' 8' 0' 16' 48'32'

L

C

L O C

LOC

LOC

LOC

FACU

FACU

LOC

F

F

F

FAPX

JJ

II

HH

GG

FF

EE

DD

CC

0.5

0.5

2.3

2.3

3.6

3.6

5.4

5.4

6.7

6.7

7.5

7.5

8.4

8.4

AA

BB

OPEN ABOVE

OPEN ABOVE

H.6H.6

FAPX FAPX FAPX

FAPX FAPX FAPX

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

4 5 6A

7 8 9A

KEY PLAN

PLAN NORTH

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:07 PM

FA110A

S

T F

L O

O R

C

O M

P O

S

IT

E F

IR

E

A L A

R M

P L

N

B

ID

O

P T

IO

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

3/64" = 1'-0"1

1ST FLOOR - COMPOSITE FIRE ALARM PLAN - BID OPTION

SCALE IN FEET - 3/64" = 1'-0"

16' 8' 0' 16' 48'32'

C C

S

C

S

F

F F

F

F

C

S

SS

S

S

S

S

S S

S

C

C

ET

LOC

CC

K

FACU

F

C

S

C

S

S

P P

S

F

FAPXFAPXFAPX

JJ

II

HH

G.7G.7

G.5G.5

0.5

0.5

2.3

2.3

3.6

3.6

MECHANICAL

1F254

IDF

1F253

VEST

1F124

ELEC

1F170

MDF

1F143

MECHANICAL "A"

1F148

VTC ROOM

1F240

STAIR 1

ST1

UPS B

1F140

UPS A

1F141

ELECTRICAL "A"

1F146

ELECTRICAL "B"

1F145

BATTERY RM

1F144

MECHANICAL "B"

1F147

ELECTRICAL

1F142

A/V

1F236A

15cd

15cd

WP

WPWP

WP

75cd

75cd

75cd

15cd

30cd

15cd

MECHANICAL

1F171

C O

R R

ID

O

R

1F

CORRIDOR

1F122

AHU-102

RETURN

AHU-102

SUPPLY

75cd75cd

AHU-102

/1 FA112

/1 FA112

/1 FA114

H.6H.6

ELECTRICAL

1F142A

/1 FA112

/1 FA115/1 FA114

75cd

75cd

CM

FOR DOOR

HOLDER RELEASE

MM

MM

WF

VS

MM

MM

WF

VS

MM

MM

WF

VS

FOR BATTERY

ROOM SPRINKLER

SUBZONE

FOR UPS A ROOM

SPRINKLER SUBZONE FOR UPS B ROOM

SPRINKLER SUBZONE

CORRIDOR

1F122A

75cd

/1 FA114

F A

RM

FOR EMERGENCY LIGHT

ACTIVATION. REFER TO

SHEET EP401 FOR LCP1

PANEL LOCATION

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:10 PM

FA111

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

1/8" = 1'-0"1

1ST FLOOR - SECTOR 1 FIRE ALARM PLAN

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

KEYED NOTES :

1. THIS FACU SHALL SERVE THE SECURE SPACE.

C C

S

C

S

C

S

F

S

C

C

C

C

CC

C

ET

S

II

HH

G.7G.7

G.5G.5

GG

3.6

3.6

5.4

5.4

ST-2

1F239

RECYCLING

1F135

CORRIDOR

1F122

NSDC OPS FLOOR

1F236

WOMEN

1F149

SHIPPING/RECEIVING

1F131

STORAGE

1F133

JAN.

1F137

VEST

1F132

STORAGE

1F134

NURSING MOTHER

1F136

15cd

WP

30cd

30cd

30cd

30cd

30cd30cd

15cd

30cd 60cd

30cd

75cd 75cd

MEN

1F150

H.6H.6

/1 FA111

/1 FA115/1 FA114 /1 FA115

/1 FA113

/1 FA116

F A

F A

NSDC OPS FLOOR

1F236

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:12 PM

FA112

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1ST FLOOR - SECTOR 2 FIRE ALARM PLAN

