About this file

This solicitation is seeking proposals to construct an Aircraft Support Equipment (ASE) and Vehicle Maintenance (VM) Facility at Bradley Air National Guard Base in East Granby, Connecticut. The project magnitude is estimated between $10,000,000 and $25,000,000. Proposals are due in accordance with the contract, drawings and technical specifications, which are available in Section 00100 of the solicitation. Funding has not yet been appropriated for this acquisition but is anticipated to become available prior to award, as this project has been identified on the National Guard's priority list. No contract will be awarded until funds are available. The North American Industry Classification for this project is 236220, with a small business size standard of $39.5 million average annual revenue for the past three years. A single award contract is contemplated. Failure to submit an offer on all items will result in rejection of the proposal.

View the file

Other files

File Type Posted
CEKT179200 Geotechnical Report - CTANG - Final.pdf PDF
W50SC2-23-R-0001 Amendment 0002 SF 30.pdf PDF
C-304 - Civil Details_Amendment 002.pdf PDF
122413 - Roller Window Shades_Amendment 002.pdf PDF
104416 FL - Fire Extinguishers_Amendment 002.pdf PDF
FS001_Amendment 002.pdf PDF
W50SC223R0001 RFI Log 20230118.pdf PDF
CTANG ASE-VMXS _ RPF Building Survey Report October 2019_Amendment 002.pdf PDF
024119 FL - Selective Demolition_Amendment 002.pdf PDF
W50SC2-23-R-0001 Amendment 0001 SF 30.pdf PDF
Small Business Participation Plan Form.pdf PDF
329300 - Plants_Amendment 001.pdf PDF
A-130 - A-137 - RCPs_ Amendment 001.pdf PDF
A-610 - Door Schedule_Amendment 001.pdf PDF
101400 - Signage_Amendment 001.pdf PDF
C-304 - Civil Details_Amendment 001.pdf PDF
329113 - Soil Preparation_Amendment 001.pdf PDF
311000 - Site Clearing_Amendment 001.pdf PDF
334200 - Stormwater Conveyance_Amendment 001.pdf PDF
093013 Ceramic Tiling_Amendment 001.pdf PDF
C-306 - Civil Details_Amendment 001.pdf PDF
W50SC223R0001 RFI Log 20230112.pdf PDF
A-601 - Finish Schedule - Amendment 001.pdf PDF
Pre-Proposal Conference Attendance Sheet 20230105.pdf PDF
CE Pre-Proposal Slides.pdf PDF
Contracting Pre-Proposal Slides.pdf PDF
W50SC223R0001 RFI Log 20221228.pdf PDF
W50SC223R0001 RFI Log 20221222.pdf PDF
W50SC223R0001 RFI Log 20221201.pdf PDF
Brand Name JA CEKT179200 signed.pdf PDF
W50SC2-23-R-0001.pdf PDF
Mandatory Signs 2.pdf PDF
Manadatory Door Hardware.pdf PDF
EXHIBIT B - Subcontractor Information and Consent Form.docx DOCX document
EXHIBIT D - Letter of Commitment ok Key Personnel.docx DOCX document
EXHIBIT A - Performance Relevancy Questionnaire.docx DOCX document
Mandatory Sign Part Numbers.pdf PDF
EXHIBIT C - Reference_Questionnaire_Package.docx DOCX document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UL 1994 • UL 924 • ASTM E2072/2073 • IBC/IFC • NFPA

2021 Edition

Photoluminescent Exit, Egress, Safety, & First Responder Catalog

Photoluminescent Exit Signs

EXIT SIGNS - NO ELECTRICITY REQUIRED!

Quickly and easily identify exits if the lights go out through the use of advanced photoluminescent lettering. Variety of signs and mounting options available. No batteries or electricity required, easy to install, no wires, no need to hire an electrician, LEED Certified and UL 924 Listed. IBC/IFC compliant. Use these signs to replace existing electric signs.

Eligible for 3 different LEED Credits.

See page 10 for more information.

