ATT_A_Bid_Schedule.xls

XLS spreadsheet 455 KB Posted

Attached to
Open End Electrical Requirements Contract Federal contract opportunity
Solicitation number
W91151-16-B-0021
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Hood

About this file

Exhibit A - Bid Schedules

View the file

Other files for this federal contract opportunity

Other files attached to Open End Electrical Requirements Contract, newest first.
File Type Posted
Tech_Exhibit_A_-_Bid_Schedule_REVISED_25AUG2016.xls XLS spreadsheet
W91151-16-B-00210-00002_Bid_Sheets_Revised.pdf PDF
ATT_V_-_High_Mast_Poles_and_Foundations.docx DOCX document
Technical_Exhibit_B2_-_Specifications_REVISED.pdf PDF
Technical_Exhibit_B1_-_Division_1_Specifications_REVISED.pdf PDF
W91151-16-B-00210-00001_RFI.pdf PDF
ATT_A_Bid_Schedule_REVISED.xls XLS spreadsheet
ATT_P_-_Static_Ground_Details.pdf PDF
ATT_F_-_FM_10-67-1_-_Concepts_and_Equipment_of_Petroleum_Operations.pdf PDF
ATT_R_-_FH_REG_420-9_-_Energy_Conservation_Program.pdf PDF
ATT_Q_-_Transformer_Concrete_Pad_Detail.pdf PDF
ATT_S_-_LED_FIXTURE_DETAIL.pdf PDF
ATT_D_-_Section_16520e_-_Exterior_Light_Fixtures_Schedule.pdf PDF
ATT_U_-_SPECIAL_PROVISIONS.pdf PDF
Technical_Exhibit_B_-_Division_1_Specifications.pdf PDF
ATT_J_-_Trench_and_Grounding_Details.pdf PDF
ATT_T__-_Electrical_GIS_SOP.pdf PDF
W91151-16-B-0021.pdf PDF
ATT_H_-_AR_190-11_-_Physical_Security_of_Arms _Ammunition _and_Explosives.pdf PDF
ATT_L_-_In-Line_Electrical_Primary_Riser_Detail.pdf PDF
ATT_B_-_Specifications.pdf PDF
Technical_Exhibit_B3_-_Electric_Meter_Specifications.pdf PDF
ATT_G_-_PAM_385-64_-_Ammunition_and_Explosives_Safety_Standards.pdf PDF
ATT_K_-_Handhole_Details.pdf PDF
ATT_C_-_Section_16510e_-_Interior_Light_Fixtures_Schedule.pdf PDF
ATT_M_-_In-Line_Electrical_Primary_Riser_at_90_Degrees_to_Line_Detail.pdf PDF
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BASE PERFORMANCE YEAR

ALL LINE ITEMS SHALL BE BID BASED ON SPECIFICATIONS AND ALL ATTACHEMENTS AND ENSURE ARE IN ACCORDANCE WITH NFPA 70 AND NESC HANDBOOK . ALL ITEMS INSTALLED IDENTIFIED IN ATT R SHALL HAVE DATA WORKSHEET TURN IN WITH THE ASBUILTS.
Item NumberSubDescriptionEst QtyUnitUnit priceTOTAL
0001Install Wooden pole in existing or new overhead power line of single or double circuit, 1 PH or 3 PH 4 wire primary or secondary. To include pole grounding conductor and wood pole ground molding. (Not to include cross-arms or hardware).
0135' Class 5 pole4EA$0.00$0.00
0235' Class 2 pole2EA$0.00$0.00
0340' Class 4 pole3EA$0.00$0.00
0440' Class 2 pole3EA$0.00$0.00
0545' Class 4 pole3EA$0.00$0.00
0645' Class 2 pole4EA$0.00$0.00
0750' Class 4 pole6EA$0.00$0.00
0850' Class 2 pole5EA$0.00$0.00
0955' Class 4 pole6EA$0.00$0.00
1055' Class 2 pole5EA$0.00$0.00
1160' Class 2 pole10EA$0.00$0.00
1265' Class 2 pole10EA$0.00$0.00
1375' Class 2 pole6EA$0.00$0.00
14Remove existing pole thru 60 foot tall to include backfill of hole and compaction to 95 percent if required5EA$0.00$0.00
15Remove existing pole thru 80 foot tall. To include backfill of hole and compaction to 95 percent if required7EA$0.00$0.00
16Straighten existing pole thru 60 foot5EA$0.00$0.00
17Straighten existing pole thru 80 foot2EA$0.00$0.00
18Transfer existing down guy, sidewalk guy or overhead guy to new structure5EA$0.00$0.00
19Transfer existing cross-arm to new structure15EA$0.00$0.00
20Transfer pins, insulators and conductors to new structure. (Per conductor, size thru #4/0)10EA$0.00$0.00
21Transfer pins, insulators and conductors to new structure. (Per conductor, size thru #47720EA$0.00$0.00
22Transfer pins, insulators and conductors to new structure. (Per conductor, size thru #795).20EA$0.00$0.00
23Transfer static neutral pin and insulator to new structure.30EA$0.00$0.00
24Transfer static neutral and suspension insulator to new structure. (At dead end situations).10EA$0.00$0.00
25Transfer spool insulator and neutral conductor to new structure. (Conductor size thru #4/0)10EA$0.00$0.00
26Transfer dead end conductor to new structure, complete. To include dead end shoes, suspension insulators, jumper conductors, and related hardware (Per conductor size thru #4/0).15EA$0.00$0.00
27Transfer dead end conductor to new structure, complete. To include dead end shoes, suspension insulators, jumper conductors, and related hardware (Per conductor size thru #477).15EA$0.00$0.00
28Transfer dead end conductor to new structure, complete. To include dead end shoes, suspension insulators, jumper conductors, and related hardware (Per conductor size thru #795).20EA$0.00$0.00
29Transfer communication line or CATV cable to new structure. To include attachments. (Per cable).20EA$0.00$0.00
30Transfer street light conductors and insulators to new structure. (Up to 2 conductors and insulators).20EA$0.00$0.00
31Remove communication or CATV or Steel messenger from pole and disposal200LF$0.00$0.00
32Transfer street light, sports light or flood light fixture to new structure. To include arm, brackets, all hardware and connections10EA$0.00$0.00
33Transfer single transformer with primary fuse cutout and lightning arrester, size thru 167 KVA and all related hardware from pole or DPW yard to new structure.10EA$0.00$0.00
34Transfer 3 PH transformer bank with primary fuse cutout and lightning arrester, size thru 300 KVA and all related hardware from pole or DPW yard to new structure.10EA$0.00$0.00
35Transfer fuse cutout or lightning arrestor from pole or DPW yard to new structure10EA$0.00$0.00
36Transfer Secondary service drops of 1PH or 3 PH, size thru #2, to new structure.10EA$0.00$0.00
37Transfer Secondary service drops, 1PH or 3 PH size thru #4/0, to new structure5EA$0.00$0.00
38Transfer open secondary and rack, up to 4 conductors, to new structure.5EA$0.00$0.00
39Transfer pole mounted service riser, 1PH or 3 PH. To include weather head, disconnect switch and connections (Up to 200A).5EA$0.00$0.00
40Transfer pole mounted service riser, 1PH or 3 PH. To include weather head, disconnect switch and connections (Up to 400A).5EA$0.00$0.00
41Transfer pole mounted service riser, 1PH or 3 PH. To include weather head, disconnect switch and connections (Up to 800A).5EA$0.00$0.00
