49_ITEM 01.3-35_ADD 02_02700ET101.pdf
PDF 718 KB Posted
- Attached to
- F-35 THREE BAY SPECIALIZED HANGAR Federal contract opportunity
- Solicitation number
- W50S9F-22-B-0001
- Issued by
- Department of the Army National Guard
About this file
This document provides details for an unrestricted Invitation for Bid for construction services. The bid is for a project to construct a new three-bay hangar at Dane County Regional Airport - Truax Field in Madison, Wisconsin to support operations for the F-35 aircraft. Services required include demolishing an existing building and constructing a 31,000 square foot hangar with three bays, administrative and shop spaces, a lightning protection system, and an Advantor security system. The contract value is estimated between $25-100 million. The bid includes options for adding a paint/mix addition and aircraft rated pavement. The pre-bid conference will be held on-site with the bid opening following standard FAR and DFARS procedures. The response deadline is not provided, but the contract duration is listed as 550 days. The solicitation is designated unrestricted with a HubZone preference and requires registration on SAM.gov to access the full bid package.
View the file
Other files for this federal contract opportunity
Show all 50
F-35 THREE BAY SPECIALIZED HANGAR has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
108110
111 109
B
B
C
C
E
E
F
F
G
G
J
J
D
D
K
K
L
L
M
M
H
H
48"
72" 72"
48"
48"
48"
WAP
WAP
WAP
WAP
WAP
WAP
WAP
MATCHLINE
SEE A1 /
ET102
MATCHLINE
SEE A1 /
ET102
TVTV
1 1
FB
FB
FB 2
TECHNOLOGY SCOPE RESPONSIBILITY MATRIX
ITEM SHOWN ON FURNISHED BY INSTALLED BY NOTES
FLOORBOX ROUGH-IN, INCLUDING FLOOR BOXES AND CONDUITS
TECHNOLOGY SYSTEMS ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS, CONDUIT AND SLEEVES
CABLE TRAY, INCLUDING ALL REQUIRED SUPPORT HARDWARE AND FITTINGS
EQUIPMENT ROOM FITTINGS (PER SPECIFICATION SECTION 271100)
EQUIPMENT ROOM POWER RECEPTACLES
GROUND BARS (TMGB, TGB) AND ELECTRICAL SERVICE BONDING
GROUNDING OF CABLE TRY AND EQUIPMENT ROOM COMPONENTS
BACKBONE CABLING, TERMINATION COMPONENTS (e.g. WALL-FIELDS), TERMINATION, TESTING AND LABELING
PATCH PANELS
TELECOMMUNICATIONS OUTLET (TO) FACEPLATES AND JACKS
HORIZONTAL CABLING, TERMINATIONS, TESTING AND LABELING
FLOOR BOX AND TELECOMMUNICATION OUTLET (TO) ASSOCIATED POWER RECEPTACLES
EQUIPMENT ROOM PLYWOOD WALL COVERINGS
PA SYSTEM COMPONENTS (SPEAKERS/HORNS, VOLUME CONTROLS) AND CABLING
PA SYSTEM ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS AND CONDUIT
TV ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS AND CONDUIT
INFORMATION DISPLAY AND TV LOCATION BLOCKING FOR DISPLAY MOUNT ATTACHMENT/ SUPPORT
TV OUTLETS, MOUNTS, DISPLAYS AND CABLING
TV SERVICE, DISTRIBUTION EQUIPMENT AND RECEIVERS
SECURITY SYSTEMS (ACS, VSS) ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS AND CONDUIT ACS FIELD DEVICES (e.g. CARD READERS, STATUS SENSORS, REX) AND CABLING ACS DOOR HARDWARE INCLUDING ELECTRIC STRIKES, MAGNETIC LOCKS AND ASSOCIATED POWER SUPPLIES
VSS HEAD-END, CAMERAS, MOUNTS AND CABLING
TV SYSTEM HEAD-END COMPONENTS AND MONITOR INTERFACES
EP AND ET SERIES EC EC 1
ET SERIES EC EC 2
T-SERIES EC OR TC EC OR TC 3
ET SERIES TC TC
EP SERIES EC EC
EG SERIES EC EC
EG SERIES TC TC
ET SERIES TC TC
ET SERIES TC TC
ET SERIES TC TC
N/A OWNER OWNER
EP AND ET SERIES EC EC
ET SERIES GC GC 5
TY SERIES TC TC
TY SERIES EC EC
ET SERIES EC EC
ET SERIES GC GC 6
ET SERIES EC EC
N/A OWNER OWNER
N/A OWNER OWNER
TY SERIES EC EC
TY SERIES ADVANTOR ADVANTOR 8
TY SERIES GC GC/EC/TC/ADVANTOR 7, 8
TY SERIES ADVANTOR ADVANTOR 8, 9
TECHNOLOGY SYSTEMS RESPONSIBILITY MATRIX NOTES:
1. FLOOR BOX LOCATIONS SHALL BE COORDINATED WITH
THE LOCATIONS OF ASSOCIATED MILLWORK AND
FURNITURE.