C

S

C

F

F

F

S

S

C

C C

S

C

C C

S

C

S

C

C C

S

C

S

C

S

C

S

C

P

C

C

ET

ET

L O C

K

C

F

S

CO

CO

C

S

S

II

HH

G.7G.7

G.5G.5

GG

6.7

6.7

7.5

7.5

8.4

8.4

8.8

8.8

ST-1

1F232

OFFICE

1F233

IDF

1F130

DINING

1F110

SECURITY

1F230

VESTIBULE

1F123STAIR 2

ST2

SERVICE ELEVATOR

ELEV 1

MECHANICAL

1F111

MENS

1F108

PRIVATE DINING

1F129

15cd

15cd

15cd

WP

WP

15cd

75cd 75cd

135cd 135cd

75cd 75cd

15cd 75cd

15cd

CORRIDOR

1F122

C O

R R

ID

O

R

1F

AHU-101

SUPPLY

AHU-101

RETURN

WATERFLOW HORN/STROBE.

W/"WATERFLOW" SIGNAGE

110cd

WP

AHU-101

H.6H.6

WF

VS

MM

MM

WF

VS

MM

MM

BFP

WP-1

WP-2

WP-3

WP-4

WP-5

WF

VS

MM

MM

WF

VS

MM

MM

WF

VS

MM

MM

WF

VS

MM

MM

WP-6

WP-7

WP-8

WF

VS

MM

MM

WF

VS

MM

MM

WF

VS

MM

MM

BFP

TEST

VSMM

/1 FA112

/1 FA115 /1 FA116

DRY STORAGE

1F110E

COOLER

1F110C

FREEZER

1F110D

15cd

F A

/1 FA116

KITCHEN / PREP

1F110A

MM MM

MONITORING MODULES

PROVIDED FOR KITCHEN

HOOD SUPPRESSION SYSTEM

15cd

WP

WP

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:14 PM

FA113

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1/8" = 1'-0"1

1ST FLOOR - SECTOR 3 FIRE ALARM PLAN

KEYED NOTES :

1. TWO 1" CONDUITS PER EACH, ONE FOR TAMPER SWITCH ON PIV

AND TWO FOR A/V DEVICE FOR FDC.

2. SPEAKER MOUNTED INSIDE COOLER DOOR.

CP

P

C

C

C

S

C

S

C

C

S

C

S

C

S

C

C

S

C

S

S

C

C

C

S

C

C

C

S

C

C

C

C

C

C

C

C

C

C

C

C

C

C

S

C

C

C

C

S

C

C

ET

F.6F.6

D.7D.7

D.4D.4

DD

0.5

0.5

2.3

2.3

3.6

3.6

HELP DESK

1F225

BREAKOUT

1F247

WORK ROOM 2

1F249

WORK ROOM 1

1F248 VTC ROOM

1F241

VTC ROOM

1F242

BREAKOUT

1F213

WORK ROOM

1F215

WORK ROOM

1F216

VTC ROOM

1F224

VTC ROOM

1F218

TOILET

1F250

TOILET

1F251

TOILET

1F252

MECHANICAL

1F171

SERVER ROOM A

1F172

SERVER ENTRY

1F173

SERVER ROOM B

1F174

ELEV 4

ELEV 4

ELEVATOR LOBBY

1F212

C O

R R

ID

O

R

1F

CONTROL CLST

1F227

A/V

1F236A

A/V

1F242A

15cd 15cd

15cd

15cd

15cd

WP

30cd

75cd

75cd

75cd

15cd

60cd

30cd

15cd

15cd

15cd

15cd

15cd

60cd

15cd

15cd 15cd 15cd

15cd

AASD

AASD

75cd

75cd

75cd

75cd

75cd

C O

R R

ID

O

R

1F

/1 FA111 /1 FA112

/1 FA115

/1 FA117

/1 FA115

/1 FA118

MM

MM

WF

VS

PROVIDED FOR

ELEVATOR CONTROL

ROOM SPRINKLERS

15cd

/1 FA111

/1 FA117

VESTIBULE

1F217B

PROVIDE DETECTION

BELOW FLOOR, IN

ROOM, AND ABOVE

CEILING

75cd

EC

ASDS

FA

75cd

ASDS

75cd

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:17 PM

FA114

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1ST FLOOR - SECTOR 4 FIRE ALARM PLAN

