S02-RFP Attachment 12-Specifications-Columbia_Part2.pdf

PDF 2 MB Posted

Attached to
Y1DZ--Renovate B3-EHRM Training and Admin Space Project 544 22 703 EHRM Construction 6439 Garner's Ferry Rd. Columbia VAMC Columbia, SC 29209
Solicitation number
36C77626R0032_2
Issued by

About this file

This document is a Limited Asbestos and Lead-Based Paint Assessment Report prepared by S&ME, Inc. for a third-floor renovation project at Building 3 of the Dorn VA Hospital in Columbia, South Carolina. The assessment was conducted on September 28, 2022, to identify asbestos-containing materials (ACMs) and lead-based paint (LBP) in rooms 312, 320, 320A, 330, 351, and a small conference room prior to planned renovation activities.

The asbestos assessment, performed in accordance with SCDHEC Regulation 61-86.1 and EPA NESHAP standards, involved bulk sampling and analysis of suspect ACMs including drywall, joint compound, plaster, duct mastic, and black sealant. Analysis via Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) yielded no asbestos detected (NAD) in concentrations exceeding one percent across all samples. The lead-based paint assessment, using X-Ray Fluorescence (XRF) analysis, identified coatings exceeding the SCDHEC disposal criterion of 0.7 mg/cm² on three surface types: beige metal window frames (1.30 to 13.10 mg/cm²), beige plaster pillars (14.50 to 16.00 mg/cm²), and an orange metal plate beneath a window (3.60 mg/cm²). The report recommends that contractors comply with OSHA regulations 29 CFR 1926.62 regarding lead-containing paint disturbance and disposal in permitted Class Two or Class Three landfills. All sampling, analysis, and laboratory certifications are documented in the appendices, including SCDHEC inspector licenses for Bobby McAllister and Travis Knight.

View the file

Other files

File Type Posted
S06-Amendment 0006-Att 1-SF30-Columbia.pdf PDF
S06 - Amendment 0006-Att 2-Tech Questions-Columbia.pdf PDF
S06 - Amendment 0005-Att 1-Tech Questions-Columbia.pdf PDF
S06-Amendment 0005-Att 2-SF30-Columbia.pdf PDF
S06-Amendment 0004-Att 1- BLDG 3 EHRM - DIV 23 Specs Combined.pdf PDF
S06-Amendment 0004-Att 3-HL100.pdf PDF
S06-Amendment 0004-Att 2 - Lim. AB LBP Report - Bld3 EHRM.pdf PDF
S06-Amendment 0004-Att 5- SF30-Columbia.pdf PDF
S06 -Amendment 0004-Att 4- Tech Questions-Columbia.pdf PDF
S06-36C77626R0032-Amendment 0003.pdf PDF
S06-36C77626R0032 Amendment 0002.pdf PDF
S04- Pre Bid Conference - Columbia.pptx PPTX presentation
S06-36C77626R0032 0001.pdf PDF
S06-Site Visit Sign-In Sheet 03062026-Columbia.pdf PDF
S06-RFP Attachment 17-Spce Update for 01321615-2025-12.pdf PDF
S02-RFP Attachment 15-Specifications-Columbia_Part5.pdf PDF
S02-RFP Attachment 8- Fire Sup Drawings-COL.pdf PDF
S02-RFP Attachment 5- ARCH Drawings-COL.pdf PDF
S02-RFP Attachment 4-Campus Map-Columbia.pdf PDF
S02-36C77626R0032-Columbia.pdf PDF
S02-RFP Attachment 10- Plumbing Drawings-COL.pdf PDF
S02-RFP Attachment 16-Final SOW-Col.pdf PDF
S02-RFP Attachment 14-Specifications-Columbia_Part4.pdf PDF
S02-RFP Attachment 7- Fire Alarm Drawings-COL.pdf PDF
S02-RFP Attachment 2 Site Visit Information-Columbia.pdf PDF
S02-RFP Attachment 13-Specifications-Columbia_Part3.pdf PDF
S02-RFP Attachment 11-Specifications-Columbia_Part1.pdf PDF
S02-RFP Attachment 9- Mechanical Drawings-COL.pdf PDF
S02-RFP Attachment 6- Electrical Drawings-COL.pdf PDF
S02 - RFP Attachment 3 - Limitations on Subcontracting - Columbia.docx DOCX document
S02-RFP Attachment 1-Wage Rates-Col.txt TXT text file
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S&ME, Inc. | 134 Suber Road | Columbia, SC 29210 | p 803.561.9024 | www.smeinc.com

October 17, 2022

Odell International

129 Fast Lane, Suite 200

Mooresville, NC 28177

Attention: Mr. Richard Cantwell, Jr.

rickc@odell-intl.com

Reference: Limited Asbestos & Lead-Based Paint Assessment

VAMC COLSC – Building 3 Third Floor Renovation

Dorn VA Hospital

6439 Garners Ferry Road

Columbia, South Carolina 29209

S&ME Project No. 22610418

Dear Mr. Cantwell;

S&ME, Inc. (S&ME) is pleased to provide the enclosed report detailing our limited asbestos and lead-based paint assessment at the referenced site. The purpose of the assessment was to identify, to the extent feasible, potential asbestos-containing materials (ACMs) and lead-based paint (LBP) associated with the planned third-floor renovation of rooms 312, 320, 320A, 330, 351 and small conference room in Building 3 located at the Dorn VA

Hospital located at 6439 Garners Ferry Road in Columbia, South Carolina. Our services were performed in general accordance with our Agreement for Services, Form Number AS-071 and S&ME Proposal 22610418, dated August

1, 2022.

This report is provided for the use of the client. Use of this report by any other parties will be at such party's sole risk and S&ME, Inc. disclaims liability for any such use or reliance by third parties. The results presented in this report are indicative of conditions only during the time of the assessment and of the specific areas referenced.

We appreciate the opportunity to provide you with our industrial hygiene/environmental services. If you have any questions concerning this report, please call us at (803) 561-9024.

Sincerely, S&ME, Inc.

Bobby McAllister Tom Behnke, P.G., CHMM

Asbestos Building Inspector Environmental Services Manager

(SCDHEC Lic. No. BI-01429)

RichardCantwellJr Text Box Note: Please reference Drawings and Specifications for Lead Base Paint (LBP) abatement.

