About this file

Revised M Drawings

View the file

Other files for this federal contract opportunity

Other files attached to CLR039b Long Range Discrimination Radar Construction Package #2 ECF, Clear AFS, AK, newest first.
File Type Posted
01_19_30_02_29_Attachment_f.pdf PDF
01_19_30_02_29_Attachment_g.pdf PDF
01_50_00_02_00_Attachment_a.pdf PDF
01_19_30_02_29_Attachment_a.pdf PDF
05_40_00.02_00.pdf PDF
08_44_23.02_00.pdf PDF
G-100003E_Location_and_Vicinity_Map.pdf PDF
01_19_30.02_29.pdf PDF
01_11_00.02_00.pdf PDF
28_23_23.02_10.pdf PDF
09_29_00.02_00.pdf PDF
Revised_TY_Drawings.pdf PDF
EG100101E_SITE_PLAN_-_GROUNDING.pdf PDF
Schedule_of_Drawings_AM__3_Sheet_2.pdf PDF
23_05_93.02_00.pdf PDF
01_45_35.02_00.pdf PDF
W911KB18R0006_AM_3.pdf PDF
Schedule_of_Drawings_AM__3_Sheet_1.pdf PDF
01_50_00.02_00.pdf PDF
Final_Presentation--Pre-Proposal_Site_Visit--20180515_Slide_5_Date_Corrections.pdf PDF
01_33_29.02_00.pdf PDF
Revised_E-1_Drawings.pdf PDF
Revised_T_Drawings.pdf PDF
Revised_Security_Drawings.pdf PDF
08_88_36.02_00.pdf PDF
G-100005E_Contractor_Laydown_Areas.pdf PDF
Site_Visit_Sign_In_Sheet.pdf PDF
W911KB18R0006_AM_2.pdf PDF
33_71_02.02_00.pdf PDF
EG100101E_-_SITE_PLAN_-_GROUNDING.pdf PDF
01_91_10.02_29.pdf PDF
28_23_23.02_10.pdf PDF
28_20_01.02_10.pdf PDF
Revised_Site_Plan_Drawings.pdf PDF
26_21_00.02_00.pdf PDF
Final_Presentation--Pre-Proposal_Site_Visit--20180515.pdf PDF
C_Drawing_revisions.pdf PDF
Revised_E_Drawings.pdf PDF
A_Drawing_Revisions.pdf PDF
28_20_00.02_00.pdf PDF
Revised_E-9_Drawings.pdf PDF
W911KB18R0006_AM_1.pdf PDF
JA_for_Vindictor_LRDR_ECF_Redacted.pdf PDF
JA_Edwards_EST3_fire_Panel_CP_2_ECF_Redacted.pdf PDF
CLR_LRDR_CP2_Rev2_RTA_Drawings_22x34.pdf PDF
CP2_RTA_SPECS_V3_CLR039_18-0410.pdf PDF
CP2_RTA_SPECS_V2_CLR039_18-0410.pdf PDF
SPECS_V2-4_CLR039_18-0410.pdf PDF
CP2_RTA_SPECS_V4_CLR039_18-0410.pdf PDF
W911KB18R0006.pdf PDF
Show all 50

CLR039b Long Range Discrimination Radar Construction Package #2 ECF, Clear AFS, AK has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPACE TEMPERATURE CONTROL SYSTEMS

PERFORMANCE REQUIREMENTS

1. PROVIDE CONTROL SYSTEMS TO MAINTAIN THE REQUIRED HEATING,

VENTILATING, AND COOLING (HVAC) CONDITIONS, AND PLUMBING

REQUIREMENTS BY PERFORMING THE FUNCTIONS AND SEQUENCES OF

OPERATIONS INDICATED. POINTS LIST PROVIDED IN SEQUENCE ARE

MINIMUM REQUIRED POINTS. PROVIDE ADDITIONAL POINTS TO COMPLY

WITH THE DRAWING REQUIREMENTS AND SEQUENCE AS NEEDED.

