EIE326_RFP_TAB4_drawings_2013-12-24.pdf

PDF 13 MB Posted

Attached to
Design/Construct 168 Person Dormitory (EIE326), Eielson AFB, Alaska
Solicitation number
W911KB-14-R-0017
Issued by

About this file

Drawings

View the file

Other files

File Type Posted
AM_7.pdf PDF
Attachement_10_Energy Sustainability_Record_Card.xlsx XLSX spreadsheet
EIE326-01_19_10_00_29-2_7_AM_6.pdf PDF
EIE326-RoomCriteria_2014-05-05_AM_6.pdf PDF
EIE326_Proosal_Schedule__AM_6.pdf PDF
EIE326_RFP_TOC_2014-05-06_AM_6.pdf PDF
A_3_6_2_J A14-38_Delta_Controls_Redacted.pdf PDF
ProjNet_Bidder_Inquiry_Report.pdf PDF
01_19_10.00_29_2.4.14-Dryers.pdf PDF
A_3_6_2_J A_14-37_Cooper_Redacted.pdf PDF
AM_6.pdf PDF
A_3_6_2_J A_14-35_Knox_Redacted.pdf PDF
A_3_6_2_J A_14-34_BasisV_card_access_Redacted.pdf PDF
A_3_6_2_J A_14-36_Monaco_Redacted.pdf PDF
01_57_20.00_10_Attachment_N_2014-05-06_AM_6.pdf PDF
A_3_6_2_J A_14-33_Best_locks_Redacted.pdf PDF
EIE326-01_19_10_00_29-2_2_AM_5_Pages.pdf PDF
EIE326-RoomCriteria_AM_5.pdf PDF
EIE326-L101_Half_AM_5.pdf PDF
EIE326-01_19_10_00_29-2_8_AM_5_Pages.pdf PDF
AM_5.pdf PDF
APPNDX05-USGBC-CHP-Guidance-for-FTW-Project-AM_5.pdf PDF
EIE326-01_19_10_00_29-2_6.pdf PDF
EIE326-02_61_13_AM_5.pdf PDF
EIE326-01_19_10_00_29-2_4_AM_5_Pages.pdf PDF
EIE326-01_19_10_00_29-2_10_AM_5.pdf PDF
EIE326_D1_00_Half_AM_5.pdf PDF
EIE326-L102_Half_AM_5.pdf PDF
EIE326-01_19_10_00_29-2_9_AM_5_Pages.pdf PDF
A.2.11.3.1_SolicAmend_EIE326-AM4.pdf PDF
A.2.11.3.1_SolicAmend_EIE326-AM3.pdf PDF
EIE326_RFP_TAB2_2014-03-24.pdf PDF
EIE326_RFP_TAB3_2014-03-24.pdf PDF
EIE326_RFP_TAB1_2014-03-19.pdf PDF
RevisedSECTION_00_22_20.pdf PDF
Amendment__2.pdf PDF
AM_1.pdf PDF
Module-Aerial.jpg JPG image
EIE326_RFP.pdf PDF
EIE326-RoomCriteria.pdf PDF
Module-Aerial-3.jpg JPG image
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J4PMMJC9

Typewritten Text xxxxxx

J4PMMJC9

Typewritten Text

J4PMMJC9

Typewritten Text

J4PMMJC9

Typewritten Text

J4PMMJC9

Typewritten Text xxxxxxx

J4PMMJC9

Typewritten Text

J4PMMJC9

Typewritten Text

J4PMMJC9

Typewritten Text xxxxx

J4PMMJC9

Typewritten Text

J4PMMJC9

Typewritten Text x

J4PMMJC9

Typewritten Text xxxxxxxxxxxxxxxxx

J4PMMJC9

Typewritten Text

J4PMMJC9

Typewritten Text xxxxxxxxxxxxxxxxx

J4PMMJC9

Typewritten Text

WABASH AVENUE

N O R

TH

S

TR

E E T

PROPOSED STREET

TREE PLANTING

EXISTING STREET

TREES TO REMAIN

25M ATFP OFFSET

10M ATFP OFFSET RETAINING

WALL

MAIN ENTRY

LANDSCAPE

EXISTING BLDG

(TO BE DEMOLISHED)

EXISTING SIDEWALK

(TO BE REMAIN)

EXISTING

TREES

TO REMAIN

EXISTING UTILIDOR

(TYP.)