LUCITE

Clear with Universal Wall/Ceiling Mounting Kit, One-Sided

NSN 4240-00-NIB-0269

Mirrored with Universal Wall/ Ceiling Mounting Kit, One-Sided

NSN 4240-00-NIB-0270

Mirrored, Double-Sided Conversion, No Frame, No Mount (can be used with

NSN 4240-00-NIB-0270)

NSN 4240-00-NIB-0271

A) 3” ceiling mount disc (to be used with 4’ Drop Down P ost Extension)

Item #1-309-1605F

B) 4’ Drop Down Post Extension (to be used with Item

#3-309-0001 or #1-309-1606M) Item #1-309-160548

C) Universal Channel Mount Kit - Ceiling or Wall Mount, Compatible with one or two-sided metal or lucite signs Item #1-309-1606CM

D) Brushed Aluminum Frame with Wall and Ceiling Mounting Kit

Item #3-309-0001

A

MOUNTING

OPTIONS

B

C

D

100’ VISIBILITY METAL EXIT SIGNS

Silver, Green, Red, or White Composite Metal Exit Sign, No Frame, No Mount, One-Sided Custom Colors Available - NSN 4240-00-NIB-5998

(Silver) NSN 4240-00-NIB-5997 (Green) NSN 4240-00-NIB-5995

(Red) NSN 4240-00-NIB-5994 (White) NSN 4240-00-NIB-5996

PHOTOLUMINESCENT EXIT SIGN

EXIT-PL-100

E363520 CABVI1

“NOTICE: MAXIMUM VIEWING DISTANCE 100 FEET (30.48 METERS) SUITABLE FOR OUTDOOR WET LOCATIONS”

CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.

“NOTICE: MAXIMUM VIEWING DISTANCE 100 FEET (30.48 METERS) SUITABLE FOR OUTDOOR WET LOCATIONS”

CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.

“NOTICE: MAXIMUM VIEWING DISTANCE 100 FEET (30.48 METERS) SUITABLE FOR OUTDOOR WET LOCATIONS”

CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.

PHOTOLUMINESCENT EXIT SIGN

EXIT-GR-PL-100

E363520 CABVI1

“NOTICE: MAXIMUM VIEWING DISTANCE 100 FEET (30.48 METERS) SUITABLE FOR OUTDOOR WET LOCATIONS”

CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.

PHOTOLUMINESCENT EXIT SIGN

EXIT-RD-PL-100

E363520 CABVI1

“NOTICE: MAXIMUM VIEWING DISTANCE 100 FEET (30.48 METERS) SUITABLE FOR OUTDOOR WET LOCATIONS”

CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.

PHOTOLUMINESCENT EXIT SIGN

EXIT-WH-PL-100

E363520 CABVI1

Silver, Green, Red, or White Composite Metal Exit Sign, No Frame, No Mount, One-Sided (Silver) NSN 4240-00-NIB-0243

(Green) 5-309-1602PMG2S (Red) 6-309-1602PMR

(White) 6-309-1602PMW

CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.

PHOTOLUMINESCENT EXIT SIGN

EG EXIT M GR

E483541

“NOTICE: MAXIMUM VIEWING DISTANCE 50 FEET (15.24 METERS)”

CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.

PHOTOLUMINESCENT EXIT SIGN

EG EXIT M RD

E483541

“NOTICE: MAXIMUM VIEWING DISTANCE 50 FEET (15.24 METERS)”

CAUTION: Minimum 5 fc Fluorescent, Mercury Vapor, Metal Halide, or LED light on sign face at all times of building occupancy. Low Location Approved.

