Mandatory Signs 1.pdf
PDF 4 MB Posted
- Solicitation number
- W50SC2-23-R-0001
- Issued by
-
Department of the Army National Guard
About this file
This solicitation is seeking proposals to construct an Aircraft Support Equipment (ASE) and Vehicle Maintenance (VM) Facility at Bradley Air National Guard Base in East Granby, Connecticut. The project magnitude is estimated between $10,000,000 and $25,000,000. Proposals are due in accordance with the contract, drawings and technical specifications, which are available in Section 00100 of the solicitation. Funding has not yet been appropriated for this acquisition but is anticipated to become available prior to award, as this project has been identified on the National Guard's priority list. No contract will be awarded until funds are available. The North American Industry Classification for this project is 236220, with a small business size standard of $39.5 million average annual revenue for the past three years. A single award contract is contemplated. Failure to submit an offer on all items will result in rejection of the proposal.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UL 1994 • UL 924 • ASTM E2072/2073 • IBC/IFC • NFPA
2021 Edition
Photoluminescent Exit, Egress, Safety, & First Responder Catalog
Photoluminescent Exit Signs
EXIT SIGNS - NO ELECTRICITY REQUIRED!
Quickly and easily identify exits if the lights go out through the use of advanced photoluminescent lettering. Variety of signs and mounting options available. No batteries or electricity required, easy to install, no wires, no need to hire an electrician, LEED Certified and UL 924 Listed. IBC/IFC compliant. Use these signs to replace existing electric signs.
Eligible for 3 different LEED Credits.
See page 10 for more information.
LUCITE
Clear with Universal Wall/Ceiling Mounting Kit, One-Sided
NSN 4240-00-NIB-0269
Mirrored with Universal Wall/ Ceiling Mounting Kit, One-Sided
NSN 4240-00-NIB-0270
Mirrored, Double-Sided Conversion, No Frame, No Mount (can be used with
NSN 4240-00-NIB-0270)
NSN 4240-00-NIB-0271
A) 3” ceiling mount disc (to be used with 4’ Drop Down P ost Extension)
Item #1-309-1605F
B) 4’ Drop Down Post Extension (to be used with Item
#3-309-0001 or #1-309-1606M) Item #1-309-160548
C) Universal Channel Mount Kit - Ceiling or Wall Mount, Compatible with one or two-sided metal or lucite signs Item #1-309-1606CM
D) Brushed Aluminum Frame with Wall and Ceiling Mounting Kit
Item #3-309-0001
A
MOUNTING
OPTIONS
B
C
D
100’ VISIBILITY METAL EXIT SIGNS
Silver, Green, Red, or White Composite Metal Exit Sign, No Frame, No Mount, One-Sided Custom Colors Available - NSN 4240-00-NIB-5998
(Silver) NSN 4240-00-NIB-5997 (Green) NSN 4240-00-NIB-5995
(Red) NSN 4240-00-NIB-5994 (White) NSN 4240-00-NIB-5996
PHOTOLUMINESCENT EXIT SIGN
EXIT-PL-100
E363520 CABVI1
“NOTICE: MAXIMUM VIEWING DISTANCE 100 FEET (30.48 METERS) SUITABLE FOR OUTDOOR WET LOCATIONS”
CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.
“NOTICE: MAXIMUM VIEWING DISTANCE 100 FEET (30.48 METERS) SUITABLE FOR OUTDOOR WET LOCATIONS”
CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.
“NOTICE: MAXIMUM VIEWING DISTANCE 100 FEET (30.48 METERS) SUITABLE FOR OUTDOOR WET LOCATIONS”
CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.
PHOTOLUMINESCENT EXIT SIGN
EXIT-GR-PL-100
E363520 CABVI1
“NOTICE: MAXIMUM VIEWING DISTANCE 100 FEET (30.48 METERS) SUITABLE FOR OUTDOOR WET LOCATIONS”
CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.
PHOTOLUMINESCENT EXIT SIGN
EXIT-RD-PL-100
E363520 CABVI1
“NOTICE: MAXIMUM VIEWING DISTANCE 100 FEET (30.48 METERS) SUITABLE FOR OUTDOOR WET LOCATIONS”
CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.