CC

S

C

S

C

S

C

CCC

S

C

C

C

C

S

C

C

C C

C

S

C

C

S

C

S

S

C

C

GG

F.6F.6

F.3F.3

FF

EE

D.7D.7

D.4D.4

DD

3.6

3.6

5.4

5.4

MP-1

1F244

STORAGE

1F235

BATTLE CAB

1F223

BREAKOUT

1F226

A/V SERVER

1F243

ELEC

1F222

A/V SERVER

1F221

BREAKOUT

1F246

BREAKOUT

1F245

BREAKROOM

1F237

PANTRY

1F238

ESS

1F234

SHADOW OPS FLOOR

1F217

FITNESS STORAGE

1F205

CORRIDOR

1F214

STAIR 6

ST6

STAIR 5

ST5

A/V

1F206

A/V

1F242A

15cd

15cd

15cd

30cd30cd

15cd

15cd

15cd

15cd

15cd

15cd 15cd

75cd

75cd

75cd

15cd

75cd

75cd

75cd

TRANSITION GROUP

1F229

FITNESS

1F204

/1 FA111 /1 FA112

/1 FA114

/1 FA112 /1 FA113

/1 FA116

/1 FA114

/1 FA117 /1 FA118

/1 FA116

/1 FA118 /1 FA119

15cd

VESTIBULE

1F217B

VESTIBULE

1F223A

CUST. SERVICE

1F230A

15cd

NSDC OPS FLOOR

1F236

15cd

VESTIBULE

1F244A

EC

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:20 PM

FA115

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'1/8" = 1'-0"1

1ST FLOOR - SECTOR 5 FIRE ALARM PLAN

S

C

S

C

C

S

C

S

F

F

C

P

P

C

S

CC

C

CC

S

C

C

C

C

C

C

C

L O C

ET

FACU

P

S

C

S GG

F.6F.6

F.3F.3

FF

EE

D.7D.7

D.4D.4

DD

6.7

6.7

7.5

7.5

8.4

8.4

8.8

8.8

PC-1

1F231

SHOWER

1F202

STORAGE

1F105

VESTIBULE

1F100

TRANSITION GROUP

1F229

FITNESS

1F204

CORRIDOR

1F106

ELEV 3

ELEV 3

ELEV 2

ELEV 2

SHOWER

1F208

ELEVATOR LOBBY

1F121

C O

R R

ID

O

R

1F

LOBBY

1F101

CONTROL CLST

1F228

ELECTRICAL RM

1F118

NIPR ROOM

1F102

MAIL RM

1F119

JAN

1F109

MENS

1F108

WOMENS

1F107

GUARD STATION

1F103

INTERVIEW RM

1F104

15cd

15cd

30cd

WP

15cd15cd

15cd

15cd15cd

30cd

15cd

15cd

15cd

15cd

15cd

15cd 60cd

60cd

60cd

15cd

60cd

C O

R R

ID

O

R

1F

SECURITY

1F230

/1 FA112

/1 FA115

/1 FA113

/1 FA115

/1 FA118 /1 FA119

VS

WF

MM

MM

15cd

/1 FA119

/1 FA113

EC

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:22 PM

FA116

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1/8" = 1'-0"1

1ST FLOOR - SECTOR 6 FIRE ALARM PLAN

KEYED NOTES :

1. THIS FACU SHALL SERVE THE NON-SECURE SPACE.

S

C

S

C

C

S

C

S

F

F

C C

P

P

C

S

CC

C

CC

S

C

C

C

C

C

C

C

C C

C

S

L O C

ET

FACU

P

S

C

S

FAPX

GG

F.6F.6

F.3F.3

FF

EE

D.7D.7

D.4D.4

DD

6.7

6.7

7.5

7.5

8.4

8.4

8.8

8.8

WOMEN

1F117

MEN

1F116

MECHANICAL

1F113

PC-1

1F231

LOCKER RM

1F201

LOCKER RM

1F207

SHOWER

1F202

STORAGE

1F105

VESTIBULE

1F100

TRANSITION GROUP

1F229

FITNESS

1F204

CORRIDOR

1F106

ELEV 3

ELEV 3

ELEV 2

ELEV 2

SHOWER

1F208

ELEVATOR LOBBY

1F121

C O

R R

ID

O

R

1F

LOBBY

1F101

CONTROL CLST

1F228

ELECTRICAL RM

1F118

NIPR ROOM

1F102

MAIL RM

1F119

JAN

1F109

MENS

1F108

WOMENS

1F107

GUARD STATION

1F103

INTERVIEW RM

1F104

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

30cd

15cd

15cd 15cd

30cd

60cd

60cd

60cd

60cd

15cd 15cd

15cd

15cd 15cd

C O

R R

ID

O

R

1F

VS

WF

MM

MM

PROVIDED FOR

ELEVATOR CONTROL

ROOM SPRINKLERS

/1 FA112

/1 FA115

/1 FA113 /1 FA113

SECURITY

1F230

/1 FA115 /1 FA116

/1 FA118

/1 FA116

EC

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

4 5 6A

7 8 9A

KEY PLAN

PLAN NORTH

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:25 PM

FA116A

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

B

ID

O P

T

IO

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1ST FLOOR - SECTOR 6 FIRE ALARM PLAN - BID OPTION

