29_ITEM 01.3-19_ADD 03_02700A-601.pdf
PDF 216 KB Posted
- Attached to
- F-35 THREE BAY SPECIALIZED HANGAR Federal contract opportunity
- Solicitation number
- W50S9F-22-B-0001
- Issued by
- Department of the Army National Guard
About this file
This document provides details for an unrestricted invitation for bid for the construction of an F-35 three bay specialized hangar. The solicitation requests the construction of a new 31,000 square foot three bay hangar at Dane County Regional Airport - Truax Field in Madison, Wisconsin to support F-35 mission operations such as fuel cell work, indoor washing, and weapons load training. The scope of work includes demolishing an existing 19,875 square foot building and constructing the new hangar along with associated shop and administrative spaces. The hangar bays are to include pre-conditioned aircraft air, 270 VDC aircraft power, fire suppression, and hangar bay HVAC. The project is estimated to cost between $25-100 million and will be registered with the US Green Building Council. The solicitation includes a base bid for construction as well as two options for a paint/mix addition and aircraft rated pavement. The North American Industry Classification code is 236220 with a size standard of $39.5 million. Brand name justification is provided for several products. The bid opening will be conducted according to FAR and DFARS and award will go to the responsive and responsible lowest bidder.
View the file
Other files for this federal contract opportunity
Show all 50
F-35 THREE BAY SPECIALIZED HANGAR has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
9' -0
3' -4
3'
-8
2' -0
TYP NOTE
HEAD
JAMB
SILL
A
D5/A-502 B1&C1/A-505 B3/A-502
7' -0
T
T
TTT
T
T
6'-0" EQEQ
11'-3"
9' -0
2' -0
3'
-8
3' -4
9'-1"
EQ EQ EQ
TYP NOTE
HEAD
JAMB
SILL
B
D5/A-502 C1&B2/A-505 B3/A-502
TTT
GROUND FLOOR
100'-0"
9' -0
EQEQEQ0"13/128" 6'-0" EQ
TYP NOTE
HEAD
JAMB
SILL
C
A4/A-501 A4/A-501 B3/A-502
TT
T T T
TT
17'-11 7/8"18'-0"
7' -0
"TT
2' -0
3'
-8
3' -4
4'-0"
SUNSHADE
PER
ELEVATIONS
4' -0
3'
-4
TYP NOTE
HEAD
JAMB
SILL
D
B4/A-500 B3/A-500 B2/A-500
1/
2"
1/ 2"
1' -4
5'-5"
4' -0
3'
-4
TYP NOTE
HEAD
JAMB
SILL
E
B4/A-500 B3/A-500 B2/A-500
9' -0
3' -4
3'
-8
2' -0
TYP NOTE
HEAD
JAMB
SILL
F
A1/A-500 A3/A-505 B3/A-502
7' -0
T
T
T
T
T
T T
EQ 3'-0" EQ
8'-0"
9' -0
8'-0"
EQ 6'-0" EQ
2' -0
3'
-8
3' -4
TYP NOTE
HEAD
JAMB
SILL
G
A1/A-500 B2/A-505 B1/A-500
T
T
T
T
T
7' -0
"T T
GROUND FLOOR
100'-0"
TYP NOTE
HEAD
JAMB
SILL
H
A1/A-500 B3/A-500 B1/A-500
T TT
T T
8'-0"
EQ 6'-0" EQ
9' -0
2' -0
3'
-8
3' -4
7' -0
"T T
7' -2
3'-8"
TYP NOTE
HEAD
JAMB
SILL
I
B2/A-501 B3/A-501 B4/A-501
T
PRIVACY FILM -
REFER TO SHEET
A-402 / C4
6 1/4" 2'-11 3/4" 2"
7' -2
6 1/4"
31'-8 3/8"
2" EQ EQ EQ EQ EQ EQ EQ EQ EQ
TYP NOTE
HEAD
JAMB
SILL
J
B2/A-501 B3/A-501 B4/A-501
T T T T T T T T T
PRIVACY FILM - REFER TO
SHEET A-402 / B1
GROUND FLOOR
100'-0"
4' -0
3'
-4
TYP NOTE
HEAD
JAMB
SILL
K
A4/A-500 A3/A-500 A2/A-500
1, 3
FIRE SHUTTER ON
HANGAR SIDE
GENERAL NOTES
A. ALL FRAME DIMENSIONS ARE NOMINAL ROUGH
OPENING AND CONTRACTOR SHALL COORDINATE
ACTUAL OPENING SIZES WITH RESPECT TO
REQUIRED SHIM SPACE AND ADJACENT MATERIAL.
B. NO EXPOSED FASTENERS SHALL BE ALLOWED IN
ALUMINUM CURTAINWALL FRAMES.
C. PROVIDE MINIMAL EXPANDING FOAM AT PERIMETER
SHIM CAVITY.
D. REFER TO SPECIFICATION SECTION 087100-GLAZING
FOR GLAZING TYPES.
E. TEMPERED GLAZING IS INDICATED WITH A "T".
F. EXTERIOR GLAZING SHALL BE INSULATED.
G. INTERIOR GLAZING SHALL BE NON-INSULATED.
SHEET KEYNOTES
1. CURTAINWALL SYSTEM: 2" X 4 - 1/2" SCREW SPLINE
OR SHEAR BLOCK UNLESS NOTED OTHERWISE.
2. BUTT GLAZED VERTICAL JOINT WITH 2" - 4 - 1/2"
EXTERIOR FRAMING SYSTEM UNLESS NOTED
OTHERWISE.
3. GLAZING IN HANGAR SHALL BE INSULATED.
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\w fj\ D ocum e nts\0270 0_Arch_ W
Jim en ezKN
JQ
U
.rvt
6/14 /2022 5: 12:16 PM
WINDOW ELEVATIONS
A-601
JMI
GAZ
MP
1 ADDENDUM 3 06/14/2022
1 1 1
1 1 1 1 1
1 1 1
W
IS C O NS IN
A R C H I T E C T
JASON T.
HOLUBY
A-13101
OKLAHOMA CITY
OK
| Sheets |
| A-002 - PARTITION TYPES |
| A-103 - PARTIAL FLOOR PLAN - SECTOR ONE |
| A-104 - PARTIAL FLOOR PLAN - SECTOR TWO |
| A-306 - WALL SECTIONS |
| A-307 - WALL SECTIONS |
| A-500 - DETAILS |
| A-501 - DETAILS |
| A-505 - PLAN DETAILS |
| A-510 - ISOMETRIC EXPANSION JOINT |
| A-511 - ISOMETRIC EXPANSION JOINT |
| A-600 - DOOR SCHEDULE |
| A-601 - WINDOW ELEVATIONS |
| A-602 - ROOM FINISH SCHEDULE & FINISH MATERIALS SCHEDULE |
| A-701 - COMPOSITE FLOOR PLAN, ROOF PLAN, ELEVATIONS, WALL SECTION & DETAILS - BID OPTION 1 |
| A-702 - FLOOR FINISH PLAN, ROOM FINISH SCHEDULE- BID OPTION 1 |
| G-002 - SHEET INDEX |
File details come from the government source that posted it. Updated .