A-130 - A-137 - RCPs_ Amendment 001.pdf

PDF 3 MB Posted

Attached to
Construct Aircraft Support Equipment (ASE) and Vehicle Maintenance (VM) Facility, Bradley Air National Guard Base, CT
Solicitation number
W50SC2-23-R-0001
Issued by

About this file

This solicitation is for the construction of an Aircraft Support Equipment (ASE) and Vehicle Maintenance (VM) Facility at Bradley Air National Guard Base in East Granby, Connecticut. Work includes all labor, materials, equipment, tools, supervision and services necessary to construct the facility in accordance with contract drawings and technical specifications. The project magnitude is estimated between $10-25 million. The North American Industry Classification code is 236220 with a small business size standard of $39.5 million average annual revenue. The solicitation allows for unrestricted competition and contemplates a single award. Offerors must submit a proposal on all items or risk rejection. Funding is not presently available but is expected to be appropriated prior to award, as this project is on the National Guard's priority list. No award will be made until funds are released.

View the file

Other files

File Type Posted
CEKT179200 Geotechnical Report - CTANG - Final.pdf PDF
W50SC2-23-R-0001 Amendment 0002 SF 30.pdf PDF
C-304 - Civil Details_Amendment 002.pdf PDF
122413 - Roller Window Shades_Amendment 002.pdf PDF
104416 FL - Fire Extinguishers_Amendment 002.pdf PDF
FS001_Amendment 002.pdf PDF
W50SC223R0001 RFI Log 20230118.pdf PDF
CTANG ASE-VMXS _ RPF Building Survey Report October 2019_Amendment 002.pdf PDF
024119 FL - Selective Demolition_Amendment 002.pdf PDF
W50SC2-23-R-0001 Amendment 0001 SF 30.pdf PDF
Small Business Participation Plan Form.pdf PDF
329300 - Plants_Amendment 001.pdf PDF
A-610 - Door Schedule_Amendment 001.pdf PDF
101400 - Signage_Amendment 001.pdf PDF
C-304 - Civil Details_Amendment 001.pdf PDF
329113 - Soil Preparation_Amendment 001.pdf PDF
311000 - Site Clearing_Amendment 001.pdf PDF
334200 - Stormwater Conveyance_Amendment 001.pdf PDF
093013 Ceramic Tiling_Amendment 001.pdf PDF
C-306 - Civil Details_Amendment 001.pdf PDF
W50SC223R0001 RFI Log 20230112.pdf PDF
A-601 - Finish Schedule - Amendment 001.pdf PDF
Pre-Proposal Conference Attendance Sheet 20230105.pdf PDF
CE Pre-Proposal Slides.pdf PDF
Contracting Pre-Proposal Slides.pdf PDF
W50SC223R0001 RFI Log 20221228.pdf PDF
W50SC223R0001 RFI Log 20221222.pdf PDF
W50SC223R0001 RFI Log 20221201.pdf PDF
Brand Name JA CEKT179200 signed.pdf PDF
W50SC2-23-R-0001.pdf PDF
Mandatory Signs 2.pdf PDF
Manadatory Door Hardware.pdf PDF
EXHIBIT B - Subcontractor Information and Consent Form.docx DOCX document
EXHIBIT D - Letter of Commitment ok Key Personnel.docx DOCX document
Mandatory Signs 1.pdf PDF
EXHIBIT A - Performance Relevancy Questionnaire.docx DOCX document
Mandatory Sign Part Numbers.pdf PDF
EXHIBIT C - Reference_Questionnaire_Package.docx DOCX document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3 4

A

B

5 6 7 8 9 10

C

K'

J'

H'

G'

F'

E'

D'

C'

B'

A'

1.5

4.5

10.5

3.5

F

E

J

H

G

D

C.2

9.1

9.2

B.6

5.7

111123

ACCESS PANEL

RETURN AIR GRILLE; REFER TO MECHANICAL

SUPPLY AIR DIFFUSER; REFER TO MECHANICAL

RECESSED CAN DOWNLIGHT (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 4' HANGING LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 2' RECESSED LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE; REFER TO ELECTRICAL

STRIP LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING FIXTURES LEGEND

GYPSUM BOARD CEILING

ACOUSTICAL PANEL CEILING (APC) ASSEMBLY

COVERED OUTDOOR SPACE LIGHT FIXTURE (BLACK FILL

INDICATES EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING SPEAKER; REFER TO TELECOM

MANUAL ROLLER SHADE

DUAL BLACKOUT SHADE

LINEAR PENDANT FIXTURE; REFER TO ELECTRICAL

LINEAR LED FIXTURE; REFER TO ELECTRICAL

CEILING MOUNTED SENSORS; REFER TO ELECTRICALOS VSPC

EMERGENCY LIGHTING; REFER TO ELECTRICAL

WALL-MOUNTED LIGHT FIXTURE; REFER TO ELECTRICAL

SECURITY CAMERA; REFER TO TELECOM

EMERGENCY EXIT SIGN; REFER TO ELECTRICAL

FIRE ALARM DEVICE; REFER TO FIRE PROTECTION

GENERAL NOTES

KEYNOTES

1. ALL GYPSUM BOARD AND ACOUSTICAL CEILINGS TO BE 10'-0"

ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED

2. REFER TO PLUMBING, MECHANICAL, ELECTRICAL, FIRE SUPPRESSION, FIRE

ALARM, AND TELECOMMUNICATION DRAWINGS FOR ALL VENTS, SPRINKLER

HEADS, GRILLES, REGISTERS, DIFFUSERS, DUCTS, LIGHT FIXTURES,

DETECTORS, ETC.; COORDINATE THESE ITEMS AS REQUIRED.

3. COORDINATE ALL STRUCTURAL, PLUMBING, MECHANICAL, FIRE

SUPPRESSION, AND ELECTRICAL WORK WITH CEILING HEIGHTS AND

ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR, COORDINATE FINAL

LOCATIONS WITH COR.

4. REFER TO ROOM FINISH SCHEDULE FOR CEILING MATERIALS, FINISHES, AND

HEIGHTS.

5. ALL CEILING-MOUNTED OR RECESSED ITEMS SHOWN - OR NOT - ON

REFLECTED CEILING PLANS (SUCH AS SPRINKLER HEADS, SPEAKERS,

SPEAKER STROBES, GRILLES, LIGHTS, ETC.) SHALL BE CENTERED IN THE LAY-

IN ACT PANELS. AT GYPSUM BOARD CEILINGS, INSTALL IN A CONSISTENT

PATTERN. LOCATE SPRINKLER HEADS IN CONSISTENT PATTERN AS

INDICATED. CEILING MOUNTED ELEMENTS DIMENSIONED TO CENTERLINES

UNLESS OTHERWISE NOTED.

6. NOTIFY COR OF ALL ITEMS NOT SHOWN ON REFLECTED CEILING PLAN AND

LOCATE PER COR DIRECTION.

7. REFER TO TELECOMMUNICATION DRAWINGS FOR CAMERA LOCATIONS.

8. REFER TO DETAILS FOR MECHANICAL, ELECTRICAL, AND PLUMBING ACCESS

PANELS IN A GYPSUM BOARD CEILING.

9. GRID LAYOUT AND LOCATIONS OF LIGHT FIXTURES AND DIFFUSERS ON THE

REFLECTED CEILING PLANS GOVERN OVER ELECTRICAL AND MECHANICAL

DRAWINGS.

10. REFER TO SPECIAL SYSTEMS DRAWINGS FOR SPEAKER TYPES & SIZES,

CAMERA TYPES & SIZES, ETC.