C

S

C

S

C

F

S

C

C

C

C

C S

C

C

C

C

C

S

C

S

C C

CC

S

S

ET

LOC

CC

S

C

S

K

K

FAPXFAPXFAPX

DD

C.5C.5

C.3C.3

CC

0.5

0.5

2.3

2.3

3.6

3.6

AA

BB

TEAM RM

1F182

J6 LAB

1F185

DIRECTOR

1F184

DEP DIR

1F183

J6 CONFERENCE

ROOM

1F186

MECHANICAL

1F210

IDF

1F211

MECHANICAL

1F180

ELEC

1F175

VEST

1F127

VTC ROOM

1F219

STAIR 3

ST3

J6

1F181

TEAM ROOM

1F179

A/V

1F217A

15cd

30cd

15cd

WP

115cd

115cd

115cd

115cd

30cd 30cd

15cd

15cd

15cd

15cd

15cd

CORRIDOR

1F126

MECHANICAL

1F171

C O

R R

ID

O

R

1F

AHU-104

RETURN

AHU-104

SUPPLY

AHU-103

RETURN

AHU-103

SUPPLY

75cd75cd

/1 FA114 /1 FA115

/1 FA118

15cd

/1 FA114

AHU-103

AHU-104

F A

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:27 PM

FA117

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1ST FLOOR - SECTOR 7 FIRE ALARM PLAN

C

S

C

S

CC

S

C

C

C C C C

C

C

C

C

C

DD

C.5C.5

C.3C.3

CC

3.6

3.6

5.4

5.4

AA

BB

MDF

1F197

OPERATIONS

SOFTWARE

DEVELOPMENT

1F188

DEVELOPMENT

CENTER

1F189

MODELING /

SIMULATION

1F190

TRAINING ROOM

1F195

JANITOR

1F191

CORRIDOR

1F126

CREW BRIEFING RM

1F220

15cd

75cd

75cd

15cd 30cd 30cd 75cd

115cd

115cd

115cd

115cd

30cd

75cd 75cd

/1 FA114

/1 FA117

/1 FA115

/1 FA115 /1 FA116

/1 FA119

CORRIDOR

1F126

TRAINING ROOM

1F195

F A

F A

SHADOW OPS FLOOR

1F217

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:30 PM

FA118

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1ST FLOOR - SECTOR 8 FIRE ALARM PLAN

C

C

S

C

S

C

C

S

C

S

C

C

S

C

S

CC

ET

LOC

F

C

S

DD

C.5C.5

C.3C.3

CC

6.7

6.7

7.5

7.5

8.4

8.4

8.8

8.8

AA

BB

MDF

1F197

IDF

1F192

LOCKER RM

1F201

LOCKER RM

1F207

SHOWER

1F202

VEST

1F198

SHOWER

1F208

MEN

1F209

WOMEN

1F200

STAIR 4

ST4

ALCOVE

1F128

ELEC

1F203

15cd

15cd

60cd

WP

30cd

30cd30cd

C O

R R

ID

O

R

1F

CORRIDOR

1F126

C O

R R

ID

O

R

1F

/1 FA115 /1 FA116

/1 FA118

15cd

F A

/1 FA116

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:32 PM

FA119

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1ST FLOOR - SECTOR 9 FIRE ALARM PLAN