PHOTOLUMINESCENT EXIT SIGN

EG EXIT M WH

E483541

“NOTICE: MAXIMUM VIEWING DISTANCE 50 FEET (15.24 METERS)”

50’ VISIBILITY METAL EXIT SIGNS

NOT AN EXIT

EXIT Left or Right, 8 x 8 (Left) NSN 4240-00-NIB-0295

(Right) NSN 4240-00-NIB-0296

Stairwell Floor Identifier, Floors 1 - 10, 8 x 8, See page 8 for Product Numbers

Stairs, 8 x 8

NSN 4240-00-NIB-0297

Not an Exit, 8 x 8

NSN 4240-00-NIB-0294

Directional Arrow, 8 x 8 (Side) NSN 4240-00-NIB-0292

(Corner) NSN 4240-00-NIB-0293

FLOOR

1E X I T

Photoluminescent Safety Signs

PVC SIGNS

Our photoluminescent safety signs utilize advanced photoluminescent technology, which brightly illuminates surrounding areas and stays visible in the dark for hours. Signs may be recharged indefinitely. Photoluminescent safety signs (such as running man, floor number signs, etc.) are available in a variety of sizes. Custom signs, colors, and sizes are also available.

Photoluminescent signs are the MOST energy efficient signs available. No batteries or electricity required, easy to install, no wires, no need to hire an electrician.

NON-PHOTOLUMINESCENT PVC SIGNS

ADHESIVE LABELS

Door Remain Unlocked, 8 x 8

NSN 4240-00-NIB-0299

THIS DOOR

MUST REMAIN

UNLOCKED

DURING

BUSINESS

HOURS

No Smoking, 8 x 8

NSN 4240-00-NIB-0301

Fire Door, 8 x 8

NSN 4240-00-NIB-0300

THIS IS A

FIRE DOOR

KEEP CLOSED!

THIS FIRE DOOR HAS BEEN INSTALLED FOR YOUR

PROTECTION IN CASE OF FIRE, IT MAY SAVE YOUR LIFE.

IT SHOULD BE KEPT CLOSED AT ALL TIMES WHEN NOT IN USE.

DO NOT BLOCK

OR FASTEN OPEN!

Custom PVC Sign on White Vinyl, 8 x 8

NSN 4240-00-NIB-0302

YOUR

DESIGN

HERE

EMERGENCY EXIT

Emergency Exit, Green, 12 x 3

NSN 4240-00-NIB-0273

S T A N D P I E P

Standpipe, 3 x 8

NSN 4240-00-NIB-0272

Emergency Exit, Red, 12 x 3 5-309-2010

EMERGENCY EXIT

Running Man, 12 x 6

NSN 4240-00-NIB-0274

Fire Extinguisher, 6 x 12

NSN 4240-00-NIB-0275

EXIT, 12 x 9

NSN 4240-00-NIB-0303

Time Delayed Door, 9 x 12

NSN 4240-00-NIB-0304

In Case of Fire, 9 x 12

NSN 4240-00-NIB-0305

PRESS

BAR

Alarm Will Sound

TIME-DELAYED EXIT DOOR

WAIT

PUSH

DOOR

OPEN

In case of fire

Do not use elevator

Use the EXIT stairs

CUSTOM PVC SIGNS

Custom PVC Sign , 8 x 8

NSN 4240-00-NIB-0298

YOUR

DESIGN

HERE

Custom PVC Sign on White Vinyl, 8 x 8

NSN 4240-00-NIB-0302

YOUR

DESIGN

HERE

Custom PVC Sign, 9 x 12

NSN 4240-00-NIB-0306

YOUR

DESIGN

HERE

NEW Photoluminescent Products

CUSTOM SIGNS

For more information, contact Bryan Heeb at 859-445-1677 or bryan.heeb@cincyblind.org

Semi-Rigid Tape Strip for Stairs, Yellow/Green, 47” x 1”

4240-00-NIB-3220

2018 INTERNATIONAL BUILDING CODE

Section 1025: Luminous Egress Path Markings

1025.1 General.

Approved luminous egress path markings delineating the exit path shall be provided in high-rise buildings of Group A, B, E, I-1, M or R-1 occupancies in accordance with this section.

Exception: Luminous egress path markings shall not be required on the level of exit discharge in lobbies that serve as part of the exit path in accordance with Section 1028.1, Exception 1.

