A_Drawing_Revisions.pdf
PDF 342 KB Posted
- Attached to
- CLR039b Long Range Discrimination Radar Construction Package #2 ECF, Clear AFS, AK Federal contract opportunity
- Solicitation number
- W911KB18R0006
View the file
Other files for this federal contract opportunity
Show all 50
CLR039b Long Range Discrimination Radar Construction Package #2 ECF, Clear AFS, AK has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SD
SD
SD
SD
SD
RD ORD
AC B
A-903501E
SLOPE = 1/2" PER 1'-0" SLOPE = 1/2" PER 1'-0"
TO
S
HE
AT
HI
NG
'-0
TO
S
HE
AT
IN
G
'-4 5/
8"
TO
S
HE
AT
HI
NG
'-0 5/
8"
A-903502E
4'
- 8
A-903501E
A-903501E
SIM
A-903501E
A-903501E
A-903501E
A-903501E
SIM
A-903501E
VTR
9' - 7"
A-903503E
SIM
A-903503E
SIM
MAX
4' - 0"
MECHANICAL EQUIPMENT- REFER
TO MECAHINCAL DRAWINGS
MECHANICAL EQUIPMENT- REFER
TO MECHANICAL DRAWINGS
A-903503E
SIM
A-903503E
SIMRING SENSOR
ROOF PLAN LEGEND ROOF PLAN GENERAL NOTES
1. WIND LOADING: ALL EXTERIOR ROOFING ASSEMBLIES TO COMPLY WITH DESIGN WIND PRESSURES FOR SPECIFIED
LOADING REQUIREMENTS, INCLUDING ALL PARAPET COPING AND RELATED METAL FLASHINGS. SEE STRUCTURAL
FOR PERFORMANCE REQUIREMENTS.
2. ALL ROOF PLANS SHOW MOST MAJOR MECHANICAL AND ELECTRICAL ROOF-MOUNTED EQUIPMENT AND DEVICES.
SEE MECHANICAL AND ELECTRICAL DOCUMENTS FOR ADDITIONAL DEVICES INCLUDED ON THE ROOF. CONTRACTOR
TO COORDINATE LAYOUTS AND MOUNTING REQUIREMENTS
3. ROOF SLOPE: MEMBRANE ROOF ASSEMBLIES TO BE INSTALLED WITH MINIMUM 1/2" INCH PER 1'-0" SLOPE TO
DRAIN/SCUPPER, UNLESS OTHERWISE NOTED.
4. ROOF INVERTS: MEMBRANE ROOF ASSEMBLIES ESTABLISH LOW POINT INVERTS AT ROOF DRAIN AND/OR SCUPPER LOCATIONS WITH MINIMUM THICKNESS OF 1'-2" OF RIGID INSULATION- WHICH MEETS A R60.
5. ROOF CURBS: WHERE SCHEDULED ON THE ROOF PLAN, PROVIDE INSULATED ROOF CURBS EXTENDING A MINIMUM
12 INCHES ABOVE THE ADJACENT ROOF MEMBRANE, UNLESS OTHERWISE NOTED.
6. WALKWAY PADS: INSTALL WALKWAY PADS AT ALL EXPOSED EPDM HORIZONTAL AND VERTICAL SURFACES. REFER
TO SPECIFICATION SECTION 07 53 23.02 00 FOR ADDITIONAL INFORMATION
7. PROVIDE SADDLES AND CRICKETS ON UPHILL SIDE OF ALL ROOF MOUNTED EQUIPMENT AND PENTRATIONS
GREATER THAN 24". CRICKETS TO BE A MIN OF 1/4" PER 1'-0"
ROOF DRAIN AND OVERFLOW ROOF DRAIN WITH
STRAINER
REFER TO DETAIL 5/A-903502E
VTR
REFER TO DETAIL 6/A-903502E
IPID SENSOR- REFER TO SECURITY PLANS AND DETAILS FOR ADDITIONAL INFORMATION
HORIZONTAL LIFELINE ANCHOR, LOCATIONS ARE APPOXIMATE, REFER TO
STRUCTURAL DRAWINGS AND TO DETAIL 7/A-903502E
ROOF HATCH
EXTERIOR MOUNTED LIGHT- REFER TO RCP/ ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
TAPERED INSULATION- REFER TO ROOF ASSEMBLY: TYPE 1
RING SENSOR: MOUNT TO 1/2" DIAMETER RMC- MIN 24" ABOVE
PARAPET WALL WITH (2) GALVANIZED U-STRAP FASTENERS
AC B
A-903502E
SOFFIT PANELS TO ALIGN WITH
PANELS ON EXTERIOR FACE
SOFFIT PANELS TO ALIGN WITH
PANELS ON EXTERIOR FACE
AFF8' - 0" AFF8' - 0"
EXP
MECHANICAL AIR CURTAIN
MECHANICAL AIR CURTAIN
A-903502E
AFF8' - 0"
103106
A-903503E
SIM
A-903503E
SIM
A-903503E
A-903503E
SIM
X'-X" A.F.F.
