S06-Amendment 0004-Att 2 - Lim. AB LBP Report - Bld3 EHRM.pdf
PDF 1 MB Posted
- Solicitation number
- 36C77626R0032_2
About this file
This is a Limited Asbestos and Lead-Based Paint Assessment report prepared for Odell International, LLC by S&ME, Inc. for the Dorn VA Hospital Building 3 Third Floor Renovations project located at 6439 Garners Ferry Road, Columbia, South Carolina (Project No. 22610418). The assessment was conducted on September 28, 2022, by licensed asbestos building inspectors Bobby McAllister and Travis Knight.
The asbestos assessment of rooms 312, 320, 320A, 330, 351, and a small conference room identified no asbestos-containing materials (ACMs) in concentrations greater than one percent (>1%). Suspect materials sampled and analyzed included drywall, joint compound, plaster, duct mastic, and black sealant. All bulk samples were analyzed using Polarized Light Microscopy (PLM) in accordance with EPA Test Method 600/R-93/116, with select non-friable organically bound (NOB) samples also analyzed via Transmission Electron Microscopy (TEM) per SCDHEC Regulation 61-86.1 requirements. The lead-based paint assessment using X-Ray Fluorescence (XRF) analysis identified lead-based paint coatings exceeding the SCDHEC disposal criteria of 0.7 mg/cm² on beige metal window frames (1.30 to 13.10 mg/cm²), beige plaster pillars (14.50 to 16.00 mg/cm²), and an orange metal plate beneath a window (3.60 mg/cm²). The report notes that contractors performing destructive work on lead-containing surfaces must comply with OSHA regulations 29 CFR 1926.62, including training, exposure monitoring, personal protective equipment use, and medical surveillance.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Limited Asbestos & Lead-Based Paint
Assessment
Building 3 – Third Floor Renovations
Dorn VA Hospital
6439 Garners Ferry Road
Columbia, South Carolina
S&ME Project No. 22610418
PREPARED FOR:
Odell International, LLC
129 Fast Lane, Suite 200
Mooresville, North Carolina 28117
PREPARED BY:
S&ME, Inc.
134 Suber Road
Columbia, SC 29210
(803) 561-9024
October 17, 2022
INSPECTION PERFORMED BY:
Bobby McAllister & Travis Knight
SCDHEC Lic. BI-01429 & BI-00885
Inspection Date: September 28, 2022
S&ME, Inc. | 134 Suber Road | Columbia, SC 29210 | p 803.561.9024 | www.smeinc.com
October 17, 2022
Odell International
129 Fast Lane, Suite 200
Mooresville, NC 28177
Attention: Mr. Richard Cantwell, Jr.
rickc@odell-intl.com
Reference: Limited Asbestos & Lead-Based Paint Assessment
VAMC COLSC – Building 3 Third Floor Renovation
Dorn VA Hospital
6439 Garners Ferry Road
Columbia, South Carolina 29209
S&ME Project No. 22610418
Dear Mr. Cantwell;
S&ME, Inc. (S&ME) is pleased to provide the enclosed report detailing our limited asbestos and lead-based paint assessment at the referenced site. The purpose of the assessment was to identify, to the extent feasible, potential asbestos-containing materials (ACMs) and lead-based paint (LBP) associated with the planned third-floor renovation of rooms 312, 320, 320A, 330, 351 and small conference room in Building 3 located at the Dorn VA
Hospital located at 6439 Garners Ferry Road in Columbia, South Carolina. Our services were performed in general accordance with our Agreement for Services, Form Number AS-071 and S&ME Proposal 22610418, dated August
1, 2022.
This report is provided for the use of the client. Use of this report by any other parties will be at such party's sole risk and S&ME, Inc. disclaims liability for any such use or reliance by third parties. The results presented in this report are indicative of conditions only during the time of the assessment and of the specific areas referenced.
We appreciate the opportunity to provide you with our industrial hygiene/environmental services. If you have any questions concerning this report, please call us at (803) 561-9024.
Sincerely, S&ME, Inc.