1025.2 Markings within exit components.

Egress path markings shall be provided in interior exit stairways, interior exit ramps and exit passageways, in accordance with Sections 1025.2.1 through 1025.2.6.

1025.2.1 Steps

A solid and continuous stripe shall be applied to the horizontal leading edge of each step and shall extend for the full length of the step. Outlining stripes shall have a minimum horizontal width of 1 inch (25 mm) and a maximum width of 2 inches (51 mm). The leading edge of the strip shall be placed not more than 1/₂ inch (12.7 mm) from the leading edge of the step and the stripe shall not overlap the leading edge of the step by not more than 1/₂ inch (12.7 mm) down the vertical face of the step.

Exception: The minimum width of 1 inch (25 mm) shall not apply to outlining stripes listed in accordance with UL 1994.

1025.2.2 Landings.

The leading edge of landings shall be marked with a stripe consistent with the dimensional requirements for steps.

Door Knob Locator Ring, 5.5” or 4.5”, 5 Per Pack

(5.5”) 4240-00-NIB-3232

(4.5”) 4240-00-NIB-3233

PHOTOLUMINESCENT EGRESS PRODUCTS

Photoluminescent Tapes

TAPES

Illuminate your railings, door openings, floors and other items including: apparatus, ladder beams and more with our photoluminescent adhesive tape. This tape will glow for several hours when fully charged. Tape has been UL tested to exceed ASTM E2072/3 per UL 1994. Meets IBC/IFC and NFPA Standards. Photoluminescent multipurpose adhesive tape with directional arrows. Illuminates exits and escape routes to safely direct people if the lights go out. Can be charged by any light source (sun, artificial light, low light). Will illuminate surroundings for several hours when fully charged.

Can withstand high temperatures. May be re-charged repeatedly. Available in 25’ and 50’ lengths.

HIGHLIGHTS:

Made with advanced photoluminescent technology™ using 3M® industrial grade adhesive.

• Durable, designed to withstand high temperatures

• Can be charged by any light source (sun, artificial light, low light) & will recharge indefinitely

• Laboratory tested to emit light up to 30 hours* when fully charged

• UL tested to exceed ASTM E2072 standard for photoluminescent (phosphorescent) safety markings

Available in 25’ & 50’ Lengths

(25’) NSN 4240-00-NIB-0244

(50’) NSN 4240-00-NIB-0245

With Directional Arrows, Available in 25’ & 50’ Lengths

(25’) NSN 4240-00-NIB-0246

(50’) NSN 4240-00-NIB-0247

Grip Wrap Available in 5’ & 10’ Lengths

(5’) NSN 4240-00-NIB-0237

(10’) NSN 4240-00-NIB-0238

Helmet Band:

Track firefighters and increase safety in smoky or dark environments.

NSN 4240-00-NIB-0248

Customizable Adhesive Label 6 3/₈ x 3 1/₂ :

Quickly and easily identify individual firefighters in smoky conditions.

NSN 4240-00-NIB-0276

Photoluminescent Products for First Responders

FIRST RESPONDERS

Help keep your first responders safe with our photoluminescent safety products. These products use our advanced photoluminescent technology to keep your first responders visible in dark or smoky conditions.

Cost Savings Summary

ASSUMPTIONS

EXIT SIGN ENERGY USE BY THE NUMBERS

Annual Carbon

Dioxide (CO2) Pollution

0 Pounds

72 Pounds

230 Pounds

574 Pounds

Exit Sign Lighting Technology

Our Signs

LED

Fluorescent/CFL

Incandescent

Annual Energy Use

0 kWh

44 kWh

140 kWh

350 kWh

Annual Energy Costs

$0

$4

$11

$28

Lamp Service Life

Not Applicable

10+ Years

10.8 Months

2.8 Months

Table from www.energystar.gov and modified to include our products.