INSULATED METAL PANEL
GWB
EXPOSED TO
STRUCTURE
2' X 2' ACP AND GRID
CEILING HEIGHT
RECESSED DOWN LIGHT - SEE
ELECTRICAL DRAWINGS BY OTHERS
2 X 4 LIGHT FIXTURE - SEE ELECTRICAL
DRAWINGS BY OTHERS
MECHANICAL DIFFUSERS- SEE
MECHANICAL DRAWINGS BY OTHERS
EXP
1. FIELD VERIFICATION: CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND VERTICAL CONTROL PRIOR TO THE COMMENCEMENT OF WORK.
PROMPTLY NOTIFY THE OWNER’S REPRESENTATIVE OR CONTRACTING OFFICER IN WRITING OF DISCREPANCIES IN NEW AND/OR EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL ABOVE CEILING WORK TO ENSURE CLEARANCES FOR SCHEDULED
CEILING HEIGHTS.
2. DIMENSION GUIDE: ALL DIMENSIONS ARE TAKEN TO/FROM GRID LINE, FACE OF CONCRETE AND MASONRY, AND FACE OF METAL/WOOD STUD PARTITION, UNLESS OTHERWISE NOTED. CLEAR DIMENSIONS WILL BE NOTED WHERE APPLICABLE FROM MATERIAL FINISHES.
3. CEILING HEIGHTS: ALL CEILINGS DESIGNATED ON THIS PLAN SHALL BE 9’-0” ABOVE THE FINISH FLOOR, UNLESS OTHERWISE NOTED ON THE PLAN. ALL CEILING HEIGHTS CORRESPOND TO THE RESPECTIVE FINISH FLOOR ELEVATION/LEVEL.
4. CEILING DEVICES: ALL CEILING LAYOUT PLANS SHOW MOST MAJOR MECHANICAL AND ELECTRICAL DEVICES. SEE MECHANICAL AND ELECTRICAL DOCUMENTS FOR ADDITIONAL M/E DEVICES INCLUDED IN THE CEILING CONFIGURATION. CONTRACTOR TO COORDINATE LAYOUT OF ALL DEVICES. ALL M/E DEVICES SCHEDULED FOR SUSPENDED ACOUSTIC CEILING PANEL (ACP), OR ACOUSTIC CEILING TILES (ACT) TO BE LOCATED IN THE CENTER OF EACH PANEL/TILE. DEVICES SCHEDUELED FOR(GWB) GYPSUM WALL BOARD CEILINGS SHALL BE CENTERED IN
THE SPACE UNLESS OTHERWISE NOTED.
5. PARTITION TYPES: PARTITION TYPES AND RELATED HEIGHTS ARE REFERENCED ON THE SCHEDULE ON SHEET G-903004E.
6. CEILING ACCESS: PROVIDE CEILING ACCESS PANELS, AS SPECIFIED IN SECTION 083100 IN ALL INACCESSIBLE CEILINGS WHERE
EQUIPMENT/DEVICES REQUIRING ACCESS ARE LOCATED. COORDINATE LOCATION WITH EXISTING DESIGN LAYOUT, WITH SIZE AS SPECIFIED.