Limited Asbestos & Lead-Based Paint Assessment

VAMC COLSC – Building 3 Third Floor Renovation

6439 Garners Ferry Road Columbia, South Carolina 29209

S&ME Project No. 22610418

October 17, 2022 i

Contents

Executive Summary

1.0 Introduction

2.0 Asbestos Assessment

2.1 Purpose

2.2 Site Description

2.3 Investigative Procedures and Analysis

2.4 Assessment

2.5 Findings and Results

3.0 Lead-Based Paint Assessment

3.1 Investigative Procedures

3.2 Findings and Results

4.0 Conclusions and Recommendations

5.0 Limitations

List of Tables Table I-I Summary of Asbestos Sampling ................................................................................................ I

Appendices Appendix I – Summary of Asbestos Sampling

Appendix II – Floor Plan & Photographs

Appendix III – XRF Lead-Based Paint Reading Summary Table

Appendix IV – Asbestos Bulk Sample Analysis Sheets and Chain of Custody Record

Appendix V – Copy of SCDHEC Inspectors’ Licenses

RichardCantwellJr

VAMC COLSC-Building 3 Third Floor Renovation

6439 Garners Ferry Road Columbia, South Carolina 29209

S&ME Project No. 22610418

October 17, 2022 1

Executive Summary

S&ME conducted a limited asbestos and lead-based paint assessment of the third floor in Building 3 located at the Dorn VA Hospital at 6439 Garners Ferry Road in Columbia, South Carolina. The assessment was performed on

September 28, 2022. The purpose of the assessment was to identify asbestos-containing materials (ACMs) and lead-based paint coatings associated with planned renovations of rooms 312, 320, 320A, 330, 351 and small conference room in the building.

Asbestos The limited asbestos assessment was performed in general accordance with the South Carolina Department of

Health and Environmental Control (SCDHEC) Regulation 61-86.1, Standards of Performance for Asbestos Projects effective May 27, 2011 and with the National Emission Standards for Hazardous Air Pollutants (NESHAP) and the

Asbestos Hazard Emergency Response Act (AHERA). The purpose of the assessment was to identify the presence and quantity of ACMs associated with the building prior to sprinkler head replacement.

The limited asbestos assessment included the bulk sampling and analysis of suspect ACMs from the subject areas.

The suspect materials identified consist of drywall and associated joint compound, plaster, duct mastic and black sealant.

The Environmental Protection Agency (EPA) and SCDHEC define materials as asbestos-containing if an asbestos content of greater than one percent (>1%) is detected in a representative sample. Asbestos, in concentrations greater than one percent, was not identified as a result of the assessment.

Lead-Based Paint Painted surfaces throughout the interior of the subject areas were considered suspect and analyzed for lead content. The coated surfaces exceeding the SCDHEC disposal criteria of 0.7 milligrams per square centimeter

(mg/cm2) were considered lead-based paint for the purpose of this assessment. Tested surfaces that exceeded the 0.7 mg/cm2 threshold include:

Beige metal window frames (1.30 to 13.10 mg/cm2).

Beige plaster pillars (14.50 to 16.00 mg/cm2).

Orange metal plate beneath window (3.60 mg/cm2).

This summary is for convenience only and should not be relied upon without first reading the full contents of this report, including appended materials.

RichardCantwellJr

6439 Garners Ferry Road Columbia, South Carolina 29209

S&ME Project No. 22610418

October 17, 2022 2

1.0 Introduction

S&ME conducted a limited asbestos and lead-based paint assessment of rooms 312, 320, 320A, 330, 351 and small conference room on the third floor in Building 3 located at the Dorn VA Hospital at 6439 Garners Ferry Road in Columbia, South Carolina. The assessment was performed by Bobby McAllister and Travis Knight on September

28, 2022. Mr. McAllister and Mr. Knight are Asbestos Building Inspectors licensed by the South Carolina

Department of Health and Environmental Control (SCDHEC). An Asbestos-Containing Material (ACM) is defined by State and Federal regulations as a building material containing greater than one percent (>1%) of one of the six asbestos minerals regulated by the Environmental Protection Agency (EPA) and the Occupational Safety and

Health Administration (OSHA).

This limited asbestos and lead-based paint assessment was performed in general accordance with S&ME Proposal

No. 22610418, dated August 1, 2022, and SCDHEC Regulation 61-86.1.

Demolition and renovation activities in public and commercial buildings are regulated by OSHA, EPA and SCDHEC.

The EPA and SCDHEC require asbestos assessments, conducted by licensed individuals, prior to renovation and/or demolition projects. Code 40 of Federal Regulations Part 61, Subpart M, Final Rule, National Emissions Standards for Hazardous Air Pollutants (NESHAP) and SCDHEC Regulation 61-86.1 require asbestos assessments, followed by the proper removal, and disposal of ACM that is affected by renovation or demolition. The identification of ACMs will aid in the prevention of occupational exposures and/or environmental releases of airborne asbestos.

Identification of ACM is also required by OSHA 1926.1101. The EPA, OSHA and SCDHEC define ACM as materials containing greater than one (1) percent asbestos in a representative sample. However, OSHA also regulates materials containing less than or equal to one percent asbestos.

2.0 Asbestos Assessment

2.1 Purpose

The purpose of the limited asbestos assessment was to identify the presence and quantity of asbestos-containing materials associated with the subject areas prior to planned renovation activities on the third floor. The identification of ACMs will aid in the prevention of occupational exposures and/or environmental releases of airborne asbestos. Identification of ACMs also complies with Title 40 Code of the Federal Regulations, part 61, and State Regulation 61-86.1 enforced by the SCDHEC, along with Title 29 Code of Federal Regulations, part 1926 enforced by OSHA.

2.2 Site Description

The subject areas are rooms 312, 320, 320A, 330, 351 and small conference room on the third floor of Building 3 located at the Dorn VA Hospital at 6439 Garners Ferry Road in Columbia, South Carolina. The rooms were unfinished with some drywall walls and remnant plaster in various areas. The subject areas were unoccupied at the time of the assessment.

RichardCantwellJr

6439 Garners Ferry Road Columbia, South Carolina 29209

S&ME Project No. 22610418

October 17, 2022 3

The following sections describe the assessment procedures used, results of the suspect ACMs sampled and analyzed, and conclusions and recommendations regarding the subject areas as related to ACMs.

2.3 Investigative Procedures and Analysis

A visual assessment of the subject areas was performed to determine the homogeneous areas (HAs) of suspect

ACMs. Based on EPA definitions used in the Asbestos Hazard Emergency Response Act (AHERA), 40 CFR 763, an

HA of suspect asbestos-containing building material has the same color and texture and is thought to be installed within the same timeframe. S&ME assessed the interior of the subject area for suspect ACMs, surfacing materials, and miscellaneous materials. Significant destructive investigative techniques and sampling were not performed as part of this assessment. Consequently, the possibility exists that suspect materials were not detected in inaccessible areas such as flooring overlays, pipe chases, locked rooms, or wall voids or in areas deemed unsafe to enter by the asbestos inspectors. If additional suspect materials are discovered during future renovation or demolition activities, bulk samples should be collected and analyzed for asbestos content.