Annual Energy Use and Costs Our Signs vs. Traditional/LED Exit Signs

$50

$40

$30

$20

$10

$ 0

350 kWh

140 kWh

44 kWh CABVI LED Fluorescent/CFL Incandescent

ENERGY USE

EN

ER

G Y

CO

ST

S

Annual Carbon Dioxide (CO2) Pollution Our Signs vs. Traditional/LED Exit Signs

CABVI LED Fluorescent/CFL Incandescent

ENERGY USE

PO

U

N D

S

It is widely believed that it costs between $200 and $500 for the sign cost and installation of a traditional or LED exit sign. For purposes of our analysis we have chosen costs in the low range at $280.

We have estimated the annual operating cost of LED, fluorescent and incandescent signs to be $57, $71 and $88 respectively. Our exit sign has no annual operating costs. Our analysis includes replacing each LED exit sign when they go bad at a cost of $40 ($30 for sign and $10 for labor).

In our analysis of existing locations, we have increased the cost of installation by $10 to remove the existing exit sign and cap the electricity.

Monthly inspections: According to NFPA101, electric exit signs must undergo a 30-second test every month.

Yearly inspections: NFPA101 also requires that electric exit signs simulate being on battery backup for 90 minutes every year.

NO ANNUAL

TESTING

REQUIRED!

ANNUAL COST SAVINGS OF $50 - $85 DOLLARS PER YEAR PER SIGN!

IncandescentFluorescentLEDCABVI

Install Sign Cost Labor

Annual Cost Batteries Bulbs Periodic Testing Electricity Replacement Sign ($30 ea x 20%) Replacement Labor ($10 ea x 20%)

$80 $10 $90

$0

$30 $250 $280

$15

$30 $4 $6

$2

$57

$25 $250 $275

$15 $15 $30 $11

$71

$20 $250 $270

$15 $15 $30 $28

$88

15 YEAR SAVINGS

with CABVI Exit Signs

$15M

$10M

$5M

CABVI

vs. LED

CABVI

vs. Fluorescent

CABVI

vs. Incandescent

New Construction Existing Construction

Cost Savings Summary

$7-$14+

MILLION

DOLLAR

SAVINGS

PER 10,000

SIGNS

CABVI SAFETY EXIT SIGN SAVINGS PER 10,000 SIGNS

CABVI vs. IncandescentCABVI vs. FluorescentCABVI vs. LED

New Construction Immediate Install Savings 15 Year Savings

Existing Locations Initial Investment Return on Investment Total Savings (15 years) Payback in Years Internal Rate of Return

$1,500,000 $10,050,000

$1,500,000 570%

$7,050,000 2.6

38%

$1,450,000 $12,100,000

$1,500,000 710%

$9,150,000 2.1

47%

$1,400,000 $14,600,000

$1,500,000 880%

$11,700,000 1.7

59%

Photoluminescent Product Numbers

Adhesive Tape, 1 1/4” x 25’ Adhesive Tape, 1 1/4” x 50’ Adhesive Tape with Directional Arrows, 1 1/4” x 25’ Adhesive Tape with Directional Arrows, 1 1/4” x 50’ 5.5” Door Knob Locator Ring, 5 Per Pack 4.5” Door Knob Locator Ring, 5 Per Pack Semi-Rigid Tape Strip for Stairs, 1” x 42”