PHOTOLUMINESCENT EXIT SIGN
EXIT-WH-PL-100
E363520 CABVI1
Silver, Green, Red, or White Composite Metal Exit Sign, No Frame, No Mount, One-Sided (Silver) NSN 4240-00-NIB-0243
(Green) 5-309-1602PMG2S (Red) 6-309-1602PMR
(White) 6-309-1602PMW
CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.
PHOTOLUMINESCENT EXIT SIGN
EG EXIT M GR
E483541
“NOTICE: MAXIMUM VIEWING DISTANCE 50 FEET (15.24 METERS)”
CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.
PHOTOLUMINESCENT EXIT SIGN
EG EXIT M RD
E483541
“NOTICE: MAXIMUM VIEWING DISTANCE 50 FEET (15.24 METERS)”
CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.
PHOTOLUMINESCENT EXIT SIGN
EG EXIT M WH
E483541
“NOTICE: MAXIMUM VIEWING DISTANCE 50 FEET (15.24 METERS)”
50’ VISIBILITY METAL EXIT SIGNS
NOT AN EXIT
EXIT Left or Right, 8 x 8 (Left) NSN 4240-00-NIB-0295
(Right) NSN 4240-00-NIB-0296
Stairwell Floor Identifier, Floors 1 - 10, 8 x 8, See page 8 for Product Numbers
Stairs, 8 x 8
NSN 4240-00-NIB-0297
Not an Exit, 8 x 8
NSN 4240-00-NIB-0294
Directional Arrow, 8 x 8 (Side) NSN 4240-00-NIB-0292
(Corner) NSN 4240-00-NIB-0293
FLOOR
1E X I T
Photoluminescent Safety Signs
PVC SIGNS
Our photoluminescent safety signs utilize advanced photoluminescent technology, which brightly illuminates surrounding areas and stays visible in the dark for hours. Signs may be recharged indefinitely. Photoluminescent safety signs (such as running man, floor number signs, etc.) are available in a variety of sizes. Custom signs, colors, and sizes are also available.
Photoluminescent signs are the MOST energy efficient signs available. No batteries or electricity required, easy to install, no wires, no need to hire an electrician.
NON-PHOTOLUMINESCENT PVC SIGNS
ADHESIVE LABELS
Door Remain Unlocked, 8 x 8
NSN 4240-00-NIB-0299
THIS DOOR
MUST REMAIN
UNLOCKED
DURING
BUSINESS
HOURS
No Smoking, 8 x 8
NSN 4240-00-NIB-0301
Fire Door, 8 x 8
NSN 4240-00-NIB-0300
THIS IS A
FIRE DOOR
KEEP CLOSED!
THIS FIRE DOOR HAS BEEN INSTALLED FOR YOUR
PROTECTION IN CASE OF FIRE, IT MAY SAVE YOUR LIFE.
IT SHOULD BE KEPT CLOSED AT ALL TIMES WHEN NOT IN USE.
DO NOT BLOCK
OR FASTEN OPEN!
Custom PVC Sign on White Vinyl, 8 x 8
NSN 4240-00-NIB-0302
YOUR
DESIGN
HERE
EMERGENCY EXIT
Emergency Exit, Green, 12 x 3
NSN 4240-00-NIB-0273
S T A N D P I E P
Standpipe, 3 x 8
NSN 4240-00-NIB-0272
Emergency Exit, Red, 12 x 3 5-309-2010
EMERGENCY EXIT
Running Man, 12 x 6
NSN 4240-00-NIB-0274
Fire Extinguisher, 6 x 12
NSN 4240-00-NIB-0275
EXIT, 12 x 9
NSN 4240-00-NIB-0303
Time Delayed Door, 9 x 12
NSN 4240-00-NIB-0304
In Case of Fire, 9 x 12
NSN 4240-00-NIB-0305
PRESS
BAR
Alarm Will Sound
TIME-DELAYED EXIT DOOR
WAIT
PUSH
DOOR
OPEN
In case of fire
Do not use elevator
Use the EXIT stairs
CUSTOM PVC SIGNS
Custom PVC Sign , 8 x 8
NSN 4240-00-NIB-0298
YOUR
DESIGN
HERE
Custom PVC Sign on White Vinyl, 8 x 8
NSN 4240-00-NIB-0302
YOUR
DESIGN
HERE
Custom PVC Sign, 9 x 12
NSN 4240-00-NIB-0306
YOUR
DESIGN
HERE
NEW Photoluminescent Products
CUSTOM SIGNS
For more information, contact Bryan Heeb at 859-445-1677 or bryan.heeb@cincyblind.org
Semi-Rigid Tape Strip for Stairs, Yellow/Green, 47” x 1”