42Transfer exterior rack mounted weatherproof service equipment from existing location to new location, 1PH or 3 PH. To include mounting hardware, mounting service equipment to new rack, connections to new conduits and conductors. Not to include new switch rack. (Up to 200A).5EA$0.00$0.00
43Transfer exterior rack mounted weatherproof service equipment from existing location to new location, 1PH or 3 PH. To include mounting hardware, mounting service equipment to new rack, connections to new conduits and conductors. Not to include new switch rack. (Up to 400A).2EA$0.00$0.00
44Transfer exterior rack mounted weatherproof service equipment from existing location to new location, 1PH or 3 PH. To include mounting hardware, mounting service equipment to new rack, connections to new conduits and conductors. Not to include new switch rack. (Up to 800A).3EA$0.00$0.00
45Transfer existing steel ball field type lighting pole from existing location to new location, complete. To include complete disassembly, transportation and reassembly at new location of up to a 75 foot tall steel pole, all brackets, arms, cat walks, up to 12 each sports light fixtures, ballasts, pole mounted panel board or controls, conductors, all connections to new power source and lighting system. Not to include new concrete pier or new underground lighting circuits1EA$0.00$0.00
46Transfer underground communication line or CATV cable in conduit to new pole2EA$0.00$0.00
47Transfer underground communication line or CATV cable to new pole with no conduit.2EA$0.00$0.00
0002Install 1,200 amp, (VCB) vacuum circuit breaker, 7,200/12,470 volt with remote or self contained controls, VCB shall match existing vacuum circuit breakers used on Ft Hood. To include conductors and connections.1EA$0.00$0.00
0003Remove existing up to 1,200 amp, (VCB) vacuum circuit breaker or (OCB) oil circuit breaker, 7,200/12,470 volt. To include disconnection of existing conductors and control wiring.1EA$0.00$0.00
0004Install new 600A rated, non fused, gang-operated air switch with load-break expulsion type interrupters onto existing double dead-end configuration pole. Complete with 3 EA, 9 KV distribution class surge arresters on EA side of switch (mounted to under side of switch equipment mounting arm) and a separate grounding system, (using #4 BSD CU, and 3/4"x 8' copper clad steel ground rod(s) for not more than 25 ohms ground resistance), bonded above grade to switch operating handle and below grade to existing pole grounding system1EA$0.00$0.00
0005Install new 900A rated, non fused, gang-operated air switch with load-break expulsion type interrupters onto existing double dead-end configuration pole. Complete with 3 EA, 9 KV distribution class surge arresters on EA side of switch (mounted to under side of switch equipment mounting arm) and a separate grounding system, (using #4 BSD CU, and 3/4"x 8' copper clad steel ground rod(s) for not more than 25 ohms ground resistance), bonded above grade to switch operating handle and below grade to existing pole grounding system2EA$0.00$0.00
0006Convert "In-Line" to double dead-end pole configuration and dead-end conductors to new cross arms, complete. Include dead-end shoes, suspension insulators, jumper conductors, related hardware, and re-sag conductors. Conductor size through #2/01EA$0.00$0.00
0007Convert "In-Line" to double dead-end pole configuration and dead-end conductors to new cross arms, complete. Include dead-end shoes, suspension insulators, jumper conductors, related hardware, and re-sag conductors. Conductor size through #795 KCM1EA$0.00$0.00
0008Replace existing gang operated air switch with new 600A rated, non-fused, gang-operated air switch with load-break expulsion type interrupters Complete with 3 EA, 9 KV, distribution class surge arresters on EA side of switch (mounted to under side of switch equipment mounting arm), and a separate grounding system (new),(using #4 BSD CU, and 3/4" x 8' copper clad steel ground rod for not more than 25 ohms ground resistance), bonded above grade to switch operating handle and below grade to existing pole grounding system.1EA$0.00$0.00
0009Install new Wooden cross-arm complete (including all hardware and metal braces), with installation or replacement on existing or new structure (Not to include pins, insulators or attachment of conductors).$0.00
013-1/2” x 4-1/2” x 8'25EA$0.00$0.00
024” x 6” x 8'25EA$0.00$0.00
034” x 6” x 10'15EA$0.00$0.00
04Remove existing cross-arm75EA$0.00$0.00
0010Install new down guy and 8-way expanding anchor, complete. To include guy guard and grounding connections.$0.00
01To 12,000 pounds breaking strength5EA$0.00$0.00
02To 30,000 pounds breaking strength5EA$0.00$0.00
03Cost adjustment to install all required hardware for sidewalk down guy5EA$0.00$0.00
04Cost adjustment to install all required hardware for overhead guy500EA$0.00$0.00
05Tighten existing pole guy wire5EA$0.00$0.00
06Remove existing pole guy wire and anchor5EA$0.00$0.00
07Remove existing pole guy anchor5EA$0.00$0.00
0011Install new primary pin and insulator, on existing energized primary power line To include transfer of conductors. (As replacement or new installation).$0.00
01Thru size #4/050EA$0.00$0.00
02Thru size #477 KCM25EA$0.00$0.00
03Thru size #795 KCM25EA$0.00$0.00
0012Install new primary double suspension insulators, on existing energized primary power line. To include transfer of conductors. (As replacement or new installation)$0.00
01Thru size #4/025EA$0.00$0.00
02Thru size #477 KCM10EA$0.00$0.00
03Thru size #795 KCM10EA$0.00$0.00
0013Install new spool insulator clevis and thru bolt, on existing energized power line To include transfer of conductors and connections thru size #4/0 (As replacement or new installation50EA$0.00$0.00
0014Install new messenger hanger and thru bolt on communication or CATV cable. To include transfer of cables. (As replacement or new installation).50EA$0.00$0.00
0015Install new pole grounding conductor on new or existing pole. To include wood molding$0.00
01#6 CU100FT$0.00$0.00
02#4 CU200FT$0.00$0.00
0016Repair pole ground by reconnecting ground conductor with #6 bare soft drawn copper. To include wood molding (Not to exceed 20').45FT$0.00$0.00
