W9128A-18-B-0002_Am-0007_Drawings_(3_of_6).pdf

PDF 20 MB Posted

Attached to
FY16 MCAF KNMD043004, Fighter Alert Facility, Joint Base Pearl Harbor-Hickam (JBPHH), Oahu, Hawaii
Solicitation number
W9128A-18-B-0002
Issued by

About this file

Am-0007 - Drawings (3 of 6)

View the file

Other files

File Type Posted
W9128A-18-B-0002_Abstract_of_Bids.pdf PDF
W9128A-18-B-0002_Am-0013.pdf PDF
W9128A-18-B-0002_Am-0013_Specifications.pdf PDF
W9128A-18-B-0002_Am-0013_Drawings.pdf PDF
W9128A-18-B-0002_Am-0012.pdf PDF
W9128A-18-B-0002_Am-0011_Drawings_(3_of_3).pdf PDF
W9128A-18-B-0002_Am-0011_Drawings_(2_of_3).pdf PDF
W9128A-18-B-0002_Am-0011_Drawings_(1_of_3).pdf PDF
W9128A-18-B-0002_Am-0011_Specifications.pdf PDF
W9128A-18-B-0002_Am-0011.pdf PDF
W9128A-18-B-0002_Am-0010_Specifications.pdf PDF
W9128A-18-B-0002_Am-0010.pdf PDF
W9128A-18-B-0002_Am-0010_Drawings_(1_of_3).pdf PDF
W9128A-18-B-0002_Am-0010_Drawings_(3_of_3).pdf PDF
W9128A-18-B-0002_Am-0010_Drawings_(2_of_3).pdf PDF
W9128A-18-B-0002_Am-0009.pdf PDF
W9128A-18-B-0002_Am-0008.pdf PDF
W9128A-18-B-0002_Am-0008_Specifications.pdf PDF
W9128A-18-B-0002_Am-0007_Drawings_(2_of_6).pdf PDF
W9128A-18-B-0002_Am-0007_Drawings_(5_of_6).pdf PDF
W9128A-18-B-0002_Am-0007_Drawings_(6_of_6).pdf PDF
W9128A-18-B-0002_Am-0007.pdf PDF
W9128A-18-B-0002_Am-0007_Drawings_(4_of_6).pdf PDF
W9128A-18-B-0002_Am-0007_Drawings_(1_of_6).pdf PDF
W9128A-18-B-0002_Am-0006.pdf PDF
W9128A-18-B-0002_Am-0005_Drawings_(2_of_3).pdf PDF
W9128A-18-B-0002_Am-0005_Drawings_(1_of_3).pdf PDF
W9128A-18-B-0002_Am-0005_Specifications.pdf PDF
W9128A-18-B-0002_Am-0005.pdf PDF
W9128A-18-B-0002_Am-0005_Drawings_(3_of_3).pdf PDF
W9128A-18-B-0002_Am-0004.pdf PDF
W9128A-18-B-0002_Am-0003_Drawings_(1_of_2).pdf PDF
W9128A-18-B-0002_Am-0003.pdf PDF
W9128A-18-B-0002_Am-0003_Drawings_(2_of_2).pdf PDF
W9128A-18-B-0002_Am-0003_Specifications.pdf PDF
W9128A-18-B-0002_Am-0002.pdf PDF
W9128A-18-B-0002_Am-0001.pdf PDF
W9128A-18-B-0002_Specifications.pdf PDF
W9128A-18-B-0002_Drawings_(2_of_2).pdf PDF
W9128A-18-B-0002_IFB.pdf PDF
W9128A-18-B-0002_Drawings_(1_of_2).pdf PDF
SECNAV_5512-1.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NORTH

EAST

SOUTH

WEST

KEY TO

EXTERIOR

ELEV

16'0 8'

SCALE: 3/16" = 1'-0"

4' 12'

S

S

211B

S

S

200E

S

S

S

S

S

S

S

S

S

228B

S

S

S

S

S

S

S

S

215E

S

205E

S

204E

S

MAINT QTRS #4

CQ 219

MAINT QTRS #3

CQ 218

MAINT QTRS #2

CQ 217

MAINT QTRS #1

CQ 216

EXERCISE ROOM

CQ 214

LOCKER ROOM

CQ 212

HALLWAY #2

QC 220

WOMEN'S

CQ 223

JANITOR

CQ 222

MEN'S

CQ 221

BATH #1

CQ 226

PILOT #1

CQ 225

PILOT #4

CQ 231

PILOT #3

CQ 229

PILOT #2

CQ 227

HALLWAY #1A

CQ 228

MAINT STOR

CQ 210

SUPER FLIGHT

CQ 209

LAV/ NAV

CQ 208

READY ROOM

CQ 200

MULTI-PURPOSE ROOM

CQ 201

KITCHEN

CQ 202

COMM

CQ 204

ELEC

CQ 205

WTT

CQ 206

SECURE ROOM

CQ 207

BATH #2

CQ 230

MECH

CQ 215

S

LAUNDRY

CQ 224

HALLWAY #1

CQ 211

S

S

228A

S

211A

S

232E

OPTION #1

PUMP ROOM

CQ232

S

233E

S

300E

STOR

EP 101

ELEC

EP 102

RESTROOM

EP 103

OFFICE

EP 100

S

S

100E

S

S

S

S

104E

SIGN SYMBOL , SEE SIGN SCHED

S

G#

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A W

A I I , U . S . A

S C

O

TT

R.J.

A D

A

HAR

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M A

IR

F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C o

S

M A

S C

O T

T R

J H

A R

A D

A

A

IA

S H

/8

/2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

K N

M D

SIGNATURE

LICENSE EXPIRATION DATE: 04/30/18

THIS WORK WAS PREPARED BY ME OR

UNDER MY SUPERVISION AND CONSTRUCTION

OF THIS PROJECT WILL BE UNDER MY

OBSERVATION.

A s i n d ic a t e d

/2

/1

A-605

C R

E W

Q U

A R

T E

R S

A N

D E

C P

S

IG

N

A G

E P

L A

N s b

-P

N

-B

N H

Q -A

-6 .d w g

LEGEND

KEY TO

INTERIOR

ELEVS.

A

B

C

D

A.1

B.1

C.1

D.1

OPTION DESCRIPTION

HEF PUMP ROOM AND WORK ASSOCIATED WITH THE

ROOM IS OPTION # 1

SCALE: 3/16" = 1'-0"A2

CREW QUARTER - SIGNAGE PLAN

SCALE: 3/16" = 1'-0"A1

ECP - SIGNAGE PLAN

1. ENTRY CONTROL

POINT

2. CREW QUARTERS

OPTION CALLOUT

A M

E N

D M

E N

T

/2

/1

A M

E N

D M

E N

T

/1

/1

410210

EAST

SOUTH

WEST

KEY TO

EXTERIOR

ELEV

NORTH

COMM

SA 414

ELEC RM

SA 415

MECH RM

SA 416

SA STAFF #1

SA 417

SA STAFF #2

SA 418

SA STAFF #3

SA 419

SA OIC

SA 420

OPEN OFFICE #1

SA 400

OPS VAULT #2

SA 401

MX VAULT

SA 403

OPS VAULT #1

SA 402

OPEN OFFICE #2

SA 404

HALLWAY #1

SA 405

MEN'S

SA 408

AFE

SA 406

EQUIPMENT STORAGE

SA 407

WOMEN'S

SA 410

SHOWER

SA 409

HALLWAY #2

SA 411

STOR

SA 413

JAN CLOSET

SA 412

S 400E

S

S

S 407E

S 414E

S 415E

S 416E

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S 421E

SIGN SYMBOL , SEE SIGN SCHED

S G#

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A W A I I , U . S . A

SC

OTT R.J.

ADA

HAR

SHEET

M A

R K

D E

S C

R

IP

TI

O

N A

P P

R

D A

TE

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

TI

O

N A

P P

R

D A

TE

JO

IN

T

BA

SE

P

EA

R

L H

AR

BO

R

H

IC

KA

M

, H

AW

AI

I

IN

K

AR

C

H , L

LC

D R

A W

N B

Y

S U

B M

IT

TE

D B

Y

P

LO

T S

C A

LE

S

IZ

E

A N

S I D

C H

E C

K E

D B

Y

IS

S

U E

D A

TE

FI

LE

N A

M E

D A

TE

S O

LI

C

IT

A

TI

O

N N

O

W

A

-0 9-

D -0

C O

N

TR

A C

T N

O

FI

LE

N U

M B

E R

H

IC

K A

M A

IR

F

O R

C E

B A

S E

, O A

H U

, H A

W A

II

FY

K

N M

D

F-

F

IG

H

TE

R A

LE

R

T

FA

C

IL

IT

Y

C oS

M A

S C

O

TT

R J

H A

R A

D A

, A

IA

S H

1/ 8/

IW

IL

EI

R

O

AD

, S U

IT

E

H O

N O

LU

LU

, H I 9

P:

-5

-1

K N

M D

SIGNATURE

LICENSE EXPIRATION DATE: 04/30/18

THIS WORK WAS PREPARED BY ME OR

UNDER MY SUPERVISION AND CONSTRUCTION

OF THIS PROJECT WILL BE UNDER MY

OBSERVATION.

A s in di ca te d

/2 0 /

A-606

SE

N

TR

Y

AL

O

H A

- S

IG

N

AG

E

PL

AN

sb

-P

N

3 1 1-

BN

H

Q

- A

-6

.d w g

LEGEND

KEY TO

INTERIOR

ELEVS.

