A5.27 R1 07-16-2024.pdf

PDF 397 KB Posted

Attached to
Oak Creek Youth Correctional Facility (OCYCF) New Parole and Probation
Solicitation number
S-DASOBO-00009472
Issued by
Lake County, Albany City, Oregon

About this file

This document appears to be an Invitation to Bid (ITB) for the construction of a new parole and probation building at the Oak Creek Youth Correctional Facility (OCYCF) in Albany, Oregon. The purpose of the ITB is to establish a contract for all labor, materials, transportation, equipment, and services required for the construction work described in Attachment A, Attachment B, and the ITB documents. The project is located in Lake County and Albany City, Oregon, and the contract term is unspecified.

The ITB requires bidders to provide pricing for the requested construction work. No additional details are provided regarding set-asides, incumbents, funding requirements and sources, or other salient information.

View the file

Other files

File Type Posted
Specs_Project Manual_Appendix.pdf PDF
G0.01 R1 07-16-2024 and R3 11-18-2024.pdf PDF
Addendum4_S-DASOBO-00009472_OCYCF_ParoleProbation.pdf PDF
A1.61 R2 11-13-2024.pdf PDF
Addendum 2 S-DASOBO-00009472_OCYCF_ParoleProbation.pdf PDF
EP-0097-23 OYA New Building Improvements EPSC Plan-1.pdf PDF
S-DASOBO-00009472_Q&A_07192024.pdf PDF
S1.10 R2_S5.10 R2.pdf PDF
Addendum 3 S-DASOBO-00009472_OCYCF_ParoleProbation.pdf PDF
S0.10 R3 07-31-2024.pdf PDF
C3.00 R2 11-13-2024.pdf PDF
S-DASOBO-00009472_OCYCF Parole_ PreBidAttendance.pdf PDF
IntentToAward_Notice_AllBidders_12052024.pdf PDF
OCYCF Substitution Request 265100_Approved.pdf PDF
Addendum 5 S-DASOBO-00009472_OCYCF_ParoleProbation_08222024.pdf PDF
OCYCF Substitution Request 074113_Approved.pdf PDF
Addendum 008 S-DASOBO-00009472_OCYCF_ParoleProbation.pdf PDF
Addendum1_Attachment1_Geotech Report YWTP.pdf PDF
First Tier Filled Out FCC.pdf PDF
FINAL_OYA Construction Set_2024-0412.pdf PDF
A6.01 R2 11-13-2024.pdf PDF
S2.10 R1_S2.11 R1_S8.11 R1_S8.12 R1.pdf PDF
A6.01 R1 07-16-2024.pdf PDF
Addendum 1 S-DASOBO-00009472_OCYCF_ParoleProbation_Corrected.pdf PDF
Addendum 7 S-DASOBO-00009472_OCYCF_ParoleProbation_10162024.pdf PDF
FINAL_OCYCF_Specifications_2024-0614.pdf PDF
REVISED SPECIFICATIONS 11-13-2024_corrected.pdf PDF
Structural Calculations_Stamped.pdf PDF
Bid_Tab_S-DASOBO-00009472_OCYCF Parole and Probation.pdf PDF
SK2 R3 11-18-2024.pdf PDF
Structural Calculations _Add_MechanicalScreenWall.pdf PDF
S-DASOBO-00009472_OCYCF_Parole_Probation_06242024.pdf PDF
S-DASOBO-00009472_Q&A_11212024_Final.pdf PDF
SK1 R3 11-18-2024.pdf PDF
S-DASOBO-00009472_Q&A_11182024_Final.pdf PDF
G0.03 R1 07-16-2024.pdf PDF
G1.01 R1 07-16-2024.pdf PDF
Addendum 009 S-DASOBO-00009472_OCYCF_ParoleProbation_FinalApproved_11182024.pdf PDF
9473 ITB.pdf PDF
Addendum 6 S-DASOBO-00009472_OCYCF_ParoleProbation.pdf PDF
OCYCF Substitution Request 075400_Approved.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

6'-0"

ROOF DRAIN

OVERFLOW DRAIN

TAPERED EDGE STRIP AT PERIMETER OF

DRAIN SUMP

FOR TYPICAL ROOF DRAIN (INSULATION

BELOW MEMBRANE),

FOR TERRACE ROOF DRAIN (INSULATION

ABOVE MEMBRANE),

ADD STAINLESS STEEL SADDLE

FLASHINGS AT ALL WALL

TERMINATIONS /

TRANSITIONS.