0017Install new Hard Drawn Copper (HDC) aerial primary conductors. Splicing only at structures, Per conductor.$0.00
01#6 (HDC).2500FT$0.00$0.00
02#4 (HDC).2500FT$0.00$0.00
0018Install new Aluminum Conductor Steel Reinforced (ACSR) aerial primary conductors. Splicing only at structures, Per conductor$0.00
01#4 (ACSR).2500FT$0.00$0.00
02#2 (ACSR).2500FT$0.00$0.00
03#1/0 (ACSR).2500FT$0.00$0.00
04#2/0 (ACSR)2500FT$0.00$0.00
05#4/0 (ACSR).2500FT$0.00$0.00
06#477(ACSR).5000FT$0.00$0.00
07#795(ACSR)5000FT$0.00$0.00
0019Remove existing aerial primary or secondary conductors, HDC, Stranded CU or ACSR, To include removal of insulators if required$0.00
01#6 thru #4/02500FT$0.00$0.00
02#250 thru #4771000FT$0.00$0.00
03Thru #7951000FT$0.00$0.00
0020Install new Primary Jumper conductors$0.00
01Size thru #4/0 (ACSR).50FT$0.00$0.00
02Size thru #477 (ACSR).50FT$0.00$0.00
03Size thru #795 (ACSR).50FT$0.00$0.00
0021Remove bollards, to include foundation. Backfill hole and compact to 95 percent if required.10EA$0.00$0.00
0022Remove Tx/Rx distribution pedestal, to include hardware, conductor connections, cutting and abandoning conductors a minimum of 6" below finished grade. Backfill hole and compact to 95 percent if required.5EA$0.00$0.00
0023Install new 1 or 3 phase, oil filled, pad mounted transformer, 7200/12,470V primary, secondary voltage as required, copper windings, load breaker inserts, current limiting fuses, radial or loop feed, load break oil switch and 2-2.5 percent taps above and below rated voltage, complete. To include load break elbows and connections.$0.00
01Install new pad mounted transformer thru 75 KVA2EA$0.00$0.00
02Install new pad mounted transformer thru 167 KVA2EA$0.00$0.00
03Install new pad mounted transformer thru 225 KVA2EA$0.00$0.00
04Install new pad mounted transformer thru 300 KVA2EA$0.00$0.00
05Install new pad mounted transformer thru 500 KVA2EA$0.00$0.00
06Install new pad mounted transformer thru 750 KVA2EA$0.00$0.00
07Install new pad mounted transformer thru 1000 KVA2EA$0.00$0.00
08Cost adjustment to provide steel reinforced concrete pad for up to 167 KVA transformer2EA$0.00$0.00
09Cost adjustment to provide steel reinforced concrete pad for up to 300 KVA transformer2EA$0.00$0.00
10Cost adjustment to provide steel reinforced concrete pad for up to 500 KVA transformer2EA$0.00$0.00
11Cost adjustment to provide steel reinforced concrete pad for up to 1000 KVA transformer2EA$0.00$0.00
12Remove existing pad mounted transformer, thru 167 KVA.2EA$0.00$0.00
13Remove existing pad mounted transformer, thru 300 KVA2EA$0.00$0.00
14Remove existing pad mounted transformer, thru 500 KVA2EA$0.00$0.00
15Remove existing pad mounted transformer, thru 1000 KVA2EA$0.00$0.00
16Cost adjustment to provide 8 inch concrete Filled, primed and painted steel bollard. Bollard shall be concrete encased a minimum of 48 inches deep x 24 inches wide with a minimum of 48 inches extending above grade2EA$0.00$0.00
0024Install rebuilt 1 or 3 phase, oil filled, pad mounted transformer, 7200/12,470V primary, secondary voltage as required, copper windings, load breaker inserts, current limiting fuses, radial or loop feed, load break oil switch and 2-2.5 percent taps above and below rated voltage, complete. To include load break elbows and connections

Note: Section 26 12 19.10 paragraph 2.2.4 Corrosion Protection shall not apply to rebuilt pad mount transforms. Following statement shall be applied to following line items

Corrosion Protection:

Entire transformer assembly, including tank and radiator, base, enclosure and metering enclosure shall be fabricated of mild steel. Form enclosure of mild steel sheets. Paint entire transformer assembly Munsell 7GY3.29/1.5 green. Paint coating system shall comply with IEEE C57.12.28. The Munsell color notation is specified in ASTM D 1535.$0.00
01Install rebuilt pad mounted transformer thru 75 KVA2EA$0.00$0.00
02Install rebuilt pad mounted transformer thru 167 KVA2EA$0.00$0.00
03Install rebuilt pad mounted transformer thru 225 KVA2EA$0.00$0.00
04Install rebuilt pad mounted transformer thru 300 KVA2EA$0.00$0.00
05Install rebuilt pad mounted transformer thru 500 KVA2EA$0.00$0.00
06Install rebuilt pad mounted transformer thru 750 KVA2EA$0.00$0.00
07Install rebuilt pad mounted transformer thru 1000 KVA2EA$0.00$0.00
0025Transfer existing 1 or 3 phase, oil filled or dry type, pad mounted transformer from existing location or DPW yard to new location. To include setting existing transformer on concrete pad at new location and connections to new or existing primary and secondary conductors$0.00
01Transfer existing pad mounted transformer thru 75 KVA2EA$0.00$0.00
02Transfer existing pad mounted transformer thru 300 KVA2EA$0.00$0.00
03Transfer existing pad mounted transformer thru 500 KVA2EA$0.00$0.00
04Transfer existing pad mounted transformer thru 1000 KVA2EA$0.00$0.00
0026Install new 1 phase underground primary cable, 15 KV with concentric neutral in a minimum of new 2.5 inch duct. To include excavation 48 inches below finished grade, PVC conduit on plastic chairs below grade in concrete encasement, long sweep galvanized rigid conduit 90 degree bends, galvanized rigid conduit risers, backfill, all conductors, stirrups, hot taps, fused cutouts, 10KV lightning arrestors, terminators, load break elbows, connections and restoration of surface area to match original conditions, to include solid sod in turfed areas and hydro mulch or grass seed as specified in all other areas$0.00
01Install new 1 phase, 15 KV cable with concentric neutral, up to #1 CU500FT$0.00$0.00
02Install new 1 phase, 15 KV cable with concentric neutral, up to #2/0 CU1500FT$0.00$0.00
03Install new 1 phase, 15 KV cable with concentric neutral, up to #4/0 CU500FT$0.00$0.00
0027Install new 3 phase underground primary cables, 15 KV with concentric neutral in a minimum of new 4 inch duct. To include excavation 48 inches below finished grade, PVC conduit on plastic chairs below grade in concrete encasement, long sweep galvanized rigid conduit 90 degree bends, galvanized rigid conduit risers, backfill, all conductors, stirrups, hot taps, fused cutouts, 10KV lightning arrestors, terminators, load break elbows, connections and restoration of surface area to match original conditions, to include solid sod in turfed areas and hydro mulch or grass seed as specified in all other areas.$0.00