A

B

C

D

A.1

B.1

C.1

D.1

4. SENTRY ALOHA

SCALE: 3/16" = 1'-0"A1 SENTRY ALOHA - SIGNAGE PLAN

AM

EN

D M

EN

T

6/

/1

410211

WOMEN

ELECTRICAL5

/8

/8

/8

/8

TYPE 1 TYPE 2

TYPE 4

RAISED CHARACTERS

HELVETICA TYPEFACE

ROOM NAME w/ GRADE

2 BRAILLE COPY,

JUSTIFY CENTER,

COLOR: TBD

RAISED

INTERNATIONAL

SYMBOLS, COLOR:

TBD

ADA TACTILE 1/8"

THK MATTE

ACRYLIC SIGN,

COLOR: TBD

RAISED CHARACTERS

HELVETICA TYPEFACE

ROOM NAME w/ GRADE 2

BRAILLE COPY, JUSTIFY

CENTER, COLOR: TBD

ADA TACTILE

ALUMINUM SIGN,

COLOR: TBD

/2

6"

1/2" 1/2"

TYPE 3

RAISED MELAMINE

PLANE GRAPHIC

1/8" THK MATTE ACRYLIC SIGN

PERMANENT RAISED

TEXT HELVETICA

TYPEFACE & BRAILLE

EQ EQ

TYPE 5

A F

F

NUMBERS 3M

REFLECTIVE WHITE,

VERIFY BUILDING

NUMBER

ALUMINUM SIGN -

COLOR 3M 180-29

RUSSET BROWN

/2

5"

/4

MEN 5

/8

/8

/2

5"

/4

UNISEX 5

/8

/8

TYPE 6

/2

5"

/4

RAISED

INTERNATIONAL

SYMBOLS, COLOR:

TBD

ADA TACTILE 1/8"

THK MATTE

ACRYLIC SIGN,

COLOR: TBD

RAISED CHARACTERS

HELVETICA TYPEFACE ROOM

NAME w/ GRADE 2 BRAILLE

COPY, JUSTIFY CENTER,

COLOR: TBD

CHANGEABLE

MESSAGE SLOT

/4

TYPE 7

NO

1/8" ACRYLIC

SIGN, COLOR:

TBD

EXIT

5"

HELVETICA

TYPEFACE,

COLOR : TBD

/4

3/8"5

9"

ELEVATION

ELECTRICAL

M

IN

H E

IG

H

T A

F F

T O

B O

T T

O M

O F

L O

W E

S T

T A

C T

IL

E

C H

A R

A C

T E

R

M

IN

H E

IG

H

T A

F F

T O

B O

T T

O M

O F

L O

W E

S T

T A

C T

IL

E

C H

A R

A C

T E

R

9"

ELECTRICAL

M

IN

H E

IG

H

T A

F F

T O

B O

T T

O M

O F

L O

W E

S T

T A

C T

IL

E

C H

A R

A C

T E

R

M

IN

H E

IG

H

T A

F F

T O

B O

T T

O M

O F

L O

W E

S T

T A

C T

IL

E

C H

A R

A C

T E

R

SINGLE DOOR DOUBLE DOOR

CL CL

18"

CENTERED ON

TACTILE CHARACTERS

SIGN PLAQUE:

ATTACH TO BACK PLATE

PER MANUFACTURE'S

RECOMMENDATIONS

BACK PLATE:

MATERIAL AND

METHOD OF

ATTACHMENT PER

MANUFACTURER'S

RECOMMENDATIONS

FACE OF FIN WALL

DOOR SWING

CLEAR SPACE

PLAN

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A W

A I I , U . S . A

S C

O

TT

R.J.

A D

A

HAR

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M A

IR

F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C o

S

M A

S C

O T

T R

J H

A R

A D

A

A

IA

S H

/8

/2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

K N

M D

SIGNATURE

LICENSE EXPIRATION DATE: 04/30/18

THIS WORK WAS PREPARED BY ME OR

UNDER MY SUPERVISION AND CONSTRUCTION

OF THIS PROJECT WILL BE UNDER MY

OBSERVATION.

A s i n d ic a t e d

/2

/1

A-607

S

IG

N A

G E

S C

H E

D U

L E

A N

D D

E T

A

IL

S s b

-P

N

-B

N H

Q -A

-6 .d w g

SCALE: 6" = 1'-0"B3

SIGNAGE DETAILS

INSTALLATION AND LOCATIONS OF ALL SIGNAGE SHALL

COMPLY WITH THE PROVISIONS OF THE ADA STANDARDS

FOR ACCESSIBLE DESIGN SECTION 703.

CONTRACTOR SHALL VERIFY SIZE OF PROPOSED SIGN

WITH MOUNTING LOCATION SHOWN AND NOTIFY ENGINEER

PRIOR TO SIGN FABRICATION OF ANY SIGNS THAT EXCEED

THE SPACE AVAILABLE.

SEE PLANS FOR LOCATIONS OF SIGNAGE.

SEE ADA STANDARDS FOR ACCESSIBLE DESIGN SECTION

703.4 FOR INSTALLATION HEIGHT AND LOCATION.

SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

1.

2.

3.

4.

5.

SCALE: 1" = 1'-0"A3

SIGN MOUNTING DETAILS

SIGNAGE SCHEDULE

KEYNOTE SIGN LOCATION SIGN TYPE MOUNTING LOCATION SIGN TEXT REMARKS

S100

S100E

S101

S102

S103

E

C P

C

R E

W Q

U A

R T

E R

S

S200E

S200

S204E

S205E

S206

S207

S208

S209

S210

S211A

S211B

S212

S215E

S216

S217

S218

S219

S220

S221

S222

S223

S224

S225

S227A

S228A

S227

S229

S231

S

E N

T R

Y A

L O

H A

S232E

S400

S400E

S401

S402

S403

S404

S406

S407E

S408

S409

S410

S411

S412

S413

S414E

S415E

S416E

S417

S418

LEFT SIDE OF BLDG

LEFT SIDE OF DR4

EXIT

"VERIFY"EXTERIOR

READY ROOM

RIGHT SIDE OF DR

LEFT SIDE OF

SERVICE WDW

RIGHT SIDE OF DR

EXTERIOR

EXTERIOR

EXTERIOR

EXTERIOR

RIGHT SIDE OF DR

RIGHT SIDE OF DR

RIGHT SIDE OF DR

COMM

ELECTRIC ROOM

WTT 3 RIGHT SIDE OF DR WEAPONS TATICAL

TRAINER

SECURE ROOM 3 LEFT SIDE OF DR SECURE ROOM

LAV/NAV 3 RIGHT SIDE OF DR "VERIFY"

SUPER FLIGHT 3 RIGHT SIDE OF DR "VERIFY"

MAINT STOR 3 LEFT SIDE OF DR STORAGE

LOCKER ROOM 3 RIGHT SIDE OF OPENING LOCKER ROOM

4 MECHANICAL ROOM

MAINT QTRS #1 LEFT SIDE OF DR3 "VERIFY"

MAINT QTRS #2 RIGHT SIDE OF DR3 "VERIFY"

MAINT QTRS #3 RIGHT SIDE OF DR3 "VERIFY"

MAINT QTRS #4 RIGHT SIDE OF DR3 "VERIFY"

LEFT SIDE OF DR4 EXITHALLWAY #2

LEFT SIDE OF DR1 MENMEN'S

LEFT SIDE OF DR4 JANITOR ROOMJANITOR

RIGHT SIDE OF DR2 WOMENWOMEN'S

RIGHT SIDE OF DR4 LAUNDRY ROOMLAUNDRY

LEFT SIDE OF DR4 PILOT #1PILOT #1

LEFT SIDE OF DR3 EXITHALLWAY #1

RIGHT SIDE OF DR3 "VERIFY"PILOT #2

LEFT SIDE OF DR4 EXITHALLWAY #1A

RIGHT SIDE OF DR4 "VERIFY"PUMP ROOM

LEFT SIDE OF DR4 EXITOPEN OFFICE #1

OPS VAULT #2 3 LEFT SIDE OF DR "VERIFY"

OPS VAULT #1 3 RIGHT SIDE OF DR "VERIFY"

MX VAULT 3 LEFT SIDE OF DR "VERIFY"

LEFT SIDE OF DR4 EXITHALLWAY #1

RIGHT SIDE OF DR3 "VERIFY"AFE

RIGHT SIDE OF DR4 STORAGE

EQUIPMENT

STORAGE

RIGHT SIDE OF DR1 MENMEN'S

LEFT SIDE OF DR4 SHOWERSHOWER

LEFT SIDE OF DR2 WOMENWOMEN'S

ON DOOR7 NO EXITHALLWAY #2

RIGHT SIDE OF DR4 JANITOR CLOSETJAN CLOSET

RIGHT SIDE OF DR4 STORAGESTOR

LEFT SIDE OF DR4 COMMCOMM

RIGHT SIDE OF DR4 ELECTRICAL ROOMELEC RM

RIGHT SIDE OF DR4 MECHANICAL ROOMMECH RM

LEFT SIDE OF DR3 "VERFIY"SA STAFF #1

RIGHT SIDE OF DR3 "VERFIY"SA STAFF #2

LEFT SIDE OF DR3 "VERFIY"SA STAFF #3

LEFT SIDE OF DR

RIGHT SIDE OF DR

OFFICE

STOR

ELEC

RESTROOM

6 UNISEX

ELECTRICAL ROOM

STORAGE

VERIFY NAME W/ USER

EXIT

LEFT SIDE OF DR3 "VERIFY"PILOT #3

PILOT #4 RIGHT SIDE OF DR3 "VERIFY"

OPTION # 1

"VERIFY"

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

VERIFY NAME W/ USER

RIGHT SIDE OF DR3 "VERFIY"SA OIC VERIFY NAME W/ USER

KEYNOTE SIGN LOCATION SIGN TYPE MOUNTING LOCATION SIGN TEXT REMARKS

SIGNAGE SCHEDULE con't

S420

HALLWAY #1 3 LEFT SIDE OF DR PILOT QUARTERS

HALLWAY #1 3 RIGHT SIDE OF DR EXIT

A M

E N

D M

E N

T

/2

/1

S419

A M

E N

D M

E N

T

/3

/1

RIGHT SIDE OF BLDG5 "VERIFY"EXTERIOR VERIFY NAME W/ USER

A M

E N

D M

E N

T

/0

/1

410212

Aircraft Corrosion

3'

0"

4' - 6" 2 3/4" 2 3/4"

3/

8" 2"

TX

T

3/

4"

4"

TX

T

4"

3/

4"

4"TX

T 3"

TX

T

3/

4"

GUIDELINES

ONLY, NOT TO

BE SHOWN, TYP

2 X 2 METAL

POST

FONT: HELVETICA

NEUE 65 MEDIUM,

COLOR TBD

1/4" THK STRIPE

6'

0"

FONT:

HELVETICA

NEUE 85 HEAVY,

COLOR TBD

Bldg 3408

Control Facility 154th Maint Group

TYPE 8

ALUMINUM SIGN,

COLOR TBD

2 X 2 METAL POST

FONT: HELVETICA

NEUE 55 ROMAN,

COLOR TBD

1' - 0" DIA

CONCRETE

FOOTING, SLOPE

TO DRAIN, TYP

1' - 0" DIA

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A W A I I , U . S . A

SC

OTT R.J.

ADA

HAR

SHEET

M A

R K

D E

S C

R

IP

TI

O

N A

P P

R

D A

TE

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

TI

O

N A

P P

R

D A

TE

JO

IN

T

BA

SE

P

EA

R

L H

AR

BO

R

H

IC

KA

M

, H

AW

AI

I

IN

K

AR

C

H , L

LC

D R

A W

N B

Y

S U

B M

IT

TE

D B

Y

P

LO

T S

C A

LE

S

IZ

E

A N

S I D

C H

E C

K E

D B

Y

IS

S

U E

D A

TE

FI

LE

N A

M E

D A

TE

S O

LI

C

IT

A

TI

O

N N

O

W

A

-0 9-

D -0

C O

N

TR

A C

T N

O

FI

LE

N U

M B

E R

H

IC

K A

M A

IR

F

O R

C E

B A

S E

, O A

H U

, H A

W A

II

FY

K

N M

D

F-

F

IG

H

TE

R A

LE

R

T

FA

C

IL

IT

Y

C oS

M A

S C

O

TT

R J

H A

R A

D A

, A

IA

S H

1/ 8/

IW

IL

EI

R

O

AD

, S U

IT

E

H O

N O

LU

LU

, H I 9

P:

-5

-1

K N

M D

SIGNATURE

LICENSE EXPIRATION DATE: 04/30/18

THIS WORK WAS PREPARED BY ME OR

UNDER MY SUPERVISION AND CONSTRUCTION

OF THIS PROJECT WILL BE UNDER MY

OBSERVATION.