7. SPRINKLER HEADS: ALL SPRINKLER HEADS SCHEDULED FOR SUSPENDED ACOUSTIC CEILING PANEL (ACP), OR ACOUSTIC CEILING TILES (ACT)
TO BE LOCATED IN THE CENTER OF EACH PANEL/TILE. COORDINATE LOCATIONS WITH FIRE PROTECTION PLANS, MECHANICAL AND
ELECTRICAL DEVICES.
8. LATERAL SUPPORT: PROVIDE LATERAL SUPPORT AND UPLIFT RESTRAINT AT ALL SUSPENDED ACOUSTICAL PANEL/TILE CEILINGS AS REQUIRED BY THE LOCAL JURISDICTION (ASTM). COORDINATE LOCATIONS WITH ABOVE CEILING DEVICES AND RELATED CLEARANCES.
EXTERIOR SOFFITS: ALL EXTERIOR SOFFITS TO COMPLY WITH DESIGN WIND PRESSURES FOR SPECIFIED LOADING REQUIREMENTS. SEE
STRUCTURAL FOR PERFORMANCE REQUIREMENTS.
RCP LEGEND RCP GENERAL NOTES
SMOKE DETECTORSD
1 X 4 LIGHT FIXTURE - SEE ELECTRICAL
DRAWINGS BY OTHERS
EXIT SIGN - SEE ELECTRICAL DRAWINGS
BY OTHERS
OCCUPANCY SENSOR
ST
F
RO
P
ISTE H
A
SS NOI ARL C
A
T
K
ER
IG RE
DE
F
49th
EAT
O LA SA
CE
TNo. AELA-7941
James E. Dougherty
DEPA
R
T M
E N
T O
F D
E F
ENSE
MISSILE
DE
FE
N
SE
AGENCY
D ra w in g
Fi le
N am e:
D w g Sc al e:
Pl ot
S ca le
D at e:
D ra wn
R
ES
ID
EN
T
EN
G
IN
EE
R
PR
IM
E C
O N
TR
AC
TO
R
Su bm itt ed
D es ig ne d:
R ev ie we d:
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
AN
C
H O
R
AG
E, A
LA
SK
A C
O R
PS
O
F
EN
G
IN
EE
R
S
D at e:
ST
AT
E C
IT
Y
C O
N
TR
AC
TO
R
C O
N
TR
AC
T
N O
R ec om m en de d:
Ap pr ov ed
Reference number:
HGFEDCBA
AS
N
O
TE
D
PL
O
TT
ED
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C
LR
9b
.0 2.
NOT FOR CONSTRUCTION
AF
-1
-3
-0
6/ 4/
0:
:0
AM
C :\U se rs
\m lo ge lin
\D oc um en ts \C
LR
_L
R D
R _E
C F-
A- D
M
_C
EN
TR
AL
_m lo ge lin .rv t
RTA A-903102E
R
EF
LE
C
TE
D
C
EI
L I N
G P
LA
N
/R O
O F
P
LA
N
LO
N
G R
AN
G
E D
IS
C
R
IM
IN
AT
I O N
R A D
AR
C
LE
AR
A
FS
,A
LA
SK
A
JE
D
M C
L
TM
W
1K B1
8- R
-0
C O
N
ST
R U
C
TI
O N
P
AC
KA
G
E
- V O
LU
M
E
1/4" = 1'-0"A-903102E
2 ROOF PLAN
0 4' 8'4' 8'
PLAN NORTH
1/4" = 1'-0"A-903102E
1 REFLECTED CEILING PLAN
0 4' 8'4' 8'
PLAN NORTH
Sy m
Ac tio n
D es cr ip tio n
D at e Ap pv d
AM
AM
R
IN
G
S
EN
S O R
.0 6.