01Install new 3 phase, 15 KV cables with concentric neutral, up to #1 CU500FT$0.00$0.00
02Install new 3 phase, 15 KV cables with concentric neutral, up to #3/0 CU500FT$0.00$0.00
0028Replace existing 15 KV CU underground primary cable, and neutral in existing duct. (per conductor).$0.00
01Replace #2, 15 KV with concentric neutral2000FT$0.00$0.00
02Replace #2, 15 KV and #2 600V neutral.200FT$0.00$0.00
03Replace #1, 15 KV with concentric neutral1000FT$0.00$0.00
04Replace #1, 15 KV and #1 600V neutral1000FT$0.00$0.00
05Replace #6 THWN CU, 600V Grounding conductor.1000FT$0.00$0.00
06Replace #4 THWN CU, 600V Grounding conductor1000FT$0.00$0.00
07Replace #2 THWN CU, 600V Grounding conductor1000FT$0.00$0.00
08Replace #1 THWN CU, 600V Grounding conductor.1000FT$0.00$0.00
0029Replace or install terminator connection on existing energized primary power line10EA$0.00$0.00
0030Replace or install terminator connection on existing energized primary power line at substation (1000 KCMIL)5EA$0.00$0.00
0031Replace or install load break elbow connection on existing energized primary power line at pad mounted transformer.10EA$0.00$0.00
0032Replace or install splice on existing aerial or underground primary or secondary. Conductor size thru #4/0.$0.00
01Underground Primary4EA$0.00$0.00
02Underground Secondary4EA$0.00$0.00
03Overhead Primary4EA$0.00$0.00
04Overhead Secondary4EA$0.00$0.00
0033Replace or install splice on existing aerial or underground primary or secondary. Conductor size thru #795 KCM.$0.00
01Underground Primary5EA$0.00$0.00
02Underground Secondary5EA$0.00$0.00
03Overhead Primary5EA$0.00$0.00
04Overhead Secondary5EA$0.00$0.00
0034Replace or install hot tap and stirrup connectors on existing energized primary power line.$0.00
01Size thru #1/010EA$0.00$0.00
02Size thru #795 KCM10EA$0.00$0.00
0035Replace or install or remove lightning arrester on existing energized primary power line10EA$0.00$0.00
0036Replace or install or remove load break, fused cutout on existing energized primary power line.10EA$0.00$0.00
0037Replace or install or remove solid blade, 200 amp knife switch on existing energized primary power line.10EA$0.00$0.00
0038Replace or install or remove load break, 200 amp, fused switch on existing energized primary power line10EA$0.00$0.00
0039Re-sag existing aerial primary or secondary span, 1PH or 3 PH, HDC, Stranded CU or ACSR$0.00
01Thru size #4/0. (per span).10EA$0.00$0.00
02Thru size #477. (per span).10EA$0.00$0.00
03Thru size #795. (per span).10EA$0.00$0.00
0040Install new pole mounted transformer, to include new Load Break Fused Cutouts, new Lightning Arresters, new Stirrups, new Hot Taps, new Ground Rods, new #4 BSDC Copper Lightning Arrestor down conductors and any additional hardware needed to make all connections$0.00
01Install new 15 KVA transformer5EA$0.00$0.00
02Install new 25 KVA transformer10EA$0.00$0.00
03Install new 37.5 KVA transformer10EA$0.00$0.00
04Install new 50 KVA transformer10EA$0.00$0.00
05Install new 75 KVA transformer5EA$0.00$0.00
06Install new 100 KVA transformer10EA$0.00$0.00
07Install new 167 KVA transformer10EA$0.00$0.00
0041Install rebuilt pole mounted transformer, to include new Load Break Fused Cutouts, new Lightning Arresters, new Stirrups, new Hot Taps, new Ground Rods, new #4 BSDC Copper Lightning Arrestor down conductors and any additional hardware needed to make all connections$0.00
01Install rebuilt 15 KVA transformer20EA$0.00$0.00
02Install rebuilt 25 KVA transformer10EA$0.00$0.00
03Install rebuilt 37.5 KVA transformer10EA$0.00$0.00
04Install rebuilt 50 KVA transformer10EA$0.00$0.00
05Install rebuilt 75 KVA transformer10EA$0.00$0.00
06Install rebuilt 100 KVA transformer10EA$0.00$0.00
07Install rebuilt 167 KVA transformer10EA$0.00$0.00
0042Remove existing Transformer and all related hardware from structure. (Thru 167 KVA)100EA$0.00$0.00
0043Install new ground rod 3/4" x 10' copper clad steel. To include clamp and conductor.50EA$0.00$0.00
0044Install new 1PH 4 thru 7 jaw ringless form 2S, 3S or 4S Meter Socket on new or existing structure. To include automatic circuit closures, rectangular NEMA 3R box, lockable hasp, flat polycarbonate cover, interchangeable hub and all connections to new or existing service5EA$0.00$0.00
0045Install new 1PH Class 10, 20 or 200 instrument rated watt-HR meter, with polycarbonate cover for 1PH, 3 wire, 120 or 240 volts, service into new or existing form 2S, 3S or 4S meter socket. Meter shall have encoded registers or a 2-wire pulse initiator with a 1-Kwh/pulse KYZ output cable to communicate with Teledata Corporation's model DC-4 Meter Interface Unit (MIU).5EA$0.00$0.00
0046Install new 3 PH 6 thru 13 jaw ringless form 6S, 7S, 8S or 9S Meter Socket on new or existing structure. To include automatic circuit closures, rectangular NEMA 3R box, lockable hasp, flat polycarbonate cover, interchangeable hub, and all connections to new or existing service5EA$0.00$0.00
0047Install new 3-Phase Class 10 or 20 instrument rated Watt-HR Demand Meter, with polycarbonate cover for 3 PH 3 or 4 wire, 120, 240, 277 or 480 volts, service into new or existing form 6S, 7S, 8S or 9S meter socket. Meter shall have encoded registers or a 2-wire pulse initiator with a 1-Kwh/pulse output to communicate with Teledata DC-4 MIU5EA$0.00$0.00
0048Provide NEMA 3, current transformer cabinet in new or existing facility and sized as required by the latest edition of the National Electrical Code to include current transformers sized per the specifications section 26 27 13.10 30, conductors and connections.

Provide Lonworks (WNC) Wattnode Electric Meter in NEMA 3, 8 inch tall x 10 inch wide x 4 inch deep enclosure with hinged door and lockable latch in new or existing facility. Mount at 48 inches above finished floor adjacent to CT cabinet.

Provide Lonworks (ILON 600) Smart Server in NEMA 3, 12 inch tall x 12 inch wide x 4 inch deep enclosure with hinged door and lockable latch. Mount at 48 inches above finished floor adjacent to communications board in new or existing facility.

