This document appears to be a technical drawing related to a state and local contract opportunity for the construction of a new parole and probation building at the Oak Creek Youth Correctional Facility in Albany, Oregon. The drawing provides details on the electrical infrastructure, including the placement of light poles, conduits, and the main electrical distribution panel. The related state and local contract opportunity is seeking bids for all labor, materials, transportation, equipment, and services required for the construction work described in Attachments A and B, as well as other ITB documents. The contract is for the state of Oregon, specifically the jurisdictions of Lake County and the City of Albany.
The document does not provide pricing terms, set asides, incumbents, funding requirements, or other salient commercial details. The emphasis appears to be on the technical specifications and drawings for the electrical infrastructure of the new facility.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2'- 0'' ROUND
BASE COVER
BEHIND HANDHOLE
GROUND LUG LOCATED
NOTE:
SEE FIXTURE SCHEDULE
NON-SHRINK GROUT.
FILL COMPLETELY
UNDER BASE PLATE
2' RADIUS- TYPICAL
PLATE & BASE COVER.
LIGHT POLE WITH BASE
ANCHOR BOLTS AS
PER MANUFACTURERS
RECOMMENDATIONS
CONCRETE BASE
CONDUIT TYPICAL
BRANCH CIRCUIT
M
IN
IM
U
M
AS REQUIRED
MINIMUM
ALL POLES FOR POLE MOUNTED LIGHTING SHALL BE AS INDICATED ON DETAIL THIS
DRAWING. POLE, ANCHOR BOLTS, AND FOUNDATION SHALL BE DESIGNED BY A
REGISTERED STRUCTURAL ENGINEER AND COORDINATED WITH THE LIGHTING FIXTURE
TYPE AND CONFIGURATION BEING PROVIDE, TAKING INTO ACCOUNT MOUNTING HEIGHT,
MAXIMUM PROJECTED AREA, MOUNTING ARM LENGTH, QUANTITY OF FIXTURES AND
100 MPH BASIC, AND 130 MPH GUST WIND VELOCITY. CONTRACTOR SHALL FURNISH
FINAL POLE BASE DESIGN TO ARCHITECT WITH LIGHTING FIXTURE SUBMITTALS. POLE FOUNDATION IS
MINIMUM REQUIREMENT. CONTRACTOR SHALL VERIFY SOIL CONDITIONS
WHICH MAY AFFECT FOUNDATION SIZE.
FINISH GRADE
NTSE7.01
3 POLE BASE
Comment #12 Response:
Comment #4 Response:
Oak Creek Youth Correctional Facility
Comment Responses 7/25/2024
Nicholas Evano, PE, ColeBreit Engineering
EV
EV
EV
SWITCHBOARD
'MDP'
NEW UTILITY TRANSFORMER
'G1'
2P1- 83.
'G1'
2P1- 83.
'G1'
2P1- 83.
'G1'
2P1- 83.
'G1'
2P1- 83.
'G1'
2P1- 83.
'G2'
2P1- 83.
(1)1-1/2"C. (LIGHTING)
(2)1-1/2"C.(EVC)
2P1-27,29.
2P1-31,33.
2P1-23,25.
(1)1"C. (LIGHTING)
(1)1-1/2"C. (LIGHTING)
(1)1-1/2"C. (EVC)
(1)1"C. (LIGHTING)
(1)1-1/2"C. (EVC)
(1)1"C. (LIGHTING)
(2)4"C.
UTILITY METERING SECTION
M
TO EXISTING CPI SWITCH #LTL/4
TO EXISTING VAULT-MOUNTED 150 KVA 3-PH TRANSFORMER
EXISTING BURIED 3-PHASE PRIMARY LINE EXTENSION TO REMAIN
(3)3"C.
(1)1-1/2"C.(EVC)
STUB FOR FUTURE EV, TYP. (2)
(1)1-1/2"C. (EVC)
1/16" = 1'-0"E1.01
1 ELECTRICAL SITE PLAN
1/32" = 1'-0"
SK#1
R3 - 11/18/2024
LOCATION OF EXISTING SITE LIGHT
QUESTION #55
SK#2