4240-00-NIB-0244

4240-00-NIB-0245

4240-00-NIB-0246

4240-00-NIB-0247

3-309-DK02-5

3-309-DK01-5

3-309-SN01

Photoluminescent Tapes & Egress Products

50’ Silver Composite Metal Exit Sign with Frame, Post Mount and Kit, One-Sided 50’ Silver Composite Metal Exit Sign with Frame, Post Mount and Kit, Two-Sided 50’ Silver Composite Metal Exit Sign with Frame, Wall Mount, One-Sided 50’ Silver Composite Metal Exit Sign, No Frame, No Mount, One-Sided 50’ Clear Exit Sign with Universal Wall/Ceiling Mounting Kit, One-Sided 50’ Mirrored Exit Sign with Universal Wall/Ceiling Mounting Kit, One-Sided 50’ Mirrored Exit Sign, Double-Sided Conversion, No Frame, No Mount (to be used with item # 4240-00-NIB-0270) 50’ Green Composite Metal Exit Sign, No Frame, No Mount, One-Sided 50’ Red Composite Metal Exit Sign, No Frame, No Mount, One-Sided 50’ White Composite Metal Exit Sign, No Frame, No Mount, One-Sided 100’ Silver Composite Metal Exit Sign, No Frame, No Mount, One-Sided 100’ Red Composite Metal Exit Sign, No Frame, No Mount, One-Sided 100’ Green Composite Metal Exit Sign, No Frame, No Mount, One-Sided 100’ White Composite Metal Exit Sign, No Frame, No Mount, One-Sided 100’ Custom Color Composite Metal Exit Sign, No Frame, No Mount, One-Sided

4240-00-NIB-0240

4240-00-NIB-0241

4240-00-NIB-0242

4240-00-NIB-0243

4240-00-NIB-0269

4240-00-NIB-0270

4240-00-NIB-0271

5-309-1602PMG2S

6-309-1602PMR

6-309-1602PMW

6-309-1602PM-100

6-309-1601PMR-100

6-309-1602PMG-100

6-309-1602PMW-100

6-309-1602PMC-100

Photoluminescent Exit Signs

Photoluminescent Adhesive Label, “Standpipe”, 3 x 8 Photoluminescent Adhesive Label, “Emergency Exit”, Green, 12 x 3 Photoluminescent Adhesive Label, “Emergency Exit”, Red, 12 x 3 Photoluminescent PVC Sign, Running Man with Directional Arrow, 12 x 6, Bottom Right Photoluminescent PVC Sign, Fire Extinguisher, 6 x 12 Photoluminescent PVC Sign, “Floor 1” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 2” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 3” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 4” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 5” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 6” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 7” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 8” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 9” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, “Floor 10” Stairwell Identifier, 8 x 8 Photoluminescent PVC Sign, Side Directional Arrow, 8 x 8 Photoluminescent PVC Sign, Corner Directional Arrow, 8 x 8 Photoluminescent PVC Sign, “Not an Exit”, 8 x 8 Photoluminescent PVC Sign, EXIT Left, 8 x 8 Photoluminescent PVC Sign, EXIT Right, 8 x 8 Photoluminescent PVC Sign, Stairs, 8 x 8 Photoluminescent PVC Sign, Custom Printed, 8 x 8 PVC Sign, “Door Remain Unlocked”, 8 x 8 PVC Sign, “Fire Door Keep Closed”, 8 x 8 PVC Sign, “No Smoking”, 8 x 8 PVC Sign, Custom Printed, 8 x 8 Photoluminescent PVC Sign, EXIT, 12 x 9 Photoluminescent PVC Sign, “Time Delayed Door”, 9 x 12 Photoluminescent PVC Sign, “In Case of Fire”, 9 x 12 Photoluminescent PVC Sign, Custom Printed, 9 x 12

4240-00-NIB-0272

4240-00-NIB-0273

5-309-2010

4240-00-NIB-0274

4240-00-NIB-0275

4240-00-NIB-0282

4240-00-NIB-0283

4240-00-NIB-0284

4240-00-NIB-0285

4240-00-NIB-0286

4240-00-NIB-0287

4240-00-NIB-0288

4240-00-NIB-0289

4240-00-NIB-0290

4240-00-NIB-0291

4240-00-NIB-0292

4240-00-NIB-0293

4240-00-NIB-0294

4240-00-NIB-0295

4240-00-NIB-0296

4240-00-NIB-0297

4240-00-NIB-0298

4240-00-NIB-0299

4240-00-NIB-0300

4240-00-NIB-0301

4240-00-NIB-0302

4240-00-NIB-0303

4240-00-NIB-0304

4240-00-NIB-0305

4240-00-NIB-0306

Safety Signs

ITEM NAME PAGE NUMBERITEM NUMBER

First Responders

Grip Wrap 5’ Grip Wrap 10’ Helmet Band Label, Custom, SBCA ID, Adhesive Back, Photoluminescent SCBA ID Tag, Metal