/2

'-0

/1 5 /

A-607a

SI

G

N

AG

E

SC

H

ED

U

LE

A N

D D

ET

AI

LS

sb

-P

N

3 1 1-

BN

H

Q

- A

-6 a.

dw g

SIGNAGE SCHEDULE (EXTERIOR STAND ALONE )

KEYNOTE SIGN LOCATION SIGN TYPE MOUNTING LOCATION SIGN TEXT REMARKS

S104E1. ECP

2. CREW QUARTERS

3. ALERT SHELTER

EXTERIOR

VERIFY NAME W/ USER"VERIFY"

VERIFY NAME W/ USER

VERIFY NAME W/ USER

SCALE:NTS3B SIGN DETAIL

ON POSTS8 VERIFY NAME W/ USER"VERIFY"

S233E EXTERIOR ON POSTS8

VERIFY NAME W/ USER"VERIFY"S300E EXTERIOR ON POSTS8

INSTALLATION AND LOCATIONS OF ALL SIGNAGE SHALL

COMPLY WITH THE PROVISIONS OF THE ADA STANDARDS

FOR ACCESSIBLE DESIGN SECTION 703.

CONTRACTOR SHALL VERIFY SIZE OF PROPOSED SIGN

WITH MOUNTING LOCATION SHOWN AND NOTIFY ENGINEER

PRIOR TO SIGN FABRICATION OF ANY SIGNS THAT EXCEED

THE SPACE AVAILABLE.

SEE PLANS FOR LOCATIONS OF SIGNAGE.

SEE ADA STANDARDS FOR ACCESSIBLE DESIGN SECTION

703.4 FOR INSTALLATION HEIGHT AND LOCATION.

SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

1.

2.

3.

4.

5.

SIGNAGE NOTES:

4. SENTRY ALOHA VERIFY NAME W/ USER"VERIFY"S421E EXTERIOR ON POSTS8

AM

EN

D M

EN

T

6/

/1

PT

PT

CONTRACTOR TO COORDINATE WITH GOVERNMENT TO

DETERMINE FINAL LOCATIONS OF EXTERIOR STAND ALONE

SIGNS.

6.

410212a

410213

EAST

SOUTH

WEST

KEY TO

EXTERIOR

ELEV

NORTH

SCALE: 1/8"=1'-0"

4' 8' 12' 16' 20' 24'0

B

A

MAINT QTRS #4

CQ 219

MAINT QTRS #3

CQ 218

MAINT QTRS #2

CQ 217

MAINT QTRS #1

CQ 216

MECH

CQ 215

EXERCISE ROOM

CQ 214

LOCKER ROOM

CQ 212

WOMEN'S

CQ 223

JANITOR

CQ 222

MEN'S

CQ 221

BATH #1

CQ 226

PILOT #2

CQ 227

PILOT #1

CQ 225

PILOT #4

CQ 231

BATH #2

CQ 230

PILOT #3

CQ 229

HALLWAY #1A

CQ 228

HALLWAY #2

QC 220

MAINT STOR

CQ 210

SUPER FLIGHT

CQ 209

LAV/ NAV

CQ 208

READY ROOM

CQ 200MULTI-PURPOSE ROOM

CQ 201

KITCHEN

CQ 202

COMM

CQ 204

ELEC

CQ 205

WTT

CQ 206

SECURE ROOM

CQ 207

LAUNDRY

CQ 224

T Y

P

EXISTING CONC WALKWAY

(NIC)

EXISTING

TAXIWAY

(NIC)

MECH CONC PAD,

SEE CIVIL DWGS

CONCRETE

WALKWAY, SEE

CIVIL DWGS

PUMP ROOM

CQ 232

OPTION #1

OPTION #2

OPTION #2

A B

STOR

EP 101

ELEC

EP 102

RESTROOM

EP 103

OFFICE

EP 100

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A W

A I I , U . S . A

S C

O

TT

R.J.

A D

A

HAR

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M A

IR

F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C o

S

M A

S C

O T

T R

J H

A R

A D

A

A

IA

S H

/8

/2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

K N

M D

SIGNATURE

LICENSE EXPIRATION DATE: 04/30/18

THIS WORK WAS PREPARED BY ME OR

UNDER MY SUPERVISION AND CONSTRUCTION

OF THIS PROJECT WILL BE UNDER MY

OBSERVATION.

A s i n d ic a t e d

/0

/1

A-801

C R

E W

Q U

A R

T E

R S

A N

D E

C P

F

IN

IS

H F

L O

O R

P L A

N s b

-P

N

-B

N H

Q -A

-8 .d w g

LEGEND

SCALE: 1/8" = 1'-0"A2

CREW QUARTER - FINISH FLOOR PLAN

SCALE: 1/8" = 1'-0"A1

ECP - FINISH FLOOR PLAN

CONCRETE

CARPET

VINYL TILE

RUBBER TILE

PORCELAIN TILE, FOR FLOOR

SLOPES TO DRAINS SEE

PARTIAL FLOOR PLANS

OPTION CALLOUT

KEY TO

INTERIOR

ELEVS.

A

B

C

D

A.1

B.1

C.1

D.1

BID OPTION DESCRIPTION

HEF PUMP ROOM AND WORK ASSOCIATED WITH THE

ROOM IS A BID OPTION

CS

CPT

VCT

RT

PCT

EXTERIOR CONCRETE WALKWAY

SAWCUT LINE

1. ENTRY CONTROL

POINT

2. CREW QUARTERS

FINISH SYMBOL, SEE SHEET A-602 FOR

ADDITIONAL INFORMATION

PORCELAIN TILE, FOR FLOOR

SLOPES TO DRAINS SEE

PARTIAL FLOOR PLANS

PCT

RIGID GRID ACCESS FLOORING RAF

A M

E N

D M

E N

T

/2

/1

A M

E N

D M

E N

T

/3

/1

A M

E N

D M

E N

T

/0

/1

410214

GENERAL FIRE PROTECTION NOTES:

1. PRIOR TO COMMENCEMENT OF ANY FIRE PROTECTION WORK, CONTRACTOR SHALL

VERIFY THE EXISTING CONDITIONS AGAINST THE CONTRACT DOCUMENTS.

2. ALL PENETRATIONS THROUGH FIRE RATED WALL AND/OR FLOORS SHALL BE FIRE

STOPPED. SEE SHEETS F-121, F-131, & F-141 FOR FIRE RATED WALL LOCATIONS.

3. CONTRACTOR SHALL MARK AND IDENTIFY ALL FIRE WALLS, FIRE BARRIERS, FIRE

PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS AT 10'-0" HORIZONTAL

INTERVALS.

4. CONTRACTOR SHALL NOT CORE THROUGH BEAMS WITHOUT APPROVAL BY THE

CONTRACTING OFFICER.

5. CORING SHALL BE PERFORMED DRY UNLESS THE CONTRACTOR CAN PERFORM

WET CORING WITHOUT ANY DAMAGE TO SURROUNDING AREAS.

FIRE ALARM SYSTEM NOTES:

1. THE FIRE ALARM SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH

NFPA 72-2016 AND SPECIFICATION SECTION 28 31 76.

2. ALL DEVICES AND EQUIPMENT SHALL BE U.L. LISTED OR FM APPROVED.

3. DEVICE LOCATIONS AND CONDUIT ROUTING ARE CONCEPTUAL. DEVICES ARE SHOWN IN

SUGGESTED LOCATIONS. FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE

WITH APPLICABLE CODES, MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT

LISTINGS. COORDINATE LOCATIONS WITH LIGHTING SYSTEM.

4. ALL FIRE ALARM CONDUIT SHALL BE 3/4" MINIMUM. ALL CONDUIT IN FINISHED AREAS

SHALL BE CONCEALED. CONDUIT SYSTEM SHALL BE SEPARATE FROM SUPPRESSION

SYSTEM CONDUIT.

5. SYNCHRONIZE ALL VISUAL NOTIFICATION APPLIANCES. SYNCHRONIZE ALL AUDIBLE

NOTIFICATION APPLIANCES.

6. THE FIRE ALARM SIGNAL SHALL BE A TEMPORAL THREE PATTERN TONE. THE CARBON

MONOXIDE ALARM IF PROVIDED SHALL BE A TEMPORAL 4 PATTERN TONE.

7. VISUAL NOTIFICATION APPLIANCES SHALL BE 110 CANDELA UNLESS MARKED

OTHERWISE.

8. SIGNALING LINE CIRCUITS, INITIATING DEVICE CIRCUITS AND NOTIFICATION APPLIANCE

CIRCUITS SHALL BE CLASS B FOR SENTRY ALOHA. SIGNALING LINE CIRCUITS, INITIATING

DEVICE CIRCUITS AND NOTIFICATION APPLIANCE CIRCUITS FOR THE FOAM

SUPPRESSION SYSTEM, ALERT HANGAR AND CREW QUARTERS SHALL BE CLASS A.

9. SMOKE DETECTORS SHALL BE LOCATED A MINIMUM OF 3 FT. FROM SUPPLY AIR

DIFFUSERS.

10.PROVIDE SIGNAGE AT THE FIRE ALARM CONTROL PANEL IDENTIFYING THE POWER

PANEL AND CIRCUIT.

11.TRANSCEIVER SHALL BE A MONACO TRANSCEIVER, KING FISHER TRANSMITTER AS

APPROVED BY THE HIANG.

12.HANGER BAYS ARE CLASS I, DIV. 2 HAZARDOUS LOCATIONS TO 18 INCHES ABOVE THE

FLOOR. ALL DEVICES AND CONDUIT, WIRING IN THIS AREA SHALL BE SUITABLE FOR

CLASS I, DIV. 2 LOCATION.

13.THE BUILDING FIRE ALARM PANEL AND FOAM FIRE SUPPRESSION PANEL SHALL BE

SEPARATE.

14.ALL JUNCTION, TERMINAL AND PULLING BOXES AND COVERS SHALL BE PAINTED THE

COLOR RED AND SHALL BE IDENTIFIED WITH ENGRAVED LABELS BY ZONE AND CIRCUIT

THAT IT CONTAINS.

15.THE FIRE ALARM SYSTEM CONTRACTOR IS TO PROVIDE A COMPLETE ENGINEERED

SYSTEM, COMPLETE WITH CALCULATIONS AND FINAL DESIGN DRAWINGS SIGNED AND

SEALED BY AN INDIVIDUAL THAT HAS OBTAINED NATIONAL INSTITUTE FOR

CERTIFICATION IN ENGINEERING TECHNOLOGIES (NICET LEVEL III FIRE ALARM SYSTEMS)

CERTIFICATION IN ACCORDANCE WITH THE NFPA 72. THE DRAWINGS SHALL HAVE THE

QCFPE REVIEW STAMP PRIOR TO SUBMITTING TO THE GOVERNMENT FPE.

LOW LEVEL HIGH EXPANSION FOAM NOTES (CONTINUED)

7. FOAM CONCENTRATE PIPING SHALL BE WELDED OR FLANGED 304 STAINLESS STEEL.

8. THE MANUFACTURER'S REPRESENTATIVE SHALL BE PRESENT AT THE PRELIMINARY

AND THE FINAL TESTING OF THE SYSTEMS.