2. BUILDING SYSTEMS SHALL BE UNOCCUPIED MODE UNLESS

OCCUPANCY SENSOR LOCATED IN ENTRY CONTROL OFFICE #105 IS

TRIGGERED, THEN SYSTEMS SHALL BE IN OCCUPIED MODE.

SEQUENCE OF OPERATION

1. EQUIPMENT SHALL BE CONTROLLED BY BMS SYSTEM AND SHALL BE

COORDINATED WITH DEVICE IDENTIFIERS ON CONTROL SYSTEM

DIAGRAMS. THIS SECTION INCLUDES SEQUENCE OF OPERATION FOR

THE FOLLOWING:

ELECTRIC HEATING

1. AIR CURTAINS (AIC-90341001 AND AIC-90341002)

2. BASEBOARD RADIATION (FTH-90322001 THRU FTH-90322004)

3. CABINET UNIT HEATERS (CUH-90322001 AND CUH-90322002)

4. DUCT HEATING COIL (PHC-90341001)

5. HEATING COIL (HC-90341001)

ELECTRIC COOLING

1. AIR CONDITIONING EVAPORATING UNIT (ACU-90332001)

2. AIR CONDITIONING CONDENSING UNIT (COND-90333002)

3. CONDENSING UNIT (COND-90333001)

VENTILATION

1. AIR HANDLING UNITS (AHU-90341001)

2. BATHROOM EXHAUST FANS (EF-90341001 AND EF-90341002)

PLUMBING

1. WATER HEATER (WH-90312001)

2. DOMESTIC WATER CIRCULATION PUMP(P-90312001)

3. FIRE WATER CIRCULATION PUMP (P-90352001)

SEQUENCE OF OPERATION

BMS GENERAL

1. THE CONTRACTOR SHALL COLLABORATE WITH THE CONTRACTING

OFFICER DIRECTLY TO DETERMINE THE CONTRACTING OFFICER'S

PREFERENCE FOR NAMING CONVENTIONS, ETC. BEFORE ENTERING

THE DATA INTO THE SYSTEM. ALL SUGGESTED SET POINTS AND

SETTINGS ARE ADJUSTABLE.

2. ALL POINTS OUTLINED SHALL BE ADDRESSABLE THROUGH THE BMS

SYSTEM. ALL POINTS SHALL BE PROGRAMMED AT THE HOST

COMPUTER AND GRAPHICS SHALL BE PREPARED.

3. ALL WORK OUTLINED HERE SHALL BE CONTROLLED BY THE BMS

UNLESS OTHERWISE NOTED.

ELECTRIC HEATING

1. BASEBOARD RADIATION (FTH-90322001 THRU FTH-90322004)

a. BMS SHALL CYCLE ELECTRIC BASEBOARD RADIATION

ON/OFF AS REQUIRED TO MAINTAIN SETPOINT

TEMPERATURE.

2. DOOR AIR CURTAINS (AIC-90341001)

a. A DOOR MICRO-SWITCH SHALL CYCLE ELECTRIC AIR

CURTAIN HEATER ON/OFF. WHEN OUTSIDE AIR

TEMPERATURE IS BELOW 50 DEGREES F, HEATER SHALL

CYCLE ON WHEN DOOR OPENS AND OFF WHEN DOOR

CLOSES. HEATER SHALL ALSO CYCLE TO MAINTAIN SPACE

TEMPERATURE TO 4 DEG F BELOW FTH UNITS.

b. THE FOLLOWING SHALL BE SHOWN ON THE GRAPHICAL

USER INTERFACE:

POINTS TYPE ALARM

SPACE TEMPERATURE AI CRITICAL

SPACE SETPOINT - -

COMMAND ON/OFF DO -

FAN COMMAND DO -

ELECTRIC COOLING

1. AIR CONDITIONING EVAPORATING UNIT (ACU-90332001) AND

CONDENSING UNIT (COND-90333002).

a. AIR CONDITIONING EVAPORATING AND CONDENSING UNITS

SHALL OPERATE TOGETHER WITH MANUFACTURER'S SELF-

CONTAINED PACKAGED CONTROLS TO MAINTAIN SPACE

SETPOINT TEMPERATURE.