C

C

S

C

S

C

C

S

C

S

C

C

S

C

S

CC

C

S

C

C

F

S

C

S

C C

F

F

ET

LOC

S

S S

F

LOC

F

C

S

DD

C.5C.5

C.3C.3

CC

6.7

6.7

7.5

7.5

8.4

8.4

8.8

8.8

AA

BB

AUDITORIUM

1F115

ELEC

1F114

CORRIDOR

1F112

MDF

1F197

IDF

1F192

LOCKER RM

1F201

LOCKER RM

1F207

SHOWER

1F202

VEST

1F198

SHOWER

1F208

MEN

1F209

WOMEN

1F200

JANITOR

1F191

STAIR 4

ST4

ALCOVE

1F128

ELEC

1F203

WP

30cd

15cd 15cd

15cd

60cd

15cd

30cd 30cd

CORRIDOR

1F126

C O

R R

ID

O

R

1F

C O

R R

ID

O

R

1F

15cd

15cd

135cd 135cd

135cd 135cd

135cd

JANITOR

1F115B

/1 FA115 /1 FA116

/1 FA118

F A

/1 FA116

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

4 5 6A

7 8 9A

KEY PLAN

PLAN NORTH

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:35 PM

FA119A

S

T F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

B

ID

O P

T

IO

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1ST FLOOR - SECTOR 9 FIRE ALARM PLAN - BID OPTION

LOC

L O C

LOC

LOC

K

JJ

II

HH

GG

FF

EE

DD

CC

0.5

0.5

2.3

2.3

3.6

3.6

5.4

5.4

6.7

6.7

7.5

7.5

8.4

8.4

AA

BB

OPEN TO BELOW

OPEN TO BELOW

H.6H.6

FAPX

FAPX

FAPX

F A

P X

F A

P X

F A

P X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:41 PM

FA120

N

D F

L O

O R

C

O M

P O

S

IT

E F

IR

E

A L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 3/64" = 1'-0"

16' 8' 0' 16' 48'32'

2ND FLOOR - COMPOSITE FIRE ALARM PLAN

L O C

LOC

LOC

K

JJ

II

HH

GG

FF

EE

DD

CC

0.5

0.5

2.3

2.3

3.6

3.6

5.4

5.4

6.7

6.7

7.5

7.5

8.4

8.4

AA

BB

DN

OPEN TO BELOW

OPEN TO BELOW

H.6H.6

FAPX

FAPX

FAPX

F A

P X

F A

P X

F A

P X

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

4 5 6A

7 8 9A

KEY PLAN

PLAN NORTH

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:49 PM

FA120A

N

D F

L O

O R

C

O M

P O

S

IT

E F

IR

E

A L A

R M

P L A

N

B

ID

O P

T

IO

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 3/64" = 1'-0"

16' 8' 0' 16' 48'32'

2ND FLOOR - COMPOSITE FIRE ALARM PLAN - BID OPTION

C

CC

F

C

C

C

C

C

C

S

S

S

C

S C

C

C

C

S

ET

LOC

K

K

KFAPX FAPX FAPX

JJ

II

HH

G.7G.7

G.5G.5

0.5

0.5

2.3

2.3

3.6

3.6

STAIR 1

ST1

J5 DIRECTOR

2F128

J5 SERVER RM

2F129

CA

2F126

IDF

2F208

MECHANICAL

2F209

J5 OPEN OFFICE

2F125

MECHANICAL

2F131

ELEC

2F140

J3 IPO OPEN OFFICE

2F141

BREAK AREA

2F130

JAN.

