About this file

This is a product specification document for an Isolite CMB Thermoplastic LED Exit Sign and Emergency Combo unit. The document provides detailed technical specifications for a ceiling-mounted emergency lighting fixture featuring two fully adjustable lamp heads that each draw 1.5W and produce 154 lumens per unit. The unit operates on 120/277 VAC with field-selectable inputs and includes a universal mounting canopy compatible with single or double face configurations. The LED array is available in red or green, with quick-fit snap-in installation and field-selectable chevron directional indicators. The unit accommodates a 3.6V nickel cadmium battery providing 90 minutes of run time, with optional remote capacity capability of up to 2.5W through the EB option, supporting up to two Isolite MVH remote heads when the SD self-diagnostics model is selected.

The unit housing is constructed from high-impact, injection-molded flame-retardant thermoplastic and weighs 3.7 pounds, with a temperature operating range from 32°F to 122°F. It is approved for damp locations and meets multiple standards including UL 924, NFPA Life Safety Code 101, NFPA 70-NEC, OSHA, and CEC Title 20 compliance requirements. The specification document includes detailed dimensional information and a lamp spacing table providing center-to-center spacing recommendations for multiple unit installations at mounting heights ranging from 7 to 20 feet, with an optimal aiming angle of 20 degrees from ground. Isolite offers a 5-year limited warranty on the unit, with lamps excluded from warranty coverage. An optional wireguard accessory is available for separate ordering and compatible only with back-mount configurations.

View the file

Other files

File Type Posted
230923 Alerton Direct Digital Control System for HVAC.pdf PDF
TYPE S1 iO-CoviO-Spec-Sheet.pdf PDF
260553-RIB-Identification for Electrical Systems-12-24-2025.pdf PDF
232113-RIB-Hydronic Piping-12-24-2025.pdf PDF
235100-RIB-Breechings, Chimneys, and Stacks-12-24-2025.pdf PDF
262726-RIB-Wiring Devices-12-24-2025.pdf PDF
260505-RIB-Selective Demolition for Electrical-12-24-2025.pdf PDF
CBI GJ Project Manual_VSS_R2.pdf PDF
230523-RIB-General-Duty Valves for HVAC Piping-12-24-2025.pdf PDF
TYPE P2 Metalux-Cruze-Linear-Bay-spec-sheet.pdf PDF
238126.13-RIB-Small-Capacity Split-System Air Conditioners-12-24-2025.pdf PDF
Bid Questions - BCE Response - 05012026.pdf PDF
CBI GJ sign-in.pdf PDF
260519-RIB-Low-Voltage Electrical Power Conductors and Cables-12-24-2025.pdf PDF
230513-RIB-Common Motor Requirements for HVAC Equipment-12-24-2025.pdf PDF
TYPE D3 PrentaLux-CYL6-6-Sustainable-LED-Cylinder-Luminaire-Spec-Sheet.pdf PDF
232123-RIB-Hydronic Pumps-12-24-2025.pdf PDF
235216-RIB-Condensing Boilers-12-24-2025.pdf PDF
265600-RIB-Exterior Lighting-12-24-2025.pdf PDF
TYPE IU Sure-Lites-SLX-Surface-Mount-LED.pdf PDF
221006-RIB-Plumbing Piping Specialties-12-24-2025.pdf PDF
233423-RIB-HVAC Power Ventilators-12-24-2025.pdf PDF
231123-RIB-Facility Natural-Gas Piping-12-24-2025.pdf PDF
265100-RIB-Interior Lighting-12-24-2025.pdf PDF
230719-RIB-HVAC Piping Insulation-12-24-2025.pdf PDF
230593-RIB-Testing, Adjusting, and Balancing for HVAC-12-24-2025.pdf PDF
232114-RIB-Hydronic Specialties-12-24-2025.pdf PDF
220529-RIB-Hangers and Supports for Plumbing Piping and Equipment-12-24-2025.pdf PDF
260923-RIB-Lighting Control Devices-12-24-2025.pdf PDF
260583-RIB-Wiring Connections-12-24-2025.pdf PDF
230800-RIB-Commissioning of HVAC-12-24-2025.pdf PDF
233100-RIB-HVAC Ducts and Casings-12-24-2025.pdf PDF
230553-RIB-Identification for HVAC Piping and Equipment-12-24-2025.pdf PDF
230913-RIB-Instrumentation and Control Devices for HVAC-12-24-2025.pdf PDF
25388-CBI 100% CD w Add1.pdf PDF
230529-RIB-Hangers and Supports for HVAC Piping and Equipment-12-24-2025.pdf PDF
220553-RIB-Identification for Plumbing Piping and Equipment-12-24-2025.pdf PDF
221005-RIB-Plumbing Piping-12-24-2025.pdf PDF
265140-LUT-Luminaires-12-24-2025.pdf PDF
Answers to Questions_IFB REAA 2027-05.pdf PDF
237413-RIB-Packaged Outdoor Central-Station Air-Handling Units-12-24-2025.pdf PDF
TYPE P1 Corelite-Iridium-i3-Suspended-specification-sheet.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMENTS:DATE:

PROJECT

ISOLITE WWW.ISOLITE.COM

ISOLITE HEADQUARTERS 800.888.5483 31 WATERLOO AVENUE, BERWYN, PA 19312

ISOLITE WEST 800.799.5343 3563 SUELDO SUITE M, SAN LUIS OBISPO, CA 93401

D-7.2.3.0-201 REV-24 20250714

SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT NOTIFICATION.

CONTACT ISOLITE FOR UP TO DATE DETAILS.

FEATURES

� Two lamp heads are fully adjustable and draw 1.5W each.
� 154 lumens per unit.
� Universal mounting canopy included for ceiling mounting: universal, single, or

double face.

� Quick-fit, snap-in installation with field selectable chevron directional indicators.
� Long life, high intensity LED array available in red or green.
� Approved for use in damp locations.
� Maintenance free, 3.6V nickel cadmium batteries provide 90 minutes of run time
� Option EB allows up to 2.5W remote capacity. Compatible with up to (2) Isolite

MVH remote heads (must select SD model if SD is chosen here).

� Meets CSA C22.2 No. 141-02.

1. SERIES

ORDERING INFORMATION CMB-EM-R-U-WH-MTEBP-L1

3. LETTER COLOR2. OPERATION

CMB EM

CMB

Thermoplastic LED Exit Sign and Emergency Combo

R Red G Green

EM Ni-Cad Battery Backup U Universal

BLANK = NO OPTION

SD Self-Diagnostics EB Remote Capacity1

4. FACE COUNT

8. OPTIONS

U

MTEBP Universal Mount L1 LED 1.5W

6. MOUNTING

BK Black WH White

5. HOUSING COLOR

MTEBP

7. LAMP SOURCE

SPECIFICATIONS

CONSTRUCTION

� High impact housing designed with injection molded 5VA flame retardant thermoplastic.

ELECTRONICS

� Electronic control circuit and isolation transformer provide current control and circuit protection, ensuring optimum LED efficiency and life.

� 120/277 VAC with field selectable inputs.
� Solid state transfer relay utilized for

reliability.

LETTERS

� 6” high; 0.75” stroke

WEIGHT

� 3.7 lbs

TEMPERATURE RATING

� From 32°F to 122°F

APPROVALS

� UL 924
� NFPA Life Safety Code 101
� NFPA 70-NEC
� OSHA
� Damp Location Listed
� CEC Title 20 Compliant

WARRANTY

� Isolite offers a 5-year limited warranty.

For further details, refer to General Warranty and Obligations in the Isolite manual or on our website. Lamps not warranted

ORDERING NOTES

1. If using the remote capacity option without any remote lamp heads attached, the base unit run time is extended to greater than 2 hours.

ACCESSORIES; ORDER SEPARATELY

� WG-20.0LX19.0WX9.0D = Wireguard, Length: 20”, Width: 19”, Depth: 9”

NOTE: Wireguards only available with Back Mount.

L1

Anna Text Box

TYPE EMX

CMB-EM-G-U-WH-MTEBP-L1-SD

ISOLITE WWW.ISOLITE.COM

ISOLITE HEADQUARTERS 800.888.5483 31 WATERLOO AVENUE, BERWYN, PA 19312

ISOLITE WEST 800.799.5343 3563 SUELDO SUITE M, SAN LUIS OBISPO, CA 93401

D-7.2.3.0-201 REV-24 20250714

SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT NOTIFICATION.

CONTACT ISOLITE FOR UP TO DATE DETAILS.

LAMP SPACING

DIMENSIONS

CMB

Thermoplastic LED Exit Sign and Emergency Combo

17”

12”

5.125”

8”

8.69”

1.875”

2.94”

4.375”

MOUNTING HEIGHT (FT) CENTER-TO-CENTER SPACING (MULTIPLE UNITS - FT) OPTIMAL AIMING ANGLE FROM GROUND

7 32 20º

8 30 20º

9 29 20º

10 28 20º

11 27 20º

12 26 20º

13 25 20º

14 24 20º

15 23 20º

16 22 20º

17 21 20º

18 19 20º

19 18 20º