9. FOAM PIPING SIZING, GENERATOR LOCATIONS, AND TANK SIZE ARE TO BE TAKEN AS

MINIMUM REQUIREMENTS. CONTRACTOR MUST PROVIDE FULL FOAM SYSTEM

DESIGN BASED ON EQUIPMENT TO BE PROVIDED. PIPE SIZES SHALL MAINTAIN FLOW

VELOCITIES LESS THAN 20 FT/SEC.

10.CONDUIT SYSTEM SHALL BE SEPARATE FROM THE FIRE ALARM SYSTEM. ALL

CONDUIT WITHIN THE HANGAR BAY SHALL BE GRC AND WATER TIGHT FITTINGS.

11.ALL JUNCTION, TERMINAL AND PULLING BOXES AND COVERS SHALL BE PAINTED THE

COLOR RED AND SHALL BE IDENTIFIED WITH ENGRAVED LABELS BY ZONE AND

CIRCUIT THAT IT CONTAINS.

12.THE FIRE SUPPRESSION SYSTEM CONTRACTOR IS TO PROVIDE A COMPLETE

ENGINEERED SYSTEM, COMPLETE WITH CALCULATIONS AND FINAL DESIGN

DRAWINGS SIGNED AND SEALED BY AN INDIVIDUAL THAT HAS OBTAINED NATIONAL

INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES (LEVEL IV SPECIAL

HAZARD SYSTEMS) CERTIFICATION IN ACCORDANCE WITH THE APPLICABLE NFPA 11

AND 13. THE DRAWINGS SHALL HAVE THE QCFPE REVIEW STAMP PRIOR TO

SUBMITTING TO THE GOVERNMENT FPE.

LOW LEVEL HIGH EXPANSION FOAM NOTES:

1. LOW LEVEL HIGH-EXPANSION FOAM SYSTEM SHALL BE DESIGNED IN ACCORDANCE

WITH NFPA 11-2016, SPECIFICATION SECTION 21 13 20.00 20, AIR NATIONAL GUARD

DESIGN POLICY ANG ETL 15-01-03, UFC 4-211-01 "AIRCRAFT MAINTENANCE

HANGARS", AND AS INDICATED.

2. FOAM GENERATORS SHALL BE LOCATED SO THAT FOAM DISCHARGE CLOSE TO,

BUT NOT DIRECTLY ON AIRCRAFT FUSELAGE AND WINGS. GENERATORS SHALL BE

DESIGNED AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. THE

DESIGN IS BASED ON THE USE OF ANSUL JET-X-15A (UL) FOAM GENERATORS.

CONTRACTOR IS RESPONSIBLE TO ENSURE ALL DESIGN REQUIREMENTS ARE MET

IF OTHER GENERATOR IS USED, INCLUDING BUT NOT LIMITED TO; WATER TANK

CAPACITY, FIRE PUMP SIZE, PIPE AND EQUIPMENT SIZES, CONCENTRATE CAPACITY,

AND GENERATOR LAYOUT.

3. FOAM SYSTEM SHALL COVER 90% OF THE AIRCRAFT SILHOUETTE AREAPROJECTED

ON THE FLOOR IN ONE MINUTE OR LESS.

4. MINIMUM FLOW RATE OF DISCHARGE SHALL BE IN ACCORDANCE WITH NFPA 11, BUT

SHALL NOT BE LESS THAN 2.6 CF MIN/SF.

5. 2% HIGH EXPANSION FOAM SHALL BE USED AND SHALL BE LISTED/APPROVED FOR

USE WITH FOAM GENERATORS BEING INSTALLED.

6. PROVIDE A CONNECTED FOAM CONCENTRATE SUPPLY, SIZED FOR A SINGLE 15

MINUTE APPLICATION OF FOAM OR 4 TIMES THE SUBMERGENCE VOLUME,

WHICHEVER IS GREATER. CONNECTED FOAM RESERVE IS NOT REQUIRED.

FIRE SPRINKLER SYSTEM NOTES: (CONTINUED)

THE EXISTING WATER SUPPLY IS INADEQUATE TO SUPPLY THE SPRINKLER

SYSTEM AND HI-EX FOAM SYSTEM. A NEW FIRE PUMP BUILDING AND FIRE PUMP

WILL BE PROVIDED.

CALCULATIONS SHALL UTILIZE THE BASE WATER SUPPLY AND FIRE PUMP.

CALCULATION SHALL BE PROVIDED TO MODEL BOTH THE HI-EX FOAM

GENERATORS AND SPRINKLERS IN THE SAME CALCULATION.

THE CREW QUARTERS AND SENTRY ALOHA SHALL BE DESIGNED USING THE

BASE WATER SUPPLY. CALCULATIONS SHALL PROVIDE A 10% SAFETY

CUSHION.

6. SPRINKLER PIPING SHALL COMPLY WITH NFPA 13, EXCEPT THAT COPPER AND

PLASTIC PIPE SHALL NOT BE PERMITTED. ALL PIPING IN FINISHED AREAS SHALL BE

CONCEALED.

7. THE PIPE ROUTING AND SPRINKLER LOCATIONS ARE CONCEPTUAL. THE

CONTRACTOR SHALL INSTALL THE SYSTEM IN ACCORDANCE WITH THE APPLICABLE

CODES, MANUFACTURER'S RECOMMENDATIONS AND EQUIPMENT LISTINGS.

8. ALL FIRE SPRINKLER AND FOAM SYSTEM PIPING SHALL BE PROVIDED WITH

EARTHQUAKE PROTECTION IN ACCORDANCE WITH NFPA 13 INCLUDING BRANCH

LINE RESTRAINT. CP SHALL BE 0.5 PER NFPA 13.

9. ALL SPRINKLER PIPING IN FINISHED AREAS SHALL BE CONCEALED FROM VIEW.

10. PROVIDE INSPECTION AND HYDROSTATIC TESTS IN ACCORDANCE WITH NFPA 13

AND SPECIFICATION 21 13 13.00 10.

11. SPARE SPRINKLERS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13.

HYDRAULIC DATA PLATES SHALL BE PROVIDED AT THE RISER AND ABOVE THE

FIRE SPRINKLER CABINET.

12. A PRESSURE RELIEF VALVE SHALL BE PROVIDED AT EACH RISER.

13. PROVIDE A NOMINAL CLEARANCE OF 2 IN AROUND PIPES 3.5 IN AND

SMALLER, AND PROVIDE A NOMINAL CLEARANCE OF 4 IN AROUND PIPES 4 IN

AND LARGER PASSING THROUGH CONCRETE / MASONRY WALLS OR FLOORS.

14. THE FIRE SUPPRESSION SYSTEM IS CONCEPTUAL. THE CONTRACTOR SHALL

PROVIDE SHOP DRAWINGS. THE CONTRACTOR SHALL COORDINATE WITH

THE ARCHITECTURAL'S CEILING PLAN FOR THE SPRINKLER'S EXACT

LOCATION.

15. THE FIRE SUPPRESSION SYSTEM CONTRACTOR IS TO PROVIDE A COMPLETE

ENGINEERED SYSTEM, COMPLETE WITH CALCULATIONS AND FINAL DESIGN

DRAWINGS SIGNED AND SEALED BY AN INDIVIDUAL THAT HAS OBTAINED

NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES

(NICET LEVEL III AUTOMATIC SPRINKLER SYSTEMS) CERTIFICATION IN

ACCORDANCE WITH THE APPLICABLE NFPA CODES. NFPA 13 AUTOMATIC

SPRINKLER SYSTEM. THE DRAWINGS SHALL HAVE THE QCFPE REVIEW STAMP

PRIOR TO SUBMITTING TO THE GOVERNMENT FPE.

16. SIDE OUTLET TEES USING RUBBER GASKET FITTINGS AND HOLECUT

MECHANICAL "TEE'S" ARE PROHIBITED.

17. THE INSPECTOR'S TEST CONNECTION SHALL BE PROVIDED WITH A

REMOVABLE END CAP ON THE WET PIPE SYSTEM. FOR THE HANGAR BAY

WET PIPE SPRINKLER SYSTEM, LOCATE THE INSPECTOR'S TEST CONNECTION

AT THE RISER. TEST STATIONS ARE NOT PERMITTED IN THE HANGAR BAY.

18. PROVIDE LABEL TAG INDICATING "NORMALLY OPEN" OR "NORMALLY CLOSED"

ON ALL VALVES INCLUDING AND NOT LIMITED TO ALL RISER AND TRIM,

SECTIONAL VALVES, INSPECTORS TEST VALVES AND DRAINS.

19. PROVIDE SPERATE HARD-WIRED ELECTRIC CIRCUITS FOR THE PUMP

CONTROLLER, ENGINE STARTING SYSTEM BATTERY CHARGER AND HARD-

WIRED ELECTRIC CIRCUIT FOR THE ENGINE BLOCK HEATER.

20. CONTRACTOR SHALL NOT INSTALL ANY FIRE SPRINKLER PIPING THAT

CROSSES OVER OR PASSES THROUGH ANY ELECTRICAL ROOM OR

COMMUNICATION ROOM.

21. SPRINKLERS FOR THE COMMUNICATIONS ROOM SHALL BE SIDEWALLS WITH

GUARDS. SPRINKLER AND PIPING IN THE ELECTRIC ROOM SHALL COMPLY

WITH NFPA 70, ARTICLE 110.

FIRE SPRINKLER SYSTEM NOTES:

1. THE SPRINKLER SYSTEM DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH

NFPA 13-2016, UFC 4-211-01 AND SPECIFICATION SECTION 21 13 13.00 10 AND 21 30.00.

THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL SPRINKLER SYSTEM

COMPONENTS AND COORDINATE WITH THE VARIOUS TRADES.

2. ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM APPROVED.

3. AUTOMATIC WET PIPE SPRINKLER PROTECTION SHALL BE PROVIDED THROUGHOUT

THE BUILDING AS SHOWN ON THE DRAWINGS.

4. WATER SUPPLY INFORMATION:

HYDRANT #325 ON WORCHESTER AVENUE

STATIC PRESSURE 73 PSI

RESIDUAL PRESSURE 20 PSI

FLOW AT RESIDUAL PRESSURE 3,755 GPM

HYDRANT #567 IN PARKING AREA

STATIC PRESSURE 73 PSI

RESIDUAL PRESSURE 20 PSI

FLOW AT RESIDUAL PRESSURE 4,645 GPM

A DIESEL PRIMARY FIRE PUMP IS PROVIDED WITHIN THE CREW QUARTERS TO

SUPPORT THE F-22 ALERT HANGAR.