TM
SHEET REFERENCE NUMBER IDENTIFICATION
C-900502A
SITE/BUILDING DESIGNATOR
800 - SSPARS (EXISTING)
804 - SPSPARS ECF FACILTIY (UNDER CONSTRUCTION)
100 - SITE
900 - MCF (MISSION CONTROL FACILITY)
901 - LPP (LRDR POWER PLANT)
902 - LES (LRDR EQUIPMENT SHELTER)
903 - ECF (ENTRY CONTROL FACILITY)
904 - FSV (FUEL STORAGE VAULT)
906 - MF (MAINTENANCE FACILITY)
907 - LRDR SUBSTATION
DISCIPLINE WITH SHEET ORDER
(SHEETS IN THE DRAWING PACKAGE SHALL BE IN THE FOLLOWING ORDER)
G - COVER SHEET
G - GENERAL
V - SURVEY/MAPPING
B - GEOTECHNICAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURAL
I - INTERIOR
F - FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
MH - HVAC
MI - BMS
E - ELECTRICAL
EG - GROUNDING/LIGHTNING PROTECTION
EI - PQMS/PCMS
T - TELECOMMUNICATIONS
TY - SECURITY
Z - HEMP
The "-" or second alpha character is removed and replaced with a "D" for all DEMOLITION sheets.Disciplines are always 2 characters (1 alpha + 1 dash)
OR (2 alpha). Examples:
CLR_LRDR_C-XXX502E.dwg CLR_LRDR_M-XXX501E.dwg CLR_LRDR_TDXXX101E.dwg
SHEET TYPE DESIGNATOR
0 - GENERAL (SYMBOLS, LEGENDS, NOTES, ETC)
1 - PLANS (HORIZONTAL VIEWS)
2 - ELEVATIONS (VERTICAL VIEWS)
3 - SECTION (SECTIONAL VIEWS)
4 - LARGE SCALE VIEWS (PLANS, ELEVATIONS, OR
SECTIONS)
5 - DETAILS
6 - DIAGRAMS
7 - SCHEDULES
8 - USER DEFINED
9 - 3D REPRESENTATIONS (ISOMETRICS,
PERSPECTIVES, PHOTOGRAPHS)
SHEET TASK IDENTIFIER
A - SITE/INFRASTRUCTURE
B - MCF
C - LPP
D - LES FOUNDATION
E - SITE SECURITY & ECF
F - LPP SITE AND FUEL STORAGE
G - FINAL SITE WORK & MF
H - SUBSTATION & MISSION POWER
CONSECUTIVE NUMBERS
NUMBERING STARTS WITH "01"
SHEET REFERENCE IDENTIFER REFERENCE
NUMBER SHEET TITLESHT REFERENCE
NUMBER SHEET TITLESHT SHEET TITLESHT REFERENCE
NUMBER
E-100301E ELECTRICAL DUCT BANK CROSS SECTION & SCHEDULE
E-100401E ECF/ MCF SERVICE INTERFACES AND HEAT TRACE
E-100402E ELECTRICAL FIELD DISTRIBUTION BOX PLANS
E-100501E ELECTRICAL MANHOLES- HANDHOLES
E-100503E LIGHTING POLE INSTALLATION DETAILS
EG100101E
EG100501E
SITE PLAN - GROUNDING
TELECOMMUNICATIONS
T-100001E TELECOMMUNICATION LEGEND
T-100101E SITE PLAN - COMMUNICATIONS NORTHWEST
T-100102E
T-100301E TELECOM DUCT BANK CROSS SECTION AND SCHEDULE
T-903101E FLOOR PLAN - COMMUNICATION
T-903201E COMMUNICATIONS ROOM ELEVATIONS
TY100001E SECURITY LEGEND 109
SITE PLAN - SECURITY SOUTHEAST111 TY100102E
TY100401E SECURITY SITE PLAN SECTORS 1-2
TY100402E SECURITY SITE PLAN SECTORS 3-4
TY100403E SECURITY SITE PLAN SECTORS 5-6
TY100404E
TY100405E
TY100406E SECURITY SITE PLAN SECTORS 11-12
TY100407E
TY100408E
TY100501E SECURITY PERIMETER SENSOR INSTALLATION DETAILS
TY100502E
TY100503E SECURITY PERIMETER CCTV CAMERA MOUNTING DETAILS
TY100504E
TY100505E SECURITY DETAILS
TY100601E SECURITY IDS PLAN - OVERALL ONE - LINE DIAGRAM