11. ALL CEILING PENETRATIONS SHALL BE TREATED AS PERIMETER CLOSURES

AND SHALL ALLOW A MINIMUM OF 3/8" CLEARANCE BY USE OF SUITABLE

ESCUTCHEONS OR CLOSURE DETAILS.

12. REFER TO A-510 FOR CEILING TRANSITION DETAILS.

N

8' 16' 32'

1/16" = 1'-0"

48'0

A

Designed:

Drawn:

Checked:

Date:

Drawing Title:

Jacobs Project No.:

Key Plan:

D3257200

B

C

D

2 3 4 5

Scales:

THESE DOCUMENTS ARE FOR

INTERIM REVIEW AND NOT FOR

CONSTRUCTION, BIDDING, OR

PERMIT PURPOSES.

Phase: B-3 FINAL DESIGN

C O

N N

E C

T

IC

U T

A

IR

N A

T

IO

N A

L G

U A

R D

R

D A

IR

L

IF

T

W

IN

G

B R

A D

L E

Y A

IR

N

A T

IO

N

L

G

U A

R D

B A

S E

E A

S T

G R

A N

B Y

C

O N

N E

C T

IC

U

T

C O

M P

O S

IT

E

A S

E A

N D

V

M X

S F

A C

IL

IT

Y

Drawing No.:

C

D

A E

S

B

ARCHITECTURAL

B

IM

/U

S C

T D

C

A N

G A

S E

-V M

X S

F a c ili ty /D

C

T A

N G

A

S E

-V M

X S

F A

C

IL

IT

Y

A

R C

H .r v t

/1

/2

:1

:0

P

M

B. HENDON

J. McKINNEY

J. PERRY

03/31/2022

A-130

OVERALL REFLECTED

CEILING PLAN -

ASE/VMXS FACILITY

1/16" = 1'-0"A1

OVERALL REFLECTED CEILING PLAN

111 METAL PANEL-WRAPPED HSS TUBE STEEL TRELLIS STRUCTURE AT OUTDOOR

BREAK AREA; REFER TO STRUCTURAL

123 SHEET METAL FASCIA AND SOFFIT PANELS FORMED BY INSULATED PANEL

MANUFACTURER, TYP.

REV DESCRIPTION DATE

1 AMENDMENT 001 JAN 2023

THESE DOCUMENTS ARE

INTERIM REVIEW AND NO

CONSTRUCTION, BIDDING

PERMIT PURPOSES.

3/31/2201/12/2023

K'

J'

H'

1.5

4.5

MATCHLINE

SEE SHEET A-132

MATCHLINE

SEE SHEET A-132

14' - 0"

14' - 0"

2" / 12"

2" / 12"

126126

ACCESS PANEL

RETURN AIR GRILLE; REFER TO MECHANICAL

SUPPLY AIR DIFFUSER; REFER TO MECHANICAL

RECESSED CAN DOWNLIGHT (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 4' HANGING LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 2' RECESSED LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE; REFER TO ELECTRICAL

STRIP LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING FIXTURES LEGEND

GYPSUM BOARD CEILING

ACOUSTICAL PANEL CEILING (APC) ASSEMBLY

COVERED OUTDOOR SPACE LIGHT FIXTURE (BLACK FILL

INDICATES EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING SPEAKER; REFER TO TELECOM

MANUAL ROLLER SHADE

DUAL BLACKOUT SHADE

LINEAR PENDANT FIXTURE; REFER TO ELECTRICAL

LINEAR LED FIXTURE; REFER TO ELECTRICAL

CEILING MOUNTED SENSORS; REFER TO ELECTRICALOS VSPC

EMERGENCY LIGHTING; REFER TO ELECTRICAL

WALL-MOUNTED LIGHT FIXTURE; REFER TO ELECTRICAL

SECURITY CAMERA; REFER TO TELECOM

EMERGENCY EXIT SIGN; REFER TO ELECTRICAL

FIRE ALARM DEVICE; REFER TO FIRE PROTECTION

GENERAL NOTES

KEYNOTES

1. ALL GYPSUM BOARD AND ACOUSTICAL CEILINGS TO BE 10'-0"

ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED

2. REFER TO PLUMBING, MECHANICAL, ELECTRICAL, FIRE SUPPRESSION, FIRE

ALARM, AND TELECOMMUNICATION DRAWINGS FOR ALL VENTS, SPRINKLER

HEADS, GRILLES, REGISTERS, DIFFUSERS, DUCTS, LIGHT FIXTURES,

DETECTORS, ETC.; COORDINATE THESE ITEMS AS REQUIRED.

3. COORDINATE ALL STRUCTURAL, PLUMBING, MECHANICAL, FIRE

SUPPRESSION, AND ELECTRICAL WORK WITH CEILING HEIGHTS AND

ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR, COORDINATE FINAL

LOCATIONS WITH COR.

4. REFER TO ROOM FINISH SCHEDULE FOR CEILING MATERIALS, FINISHES, AND

HEIGHTS.

5. ALL CEILING-MOUNTED OR RECESSED ITEMS SHOWN - OR NOT - ON

REFLECTED CEILING PLANS (SUCH AS SPRINKLER HEADS, SPEAKERS,

SPEAKER STROBES, GRILLES, LIGHTS, ETC.) SHALL BE CENTERED IN THE LAY-

IN ACT PANELS. AT GYPSUM BOARD CEILINGS, INSTALL IN A CONSISTENT

PATTERN. LOCATE SPRINKLER HEADS IN CONSISTENT PATTERN AS

INDICATED. CEILING MOUNTED ELEMENTS DIMENSIONED TO CENTERLINES

UNLESS OTHERWISE NOTED.

6. NOTIFY COR OF ALL ITEMS NOT SHOWN ON REFLECTED CEILING PLAN AND

LOCATE PER COR DIRECTION.

7. REFER TO TELECOMMUNICATION DRAWINGS FOR CAMERA LOCATIONS.

8. REFER TO DETAILS FOR MECHANICAL, ELECTRICAL, AND PLUMBING ACCESS

PANELS IN A GYPSUM BOARD CEILING.

9. GRID LAYOUT AND LOCATIONS OF LIGHT FIXTURES AND DIFFUSERS ON THE

REFLECTED CEILING PLANS GOVERN OVER ELECTRICAL AND MECHANICAL

DRAWINGS.

10. REFER TO SPECIAL SYSTEMS DRAWINGS FOR SPEAKER TYPES & SIZES,

CAMERA TYPES & SIZES, ETC.

11. ALL CEILING PENETRATIONS SHALL BE TREATED AS PERIMETER CLOSURES

AND SHALL ALLOW A MINIMUM OF 3/8" CLEARANCE BY USE OF SUITABLE

ESCUTCHEONS OR CLOSURE DETAILS.

12. REFER TO A-510 FOR CEILING TRANSITION DETAILS.

N

4' 8' 16'

1/8" = 1'-0"

24'0

A

Designed:

Drawn:

Checked:

Date:

Drawing Title:

Jacobs Project No.:

Key Plan:

D3257200

B

C

D

2 3 4 5

Scales:

THESE DOCUMENTS ARE FOR

INTERIM REVIEW AND NOT FOR

CONSTRUCTION, BIDDING, OR

PERMIT PURPOSES.