Bobby McAllister Tom Behnke, P.G., CHMM
Asbestos Building Inspector Environmental Services Manager
(SCDHEC Lic. No. BI-01429)
Limited Asbestos & Lead-Based Paint Assessment
VAMC COLSC – Building 3 Third Floor Renovation
6439 Garners Ferry Road Columbia, South Carolina 29209
S&ME Project No. 22610418
October 17, 2022 i
Contents
Executive Summary
1.0 Introduction
2.0 Asbestos Assessment
2.1 Purpose
2.2 Site Description
2.3 Investigative Procedures and Analysis
2.4 Assessment
2.5 Findings and Results
3.0 Lead-Based Paint Assessment
3.1 Investigative Procedures
3.2 Findings and Results
4.0 Conclusions and Recommendations
5.0 Limitations
List of Tables Table I-I Summary of Asbestos Sampling ................................................................................................ I
Appendices Appendix I – Summary of Asbestos Sampling
Appendix II – Floor Plan & Photographs
Appendix III – XRF Lead-Based Paint Reading Summary Table
Appendix IV – Asbestos Bulk Sample Analysis Sheets and Chain of Custody Record
Appendix V – Copy of SCDHEC Inspectors’ Licenses
VAMC COLSC-Building 3 Third Floor Renovation
6439 Garners Ferry Road Columbia, South Carolina 29209
S&ME Project No. 22610418
October 17, 2022 1
Executive Summary
S&ME conducted a limited asbestos and lead-based paint assessment of the third floor in Building 3 located at the Dorn VA Hospital at 6439 Garners Ferry Road in Columbia, South Carolina. The assessment was performed on
September 28, 2022. The purpose of the assessment was to identify asbestos-containing materials (ACMs) and lead-based paint coatings associated with planned renovations of rooms 312, 320, 320A, 330, 351 and small conference room in the building.
Asbestos The limited asbestos assessment was performed in general accordance with the South Carolina Department of
Health and Environmental Control (SCDHEC) Regulation 61-86.1, Standards of Performance for Asbestos Projects effective May 27, 2011 and with the National Emission Standards for Hazardous Air Pollutants (NESHAP) and the
Asbestos Hazard Emergency Response Act (AHERA). The purpose of the assessment was to identify the presence and quantity of ACMs associated with the building prior to sprinkler head replacement.
The limited asbestos assessment included the bulk sampling and analysis of suspect ACMs from the subject areas.
The suspect materials identified consist of drywall and associated joint compound, plaster, duct mastic and black sealant.
The Environmental Protection Agency (EPA) and SCDHEC define materials as asbestos-containing if an asbestos content of greater than one percent (>1%) is detected in a representative sample. Asbestos, in concentrations greater than one percent, was not identified as a result of the assessment.
Lead-Based Paint Painted surfaces throughout the interior of the subject areas were considered suspect and analyzed for lead content. The coated surfaces exceeding the SCDHEC disposal criteria of 0.7 milligrams per square centimeter
(mg/cm2) were considered lead-based paint for the purpose of this assessment. Tested surfaces that exceeded the 0.7 mg/cm2 threshold include:
Beige metal window frames (1.30 to 13.10 mg/cm2).
Beige plaster pillars (14.50 to 16.00 mg/cm2).
Orange metal plate beneath window (3.60 mg/cm2).
This summary is for convenience only and should not be relied upon without first reading the full contents of this report, including appended materials.
6439 Garners Ferry Road Columbia, South Carolina 29209
S&ME Project No. 22610418
October 17, 2022 2
1.0 Introduction
S&ME conducted a limited asbestos and lead-based paint assessment of rooms 312, 320, 320A, 330, 351 and small conference room on the third floor in Building 3 located at the Dorn VA Hospital at 6439 Garners Ferry Road in Columbia, South Carolina. The assessment was performed by Bobby McAllister and Travis Knight on September
28, 2022. Mr. McAllister and Mr. Knight are Asbestos Building Inspectors licensed by the South Carolina
Department of Health and Environmental Control (SCDHEC). An Asbestos-Containing Material (ACM) is defined by State and Federal regulations as a building material containing greater than one percent (>1%) of one of the six asbestos minerals regulated by the Environmental Protection Agency (EPA) and the Occupational Safety and
Health Administration (OSHA).