TY-903101E FLOOR PLAN - SECURITY
TY903111E ROOF PLAN - SECURITY
TY903501E TURNSTILE AND DOORS
TY903502E SECURITY DETAILS
TY903601E SECURITY DIAGRAM- INTRUSION
TY903602E SECURITY DIAGRAM - CCTV
ALASKA DISTRICT U.S. ARMY CORPS OF ENGINEERS
W911KB-18-R-0006
CLR039b 2018.02.14
LONG RANGE DISCRIMINATION RADAR
CLEAR AFS, ALASKA
SCHEDULE OF DRAWINGS
CONSTRUCTION PACKAGE 2 - VOLUME 1 RTA SUBMITTAL
NOT FOR CONSTRUCTION
SITE PLAN - COMMUNICATIONS SOUTHEAST
SECURITY
SECURITY SITE PLAN SECTORS 7-8
SECURITY SITE PLAN SECTORS 9-10
SECURITY SITE PLAN SECTORS 13-14
SECURITY PERIMETER SENSOR INSTALLATION DETAILS
E-100403E
E-100404E
ELECTRICAL HBH DISTRIBUTION PLAN
ELECTRICAL HBH EQUIPMENT DETAILS
E-100701E ELECTRICAL SCHEDULES
EG100601E
GROUNDING DETAILS
T-100601E TELECOM SITE RISER DIAGRAM INTERCONNECTION
DIAGRAM
T-100701E
T-100702E
TELECOM CABLE SCHEDULE MISSION SUPPORT-
RACEWAYS
TELECOM CABLE SCHEDULE MISSION SUPPORT- CABLE
T-903601E DIAGRAMS- COMMUNICATION
SECURITY LARGE SCALE PLAN
SECURITY PERIMETER BURIED SENSOR LINE DETAILS
E-100124E SITE PLAN - POWER EAST
E-100123E SITE PLAN - POWER SOUTH
ED100103E SITE PLAN - TEMPORARY POWER PROVISIONS
E-100111E
E-100113E
E-100114E
E-100121E
SITE PLAN - LIGHTING NORTHWEST
SITE PLAN - LIGHTING SOUTH
SITE PLAN - LIGHTING EAST
SITE PLAN - POWER NORTH
E-100122E SITE PLAN - POWER WEST
E-100702E ELECTRICAL SCHEDULES
E-903101E
E-903111E
FLOOR PLAN - LIGHTING
FLOOR PLAN - POWER
E-903501E DETAILS - LIGHTING CONTRACTORS
E-903502E DETAILS - HEAT TRACE
E-903601E DIAGRAM - POWER ONE-LINE
E-903701E PANEL SCHEDULES
PANEL SCHEDULES
GROUNDING RISER DIAGRAM
T-900401E COMMS ENLARGED PLAN VIEW
E-100004E ABBREVIATIONS
TY100103E SITE PLAN - SECURITY CCTV NORTHWEST
TY100104E SITE PLAN - SECURITY CCTV SOUTHEAST
TY100506E SECURITY DETAILS
TY100101E SITE PLAN - SECURITY NORTHWEST
TY100701E CABLE AND RACEWAY SCHEDULES
E-100003E ABBREVIATIONS 154
E-100002E EQUIPMENT & SHEET DESIGNATION IDENTIFICATION
ELECTRICAL
ELECTRICAL LEGEND
CONTROL POINTS
E-100001E
M-903802E
E-100504E DETAILS
E-100505E DETAILS
E-100506E DETAILS
E-903702E
EG903112E FLOOR PLAN - GROUNDING
TY100507E SECURITY DETAILS
TY903603E SECURITY DIAGRAM - TAMPER
TY100702E CABLE AND RACEWAY SCHEDULES
TY804501E DETAILS- CABINET ELEVATIONS
TY804101E SECURITY PLAN- ECF
SHEDULE OF OPERATIONSM-903801E
M-903601E SYSTEMS DIAGRAMS
M-903701E MECHANICAL SCHEDULES
TY100508E
TY100509E
CAMERA POLE TYPE C
SECURITY PLOE BASE DETAIL
M-903401E FLOOR PLAN - MECHANICAL ROOM
M-903501E DETAILS - HVAC
2 AM #2 SHEET TITLE CHANGE 2018.06.04 TM
| Sheets |
| A-903102E - REFLECTED CEILING PLAN/ROOF PLAN |
| 18_0604 SHEET INDEX.pdf |
| Sheets |
| G-000003 - INDEX PART 2 |
File details come from the government source that posted it.