The suspect materials identified in connection with the ceiling systems consist of drywall and associated joint compound, plaster, duct mastic and black sealant.

A sampling strategy was developed to provide representative samples of the suspect asbestos-containing materials in accordance with OSHA, SCDHEC and EPA. Bulk samples were then extracted from suspect ACMs, recorded on a chain of custody record, and submitted to S&ME’s in house polarized light microscopy (PLM) lab in

Charlotte, North Carolina for analysis. Non-friable, organically bound (NOB) samples that tested negative via PLM were also submitted to EMSL Analytical’s asbestos laboratory in Pineville, North Carolina for analysis via transmission electron microscopy (TEM).

Polarized Light Microscopy (PLM)

The suspect materials were analyzed by trained microscopists using PLM techniques coupled with dispersion staining in accordance with EPA Test Method Title 40 Code of Federal Regulations, Chapter I (1-1-87 edition), Part

763, Subpart F-APPENDIX A. This method identifies asbestos mineral fibers based on six optical characteristics:

morphology, birefringence, refractive index, extinction angle, sign of elongation and dispersion staining colors.

The laboratory analysis reports the specific type of asbestos identified (there are six asbestos minerals) and the percentage of asbestos present.

Transmission Electron Microscopy (TEM)

In accordance with SCDHEC Regulation 61-86.1, Transmission Electron Microscopy (TEM) confirmation analysis is required to be performed on one sample of any non-friable organically bound material (NOB) that tests negative via PLM analysis. The TEM analysis was performed using EPA 600 Method in accordance with ASTM E2356.

Both the PLM and the TEM laboratories are accredited by the National Voluntary Laboratory Accreditation

Program (NVLAP), which is administered by the National Institute of Standards and Technology.

2.4 Assessment

Identified ACMs were assessed based on the observed condition (good, damaged or significantly damaged) and potential for disturbance. Identified ACMs were also categorized based on the EPA’s NESHAP regulation categories. A friable ACM is classified as an ACM that can be crumbled to a powder by moderate hand pressure.

RichardCantwellJr

6439 Garners Ferry Road Columbia, South Carolina 29209

S&ME Project No. 22610418

October 17, 2022 4

A non-friable ACM is classified as either Category I or Category II non-friable ACM. Category I and Category II non-friable ACMs are distinguished from each other by their fiber release potential when damaged. Generally, Category I non-friable ACM, which by definition includes intact asbestos-containing roofing materials, gaskets, packing, and resilient floor coverings is less likely to become friable and release fibers in a damaged state.

Category II non-friable ACM include all other non-friable ACMs excluding Category I that have a high probability of being rendered friable during removal activities or demolition. All friable ACM, Category I non-friable ACM that has become friable, Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting or abrading, or Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations are considered to be a Regulated Asbestos-Containing Material (RACM).

2.5 Findings and Results

The limited asbestos assessment conducted on September 28, 2022 included the quantification and random bulk sampling of various suspect asbestos-containing materials associated with the third floor renovations. Of the representative materials sampled and analyzed during this assessment, asbestos in concentrations >1% was not identified.

A summary of suspect ACMs sampled and analyzed is provided in Appendix I. A floor plan and photographs of site conditions are provided in Appendix II. The laboratory reports are provided in Appendix IV.

3.0 Lead-Based Paint Assessment

3.1 Investigative Procedures

The limited lead-based paint assessment was conducted for compliance with the SCDHEC limit of 0.7 milligrams

(mg) of lead per square centimeter (cm2) of painted surface for lead-based paint coated waste. SCDHEC, Health

Division defines lead-based paint as a coating containing lead in quantities ≥0.7 mg/cm2 (SCDHEC, Health Division definition #4-53-1320f). Any coated surfaces meeting or exceeding the SCDHEC limit of 0.7 mg/cm2 were considered lead-based paint for the purpose of this assessment.

OSHA does not recognize a threshold level of lead for definition purposes, only the presence or absence of lead.

The current OSHA regulations recognize an airborne action level of thirty micrograms of lead per cubic meter of air (30 µg/m3) during an eight-hour day and a permissible exposure level of fifty micrograms per cubic meter (50 µg/m3).

Representative painted building components and surfaces in the subject areas were analyzed utilizing a Niton

XLp-300A X-Ray Fluorescence (XRF) spectrum analyzer (serial #95004). The suspect painted finishes were selected based on the color of the topcoat and the underlying paint layers and/or the substrate on which it was applied.

The possibility exists that lead-based paint finishes are present in inaccessible areas not tested such as pipe chases, wall voids, etc.

Attached in Appendix III is a summary of the paint readings analyzed by the XRF spectrum lead analyzer. The

XRF summary provides the sample numbers, sample location, component, substrate, paint color, condition, and results.

RichardCantwellJr

6439 Garners Ferry Road Columbia, South Carolina 29209

S&ME Project No. 22610418

October 17, 2022 5

3.2 Findings and Results

Coated surfaces throughout the subject areas were tested for the presence of lead-based paint. Coated surfaces meeting or exceeding the SCDHEC limit of 0.7 milligrams of lead per square centimeter (0.7 mg/cm2) were considered lead-based paint for the purpose of this assessment. Tested surfaces that exceeded the 0.7 mg/cm2 threshold include:

Beige metal window frames (1.30 to 13.10 mg/cm2).

Beige plaster pillars (14.50 to 16.00 mg/cm2).

Orange metal plate beneath window (3.60 mg/cm2).

4.0 Conclusions and Recommendations

The limited asbestos assessment of rooms 312, 320, 320A, 330, 351 and small conference room located on the third floor of Building 3 located at the Dorn VA Hospital located at 6439 Garners Ferry Road in Columbia, South

Carolina did not identify the presence of asbestos-containing materials.

4.1 Lead-Based Paint Conclusions

The limited lead-based paint assessment of the subject areas in Building 3 identified the presence of lead-based coatings on beige metal window frames, beige plaster pillars and orange metal plate beneath window.

Destructive actions to paint containing detectable levels of lead (e.g. paint preparation, component removal, demolition, sanding, grinding, burning, etc.) may require the contractor to comply with the standards of the OSHA regulations 29 CFR 1926.62 (Lead in Construction), including but not limited to training, initial exposure monitoring, the use of personal protective equipment, and medical surveillance. The determination of OSHA applicability is the responsibility of the contractor and dependent upon the paint condition and the planned treatment of the finishes.