2F123

15cd

30cd30cd

15cd

15cd

15cd

30cd

30cd

30cd

30cd

15cd

15cd

15cd

J3 OPEN OFFICE

2F205

CORRIDOR

2F231

C O

R R

ID

O

R

2F

AHU-203

RETURN

AHU-203

SUPPLY

AHU-204

RETURN

AHU-204

SUPPLY

/1 FA124

/1 FA122

/1 FA125

F A

AHU-203

AHU-204

H.6H.6

/1 FA124

AHU-202

AHU-202

SUPPLY

AHU-202

RETURN

75cd

75cd

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:52 PM

FA121

N

D F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

2ND FLOOR - SECTOR 1 FIRE ALARM PLAN

C C

S

C

S

C

S

C C C C

CC

S

C

C C

CC

C

II

HH

G.7G.7

G.5G.5

GG

3.6

3.6

5.4

5.4

NSDC OPS FLOOR

1F236

J5 DEP DIR

2F127

J8 DEP DIR

2F120

J8 DIRECTOR

2F119

J8 OPEN OFFICE

2F118

WOMEN

2F121

MEN

2F122

CORRIDOR

2F231

TEAM RM

2F111

15cd

15cd 15cd 15cd 15cd

75cd75cd

30cd 30cd

30cd30cd

75cd

J2 OPEN OFFICE

2F221

/1 FA121

F A

F A

/1 FA125

/1 FA123

/1 FA126

H.6H.6

/1 FA124

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:54 PM

FA122

N

D F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

2ND FLOOR - SECTOR 2 FIRE ALARM PLAN

S

C

C

C

C

C

C

C

C

C

C

C

S

C

C C

S

C

C

S

C

S

C

S

C C

S

C

C C

S

C C

P

P

S

S

S S

ET

LOC

K

II

HH

G.7G.7

G.5G.5

GG

F.6F.6

6.7

6.7

7.5

7.5

8.4

8.4

STAIR 2

ST2

SERVICE ELEVATOR

ELEV 1

J2 OPEN OFFICE

2F221

OPEN OFFICE

2F106

ELECTRICAL

2F101

DIRECTOR

2F108

DEP DIR

2F107

TEAM RM

2F109

DEP DIR

2F104

MECHANICAL

2F102

DIRECTOR

2F103

TEAM RM

2F105

IDF

2F115

CONTROL CLST

2F112

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

75cd

75cd 75cd

75cd 75cd

30cd

30cd 75cd

OPEN OFFICE

2F106

CORRIDOR

2F231 C

O R

R

ID

O R

2F

C O

R R

ID

O

R

2F

J2 OPEN OFFICE

2F221

AHU-201

RETURN

AHU-201

SUPPLY

/1 FA122

/1 FA125 /1 FA126

F A

AHU-201

H.6H.6

MM

MM

WF

VS

PROVIDED FOR

ELEVATOR CONTROL

ROOM SPRINKLERS

/1 FA126

OPEN OFFICE

2F106

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:56 PM

FA123

N

D F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

2ND FLOOR - SECTOR 3 FIRE ALARM PLAN

C

S

C

S

C

C

S

C

S

C

C

C

C

C C

C

S C

S

C C

C

C

C

C C

C

C

C

C

S

C

C

P

F.6F.6

D.7D.7

D.4D.4

D

D

0.5

0.5

2.3

2.3

3.6

3.6

J35 TREX OPEN

OFFICE

2F144

J3 OPEN OFFICE

2F205

C O

R R

ID

O

R

2F

TEAM RM

2F211

J3 BSA OPEN OFFICE

2F142

A/V

2F210A

15cd

30cd

30cd

30cd

30cd

75cd 75cd

75cd 75cd

30cd

15cd

15cd

30cd 75cd

30cd

75cd

75cd

30cd

75cd

J3 OPEN OFFICE

2F205

C O

R R

ID

O

R

2F

J3 OPEN OFFICE

2F205

/1 FA122

/1 FA125

/1 FA121/1 FA121

/1 FA127

/1 FA125

/1 FA128/1 FA127

ELEV 4

ELEV 4

J3 CONFERENCE RM

2F210

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:03:58 PM

FA124

N

D F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

2ND FLOOR - SECTOR 4 FIRE ALARM PLAN

C

C C

C

C

C

C

S

CC

C

C

C

C

C

S

C

S

C

S

C

S

C

S

GG

F.6F.6

F.3F.3

FF

EE

D.7D.7

D.4D.4

DD

3.6

3.6

5.4

5.4

SHADOW OPS FLOOR

1F217

DIV CHIEF

2F219

EXECUTIVE

CONFERENCE RM

2F213

J2 OPEN OFFICE

2F217

A/V RM/ TECH RM

2F215

OVERLOOK

2F214

OVERLOOK

2F216

ALCOVE

2F212

