ISS 15R0001 USAYPG - Technical Exhibit 2 - Workload History.docx

DOCX document 35 KB Posted

Attached to
Installation Support Services for Yuma Proving Ground, AZ Federal contract opportunity
Solicitation number
W9124R-15-R-0001
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Joint Base Lewis-McChord

About this file

TE 2

View the file

Other files for this federal contract opportunity

Other files attached to Installation Support Services for Yuma Proving Ground, AZ, newest first.
File Type Posted
W9124R-15-R-0001-0005_conformed.pdf PDF
Attachment_1_PWS_15R0001_YPG-ISS_-_5-19-17_v7L.pdf PDF
W9124R-15-R-0001-0004.pdf PDF
Attachment_1_PWS_15R0001_YPG-ISS_-_5-18-17_v5L.pdf PDF
Attachment_1_PWS_15R0001_YPG-ISS_-_5-9-17_v6L.pdf PDF
revised_Technical_Exhibit_3_-_Performance_Requirements_Summary_-_20170504.pdf PDF
Response_to_Vendor_Questions__8_5-10-17_.pdf PDF
Response_to_Vendor_Questions__7_5-4-17_.pdf PDF
Attachment_1_PWS_15R0001_YPG-ISS_-_4-27-17_v1L.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_1_-_Real_Property_Inventory_-_20170426.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_2_-_Workload_History_-_20170426.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_24_-_Boiler_Size.docx DOCX document
Attachment_5_NEW__5-2-17.xlsx XLSX spreadsheet
Attach__6_YPG_CBA_2015_2020.pdf PDF
Response_to_Vendor_Questions__6_posted_5-2-17_.pdf PDF
Response_to_Vendor_Questions__4_posted_4-25-17.docx DOCX document
Response_to_Vendor_Questions__3-_Yuma_PG_ISS_4-21-17.pdf PDF
Response_to_Vendor_Questions__2.pdf PDF
ISS 15R0001 USAYPG - Technical Exhibit 5 - Equipment In Place.docx DOCX document
Attachment_1_PWS_15R0001_YPG-ISS_-_3-30-17_v5L.pdf PDF
ISS_15T0001_USAYPG_-_Technical_Exhibit_23.pdf PDF
ISS 15R0001 USAYPG - Technical Exhibit 19 - Cathodic Protection System Locations.docx DOCX document
ISS 15R0001 USAYPG - Technical Exhibit 4 - Contractor Occupied Facilities.docx DOCX document
Attachment_4_-_DD254.pdf PDF
Attach_L_-_3_SKtr_Consent_for_Release.docx DOCX document
ISS 15R0001 USAYPG - Technical Exhibit 22 - Government Furnished Property.docx DOCX document
ISS 15R0001 USAYPG - Technical Exhibit 13 - Water Pumping Booster Stations.docx DOCX document
Attachment_5_YPG_Price_Breakdown_-_for_evaluation.xlsx XLSX spreadsheet
ISS 15R0001 USAYPG - Technical Exhibit 17 - POL Facilities Locations and Equipment.docx DOCX document
ISS 15R0001 USAYPG - Technical Exhibit 16 - Roads and Test Courses.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_3_-_Performance_Requirements_Summary_-_20170327_v2L.pdf PDF
Attachment_3_Vehicle_list.xlsx XLSX spreadsheet
W9124R-15-R-0001.pdf PDF
ISS 15R0001 USAYPG - Technical Exhibit 15 - Grounds Inventory.docx DOCX document
Attachment_5_YPG_Price_Breakdown_-_for_evaluation_v2.xlsx XLSX spreadsheet
ISS 15R0001 USAYPG - Technical Exhibit 11 - Boiler-Heater Visible Emisions Inspection Checklist.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_2_-_Workload_History.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_6_-_Deliverables_20161011.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_16_-_Roads_and_Test_Courses.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_1_-_Real_Property_Inventory.docx DOCX document
PWS_-_ISS_15R0001_USAYPG_-_3-2-17.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_9_-_ICE_Visible_Emisions_Inspection_Checklist.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_10_-_Boiler_Tune-Up_Form.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_13_-_Water_Pumping_Booster_Stations.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_17_-_POL_Facilities_Locations_and_Equipment.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_5_-_Equipment_In_Place.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_18_-_POL_Facilities_Bi-Monthly_Checklist.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_3_-_Performance_Requirements_Summary_-_20161005.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_7_-_Electrical_Substations.docx DOCX document
ISS_15R0001_USAYPG_-_Technical_Exhibit_20_-_Cathodic_Protection_System_PM_Checklist.docx DOCX document
Show all 50

Installation Support Services for Yuma Proving Ground, AZ has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNICAL EXHIBIT 2

WORKLOAD HISTORY

The DPW Workload Data is known to vary significantly with an increase or decrease in the mission, changing security and environmental requirements, or variations in funding level. However, based upon FY12 through FY15 averages, the following is an estimated workload per year.

Number of Services:

Shop
SO
SJO
PM
TOTAL
HVAC (H)
711
430
2,857
3998
PLUMBING (J)
719
388
1,709
2,816
ELECTRICAL (K)
1,091
267
1,881
3,239
CARPENTRY (M)
1,089
521
904
2,513
PEST CONTROL (P)
149
258
0
407

GROUNDS

MAINTENANCE (R)

142
1237
0
1,378
HEAVY EQUIPMENT (V)
424
235
0
660
HIGH VOLTAGE (X)
82
54
44
180
TOTAL
4,406
3,390
7,394
15,190

Number of Labor Hours

Shop
SO
SJO
PM
TOTAL
HVAC (H)
2,723
7,124
3,729
13,576
PLUMBING (J)
3148
3,403
1,919
8,470
ELECTRICAL (K)
4,748
2,784
3,317
10,849
CARPENTRY (M)
5,185
6227
723
12,135
PEST CONTROL (P)
240
1,913
0
2,153

GROUNDS

MAINTENANCE (R)

1672
17043
0
19,552
HEAVY EQUIPMENT (V)
6,984
13,649
0
20,633
HIGH VOLTAGE (X)
960
558
669
2,187
TOTAL
25,660
52,702
11,194
89,555

Cost of Materials

Shop
SO
SJO
PM
TOTAL
HVAC (H)
$145,193
$11,782
$2,866
$159,842
PLUMBING (J)
$44,577
$5,153
$5,676
$55,407
ELECTRICAL (K)
$78,684
$383
$5,319
$84,387
CARPENTRY (M)
$73,683
$9,070
$64
$82,817
PEST CONTROL (P)
$487
$1,913
$0
$2,467

GROUNDS

MAINTENANCE (R)

$4,081
$24,248
$0
$28,328
HEAVY EQUIPMENT (V)
$116
$1,555
$0
$1,671
HIGH VOLTAGE (X)
$8,427
$4
$802
$9,233
TOTAL
$355,250
$54,702
$14,728
$424,152

There is no workload history for fire extinguisher. It is estimated that this function will take 1.0 man-years of labor.

There is no workload history for recycling. It is estimated that this function will take 2.0 man-years of labor.

The workload history from the POL Facility Maintenance is 1.0 man-years of labor and $2,500 materials.

The workload history from the Cathodic Protection System Maintenance is 1.0 man-years labor and $5,000 materials.

File details come from the government source that posted it. Updated .