4240-00-NIB-3220
2018 INTERNATIONAL BUILDING CODE
Section 1025: Luminous Egress Path Markings
1025.1 General.
Approved luminous egress path markings delineating the exit path shall be provided in high-rise buildings of Group A, B, E, I-1, M or R-1 occupancies in accordance with this section.
Exception: Luminous egress path markings shall not be required on the level of exit discharge in lobbies that serve as part of the exit path in accordance with Section 1028.1, Exception 1.
1025.2 Markings within exit components.
Egress path markings shall be provided in interior exit stairways, interior exit ramps and exit passageways, in accordance with Sections 1025.2.1 through 1025.2.6.
1025.2.1 Steps
A solid and continuous stripe shall be applied to the horizontal leading edge of each step and shall extend for the full length of the step. Outlining stripes shall have a minimum horizontal width of 1 inch (25 mm) and a maximum width of 2 inches (51 mm). The leading edge of the strip shall be placed not more than 1/₂ inch (12.7 mm) from the leading edge of the step and the stripe shall not overlap the leading edge of the step by not more than 1/₂ inch (12.7 mm) down the vertical face of the step.
Exception: The minimum width of 1 inch (25 mm) shall not apply to outlining stripes listed in accordance with UL 1994.
1025.2.2 Landings.
The leading edge of landings shall be marked with a stripe consistent with the dimensional requirements for steps.
Door Knob Locator Ring, 5.5” or 4.5”, 5 Per Pack
(5.5”) 4240-00-NIB-3232
(4.5”) 4240-00-NIB-3233
PHOTOLUMINESCENT EGRESS PRODUCTS
Photoluminescent Tapes
TAPES
Illuminate your railings, door openings, floors and other items including: apparatus, ladder beams and more with our photoluminescent adhesive tape. This tape will glow for several hours when fully charged. Tape has been UL tested to exceed ASTM E2072/3 per UL 1994. Meets IBC/IFC and NFPA Standards. Photoluminescent multipurpose adhesive tape with directional arrows. Illuminates exits and escape routes to safely direct people if the lights go out. Can be charged by any light source (sun, artificial light, low light). Will illuminate surroundings for several hours when fully charged.
Can withstand high temperatures. May be re-charged repeatedly. Available in 25’ and 50’ lengths.
HIGHLIGHTS:
Made with advanced photoluminescent technology™ using 3M® industrial grade adhesive.
• Durable, designed to withstand high temperatures
• Can be charged by any light source (sun, artificial light, low light) & will recharge indefinitely
• Laboratory tested to emit light up to 30 hours* when fully charged
• UL tested to exceed ASTM E2072 standard for photoluminescent (phosphorescent) safety markings
Available in 25’ & 50’ Lengths
(25’) NSN 4240-00-NIB-0244
(50’) NSN 4240-00-NIB-0245
With Directional Arrows, Available in 25’ & 50’ Lengths
(25’) NSN 4240-00-NIB-0246
(50’) NSN 4240-00-NIB-0247
Grip Wrap Available in 5’ & 10’ Lengths
(5’) NSN 4240-00-NIB-0237
(10’) NSN 4240-00-NIB-0238
Helmet Band:
Track firefighters and increase safety in smoky or dark environments.
NSN 4240-00-NIB-0248
Customizable Adhesive Label 6 3/₈ x 3 1/₂ :
Quickly and easily identify individual firefighters in smoky conditions.
NSN 4240-00-NIB-0276
Photoluminescent Products for First Responders
FIRST RESPONDERS
Help keep your first responders safe with our photoluminescent safety products. These products use our advanced photoluminescent technology to keep your first responders visible in dark or smoky conditions.