Phase: B-3 FINAL DESIGN

C O

N N

E C

T

IC

U T

A

IR

N A

T

IO

N A

L G

U A

R D

R

D A

IR

L

IF

T

W

IN

G

B R

A D

L E

Y A

IR

N

A T

IO

N

A

R D

B A

S E

E A

S T

G R

A N

B Y

C

O N

N E

C T

IC

U

T

C O

M P

O S

IT

E

A S

E A

X

S F

A C

IL

IT

Y

Drawing No.:

C

D

A E

S

B

ARCHITECTURAL

B

IM

/U

S C

T D

C

A N

G A

S E

-V M

X S

F a c ili ty /D

C

T A

N G

A

S E

-V M

X S

F A

C

IL

IT

Y

A

R C

H .r v t

/1

/2

:1

:0

P

M

B. HENDON

J. McKINNEY

J. PERRY

03/31/2022

A-131

PARTIAL RCP -

ASE/VMXS FACILITY -

AREA A

1/8" = 1'-0"

A-200

A1

PARTIAL REFLECTED CEILING PLAN - ASE/VMXS FACILITY - AREA A

A-130

113 6"x6" CONTINUOUS SHEET METAL GUTTER, TYP.

123 SHEET METAL FASCIA AND SOFFIT PANELS FORMED BY INSULATED PANEL

MANUFACTURER, TYP.

126 EXPOSED STEEL SUPERSTRUCTURE AND ROOF DECK - PAINTED, TYP.

278 HANGING FAN; REFER TO MECHANICAL AND STRUCTURAL

REV DESCRIPTION DATE

1 AMENDMENT 001 JAN 2023

THESE DOCUMENTS ARE

INTERIM REVIEW AND NO

CONSTRUCTION, BIDDING

T75

PC

PC

OS

2 3 4 5

H'

G'

F'

E'

D'

C'

B'

1.5

4.53.5

MATCHLINE

SEE SHEET A-131

MATCHLINE

SEE SHEET A-133

MATCHLINE

SEE SHEET A-133

MATCHLINE

SEE SHEET A-131

123123

7' - 8"

12' - 0"

16' - 4"

12' - 0"

9' - 0"

B3

A-510

GENERAL NOTES

KEYNOTES

1. ALL GYPSUM BOARD AND ACOUSTICAL CEILINGS TO BE 10'-0"

ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED

2. REFER TO PLUMBING, MECHANICAL, ELECTRICAL, FIRE SUPPRESSION, FIRE

ALARM, AND TELECOMMUNICATION DRAWINGS FOR ALL VENTS, SPRINKLER

HEADS, GRILLES, REGISTERS, DIFFUSERS, DUCTS, LIGHT FIXTURES,

DETECTORS, ETC.; COORDINATE THESE ITEMS AS REQUIRED.

3. COORDINATE ALL STRUCTURAL, PLUMBING, MECHANICAL, FIRE

SUPPRESSION, AND ELECTRICAL WORK WITH CEILING HEIGHTS AND

ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR, COORDINATE FINAL

LOCATIONS WITH COR.

4. REFER TO ROOM FINISH SCHEDULE FOR CEILING MATERIALS, FINISHES, AND

HEIGHTS.

5. ALL CEILING-MOUNTED OR RECESSED ITEMS SHOWN - OR NOT - ON

REFLECTED CEILING PLANS (SUCH AS SPRINKLER HEADS, SPEAKERS,

SPEAKER STROBES, GRILLES, LIGHTS, ETC.) SHALL BE CENTERED IN THE LAY-

IN ACT PANELS. AT GYPSUM BOARD CEILINGS, INSTALL IN A CONSISTENT

PATTERN. LOCATE SPRINKLER HEADS IN CONSISTENT PATTERN AS

INDICATED. CEILING MOUNTED ELEMENTS DIMENSIONED TO CENTERLINES

UNLESS OTHERWISE NOTED.

6. NOTIFY COR OF ALL ITEMS NOT SHOWN ON REFLECTED CEILING PLAN AND

LOCATE PER COR DIRECTION.

7. REFER TO TELECOMMUNICATION DRAWINGS FOR CAMERA LOCATIONS.

8. REFER TO DETAILS FOR MECHANICAL, ELECTRICAL, AND PLUMBING ACCESS

PANELS IN A GYPSUM BOARD CEILING.

9. GRID LAYOUT AND LOCATIONS OF LIGHT FIXTURES AND DIFFUSERS ON THE

REFLECTED CEILING PLANS GOVERN OVER ELECTRICAL AND MECHANICAL

DRAWINGS.

10. REFER TO SPECIAL SYSTEMS DRAWINGS FOR SPEAKER TYPES & SIZES,

CAMERA TYPES & SIZES, ETC.

11. ALL CEILING PENETRATIONS SHALL BE TREATED AS PERIMETER CLOSURES

AND SHALL ALLOW A MINIMUM OF 3/8" CLEARANCE BY USE OF SUITABLE

ESCUTCHEONS OR CLOSURE DETAILS.

12. REFER TO A-510 FOR CEILING TRANSITION DETAILS.

ACCESS PANEL

RETURN AIR GRILLE; REFER TO MECHANICAL

SUPPLY AIR DIFFUSER; REFER TO MECHANICAL

RECESSED CAN DOWNLIGHT (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 4' HANGING LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 2' RECESSED LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE; REFER TO ELECTRICAL

STRIP LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING FIXTURES LEGEND

GYPSUM BOARD CEILING

ACOUSTICAL PANEL CEILING (APC) ASSEMBLY

COVERED OUTDOOR SPACE LIGHT FIXTURE (BLACK FILL

INDICATES EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING SPEAKER; REFER TO TELECOM

MANUAL ROLLER SHADE

DUAL BLACKOUT SHADE

LINEAR PENDANT FIXTURE; REFER TO ELECTRICAL

LINEAR LED FIXTURE; REFER TO ELECTRICAL

CEILING MOUNTED SENSORS; REFER TO ELECTRICALOS VSPC

EMERGENCY LIGHTING; REFER TO ELECTRICAL

WALL-MOUNTED LIGHT FIXTURE; REFER TO ELECTRICAL

SECURITY CAMERA; REFER TO TELECOM

EMERGENCY EXIT SIGN; REFER TO ELECTRICAL

FIRE ALARM DEVICE; REFER TO FIRE PROTECTION

N

4' 8' 16'

1/8" = 1'-0"

24'0

A

Designed:

Drawn:

Checked:

Date:

Drawing Title:

Jacobs Project No.:

Key Plan:

D3257200

B

C

D

2 3 4 5

Scales:

THESE DOCUMENTS ARE FOR

INTERIM REVIEW AND NOT FOR

CONSTRUCTION, BIDDING, OR

PERMIT PURPOSES.

Phase: B-3 FINAL DESIGN

C O

N N

E C

T

IC

U T

A

IR

N A

T

IO

N A

L G

U A

R D

R

D A

IR

L

IF

T

W

IN

G

B R

A D

L E

Y A

IR

N

A T

IO

N

A

R D

B A

S E

E A

S T

G R

A N

B Y

C

O N

N E

C T

IC

U

T

C O

M P

O S

IT

E

A S

E A

X

S F

A C

IL

IT

Y

Drawing No.:

C

D

A E

S

B

ARCHITECTURAL

B

IM

/U

S C

T D

C

A N

G A

S E

-V M

X S

F a c ili ty /D

C

T A

N G

A

S E

-V M

X S

F A

C

IL

IT

Y

A

R C

H .r v t

/1

/2

:1

:0

P

M

B. HENDON

J. McKINNEY

J. PERRY

03/31/2022

A-132

PARTIAL RCP -

ASE/VMXS FACILITY -

AREA B

1/8" = 1'-0"

A-200

A1

PARTIAL REFLECTED CEILING PLAN - ASE/VMXS FACILITY - AREA B

A-130

113 6"x6" CONTINUOUS SHEET METAL GUTTER, TYP.