2. CONDENSING UNIT (COND-90333001)

b. CONDENSING UNIT, COND-90333001, SHALL OPERATE TO

ACHIEVE AIR HANDLING UNIT, AHU-90341001, SUPPLY AIR

COOLING TEMPERATURE SETPOINT.

c. HE FOLLOWING SHALL BE SHOWN ON THE GRAPHICAL

USER INTERFACE:

POINTS TYPE ALARM

UNIT STATUS DI -

GENERAL ALARM DI MAINTENANCE

SEQUENCE OF OPERATION

VENTILATION

1. AIR HANDLING UNITS (AHU-90341001)

a. AIR HANDLING UNIT, AHU-90341001 SHALL OPERATE WITH AN

ELECTRONICALLY COMMUTATED MOTOR (ECM), WHICH WILL BE USED FOR

SOFT STARTS. THE VENTILATION SYSTEM HAS NO VARIABLE-AIR-VOLUME

(VAV) BOXES.

b. AIR HANDLING UNIT SHALL OPERATE IN WARM-UP, OCCUPIED, AND UNOCCUPIED MODES OF OPERATION.

BUILDING OCCUPANCY SENSORS SHALL INDICATE MODES.

c. SUPPLY AIR DISCHARGE TEMPERATURE SET POINT SHALL

BE 68 DEGREES F (ADJUSTABLE), UNLESS OUTSIDE AIR

TEMPERATURE IS BELOW ZERO DEGREES F, THEN SUPPLY

AIR DISCHARGE TEMPERATURE SHALL BE 72 DEGREES F

(ADJUSTABLE).

d. WARM-UP MODE OF OPERATION

1. UPON ACTIVATION BY BMS CONTROLLER, SUPPLY FAN

SHALL OPERATE IN WARM-UP MODE. IF THE AVERAGE SPACE

TEMPERATURE (AS CALCULATED BY THE BMS CONTROLLER AS THE

AVERAGE OF ALL SPACE TEMPERATURES SERVED BY A GIVEN AHU)

IS BELOW 68 DEGREES F, THE SUPPLY FAN SHALL OPERATE IN

HEATING WARM-UP MODE. IF AVERAGE SPACE TEMPERATURE IS

ABOVE 72 DEGREES F, SUPPLY FAN SHALL GO DIRECTLY TO

OCCUPIED MODE.

2. WARM-UP MODE SHALL BE INITIATED TO ENTER OCCUPIED MODE

AS SCHEDULED

3. IN HEATING WARM-UP MODE, BMS CONTROLLER SHALL CLOSE

OUTSIDE AIR AND RELIEF AIR DAMPERS, OPEN RETURN AIR DAMPER,

AND MODULATE THE ELECTRIC HEATING COIL, HC-90341001,

DOWNSTREAM OF THE AIR HANDLING UNIT, AHU-90341001 TO ACHIEVE

THE SUPPLY AIR TEMPERATURE SETPOINT.

e. OCCUPIED MODE OF OPERATION

1. SUPPLY FAN SHALL OPERATE CONTINUOUSLY.

2. HEATING MODE (OUTDOOR TEMPERATURE LESS THAN

50 DEGREES F): OUTSIDE AIR DAMPER SHALL BE IN MINIMUM

POSITION AND OUTSIDE AIR WILL ROUTE THROUGH PREHEAT

COIL, PHC-90341001. THE PREHEAT COIL WILL MAINTAIN AN

OUTLET TEMPERATURE OF 35 DEGREES F (ADJUSTABLE). AIR

WILL BE ROUTED TO THE RETURN AIR MIXING BOX, THEN

THROUGH AHU-90341001. RELIEF AIR DAMPER SHALL BE CLOSED

AND RETURN AIR DAMPER SHALL BE FULLY OPEN. IF THE SUPPLY

AIR SETPOINT IS NOT ATTAINABLE, THE BMS CONTROLLER SHALL

MODULATE THE ELECTRIC HEATING COIL, HC-90341001,

DOWNSTREAM OF AHU-90341001, OR ACTIVATE CONDENSING UNIT

COND-90333001, AND DX COOLING COIL TO ACHIEVE THE SUPPLY

AIR TEMPERATURE SETPOINT.