SADDLES SHOULD BE FULLY

SOLDIERED WATERTIGHT

AND HAVE 180 DEGREE

HEMS AT ENDS.

INCORPORATE FLANGE INTO

WRB ON WALL, TYP.

OCCURS AT SQUARE

PENETRATIONS THROUGH

ROOF MEMBRANE.

COLLAR SHOULD BE RIVETED

AND FULLY SOLDIERED

WATERTIGHT.

TOP OF PARAPET

15' - 0"

MECHANICAL EQUIPMENT BY

OTHERS.

MECHANICAL CURB BY OTHERS.

TPO ROOFING MEMBRANE.

M

IN

CANT STRIP.

COVER BOARD.

RIGID INSULATION.

TOP OF PARAPET

15' - 0"

HIGH TEMP SELF-ADHERED MEMBRANE

SHEET METAL FLASHING

SCUPPER AND DOWNSPOUT

TOP OF PARAPET

15' - 0"

TOP PLATE UPPER ROOF

16' - 0"

Z-FURRING.

LOUVERED METAL SCREEN,

FINISH TBD.

STEEL FRAMING, REFER TO STRUCTURAL.

VAPOR BARRIER.

FLUID APPLIED WATERPROOFING.

ROUGH CARPENTRY, REFER

TO STRUCTURAL.

FLASHING SHEET CENTERED ON ROOF

DRAIN.

REINFORCING SHEET.

2" COLLAR AT OVERFLOW DRAIN ONLY.

LEAD FLASHING - SET IN CONTINUOUS

BED OF PLASTIC CEMENT.

DRAIN RECEIVER.

ROOF DRAIN ASSEMBLY.

RIGID INSULATION. REFER TO ROOF-

CEILING TYPES.

TPO ROOFING SYSTEM.

SUBSTRATE BOARD.

PLYWOOD ROOF SHEATHING.

CENTERLINE OF ROOF DRAIN.

(2) LAYERS TAPER STRIP.

1'-6"

3"

3"

PROJECT #

DATE:

REVISIONS

Copyright © 2021-22 STUDIO 3 ARCHITECTURE, INC.

SHEET:

A5.27

11/17/2023

2021-208

O ak

C re ek Y ou th

C or re ct io na l F ac ili ty

PR

O

B

AT

IO

N

/P

AR

O

LE

F

AC

IL

IT

Y

L

O C

H N

E R R

D S

E A

LB

A

N Y O

R

C

O N

S T R U

C T

IO

N S

E T

1" = 1'-0"

1 ROOF DRAIN & OVERFLOW SUMP PLAN DETAIL

3" = 1'-0"

4 SADDLE FLASHING DETAIL

6" = 1'-0"

5 STORM COLLAR DETAIL

1 1/2" = 1'-0"

11 SECTION AT MECHANICAL CURB

1 1/2" = 1'-0"

2 SECTION AT DOWNSPOUT

0" 1'-0" 2'-0"2" 4" 8"

0" 1'-0" 2'-0"2" 4" 8"

0" 1'-0" 2'-0"2" 4" 8"0" 1'-0" 2'-0"2" 4" 8"

0" 1'-0" 2'-0"2" 4" 8"

1 1/2" = 1'-0"

12 SECTION AT MECHANICAL SCREEN

0" 1'-0" 2'-0"2" 4" 8" 6" = 1'-0"

9 ROOF DRAIN DETAIL (INSULATION BELOW MEMBRANE)

0" 1'-0" 2'-0"2" 4" 8"

1 07/16/2024

Sheets
A5.27 - EXTERIOR ROOF DETAILS
A6.01 - SCHEDULES
G0.01 - COVER SHEET
G0.03 - GENERAL NOTES
G1.01 - CODE REVIEW PLANS