A-601 - Finish Schedule - Amendment 001.pdf

PDF 1 MB Posted

Attached to
Construct Aircraft Support Equipment (ASE) and Vehicle Maintenance (VM) Facility, Bradley Air National Guard Base, CT
Solicitation number
W50SC2-23-R-0001
Issued by

About this file

This document provides details for a federal contract solicitation to construct an Aircraft Support Equipment (ASE) and Vehicle Maintenance (VM) facility at Bradley Air National Guard Base in East Granby, Connecticut. The solicitation seeks to award a single contract between $10-25 million to perform work in accordance with contract drawings and technical specifications. The North American Industry Classification code for this project is 236220 for commercial and institutional building construction, with a small business size standard of $39.5 million average annual revenue. Funds have not yet been appropriated for this acquisition but are anticipated to be available prior to award, as the project has been identified on the National Guard's priority list. No contract will be awarded until funds are made available.

View the file

Other files

File Type Posted
CEKT179200 Geotechnical Report - CTANG - Final.pdf PDF
W50SC2-23-R-0001 Amendment 0002 SF 30.pdf PDF
C-304 - Civil Details_Amendment 002.pdf PDF
122413 - Roller Window Shades_Amendment 002.pdf PDF
104416 FL - Fire Extinguishers_Amendment 002.pdf PDF
FS001_Amendment 002.pdf PDF
W50SC223R0001 RFI Log 20230118.pdf PDF
CTANG ASE-VMXS _ RPF Building Survey Report October 2019_Amendment 002.pdf PDF
024119 FL - Selective Demolition_Amendment 002.pdf PDF
W50SC2-23-R-0001 Amendment 0001 SF 30.pdf PDF
Small Business Participation Plan Form.pdf PDF
329300 - Plants_Amendment 001.pdf PDF
A-130 - A-137 - RCPs_ Amendment 001.pdf PDF
A-610 - Door Schedule_Amendment 001.pdf PDF
101400 - Signage_Amendment 001.pdf PDF
C-304 - Civil Details_Amendment 001.pdf PDF
329113 - Soil Preparation_Amendment 001.pdf PDF
311000 - Site Clearing_Amendment 001.pdf PDF
334200 - Stormwater Conveyance_Amendment 001.pdf PDF
093013 Ceramic Tiling_Amendment 001.pdf PDF
C-306 - Civil Details_Amendment 001.pdf PDF
W50SC223R0001 RFI Log 20230112.pdf PDF
Pre-Proposal Conference Attendance Sheet 20230105.pdf PDF
CE Pre-Proposal Slides.pdf PDF
Contracting Pre-Proposal Slides.pdf PDF
W50SC223R0001 RFI Log 20221228.pdf PDF
W50SC223R0001 RFI Log 20221222.pdf PDF
W50SC223R0001 RFI Log 20221201.pdf PDF
Brand Name JA CEKT179200 signed.pdf PDF
W50SC2-23-R-0001.pdf PDF
Mandatory Signs 2.pdf PDF
Manadatory Door Hardware.pdf PDF
EXHIBIT B - Subcontractor Information and Consent Form.docx DOCX document
EXHIBIT D - Letter of Commitment ok Key Personnel.docx DOCX document
Mandatory Signs 1.pdf PDF
EXHIBIT A - Performance Relevancy Questionnaire.docx DOCX document
Mandatory Sign Part Numbers.pdf PDF
EXHIBIT C - Reference_Questionnaire_Package.docx DOCX document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ROOM FINISH SCHEDULE

GENERAL NOTES

1. REFER TO PLANS FOR PARTITION TYPES.

2. PROVIDE "V" SHAPED CONTROL JOINT IN GYPSUM BOARD ASSEMBLIES

AT 30'-0" ON CENTER MAXIMUM OR AS NOTED. COORDINATE LOCATIONS

WITH COR PRIOR TO CONSTRUCTION.

3. PROVIDE FIRESTOPPING AT PERIMETERS AND PENETRATIONS OF FIRE

RATED GYPSUM BOARD ASSEMBLIES.

4. PROVIDE APPROPRIATE TRANSITION STRIPS AT ALL CHANGES IN FLOOR

FINISH MATERIALS. REFER TO TYPICAL TRANSITION DETAILS.