117 MECHANICAL EQUIPMENT; REFER TO MECHANICAL

120 5-TON BRIDGE CRANE; REFER TO STRUCTURE FOR STEEL SUPPORT FRAMING.

REFER TO EQUIPMENT DRAWINGS.

123 SHEET METAL FASCIA AND SOFFIT PANELS FORMED BY INSULATED PANEL

MANUFACTURER, TYP.

272 VEHICLE EXHAUST SYSTEM; REFER TO MECHANICAL

278 HANGING FAN; REFER TO MECHANICAL AND STRUCTURAL

REV DESCRIPTION DATE

1 AMENDMENT 001 JAN 2023

THESE DOCUMENTS ARE

INTERIM REVIEW AND NO

CONSTRUCTION, BIDDING

OS

OSOSOS

OS

VS

VS

VS

VS

VS VS

VS VS VS

VS VS

OSOSOSOSOS

OS

OS

VS

OS

T75

PC

PC PC PC PC

PC PC PC

OS

OS

VS

VS

1 2 3 4

A

B

5 6 7 8 9

C

B'

A'

1.5

3.5

MATCHLINE

SEE SHEET A-132

M A

T C

H L

IN

E

S E

E S

H E

E T

A -1

C.2

9.1

B.6

5.7

14'-0"

14'-0"

11'-0"

9'-0"

8'-0"

12'-0"

9'-0"

9'-0"

9'-0"

9'-0"

7'-4"

9'-0"

9'-0"

123123

123123

111111

123 113

A3

A-510

B3

A-511

PT-3

6'-0"

PT-3

MATCHLINE

SEE SHEET A-132

5' - 1" 3' - 0"

2' - 0"

3' - 0"

1' - 10" 1' - 6"

2' - 1"

2' - 1"

1' - 2"

1' - 0"

7' - 8" 1

EQ

5' - 1"

EQ

E Q

E Q

EQ EQ

EQ EQ

EQ EQ

E Q

E Q

9' - 0"

E Q

E Q

/2

5" 4' - 0" 4' - 0"

2' - 0"

1' - 8"

1' - 9"

2' - 7"

EQEQ

1' - 8" 1' - 6"

EQ

EQ

2' - 7" 1' - 9"

1' - 5" 1' - 10" 2' - 7"

3' - 2"

3' - 0"

1' - 10" 2' - 2" 2' - 0"

B3

A-510

GENERAL NOTES

KEYNOTES

1. ALL GYPSUM BOARD AND ACOUSTICAL CEILINGS TO BE 10'-0"

ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED

2. REFER TO PLUMBING, MECHANICAL, ELECTRICAL, FIRE SUPPRESSION, FIRE

ALARM, AND TELECOMMUNICATION DRAWINGS FOR ALL VENTS, SPRINKLER

HEADS, GRILLES, REGISTERS, DIFFUSERS, DUCTS, LIGHT FIXTURES,

DETECTORS, ETC.; COORDINATE THESE ITEMS AS REQUIRED.

3. COORDINATE ALL STRUCTURAL, PLUMBING, MECHANICAL, FIRE

SUPPRESSION, AND ELECTRICAL WORK WITH CEILING HEIGHTS AND

ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR, COORDINATE FINAL

LOCATIONS WITH COR.

4. REFER TO ROOM FINISH SCHEDULE FOR CEILING MATERIALS, FINISHES, AND

HEIGHTS.

5. ALL CEILING-MOUNTED OR RECESSED ITEMS SHOWN - OR NOT - ON

REFLECTED CEILING PLANS (SUCH AS SPRINKLER HEADS, SPEAKERS,

SPEAKER STROBES, GRILLES, LIGHTS, ETC.) SHALL BE CENTERED IN THE LAY-

IN ACT PANELS. AT GYPSUM BOARD CEILINGS, INSTALL IN A CONSISTENT

PATTERN. LOCATE SPRINKLER HEADS IN CONSISTENT PATTERN AS

INDICATED. CEILING MOUNTED ELEMENTS DIMENSIONED TO CENTERLINES

UNLESS OTHERWISE NOTED.

6. NOTIFY COR OF ALL ITEMS NOT SHOWN ON REFLECTED CEILING PLAN AND

LOCATE PER COR DIRECTION.

7. REFER TO TELECOMMUNICATION DRAWINGS FOR CAMERA LOCATIONS.

8. REFER TO DETAILS FOR MECHANICAL, ELECTRICAL, AND PLUMBING ACCESS

PANELS IN A GYPSUM BOARD CEILING.

9. GRID LAYOUT AND LOCATIONS OF LIGHT FIXTURES AND DIFFUSERS ON THE

REFLECTED CEILING PLANS GOVERN OVER ELECTRICAL AND MECHANICAL

DRAWINGS.

10. REFER TO SPECIAL SYSTEMS DRAWINGS FOR SPEAKER TYPES & SIZES,

CAMERA TYPES & SIZES, ETC.

11. ALL CEILING PENETRATIONS SHALL BE TREATED AS PERIMETER CLOSURES

AND SHALL ALLOW A MINIMUM OF 3/8" CLEARANCE BY USE OF SUITABLE

ESCUTCHEONS OR CLOSURE DETAILS.

12. REFER TO A-510 FOR CEILING TRANSITION DETAILS.

ACCESS PANEL

RETURN AIR GRILLE; REFER TO MECHANICAL

SUPPLY AIR DIFFUSER; REFER TO MECHANICAL

RECESSED CAN DOWNLIGHT (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 4' HANGING LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 2' RECESSED LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE; REFER TO ELECTRICAL

STRIP LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING FIXTURES LEGEND

GYPSUM BOARD CEILING

ACOUSTICAL PANEL CEILING (APC) ASSEMBLY

COVERED OUTDOOR SPACE LIGHT FIXTURE (BLACK FILL

INDICATES EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING SPEAKER; REFER TO TELECOM

MANUAL ROLLER SHADE

DUAL BLACKOUT SHADE

LINEAR PENDANT FIXTURE; REFER TO ELECTRICAL

LINEAR LED FIXTURE; REFER TO ELECTRICAL

CEILING MOUNTED SENSORS; REFER TO ELECTRICALOS VSPC

EMERGENCY LIGHTING; REFER TO ELECTRICAL

WALL-MOUNTED LIGHT FIXTURE; REFER TO ELECTRICAL

SECURITY CAMERA; REFER TO TELECOM

EMERGENCY EXIT SIGN; REFER TO ELECTRICAL

FIRE ALARM DEVICE; REFER TO FIRE PROTECTION

N

4' 8' 16'

1/8" = 1'-0"

24'0

A

Designed:

Drawn:

Checked:

Date:

Drawing Title:

Jacobs Project No.:

Key Plan:

D3257200

B

C

D

2 3 4 5

Scales:

THESE DOCUMENTS ARE FOR

INTERIM REVIEW AND NOT FOR

CONSTRUCTION, BIDDING, OR

PERMIT PURPOSES.