4240-00-NIB-0237

4240-00-NIB-0238

4240-00-NIB-0248

4240-00-NIB-0276

4240-00-NIB-0239

Reference Letter

The Honorable Stephen T. Ayers Architect of the Capitol SB-15, U.S. Capitol Washington, DC 20515

Dear Mr. Ayers, Recent incidents at federal buildings, including the U.S. Capitol Complex, have been a sobering reminder of the unique challenges we face as we work to ensure the safety and security of the millions of Americans who visit and work in federal government buildings every day.

Effective signage to guide people to safety is just one component of sound emergency preparedness.

I write to bring to your attention a new, state-of-the-art technology that I believe may provide a cost-effective solution to some of these unique safety challenges at federal buildings.

Photoluminescent technology may be used in the form of signage, such as exit signs for office buildings with complex architectural layouts. These photoluminescent signs offer several advantages over traditional signs because they do not require electricity to operate.

In the event of an emergency, people rely on exit signs to guide them to safety. However, the vast majority of traditional exit signs require electricity to operate. If a natural disaster, terrorist attack or power outage were to occur, a federal building’s electricity supply could be compromised, rendering traditional electric signs, useless, jeopardizing the safety and security of all occupants.

Moreover, the electricity required to operate traditional electric safety signs increases building operational costs through higher electricity consumption.

Reports from Energystar.gov indicate that this technology is more energy-efficient and less costly than the old electric and LED signs.

As Energystar.gov indicates, Photoluminescent exit signs are a potential cost-saving alternative to the traditional signs in the following ways:

• Photoluminescent signs require no back-up batteries

• Photoluminescent signs require no light bulbs to replace

• Photoluminescent signs require no electricity

• Photoluminescent signs require no periodic testing

Because of these differences, photoluminescent technology can offer substantial cost savings. As we look for new and improved ways to ensure the safety and security of the people who visit and work in federal buildings in these dangerous times, I respectfully request that you give the use of photoluminescent exit and safety signs every full and fair consideration in accordance with all applicable laws and regulations.

This innovative technology has the potential to save lives while saving the taxpayers money. As such, I believe it is worthy of consideration as a viable alternative to the electric signs.

Thank you in advance for your consideration and should you require any additional information, please do not hesitate to reach out to Chris Hess in my office at Chris.Hess@mail.house.gov or 202-225-2216. Additionally, please feel free to make this correspondence part of any public record.

Sincerely, Steve Chabot Member of Congress

Brad Wenstrup Member of Congress

ID Credit #1.1

Innovation in Design:

Significant Environmental Benefits

MR Credit #4

Materials and Resources:

Recycled Content

EA Credit #1

Energy and Atmosphere:

Optimizing Energy Performance

LEED Certified

To qualify for this LEED V2.2 Credit [worth up to 10 points] a building project must demonstrate improvement in the proposed building energy performance compared to a baseline criteria specified in ASHRAE/IESNA Standard 90.1, or comply with prescriptive measures of ASHRAE ‘Advanced Energy Design Guide for Small Office Buildings’, or comply with the ‘Basis Criteria and Prescriptive Measures’ of the Advanced Buildings Benchmark.

More points are awarded to building projects using less energy than “baseline” guidelines prescribed by ASHRAE or the Advanced Buildings Benchmark.

With respect to exit signs, these guidelines are formulated on the basis of installing modern LED exit signs which use about 5 watts of power. Although the impact of a few exit signs using 5 watts is not significant, larger facilities can employ thousands of exit signs in high and low applications. Recognizing that electrically powered exit signs must be energized 24 hours/day x 365 days/year, a typical large building project with 500 LED exit signs, each using 5 watts of power, burns nearly 22,000 kwh of electricity annually, costing about $3,000 at $.14/kwh.