Electric metering shall be purchased and installed per specifications Section 26 27 13.10 30 and shall include all conduits, conductors and connections required. Shall also include commissioning of meter to ensure ready for Fort Hood UMCS system5EA$0.00$0.00
01to provide and install .75 inch conduit with CAT 6, 3 conductor, #22 gauge, copper communications cable in new or existing facility between new Lonworks (WNC) Wattnode Electric Meter and Lonworks (ILON 600) Smart Server per electrical metering Specification 26 27 13.10 30.5LF$0.00$0.00
0049Install new Current Transformer (CT) on new or existing structure, Large Window Type (2-1/2" min.), Outdoor Use, 200:5 ratio, 600 Volt Class, 10 KV BIL, 3.0 continuous thermal rating factor. Route new or existing secondary service conductors through (CT). complete. To include hardware, mounting brackets, disconnection and reconnection of secondary conductors10EA$0.00$0.00
0050Install new Current Transformer (CT) on new or existing structure. Outdoor Use, 10:5 ratio through 100:5 ratio, 15 KV Class, 110 KV BIL, 3.0 Continuous thermal rating factor. Route new or existing primary conductors through (CT), complete. To include hardware, mounting brackets, disconnection and reconnection of primary conductors.10EA$0.00$0.00
0051Install new Potential Transformer (PT) on new or existing structure. Primary Service Type, Outdoor Use, 7200:120 ratio, 15 KV Class, 110 KV BIL, complete. To include hardware, mounting bracket10EA$0.00$0.00
0052Install new overhead 1PH triplex (ACSR) secondary service drop. Include connections at pole and at service entrance$0.00
01Size #6 triplex1000FT$0.00$0.00
02Size #4 triplex1000FT$0.00$0.00
03size #2 triplex1000FT$0.00$0.00
04Size #1/0 triplex1000FT$0.00$0.00
05Size #2/0 triplex1000FT$0.00$0.00
06Size #4/0 triplex1000FT$0.00$0.00
07Size #250 triplex1000FT$0.00$0.00
08Size #350 triplex1000FT$0.00$0.00
0053Install new overhead 3 PH quadruplexed (ACSR) secondary service drop. Include connections at pole and at service entrance$0.00
01Sizes thru #2 quadruplex1000FT$0.00$0.00
02Sizes thru #2/0 quadruplex1000FT$0.00$0.00
03Sizes thru #4/0 quadruplex1000FT$0.00$0.00
04Sizes thru #250 quadruplex1000FT$0.00$0.00
05Sizes thru #350 quadruplex1000FT$0.00$0.00
06Remove existing 1PH or 3 PH secondary service.20EA$0.00$0.00
0054Install new pole mounted High Pressure Sodium or Metal Halide sports flood light fixture. 120 – 480 volt as required. (See 16520 Sketch XL-4).$0.00
01400 watt20EA$0.00$0.00
021000 watt25EA$0.00$0.00
031500 watt20EA$0.00$0.00
0055Install new High Pressure Sodium or Metal Halide roadway light fixture. 120 – 480 volt as required. (See 16520 Sketch XL-9 and XL-10).$0.00
01150 watt10EA$0.00$0.00
02250 watt25EA$0.00$0.00
03400 watt10EA$0.00$0.00
041000 watt.10EA$0.00$0.00
05Remove existing roadway light fixture. To include all hardware and disconnection of circuit.10EA$0.00$0.00
0056Install new pole mounted LED Area flood light fixture. 120 – 480 volt as required. Refer to Attachment S$0.00
01Equivalent to 400W Metal Halide10EA$0.00$0.00
02Equivalent to 1000W Metal Halide10EA$0.00$0.00
03Equivalent to 1500W Metal Halide10EA$0.00$0.00
0057Install new LED Cobra Head roadway light fixture. 120 – 480 volt as required. Refer to Attachment S$0.00
01Equivalent to 150W Metal Halide10EA$0.00$0.00
02Equivalent to 250W Metal Halide10EA$0.00$0.00
03Equivalent to 400W Metal Halide10EA$0.00$0.00
04Equivalent to 1000W Metal Halide10EA$0.00$0.00
05Remove existing roadway light fixture. To include all hardware and disconnection of circuit.10EA$0.00$0.00
0058Install new 35 foot, class 5 concrete lighting pole, complete. To include ground rod system, all connections to power source and lighting system. (See 16520 Sketch XL-15, XL-16 and XL-27).5EA$0.00$0.00
0059Install new steel lighting pole, complete to include concrete foundation. To include ground rod system, all connections to power source and lighting system. (See Sketch 16520 XL-19 and XL-20)$0.00
01Thru 30 foot steel pole5EA$0.00$0.00
02Thru 50 foot steel pole5EA$0.00$0.00
03Thru 75 foot steel pole5EA$0.00$0.00
04Remove existing steel pole, to exclude foundation.5EA$0.00$0.00
0060Install steel 1 luminaire bracket type arm for mounting roadway light fixtures on poles$0.00
016' steel bracket type arm10EA$0.00$0.00
0210’ steel bracket type arm10EA$0.00$0.00
0312’ steel bracket type arm10EA$0.00$0.00
0061Install steel luminaire bracket type arm for mounting sports light fixtures on poles. (See 16520 Sketch XL-21, “A”, “B”, “C” or “D”).$0.00
011 luminaire, angle bracket5EA$0.00$0.00
022 luminaire mounting bracket5EA$0.00$0.00
033 luminaire mounting bracket5EA$0.00$0.00
044 luminaire mounting bracket5EA$0.00$0.00
056 luminaire mounting bracket5EA$0.00$0.00
0062Install new steel reinforced concrete base foundation for steel light poles. To include steel reinforced concrete base foundation, galvanized anchor bolts, nuts and washers, ground rod system, all connections to power source and lighting system. (See 16520 Sketch XL-26).$0.00
0124" diameter by 6-1/2’ deep steel reinforced concrete base3EA$0.00$0.00
0224" diameter by 6-1/2’ deep steel reinforced concrete base with 36” of concrete pier above finished grade.3EA$0.00$0.00
0336" diameter by 10’ deep steel reinforced concrete base3EA$0.00$0.00
0436" diameter by 10’ deep steel reinforced concrete base with 36” of concrete pier above finished grade3EA$0.00$0.00
0536" diameter by 18’ deep steel reinforced concrete base with 36” of concrete pier above finished grade.3EA$0.00$0.00
06Remove up to 24" diameter by 6-1/2’ deep existing steel reinforced concrete pier base. To include removal of underground conduits and conductors3EA$0.00$0.00
07Remove up to 48" diameter existing steel reinforced concrete pier base to 4 feet below grade. To include removal of underground conduits and conductors3EA$0.00$0.00
0063Install new weatherproof photo-electric light control system, 1PH or 3PH, 120 – 480 volt as required. To include weatherproof enclosure, twist lock photo-electric cell, lighting contactor, conductors, 3-position "HAND-OFF-AUTO" control, fused disconnect switch as required, service riser (not to exceed 30') of galvanized rigid conduit with conductors as required, weather head, fasteners, hubs, fittings, ground rod system, all connections to power source and lighting system.$0.00