Phase: B-3 FINAL DESIGN

C O

N N

E C

T

IC

U T

A

IR

N A

T

IO

N A

L G

U A

R D

R

D A

IR

L

IF

T

W

IN

G

B R

A D

L E

Y A

IR

N

A T

IO

N

A

R D

B A

S E

E A

S T

G R

A N

B Y

C

O N

N E

C T

IC

U

T

C O

M P

O S

IT

E

A S

E A

X

S F

A C

IL

IT

Y

Drawing No.:

C

D

A E

S

B

ARCHITECTURAL

B

IM

/U

S C

T D

C

A N

G A

S E

-V M

X S

F a c ili ty /D

C

T A

N G

A

S E

-V M

X S

F A

C

IL

IT

Y

A

R C

H .r v t

/1

/2

:1

:0

P

M

B. HENDON

J. McKINNEY

J. PERRY

03/31/2022

A-133

PARTIAL RCP -

ASE/VMXS FACILITY -

AREA C

1/8" = 1'-0"

A-200

A1

PARTIAL REFLECTED CEILING PLAN - ASE/VMXS FACILITY - AREA C

A-130

111 METAL PANEL-WRAPPED HSS TUBE STEEL TRELLIS STRUCTURE AT OUTDOOR

BREAK AREA; REFER TO STRUCTURAL

113 6"x6" CONTINUOUS SHEET METAL GUTTER, TYP.

123 SHEET METAL FASCIA AND SOFFIT PANELS FORMED BY INSULATED PANEL

MANUFACTURER, TYP.

199 OPERABLE PARTITION; REFER TO A-510 FOR DETAILS. COORDINATE WITH

STRUCTURAL TO HANG PARTITION TRACK FROM STRUCTURAL FRAMING.

PT-3 PAINT COLOR 3; REFER TO INTERIOR MATERIALS INDEX FOR BASIS OF DESIGN

REV DESCRIPTION DATE

1 AMENDMENT 001 JAN 2023

THESE DOCUMENTS ARE

INTERIM REVIEW AND NO

CONSTRUCTION, BIDDING

VS

VS

OSOS

O S

A

B

C

10.5

M A

T C

H L

IN

E

S E

E S

H E

E T

A -1

MATCHLINE

SEE SHEET A-135

F

E

G

D

C.2

9.1 9.2

12'-0"

9'-0"

123123

MATCHLINE

SEE SHEET A-135

EQ EQ

E Q

E Q

12' - 0" 16' - 0" 12' - 0"

"2' - 0"

117117

4' - 0" 6' - 4" 4' - 0"

3' - 8"

3' - 8"

126126

12' - 0" 16' - 0" 12' - 0"

GENERAL NOTES

KEYNOTES

1. ALL GYPSUM BOARD AND ACOUSTICAL CEILINGS TO BE 10'-0"

ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED

2. REFER TO PLUMBING, MECHANICAL, ELECTRICAL, FIRE SUPPRESSION, FIRE

ALARM, AND TELECOMMUNICATION DRAWINGS FOR ALL VENTS, SPRINKLER

HEADS, GRILLES, REGISTERS, DIFFUSERS, DUCTS, LIGHT FIXTURES,

DETECTORS, ETC.; COORDINATE THESE ITEMS AS REQUIRED.

3. COORDINATE ALL STRUCTURAL, PLUMBING, MECHANICAL, FIRE

SUPPRESSION, AND ELECTRICAL WORK WITH CEILING HEIGHTS AND

ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR, COORDINATE FINAL

LOCATIONS WITH COR.

4. REFER TO ROOM FINISH SCHEDULE FOR CEILING MATERIALS, FINISHES, AND

HEIGHTS.

5. ALL CEILING-MOUNTED OR RECESSED ITEMS SHOWN - OR NOT - ON

REFLECTED CEILING PLANS (SUCH AS SPRINKLER HEADS, SPEAKERS,

SPEAKER STROBES, GRILLES, LIGHTS, ETC.) SHALL BE CENTERED IN THE LAY-

IN ACT PANELS. AT GYPSUM BOARD CEILINGS, INSTALL IN A CONSISTENT

PATTERN. LOCATE SPRINKLER HEADS IN CONSISTENT PATTERN AS

INDICATED. CEILING MOUNTED ELEMENTS DIMENSIONED TO CENTERLINES

UNLESS OTHERWISE NOTED.

6. NOTIFY COR OF ALL ITEMS NOT SHOWN ON REFLECTED CEILING PLAN AND

LOCATE PER COR DIRECTION.

7. REFER TO TELECOMMUNICATION DRAWINGS FOR CAMERA LOCATIONS.

8. REFER TO DETAILS FOR MECHANICAL, ELECTRICAL, AND PLUMBING ACCESS

PANELS IN A GYPSUM BOARD CEILING.

9. GRID LAYOUT AND LOCATIONS OF LIGHT FIXTURES AND DIFFUSERS ON THE

REFLECTED CEILING PLANS GOVERN OVER ELECTRICAL AND MECHANICAL

DRAWINGS.

10. REFER TO SPECIAL SYSTEMS DRAWINGS FOR SPEAKER TYPES & SIZES,

CAMERA TYPES & SIZES, ETC.

11. ALL CEILING PENETRATIONS SHALL BE TREATED AS PERIMETER CLOSURES

AND SHALL ALLOW A MINIMUM OF 3/8" CLEARANCE BY USE OF SUITABLE

ESCUTCHEONS OR CLOSURE DETAILS.

12. REFER TO A-510 FOR CEILING TRANSITION DETAILS.

ACCESS PANEL

RETURN AIR GRILLE; REFER TO MECHANICAL

SUPPLY AIR DIFFUSER; REFER TO MECHANICAL

RECESSED CAN DOWNLIGHT (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 4' HANGING LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 2' RECESSED LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE; REFER TO ELECTRICAL

STRIP LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING FIXTURES LEGEND

GYPSUM BOARD CEILING

ACOUSTICAL PANEL CEILING (APC) ASSEMBLY

COVERED OUTDOOR SPACE LIGHT FIXTURE (BLACK FILL

INDICATES EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING SPEAKER; REFER TO TELECOM

MANUAL ROLLER SHADE

DUAL BLACKOUT SHADE

LINEAR PENDANT FIXTURE; REFER TO ELECTRICAL

LINEAR LED FIXTURE; REFER TO ELECTRICAL

CEILING MOUNTED SENSORS; REFER TO ELECTRICALOS VSPC

EMERGENCY LIGHTING; REFER TO ELECTRICAL

WALL-MOUNTED LIGHT FIXTURE; REFER TO ELECTRICAL

SECURITY CAMERA; REFER TO TELECOM

EMERGENCY EXIT SIGN; REFER TO ELECTRICAL

FIRE ALARM DEVICE; REFER TO FIRE PROTECTION

N

4' 8' 16'

1/8" = 1'-0"

24'0

A

Designed:

Drawn:

Checked:

Date:

Drawing Title:

Jacobs Project No.:

Key Plan:

D3257200

B

C

D

2 3 4 5

Scales:

THESE DOCUMENTS ARE FOR

INTERIM REVIEW AND NOT FOR

CONSTRUCTION, BIDDING, OR

PERMIT PURPOSES.

Phase: B-3 FINAL DESIGN

C O

N N

E C

T

IC

U T

A

IR

N A

T

IO

N A

L G

U A

R D

R

D A

IR

L

IF

T

W

IN

G

B R

A D

L E

Y A

IR

N

A T

IO

N

A

R D

B A

S E

E A

S T

G R

A N

B Y

C

O N

N E

C T

IC

U

T

C O

M P

O S

IT

E

A S

E A

X

S F

A C

IL

IT

Y

Drawing No.:

C

D

A E

S

B

ARCHITECTURAL

B

IM

/U

S C

T D

C

A N

G A

S E

-V M

X S

F a c ili ty /D

C

T A

N G

A

S E

-V M

X S

F A

C

IL

IT

Y

A

R C

H .r v t

/1

/2

:1

:1

P

M

B. HENDON

J. McKINNEY

J. PERRY

03/31/2022

A-134

PARTIAL RCP -

ASE/VMXS FACILITY -

AREA D

1/8" = 1'-0"

A-200

A1

PARTIAL REFLECTED CEILING PLAN - ASE/VMXS FACILITY - AREA D

A-130

103 VINYL COVERED CHAIN-LINK ENCLOSURE WITH GATE; REFER TO A-545 FOR

CHAIN LINK ENCLOSURE DETAILS

108 STAINLESS STEEL ROOF ACCESS LADDER WITH OSHA COMPLIANT RAIL &

HARNESS FALL ARREST SYSTEM AS SPECIFIED; REFER TO SHEET A-541 & A-542

113 6"x6" CONTINUOUS SHEET METAL GUTTER, TYP.