The client is advised that OSHA does not recognize a threshold level of lead for definition purposes, only the presence or absence of lead. Consequently, the OSHA regulations governing worker protection for lead-based paint may apply to work practices including the disturbance of paint systems with detectable levels of lead.

Destructive actions (sanding, burning, demolition, component removal, paint preparation) to the lead-containing paint surfaces will require the contractor comply with the standards of OSHA, including but not limited to initial exposure monitoring, the use of personal protective equipment, and medical surveillance.

SCDHEC Regulation 61-107.19 permits demolition materials painted with lead-based paint (≥ 0.7 mg/cm2) to be disposed in a permitted Class Two (C&D) or Class Three Subtitle D, Municipal Solid Waste (MSW) landfill.

Accumulations of paint waste (chips, dust, or flakes) must be tested by the Toxicity Characteristic Leaching

Procedure (TCLP) to determine if the waste is classified as hazardous, which requires disposal in a Subtitle C

(hazardous waste) landfill. Lead waste, at a minimum, must be disposed in a Class Two or Three landfill.

RichardCantwellJr

6439 Garners Ferry Road Columbia, South Carolina 29209

S&ME Project No. 22610418

October 17, 2022 6

5.0 Limitations

This report is provided for the sole use of the Client. Use of this report by any other parties will be at such party’s sole risk, and S&ME disclaims liability for any such use or reliance by third parties. The results presented in this report are indicative of conditions only during the time of the sampling period and of the specific areas referenced. Under no circumstances is this report to be used as a bidding document, or as a project design or specification for removal of ACM.

S&ME performed the services in accordance with generally accepted practices of reputable environmental consultants undertaking similar studies at the same time and in the same geographical area. S&ME has endeavored to meet this standard of care. No other warranty, expressed or implied, is intended or made with respect to this report or S&ME’s services. Users of this report should consider the scope and limitations related to these services when developing opinions as to risks associated with the site. Additional limitations to our survey are as follows:

Significant destructive sampling was not performed during the asbestos assessment. Additional suspect

ACMs may be present in inaccessible locations such as in wall voids, pipe chases or flooring overlays.

Consequently, if additional suspect materials are discovered during future renovation or demolition activities, bulk samples must be collected and analyzed for asbestos content.

RichardCantwellJr

Appendices

RichardCantwellJr

Appendix I – Summary of Asbestos Sampling

Summary of Asbestos Sampling

Project Name: Building 3 – Third Floor Renovation, Dorn VA Hospital Project Number: 22610418

Location: 6439 Garners Ferry Road Columbia, South Carolina Sampling Date(s): September 28, 2022

NAD = No Asbestos Detected NA = Not Applicable SF = Square feet LF = Linear feet CF = Cubic Feet

1Category: F = Friable I = Category I, Non-Friable II= Category II, Non-Friable

2Type; Misc. = Miscellaneous Surf. = Surfacing TSI = Thermal System Insulation

3Condition: Good, Damaged or Significantly Damaged Accessible during renovation or demolition with Potential for Disturbance; Low or High

4Sample analyzed by TEM

Table I-I Summary of Asbestos Sampling

HOMOGENEOUS AREA SAMPLE DATA

HA

Area

Material

Description Material Location Quantity

1Cat

(F/I/II)

2Type

3Condition /

Potential for

Disturbance

Sample

Number Sample Location

Percent and Type

Asbestos

DW Drywall Various areas throughout rooms 950 SF NA Misc. NA/NA

DW-1 Room 351 NAD

DW-2 Room 312 NAD

DW-3 Room 320 NAD

JC Joint compound

Associated with drywall various areas throughout rooms

950 SF NA Surf. NA/NA

JC-1 Room 351 NAD

JC-2 Room 312 NAD

JC-3 Room 312 NAD

PL Plaster Rooms 312 & 320 50 SF NA Surf. NA/NA

PL-1 Room 312 NAD

PL-2 Room 312 NAD

PL-3 Room 320 NAD

DM Duct mastic Room 251 20 SF NA Misc. NA/NA

DM-1 Room 351 NAD

DM-2 Room 351 NAD

4DM-3 Room 351 NAD

BS Black sealant Exterior walls throughout rooms 1,200 SF NA Misc. NA/NA

BS-1 Room 312 NAD

BS-2 Room 351 NAD

4BS-3 Room 320 NAD

RichardCantwellJr

Abbreviations and Hazard Assessment Key

In accordance with the EPA and SCDHEC, a confirmed ACM is assigned a hazard assessment based on its present condition and potential for disturbance. The hazard assessment is used as a tool for prioritization in remedial actions regarding any identified ACM(s). The following key exhibits the criteria that compose the hazard assessment.

Present Condition

F = Friable G = Good (Very localized limited damage)

NF = Non-friable D = Damaged (Damage of less than 10% distributed and less than 25% localized)

SD = Significantly Damaged (Damage equal to or greater than 10% distributed, 25% localized)

Potential for Future Disturbance

LPD = Low Potential for Disturbance (Contact, Vibration, and Air Erosion all of Low Concern)

PD = Potential for Disturbance (Contact, Vibration, or Air Erosion of Moderate Concern)

SPD = Significant Potential for Disturbance (Contact, Vibration, or Air Erosion of High Concern)

Hazard Assessment

Significantly

Damaged

(SD)

Damaged

(D)

Good

(G)

SPD PD LPD SPD PD LPD

7 6 5 4 3 2 1

RichardCantwellJr

Appendix II – Floor Plan & Photographs

AutoCAD SHX Text

%%O%%UFIELD VERIFY DRAWING

AutoCAD SHX Text

THIRD FLOOR PLAN - 668

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text A4

AutoCAD SHX Text N

AutoCAD SHX Text

OF

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET IN SET:

AutoCAD SHX Text

PROJECT TITLE:

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

BUILDING:

AutoCAD SHX Text

REV.