TEAM RM

2F110

OVERLOOK

2F113

OVERLOOK

2F114

STORAGE RM

2F222 15cd

15cd 15cd

15cd 15cd

15cd

15cd

75cd

75cd30cd

30cd

30cd

30cd

75cd

J3 OPEN OFFICE

2F205

ELEVATOR LOBBY

2F235

NSDC OPS FLOOR

1F236

J2 OPEN OFFICE

2F221

J24 OPEN OFFICE

2F202

/1 FA122/1 FA121 /1 FA122 /1 FA123

/1 FA126

/1 FA128 /1 FA128

/1 FA126

/1 FA129/1 FA127

/1 FA124

/1 FA124

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:04:00 PM

FA125

N

D F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

2ND FLOOR - SECTOR 5 FIRE ALARM PLAN

S

C

S

C

C

S

C

S

C

C

P

C

C

C

C

C

C

S

C C

S

C

L O C

GG

F.6F.6

F.3F.3

FF

EE

D.7D.7

D.4D.4

DD

6.7

6.7

7.5

7.5

8.4

8.4

J2 CONFERENCE RM

2F218

TEAM RM

2F204

J24 OPEN OFFICE

2F202

TARG

2F220

C O

R R

ID

O

R

2F

ELEVATOR LOBBY

2F235

15cd

15cd

30cd

15cd

15cd

15cd

75cd

15cd

75cd

75cd 75cd

C O

R R

ID

O

R

2F

J2 OPEN OFFICE

2F221

C O

R R

ID

O

R

2F

/1 FA122

/1 FA125

/1 FA123

/1 FA125

/1 FA128 /1 FA129 /1 FA129

/1 FA123

OPEN OFFICE

2F106

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:04:02 PM

FA126

N

D F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

2ND FLOOR - SECTOR 6 FIRE ALARM PLAN

S

C

S

C

C

S

C

S

C

C

P

C

C

C

C

C

C

S

C C

S

C

L O C

GG

F.6F.6

F.3F.3

FF

EE

D.7D.7

D.4D.4

6.7

6.7

7.5

7.5

8.4

8.4

8.8

8.8

J2 CONFERENCE ROOM

2F218

TEAM ROOM

2F204

J2 OPEN OFFICE

2F221

J24 OPEN OFFICE

2F202

TARG

2F220

C O

R R

ID

O

R

2F

ELEVATOR LOBBY

2F235

OPEN OFFICE

2F106

15cd

15cd

75cd

15cd

15cd

15cd

15cd

75cd

75cd 75cd

30cd

/1 FA122

/1 FA125

/1 FA123 /1 FA123

C O

R R

ID

O

R

2F

/1 FA125

/1 FA128

/1 FA126 /1 FA126

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

A F

-1

-0

F

IL

E N

A M

E

4 5 6A

7 8 9A

KEY PLAN

PLAN NORTH

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:04:04 PM

FA126A

N

D F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

B

ID

O P

T

IO

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

2ND FLOOR - SECTOR 6 FIRE ALARM PLAN - BID OPTION

S

C

S

C

S

C

S

C

C

C C

C

C C

C

C

C

C

CC

C

C

C

C

C

C

C

C C C

C

C

C

C

C

S

SSC

S

S

CC

C

CC

C

C

S

C

S

ET LOC

K

K

FAPX

FAPX

FAPX

C

DD

C.5C.5

C.3C.3

CC

0.5

0.5

2.3

2.3

3.6

3.6

AA

BB

STAIR 3

ST3

IDF

2F207

MECHANICAL

2F206

CHIEF OF STAFF

2F159

COMMANDER

2F155

DEPUTY

COMMANDER

2F156

SR. INTEL OFFICER

2F157

DEPUTY CDR AIDE DE

CAMP

2F158

DV SUITE

2F166

RECEPTION

2F163

PROTOCOL OPEN

OFFICE

2F164

WORK RM

2F165

A/V TECH RM

2F161

J4 DIV CHIEF

2F170

CHIEF OF SECURITY

2F172

J1 DIRECTOR

2F169

TEAM RM

2F168

RECEPTION

2F151

TEAM RM

2F145

ELEC

2F149

JTFSD OPEN OFFICE

2F152

MECHANICAL

2F150

J006, J1, J4, SECURITY OPEN

OFFICE

2F167

A/V

2F147

TEAM RM

2F203

TRAINING

2F146

VTC

2F148

15cd

15cd

15cd 15cd

15cd

15cd 15cd

15cd

30cd

15cd

30cd

15cd15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd

15cd 30cd 30cd

30cd

30cd

30cd

15cd

30cd

75cd75cd

30cd

15cd

75cd 75cd

C O

R R

ID

O

R

2F

32 J3 OPEN OFFICE

2F205

CORRIDOR