117 MECHANICAL EQUIPMENT; REFER TO MECHANICAL

121 OLI - 3-TON BRIDGE CRANE; REFER TO STRUCTURE FOR STEEL SUPPORT

FRAMING. REFER TO EQUIPMENT DRAWINGS.

123 SHEET METAL FASCIA AND SOFFIT PANELS FORMED BY INSULATED PANEL

MANUFACTURER, TYP.

126 EXPOSED STEEL SUPERSTRUCTURE AND ROOF DECK - PAINTED, TYP.

272 VEHICLE EXHAUST SYSTEM; REFER TO MECHANICAL

276 FALL PROTECTION SUPPORT; REFER TO STRUCTURAL

278 HANGING FAN; REFER TO MECHANICAL AND STRUCTURAL

314 FALL ARREST SYSTEM TRACK; REFER TO STRUCTURAL AND EQUIPMENT FOR

ADDITIONAL INFORMATION

315 UNIT HEATER; REFER TO MECHANICAL

REV DESCRIPTION DATE

1 AMENDMENT 001 JAN 2023

THESE DOCUMENTS ARE

INTERIM REVIEW AND NO

CONSTRUCTION, BIDDING

PC

10 10.5

J

H

G

9.1

MATCHLINE

SEE SHEET A-134

MATCHLINE

SEE SHEET A-134

314314 117

126126

117117

5' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 5' - 0"

10' - 0" 10' - 0" 10' - 0" 10' - 0" 5' - 0"

5' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 5' - 0"

REFUELING

VEHICLE

SHOP

WASH

RACK

GENERAL NOTES

KEYNOTES

1. ALL GYPSUM BOARD AND ACOUSTICAL CEILINGS TO BE 10'-0"

ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED

2. REFER TO PLUMBING, MECHANICAL, ELECTRICAL, FIRE SUPPRESSION, FIRE

ALARM, AND TELECOMMUNICATION DRAWINGS FOR ALL VENTS, SPRINKLER

HEADS, GRILLES, REGISTERS, DIFFUSERS, DUCTS, LIGHT FIXTURES,

DETECTORS, ETC.; COORDINATE THESE ITEMS AS REQUIRED.

3. COORDINATE ALL STRUCTURAL, PLUMBING, MECHANICAL, FIRE

SUPPRESSION, AND ELECTRICAL WORK WITH CEILING HEIGHTS AND

ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR, COORDINATE FINAL

LOCATIONS WITH COR.

4. REFER TO ROOM FINISH SCHEDULE FOR CEILING MATERIALS, FINISHES, AND

HEIGHTS.

5. ALL CEILING-MOUNTED OR RECESSED ITEMS SHOWN - OR NOT - ON

REFLECTED CEILING PLANS (SUCH AS SPRINKLER HEADS, SPEAKERS,

SPEAKER STROBES, GRILLES, LIGHTS, ETC.) SHALL BE CENTERED IN THE LAY-

IN ACT PANELS. AT GYPSUM BOARD CEILINGS, INSTALL IN A CONSISTENT

PATTERN. LOCATE SPRINKLER HEADS IN CONSISTENT PATTERN AS

INDICATED. CEILING MOUNTED ELEMENTS DIMENSIONED TO CENTERLINES

UNLESS OTHERWISE NOTED.

6. NOTIFY COR OF ALL ITEMS NOT SHOWN ON REFLECTED CEILING PLAN AND

LOCATE PER COR DIRECTION.

7. REFER TO TELECOMMUNICATION DRAWINGS FOR CAMERA LOCATIONS.

8. REFER TO DETAILS FOR MECHANICAL, ELECTRICAL, AND PLUMBING ACCESS

PANELS IN A GYPSUM BOARD CEILING.

9. GRID LAYOUT AND LOCATIONS OF LIGHT FIXTURES AND DIFFUSERS ON THE

REFLECTED CEILING PLANS GOVERN OVER ELECTRICAL AND MECHANICAL

DRAWINGS.

10. REFER TO SPECIAL SYSTEMS DRAWINGS FOR SPEAKER TYPES & SIZES,

CAMERA TYPES & SIZES, ETC.

11. ALL CEILING PENETRATIONS SHALL BE TREATED AS PERIMETER CLOSURES

AND SHALL ALLOW A MINIMUM OF 3/8" CLEARANCE BY USE OF SUITABLE

ESCUTCHEONS OR CLOSURE DETAILS.

12. REFER TO A-510 FOR CEILING TRANSITION DETAILS.

ACCESS PANEL

RETURN AIR GRILLE; REFER TO MECHANICAL

SUPPLY AIR DIFFUSER; REFER TO MECHANICAL

RECESSED CAN DOWNLIGHT (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 4' HANGING LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 2' RECESSED LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE; REFER TO ELECTRICAL

STRIP LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING FIXTURES LEGEND

GYPSUM BOARD CEILING

ACOUSTICAL PANEL CEILING (APC) ASSEMBLY

COVERED OUTDOOR SPACE LIGHT FIXTURE (BLACK FILL

INDICATES EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING SPEAKER; REFER TO TELECOM

MANUAL ROLLER SHADE

DUAL BLACKOUT SHADE

LINEAR PENDANT FIXTURE; REFER TO ELECTRICAL

LINEAR LED FIXTURE; REFER TO ELECTRICAL

CEILING MOUNTED SENSORS; REFER TO ELECTRICALOS VSPC

EMERGENCY LIGHTING; REFER TO ELECTRICAL

WALL-MOUNTED LIGHT FIXTURE; REFER TO ELECTRICAL

SECURITY CAMERA; REFER TO TELECOM

EMERGENCY EXIT SIGN; REFER TO ELECTRICAL

FIRE ALARM DEVICE; REFER TO FIRE PROTECTION

N

4' 8' 16'

1/8" = 1'-0"

24'0

A

Designed:

Drawn:

Checked:

Date:

Drawing Title:

Jacobs Project No.:

Key Plan:

D3257200

B

C

D

2 3 4 5

Scales:

THESE DOCUMENTS ARE FOR

INTERIM REVIEW AND NOT FOR

CONSTRUCTION, BIDDING, OR

PERMIT PURPOSES.

Phase: B-3 FINAL DESIGN

C O

N N

E C

T

IC

U T

A

IR

N A

T

IO

N A

L G

U A

R D

R

D A

IR

L

IF

T

W

IN

G

B R

A D

L E

Y A

IR

N

A T

IO

N

A

R D

B A

S E

E A

S T

G R

A N

B Y

C

O N

N E

C T

IC

U

T

C O

M P

O S

IT

E

A S

E A

X

S F

A C

IL

IT

Y

Drawing No.:

C

D

A E

S

B

ARCHITECTURAL

B

IM

/U

S C

T D

C

A N

G A

S E

-V M

X S

F a c ili ty /D

C

T A

N G

A

S E

-V M

X S

F A

C

IL

IT

Y

A

R C

H .r v t

/1

/2

:1

:1

P

M

B. HENDON

J. McKINNEY

J. PERRY

03/31/2022

A-135

PARTIAL RCP -

ASE/VMXS FACILITY -

AREA E

1/8" = 1'-0"

A-200

A1

PARTIAL REFLECTED CEILING PLAN - ASE/VMXS FACILITY - AREA E

A-130

113 6"x6" CONTINUOUS SHEET METAL GUTTER, TYP.