5. PAINT ALL STEEL DOORS AND FRAMES.

6. ALL FINISHES SHALL BE APPROVED BY THE CONNECTICUT AIR

NATIONAL GUARD PRIOR TO INSTALLATION.

7. FOR EXTERIOR COLOR SCHEDULE, REFERENCE EXTERIOR ELEVATIONS.

8. PROVIDE WATER RESISTANT GYPSUM BOARD AT PARTITIONS WITH

PLUMBING FIXTURES AND THROUGHOUT TOILET AND SHOWER ROOMS

UNLESS OTHERWISE NOTED.

9. ALL PIPING NOT CONCEALED IN PARTITIONS OR ABOVE CEILING SHALL

BE PAINTED. REFER TO SPECIFICATIONS.

10. PROVIDED IMPACT RESISTANT GYPSUM BOARD TO 8'-0" AFF.

11. PAINT ALL SURFACES VISIBLE ABOVE FINISH CEILING AS SPECIFIED.

12. DO NOT INSTALL RUBBER BASE ON OPERABLE PARTITION.

13. DO NOT INSTALL RUBBER BASE ON CMU PARTITIONS AND WALLS.

14. REFER TO INTERIOR ELEVATIONS FOR LOCATIONS OF FINISHES.

15. AT ALL ROOMS DESIGNATED AS "IT", "TELECOMMUNICATION", OR

"TELECOM", PROVIDE 3/4", A/C GRADE OR BETTER, VOID-FREE, FIRE-

RESISTANT PLYWOOD KILN-DRIED TO MAX MOISTURE CONTENT OF 15

PERCENT, ON FACE OF ALL PARTITIONS. COORDINATE WITH TELECOM

REQUIREMENTS. EXTEND PLYWOOD FROM FLOOR TO 8'-0" AFF. AND

FASTEN TO SEEL STUDS WITH 2" SCREWS AT 16" O.C.; GYPSUM BOARD

CONCEALED BY PLYWOOD NEED NOT BE PAINTED.

16. PAINT ALL EXPOSED STEEL COLUMNS, BRACES, GIRTS, DECKS, AND

MISCELLANEOUS STEEL FRAMING UNLESS OTHERWISE NOTED.

A

Designed:

Drawn:

Checked:

Date:

Drawing Title:

Jacobs Project No.: D3257200

B

C

D

2 3 4 5

Scales:

THESE DOCUMENTS ARE FOR

INTERIM REVIEW AND NOT FOR

CONSTRUCTION, BIDDING, OR

PERMIT PURPOSES.

AS INDICATED

Phase: B-3 FINAL DESIGN

C O

N N

E C

T

IC

U T

A

IR

N A

T

IO

N A

L G

U A

R D

R

D A

IR

L

IF

T

W

IN

G

B R

A D

L E

Y A

IR

N

A T

IO

N

A L

G

U A

R D

B A

S E

E A

S T

G R

A N

B Y

C

O N

N E

C T

IC

U

T

C O

M P

O S

IT

E

A S

E A

N D

V

M X

S F

A C

IL

IT

Y

Drawing No.:

ARCHITECTURAL

B

IM

/U

S C

T D

C

A N

G A

S E

-V M

X S

F a c ili ty /D

C

T A

N G

A

S E

-V M

X S

F A

C

IL

IT

Y

A

R C

H .r v t

/1

/2

:0

:5

A

M

B. HENDON

J. McKINNEY

J. PERRY

03/31/2022

A-601

FINISH SCHEDULE &

TOILET ACCESSORIES

SCHEDULE

ROOM FINISH SCHEDULE

ROOM

NO. ROOM NAME

FLOOR WALLS CEILING

REMARKSMATERIAL FINISH

WALL

BASE

NORTH PARTITION EAST PARTITION SOUTH PARTITION WEST PARTITION

MATERIAL FINISHMATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH

100 VESTIBULE WM-1 - RB-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 RECESSED FLOOR MAT W/ DRAIN

101 LOBBY LVT-1 - RB-1 GYP PT-2 GYP PT-2 GYP PT-2 GYP PT-2 APC - FEATURE WALL ON SOUTH WALL

102 CORRIDOR LVT-1 - RB-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 APC - -

104 ASE OPEN OFFICE CPT-1 - RB-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 APC - -

104A OFFICE CPT-1 - RB-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 APC - -