0130 amp light control system5EA$0.00$0.00
0260 amp light control system5EA$0.00$0.00
03100 amp light control system3EA$0.00$0.00
04Install new weatherproof photo-electric light control system for sports fields, 3PH, 120 – 480 volt as required. To include weatherproof enclosure, twist lock photo-electric cell, up to 4 each 100 amp lighting contactors, control conductors, 3-position "HAND-OFF-AUTO" control mounted inside of enclosure, hubs, fittings, lockable hasp for weather-proof enclosure, all connections to power source and lighting system. (Not to include mounting rack, concrete pad or panel board)1EA$0.00$0.00
05Install new weatherproof photo-electric light control system for sports fields, 3PH, 120 – 480 volt as required. To include weatherproof enclosure, twist lock photo-electric cell, up to 6 each 100 amp lighting contactors, control conductors, 3-position "HAND-OFF-AUTO" control mounted inside of enclosure, hubs, fittings, lockable hasp for weather-proof enclosure, all connections to power source and lighting system. (Not to include mounting rack, concrete pad or panel board).1EA$0.00$0.00
0064Install high mast light tower. To include up to 100 foot tall galvanized steel pole, mast ring, double obstruction lights, aerial lightning rod, up to 1000 watt HPS or MH light fixtures or LED equivalent, 120 – 480 volt as required, hoist, hoist cables, electric powered hoist motor, 25 foot of electric hoist remote control with cabling and control box, all electrical power cables, service cables, twist lock connectors, internal electrical disconnect breaker, mounting brackets, galvanized anchor bolts, nuts and washers, hardware, ground rod system, all connections to power source, lighting system and other necessary accessories. Complete, To include 18 foot deep x 36 inch wide steel reinforced concrete pier baser. Concrete base shall extend 36 inches above finished grade. (Not to include underground conduits or lighting controller).$0.00
01High mast light tower with up to 4 each, 1000 watt HPS or MH light fixtures1EA$0.00$0.00
02High mast light tower with up to 4 each, LED light fixtures equivalent to 1000 watt HPS or MH light fixtures1EA$0.00$0.00
03High mast light tower with up to 8 each, 1000 watt HPS or MH light fixtures.1EA$0.00$0.00
04High mast light tower with up to 8 each, LED light fixtures equivalent to 1000 watt HPS or MH light fixtures1EA$0.00$0.00
05High mast light tower with up to 12 each, 1000 watt HPS or MH light fixtures1EA$0.00$0.00
06High mast light tower with up to 12 each, LED light fixtures equivalent to 1000 watt HPS or MH light fixtures1EA$0.00$0.00
07Install 1 high mast 1000 watt HPS or MH light fixture12EA$0.00$0.00
08Install 1 high mast LED light fixture equivalent to 1000 watt HPS or MH light fixture12EA$0.00$0.00
09Install up to 100 foot tall galvanized steel pole1EA$0.00$0.00
0065Repair in-operable high mast light tower up to 110 feet above grade. Inspect, adjust, grease and tighten luminaire ring assembly, centering springs, rubber wheels, eye bolts, pulleys, etc. and lower stuck luminaire ring to ground level for repairs5EA$0.00$0.00
01Replace damaged stainless steel hoist cables inside of pole. (When repairs are paid for under Item X059).250FT$0.00$0.00
02Replace damaged electrical power cable inside of pole. (When repairs are paid for under Item X059).250FT$0.00$0.00
0066Re-lamp/Repair existing sports light fixtures mounted up to 120 feet above grade and up to 1500 watts, HPS or MH. Inspect, adjust, aim, clean, grease and tighten luminaire assembly$0.00
01Re-lamp up to 10 each existing sports lights with up to 1500 watt, HPS or MH lamps1EA$0.00$0.00
02Re-lamp up to 30 each existing sports lights with up to 1500 watt, HPS or MH lamps1EA$0.00$0.00
03Re-lamp up to 60 each existing sports lights with up to 1500 watt, HPS or MH lamps.1EA$0.00$0.00
04Re-lamp up to 100 each existing sports lights with up to 1500 watt, HPS or MH lamps1EA$0.00$0.00
05Replace existing sports light ballast to include new starters/igniters, capacitors and fuses with up to 1500 watt, HPS or MH ballasts. (When lamp replacement is paid for under Item X060).1EA$0.00$0.00
06Replace up to 10 each existing sports light ballasts to include new starters/igniters, capacitors and fuses with up to 1500 watt, HPS or MH ballasts. (When lamp replacement is paid for under Item X060).1EA$0.00$0.00
07Replace up to 30 each existing sports light
ballasts to include new starters/igniters, capacitors and fuses with up to 1500 watt, HPS or MH ballasts. (When lamp replacement is paid for under Item X060).1EA$0.00$0.00
0067Install pole-mounted solar lighting fixture assembly consisting of solar panel, luminaire with battery-operated 32-watt compact fluorescent bulb, batteries, charger, controller, mounting brackets, hardware and other necessary accessories. Complete, To include steel reinforced concrete pier base designed and recommended by manufacturer and up to a 30 foot steel or aluminum pole. Concrete pier base shall extend 36 inches above finished grade).1EA$0.00$0.00
0068Install pole-mounted, solar, dual flashing beacon, with 36 inch x 36 inch, yellow “Caution Troop Crossing” roadway sign or sign as indicated, assembly consisting of solar panel, luminaire with battery-operated compact fluorescent or LED bulbs, batteries, charger, controller, mounting brackets, galvanized anchor bolts, nuts and washers, hardware and other necessary accessories. Complete, To include steel reinforced concrete pier base designed and recommended by manufacturer and up to a 20 foot steel or aluminum pole1EA$0.00$0.00
0069Replace or Install pole-mounted obstruction light on up to a 60 foot tall pole. To include up to 20 feet of galvanized rigid conduit, conductors, mounting brackets, hardware, connections and other necessary accessories. (See 16510 Sketch NL-70).$0.00
01Single pole-mounted obstruction light2EA$0.00$0.00
02Double pole-mounted obstruction light2EA$0.00$0.00