2. PENETRATIONS THROUGH FLOORS AND FIRE-RATED
WALLS WHERE APPLICABLE SHALL BE FIRESTOPPED IN
A MANNER THAT MAINTAINS THE RATING OF THE
FLOOR OR WALL PENETRATED. REFER TO
ARCHITECTURAL SPECIFICATIONS.
3. CABLE TRAY INDICATED ON DRAWINGS IS SHOWN FOR
INTENT, AND THE INSTALLATION OF THE CABLE TRAY
SHALL BE COORDINATED WITH OTHER TRADES
(MECHANICAL & PLUMBING).
4. LOCATIONS OF TECHNOLOGY SYSTEMS ROUGH-IN
SHALL BE COORDINATED WITH ASSOCIATED POWER
RECEPTACLES.
5. PLYWOOD WALL COVERINGS SHALL BE AS SPECIFIED
IN ARCHITECTURAL SPECIFICATIONS.
6. BLOCKING FOR ALL TV AND IDS (FPD) LOCATIONS
SHALL BE AS SPECIFIED IN ARCHITECTURAL
SPECIFICATIONS OR AS INDICATED ON
ARCHITECTURAL DRAWINGS.
7. CONTRACTOR SHALL COORDINATE THE INSTALLATION
OF ALL ACCESS CONTROL SYSTEM COMPONENTS WITH
DOOR AND DOOR HARDWARE VENDOR.
8. GENERAL CONTRACTOR SHALL SUBCONTRACT TO
ADVANTOR AND COORDINATE ALL IDS AND SECURITY
SYSTEMS.
9. PROVIDE CAMERAS, MOUNTS AND CABLING . GC IS
RESPONSIBLE FOR COORDINATING WITH ADVANTOR
FOR COST .
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021N
N
PROJECT
KEYPLAN
A
PLAN TRUE
C :\U sers\aoo\D o cum ents\M y R evit\02700_Elec_A O genche.rvt
6/7/2022 11:01: 27 AM
TELECOMMUNICATION PLAN
SECTOR ONE
ET101
WCM
GPN
GPN
SCALE: 1/8" = 1'-0"
TELECOMMUNICATION PLAN SECTOR ONEA1
0 4' 8' 16'
1/8" = 1'-0"
ROOM SCHEDULE
Name Number
WEAPONS TRAINING 101
VEST. 102
SHARED OFFICE 103
FUEL OPEN OFFICE 104
VEST. 105
CORR. 106
CLASSROOM 107
OFFICE 108
RR W 109
WING WEAPONS MGR 110
RR M 111
FUEL SUPERVISOR 112
BREAK/ TRAINING 113
VEST. 114
OFFICE 115
VINYL OPEN OFFICE 116
MOTHER'S ROOM 117A
JAN 117B
FUEL MAINT. GENERAL STORAGE 118
FUEL CELL 119
VEST 120A
CORR. 120B
ELEC. 121
FUEL 122
WASH 123
MECH 124
FIRE 125
TOOLS 126
VEST 127
WASH BAY 128
CLEAN M RR 130
CLEAN M LR 131
CLEAN SHOWER M 132
DIRTY SHOWER M 133
DIRTY LR M 134
DIRTY SHOWER M 135
CLEAN W RR 136
CLEAN W LR 137
CLEAN SHOWER W 138
DIRTY LR W 139
DIRTY SHOWER W 140
PAINT/SAND/MIX 140
DIRTY RR UNISEX 141
DIRTY VEST. 142
MASK WASHING 143
PAINT/SAND/MIX 144
ELECT 145
COMM. 146
GENERAL NOTES
A. ANY DIMENSIONS SHOWN ON THESE DRAWINGS
ARE INTENDED TO PROVIDE A GENERAL LOCATION
AS REQUESTED BY THE OWNER. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR CONFIRMING ALL
DIMENSIONS PRIOR TO ROUGH-IN AND
IMMEDIATELY REPORT ANY CONFLICTS WITH THE
OUTLET PLACEMENT TO THE GENERAL
CONTRACTOR.