PUMP PRESSURE: 110 PSI

PUMP FLOW: 2,000 GPM

5. THE SPRINKLER SYSTEM SHALL BE HYDRAULICALLY DESIGNED IN ACCORDANCE

WITH NFPA 13. SPRINKLER SYSTEM DESIGN CRITERIA SHALL BE AS FOLLOWS:

OFFICE AREAS

OCCUPANCY HAZARD CLASSIFICATION: LIGHT

SPRINKLER TYPE: QUICK RESPONSE

K-FACTOR: 5.6

SPRINKLER TEMPERATURE: ORDINARY

DESIGN DENSITY: 0.1 GPM/SF

DESIGN METHOD: AREA/DENSITY

DESIGN AREA: 1,500 SF

OUTSIDE HOSE STREAM: 250 GPM

DURATION: 60 MINUTES

STORAGE, TOOL ROOM, ELEC, MECH, & COMM ROOM

OCCUPANCY HAZARD CLASSIFICATION: ORDINARY

SPRINKLER TYPE: QUICK RESPONSE

K-FACTOR: 8.0

SPRINKLER TEMPERATURE: INTERMEDIATE

DESIGN DENSITY: 0.2 GPM/SF

DESIGN METHOD: AREA/DENSITY

DESIGN AREA: 2,500 SF

OUTSIDE HOSE STREAM: 250 LPM

DURATION: 60 MINUTES

HANGAR

OCCUPANCY HAZARD CLASSIFICATION: HANGAR FOR FUELED AIRCRAFT

SPRINKLER TYPE: QUICK RESPONSE

K-FACTOR: 5.6

SPRINKLER TEMPERATURE: 175°F

DESIGN DENSITY: 0.2 GPM/SF (SIMULTANEOUS WITH THE

FOAM SYSTEM DISCHARGE)

DESIGN METHOD: AREA/DENSITY

DESIGN AREA: 5,000 SF

OUTSIDE HOSE STREAM: 500 GPM

DURATION: 45 MINUTES

FIRE PUMP ROOM

OCCUPANCY HAZARD CLASSIFICATION: EXTRA HAZARD

SPRINKLER TYPE: STANDARD RESPONSE

K-FACTOR: 11.2

SPRINKLER TEMPERATURE: HIGH, 250-300°F,

DESIGN DENSITY: 0.3 GPM/SF

DESIGN METHOD: AREA/DENSITY

DESIGN AREA: 2,500 SF

OUTSIDE HOSE STREAM: 500 GPM

DURATION: 90 MINUTES

7/22/2019 Expiration Date of the License

JA

Y

THOMAS H IGASH

I

P

R

EG I S T ER

E D31715

S

R O

F

E

SS ION AL ENG IN

E E

R

T A T E

OF WASH IN

G T O

N

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C

K

IK

U Y

A M

A

O

L E

E

S C

O T

T R

J H

A R

A D

A

A

IA

J

H

IG

A S

H I

-0

-2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

-2

-2

F-001

F

IR

E P

R O

T E

C T

IO

N

S Y

S T

E M

N O

T E

S s b

-P

N

-B

N H

Q -F

-0

.d w g

A

M E

N D

M E

N T

/2

/1

J H raink Text Box raink Text Box raink Text Box 6/1/18

LIGHT HAZARD

ORDINARY HAZARD

FIRE SPRINKLER HAZARD LEGEND

SYMBOL DESCRIPTION

EXTRA HAZARD

B

A

PUMP ROOM

QC 232

BATH 1

QC 226

PILOT #2

QC 227

MAINT QTRS #4

QC 219

MAINT QTRS #3

QC 218

MAINT QTRS #2

QC 217

MAINT QTRS #1

QC 216

MECH

QC 215

ELEC

QC 205

COMM

QC 204

BATH 2

QC 230

PILOT #4

QC 231

PILOT #1

QC 225

LAUNDRY

QC 224

JANITOR

QC 222

WOMEN'S

QC 223

MEN'S

QC 221

SECURE ROOM

QC 207

WTT

QC 206

MAINT STOR

QC 211

SUPER FLIGHT

QC 231

LAV/ NAV

QC 208

PANTRY

QC 203

EXERCISE ROOM

QC 214

LOCKER ROOM

QC 212

HALLWAY #2

QC 220

KITCHEN

QC 202

MULTI-PURPOSE

ROOM

QC 201

READY ROOM

QC 200

HALLWAY #1

QC 211

PILOT #3

QC 229

HALLWAY 1A

QC 228

OPTION #1

PROVIDE WET PIPE FIRE

SPRINKLER PROTECTION

WITHIN THIS BOUNDARY

B

A

FX421

A4

FIRE SPRINKLER

WET PIPE RISER

LOCATION UNDER

BID OPTION

6" UNDERGROUND

FIRE SPRINKLER

PIPING, SEE CIVIL

FOR CONTINUATION

6 HEAD TEST

HEADER

PUMP ROOM

QC 232

BATH 1

QC 226

PILOT #2

QC 227

MAINT QTRS #4

QC 219

MAINT QTRS #3

QC 218

MAINT QTRS #2

QC 217

MAINT QTRS #1

QC 216

MECH

QC 215

ELEC

QC 205

COMM

QC 204

BATH 2

QC 230

PILOT #4

QC 231

PILOT #1

QC 225

LAUNDRY

QC 224

JANITOR

QC 222

WOMEN'S

QC 223

MEN'S

QC 221

SECURE ROOM

QC 207

WTT

QC 206

MAINT STOR

QC 211

SUPER FLIGHT

QC 231

LAV/ NAV

QC 208

PANTRY

QC 203

EXERCISE ROOM

QC 214

LOCKER ROOM

QC 212

HALLWAY #2

QC 220

KITCHEN

QC 202

MULTI-PURPOSE

ROOM

QC 201

READY ROOM

QC 200

HALLWAY #1

QC 211

PILOT #3

QC 229

OPTION #1

FIRE SPRINKLER

WET PIPE RISER

LOCATION IF

OPTION #1 IS NOT

TAKEN

HALLWAY 1A

QC 228

ALL PIPING FOR SECURE

ROOMS SHALL ENTER

OVER THE DOORWAY AND

SHALL BE GROUNDED

FIRE DEPARTMENT

CONNECTION

FIRE DEPARTMENT

CONNECTION LOCATION IF

OPTION #1 IS NOT TAKEN

OPTION #1

LEGEND

7/22/2019 Expiration Date of the License

JA

Y

THOMAS H IGASH

I

P

R

EG I S T ER

E D31715

S

R O

F

E

SS ION AL ENG IN

E E

R

T A T E

OF WASH IN

G T O

N

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C

K

IK

U Y

A M

A

O

L E

E

S C

O T

T R

J H

A R

A D

A

A

IA

J

H

IG

A S

H I

-0

-2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

A s i n d ic a t e d

-2

-2

FX121

C R

E W

Q U

A R

T E

R S

F

IR

E

S P

R

IN

K L E

R A

N D

H A

Z A

R D

C L A

S S

IF

IC

A T

IO

N

P L A

N S s b

-P

N

-B

N H

Q -F

X

.d w g

PLAN NORTH

0' 12'4' 8'

SCALE: 1/8" = 1'-0"

16' 20' 24'

1/8" = 1'-0" A1

FIRE SPRINKLER HAZARD CLASSIFICATION PLAN - CREW QUARTERS

1/8" = 1'-0"

A4

FIRE SPRINKLER PLAN - CREW QUARTERS

2. CREW QUARTERS

A

M E

N D

M E

N T

J H

410230

A

B3

FX431

F T

R F

M C

P F

S C

P

SS

FV

AT

6" FOAM INDUCTOR

6" PRESSURE

REDUCING VALVE

WET SPRINKLER RISER

FOR HANGAR

10" STRAINER

OS&Y VALVE WITH

TAMPER SWITCH (TYP)

OS&Y VALVE WITH

TAMPER SWITCH (TYP)

TO WET SPRINKLER

SYSTEM IN HANGAR

TO FOAM

GENERATORS

PRV AND FOAM

TEST HEADER

WITH 6-2-1/2" HOSE

VALVES

FOAM ROOM

AH 301

12" FIRE PUMP

WATER SUPPLY,

SEE CIVIL FOR

CONTINUATION

6" HIGH CONC

HOUSEKEEPING PAD

TO WET SPRINKLER

SYSTEM IN FOAM ROOM

10" PRESSURE

REDUCING VALVE

FIRE DEPARTMENT

CONNECTION FOR

HANGAR

CHECK VALVE

SINGLE FIRE DEPARTMENT

CONNECTION FOR FOAM ROOM

WET SPRINKLER RISER

FOR FOAM ROOM

CHECK VALVE

REDUCER

UNIT NO. TYPE

TANK

DIAMETER

REMARKS

ATMOSPHERIC VERTICAL,

DOUBLE WALLED, HIGH DENSITY

CROSS-LINKED POLYETHYLENE

53"

TANK VOLUME

500 GALLONS

FOAM TANK

TANK SIZED FOR A 15 MINUTE DISCHARGE PLUS 60

GALLONS BASED ON A SYSTEM "SUPPLY" CALCULATION

AT

TANK

HEIGHT

79"

UNIT NO. TYPE PRESSURE REMARKS

TOP REPAIRABLE SURGE

SUPPRESSOR

275 PSI

TANK VOLUME

80 GALLONS

SURGE SUPPRESSOR SCHEDULE

PIPING TO SURGE ARRESTOR SHALL BE PROVIDED WITH

AN OS&Y VALVE AND TAMPER SWITCH

SS

TYPE REMARKS

SOLENOID OPERATED AND ASSOCIATED ABORT FUNCTION TRIM, FLOW CONTROL VALVE.

ACTIVATION OF THE ABORT SWITCH SHALL CLOSE THE DELUGE VALVE. ONCE THE ABORT

SWITCH IS RELEASED THE FLOW SHALL CONTINUE.

SIZE

6"

FLOW CONTROL VALVE SCHEDULE

FV

GROUND FLOOR

0' - 0"

FOAM ROOM

AH 301

10"ø

SS

FV

TO PRV AND FOAM TEST HEADER

TO WET SPRINKLER

SYSTEM IN HANGAR

TO WET

SPRINKLER

SYSTEM IN

FOAM ROOM

6" ALARM

CHECK VALVE

OS&Y VALVE (TYP)

OS&Y VALVE (TYP)

10" STRAINER10" PRESSURE

REDUCING VALVE

6" PRESSURE

REDUCING VALVE

2-1/2" ALARM

CHECK VALVE

OS&Y VALVE (TYP)

CHECK VALVE

FOR FDC

CHECK VALVE

FDC FOR HANGAR

OPTION #1

LEGEND

7/22/2019 Expiration Date of the License

JA

Y

THOMAS H IGASH

I

P

R

EG I S T ERE

D31715

S

R O

FE SS ION AL ENG IN

E

E R

T A T E

OF WASH ING

T O

N

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C

K

IK

U Y

A M

A

O

L E

E

S C

O T

T R

J H

A R

A D

A

A

IA

J

H

IG

A S

H I

-0

-2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

A s i n d ic a t e d

-2

-2

FX431

F

IR

E S

U P

P R

E S

S

IO

N E

N L A

R G

E D

F O

A M

R O

O M

P L A

N S

E C

T

IO

N A

N D

S C

H E

D U

L E

S s b

-P

N

-B

N H

Q -F

X

.d w g

1/2" = 1'-0" B1

FIRE SUPPRESSION ENLARGED FOAM ROOM

PLAN NORTH

0' 3'1' 2'

SCALE: 1/2" = 1'-0"