0070Replace or Install pole-mounted obstruction light on up to a 80 foot tall pole. To include up to 20 feet of galvanized rigid conduit, conductors, mounting brackets, hardware, connections and other necessary accessories. (See 16510 Sketch NL-70).$0.00
01Single pole-mounted obstruction light2EA$0.00$0.00
02Double pole-mounted obstruction light2EA$0.00$0.00
0071Install new FM control switch, Comverge Technologies Model DCU-2052B-02-04-S, for exterior lighting, on new or existing structure to include a 250V, AC, 30 Amp contact rated off-board relay, 250V, AC, 5 Amp contact rated on-board relay and 120/240V, AC, rated transformer. DCU must operate a frequency of 139.650 MHz1EA$0.00$0.00
0072Install twist lock photocell in weatherproof box for HID floodlights. To include mounting hardware for pole or wall mounting and connection to circuit5EA$0.00$0.00
0073Install or replace twist lock photocell on existing roadway lighting fixture. To include connection to circuit4EA$0.00$0.00
0074Removal of existing 1 PH or 3 PH service equipment on poles or in buildings. To include service risers, service disconnect switches, feeder conductors, conduits, fused safety switches or breaker panels$0.00
01Not to exceed 100 Amp5EA$0.00$0.00
02Not to exceed 200 Amp5EA$0.00$0.00
03Not to exceed 400 Amp.5EA$0.00$0.00
04Not to exceed 800 Amp.5EA$0.00$0.00
0075Install service riser on poles or buildings for 1PH or 3 PH service (not to exceed 20') of galvanized rigid conduit and conductors as required. To include weatherhead, fasteners, hub, mounting hardware, and fittings.$0.00
01#8 THWN CU20EA$0.00$0.00
02#4 THWN CU20EA$0.00$0.00
03#1/0 THWN CU, 1 PH20EA$0.00$0.00
04#1/0 THWN CU, 3 PH20EA$0.00$0.00
05#4/0 THWN CU, 1 PH20EA$0.00$0.00
06#4/0 THWN CU, 3 PH5EA$0.00$0.00
07#600 THWN CU, 3 PH5EA$0.00$0.00
08#750 THWN CU, 3 PH5EA$0.00$0.00
0076Install service riser on poles or buildings for 1PH or 3 PH service (not to exceed 30') of galvanized rigid conduit and conductors as required. To include weather head, fasteners, hub, mounting hardware, and fittings.$0.00
01#1/0 THWN CU, 1 PH10EA$0.00$0.00
02#1/0 THWN CU, 3 PH10EA$0.00$0.00
03#4/0 THWN CU, 1 PH10EA$0.00$0.00
04#4/0 THWN CU, 3 PH3EA$0.00$0.00
05#600 THWN CU, 3 PH2EA$0.00$0.00
06#750 THWN CU, 3 PH1EA$0.00$0.00
07Remove existing service riser, thru #4, 1 or 3 PH1EA$0.00$0.00
08Remove existing service riser, thru #4/0, 1 or 3 PH3EA$0.00$0.00
09Remove existing service riser, thru #750, 1 or 3 PH3EA$0.00$0.00
0077Install roof jack using galvanized rigid conduit as required. To include weather head, up to 4 conductors, roof seal and mounting hardware.$0.00
01Size thru #1/0 KCM THWN CU3EA$0.00$0.00
02Size thru #4/0 KCM THWN CU3EA$0.00$0.00
03Size thru #300 KCM THWN CU3EA$0.00$0.00
04Size thru #750 KCM THWN CU3EA$0.00$0.00
0078Install safety switch, 1PH or 3 PH, 240V, fused, H.D., NEMA 3R, on existing or new structure. Include solid neutral bar and grounding bars$0.00
0130 Amp3EA$0.00$0.00
0260 Amp.3EA$0.00$0.00
03100 Amp.3EA$0.00$0.00
04200 Amp3EA$0.00$0.00
05400 Amp.3EA$0.00$0.00
06800 Amp1EA$0.00$0.00
071000 Amp1EA$0.00$0.00
08Remove existing safety switch thru 100 Amp.3EA$0.00$0.00
09Remove existing safety switch thru 200 Amp3EA$0.00$0.00
10Remove existing safety switch thru 400 Amp.3EA$0.00$0.00
11Remove existing safety switch thru 1000 Amp.3EA$0.00$0.00
0079Install safety switch, 3 PH, 600V, fused, H.D., NEMA 3R, on existing or new structure. Include solid neutral bar and grounding bars$0.00
0130 Amp3EA$0.00$0.00
0260 Amp3EA$0.00$0.00
03100 Amp3EA$0.00$0.00
04200 Amp3EA$0.00$0.00
05400 Amp1EA$0.00$0.00
06800 Amp.1EA$0.00$0.00
071000 Amp1EA$0.00$0.00
0080Install switch rack constructed with a minimum of 2 each, 3 inch galvanized pipe posts concrete encased 36 inches deep, 3 inch galvanized steel pipe caps, 1-1/2 inch galvanized channel iron and all hardware required to mount switches, wiring gutters, panel boards, etc.$0.00
01Switch rack up to 5 feet wide2EA$0.00$0.00
02Switch rack up to 10 feet wide2EA$0.00$0.00
03Switch rack up to 15 feet wide2EA$0.00$0.00
0081Install new weatherproof wiring gutter with removable front cover. To include all wiring and connections$0.00
016” x 6”, up to #4/0 THWN CU50FT$0.00$0.00
028” x 8”, up to #600 KCM THWN CU25FT$0.00$0.00
0312” x 12”, up to #600 KCM THWN CU25FT$0.00$0.00
0082Install NEMA 3 weatherproof junction box$0.00
01Up to 12"x12"x8"2EA$0.00$0.00
02Up to 24"x24"x8"2EA$0.00$0.00
0083Install new 3/4" x 8' copper clad steel ground rod, complete. To include galvanized rigid conduit, clamp and ground conductor. (Not to exceed 10' per conductor).5EA$0.00$0.00
0084Test existing lightning, static ground conductors or static grounding points for continuity at ammo bunkers, ammunition holding areas, railheads, poles or buildings as required by DA PAM 385-64 and FM 10-67-1. Visually inspect, disconnect mechanical connections or isolate grounding run by cutting conductors at each test point. Provide written test reports and as-built drawings with ohm recording of each test point to COR.$0.00
01Visually inspect and test conductors for continuity at up to 20 each test points between poles or at buildings up to 15 feet above grade.3EA$0.00$0.00
02Visually inspect and test conductors for continuity at up to 20 each test points between poles or at buildings up to 60 feet above grade.1EA$0.00$0.00
03Visually inspect and test conductors for continuity at up to 50 each test points between poles or at buildings up to 15 feet above grade.1EA$0.00$0.00
04Visually inspect and test conductors for continuity at up to 50 each test points between poles or at buildings up to 60 feet above grade1EA$0.00$0.00
05Visually inspect and test conductors for continuity at up to 100 each test points between poles or at buildings up to 15 feet above grade1EA$0.00$0.00
06Visually inspect and test conductors for continuity at up to 100 each test points between poles or at buildings up to 60 feet above grade1EA$0.00$0.00
07Visually inspect and test conductors for continuity at up to 200 each test points between poles or at buildings up to 15 feet above grade.1EA$0.00$0.00
08Visually inspect and test conductors for continuity at up to 200 each test points between poles or at buildings up to 60 feet above grade.1EA$0.00$0.00