This limited asbestos and lead-based paint assessment was performed in general accordance with S&ME Proposal
No. 22610418, dated August 1, 2022, and SCDHEC Regulation 61-86.1.
Demolition and renovation activities in public and commercial buildings are regulated by OSHA, EPA and SCDHEC.
The EPA and SCDHEC require asbestos assessments, conducted by licensed individuals, prior to renovation and/or demolition projects. Code 40 of Federal Regulations Part 61, Subpart M, Final Rule, National Emissions Standards for Hazardous Air Pollutants (NESHAP) and SCDHEC Regulation 61-86.1 require asbestos assessments, followed by the proper removal, and disposal of ACM that is affected by renovation or demolition. The identification of ACMs will aid in the prevention of occupational exposures and/or environmental releases of airborne asbestos.
Identification of ACM is also required by OSHA 1926.1101. The EPA, OSHA and SCDHEC define ACM as materials containing greater than one (1) percent asbestos in a representative sample. However, OSHA also regulates materials containing less than or equal to one percent asbestos.
2.0 Asbestos Assessment
2.1 Purpose
The purpose of the limited asbestos assessment was to identify the presence and quantity of asbestos-containing materials associated with the subject areas prior to planned renovation activities on the third floor. The identification of ACMs will aid in the prevention of occupational exposures and/or environmental releases of airborne asbestos. Identification of ACMs also complies with Title 40 Code of the Federal Regulations, part 61, and State Regulation 61-86.1 enforced by the SCDHEC, along with Title 29 Code of Federal Regulations, part 1926 enforced by OSHA.
2.2 Site Description
The subject areas are rooms 312, 320, 320A, 330, 351 and small conference room on the third floor of Building 3 located at the Dorn VA Hospital at 6439 Garners Ferry Road in Columbia, South Carolina. The rooms were unfinished with some drywall walls and remnant plaster in various areas. The subject areas were unoccupied at the time of the assessment.
6439 Garners Ferry Road Columbia, South Carolina 29209
S&ME Project No. 22610418
October 17, 2022 3
The following sections describe the assessment procedures used, results of the suspect ACMs sampled and analyzed, and conclusions and recommendations regarding the subject areas as related to ACMs.
2.3 Investigative Procedures and Analysis
A visual assessment of the subject areas was performed to determine the homogeneous areas (HAs) of suspect
ACMs. Based on EPA definitions used in the Asbestos Hazard Emergency Response Act (AHERA), 40 CFR 763, an
HA of suspect asbestos-containing building material has the same color and texture and is thought to be installed within the same timeframe. S&ME assessed the interior of the subject area for suspect ACMs, surfacing materials, and miscellaneous materials. Significant destructive investigative techniques and sampling were not performed as part of this assessment. Consequently, the possibility exists that suspect materials were not detected in inaccessible areas such as flooring overlays, pipe chases, locked rooms, or wall voids or in areas deemed unsafe to enter by the asbestos inspectors. If additional suspect materials are discovered during future renovation or demolition activities, bulk samples should be collected and analyzed for asbestos content.
The suspect materials identified in connection with the ceiling systems consist of drywall and associated joint compound, plaster, duct mastic and black sealant.
A sampling strategy was developed to provide representative samples of the suspect asbestos-containing materials in accordance with OSHA, SCDHEC and EPA. Bulk samples were then extracted from suspect ACMs, recorded on a chain of custody record, and submitted to S&ME’s in house polarized light microscopy (PLM) lab in
Charlotte, North Carolina for analysis. Non-friable, organically bound (NOB) samples that tested negative via PLM were also submitted to EMSL Analytical’s asbestos laboratory in Pineville, North Carolina for analysis via transmission electron microscopy (TEM).