4' 5' 6'

1/2" = 1'-0" B3

FIRE SUPPRESSION FOAM ROOM LONGITUDINAL SECTION

OPTION #1

3. ALERT HANGAR

A

M E

N D

M E

N T

/2

/1

J H raink Text Box 6/1/18 raink Text Box raink

C

SB

SB

P F

C

F

F

C

C

C

C

C

C

C

C

VS

PS

AHU

VSVS VSVS

VS

C

F

SB

C

SB

C

SB

C

SB

SB

C

SB

C

C

C

C

F

F

C

C

FACP FTR

F

F A

N T

FEP

F

AHU

CO

FIRE ALARM CONTROL PANEL

B

A

PRPT CSPUMP ROOM

QC 232

BATH 1

QC 226

PILOT #2

QC 227

MAINT QTRS #4

QC 219

MAINT QTRS #3

QC 218

MAINT QTRS #2

QC 217

MAINT QTRS #1

QC 216

MECH

QC 215

ELEC

QC 205

COMM

QC 204

BATH 2

QC 230

PILOT #4

QC 231

PILOT #1

QC 225

LAUNDRY

QC 224

JANITOR

QC 222

WOMEN'S

QC 223

MEN'S

QC 221

SECURE ROOM

QC 207

WTT

QC 206

MAINT STOR

QC 211

SUPER FLIGHT

QC 231

LAV/ NAV

QC 208

PANTRY

QC 203

EXERCISE ROOM

QC 214

LOCKER ROOM

QC 212

HALLWAY #2

QC 220

KITCHEN

QC 202

MULTI-PURPOSE

ROOM

QC 201

READY ROOM

QC 200

HALLWAY #1

QC 211

PILOT #3

QC 229

OPTION #1

HALLWAY 1A

QC 228

ALL WIRING FOR SECURE

ROOMS SHALL ENTER AT

THIS POINT. CONDIUT

SHALL BE PROVIDED WITH

DIELECTRIC BREAK.

OS

OS

OS

OS

OS

OS

OS

OS OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

PAPA SYSTEM

OPTION #1

LEGEND

7/22/2019 Expiration Date of the License

JA

Y

THOMAS H IGASH

I

P

R

EG I S T ER

E D31715

S

R O

F

E

SS ION AL ENG IN

E E

R

T A T E

OF WASH IN

G T O

N

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C

K

IK

U Y

A M

A

O

L E

E

S C

O T

T R

J H

A R

A D

A

A

IA

J

H

IG

A S

H I

-0

-2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

A s i n d ic a t e d

-2

-2

FA121

C R

E W

Q U

A R

T E

R S

F

IR

E

A L A

R M

P L A

N s b

-P

N

-B

N H

Q -F

A

.d w g

PLAN NORTH

0' 12'4' 8'

SCALE: 1/8" = 1'-0"

16' 20' 24'

1/8" = 1'-0"A1

FIRE ALARM PLAN - CREW QUARTERS

2. CREW QUARTERS

A

M E

N D

M E

N T

/2

/1

J H

A

M E

N D

M E

N T

J H

410239

W P

W P

W P

WP

B

F S

C P

W P

WP

B

W P

W P

SV

W P

W P

W P

WP

B

1 2

A

B

C

A

M

D

A M

D

AMD

DMA

WP

WP

WP

WP WP WP

WP WP WP

WP

WP

WP

ALERT HANGAR

AH 300

FOAM ROOM

AH 301

RPS

OPTION #1

LEGEND

7/22/2019 Expiration Date of the License

JA

Y

THOMAS H IGASH

I

P

R

EG I S T ER

E D31715

S

R O

F

E

SS ION AL ENG IN

E E

R

T A T E

OF WASH IN

G T O

N

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C

K

IK

U Y

A M

A

O

L E

E

S C

O T

T R

J H

A R

A D

A

A

IA

J

H

IG

A S

H I

-0

-2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

A s i n d ic a t e d

-2

-2

FA131

A L E

R T

H A

N G

A R

A

F

IR

E

S U

P P

R E

S S

IO

N

A L A

R M

P L A

N

A L E

R T

H A

N G

A R s b

-P

N

-B

N H

Q -F

A

.d w g

PLAN NORTH

1/8" = 1'-0" A1

FIRE SUPPRESSION ALARM PLAN - ALERT HANGAR - A

0' 12'4' 8'

SCALE: 1/8" = 1'-0"

16' 20' 24'

NO SCALE

KEY PLAN-A

OPTION #1

3. ALERT HANGAR

A

M E

N D

M E

N T

/2

/1

J H

A

M E

N D

M E

N T

J H

410240

W

W P

W P

B

WP

W P

WP

B

W P

W P

W P

W P

W P

B

WP

2 3

A

B

C

A

M

D

A M

D

AMD

DMA

WP

WP

WP

WP

WP

WP

WP WP WP

WP WP WP

ALERT HANGAR

AH 300

OPTION #1

LEGEND

7/22/2019 Expiration Date of the License

JA

Y

THOMAS H IGASH

I

P

R

EG I S T ER

E D31715

S

R O

F

E

SS ION AL ENG IN

E E

R

T A T E

OF WASH IN

G T O

N

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C

K

IK

U Y

A M

A

O

L E

E

S C

O T

T R

J H

A R

A D

A

A

IA

J

H

IG

A S

H I

-0

-2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

A s i n d ic a t e d

-2

-2

FA132

A L E

R T

H A

N G

A R

B

F

IR

E

S U

P P

R E

S S

IO

N

A L A

R M

P L A

N

A L E

R T

H A

N G

A R s b

-P

N

-B

N H

Q -F

A

.d w g

1/8" = 1'-0" A1

FIRE SUPPRESSION ALARM PLAN - ALERT HANGAR - B

PLAN NORTH

0' 12'4' 8'

SCALE: 1/8" = 1'-0"

16' 20' 24'

NO SCALE

KEY PLAN-B

OPTION #1

3. ALERT HANGAR

A

M E

N D

M E

N T

/2

/1

J H

A

M E

N D

M E

N T

J H

410241

VISUAL OR

AUDIO/VISUAL

DEVICE

MANUAL FIRE

ALARM PULL

STATION

AUDIO

DEVICE

IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR

AUDIO DEVICES WHILE LEAVING A MINIMUM OF 6 INCHES BETWEEN THE

CEILING AND THE TOP OF THE AUDIO DEVICE, THE DEVICE SHALL BE

MOUNTED AT 6 INCHES BELOW CEILING MEASURED TO THE TOP OF THE

DEVICE.

IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR

VISUAL OR AUDIO/VISUAL DEVICE, THE DEVICE SHALL BE MOUNTED AT

6 INCHES BELOW CEILING MEASURED TO THE BOTTOM OF THE DEVICE.

FIRE

FIRE

FINISHED FLOOR

60"

