EIE326-01_19_10_00_29-2_9_AM_5_Pages.pdf

PDF 12 KB Posted

Attached to
Design/Construct 168 Person Dormitory (EIE326), Eielson AFB, Alaska
Solicitation number
W911KB-14-R-0017
Issued by

About this file

Section 00 19 10.00 29 Para 2.9.8

View the file

Other files

File Type Posted
AM_7.pdf PDF
Attachement_10_Energy Sustainability_Record_Card.xlsx XLSX spreadsheet
EIE326-01_19_10_00_29-2_7_AM_6.pdf PDF
EIE326-RoomCriteria_2014-05-05_AM_6.pdf PDF
EIE326_Proosal_Schedule__AM_6.pdf PDF
EIE326_RFP_TOC_2014-05-06_AM_6.pdf PDF
A_3_6_2_J A14-38_Delta_Controls_Redacted.pdf PDF
ProjNet_Bidder_Inquiry_Report.pdf PDF
01_19_10.00_29_2.4.14-Dryers.pdf PDF
A_3_6_2_J A_14-37_Cooper_Redacted.pdf PDF
AM_6.pdf PDF
A_3_6_2_J A_14-35_Knox_Redacted.pdf PDF
A_3_6_2_J A_14-34_BasisV_card_access_Redacted.pdf PDF
A_3_6_2_J A_14-36_Monaco_Redacted.pdf PDF
01_57_20.00_10_Attachment_N_2014-05-06_AM_6.pdf PDF
A_3_6_2_J A_14-33_Best_locks_Redacted.pdf PDF
EIE326-01_19_10_00_29-2_2_AM_5_Pages.pdf PDF
EIE326-RoomCriteria_AM_5.pdf PDF
EIE326-L101_Half_AM_5.pdf PDF
EIE326-01_19_10_00_29-2_8_AM_5_Pages.pdf PDF
AM_5.pdf PDF
APPNDX05-USGBC-CHP-Guidance-for-FTW-Project-AM_5.pdf PDF
EIE326-01_19_10_00_29-2_6.pdf PDF
EIE326-02_61_13_AM_5.pdf PDF
EIE326-01_19_10_00_29-2_4_AM_5_Pages.pdf PDF
EIE326-01_19_10_00_29-2_10_AM_5.pdf PDF
EIE326_D1_00_Half_AM_5.pdf PDF
EIE326-L102_Half_AM_5.pdf PDF
A.2.11.3.1_SolicAmend_EIE326-AM4.pdf PDF
A.2.11.3.1_SolicAmend_EIE326-AM3.pdf PDF
EIE326_RFP_TAB2_2014-03-24.pdf PDF
EIE326_RFP_TAB3_2014-03-24.pdf PDF
EIE326_RFP_TAB1_2014-03-19.pdf PDF
RevisedSECTION_00_22_20.pdf PDF
Amendment__2.pdf PDF
AM_1.pdf PDF
Module-Aerial.jpg JPG image
EIE326_RFP.pdf PDF
EIE326-RoomCriteria.pdf PDF
EIE326_RFP_TAB4_drawings_2013-12-24.pdf PDF
Module-Aerial-3.jpg JPG image
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DORMITORY, 168 PN EIELSON AFB, AK W911KB-17-R-0017

SECTION 01 19 10.00 29 EIE 326

2.9.7 Option 8 – AM#4…

Requirement deleted in its entirety.

…..AM#4

2.9.8 Option 9–BBQ Shelter

A. Scope and Objectives – Provide a 200sq.ft. (10’ x 20’) BBQ Shelter for resident use.

B. Site Planning and Landscape - The BBQ shelter shall be located adjacent to the patio and in close proximity to the Multi-purpose room of the facility. The shelter shall be connected to the new dormitory with a sidewalk.

1. The shelter shall be located to conveniently service the new dormitory.

2. The shelter shall have sidewalks that lead to the multi-purpose room and connect to existing sidewalks.

3. Built-in barbeque grills shall be located immediately adjacent to the covered BBQ shelter and permanently installed. The grill shall be placed on a 6 foot x foot concrete slab and have a minimum cooking surface area of 700 square inches (20”x35”). The barbeque grill shall have an area to place food prior to cooking and a separate area for placing food after cooking. The grill shall be weather proof and have a lockable lid.

C. Civil - BBQ Shelter: The civil scope of work for this option includes providing a concrete foundation and associated structural section under the foundation as required to support the BBQ Shelter structure. Additional pedestrian pathways may be required for access to the BBQ Shelter.

D. Structural - Provide complete structural system, calculations, and material submittals for approval prior to construction. The structure shall be compatible with the architectural design and be an acceptable building system as defined in section 2.5.

E. Mechanical – Provide a built in barbeque grill AM#5… that utilizes charcoal as a fuel source.

…AM#5

F. Electrical – Provide vandal-resistant, wet location listed light fixture with automatic lighting control. Light fixture type shall match site lighting. Provide GFCI convenience receptacles with while-in-use weatherproof enclosures.

2.9.9 Option 10 – Reconfigure Kobuk Loop Traffic flow

A. Scope and Objectives - Reconfigure Kobuk Loop Traffic flow: The existing traffic flow at the west side of the project site utilizes what it called Kobuk Loop, which is the east vehicular isle of the west parking lot. This option would redirect traffic to utilize with west traffic isle of the west parking lot. This would be achieved by removing an area of existing pavement and introducing a landscape island at the location.

B. Demolition - This option includes the removal of existing AC pavement as required to reconfigure Kobuk Loop traffic flow and install new landscaping. See Site Planning and Landscape for additional requirements for this option.

C. Site Planning and Landscape - Reconfigure Kobuk Loop to direct vehicular traffic into the southernmost drive lane of the existing parking lot. Provide a landscape island and allow only one ingress/egress point from the existing parking lot onto North Street.