Polarized Light Microscopy (PLM)
The suspect materials were analyzed by trained microscopists using PLM techniques coupled with dispersion staining in accordance with EPA Test Method Title 40 Code of Federal Regulations, Chapter I (1-1-87 edition), Part
763, Subpart F-APPENDIX A. This method identifies asbestos mineral fibers based on six optical characteristics:
morphology, birefringence, refractive index, extinction angle, sign of elongation and dispersion staining colors.
The laboratory analysis reports the specific type of asbestos identified (there are six asbestos minerals) and the percentage of asbestos present.
Transmission Electron Microscopy (TEM)
In accordance with SCDHEC Regulation 61-86.1, Transmission Electron Microscopy (TEM) confirmation analysis is required to be performed on one sample of any non-friable organically bound material (NOB) that tests negative via PLM analysis. The TEM analysis was performed using EPA 600 Method in accordance with ASTM E2356.
Both the PLM and the TEM laboratories are accredited by the National Voluntary Laboratory Accreditation
Program (NVLAP), which is administered by the National Institute of Standards and Technology.
2.4 Assessment
Identified ACMs were assessed based on the observed condition (good, damaged or significantly damaged) and potential for disturbance. Identified ACMs were also categorized based on the EPA’s NESHAP regulation categories. A friable ACM is classified as an ACM that can be crumbled to a powder by moderate hand pressure.
6439 Garners Ferry Road Columbia, South Carolina 29209
S&ME Project No. 22610418
October 17, 2022 4
A non-friable ACM is classified as either Category I or Category II non-friable ACM. Category I and Category II non-friable ACMs are distinguished from each other by their fiber release potential when damaged. Generally, Category I non-friable ACM, which by definition includes intact asbestos-containing roofing materials, gaskets, packing, and resilient floor coverings is less likely to become friable and release fibers in a damaged state.
Category II non-friable ACM include all other non-friable ACMs excluding Category I that have a high probability of being rendered friable during removal activities or demolition. All friable ACM, Category I non-friable ACM that has become friable, Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting or abrading, or Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations are considered to be a Regulated Asbestos-Containing Material (RACM).
2.5 Findings and Results
The limited asbestos assessment conducted on September 28, 2022 included the quantification and random bulk sampling of various suspect asbestos-containing materials associated with the third floor renovations. Of the representative materials sampled and analyzed during this assessment, asbestos in concentrations >1% was not identified.
A summary of suspect ACMs sampled and analyzed is provided in Appendix I. A floor plan and photographs of site conditions are provided in Appendix II. The laboratory reports are provided in Appendix IV.
3.0 Lead-Based Paint Assessment
3.1 Investigative Procedures
The limited lead-based paint assessment was conducted for compliance with the SCDHEC limit of 0.7 milligrams
(mg) of lead per square centimeter (cm2) of painted surface for lead-based paint coated waste. SCDHEC, Health
Division defines lead-based paint as a coating containing lead in quantities ≥0.7 mg/cm2 (SCDHEC, Health Division definition #4-53-1320f). Any coated surfaces meeting or exceeding the SCDHEC limit of 0.7 mg/cm2 were considered lead-based paint for the purpose of this assessment.
OSHA does not recognize a threshold level of lead for definition purposes, only the presence or absence of lead.
The current OSHA regulations recognize an airborne action level of thirty micrograms of lead per cubic meter of air (30 µg/m3) during an eight-hour day and a permissible exposure level of fifty micrograms per cubic meter (50 µg/m3).
Representative painted building components and surfaces in the subject areas were analyzed utilizing a Niton
XLp-300A X-Ray Fluorescence (XRF) spectrum analyzer (serial #95004). The suspect painted finishes were selected based on the color of the topcoat and the underlying paint layers and/or the substrate on which it was applied.
The possibility exists that lead-based paint finishes are present in inaccessible areas not tested such as pipe chases, wall voids, etc.
Attached in Appendix III is a summary of the paint readings analyzed by the XRF spectrum lead analyzer. The
XRF summary provides the sample numbers, sample location, component, substrate, paint color, condition, and results.