ANTENNA

PROVIDE SUPPORT FOR

VERTICAL PORTION OF

RACEWAY ABOVE ROOF

CONDUIT CLAMP

LIGHTING

ARRESTOR WITH

ENCLOSURE, SEE

DETAIL C3/FA501

1" GALVANIZED

RIGID CONDUIT

TO INDIVIDUAL

GROUNDING ROD PER

NEC

COPPER WIRE SHALL

NOT BE SMALLER

THAN #10 PER NEC

EXTERIOR WALL

GRADE

ROOF

RADIO FIRE ALARM

TRANSCEIVER

CONC SLAB

CONNECT TO

INDIVIDUAL

GROUNDING ROD

PROVIDE #6 BONDWIRE FROM

INDIVIDUAL GROUNDING ROD TO

BUILDING GROUNDING SYSTEM

MECH

RM

FuT

T O

F R

O M

P E

A K

O F

R O

O F

SIDE VIEW - WEATHERPROOF

ENCLOSURE

WEATHERPROOF ENCLOSURE

STATIC DISCHARGE UNIT

GROUND BUSHING

COAXIAL CABLES

ARE NOT SHOWN

#10 COPPER

7/22/2019 Expiration Date of the License

JA

Y

THOMAS H IGASH

I

P

R

EG I S T ER

E D31715

S

R O

F

E

SS ION AL ENG IN

E E

R

T A T E

OF WASH IN

G T O

N

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C

K

IK

U Y

A M

A

O

L E

E

S C

O T

T R

J H

A R

A D

A

A

IA

J

H

IG

A S

H I

-0

-2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

A s i n d ic a t e d

-2

-2

FA501

F

IR

E A

L A

R M

D E

T A

IL

S s b

-P

N

-B

N H

Q -F

A

.d w g

NOT TO SCALEC4

TYPICAL MOUNTING FOR FIRE ALARM DEVICES

NOT TO SCALEA1

ANTENNA TRANSCEIVER

NOT TO SCALEC3

LIGHTNING ARRESTOR DETAIL

A

M E

N D

M E

N T

J H

410245

ACTIVATION OF SMOKE DETECTOR AT THE FIRE ALARM PANELS

ACTIVATION OF A MANUAL FIRE ALARM PULL STATION

SYSTEM INPUT

A N N U N C

IA

TE S

U

PER

VIS

O R Y A

LA

R M

O N F

M C P

AN

N U N C

IA

TE T

R O U

BLE

A T F

M C P

A N N U N C

IA

TE A

LA

R M

A T F

M C P

X

X

X

X

CREW QUARTERS AND SENTRY ALOHA FIRE ALARM SYSTEM SEQUENCE OF OPERATIONS

SYSTEM OUTPUT

X

X

A B C D E F

FIR

E A

LA

R M

T R

AN

SM

IT

TER

TR

AN

SM

IT

S

IG

N A L

TO

F

IR

E D

EPA

R

TM

EN

T V

IA

T

H E R

AD

IO

ALARM - SPRINKLER SYSTEM WATERFLOW SWITCH

ALARM - MANUAL PULL STATION

ALARM - CEILING SMOKE DETECTOR

RADIO FIRE ALARM TRANSCEIVER ZONES

A C

TIV

ATE T

H E A

U D

IO

A

LA

R M

C

IR

C U

IT

S

A C

TIV

ATE F

IR

E A

LA

R M

V

IS

U

AL

D

EVIC

ES A

N D

B R O

AD

C

AST F

IR

E A

LA

R M

E

VAC

U

ATIO

N M

ESSAG

E

G H I J

XACTIVATION OF DUCT SMOKE DETECTOR AT AN AHU X

A B C D E F G H I J

K

K

ACTIVATION OF SPRINKLER SYSTEM TAMPER SWITCH X X

SYSTEM TROUBLE X X

FIRE PUMP RUNNING X XX

FIRE PUMP TROUBLE

FIRE PUMP CONTROLLER SWITCH MISSET

X X

X X

SUPERVISORY - DUCT SMOKE DETECTOR

SUPERVISORY - SPRINKLER TAMPER SWITCH

TROUBLE - COMMON

SPARE

X

X

X

SPARE

SPARE

SPARE

SUPERVISORY - FIRE PUMP CONTROLLER

S H U

TD

O W

N A

IR

H

AN

D

LI

N G U

N

IT

(S

X

ACTIVATION OF A SPRINKLER WATER FLOW/PRESSURE SWITCH X X X X

ALARM - FIRE PUMP RUNNING

SPARE

SPARE

TU

R N O

N L

IG

H

TIN

G A

T O C C U

PAN

C Y S

EN

SO

R

X

X

X

X

TU

R N O

FF

PA S

YS

TEM

X

X

X

X

ACTIVATION OF SMOKE DETECTOR WITH SOUNDER BASE WITHIN A SLEEPING ROOM

ACTIVATION OF CO DETECTOR

X

X X

A C

TI

VATE S

O U N D

ER

B A

SE W

IT

H

IN

A

SS

O C . S

LE

EPIN

G R

O O M

A C

TI

VA

TE T

EM

P O R

AL

FIR

E A

LA

R M

S

IG

N A L

AN

D

X

B R O

AD

C

AST C

AR

BO

N M

O N O X

ID

E M

ESSAG

E

X

ALARM - CARBON MONOXIDE

SPARE

X

OPTION #1

LEGEND

7/22/2019 Expiration Date of the License

JA

Y

THOMAS H IGASH

I

P

R

EG I S T ER

E D31715

S

R O

F

E

SS ION AL ENG IN

E E

R

T A T E

OF WASH IN

G T O

N

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C

K

IK

U Y

A M

A

O

L E

E

S C

O T

T R

J H

A R

A D

A

A

IA

J

H

IG

A S

H I

-0

-2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

-2

-2

FA601

F

IR

E A

L A

R M

S E

Q U

E N

C E

O F

O P

E R

A T

IO

N

S s b

-P

N

-B

N H

Q -F

A

.d w g

OPTION #1

OPTION #1

A

M E

N D

M E

N T

J H

410247

FIRE SUPPRESSION CONTROL PANEL MATRIX

O

M M

O N

F O

A M

/ W A

T E

R T

R O

U B

L E

S

IG

N A

L T

O F

M C

P A

N D

R E

C E

IV

IN

G S

T A

T

IO

N

DEPRESS FOAM STOP STATION BUTTON

RELEASE FOAM STOP STATION BUTTON

TROUBLE CONDITION

PRESSURE SWITCH ON FOAM / WATER RISER *

ANY TWO SIMULTANEOUS TRIPLE IR FLAME DETECTORS WITHIN THE PROTECTED ZONE **

SINGLE TRIPLE IR FLAME DETECTOR WITHIN THE PROTECTED ZONE **

MANUAL FOAM RELEASING STATION

O P

E N

C O

N T

R O

L V

A L V

E F

O R

F O

A M

/W A

T E

R S

Y S

T E

M

X

X

A U

D

IO

-V

IS

U A

L T

R O

U B

L E

I N

D

IC

A T

IO

N

B Y

A D

D R

E S

S

A U

D

IO

-V

IS

U A

L S

U P

E R

V

IS

O R

Y I N

D

IC

A T

IO

N

B Y

A D

D R

E S

S

G E

N E

R A

L F

IR

E

A L

A R

M S

IG

N

A L T

O F

M C

P A

N D

R E

C E

IV

IN

G S

T A

T I O

N

A U

D

IO

-V

IS

U A

L F

I R E

A L A

R M

S I N

D

IC

A T

IO

N

B Y

A D

D R

E S

S

F O

A M

/W A

T E

R R

E L E

A S

E S

IG

N

A L

T O

F M

C P

A N

D R

E C

E

IV

IN

G

S T

A T

I O N

SUPERVISORY CONDITIONS

C L O

S E

C O

N T

R O

L V

A L V

E F

O R

F O

A M

/W A

T E

R S

Y S

T E

M

DO NOT RELEASE THE CONTROL VALVE FROM THE PRESSURE SWITCH

TRIPLE IR ALARMS SHALL BE NON-LATCHING

C O

M M

O N

F O

A M

/ W A

T E

R S

U P

E R

V

IS

O R

Y S

IG

N

A L T

O F

M C

P A

N D

R E

C E

IV

IN

G S

T A

T

IO

N

E N

A B

L E

B L U

E B

E A

C O

N S

I N

H A

N G

A R

B A

Y

X

X X

X

X

X

X

X

X

X

X

X

X

ANNUNCIATE AT

LOCAL PANELS

NOTIFICATION AUXILLARY

FUNCTIONS

XX

X X X

X X D

IS

A

B L

E A

L A

R M

A N

D R

E L

E A

S

IN

G F

U N

C T

IO

N

S F

R O

M T

H E

T R

IP

L E

I R

D E

T E

C T

IO

N

FOAM SYSTEM DISABLE SWITCH *** X

PROVIDE A 2-POSITION NON-KEY OPERATED SWITCH LOCATED WITHIN THE FSCP ENCLOSURE, THAT WHEN ACTIVATED DISABLES THE RELEASING FUNCTION OF ALL OPTICAL FLAME DETECTORS IN THE HANGAR BAY THROUGH PROGRAMMING AT THE FSCP. WHEN THE SWITCH IS PLACED IN THE INHIBIT MODE. ONLY THE RELEASING FUNCTIONS OF THE OPTICAL FLAME DETECTORS ARE DISABLED WHILE LEAVING ALL OTHER FUNCTIONS OF THE FSCP OPERATIONAL. MONITOR THE INHIBIT SWITCH AT THE FSCP. PROVIDE A SUPERVISORY SIGNAL TO THE RECIEVING STATION INDICATING THE OPTICAL FLAME DETECTORS ARE INHIBITED. A TROUBLE SIGNAL IS NOT PERMITTED. LAVER THE SWITCH "INHIBIT OPTICAL FLAME DETECTION." PROVIDE ENGRAVED LABELS ON THE INHIBIT SWITCH INDICATING WHEN THE OPTICAL FLAME DETECTORS ARE IN "NORMAL" OR "INHIBIT" MODE.

X

IN

H

IB

IT

S W

IT

C

H S

U P

E R

V

IS

O R

Y S

IG

N

A L T

O F

A C

P A

N D

R E

C

IE

V

IN

G S

T A

T

IO

N I N

D

IC

A T

IN

G

T H

E O

P T

IC

A

L F

L A

M E

D E

T E

C T

O R

S A

R E

I N

H

IB

IT

E

D

X

OPTION #1

LEGEND

ACTIVATION OF CEILING SMOKE DETECTOR AT THE FIRE ALARM PANELS

ACTIVATION OF A MANUAL FIRE ALARM PULL STATION

SYSTEM INPUT

A N N U N C

IA

TE S

U

PER

VIS

O R Y A

LA

R M

O N F

M C P

AN

N U N C

IA

TE T

R O U

BLE

A T F

M C P

A N N U N C

IA

TE A

LA

R M

A T F

M C P

X

X

X

X

ALERT HANGAR FIRE ALARM SYSTEM SEQUENCE OF OPERATIONS

SYSTEM OUTPUT

X

X

A B C D E F

FIR

E A

LA

R M

T R

AN

SM

IT

TER

TR

AN

SM

IT

S

IG

N A L

TO

F

IR

E D

EPA

R

TM

EN

T V

IA

T

H E R

AD

IO

ALARM - SPRINKLER SYSTEM WATER FLOW/PRESURE SWITCH

ALARM - MANUAL PULL STATION

ALARM - CEILING SMOKE DETECTOR

RADIO FIRE ALARM TRANSCEIVER ZONES

A C

TIV

ATE T

H E A

U D

IO

A

LA

R M

C

IR

C U

IT

S

A C

TIV

ATE F

IR

E A

LA

R M

V

IS

U

AL

D

EVIC

ES A

N D

B R O

AD

C

AST F

IR

E A

LA

R M

E

VAC

U

ATIO

N M

ESSAG

E

A B C D E F

ACTIVATION OF SPRINKLER SYSTEM TAMPER SWITCH X X

SYSTEM TROUBLE X X

FIRE SUPPRESSION SYSTEM CONTROL PANEL ACTIVATES INTO ALARM

FIRE SUPPRESSION SYSTEM CONTROL PANEL ACTIVATES INTO SUPERVISORY

FIRE SUPPRESSION SYSTEM CONTROL PANEL ACTIVATES INTO TROUBLE

SUPERVISORY - SPRINKLER TAMPER SWITCH

TROUBLE - COMMON

ALARM - FIRE SUPPRESSION PANEL

X

X

ACTIVATION OF A SPRINKLER WATER FLOW/PRESSURE SWITCH X X X X

SUPERVISORY - FIRE SUPPRESSION PANEL

TROUBLE - FIRE SUPPRESSION PANEL

X

X

X

X

X

X

X X

SUPERVISORY- FSCP OPTICAL FLAME DETECTORS ARE INHIBITED

7/22/2019 Expiration Date of the License

JA

Y

THOMAS H IGASH

I

P

R

EG I S T ER

E D31715

S

R O

F

E

SS ION AL ENG IN

E E

R

T A T E

OF WASH IN

G T O

N

SHEET

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

US Army Corps of Engineers ® Honolulu District

A

B

C

D

1 2 3 4 5

D E

S

IG

N E

D B

Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

OF

M A

R K

D E

S C

R

IP

T

IO

N A

P P

R

D A

T E

J O

IN

T

B A

S E

P E

A R

L H

A R

B O

R

H

IC

K A

M H

A W

A

II

IN

K

A R

C H

L L C

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

S

IZ

E

A N

S I

D

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

F

IL

E N

A M

E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

W

A

-0

-D -0

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

H

IC

K A

M F

O R

C E

B A

S E

O

A H

U

H A

W A

II

F Y

K N

M D

F -2

F

IG

H

T E

R A

L E

R T

F A

C

IL

IT

Y

C

K

IK

U Y

A M

A

O

L E

E

S C

O T

T R

J H

A R

A D

A

A

IA

J

H

IG

A S

H I

-0

-2

I W

IL

E

I R

O A

D S

U

IT

E

H O

N O

L U

L U

H

I

P -5

-1

-2

-2

FA602

A L E

R T

H A

N G

A R

F

IR

E

S U

P P

R E

S S

IO

N

S E

Q U

E N

C E

O F

O P

E R

A T

IO

N

S s b

-P

N

-B

N H

Q -F

A

.d w g

OPTION #1

A

M E

N D

M E

N T

J H

410248

1 2

B

SHEET

A

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

410258 raink Rectangle raink

410265a

410265b

SHEET

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

410265c

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

410271

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

CQ 218

MAIN QTRS #4

CQ 217

MAIN QTRS #3

CQ 216

MAIN QTRS #2

CQ 215

MAIN QTRS #1

CQ 214

MECH

QC 219

HALLWAY #2

CQ 214

EXERCISE ROOM CQ 212

LOCKER ROOM

CQ 220

MEN'S

QC 221

JANITOR

CQ 222

WOMEN'S

CQ 227

PILOT #2

CQ 226

BATH #1

CQ 230

PILOT #1

CQ 223

LAUNDRY

CQ 224

PILOT #4

CQ 228

PILOT #3

CQ 229

BATH #2

CQ 227

HALLWAY #1

CQ 211

MAIN STOR

CQ 209

SUPER FLIGHT

410277

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

CQ 205

ELEC

CQ 206

WTT

CQ 204

COMM

CQ 203

PANTRY

CQ 202

KITCHEN

CQ 201

MULTI-PURPOSE ROOM

CQ 207

SECURE ROOM

CQ 200

READY ROOM

CQ 208

LAV/ NAV

QC 209

SUPER FLIGHT

410278 raink Text Box 6/1/18 raink Rectangle

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

410288 raink Rectangle raink

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

410289 raink Text Box 6/1/18

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

410290

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

410294

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

1. PROVIDE 3D PHOTO-REALISTIC AIR HANDLING UNIT GRAPHICS FOR THE DDC

PROGRAM. THE GRAPHICS SHOULD SHOW THE OVERALL UNIT WITH FILTERS,

COILS, FANS, PIPING, VALVES, ETC. WITH SYSTEM POINTS, SETPOINTS AND

CURRENT READINGS. PROVIDE A DRAWING OF THE PROPOSED 3D

PHOTO-REAELISTIC GRAPHICS FOR THE ENGINEERING DEPARTMENT TO

REVIEW AND APPROVE.