117 MECHANICAL EQUIPMENT; REFER TO MECHANICAL

123 SHEET METAL FASCIA AND SOFFIT PANELS FORMED BY INSULATED PANEL

MANUFACTURER, TYP.

126 EXPOSED STEEL SUPERSTRUCTURE AND ROOF DECK - PAINTED, TYP.

276 FALL PROTECTION SUPPORT; REFER TO STRUCTURAL

314 FALL ARREST SYSTEM TRACK; REFER TO STRUCTURAL AND EQUIPMENT FOR

ADDITIONAL INFORMATION

315 UNIT HEATER; REFER TO MECHANICAL

REV DESCRIPTION DATE

1 AMENDMENT 001 JAN 2023

THESE DOCUMENTS ARE

INTERIM REVIEW AND NO

CONSTRUCTION, BIDDING

S1 S2 S3 S4 S5

SB

SA

S7S6

12' - 3 1/2" 24' - 0" 24' - 0" 23' - 9" 11' - 1"

12' - 0" 24' - 0" 12' - 0"

E Q

E Q

OLI

23' - 0"

BASE BID

121' - 0"

161161

COVERED

VEHICLE

OPS

PARKING

S102

HEATED

VEHICLE

OPS

STORAGE

S101

GENERAL NOTES

KEYNOTES

1. ALL GYPSUM BOARD AND ACOUSTICAL CEILINGS TO BE 10'-0"

ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED

2. REFER TO PLUMBING, MECHANICAL, ELECTRICAL, FIRE SUPPRESSION, FIRE

ALARM, AND TELECOMMUNICATION DRAWINGS FOR ALL VENTS, SPRINKLER

HEADS, GRILLES, REGISTERS, DIFFUSERS, DUCTS, LIGHT FIXTURES,

DETECTORS, ETC.; COORDINATE THESE ITEMS AS REQUIRED.

3. COORDINATE ALL STRUCTURAL, PLUMBING, MECHANICAL, FIRE

SUPPRESSION, AND ELECTRICAL WORK WITH CEILING HEIGHTS AND

ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR, COORDINATE FINAL

LOCATIONS WITH COR.

4. REFER TO ROOM FINISH SCHEDULE FOR CEILING MATERIALS, FINISHES, AND

HEIGHTS.

5. ALL CEILING-MOUNTED OR RECESSED ITEMS SHOWN - OR NOT - ON

REFLECTED CEILING PLANS (SUCH AS SPRINKLER HEADS, SPEAKERS,

SPEAKER STROBES, GRILLES, LIGHTS, ETC.) SHALL BE CENTERED IN THE LAY-

IN ACT PANELS. AT GYPSUM BOARD CEILINGS, INSTALL IN A CONSISTENT

PATTERN. LOCATE SPRINKLER HEADS IN CONSISTENT PATTERN AS

INDICATED. CEILING MOUNTED ELEMENTS DIMENSIONED TO CENTERLINES

UNLESS OTHERWISE NOTED.

6. NOTIFY COR OF ALL ITEMS NOT SHOWN ON REFLECTED CEILING PLAN AND

LOCATE PER COR DIRECTION.

7. REFER TO TELECOMMUNICATION DRAWINGS FOR CAMERA LOCATIONS.

8. REFER TO DETAILS FOR MECHANICAL, ELECTRICAL, AND PLUMBING ACCESS

PANELS IN A GYPSUM BOARD CEILING.

9. GRID LAYOUT AND LOCATIONS OF LIGHT FIXTURES AND DIFFUSERS ON THE

REFLECTED CEILING PLANS GOVERN OVER ELECTRICAL AND MECHANICAL

DRAWINGS.

10. REFER TO SPECIAL SYSTEMS DRAWINGS FOR SPEAKER TYPES & SIZES,

CAMERA TYPES & SIZES, ETC.

11. ALL CEILING PENETRATIONS SHALL BE TREATED AS PERIMETER CLOSURES

AND SHALL ALLOW A MINIMUM OF 3/8" CLEARANCE BY USE OF SUITABLE

ESCUTCHEONS OR CLOSURE DETAILS.

12. REFER TO A-510 FOR CEILING TRANSITION DETAILS.

ACCESS PANEL

RETURN AIR GRILLE; REFER TO MECHANICAL

SUPPLY AIR DIFFUSER; REFER TO MECHANICAL

RECESSED CAN DOWNLIGHT (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 4' HANGING LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 2' RECESSED LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE; REFER TO ELECTRICAL

STRIP LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING FIXTURES LEGEND

GYPSUM BOARD CEILING

ACOUSTICAL PANEL CEILING (APC) ASSEMBLY

COVERED OUTDOOR SPACE LIGHT FIXTURE (BLACK FILL

INDICATES EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING SPEAKER; REFER TO TELECOM

MANUAL ROLLER SHADE

DUAL BLACKOUT SHADE

LINEAR PENDANT FIXTURE; REFER TO ELECTRICAL

LINEAR LED FIXTURE; REFER TO ELECTRICAL

CEILING MOUNTED SENSORS; REFER TO ELECTRICALOS VSPC

EMERGENCY LIGHTING; REFER TO ELECTRICAL

WALL-MOUNTED LIGHT FIXTURE; REFER TO ELECTRICAL

SECURITY CAMERA; REFER TO TELECOM

EMERGENCY EXIT SIGN; REFER TO ELECTRICAL

FIRE ALARM DEVICE; REFER TO FIRE PROTECTION

N

4' 8' 16'

1/8" = 1'-0"

24'0

A

Designed:

Drawn:

Checked:

Date:

Drawing Title:

Jacobs Project No.:

Key Plan:

D3257200

B

C

D

2 3 4 5

Scales:

THESE DOCUMENTS ARE FOR

INTERIM REVIEW AND NOT FOR

CONSTRUCTION, BIDDING, OR

PERMIT PURPOSES.

Phase: B-3 FINAL DESIGN

C O

N N

E C

T

IC

U T

A

IR

N A

T

IO

N A

L G

U A

R D

R

D A

IR

L

IF

T

W

IN

G

B R

A D

L E

Y A

IR

N

A T

IO

N

A

R D

B A

S E

E A

S T

G R

A N

B Y

C

O N

N E

C T

IC

U

T

C O

M P

O S

IT

E

A S

E A

X

S F

A C

IL

IT

Y

Drawing No.:

C

D

A E

S

B

ARCHITECTURAL

B

IM

/U

S C

T D

C

A N

G A

S E

-V M

X S

F a c ili ty /D

C

T A

N G

A

S E

-V M

X S

F A

C

IL

IT

Y

A

R C

H .r v t

/1

/2

:1

:1

P

M

B. HENDON

J. McKINNEY

J. PERRY

03/31/2022

A-136

PARTIAL RCP -

VEHICLE OPS PARKING

BUILDING

1/8" = 1'-0"A1

REFLECTED CEILING PLAN - VEHICLE OPS PARKING BUILDING

117 MECHANICAL EQUIPMENT; REFER TO MECHANICAL

126 EXPOSED STEEL SUPERSTRUCTURE AND ROOF DECK - PAINTED, TYP.

136 GALVANIZED STEEL ACCESS LADDER WITH OSHA COMPLIANT RAIL & HARNESS

FALL ARREST SYSTEM; REFER TO A-541 & A-542

161 OLI - ADD ADDITIONAL BAY OF COVERED PARKING

315 UNIT HEATER; REFER TO MECHANICAL

REV DESCRIPTION DATE

1 AMENDMENT 001 JAN 2023

THESE DOCUMENTS ARE

INTERIM REVIEW AND NO

CONSTRUCTION, BIDDING

F'