105 CONFERENCE CPT-1 - RB-1 GYP PT-2 GYP PT-2 GYP PT-2 GYP PT-2 APC / GYP - PAINTED GYP CEILING AT PARTITION

TRACK

106 JAN EP-1 - EP-1 GYP - GYP PT-1 GYP - GYP - - - -

107 DISTRIBUTION ESD - RB-1 GYP - GYP - GYP - GYP - - - STATIC-CONTROL RESILIENT

FLOORING

108 LAUNDRY EP-1 - EP-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 -

109 ELEC CONC SEALED RB-1 GYP - GYP - GYP - GYP - - - CEILING OPEN TO STRUCTURE ABOVE

110 VMXS OPEN

OFFICE

CPT-1 - RB-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 APC - -

110A OFFICE CPT-1 - RB-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 APC - -

110B OFFICE CPT-1 - RB-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 APC - -

111 MEN'S LOCKER/

RESTROOM

PFT-1 - TILE

BASE

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

GYP SEE

REMARKS

SEE PLAN, ELEVATIONS, & DETAILS

FOR LOCATIONS OF FINISHES

111A MENS VESTIBULE LVT-1 - RB-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 -

112 WOMEN'S

LOCKER/

RESTROOM

PFT-1 - TILE

BASE

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

SEE

REMARKS

GYP SEE

REMARKS

112A WOMENS

VESTIBULE

LVT-1 - RB-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 -

113 VESTIBULE WM-1 - RB-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 GYP PT-1 -

114 VMXS

MAINTENANCE

AND REPAIR

EP-1 - EP-1 CMU - CMU - CMU - CMU - - PT-3 EPOXY RESIN FLOORING WITH

INTEGRAL BASE

114A EQUIPMENT

PLATFORM

EP-1 - EP-1 CMU - CMU - CMU - CMU - - PT-3 EPOXY RESIN FLOORING WITH

INTEGRAL BASE

115 VMXS TOOL CRIB EP-1 - EP-1 CMU - CMU - CMU - CMU - - PT-3 EPOXY RESIN FLOORING WITH

INTEGRAL BASE

116 MECHANICAL CONC SEALED RB-1 CMU - CMU - CMU - CMU - - PT-3 EPOXY RESIN FLOORING WITH

INTEGRAL BASE

117 BATTERY EP-1 - EP-1 CMU - CMU - CMU - CMU - - PT-3 ACID-ALKALI RESISTANT EPOXY RESIN

FLOORING WITH INTEGRAL BASE

119 REFUELING

VEHICLE SHOP

EP-1 - EP-1 CMU - CMU - CMU - CMU - - PT-3 EPOXY RESIN FLOORING WITH

INTEGRAL BASE

120 WASH RACK EP-1 - EP-1 CMU - CMU - CMU - CMU - - PT-3 EPOXY RESIN FLOORING WITH

INTEGRAL BASE

121 ASE

MAINTENANCE

AND REPAIR

EP-1 - EP-1 CMU - CMU - CMU - CMU - - PT-3 EPOXY RESIN FLOORING WITH

INTEGRAL BASE

122 ASE TOOL CRIB EP-1 - EP-1 CMU - CMU - CMU - CMU - - PT-3 EPOXY RESIN FLOORING WITH

INTEGRAL BASE

123 WASH RACK EP-1 - EP-1 CMU - CMU - CMU - CMU - - PT-3 OLI WASH RACK; EPOXY RESIN

FLOORING WITH INTEGRAL BASE

124 ASE STORAGE EP-1 - EP-1 CMU - CMU - CMU - CMU - - PT-3 EPOXY RESIN FLOORING WITH

INTEGRAL BASE. PROVIDE SEALED

CONCRETE FOR OUTDOOR CONCRETE

SLAB AT ASE STORAGE 124.