AutoCAD SHX Text

DRAWING:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

ORIG. BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SEAL:

AutoCAD SHX Text University of South Carolina

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

COLUMBIA, SC 29208

AutoCAD SHX Text

AND CONSTRUCTION

AutoCAD SHX Text

CAMPUS PLANNING

AutoCAD SHX Text

SEAL:

AutoCAD SHX Text

SQFT PLAN - THIRD FLOOR

AutoCAD SHX Text

SCHOOL OF MEDICINE V.A. #3

AutoCAD SHX Text

AutoCAD SHX Text

SF3

AutoCAD SHX Text

09MAY07

AutoCAD SHX Text

RLJ

AutoCAD SHX Text

AutoCAD SHX Text A4

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

ST04

AutoCAD SHX Text

161 SF

AutoCAD SHX Text

EV02

AutoCAD SHX Text

59 SF

AutoCAD SHX Text H301

AutoCAD SHX Text

604 SF

AutoCAD SHX Text

ST01

AutoCAD SHX Text

177 SF

AutoCAD SHX Text H302

AutoCAD SHX Text

641 SF

AutoCAD SHX Text

AutoCAD SHX Text

COMM.

AutoCAD SHX Text

116 SF

AutoCAD SHX Text

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

131 SF

AutoCAD SHX Text

AutoCAD SHX Text

MECH.

AutoCAD SHX Text

156 SF

AutoCAD SHX Text

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

70 SF

AutoCAD SHX Text

AutoCAD SHX Text

COMM.

AutoCAD SHX Text

58 SF

AutoCAD SHX Text

ST03

AutoCAD SHX Text

222 SF

AutoCAD SHX Text

ST02

AutoCAD SHX Text

211 SF

AutoCAD SHX Text

EV01

AutoCAD SHX Text

58 SF

AutoCAD SHX Text 320A

AutoCAD SHX Text

137 SF

AutoCAD SHX Text 341A

AutoCAD SHX Text

150 SF

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

AutoCAD SHX Text

UPDATED PER LATEST WALK THROUGH

AutoCAD SHX Text

19MAY11

AutoCAD SHX Text

AutoCAD SHX Text

146 SF

AutoCAD SHX Text

AutoCAD SHX Text

114 SF

AutoCAD SHX Text

AutoCAD SHX Text

114 SF

AutoCAD SHX Text

AutoCAD SHX Text

112 SF

AutoCAD SHX Text

AutoCAD SHX Text

112 SF

AutoCAD SHX Text

AutoCAD SHX Text

293 SF

AutoCAD SHX Text V301

AutoCAD SHX Text

73 SF

AutoCAD SHX Text 306A

AutoCAD SHX Text

339 SF

AutoCAD SHX Text 306B

AutoCAD SHX Text

148 SF

AutoCAD SHX Text 306C

AutoCAD SHX Text

53 SF

AutoCAD SHX Text 306D

AutoCAD SHX Text

87 SF

AutoCAD SHX Text

AutoCAD SHX Text

114 SF

AutoCAD SHX Text

AutoCAD SHX Text

114 SF

AutoCAD SHX Text

AutoCAD SHX Text

117 SF

AutoCAD SHX Text H303

AutoCAD SHX Text

195 SF

AutoCAD SHX Text 301A

AutoCAD SHX Text

138 SF

AutoCAD SHX Text 301B

AutoCAD SHX Text

118 SF

AutoCAD SHX Text 301C

AutoCAD SHX Text

139 SF

AutoCAD SHX Text

AutoCAD SHX Text

2022 SF

AutoCAD SHX Text

AutoCAD SHX Text

UPDATED PER LATEST WALK THROUGH

AutoCAD SHX Text

03MAY16

AutoCAD SHX Text

AutoCAD SHX Text

UPDATED PER LATEST WALK THROUGH

AutoCAD SHX Text

02JUN17

AutoCAD SHX Text 301D

AutoCAD SHX Text

226 SF

AutoCAD SHX Text

AutoCAD SHX Text

1512 SF

AutoCAD SHX Text 360A

AutoCAD SHX Text

291 SF

AutoCAD SHX Text

AutoCAD SHX Text

978 SF

AutoCAD SHX Text

AutoCAD SHX Text

MECH.

AutoCAD SHX Text

179 SF

AutoCAD SHX Text

AutoCAD SHX Text

102 SF

AutoCAD SHX Text

AutoCAD SHX Text

113 SF

AutoCAD SHX Text

AutoCAD SHX Text

113 SF

AutoCAD SHX Text

AutoCAD SHX Text

465 SF

AutoCAD SHX Text 342A

AutoCAD SHX Text

394 SF

AutoCAD SHX Text

AutoCAD SHX Text

154 SF

AutoCAD SHX Text

AutoCAD SHX Text

397 SF

AutoCAD SHX Text

AutoCAD SHX Text

1352 SF

AutoCAD SHX Text H304

AutoCAD SHX Text

686 SF

AutoCAD SHX Text

AutoCAD SHX Text

78 SF

AutoCAD SHX Text 312A

AutoCAD SHX Text

9 SF

AutoCAD SHX Text

AutoCAD SHX Text

DRAWING UPDATED - PER WALK THROUGH WITH JON CRAIN - USC SOM FACILITIES STAFF

AutoCAD SHX Text

21MAY18

AutoCAD SHX Text

AutoCAD SHX Text

DRAWING UPDATED PER 2020 RENOVATION AS COORDINATED WITH USC SOM FACILITIES STAFF

AutoCAD SHX Text

20FEB20

AutoCAD SHX Text

FIXT_CODE

AutoCAD SHX Text

FU_TOTAL

AutoCAD SHX Text

FU_WASTE

AutoCAD SHX Text

FU_HOT

AutoCAD SHX Text

FU_COLD

AutoCAD SHX Text

AutoCAD SHX Text

306 SF

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

149 SF

AutoCAD SHX Text

AutoCAD SHX Text

MEN

AutoCAD SHX Text

111 SF

AutoCAD SHX Text

AutoCAD SHX Text

99 SF

vhacmscrosbS Polygon vhacmscrosbS Rectangle vhacmscrosbS Callout Visitor Center vhacmscrosbS Callout CERNER Solutions Architects vhacmscrosbS Rectangle vhacmscrosbS Rectangle vhacmscrosbS Callout CERNER Admin Support/Command Center vhacmscrosbS Callout Briefing Center vhacmscrosbS Rectangle vhacmscrosbS Callout

OIT SPACE

vhacmscrosbS Rectangle vhacmscrosbS Callout Small Conference Area/Ad Hoc Work Area vhacmscrosbS Rectangle vhacmscrosbS Callout Small Conference Area/Ad Hoc Work Area

RichardCantwellJr

Site Photographs VAMC COLSC- Building 3, Dorn VA Hospital

Columbia, South Carolina

S&ME Project 22610418

Taken by: BM & TK Date: September 28, 2022

1 General interior view. 2 Plaster tested negative for asbestos via PLM analysis. Beige plaster pillar tested positive for lead-based paint (14.50 – 16.00 mg/cm2).