1.5

4.5

L'

G'

H'

J'

K'

8' - 0"

8' - 0"

8' - 0"

8' - 0"

ASE

STORAGE

WASH

RACK

ASE

MAINTENANCE

AND

REPAIR

GENERAL NOTES

KEYNOTES

1. ALL GYPSUM BOARD AND ACOUSTICAL CEILINGS TO BE 10'-0"

ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED

2. REFER TO PLUMBING, MECHANICAL, ELECTRICAL, FIRE SUPPRESSION, FIRE

ALARM, AND TELECOMMUNICATION DRAWINGS FOR ALL VENTS, SPRINKLER

HEADS, GRILLES, REGISTERS, DIFFUSERS, DUCTS, LIGHT FIXTURES,

DETECTORS, ETC.; COORDINATE THESE ITEMS AS REQUIRED.

3. COORDINATE ALL STRUCTURAL, PLUMBING, MECHANICAL, FIRE

SUPPRESSION, AND ELECTRICAL WORK WITH CEILING HEIGHTS AND

ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR, COORDINATE FINAL

LOCATIONS WITH COR.

4. REFER TO ROOM FINISH SCHEDULE FOR CEILING MATERIALS, FINISHES, AND

HEIGHTS.

5. ALL CEILING-MOUNTED OR RECESSED ITEMS SHOWN - OR NOT - ON

REFLECTED CEILING PLANS (SUCH AS SPRINKLER HEADS, SPEAKERS,

SPEAKER STROBES, GRILLES, LIGHTS, ETC.) SHALL BE CENTERED IN THE LAY-

IN ACT PANELS. AT GYPSUM BOARD CEILINGS, INSTALL IN A CONSISTENT

PATTERN. LOCATE SPRINKLER HEADS IN CONSISTENT PATTERN AS

INDICATED. CEILING MOUNTED ELEMENTS DIMENSIONED TO CENTERLINES

UNLESS OTHERWISE NOTED.

6. NOTIFY COR OF ALL ITEMS NOT SHOWN ON REFLECTED CEILING PLAN AND

LOCATE PER COR DIRECTION.

7. REFER TO TELECOMMUNICATION DRAWINGS FOR CAMERA LOCATIONS.

8. REFER TO DETAILS FOR MECHANICAL, ELECTRICAL, AND PLUMBING ACCESS

PANELS IN A GYPSUM BOARD CEILING.

9. GRID LAYOUT AND LOCATIONS OF LIGHT FIXTURES AND DIFFUSERS ON THE

REFLECTED CEILING PLANS GOVERN OVER ELECTRICAL AND MECHANICAL

DRAWINGS.

10. REFER TO SPECIAL SYSTEMS DRAWINGS FOR SPEAKER TYPES & SIZES,

CAMERA TYPES & SIZES, ETC.

11. ALL CEILING PENETRATIONS SHALL BE TREATED AS PERIMETER CLOSURES

AND SHALL ALLOW A MINIMUM OF 3/8" CLEARANCE BY USE OF SUITABLE

ESCUTCHEONS OR CLOSURE DETAILS.

12. REFER TO A-510 FOR CEILING TRANSITION DETAILS.

ACCESS PANEL

RETURN AIR GRILLE; REFER TO MECHANICAL

SUPPLY AIR DIFFUSER; REFER TO MECHANICAL

RECESSED CAN DOWNLIGHT (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 4' HANGING LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

2' x 2' RECESSED LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE; REFER TO ELECTRICAL

STRIP LIGHT FIXTURE (BLACK FILL INDICATES

EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING FIXTURES LEGEND

GYPSUM BOARD CEILING

ACOUSTICAL PANEL CEILING (APC) ASSEMBLY

COVERED OUTDOOR SPACE LIGHT FIXTURE (BLACK FILL

INDICATES EMERGENCY FIXTURE); REFER TO ELECTRICAL

CEILING SPEAKER; REFER TO TELECOM

MANUAL ROLLER SHADE

DUAL BLACKOUT SHADE

LINEAR PENDANT FIXTURE; REFER TO ELECTRICAL

LINEAR LED FIXTURE; REFER TO ELECTRICAL

CEILING MOUNTED SENSORS; REFER TO ELECTRICALOS VSPC

EMERGENCY LIGHTING; REFER TO ELECTRICAL

WALL-MOUNTED LIGHT FIXTURE; REFER TO ELECTRICAL

SECURITY CAMERA; REFER TO TELECOM

EMERGENCY EXIT SIGN; REFER TO ELECTRICAL

FIRE ALARM DEVICE; REFER TO FIRE PROTECTION

N

A

Designed:

Drawn:

Checked:

Date:

Drawing Title:

Jacobs Project No.:

Key Plan:

D3257200

B

C

D

2 3 4 5

Scales:

THESE DOCUMENTS ARE FOR

INTERIM REVIEW AND NOT FOR

CONSTRUCTION, BIDDING, OR

PERMIT PURPOSES.

AS INDICATED

Phase: B-3 FINAL DESIGN

C O

N N

E C

T

IC

U T

A

IR

N A

T

IO

N A

L G

U A

R D

R

D A

IR

L

IF

T

W

IN

G

B R

A D

L E

Y A

IR

N

A T

IO

N

A

R D

B A

S E

E A

S T

G R

A N

B Y

C

O N

N E

C T

IC

U

T

C O

M P

O S

IT

E

A S

E A

X

S F

A C

IL

IT

Y

Drawing No.:

C

D

A E

S

B

ARCHITECTURAL

B

IM

/U

S C

T D

C

A N

G A

S E

-V M

X S

F a c ili ty /D

C

T A

N G

A

S E

-V M

X S

F A

C

IL

IT

Y

A

R C

H .r v t

/1

/2

:1

:1

P

M

B. HENDON

J. McKINNEY

J. PERRY

03/31/2022

A-137

PARTIAL RCP - ASE

WASH RACK BID

OPTION

1/8" = 1'-0" A1

PARTIAL REFLECTED CEILING PLAN - ASE/VMXS FACILITY - ASE WASH RACK BID OPTION

REV DESCRIPTION DATE

1 AMENDMENT 001 JAN 2023

THESE DOCUMENTS ARE

INTERIM REVIEW AND NO

CONSTRUCTION, BIDDING

Sheets
A-130 - OVERALL REFLECTED CEILING PLAN - ASE/VMXS FACILITY
A-131 - PARTIAL RCP - ASE/VMXS FACILITY - AREA A
A-132 - PARTIAL RCP - ASE/VMXS FACILITY - AREA B
A-133 - PARTIAL RCP - ASE/VMXS FACILITY - AREA C
A-134 - PARTIAL RCP - ASE/VMXS FACILITY - AREA D
A-135 - PARTIAL RCP - ASE/VMXS FACILITY - AREA E
A-136 - PARTIAL RCP - VEHICLE OPS PARKING BUILDING
A-137 - PARTIAL RCP - ASE WASH RACK BID OPTION
A-601 - FINISH SCHEDULE & TOILET ACCESSORIES SCHEDULE
A-610 - DOOR TYPES & DOOR SCHEDULE

File details come from the government source that posted it. Updated .