09Replace or Install up to 4 foot long copper aerial lightning rod on ammo bunker vent, buildings, wood or steel poles, up to 15 feet above grade, to include mounting brackets, hardware, connections and other necessary accessories.1EA$0.00$0.00
10Replace or Install up to 4 foot long copper aerial lightning rod on buildings, wood or steel poles, up to 60 feet above grade, to include mounting brackets, hardware, connections and other necessary accessories.1EA$0.00$0.00
11Replace or Install up to #2/0 braided copper lightning conductor, surface mounted on ammo bunkers, buildings, wood poles or inside of steel poles, up to 15 feet above grade, to include copper straps mounted every 4 feet, connections and other necessary accessories.200FT$0.00$0.00
12Replace or Install up to #2/0 braided copper lightning conductor, surface mounted on ammo bunkers, buildings, wood poles or inside of steel poles, up to 60 feet above grade, to include copper straps mounted every 4 feet, connections and other necessary accessories200FT$0.00$0.00
13Replace or Install up to #4/0 braided copper lightning conductor, surface mounted on ammo bunkers, buildings, wood poles or inside of steel poles, up to 15 feet above grade, to include copper straps mounted every 4 feet, connections and other necessary accessories.50FT$0.00$0.00
14Replace or Install up to #4/0 braided copper lightning conductor, surface mounted on ammo bunkers, buildings, wood poles or inside of steel poles, up to 60 feet above grade, to include copper straps mounted every 4 feet, connections and other necessary accessories.50FT$0.00$0.00
15Install up to #2/0 braided copper lightning conductor. To include excavation 3 feet below finished grade, backfill, conductors, connections and restoration of surface area to match original conditions to include solid sod in turfed areas and hydro mulch or grass seed as specified in all other areas50FT$0.00$0.00
16Install up to #4/0 braided copper lightning conductor. To include excavation 3 feet below finished grade, backfill, conductors, connections and restoration of surface area to match original conditions, to include solid sod in turfed areas and hydro mulch or grass seed as specified in all other areas.50FT$0.00$0.00
17Replace or Install up to 5 each mechanical or compression connections on lightning conductors. To include disconnection of old connection and installation of new connection.1EA$0.00$0.00
18Replace or Install up to 20 each mechanical or compression connections on lightning conductors. To include disconnection of old connection and installation of new connection.1EA$0.00$0.00
19Replace or Install up to 50 each mechanical or compression connections on lightning conductors. To include disconnection of old connection and installation of new connection.2EA$0.00$0.00
20Replace or Install up to 100 each mechanical or compression connections on lightning conductors. To include disconnection of old connection and installation of new connection1EA$0.00$0.00
21Test up to 5 each ground rods or static ground points5EA$0.00$0.00
22Test up to 20 each ground rods or static ground points2EA$0.00$0.00
23Test up to 50 each ground rods or static ground points2EA$0.00$0.00
24Test up to 100 each ground rods or static ground points.2EA$0.00$0.00
25Test up to 200 each ground rods or static ground points1EA$0.00$0.00
26Test up to 300 each ground rods or static ground points1EA$0.00$0.00
0085Paint static ground points as required by FM 10-67-1. Encircle each grounding point on hard surfaces with a permanently painted, fuel proof, 18 inch diameter yellow circle with a 2 inch red border surrounding it. Stencil in black the words STATIC GROUND CONNECTION and a numeric or alphanumeric rod identification code in the circles yellow portion. encil in black the OHMS to ground recorded and date of testing.$0.00
01Paint up to 10 each static ground points.1EA$0.00$0.00
02Paint up to 30 each static ground points1EA$0.00$0.00
03Paint up to 50 each static ground points.1EA$0.00$0.00
04Paint up to 100 each static ground points.1EA$0.00$0.00
05Paint up to 200 each static ground points.1EA$0.00$0.00
06Paint up to 300 each static ground points.1EA$0.00$0.00
0086Install 120/240V, Panel board, surface mounted, copper bus bars and bolt in breakers, in the vicinity of existing service equipment (within 10'). To include mounting hardware, feeder conductors, connections, raceway, solid neutral bar and grounding bars as required. (Not to include feeder breakers).$0.00
01100 Amp, 1PH, 20 circuit, #1/0 THWN CU3EA$0.00$0.00
02100 Amp, 1PH, 20 circuit, #1/0 THWN CU with Main breaker3EA$0.00$0.00
03100 Amp, 3 PH, 30 circuit, #1/0 THWN CU3EA$0.00$0.00
04100 Amp, 3 PH, 30 circuit, #1/0 THWN CU with Main breaker3EA$0.00$0.00
05225 Amp, 1PH, 42 circuit, #4/0 THWN CU.3EA$0.00$0.00
06225 Amp, 1PH, 42 circuit, #4/0 THWN CU with Main Breaker3EA$0.00$0.00
07225 Amp, 3 PH, 42 circuit, #4/0 THWN CU3EA$0.00$0.00
08225 Amp, 3 PH, 42 circuit, #4/0 THWN CU with Main Breaker3EA$0.00$0.00
09225 Amp, 3 PH, 42 circuit, #4/0 THWN CU. NEMA 3R.3EA$0.00$0.00
10225 Amp, 3 PH, 42 circuit, #4/0 THWN CU. NEMA 3R with main breaker3EA$0.00$0.00
11400 Amp, 3 PH, 42 circuit, #600 THWN CU. NEMA 1 or 3R.2EA$0.00$0.00
12400 Amp, 3 PH, 42 circuit, #600 THWN CU. NEMA 1 or 3R with main breaker3EA$0.00$0.00
13600 Amp, 3 PH, 42 circuit, 2 - #250 THWN CU. NEMA 1 or 3R.2EA$0.00$0.00
14600 Amp, 3 PH, 42 circuit, 2 - #250 THWN CU. NEMA 1 or 3R with main breaker3EA$0.00$0.00
15800 Amp, 3 PH, 42 circuit, 2 - #400 THWN CU. NEMA 1 or 3R.2EA$0.00$0.00
16800 Amp, 3 PH, 42 circuit, 2 - #400 THWN CU. NEMA 1 or 3R.with main breaker3EA$0.00$0.00
17Remove existing panel board thru 125 Amp3EA$0.00$0.00
18Remove existing panel board thru 225 Amp3EA$0.00$0.00
19Remove existing panel board thru 400 Amp3EA$0.00$0.00
20Remove existing panel board thru 600 Amp3EA$0.00$0.00
21Remove existing panel board thru 800 Amp3EA$0.00$0.00
0087Install 120 thru 240 volt circuit breaker in new or existing panel board$0.00
011 Pole, 15 thru 60 Amp5EA$0.00$0.00
022 Pole, 15 thru 60 Amp5EA$0.00$0.00
033 Pole, 15 thru 60 Amp5EA$0.00$0.00