6439 Garners Ferry Road Columbia, South Carolina 29209
S&ME Project No. 22610418
October 17, 2022 5
3.2 Findings and Results
Coated surfaces throughout the subject areas were tested for the presence of lead-based paint. Coated surfaces meeting or exceeding the SCDHEC limit of 0.7 milligrams of lead per square centimeter (0.7 mg/cm2) were considered lead-based paint for the purpose of this assessment. Tested surfaces that exceeded the 0.7 mg/cm2 threshold include:
Beige metal window frames (1.30 to 13.10 mg/cm2).
Beige plaster pillars (14.50 to 16.00 mg/cm2).
Orange metal plate beneath window (3.60 mg/cm2).
4.0 Conclusions and Recommendations
The limited asbestos assessment of rooms 312, 320, 320A, 330, 351 and small conference room located on the third floor of Building 3 located at the Dorn VA Hospital located at 6439 Garners Ferry Road in Columbia, South
Carolina did not identify the presence of asbestos-containing materials.
4.1 Lead-Based Paint Conclusions
The limited lead-based paint assessment of the subject areas in Building 3 identified the presence of lead-based coatings on beige metal window frames, beige plaster pillars and orange metal plate beneath window.
Destructive actions to paint containing detectable levels of lead (e.g. paint preparation, component removal, demolition, sanding, grinding, burning, etc.) may require the contractor to comply with the standards of the OSHA regulations 29 CFR 1926.62 (Lead in Construction), including but not limited to training, initial exposure monitoring, the use of personal protective equipment, and medical surveillance. The determination of OSHA applicability is the responsibility of the contractor and dependent upon the paint condition and the planned treatment of the finishes.
The client is advised that OSHA does not recognize a threshold level of lead for definition purposes, only the presence or absence of lead. Consequently, the OSHA regulations governing worker protection for lead-based paint may apply to work practices including the disturbance of paint systems with detectable levels of lead.
Destructive actions (sanding, burning, demolition, component removal, paint preparation) to the lead-containing paint surfaces will require the contractor comply with the standards of OSHA, including but not limited to initial exposure monitoring, the use of personal protective equipment, and medical surveillance.
SCDHEC Regulation 61-107.19 permits demolition materials painted with lead-based paint (≥ 0.7 mg/cm2) to be disposed in a permitted Class Two (C&D) or Class Three Subtitle D, Municipal Solid Waste (MSW) landfill.
Accumulations of paint waste (chips, dust, or flakes) must be tested by the Toxicity Characteristic Leaching
Procedure (TCLP) to determine if the waste is classified as hazardous, which requires disposal in a Subtitle C
(hazardous waste) landfill. Lead waste, at a minimum, must be disposed in a Class Two or Three landfill.
6439 Garners Ferry Road Columbia, South Carolina 29209
S&ME Project No. 22610418
October 17, 2022 6
5.0 Limitations
This report is provided for the sole use of the Client. Use of this report by any other parties will be at such party’s sole risk, and S&ME disclaims liability for any such use or reliance by third parties. The results presented in this report are indicative of conditions only during the time of the sampling period and of the specific areas referenced. Under no circumstances is this report to be used as a bidding document, or as a project design or specification for removal of ACM.
S&ME performed the services in accordance with generally accepted practices of reputable environmental consultants undertaking similar studies at the same time and in the same geographical area. S&ME has endeavored to meet this standard of care. No other warranty, expressed or implied, is intended or made with respect to this report or S&ME’s services. Users of this report should consider the scope and limitations related to these services when developing opinions as to risks associated with the site. Additional limitations to our survey are as follows:
Significant destructive sampling was not performed during the asbestos assessment. Additional suspect
ACMs may be present in inaccessible locations such as in wall voids, pipe chases or flooring overlays.
Consequently, if additional suspect materials are discovered during future renovation or demolition activities, bulk samples must be collected and analyzed for asbestos content.