3 Black sealant tested negative for asbestos via PLM and TEM analysis. Orange metal plate beneath window tested positive for lead-based paint (3.60 mg/cm2).

4 Duct mastic tested negative for asbestos via PLM and TEM analysis.

RichardCantwellJr

Site Photographs VAMC COLSC- Building 3, Dorn VA Hospital

Columbia, South Carolina

S&ME Project 22610418

Taken by: BM & TK Date: September 28, 2022

5 Drywall and associated joint compound tested negative for asbestos via PLM analysis. 6 Beige metal window frames tested positive for lead-based paint

(1.30 – 13.10 mg/cm2).

RichardCantwellJr

Appendix III – XRF Lead-Based Paint Reading Summary Table

Serial #95004

PAINT

Site: Building 3 - Dorn VA Hospital Date: September 28, 2022 Ranges (NEG<INC<POS): Device PCS

Reading

Number Floor/Area Room Feature Substrate Condition Color Result

XRF

Reading

(mg/cm²)

1 Shutter

2 Pre-Calibration 1.10

Pre-Calibration 1.00

Pre-Calibration 0.90

5 Interior Room 351 Window frame Metal Non-intact Beige Positive 4.00

6 Interior Room 351 Window Wood Intact White Negative <LOD

7 Interior Room 312 Window frame Metal Non-intact Beige Positive 13.10

8 Interior Room 312 Window Wood Intact White Negative <LOD

9 Interior Room 312 Pillar Plaster Non-intact Beige Positive 16.00

10 Interior Room 320 Window frame Metal Non-intact Beige Negative <LOD

11 Interior Room 320 Window frame Metal Non-intact Beige Positive 1.30

12 Interior Room 320 Window Wood Intact White Negative <LOD

13 Interior Room 320 Pillar Plaster Non-intact Beige Positive 14.50

14 Interior Room 320 Metal plate beneath window Metal Non-intact Orange Positive 3.60

15 Post-Calibration 1.10

16 Post-Calibration 1.10

17 Post-Calibration 0.90

Project No.: 22610418

XRF LEAD-BASED PAINT READING SUMMARY TABLE

RichardCantwellJr

Appendix IV – Asbestos Bulk Sample Analysis Sheets and Chain of

Custody Record

RichardCantwellJr

Columbia Office 134 Suber Rd.

Columbia SC 29210

Asbestos Analysis Summary

Client Job

Client Name

Date Analyzed

Date Received

10/3/2022

9/29/2022

Dorn VA Bldg 3 3rd Fl

9751 Southern Pine Boulevard

Charlotte, NC 28273

704-940-1830 Fax 704-565-4929

NVLAP Lab Code 102075-0

POLARIZED LIGHT MICROSCOPY

Performed by EPA 600/R-93/116 Method

Non-Asbestos Fibrous Non-Fibrous

Lab ID: Sample #: Appearance %/Type

Job Number 22610418

Asbestos Comments %/Type %/Type

3 CELLULOSE

2 GLASS

95 GYPSUM22-10927 DW-1 TAN/BEIGE FIBROUS ND

98 CELLULOSE

<1 GLASS

2 GYPSUM22-10928 DW-2 TAN/BEIGE FIBROUS ND

2 GLASS

<1 CELLULOSE

98 GYPSUM22-10929 DW-3 TAN/BEIGE FIBROUS ND

100 OTHER22-10930 JC-1 WHITE NONFIBROUS ND

For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not

Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.

The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion

Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response

Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None

Detected" for these materials is recommended.

Analyzed by: Jane Wasilewski Jane Wasilewski Laboratory Manager

Additional Comments: Issued 10/03/22

Non-Asbestos Fibrous Non-Fibrous

Lab ID: Sample #: Appearance %/Type

Job Number 22610418

Asbestos Comments %/Type %/Type

100 OTHER22-10931 JC-2 WHITE NONFIBROUS ND

100 OTHER22-10932 JC-3 WHITE NONFIBROUS ND

100 OTHER22-10933A PL-1 TAN NONFIBROUS NDMASTIC

100 OTHER22-10933B PL-1 WHITE NONFIBROUS NDSKIM COAT

100 OTHER22-10933C PL-1 GREY GRANULAR NDPLASTER

100 OTHER22-10934A PL-2 TAN NONFIBROUS NDMASTIC

For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not

Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.

The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion

Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response

Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None

Detected" for these materials is recommended.

Analyzed by: Jane Wasilewski Jane Wasilewski

Job Number 22610418

Asbestos Comments %/Type %/Type

100 OTHER22-10934B PL-2 WHITE NONFIBROUS NDSKIM COAT

100 OTHER22-10934C PL-2 GREY GRANULAR NDPLASTER

100 OTHER22-10935A PL-3 TAN NONFIBROUS NDMASTIC

100 OTHER22-10935B PL-3 WHITE NONFIBROUS NDSKIM COAT

100 OTHER22-10935C PL-3 GREY GRANULAR NDPLASTER

100 OTHER22-10936 DM-1 BEIGE PLIABLE ND

For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not

Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.

The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion

Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response

Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None

Detected" for these materials is recommended.

Analyzed by: Jane Wasilewski Jane Wasilewski

Job Number 22610418

Asbestos Comments %/Type %/Type

100 OTHER22-10937 DM-2 BEIGE PLIABLE ND

2 GLASS 98 OTHER22-10939 BS-1 BLACK NONFIBROUS ND

100 OTHER22-10940 BS-2 BLACK NONFIBROUS ND

For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not

Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.

The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion

Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response

Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None

Detected" for these materials is recommended.

Analyzed by: Jane Wasilewski Jane Wasilewski

EMSL Analytical, Inc.

10801 Southern Loop Blvd Pineville, NC 28134

Tel/Fax: (704) 525-2205 / (704) 525-2382 http://www.EMSL.com / charlottelab@emsl.com

EMSL Order: 412210009

Customer ID: SMEI54

Customer PO: 22610418

Project ID:

Attention: Jane Wasilewski Phone: (704) 940-1830

S&ME, Inc. Fax: (704) 565-4929

9771D Southern Pine Blvd. Received Date: 10/03/2022 1:35 PM

Charlotte, NC 28273 Analysis Date: 10/05/2022

Collected Date:

22610418Project:

Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via

EPA/600/R-93/116 Section 2.5.5.1

Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types

DM-3

412210009-0001

Mastic Only White

Non-Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

BS-3

412210009-0002

Sealant Black

Non-Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

Analyst(s)

Derrick Young (2) Lee Plumley, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. EMSL recommends that samples reported as none detected or <1% undergo additional analysis via PLM to avoid the possibility of false negatives.