Cost Savings Summary
ASSUMPTIONS
EXIT SIGN ENERGY USE BY THE NUMBERS
Annual Carbon
Dioxide (CO2) Pollution
0 Pounds
72 Pounds
230 Pounds
574 Pounds
Exit Sign Lighting Technology
Our Signs
LED
Fluorescent/CFL
Incandescent
Annual Energy Use
0 kWh
44 kWh
140 kWh
350 kWh
Annual Energy Costs
$0
$4
$11
$28
Lamp Service Life
Not Applicable
10+ Years
10.8 Months
2.8 Months
Table from www.energystar.gov and modified to include our products.
Annual Energy Use and Costs Our Signs vs. Traditional/LED Exit Signs
$50
$40
$30
$20
$10
$ 0
350 kWh
140 kWh
44 kWh CABVI LED Fluorescent/CFL Incandescent
ENERGY USE
EN
ER
G Y
CO
ST
S
Annual Carbon Dioxide (CO2) Pollution Our Signs vs. Traditional/LED Exit Signs
CABVI LED Fluorescent/CFL Incandescent
ENERGY USE
PO
U
N D
S
It is widely believed that it costs between $200 and $500 for the sign cost and installation of a traditional or LED exit sign. For purposes of our analysis we have chosen costs in the low range at $280.
We have estimated the annual operating cost of LED, fluorescent and incandescent signs to be $57, $71 and $88 respectively. Our exit sign has no annual operating costs. Our analysis includes replacing each LED exit sign when they go bad at a cost of $40 ($30 for sign and $10 for labor).
In our analysis of existing locations, we have increased the cost of installation by $10 to remove the existing exit sign and cap the electricity.
Monthly inspections: According to NFPA101, electric exit signs must undergo a 30-second test every month.
Yearly inspections: NFPA101 also requires that electric exit signs simulate being on battery backup for 90 minutes every year.
NO ANNUAL
TESTING
REQUIRED!
ANNUAL COST SAVINGS OF $50 - $85 DOLLARS PER YEAR PER SIGN!
IncandescentFluorescentLEDCABVI
Install Sign Cost Labor
Annual Cost Batteries Bulbs Periodic Testing Electricity Replacement Sign ($30 ea x 20%) Replacement Labor ($10 ea x 20%)
$80 $10 $90
$0
$30 $250 $280
$15
$30 $4 $6
$2
$57
$25 $250 $275
$15 $15 $30 $11
$71
$20 $250 $270
$15 $15 $30 $28
$88
15 YEAR SAVINGS
with CABVI Exit Signs
$15M
$10M
$5M
CABVI
vs. LED
CABVI
vs. Fluorescent
CABVI
vs. Incandescent
New Construction Existing Construction
Cost Savings Summary
$7-$14+
MILLION
DOLLAR
SAVINGS
PER 10,000
SIGNS
CABVI SAFETY EXIT SIGN SAVINGS PER 10,000 SIGNS
CABVI vs. IncandescentCABVI vs. FluorescentCABVI vs. LED
New Construction Immediate Install Savings 15 Year Savings
Existing Locations Initial Investment Return on Investment Total Savings (15 years) Payback in Years Internal Rate of Return
$1,500,000 $10,050,000
$1,500,000 570%
$7,050,000 2.6
38%
$1,450,000 $12,100,000
$1,500,000 710%
$9,150,000 2.1
47%
$1,400,000 $14,600,000
$1,500,000 880%
$11,700,000 1.7
59%
Photoluminescent Product Numbers
Adhesive Tape, 1 1/4” x 25’ Adhesive Tape, 1 1/4” x 50’ Adhesive Tape with Directional Arrows, 1 1/4” x 25’ Adhesive Tape with Directional Arrows, 1 1/4” x 50’ 5.5” Door Knob Locator Ring, 5 Per Pack 4.5” Door Knob Locator Ring, 5 Per Pack Semi-Rigid Tape Strip for Stairs, 1” x 42”
4240-00-NIB-0244
4240-00-NIB-0245
4240-00-NIB-0246
4240-00-NIB-0247
3-309-DK02-5
3-309-DK01-5
3-309-SN01
Photoluminescent Tapes & Egress Products