3. ECONOMIZER MODE (OUTDOOR TEMPERATURE BETWEEN 50-75

DEGREES F): BMS CONTROLLER SHALL MODULATE THE OUTSIDE

AIR AND RETURN AIR DAMPERS TO MAINTAIN SUPPLY AIR

DISCHARGE TEMPERATURE. EXHAUST AIR DAMPER SHALL

MODULATE OPEN ALONG WITH OUTSIDE AIR DAMPER,

BUT LAG BY 75 CFM (I.E. OUTSIDE AIR DAMPER STARTS AT

75 CFM MINIMUM POSITION, WHILE EXHAUST AIR DAMPER STARTS

AT FULLY CLOSED). IF THE SUPPLY AIR SET POINT IS NOT

ATTAINABLE, THE BMS CONTROLLER SHALL ACTIVATE

CONDENSING UNIT COND-90333001, AND DX COOLING COIL

CC-90341001 TO ACHIEVE THE SUPPLY AIR TEMPERATURE

SETPOINT.

4. COOLING MODE (OUTDOOR TEMPERATURE GREATER

THAN 75 DEGREES F): BMS CONTROLLER SHALL

MODULATE THE OUTSIDE AIR DAMPER TO MINIMUM

POSITION, AND RETURN DAMPERS SHALL OPEN IN

SEQUENCE. EXHAUST AIR DAMPER SHALL MODULATE

CLOSED. THE BMS CONTROLLER SHALL ACTIVATE

CONDENSING UNIT CU-1, AND DX COOLING COIL TO

ACHIEVE THE SUPPLY AIR TEMPERATURE SETPOINT.

5. MINIMUM OUTSIDE AIR DAMPER POSITION SHALL BE

SET ACCORDING TO THE FOLLOWING SCHEDULE:

a) AHU-90341001 = 75 CFM (WITH OUTSIDE AIR

TEMPERATURE > 50 DEGREES F)

b) AHU-90341001 = 75 CFM (WITH OUTSIDE AIR

TEMPERATURE < 50 DEGREES

f. UNOCCUPIED MODE OF OPERATION.

1. AHU-1 SHALL HAVE A MANUAL OVERRIDE SWITCH TO

TURN AHU-1 OFF/ON.

2. IN EITHER MANUAL OVERRIDE OFF OR IN THE

PROGRAMMED SEQUENCE UNOCCUPIED MODE, AHU-

90341001 SUPPLY FAN SHALL BE OFF.

3. OUTSIDE AIR AND EXHAUST AIR DAMPERS SHALL BE

CLOSED, RETURN AIR DAMPER SHALL OPEN, HEATING

COIL, HC-90341001 SHALL BE OFF, AND CONDENSING

UNIT, COND-90333001 SHALL BE OFF.

g. COOLING COIL (CC-9041001)

1. THE BMS CONTROLLER SHALL ACTIVATE THE

CONDENSING UNIT, COND-90322001, AS REQUIRED TO

MAINTAIN THE DX COOLING COIL SUPPLY AIR

SETPOINT TEMPERATURE OF 55 DEGREES F.

h. FILTER

1. DIFFERENTIAL PRESSURE ACROSS THE FILTER SHALL

BE INPUT TO THE BMS CONTROLLER.

2. BMS CONTROLLER SHALL INITIATE MAINTENANCE

ALARM WHEN THE DIFFERENTIAL PRESSURE ACROSS

THE FILTER RISES ABOVE 1.0 I.W.G., ADJUSTABLE.