2. ALL CONTROL ITEMS SHOWN ON THE THIS CONTROL DRAWING SHALL BE

CONNECTED, PROGRAMMED AND BE SHOWN ON THE 3D PHOTO-REALISTIC

GRAPHIC DRAWING WITHIN THE DDC PROGRAM.

GRAPHIC NOTES:

DIFFERENTIAL

PRESSURE SWITCH

(TYP)

TO DDC

SYSTEM DC

COOLING

COIL

AIR HANDLING UNIT (AHU)

FAN STATUS CURRENT

SENSOR/SWITCH

TO DDC SYSTEM

DIGITAL CONTROLLER

(DC)

THERMOSTAT

(TYP)

EXISTING FIRE ALARM PANEL

OUTSIDE AIR

T1 T2

MOTORIZED DAMPER

(FOR AHU CQ-1 AND

CQ-2 ONLY)

410296 raink Rectangle raink

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

MAIN ELECTRIC AND WATER METERS CONNECTION

RF WATER METER

CREW QUARTERS BUILDING

MAIN ELECTRICAL METER

CREW QUATERS BUILDING

MAIN ELECTRICAL METER

CONNECTED TO THE BASE

EMI SYSTEM

THE MAIN ELECTRICAL AND WATER METERS SHALL COMPLY

WITH THE ADVANCED METERING INITIATIVE (AMI). THE MAIN

WATER METERS SHALL BE CONNECTED TO THE MAIN

ELECTRICAL METER VIA RF SIGNAL. SEE SPECIFICATION

SECTION 33 11 00 FOR MAIN WATER METER REQUIREMENTS.

SEE THE ELECTRICAL AND COMMUNICATION DRAWINGS AND

SPECIFICATIONS FOR THE REST OF THE AMI SYSTEM

REQUIREMENTS.

MAIN ELECTRIC AND WATER METERS COMMUNICATION

RF WATER METER

SENTRY ALOHA BUILDING

MAIN ELECTRICAL METER

SENTRY ALOHA BUILDING

MAIN ELECTRICAL METER

CONNECTED TO THE BASE

EMI SYSTEM

410297 raink Rectangle raink

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

410299 raink Text Box 6/1/18

B

C

D

1 2 3 4 5

SHEET

IDENTIFICATION

OF

410300 raink Rectangle raink

ELECTRICAL GENERAL NOTES

WORK INCLUDES INSTALLATION OF ALL ELECTRICAL SYSTEMS, COMPLETE

AND OPERATIONAL TO THE INTENT OF THE CONTRACT DOCUMENTS.

PERFORM ALL ELECTRICAL WORK IN ACCORDANCE WITH THE LATEST EDITION OF

THE NATIONAL ELECTRICAL CODE (NFPA 70), NATIONAL ELECTRICAL SAFETY CODE,

APPLICABLE INSTRUCTIONS OF MANUFACTURERS OF EQUIPMENT AND MATERIALS

SUPPLIED FOR THE PROJECT, AND ALL ORDINANCES, RULES AND POLICIES OF THE

FEDERAL, STATE AND COUNTY IN WHICH THE WORK IS TO BE PERFORMED.

PROVIDE COMPRESSION TYPE FITTINGS FOR EMT CONDUITS. PROVIDE

GALVANIZED MALLEABLE IRON FOR ALL OTHER FITTINGS.

SIZE ALL CONDUITS PER THE NATIONAL ELECTRICAL CODE UNLESS SHOWN

OTHERWISE ON THE DRAWINGS.

PROVIDE SOLID COPPER, 600 VOLT INSULATION TYPE THHN, THWN POWER

CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS #10 AND SMALLER.

PROVIDE AND INSTALL AN INSULATED GREEN GROUNDING CONDUCTOR,

SIZED PER TABLE 250-122 OF THE NATIONAL ELECTRICAL CODE, FOR ALL

CIRCUITS. INSTALL THIS CONDUCTOR IN ALL RACEWAYS INCLUDING THOSE

INSTALLED FOR SWITCH LEGS AND ATTACH TO THE DEVICE, LUMINAIRE, OR

EQUIPMENT USING A SUITABLE GROUNDING LUG.

PROVIDE AND INSTALL ALL JUNCTION AND PULLBOXES REQUIRED FOR THE

INSTALLATION OF ELECTRICAL DEVICES AND EQUIPMENT, WHETHER OR NOT

SPECIFICALLY INDICATED ON THE PLANS. SIZE BOXES IN ACCORDANCE WITH

THE NATIONAL ELECTRICAL CODE.

COORDINATE WITH OTHER TRADES AND CONFIRM THE EXACT EQUIPMENT

LOCATIONS AND THE LOCATIONS AND MOUNTING HEIGHTS OF ALL POWER

AND TELEPHONE DEVICES BEFORE ROUGHING IN.

SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS AND SLABS USING U.L.

LISTED FIRE RATED SEALANT TO MAINTAIN THE INTEGRITY OF THE FIRE RATING.

SEAL AND PAINT ALL PENETRATIONS THROUGH WALLS AND SLABS TO MATCH

ADJACENT SURFACE.

OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER BEFORE

MAKING ANY PENETRATIONS THROUGH STRUCTURAL MEMBERS OR

FIRE RATED WALLS AND SLABS.

CONFIRM THE TYPE OF CEILING BEING INSTALLED PRIOR TO ORDERING

LUMINAIRE TRIMS FOR PROPER COORDINATION. CATALOG NUMBERS

ARE GIVEN FOR A GENERIC LUMINAIRE AND MAY NOT EXPRESSLY

CONFIRM TYPE OF CEILING OR OPENING PROVIDED BY OTHER TRADES.

SHOULD PROJECT CONDITION REQUIRE REARRANGEMENT OF WORK,

MARK SUCH CHANGES ON THE AS-BUILT DRAWINGS.

UPDATE THE CIRCUIT DIRECTORIES ON EXISTING PANELS, REFLECTING

THE CIRCUIT ARRANGEMENT AS IT WAS ACTUALLY INSTALLED.

CONCEAL ALL CONDUITS UNLESS OTHERWISE NOTED. THE MINIMUM

SIZE IS 3/4 INCH. EMT MAY BE USED FOR INDOOR CONCEALED CONDUIT

RUNS 2" OR SMALLER.

COORDINATE CIRCUIT BREAKER SIZING WITH MECHANICAL EQUIPMENT

REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING

BREAKERS. PROVIDE CORRECTLY COORDINATED BREAKER AS REQUIRED.

ELECTRICAL CONTRACTOR SHALL COORDINATE POWER

REQUIREMENTS WITH THE AIR CONDITIONING CONTROLS

CONTRACTOR. ELECTRICAL POWER SHALL BE PROVIDED FOR UV

LIGHTS, TERMINAL UNITS, DAMPER MOTORS, ETC. AS REQUIRED.

ALL EQUIPMENT AND APPARATUS SHALL BE CAPABLE OF FITTING IN THE SPACES

LOCATED WHILE MEETING THE MANUFACTURER'S RECOMMENDED ACCESS

REQUIREMENTS AND WORKING CLEARANCES. REVIEW ALL SPACES WHERE

EQUIPMENT IS TO BE INSTALLED PRIOR TO ORDERING OF EQUIPMENT AND NOTIFY

THE ENGINEER OF ANY INADEQUATE CLEARANCES OR CONDITIONS THAT WILL

PREVENT THE PROPER INSTALLATION, MAINTENANCE, AND OPERATIONS OF THE

EQUIPMENT.

4.

3.

2.

1. THE DEMOLITION PLAN IS INTENDED TO SHOW THE GENERAL SCOPE

OF WORK AND DOES NOT NECESSARILY SHOW EVERY DEVICE, BOX,

CONDUIT, PANEL, ETC. TO BE REMOVED. FIELD VERIFY OTHER

ELECTRICAL SERVICE THAT MAY BE ENCOUNTERED DURING

DEMOLITION AND REMOVE OR RE-ROUTE THESE ITEMS AS REQUIRED.

REMOVE ALL UNUSED WIRING AND CONDUIT BACK TO SOURCE FROM

DEMOLITION AREA NOT CONCEALED IN CONCRETE OR PLASTER,

INCLUDING WIRING DISCONNECTED AND NOT RE-USED UNDER THIS

CONTRACT AND WIRING UNCOVERED BY DEMOLITION UNLESS

OTHERWISE NOTED.

ALL REMAINING JUNCTION AND PULL BOXES SHALL BE ACCESSIBLE AS

PER NATIONAL ELECTRICAL CODE (N.E.C.). THE CONTRACTOR SHALL

MOVE EXISTING BOXES, ETC. AS REQUIRED BY NEW CONSTRUCTION.

PRIOR TO ELECTRICAL REMOVAL WORK, DE-ENERGIZE PANEL TO BE REMOVED

TWO WORKING DAYS BEFORE STARTING WORK TO VERIFY PANEL CIRCUIT ARE

CONFINED WITHIN THE REMOVAL WORK AREA. IF PANEL BRANCH CIRCUITS

EXTEND INTO OTHER OCCUPIED AREAS. COORDINATE WITH CONTRACTING

OFFICER TO HAVE THE CIRCUITS RELOCATED.

5. ALL ELECTRICAL DEVICES TO REMAIN SHALL BE RECONNECTED TO A

NEARBY ELECTRICAL DISTRIBUTION SOURCE IN THE EVENT THAT ITS

EXISTING ELECTRICAL DISTRIBUTION SOURCE IS REMOVED.

ALL OUTDOOR ELECTRICAL EQUIPMENT SHALL BE FACTORY PAINTED

PER HICKAM AFB REQUIREMENTS.

6. REMOVE AND OR RELOCATE EXISTING ITEMS IN WAY OF NEW

CONSTRUCTION.

7. PATCH ANY OPENINGS CREATED BY DEMOLITION WORK THAT WILL NOT

BE USED FOR NEW WORK.

8. PATCH, PAINT, AND REPAIR ALL EXPOSED SURFACES CREATED BY

DEMOLITION WORK.

CONTRACTOR SHALL IDENTIFY AND REROUTE ALL TELECOM CABLES AND

INFRASTRUCTURE THAT HINDER CONSTRUCTION IN…