50’ Silver Composite Metal Exit Sign with Frame, Post Mount and Kit, One-Sided 50’ Silver Composite Metal Exit Sign with Frame, Post Mount and Kit, Two-Sided 50’ Silver Composite Metal Exit Sign with Frame, Wall Mount, One-Sided 50’ Silver Composite Metal Exit Sign, No Frame, No Mount, One-Sided 50’ Clear Exit Sign with Universal Wall/Ceiling Mounting Kit, One-Sided 50’ Mirrored Exit Sign with Universal Wall/Ceiling Mounting Kit, One-Sided 50’ Mirrored Exit Sign, Double-Sided Conversion, No Frame, No Mount (to be used with item # 4240-00-NIB-0270) 50’ Green Composite Metal Exit Sign, No Frame, No Mount, One-Sided 50’ Red Composite Metal Exit Sign, No Frame, No Mount, One-Sided 50’ White Composite Metal Exit Sign, No Frame, No Mount, One-Sided 100’ Silver Composite Metal Exit Sign, No Frame, No Mount, One-Sided 100’ Red Composite Metal Exit Sign, No Frame, No Mount, One-Sided 100’ Green Composite Metal Exit Sign, No Frame, No Mount, One-Sided 100’ White Composite Metal Exit Sign, No Frame, No Mount, One-Sided 100’ Custom Color Composite Metal Exit Sign, No Frame, No Mount, One-Sided
4240-00-NIB-0240
4240-00-NIB-0241
4240-00-NIB-0242
4240-00-NIB-0243
4240-00-NIB-0269
4240-00-NIB-0270
4240-00-NIB-0271
5-309-1602PMG2S
6-309-1602PMR
6-309-1602PMW
6-309-1602PM-100
6-309-1601PMR-100
6-309-1602PMG-100
6-309-1602PMW-100
6-309-1602PMC-100
Photoluminescent Exit Signs
Photoluminescent Adhesive Label, “Standpipe”, 3 x 8 Photoluminescent Adhesive Label, “Emergency Exit”, Green, 12 x 3 Photoluminescent Adhesive Label, “Emergency Exit”, Red, 12 x 3 Photoluminescent PVC Sign, Running Man with Directional Arrow, 12 x 6, Bottom Right Photoluminescent PVC Sign, Fire Extinguisher, 6 x 12 Photoluminescent PVC Sign, “Floor 1” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 2” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 3” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 4” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 5” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 6” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 7” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 8” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 9” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 10” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, Side Directional Arrow, 8 x 8 Photoluminescent PVC Sign, Corner Directional Arrow, 8 x 8 Photoluminescent PVC Sign, “Not an Exit”, 8 x 8 Photoluminescent PVC Sign, EXIT Left, 8 x 8 Photoluminescent PVC Sign, EXIT Right, 8 x 8 Photoluminescent PVC Sign, Stairs, 8 x 8 Photoluminescent PVC Sign, Custom Printed, 8 x 8 PVC Sign, “Door Remain Unlocked”, 8 x 8 PVC Sign, “Fire Door Keep Closed”, 8 x 8 PVC Sign, “No Smoking”, 8 x 8 PVC Sign, Custom Printed, 8 x 8 Photoluminescent PVC Sign, EXIT, 12 x 9 Photoluminescent PVC Sign, “Time Delayed Door”, 9 x 12 Photoluminescent PVC Sign, “In Case of Fire”, 9 x 12 Photoluminescent PVC Sign, Custom Printed, 9 x 12
4240-00-NIB-0272
4240-00-NIB-0273
5-309-2010
4240-00-NIB-0274
4240-00-NIB-0275
4240-00-NIB-0282
4240-00-NIB-0283
4240-00-NIB-0284
4240-00-NIB-0285
4240-00-NIB-0286
4240-00-NIB-0287
4240-00-NIB-0288
4240-00-NIB-0289
4240-00-NIB-0290
4240-00-NIB-0291
4240-00-NIB-0292
4240-00-NIB-0293
4240-00-NIB-0294
4240-00-NIB-0295
4240-00-NIB-0296
4240-00-NIB-0297
4240-00-NIB-0298
4240-00-NIB-0299
4240-00-NIB-0300
4240-00-NIB-0301
4240-00-NIB-0302
4240-00-NIB-0303
4240-00-NIB-0304
4240-00-NIB-0305
4240-00-NIB-0306
Safety Signs
ITEM NAME PAGE NUMBERITEM NUMBER
First Responders
Grip Wrap 5’ Grip Wrap 10’ Helmet Band Label, Custom, SBCA ID, Adhesive Back, Photoluminescent SCBA ID Tag, Metal
4240-00-NIB-0237
4240-00-NIB-0238
4240-00-NIB-0248
4240-00-NIB-0276
4240-00-NIB-0239
Reference Letter
The Honorable Stephen T. Ayers Architect of the Capitol SB-15, U.S. Capitol Washington, DC 20515
Dear Mr. Ayers, Recent incidents at federal buildings, including the U.S. Capitol Complex, have been a sobering reminder of the unique challenges we face as we work to ensure the safety and security of the millions of Americans who visit and work in federal government buildings every day.