3. THE FOLLOWING BMS MAINTENANCE ALARM SHALL BE

PROVIDED AT THE CONTROL PANEL:

a) FILTER MAINTENANCE ALARM.

i. OTHER FEATURES

1. A LOW-LIMIT TEMPERATURE SENSOR SHALL BE IN THE

SUPPLY AIR DUCTWORK DOWNSTREAM OF THE FAN

AND INPUT TO THE BMS CONTROLLER. UPON LOW-

LIMIT, BMS CONTROLLER SHALL INITIATE SHUT DOWN:

THE OUTSIDE AIR DAMPER SHALL CLOSE, RETURN AIR

DAMPER SHALL OPEN, HEATING COIL HC-90341001

SHALL GO TO FULL HEAT, AND ALARM SHALL

ACTIVATE. INITIAL SETPOINT, 40 DEGREES F,

ADJUSTABLE.

2. PROVIDE AN EMERGENCY SHUT-OFF SWITCH TO SHUT

OUTDOOR AIR DAMPERS AND STOP FAN MOTORS IN A

LOCKABLE BOX AT LOCATION SHOWN ON DRAWINGS.

a) THE FOLLOWING SHALL BE SHOWN ON THE

GRAPHICAL USER INTERFACE:

POINTS TYPE ALARM

FAN ENABLE DO -

FAN STATUS (ON/OFF) DI CRITICAL

OUTSIDE AIR TEMPERATUREAI -

OUTSIDE AIR CFM AO -

SUPPLY AIR TEMPERATURE AI MAINTENANCE/FREEZE

SUPPLY AIR TEMP SETPOINTAO -

EXHUAST AIR CFM AO -

SUPPLY AIR CFM AO -

RETURN AIR TEMPERATURE AO -

MIXED AIR TEMPERATURE AO -

O/A DAMPER POSITION AO -

EXHAUST AIR DAMPER PSTN AO -

RETURN AIR DAMPER PSTN AO -

FILTER STATUS DI MAINTENANCE

LOW TEMP ALARM AI MAINTENANCE

LOW LIMIT TEMP. ALARM DO -

HIGH DUCT SP SHUTDOWN DO -

2. EXHAUST FANS (EF-90341001 AND EF-90341002)

a. EXHAUST FANS SHALL OPERATE IN OCCUPIED MODES OF

OPERATION. BMS SHALL DICTATE WARM-UP, OCCUPIED AND

UNOCCUPIED MODES OF OPERATION.

b. OCCUPIED MODE OF OPERATION

1. LIGHT SWITCHES SHALL CYCLE EXHAUST FANS, EF-

90341001 AND EF-9031002 ON/OFF.

2. IN HEATING WARM-UP MODE, BMS CONTROLLER SHALL

CLOSE OUTSIDE AIR AND EXHAUST AIR DAMPERS,

OPEN RETURN AIR DAMPER, AND MODULATE THE

ELECTRIC HEATING COIL, HC-90341001, DOWNSTREAM

OF THE AIR HANDLING UNIT, AHU-90341001 TO ACHIEVE

THE RETURN AIR TEMPERATURE SETPOINT.

PLUMBING

1. WATER HEATER (WH-90312001)

a. PACKAGED CONTROLLER SHALL PROVIDE 140

DEGREES F HOT WATER.

b. GENERAL WATER HEATER FAILURE ALARM SHALL

GENERATE A MAINTENANCE ALARM THROUGH BMS.

2. DOMESTIC WATER CIRCULATION (P-90312001)

a. DOMESTIC WATER CIRCULATION PUMP (P-90312001)

AND FIRE WATER CIRCULATION PUMP (P-90352001)

CIRCULATION PUMPS SHALL RUN CONTINUOUSLY.