S101 HEATED VEHICLE

OPS STORAGE

EP-1 - EP-1

S102 COVERED

VEHICLE OPS

PARKING

CONC SEALED PROVIDE SEALED CONCRETE FOR

OUTDOOR CONCRETE SLAB AT

COVERED VEHICLE OPS PARKING S102

SCD SEAT COVER DISPENSER

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N RECESSED, STAINLESS STEEL, SATIN FINISH

US UTILITY SHELF

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N SURFACE MOUNTED, STAINLESS STEEL, SATIN FINISH

WR WASTE RECEPTACLE

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N SEMI-RECESSED, STAINLESS STEEL, SATIN FINISH

TTD TOILET TISSUE DISPENSER

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N

SURFACE MOUNTED MULTI-ROLL, STAINLESS STEEL , SATIN

FINISH

SD SOAP DISPENSER

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N SURFACE MOUNTED SOAP DISPENSER

SCR SHOWER CURTAIN ROD

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N SURFACE MOUNTED, STAINLESS STEEL, SATIN FINISH

SC

VINYL SHOWER CURTAIN & SHOWER

CURTAIN HOOKS

- N -

RSD

RECESSED SOAP DISH - 7-3/16" W X 5" H

X 3-1/2" D

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N STAINLESS STEEL, SATIN FINISH

RH ROBE HOOK

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N SURFACE MOUNTED, STAINLESS STEEL, SATIN FINISH

PTD PAPER TOWEL DISPENSER

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N SURFACE MOUNTED, STAINLESS STEEL, SATIN FINISH

MR 24" x 48" MIRROR

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N 1/4" FLOAT GLASS; SURFACE MOUNTED

GB-3 GRAB BAR - 1-1/4" DIA. X 24"

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N

STAINLESS STEEL, SATIN FINISH WITH PEENED GRIP;

SURFACE MOUNT

GB-2 GRAB BAR - 1-1/4" DIA. X 36"

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N

STAINLESS STEEL, SATIN FINISH WITH PEENED GRIP;

SURFACE MOUNT

GB-1 GRAB BAR - 1-1/4" DIA. X 42"

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N

STAINLESS STEEL, SATIN FINISH WITH PEENED GRIP; SURFACE

MOUNT

FSS FOLDING SHOWER SEAT

REFER TO A-450 - TYPICAL

MOUNTING HEIGHTS

N

SURFACE MOUNTED; REFER TO PLAN TO DETERMINE RIGHT

OR LEFT HANDEDNESS

ITEM ACCESSORY DESCRIPTION MOUNTING HEIGHT (AFF)

ELECTRIC

POWER (Y/N)

REMARKS

TOILET ACCESSORIES SCHEDULE

WM-1 CASTLE GREY - -

SS-1 WHITE STONE - -

RB-1 GRAY HAZE - -

PWT-2 MIST 12" X 24" ACCENT PORCELAIN WALL TILE

PWT-1 DAWN 12" X 24" FIELD PORCELAIN WALL TILE

PT-3 DISTANCE -

ACCENT / SIGNAGE BACKGROUND

COLOR

PT-2 GRAY HARBOR - ACCENT PAINT COLOR

PT-1 RHINESTONE - FIELD PAINT COLOR

PL-1 NEOWALNUT -

BREAK ROOM MILLWORK / GENERAL

WOOD COLOR

PFT-1 MIST 12" X 24"

RESTROOMS (PORCELAIN FLOOR

TILE)

LVT-1 ASH LIMESTONE 12" X 18" 30 MIL WEAR LAYER

EP-1 PLATINUM ESD - -

CPT-1 AVATAR 18" X 36" -

FINISH STYLE COLOR SIZE NOTES

INTERIOR MATERIALS INDEX

NOTE: EPOXY RESIN FLOORING TO BE OPTION LINE ITEM (OLI)

REV DESCRIPTION DATE

1 AMENDMENT 001 JAN 2023

MATERIALS ABBREVIATION LEGEND

EP EPOXY RESIN FINISH

WM WALK-OFF MAT

LVT LUXURY VINYL TILE

CONC CONCRETE

PFT PORCELAIN FLOOR TILE

PWT PORCELAIN WALL TILE

PT PAINT

ESD ELECTRO-STATIC DISSIPATIVE FLOORING

GYP GYPSUM WALL BOARD

CPT CARPET

PL PLASTIC LAMINATE

SS SOLID-SURFACE MATERIAL

APC ACOUSTICAL PANEL CEILING

THESE DOCUMENTS ARE FOR

INTERIM REVIEW AND NOT FOR

CONSTRUCTION, BIDDING, OR

PERMIT PURPOSES.

THESE DOCUMENTS ARE

INTERIM REVIEW AND NO

CONSTRUCTION, BIDDING

PERMIT PURPOSES.

3/31/2201/12/2023 dysonb Highlight

PFT-1