29_ITEM 01.3-15_ADD 02_02700SF502.pdf
PDF 414 KB Posted
- Attached to
- F-35 THREE BAY SPECIALIZED HANGAR Federal contract opportunity
- Solicitation number
- W50S9F-22-B-0001
- Issued by
- Department of the Army National Guard
About this file
This federal contract opportunity is for an unrestricted invitation for bid to construct a new three-bay specialized hangar at Dane County Regional Airport-Truax Field in Madison, Wisconsin. The project scope includes demolishing an existing 19,875 square foot building and constructing a new 31,000 square foot three-bay hangar with administrative and shop spaces to accommodate fuel cell operations, indoor wash requirements, squadron-level surface coating operations, and weapons load training. The facility will also require a lightning protection system, fall protection, and an Advantor security system.
The solicitation will result in a single construction contract with a base award for the hangar construction and two options. Option one is for a paint/mix addition and option two is for aircraft-rated pavement. The North American Industry Classification code is 236220 with a size standard of $39.5 million. The contract duration is 550 days from notice to proceed. Interested contractors must register in SAM and check the website periodically for amendments. The bid opening will be conducted in accordance with FAR Subpart 14.4 and DFARS Subpart 214.4. The agency is the Department of the Army National Guard.
View the file
Other files for this federal contract opportunity
Show all 50
F-35 THREE BAY SPECIALIZED HANGAR has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PARAPET
FRAMING
C12 GIRT AND
W10 BRACKET
1'-10"
W BEAM
(REFER PLAN)
W COL
(REFER PLAN)
3/8" PL W/ (3) 3/4"
DIA A325-N BOLTS
A2 S-007
HSS12X12 EXTEND
(BEYOND)
PROVIDE END CAP
C12 (REFER ELEV)
W BEAM
(REFER PLAN)
W COL
(REFER PLAN)
3/8" PL W/ (4) 3/4"
DIA A325-N BOLTS
1'-10"
HSS12
TO
HSS12
HSS12X12
(REFER ELEV)
PROVIDE ACCESS TO
CONNX AND CAP AFTER
ASSEMBLY
HSS12X2 PARAPET
SUPPORT (BEYOND)
SIM TO A3/S-007
SLOPE
4' -0
L2-1/2x2-1/2x1/4 KICKER
STEEL BEAM (REFER PLAN)
1/4" PLATE w/ (1)
3/4" DIA A325-N
BOLT
STEEL DECK
STEEL BEAM
(REFER PLAN)
DECK EDGE
1/4 2@12
6"
L2-1/2x2-1/2x1/4 KICKER
STEEL BEAM (REFER PLAN)
1/4" PLATE w/ (1)
3/4" DIA A325-N
BOLT
STEEL DECK
ELEV. VARIES
L2-1/2x2-1/2x1/4 KICKER
STEEL BEAM (REFER PLAN)
1/4" PLATE w/ (1) 3/4"
DIA A325-N BOLT
STEEL DECK
STEEL BEAM
(REFER PLAN)
WP
1/4" BENT PLATE
M
REF ARCH1'-10"
MANUFACTURED ALUM
CANOPY ASSEMBLY
(REF ARCH)
GC TO COORD SIZE
AND LOCATION OF
BOLT PER ALUM
CANOPY MFG
BOT OF CANOPY CAP
REF ARCH
1" G
AP
5' -0
3"
COPE BOT OF HSS6X6 AS REQ'D
1/4
W14 (REF ELEV)
C12 (REF ELEV)
L4X4X5/16X0'-8"
2 MIN
2 MIN
1/4 1/4
1/4
HSS6X6
(REF ELEV)
C12 (REF ELEV)
HSS6X6X1/4 GC TO COORD
LOCATION OF HSS WITH
ALUM CANOPY MFG
HSS6X6X1/4 EXTENSION W/ CAP TYP
1/4
TYP
A
REF ARCH3"11"
114'-5"
EXT FACE OF STUD
BOT OF CANOPY CAP
REF ARCH
TOP OF POST
6" M
IN
HSS6X6X1/4 POST GC TO
COORD LOCATION OF POST
WITH ALUM CANOPY MFG
MANUFACTURED ALUM
CANOPY ASSEMBLY
(REF ARCH)
GC TO COORD SIZE
AND LOCATION OF
BOLT PER ALUM
CANOPY MFG
POST CAP
2" 11" 2"
6"
L6X4X3/8X1'-3" LLV EACH SIDE OF HSS W/
3/4" DIA THRU BOLT AND SLOTTED HOLE
13/16"X2 3/4"
3/16 3/16
L2-1/2x2-1/2x1/4 KICKER
1/4" PLATE W/ (1) 3/4"
DIA A325-N BOLT TYP
3/16 3/16
TYP
HSS6X6X1/4 EXTENSION W/ CAP TYP
1/4
TYP
DECK EDGE
6"1/4 2@12
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\ich\D o cum ents\M y R evit\02700_Stru_ih ortonXV Z5D
.rvt 6/7/2022 9:10:4 1 A
M
FRAMING DETAILS
SF502
TJD
GMR
GMR
SCALE: 1" = 1'-0"
SECTIOND1 SCALE: 1" = 1'-0"
SECTIOND2
0 6" 1' 2'
1" = 1'-0"
SCALE: 1 1/2" = 1'-0"
SECTIONC2SCALE: 1 1/2" = 1'-0"
SECTIONC1
6" 1'-6"1'0
1 1/2" = 1'-0"
SCALE: 1 1/2" = 1'-0"
SECTIONC3
SCALE: 1" = 1'-0"
SECTIONA1 SCALE: 1" = 1'-0"
SECTIONA3
1 ADDENDUM 2 06/08/2022
W
IS C O NS IN
P R
O F
E
S S I O N A L
E N G
I N E
E R
GENE O.
BROWN
E-47748
OKLAHOMA CITY
OK