PUMP FAILURE:

1. PUMP STATUS FOR FAILURE ALARM PURPOSES SHALL BE

DETERMINED THROUGH THE PRESSURE MONITORING ACROSS

THE SUPPLY AND CIRCULATION LINES

2. IF THE PUMP FAILS OR DOES NOT PROVE ON, THEN GENERATE A

“CRITICAL PUMP FAILURE ALARM AT THE BMS.

3. THE FOLLOWING SHALL BE SHOWN ON THE GRAPHICAL USER

INTERFACE:

POINTS TYPE ALARM

WATER HEATER GEN. FAILURE DI MAINTENANCE

DOM. WATER CIRC. PUMP ENABLE DO -

DOM. WATER CIRC. PUMP STATUS DI CRITICAL

FIRE WATER CIRC. PUMP ENABLE DO -

FIRE WATER CIRC. PUMP STATUS DI CRITICAL

D E

P

A R

T M

E N

T O

F D

E F

E

N S

E

MISSIL

E D

E F

E N

S E

A

G

ENCY

D ra w in g

F il e N a m e

D w g S c a le

P lo t S c a le

D a te

D ra w n

R E

S

ID

E N

T E

N G

IN

E

E R

P R

IM

E

C O

N T

R A

C T

O R

S u b m it te d

D e s ig n e d

R e v ie w e d

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

A N

C H

O R

A G

E A

L A

S K

A

C O

R P

S O

F E

N G

IN

E

E R

S

D a te

S T

A T

E C

IT

Y

C O

N T

R A

C T

O R

C O

N T

R A

C T

N O

R e c o m m e n d e d

A p p ro v e d

Reference number:

HGFEDCBA

A S

N O

T E

D

P L O

T T

E D

O N

US Army Corps of Engineers ®

Alaska District

M D

A

C L R b

P D

C I N

C

E N

G

IN

E E

R S

G

A M

B E

L L S

T S

U

IT

E

A N

C H

O R

A G

E

A K

A N

C

-7

-3

A

E C

C

N O

T F

O R

C O

N S

T R

U C

T

IO

N

/1

/2

:5

:1

A

M C

U s e rs

\m ic h a e lb a rt e ll\

D o c u m e n ts

\C L

R L

R D

R

E C

F M

-D M

M ic h a e lB a rt e ll.