Since our Photoluminescent Exit Signs are charged from nearby area lighting and require no direct power, there is no related electricity cost. Consequently, our Photoluminescent Exit Signs will positively contribute to the calculations that determine the energy efficiency of a building project. Depending upon the number of exit signs in your building, this additional energy savings can be significant in obtaining points toward EA Credit #1.

There are two avenues available to obtain Innovation in Design points. Using our Photoluminescent Exit Signs works best with the avenue whereby the project team demonstrates a comprehensive approach toward employing a product or technology that has significant environmental benefits not addressed or credited in other LEED categories. The comprehensive approach targets optimizing the benefits and trade-offs of an innovation proposal throughout its life cycle phases: design, procurement, construction, operational and decommissioning.

The advantages of our Photoluminescent Exit Signs span all the life cycle phases with the following environmental benefits:

• Fewer Building Materials Required

• Energy Efficient

• High Percentage of Recycled and Recyclable Materials

• No Hazardous Materials or Wastes

• Longer Lifespan

• Less Maintenance

MR Credit #4 requires that 10% of the dollar value of permanently installed project materials consist of recycled content. The recycled content value of a material is determined by its adjusted recycled weight [=100% post consumer component weight + 50% pre-consumer component weight] multiplied by the total dollar value of the assembly.

Since several of our Photoluminescent Exit Signs are made primarily of metal with a high recycled content, these exit signs will contribute greatly toward this credit.

As an example, for a typical $89.95 aluminum wall mount Photoluminescent Exit Sign that weighs approx. 12.8 oz:

• Post-consumer recycled content component weight = 5.9 oz

• Pre-consumer recycled content component weight = 2.5 oz

• Non-recycled component weight = 4.4 ounces

Recycled content value = [100% x [5.9/12.8 + .5 x 2.5/12.8]] x $89.95 of one exit sign = $49

Compliance Certification

See General Information for Exit Signs, Self-luminous and Photoluminescent

CINCINNATI ASSOCIATION FOR THE BLIND AND VISUALLY IMPAIRED

2045 Gilbert Ave Cincinnati, OH 45202 USA

Photoluminescent exit sign, Models EG-Exit-CLR-BE, EG-Exit-CLR-BL, EG-Exit-CLR-GR, EG-Exit-CLR-RD, EG-Exit-PL-BE, EG-Exit-PL-BL, EG-Exit-PL-GR, EG-Exit-PL-RD, EG-Exit-BE-PL, EG-Exit-BL-PL, EG-Exit-GN-PL, EG-Exit-GR-PL, EG-Exit-RD-PL, EG-Exit-M-BE, EG-Exit-M-BL, EG-Exit-M-GR and EG-Exit-M-RD, rated viewing distance 50 ft, minimum 5ft-c unfiltered fluorescent, metal halide, mercury vapor, or LED external illumination, Suitable for Floor Proximity Installation.

The appearance of a company’s name or product in this database does not in itself assure that products so identified have been manufactured under UL’s Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL’s Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions:

1. The Guide Information, Assembles, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings).

2. The statement “Reprinted from the Online Certifications Directory with permission from UL” must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: “© 2016 UL LLC”.

Exit Signs, Self-luminous and Photoluminescent

FWBX.E483541

Exit Signs, Self-luminous and Photoluminescent

E483541

All products in this catalog are assembled and/or packaged at the Cincinnati Association for the Blind & Visually Impaired.

Cincinnati Association for the Blind & Visually Impaired is a 501(c)(3) not-for-profit organization.

Our mission is to empower people of Greater Cincinnati who are blind or visually impaired with opportunities to seek independence, which includes providing employment opportunities to people who are visually impaired or legally blind since 1911. With the national average of unemployment for people who are legally blind at nearly 70%, we are passionate about providing solutions that put people and ideas to work.

BRINGING SAFETY TO LIGHT.

File details come from the government source that posted it. Updated .