Effective signage to guide people to safety is just one component of sound emergency preparedness.
I write to bring to your attention a new, state-of-the-art technology that I believe may provide a cost-effective solution to some of these unique safety challenges at federal buildings.
Photoluminescent technology may be used in the form of signage, such as exit signs for office buildings with complex architectural layouts. These photoluminescent signs offer several advantages over traditional signs because they do not require electricity to operate.
In the event of an emergency, people rely on exit signs to guide them to safety. However, the vast majority of traditional exit signs require electricity to operate. If a natural disaster, terrorist attack or power outage were to occur, a federal building’s electricity supply could be compromised, rendering traditional electric signs, useless, jeopardizing the safety and security of all occupants.
Moreover, the electricity required to operate traditional electric safety signs increases building operational costs through higher electricity consumption.
Reports from Energystar.gov indicate that this technology is more energy-efficient and less costly than the old electric and LED signs.
As Energystar.gov indicates, Photoluminescent exit signs are a potential cost-saving alternative to the traditional signs in the following ways:
• Photoluminescent signs require no back-up batteries
• Photoluminescent signs require no light bulbs to replace
• Photoluminescent signs require no electricity
• Photoluminescent signs require no periodic testing
Because of these differences, photoluminescent technology can offer substantial cost savings. As we look for new and improved ways to ensure the safety and security of the people who visit and work in federal buildings in these dangerous times, I respectfully request that you give the use of photoluminescent exit and safety signs every full and fair consideration in accordance with all applicable laws and regulations.
This innovative technology has the potential to save lives while saving the taxpayers money. As such, I believe it is worthy of consideration as a viable alternative to the electric signs.
Thank you in advance for your consideration and should you require any additional information, please do not hesitate to reach out to Chris Hess in my office at Chris.Hess@mail.house.gov or 202-225-2216. Additionally, please feel free to make this correspondence part of any public record.
Sincerely, Steve Chabot Member of Congress
Brad Wenstrup Member of Congress
ID Credit #1.1
Innovation in Design:
Significant Environmental Benefits
MR Credit #4
Materials and Resources:
Recycled Content
EA Credit #1
Energy and Atmosphere:
Optimizing Energy Performance
LEED Certified
To qualify for this LEED V2.2 Credit [worth up to 10 points] a building project must demonstrate improvement in the proposed building energy performance compared to a baseline criteria specified in ASHRAE/IESNA Standard 90.1, or comply with prescriptive measures of ASHRAE ‘Advanced Energy Design Guide for Small Office Buildings’, or comply with the ‘Basis Criteria and Prescriptive Measures’ of the Advanced Buildings Benchmark.
More points are awarded to building projects using less energy than “baseline” guidelines prescribed by ASHRAE or the Advanced Buildings Benchmark.