Samples analyzed by EMSL Analytical, Inc. Pineville, NC

Initial report from: 10/06/2022 07:50:59

ASB_PLMEPANOB_0012_0002 Printed 10/6/2022 7:51:05AM Page 1 of 1

RichardCantwellJr

OrderID: 412210009

RichardCantwellJr

Appendix V – Copy of SCDHEC Inspectors’ Licenses

S&ME, Inc. | 134 Suber Road | Columbia, SC 29210 | p 803.561.9024 | www.smeinc.com

South Carolina Department of

Health and Environmental Control

Asbestos License

Travis Knight

RichardCantwellJr

VAMC Columbia Bldg. 3 VA Project 544-22-703

Renovate B3 for EHRM Admin & Training 07-15-2025

100% Bid Documents

05 50 00- 1

SECTION 05 50 00

METAL FABRICATIONS

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies items and assemblies fabricated from structural steel shapes and other materials as shown and specified.

B. Items specified.

1. Ladders

1.3 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT

DATA, AND SAMPLES.

C. Shop Drawings:

1. Each item specified, showing complete detail, location in the project, material and size of components, method of joining various components and assemblies, finish, and location, size and type of anchors.

2. Mark items requiring field assembly for erection identification and furnish erection drawings and instructions.

3. Provide templates and rough-in measurements as required.

D. Manufacturer's Certificates:

1. Live load designs as specified.

E. Design Calculations for specified live loads including dead loads.

1.5 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only.

B. American Society of Mechanical Engineers (ASME):

B18.6.1-97..............Wood Screws

B18.2.2-87(R2010).......Square and Hex Nuts

C. American Society for Testing and Materials (ASTM):

A36/A36M-14.............Structural Steel

A47-99(R2014)...........Malleable Iron Castings

A48-03(R2012)...........Gray Iron Castings

A53-12..................Pipe, Steel, Black and Hot-Dipped, Zinc-Coated

Welded and Seamless

A123-15.................Zinc (Hot-Dip Galvanized) Coatings on Iron and

Steel Products

05 50 00- 2

A307-14.................Carbon Steel Bolts and Studs, 60,000 PSI

Tensile Strength

A391/A391M-07(R2015)....Grade 80 Alloy Steel Chain

A786/A786M-15...........Rolled Steel Floor Plate

C1107-13................Packaged Dry, Hydraulic-Cement Grout

(Nonshrink)

D3656-13................Insect Screening and Louver Cloth Woven from

Vinyl-Coated Glass Yarns

F436-16.................Hardened Steel Washers

F468-06(R2015)..........Nonferrous Bolts, Hex Cap Screws, Socket Head

Cap Screws and Studs for General Use

F1667-15................Driven Fasteners: Nails, Spikes and Staples

D. American Welding Society (AWS):

D1.1-15.................Structural Welding Code Steel

D1.3-18.................Structural Welding Code Sheet Steel

E. National Association of Architectural Metal Manufacturers (NAAMM)

AMP 521-01(R2012).......Pipe Railing Manual

AMP 500-06..............Metal Finishes Manual

F. Structural Steel Painting Council (SSPC)/Society of Protective

Coatings:

SP 1-15.................No. 1, Solvent Cleaning

SP 2-04.................No. 2, Hand Tool Cleaning

SP 3-04.................No. 3, Power Tool Cleaning

G. Federal Specifications (Fed. Spec):

RR-T-650E...............Treads, Metallic and Nonmetallic, Nonskid

PART 2 - PRODUCTS

2.1 DESIGN CRITERIA

A. In addition to the dead loads, design fabrications to support the following live loads unless otherwise specified.

B. Ladders and Rungs: 120 kg (250 pounds) at any point.

C. Railings and Handrails: 900 N (200 pounds) in any direction at any point.

2.2 MATERIALS

A. Structural Steel: ASTM A36.

H. Primer Paint: As specified in Section 09 91 00, PAINTING.

2.3 HARDWARE

A. Rough Hardware:

05 50 00- 3

1. Furnish rough hardware with a standard plating, applied after punching, forming and assembly of parts; galvanized, cadmium plated, or zinc-coated by electro-galvanizing process. Galvanized G-90 where specified.

2. Use G90 galvanized coating on ferrous metal for exterior work.

B. Fasteners:

1. Bolts with Nuts:

a. ASME B18.2.2.

b. ASTM A307 for 415 MPa (60,000 psi) tensile strength bolts.

c. ASTM F468 for nonferrous bolts.

2. Screws: ASME B18.6.1.

3. Washers: ASTM F436, type to suit material and anchorage.

2.4 FABRICATION GENERAL

A. Material

1. Use material as specified. Use material of commercial quality and suitable for intended purpose for material that is not named or its standard of quality not specified.

2. Use material free of defects which could affect the appearance or service ability of the finished product.

B. Size:

1. Size and thickness of members as shown.

2. When size and thickness is not specified or shown for an individual part, use size and thickness not less than that used for the same component on similar standard commercial items or in accordance with established shop methods.

C. Connections

1. Except as otherwise specified, connections may be made by welding, or bolting.

3. Design size, number and placement of fasteners, to develop a joint strength of not less than the design value.

4. Holes, for bolts: Accurately punched or drilled and burrs removed.

5. Size and shape welds to develop the full design strength of the parts connected by welds and to transmit imposed stresses without permanent deformation or failure when subject to service loadings.

6. Use bolts of material selected to prevent corrosion (electrolysis) at bimetallic contacts. Plated or coated material will not be approved.

05 50 00- 4

D. Fasteners and Anchors

1. Use methods for fastening or anchoring metal fabrications to building construction as shown or specified.

2. Where fasteners and anchors are not shown, design the type, size, location and spacing to resist the loads imposed without deformation of the members or causing failure of the anchor or fastener, and suit the sequence of installation.

3. Use material and finish of the fasteners compatible with the kinds of materials which are fastened together and their location in the finished work.

5. Fasteners for securing metal fabrication to existing construction or new construction may be expansion bolts, toggle bolts, power actuated drive pins, welding, self drilling and tapping screws or bolts.

E. Workmanship

1. General:

a. Fabricate items to design shown.

b. Furnish members in longest lengths commercially available within the limits shown and specified.

c. Fabricate straight, true, free from warp and twist, and where applicable square and in same plane.

d. Provide holes, sinkages and reinforcement shown and required for fasteners and anchorage items.

e. Provide openings, cut-outs, and tapped holes for attachment and clearances required for work of other trades.

f. Prepare members for the installation and fitting of hardware.

h. Fabricate surfaces and edges free from sharp edges, burrs and projections which may cause injury.