rv t

AM#3 M-903801E

S E

Q U

E N

C E

O F

O P

E R

A T

IO

N

S

L O

N G

R A

N G

E D

IS

C

R

IM

IN

A

T

IO

N R

A D

A R

C L E

A R

A F

S A

L A

S K

A

R S

W

:1

C

LR

_L R

D R

_ E C

F _M

-D M

M E

B

C P

F

W K

B -1

-R

-0

.0 .1

C O

N S

T R

U C

T

IO

N P

A C

K A

G E

V O

L U

M E

R

D P

A F

-1

- 3

-0

S y m

A c ti o n

D e s c ri p ti o n D a te

A p p v d

A

M

A

M M

E N

D M

E N

T

/1

M J L

REV CONTROLLER TAG DEVICE TAG I/O DESCRIPTION I/O TYPE REMARKS

GENERAL

ECF BMS OCCUPANCY SENSORS STATUS DI

ELECTRIC HEATING

ECF BMS FTH-90332001/ FTH-90332002/ AIC-90341002 SPACE TEMPERATURE AI CRITICAL

ECF BMS FTH-90332001/FTH-90332002 SPACE SETPOINT -

ECF BMS FTH-90332001 COMMAND ON/OFF DO

ECF BMS FTH-90332002 COMMAND ON/OFF DO

ECF BMS AIC-90341002 DOOR MAGNET STATUS DI

ECF BMS AIC-90341002 FAN COMMAND DO

ECF BMS FTH-90332003/ FTH-90332004/ AIC-90341001 SPACE TEMPERATURE AI CRITICAL

ECF BMS FTH-90332003/FTH-90332004 SPACE SETPOINT -

ECF BMS FTH-90332003 COMMAND ON/OFF DO

ECF BMS FTH-90332004 COMMAND ON/OFF DO

ECF BMS AIC-90341001 DOOR MAGNET STATUS DI

ECF BMS AIC-90341001 FAN COMMAND DO

ECF BMS CUH-90322001/CUH-90322002 SPACE SETPOINT -

ECF BMS CUH-90322001 FAN COMMAND DO

ECF BMS CUH-90322002 FAN COMMAND DO

ELECTRIC COOLING

ECF BMS ACU-90332001 ANTI-RECYCLE TIMER STATUS DI

ECF BMS ACU-90332001 ANTI-COINCIDENT TIMER STATUS DI

ECF BMS ACU-90332001 EVAPORATOR RUN STATUS DI MAINTENANCE

ECF BMS ACU-90332001 FAN STATUS DI MAINTENANCE

ECF BMS ACU-90332001 LOAD AND UNLOAD TIMER STATUS DI

ECF BMS ACU-90332001 DISCHARGE AIR TEMP RESET AO

ECF BMS COND-90333001 CONDENSER STATUS DI MAINTENANCE

ECF BMS COND-90333001 GENERAL ALARM DI MAINTENANCE

ECF BMS COND-90333002 CONDENSER STATUS DI MAINTENANCE

ECF BMS COND-90333002 GENERAL ALARM DI MAINTENANCE

VENTILATION

ECF BMS AHU-90341001/ CC-90341001/ HC-90341001 SPACE TEMPERATURE AI CRITICAL--MECH RM SPACE TEMPERATURE

ECF BMS AHU-90341001 FAN COMMAND DO

ECF BMS AHU-90341001 FAN STATUS (ON/OFF) DI CRITICAL

ECF BMS AHU-90341001/ CC-90341001/ HC-90341001 SUPPLY AIR TEMPERATURE AI MAINTENANCE/FREEZE

ECF BMS AHU-90341001 SUPPLY AIR TEMPERATURE SETPOINT -

ECF BMS AHU-90341001 SUPPLY AIR CFM AO

ECF BMS AHU-90341001 MERV 8 FILTER STATUS DI MAINTENANCE

ECF BMS AHU-90341001 MERV 8 WINTER FILTER STATUS DI MAINTENANCE

ECF BMS CC-90341001 CC-90341001 VALVE CONTROL AO

ECF BMS CC-90341001 CC-90341001 VALVE POSITION AI

ECF BMS HC-90341001 HC-90341001 ENABLE DO

ECF BMS VENTILATION SYSTEM MERV 8 SUMMER FILTER STATUS DI

ECF BMS VENTILATION SYSTEM OUTSIDE AIR DAMPER POSITION AO

ECF BMS VENTILATION SYSTEM OUTSIDE AIR TEMPERATURE AI

ECF BMS VENTILATION SYSTEM OUTSIDE AIR CFM AO

ECF BMS VENTILATION SYSTEM PHC-90341001 ENABLE DO

ECF BMS VENTILATION SYSTEM RETURN AIR DAMPER POSITION AO

ECF BMS VENTILATION SYSTEM MIXED AIR TEMPERATURE AI

ECF BMS VENTILATION SYSTEM MIXED AIR CFM