GRAVEL ACCENT

BED (TYP. @

DRIPLINE)

CONCRETE

SIDEWALK

(TYP.)

EXISTING

PARKING

BLDG 2208

BLDG 2210

BLDG 2204

EXISTING

PARKING

PROPOSED

DORMITORY

88 TOTAL SPACES

EXISTING

TREES

TO REMAIN

COVERED

BIKE RACKS PLAZA AREA

SITE

LIGHITNG PROPOSED

TREES

SITE

LIGHITNG

DUMPSTER WITH

ENCLOSURE KOBUK

OF ENGINEERS

US ARMY CORPS

ALASKA DISTRICT

Reference number:

Sheet of

HGFEDCBA

E

IE

LS

O N

A F B A

LA

S K A

E

IE

D O R M A

TO

R Y

(1 P N

A ct io n

Sy m

D a te

D es cr ip ti o n

A p p vd

IN

V.

N O

PN

FT

R2

D ra w in g

F il e

D w g

S c a le

P lo t S ca le

D a te

D ra w n

S u b m it te d

D e si g n e d

R e vi e w e d

C h ie f, B ra n c h

C h ie f, S ec ti o n

A S

N O

TE

D

:1

W 1K B -

D 0 0

R E S

ID

E N T E N G

IN

E E R

P R

IM

E

C O N

TR

A C

TO

R

D a te

C O N

TR

A C T N O

R e co m m en d ed

A p p ro ve d

W K B D

JU

LY

J:

\A

0p ro j\A

.0 6\

R ev it\ A

_E

IE

6_ si te .r vt 7/

/2

:0

4:

A M

L101

P

LA

N T

IN

G

P

LA

N

B A

S E

P

LA

N T

IN

G

P

LA

N

B A

S E

E R L

C h e c ke r

E R L

1" = 30'-0"1 PLANTING PLAN - BASE

UP

MULTI-PURPOSE /

COMMONS

DORM

MANAGEMENT

MAIN

ENTRY

MAIN

ELEC.

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

MAIN

COMM.

JAN. /

HSKP'NG

JAN. /

HSKP'NG

MAIN

MECH.

BULK STORAGE LAUNDRY

PUBLIC

TOILET

ELEV.

MCHN.

ELEV.

STORAGE

VENDING

COMM.ELEC.

ELEC.

STAIR

C O

R R

I D

O R

CORRIDOR

STAIR

LOBBY

STAIR

3/32" = 1'-0"

FIRST FLOOR DIAGRAM

UP DN

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

JAN. /

HSKP'NG

JAN. /

HSKP'NG

LAUNDRY

ELEV.

COMM.ELEC.

ELEC.

STAIR

C O

R R

I D

O R

CORRIDOR

STAIR

STAIR

COMM.

3/32" = 1'-0"

SECOND FLOOR DIAGRAM

SCALE: 3/32" = 1'-0"

5'-4" 10'-8"0 21'-4"

DN

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

DORM-4-AIRMEN

MODULE

COMM.

JAN. /

HSKP'NG

JAN. /

HSKP'NG

LAUNDRY

ELEV.

COMM.ELEC.

ELEC.

STAIR

C O

R R

I D

O R

CORRIDOR

STAIR

STAIR

3/32" = 1'-0"

THIRD FLOOR DIAGRAM

SCALE: 3/32" = 1'-0"

5'-4" 10'-8"0 21'-4"

File details come from the government source that posted it. Updated .