B. ALL CABLE BUNDLES WILL BE SUPPORTED EVERY
48"-60" OC WITH A J-HOOK OR OTHER APPROVED
PATHWAY DEVICE. REFERENCE SPECIFICATIONS
AND DETAILS FOR ADDITIONAL CABLING PATHWAY
INSTALLATION REQUIREMENTS. CONTRACTOR WHO
VIOLATES THIS REQUIREMENTS WILL BE REQUIRED
TO REPLACE THE AFFECTED CABLE AT THEIR
EXPENSE.
C. PLASTIC TIE WRAPS ARE NOT PERMITTED AT ANY
TIME ON THE INSTALLATION. ALL CABLE ROUGH-IN
AND DRESS-OUT WILL BE WITH HOOK AND LOOP
STRAP ONLY. ALL CABLES BUNDLED WITH PLASTIC
TIE WRAPS SHALL BE IMMEDIATELY REPLACED AT
THE CONTRACTOR'S EXPENSE.
D. DO NOT INSTALL ANY CABLES IN ANY CONDUIT
SLEEVE, STUB UP, OR WALL CAP WITHOUT A
PROTECTIVE BUSHING. CABLES PULLED INTO
UNPROTECTED CONDUITS WILL BE REPLACED AT
THE CONTRACTOR'S EXPENSE. DO NOT INSTALL
ANY CABLING INTO ANY CONDUIT THAT HAS NOT
BEEN CONFIRMED TO BE BLOWN CLEAR.
COORDINATE WITH THE ELECTRICAL CONTRACTOR
PRIOR TO ROUGH IN OF ANY CABLING.
E. ANY CABLING FOUND PAINTED DURING THE
CONSTRUCTION PROCESS WILL BE REPLACED AT
CONTRACTOR'S EXPENSE. CONTRACTOR SHALL
COORDINATE WITH THE GENERAL CONTRACTOR
AND PAINTER TO AVOID CONFLICTS.
F. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
REFERENCE BOTH THE PROJECT DRAWINGS AND
THE PROJECT SPECIFICATIONS. TOGETHER THEY
FORM THE COMPLETE CONTRACT DOCUMENTS.
REFERENCE THE PROJECT SPECIFICATIONS FOR
ALL MATERIALS, EQUIPMENT, AND COMPONENTS
NOT INDICATED ON THE DRAWING SET.
G. ALL CABLING INSTALLED IN AREAS WITH EXPOSED
CEILINGS SHALL BE INSTALLED IN A PROPERLY
SIZED CONDUIT PATHWAY. CONDUIT PATHWAYS
SHALL BE PROVIDED AND INSTALLED BY THE
CONTRACTOR. THE CONDUIT MAY BE PAINTED TO
MATCH CEILING COLOR AS DIRECTED BY THE
CONTRACT DOCUMENTS.
H. CONTRACTOR SHALL BE RESPONSIBLE FOR
STOPPING ALL TECHNOLOGY, TELECOM, SECURITY
AND AUDIO VISUAL CONDUIT PENETRATIONS FROM
WATER AND RODENT INGRESS IN ALL BUILDING
UPON COMPLETION OF THE PROJECT.
SHEET KEYNOTES
1. MOUNT CABLE TRAY 10'-10" AFF TO THE MIDDLE OF
THE CABLE TRAY.
2. FLOOR BOX SHALL HAVE 2 NIPRNET DROPS.ROUTE
1" CONDUIT FROM FLOOR BOX THROUGH THE WALL
CAVITY TO ACCESSIBLE CEILING FOR ROUTING THE
NIPRANETS.