2F233

AHU-206

RETURN

AHU-206

SUPPLY

AHU-205

SUPPLY

AHU-205

RETURN

/1 FA124 /1 FA125

/1 FA128

F A

/1 FA124

AHU-205

AHU-206

DEDICATED OFFICE

2F160

EXEC OFFICER

2F154

SR. ENLISTED

2F153

TOILET

2F155A

COMMANDERS

CONFERENCE RM

2F162

15cd

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:04:07 PM

FA127

N

D F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'1/8" = 1'-0"1

2ND FLOOR - SECTOR 7 FIRE ALARM PLAN

C

S

C

S

C

C

C C C

C

C

C

C

C

C

C

C

C

C

C

C

CC

C

C

C

C

C

C

C

S

C

S

C

DD

C.5C.5

C.3C.3

CC

3.6

3.6

5.4

5.4

AA

BB

SHADOW OPS FLOOR

1F217

J7 DEP DIR

2F185

SR. ATTY J006

2F171

J4 DIV CHIEF

2F170

TEAM RM

2F168

NSDC DIRECTOR

2F182

J3 DEP DIR

2F180

J2 DEP DIR

2F181

DIR OPS

2F179

STORAGE

2F176

A/V

2F175

NSDC CONFERENCE

RM

2F174

J7 DIRECTOR

2F186

WAITING

2F173

NSDC OPEN OFFICE

2F177

TEAM RM

2F178

J7 OPEN OFFICE

2F183

TEAM RM

2F184

BREAK AREA

2F234

JANITOR

2F190

CORRIDOR

2F233

CI

2F189

15cd

15cd

15cd 15cd 15cd

15cd

15cd

60cd

15cd

15cd

15cd

15cd

15cd

30cd

15cd

110cd

110cd

30cd30cd

15cd

15cd

15cd

30cd

60cd

60cd

J24 OPEN OFFICE

2F202

/1 FA125 /1 FA125 /1 FA126

/1 FA129

F A

F A

/1 FA127

/1 FA124

SR ENLISTED

2F191

J006, J1, J4, SECURITY OPEN

OFFICE

2F167

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:04:09 PM

FA128

N

D F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

2ND FLOOR - SECTOR 8 FIRE ALARM PLAN

S

CC

S

C

C

C C

S

ET

LOC

C

S

DD

C.5C.5

C.3C.3

CC

6.7

6.7

7.5

7.5

8.4

8.4

AA

BB

STAIR 4

ST4

IDF

2F188

WOMEN

2F200

MEN

2F201

ELEC

2F223

15cd

30cd

30cd

30cd 30cd

J7 OPEN OFFICE

2F183

C O

R R

ID

O

R

2F

C O

R R

ID

O

R

2F

CORRIDOR

2F233

/1 FA125

/1 FA128

/1 FA126

F A

15cd

/1 FA126

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

D

C

B

A

D A

T E

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

F

IL

E N

U M

B E

R

P

4 5 6

KEY PLAN

PLAN NORTH

W F

R

O M

A H

A D

IS

T

R

IC

T C

A P

IT

A

L A

V E

N U

E

O M

A H

A N

E B

R A

S K

A

-1

-2

CSOF PACKAGE - 90% CORRECTED DESIGN

E

F

G

8 9

A F

-1

-0

F

IL

E N

A M

E

C S

C

K A

G E

C O

N S

O L

ID

A T

E D

S P

A C

E O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

B L D

G N

O

3/9/2021 3:04:11 PM

FA129

N

D F

L O

O R

S

E C

T O

R

F

IR

E A

L A

R M

P L A

N

S C

H R

IE

V

E R

A F

B C

O L O

R A

D O

N S

A N

M A

N N

N S

A N

M A

N N

K C

L A

Y

T W

IL

L

IS

S H

-G

L E

N -3

-C

S O

F -F

.R

V T

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

2ND FLOOR - SECTOR 9 FIRE ALARM PLAN

S

CC

S

C

C

C C

S

F

ET

LOC

CC

S

S

DD

C.5C.5

C.3C.3

CC

6.7

6.7

7.5

7.5

8.4

8.4

8.8

8.8

AA

BB

AUDITORIUM

1F115

STAIR LANDING

2F133

IDF

2F188

WOMEN

2F200

MEN

2F201

JANITOR

2F190

ELEC

2F223

DN

30cd

30cd

15cd

30cd30cd

15cd

J7 OPEN OFFICE

2F183

STAIR 4

ST4

/1 FA125

/1 FA128

/1 FA126

F A

/1 FA126

15cd

15cd

OPEN TO BELOW

US Army Corps of Engineers…

This is the start of the file's text. The full file is on GovTribe.