ECF BMS VENTILATION SYSTEM RELIEF AIR DAMPER POSITION AO

ECF BMS VENTILATION SYSTEM RELIEF AIR CFM AO

ECF BMS VENTILATION SYSTEM LOW TEMP ALARM AI MAINTENANCE

ECF BMS VENTILATION SYSTEM LOW LIMIT TEMPERATURE ALARM AI

ECF BMS VENTILATION SYSTEM HIGH DUCT STATIC PRESSURE SHUTDOWN DO

ECF BMS EF-90341001 FAN ENABLE DO

ECF BMS EF-90341001 FAN STATUS (ON/OFF) DI CRITICAL

ECF BMS EF-90341002 FAN ENABLE DO

ECF BMS EF-90341002 FAN STATUS (ON/OFF) DI CRITICAL

ECF BMS EF-90341001/2 EXHAUST AIR DAMPER POSITION AO

PLUMBING

ECF BMS WH-90312001 WATER HEATER GENERAL FAILURE DI MAINTENANCE

ECF BMS P-90312001 PUMP COMMAND DO

ECF BMS P-90312001 PUMP STATUS DI

ECF BMS P-90312001 DOMESTIC WATER PRESSURE DIFFERENTIAL DI MAINTENANCE

ECF BMS POWER SERVICE METER STATUS DI MAINTENANCE

ELECTRIC HEAT TRACE

ECF BMS VENT THROUGH ROOF PIPE TEMPERATURE AI

ECF BMS VENT THROUGH ROOF HEAT TRACE STATUS DI

ECF BMS ROOF DRAIN PIPE TEMPERATURE AI

ECF BMS ROOF DRAIN HEAT TRACE STATUS DI

ECF BMS OVERFLOW ROOF DRAIN PIPE TEMPERATURE AI

ECF BMS OVERFLOW ROOF DRAIN HEAT TRACE STATUS DI

ECF BMS FIRE WATER PIPE TEMPERATURE AI

ECF BMS FIRE WATER HEAT TRACE STATUS DI

FIRE PROTECTION

ECF BMS P-90352001 PUMP COMMAND DO

ECF BMS P-90352001 PUMP STATUS DI

ECF BMS P-90352001 FIRE WATER PRESSURE DIFFERENTIAL DI MAINTENANCE

D E

P

A R

T M

E N

T O

F D

E F

E

N S

E

MISSIL

E D

E F

E N

S E

A

G

ENCY

D ra w in g

F il e N a m e

D w g S c a le

P lo t S c a le

D a te

D ra w n

R E

S

ID

E N

T E

N G

IN

E

E R

P R

IM

E

C O

N T

R A

C T

O R

S u b m it te d

D e s ig n e d

R e v ie w e d

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

A N

C H

O R

A G

E A

L A

S K

A

C O

R P

S O

F E

N G

IN

E

E R

S

D a te

S T

A T

E C

IT

Y

C O

N T

R A

C T

O R

C O

N T

R A

C T

N O

R e c o m m e n d e d

A p p ro v e d

Reference number:

HGFEDCBA

A S

N O

T E

D

P L O

T T

E D

O N

US Army Corps of Engineers ®

Alaska District

M D

A

C L R b

P D

C I N

C

E N

G

IN

E E

R S

G

A M

B E

L L S

T S

U

IT

E

A N

C H

O R

A G

E

A K

A N

C

-7

-3

A

E C

C

N O

T F

O R

C O

N S

T R

U C

T

IO

N

/1

/2

:5

:1

A

M C

U s e rs

\m ic h a e lb a rt e ll\

D o c u m e n ts

\C L

R L

R D

R

E C

F M

-D M

M ic h a e lB a rt e ll.

rv t

AM#3 M-903802E

C O

N T

R O

L P

O

IN

T S

L O

N G

R A

N G

E D

IS

C

R

IM

IN

A

T

IO

N R

A D

A R

C L E

A R

A F

S A

L A

S K

A

R S

W

:1

C

LR

_L R

D R

_ E C

F _M

-D M

C S

B

C P

F

W K

B -1

-R

-0

.0 .1

C O

N S

T R

U C

T

IO

N P

A C

K A

G E

V O

L U

M E

R

D P

A F

-1

- 3

-0

S y m

A c ti o n

D e s c ri p ti o n D a te

A p p v d

A

M

A

M M

E N

D M

E N

T

/1

M J L

3 3

Sheets
M-903801E - SEQUENCE OF OPERATIONS
M-903802E - CONTROL POINTS
M-903802E - CONTROL POINTS.pdf
Sheets
M-903801E - SEQUENCE OF OPERATIONS
M-903802E - CONTROL POINTS

File details come from the government source that posted it.