2. Welding:

a. Weld in accordance with AWS.

b. Welds shall show good fusion, be free from cracks and porosity and accomplish secure and rigid joints in proper alignment.

c. Where exposed in the finished work, continuous weld for the full length of the members joined and have depressed areas filled and protruding welds finished smooth and flush with adjacent surfaces.

d. Finish welded joints to match finish of adjacent surface.

05 50 00- 5

3. Joining:

a. Miter or butt members at corners.

b. Where frames members are butted at corners, cut leg of frame member perpendicular to surface, as required for clearance.

5. Cutting and Fitting:

a. Accurately cut, machine and fit joints, corners, copes, and miters.

b. Fit removable members to be easily removed.

c. Design and construct field connections in the most practical place for appearance and ease of installation.

d. Fit pieces together as required.

e. Fabricate connections for ease of assembly and disassembly without use of special tools.

f. Joints firm when assembled.

g. Conceal joining, fitting and welding on exposed work as far as practical.

i. The fit of components and the alignment of holes shall eliminate the need to modify component or to use exceptional force in the assembly of item and eliminate the need to use other than common tools.

F. Finish:

1. Finish exposed surfaces in accordance with NAAMM AMP 500 Metal

Finishes Manual.

3. Steel and Iron: NAAMM AMP 504.

a. Zinc coated (Galvanized): ASTM A123, G90 unless noted otherwise.

b. Surfaces exposed in the finished work:

1) Finish smooth rough surfaces and remove projections.

2) Fill holes, dents and similar voids and depressions with epoxy type patching compound.

c. Shop Prime Painting:

1) Surfaces of Ferrous metal:

a) Items not specified to have other coatings.

b) Galvanized surfaces specified to have prime paint.

c) Remove all loose mill scale, rust, and paint, by hand or power tool cleaning as defined in SSPC-SP2 and SP3.

05 50 00- 6

d) Clean of oil, grease, soil and other detrimental matter by use of solvents or cleaning compounds as defined in SSPC-

SP1.

e) After cleaning and finishing apply one coat of primer as specified in Section 09 91 00, PAINTING.

G. Protection:

2. Spot prime all abraded and damaged areas of zinc coating which expose the bare metal, using zinc rich paint on hot-dip zinc coat items and zinc dust primer on all other zinc coated items.

2.5 SUPPORTS

A. General:

1. Fabricate ASTM A36 structural steel shapes as shown.

2. Use clip angles or make provisions for welding hangers and braces to overhead construction.

3. Field connections may be welded or bolted.

2.14 LADDERS

A. Steel Ladders:

1. Fixed-rail type with steel rungs shouldered and headed into and welded to rails.

2. Fabricate angle brackets of 50 mm (2 inch) wide by 13 mm (1/2 inch) thick steel; brackets spaced maximum of 1200 mm (4 feet) apart and of length to hold ladder 175 mm (7 inches) from wall to center of rungs. Provide turned ends or clips for anchoring.

3. Provide holes for anchoring with expansion bolts through turned ends and brackets.

4. Where shown, fabricate side rails curved, twisted and formed into a gooseneck.

5. Galvanize exterior ladders after fabrication, ASTM A123, G-90.

C. Ladder Rungs:

1. Fabricate from steel bars of diameter shown.

3. Galvanized after fabrication, ASTM A123, G-90 rungs for exterior use and for access to pits.

PART 3 - EXECUTION

3.1 INSTALLATION, GENERAL

A. Set work accurately, in alignment and where shown, plumb, level, free of rack and twist, and set parallel or perpendicular as required to line and plane of surface.

05 50 00- 7

D. Field weld in accordance with AWS.

1. Design and finish as specified for shop welding.

2. Use continuous weld unless specified otherwise.

E. Install anchoring devices and fasteners as shown and as necessary for securing metal fabrications to building construction as specified.

F. Spot prime all abraded and damaged areas of zinc coating as specified and all abraded and damaged areas of shop prime coat with same kind of paint used for shop priming.

3.2 INSTALLATION OF SUPPORTS

A. Anchorage to structure.

1. Secure angles or channels and clips to overhead structural steel by continuous welding unless bolting is shown.

2. Secure supports to concrete inserts by bolting or continuous welding as shown.

3. Secure supports to mid height of concrete beams when inserts do not exist with expansion bolts and to slabs, with expansion bolts.

unless shown otherwise.

4. Secure steel plate or hat channels to studs as detailed.

3.13 LADDERS

A. Anchor ladders to walls and floors with expansion bolts through turned lugs or angle clips or brackets.

3.20 CLEAN AND ADJUSTING

A. Adjust movable parts including hardware to operate as designed without binding or deformation of the members centered in the opening or frame and, where applicable, contact surfaces fit tight and even without forcing or warping the components.

B. Clean after installation exposed prefinished and plated items as recommended by the metal manufacture and protected from damage until completion of the project.

- - - E N D - - -

07 21 13 - 1

1.1 SUMMARY

A. Section Includes:

1. Thermal insulation.

SECTION 07 21 13

THERMAL INSULATION

a. Batt or blanket insulation at exterior framed and furred walls.

2. Acoustical insulation.

a. Batt and blanket insulation at interior framed partitions .

1.2 APPLICABLE PUBLICATIONS

A. Comply with references to extent specified in this section.

B. ASTM International (ASTM):

C516-19 ................Vermiculite Loose Fill Thermal Insulation.

C549-18 ................Perlite Loose Fill Insulation.

C552-17e1 .............Cellular Glass Thermal Insulation.

C553-13(2019) ..........Mineral Fiber Blanket Thermal Insulation for

Commercial and Industrial Applications.

C578-19 ................Rigid, Cellular Polystyrene Thermal Insulation.

C591-20 ................Unfaced Preformed Rigid Cellular

Polyisocyanurate Thermal Insulation.

C612-14(2019) ..........Mineral Fiber Block and Board Thermal

Insulation.

C665-17 ................Mineral-Fiber Blanket Thermal Insulation for

Light Frame Construction and Manufactured

Housing.

C728-17a ...............Perlite Thermal Insulation Board.

C954-18 ................Steel Drill Screws for the Application of

Gypsum Panel Products or Metal Plaster Base to

Steel Studs From 0.033 (0.84 mm) inch to 0.112 inch (2.84 mm) in thickness.

C1002-18 ...............Steel Self-Piercing Tapping Screws for

Application of…

This is the start of the file's text. The full file is on GovTribe.