With respect to exit signs, these guidelines are formulated on the basis of installing modern LED exit signs which use about 5 watts of power. Although the impact of a few exit signs using 5 watts is not significant, larger facilities can employ thousands of exit signs in high and low applications. Recognizing that electrically powered exit signs must be energized 24 hours/day x 365 days/year, a typical large building project with 500 LED exit signs, each using 5 watts of power, burns nearly 22,000 kwh of electricity annually, costing about $3,000 at $.14/kwh.
Since our Photoluminescent Exit Signs are charged from nearby area lighting and require no direct power, there is no related electricity cost. Consequently, our Photoluminescent Exit Signs will positively contribute to the calculations that determine the energy efficiency of a building project. Depending upon the number of exit signs in your building, this additional energy savings can be significant in obtaining points toward EA Credit #1.
There are two avenues available to obtain Innovation in Design points. Using our Photoluminescent Exit Signs works best with the avenue whereby the project team demonstrates a comprehensive approach toward employing a product or technology that has significant environmental benefits not addressed or credited in other LEED categories. The comprehensive approach targets optimizing the benefits and trade-offs of an innovation proposal throughout its life cycle phases: design, procurement, construction, operational and decommissioning.
The advantages of our Photoluminescent Exit Signs span all the life cycle phases with the following environmental benefits:
• Fewer Building Materials Required
• Energy Efficient
• High Percentage of Recycled and Recyclable Materials
• No Hazardous Materials or Wastes
• Longer Lifespan
• Less Maintenance
MR Credit #4 requires that 10% of the dollar value of permanently installed project materials consist of recycled content. The recycled content value of a material is determined by its adjusted recycled weight [=100% post consumer component weight + 50% pre-consumer component weight] multiplied by the total dollar value of the assembly.
Since several of our Photoluminescent Exit Signs are made primarily of metal with a high recycled content, these exit signs will contribute greatly toward this credit.
As an example, for a typical $89.95 aluminum wall mount Photoluminescent Exit Sign that weighs approx. 12.8 oz:
• Post-consumer recycled content component weight = 5.9 oz
• Pre-consumer recycled content component weight = 2.5 oz
• Non-recycled component weight = 4.4 ounces
Recycled content value = [100% x [5.9/12.8 + .5 x 2.5/12.8]] x $89.95 of one exit sign = $49
Compliance Certification
See General Information for Exit Signs, Self-luminous and Photoluminescent
CINCINNATI ASSOCIATION FOR THE BLIND AND VISUALLY IMPAIRED
2045 Gilbert Ave Cincinnati, OH 45202 USA
Photoluminescent exit sign, Models EG-Exit-CLR-BE, EG-Exit-CLR-BL, EG-Exit-CLR-GR, EG-Exit-CLR-RD, EG-Exit-PL-BE, EG-Exit-PL-BL, EG-Exit-PL-GR, EG-Exit-PL-RD, EG-Exit-BE-PL, EG-Exit-BL-PL, EG-Exit-GN-PL, EG-Exit-GR-PL, EG-Exit-RD-PL, EG-Exit-M-BE, EG-Exit-M-BL, EG-Exit-M-GR and EG-Exit-M-RD, rated viewing distance 50 ft, minimum 5ft-c unfiltered fluorescent, metal halide, mercury vapor, or LED external illumination, Suitable for Floor Proximity Installation.
The appearance of a company’s name or product in this database does not in itself assure that products so identified have been manufactured under UL’s Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL’s Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions:
1. The Guide Information, Assembles, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings).
2. The statement “Reprinted from the Online Certifications Directory with permission from UL” must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: “© 2016 UL LLC”.
Exit Signs, Self-luminous and Photoluminescent
FWBX.E483541
Exit Signs, Self-luminous and Photoluminescent
E483541
All products in this catalog are assembled and/or packaged at the Cincinnati Association for the Blind & Visually Impaired.
Cincinnati Association for the Blind & Visually Impaired is a 501(c)(3) not-for-profit organization.
Our mission is to empower people of Greater Cincinnati who are blind or visually impaired with opportunities to seek independence, which includes providing employment opportunities to people who are visually impaired or legally blind since 1911. With the national average of unemployment for people who are legally blind at nearly 70%, we are passionate about providing solutions that put people and ideas to work.
BRINGING SAFETY TO LIGHT.
File details come from the government source that posted it. Updated .