Appendices
Appendix I – Summary of Asbestos Sampling
Summary of Asbestos Sampling
Project Name: Building 3 – Third Floor Renovation, Dorn VA Hospital Project Number: 22610418
Location: 6439 Garners Ferry Road Columbia, South Carolina Sampling Date(s): September 28, 2022
NAD = No Asbestos Detected NA = Not Applicable SF = Square feet LF = Linear feet CF = Cubic Feet
1Category: F = Friable I = Category I, Non-Friable II= Category II, Non-Friable
2Type; Misc. = Miscellaneous Surf. = Surfacing TSI = Thermal System Insulation
3Condition: Good, Damaged or Significantly Damaged Accessible during renovation or demolition with Potential for Disturbance; Low or High
4Sample analyzed by TEM
Table I-I Summary of Asbestos Sampling
HOMOGENEOUS AREA SAMPLE DATA
HA
Area
Material
Description Material Location Quantity
1Cat
(F/I/II)
2Type
3Condition /
Potential for
Disturbance
Sample
Number Sample Location
Percent and Type
Asbestos
DW Drywall Various areas throughout rooms 950 SF NA Misc. NA/NA
DW-1 Room 351 NAD
DW-2 Room 312 NAD
DW-3 Room 320 NAD
JC Joint compound
Associated with drywall various areas throughout rooms
950 SF NA Surf. NA/NA
JC-1 Room 351 NAD
JC-2 Room 312 NAD
JC-3 Room 312 NAD
PL Plaster Rooms 312 & 320 50 SF NA Surf. NA/NA
PL-1 Room 312 NAD
PL-2 Room 312 NAD
PL-3 Room 320 NAD
DM Duct mastic Room 251 20 SF NA Misc. NA/NA
DM-1 Room 351 NAD
DM-2 Room 351 NAD
4DM-3 Room 351 NAD
BS Black sealant Exterior walls throughout rooms 1,200 SF NA Misc. NA/NA
BS-1 Room 312 NAD
BS-2 Room 351 NAD
4BS-3 Room 320 NAD
Abbreviations and Hazard Assessment Key
In accordance with the EPA and SCDHEC, a confirmed ACM is assigned a hazard assessment based on its present condition and potential for disturbance. The hazard assessment is used as a tool for prioritization in remedial actions regarding any identified ACM(s). The following key exhibits the criteria that compose the hazard assessment.
Present Condition
F = Friable G = Good (Very localized limited damage)
NF = Non-friable D = Damaged (Damage of less than 10% distributed and less than 25% localized)
SD = Significantly Damaged (Damage equal to or greater than 10% distributed, 25% localized)
Potential for Future Disturbance
LPD = Low Potential for Disturbance (Contact, Vibration, and Air Erosion all of Low Concern)
PD = Potential for Disturbance (Contact, Vibration, or Air Erosion of Moderate Concern)
SPD = Significant Potential for Disturbance (Contact, Vibration, or Air Erosion of High Concern)
Hazard Assessment
Significantly
Damaged
(SD)
Damaged
(D)
Good
(G)
SPD PD LPD SPD PD LPD
7 6 5 4 3 2 1
Appendix II – Floor Plan & Photographs
AutoCAD SHX Text
%%O%%UFIELD VERIFY DRAWING
AutoCAD SHX Text
THIRD FLOOR PLAN - 668
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A4
AutoCAD SHX Text N
AutoCAD SHX Text
OF
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET IN SET:
AutoCAD SHX Text
PROJECT TITLE:
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BUILDING:
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DRAWING:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
ORIG. BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SEAL:
AutoCAD SHX Text University of South Carolina
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
COLUMBIA, SC 29208
AutoCAD SHX Text
AND CONSTRUCTION
AutoCAD SHX Text
CAMPUS PLANNING
AutoCAD SHX Text
SEAL:
AutoCAD SHX Text
SQFT PLAN - THIRD FLOOR
AutoCAD SHX Text
SCHOOL OF MEDICINE V.A. #3
AutoCAD SHX Text
AutoCAD SHX Text
SF3
AutoCAD SHX Text
09MAY07
AutoCAD SHX Text
RLJ
AutoCAD SHX Text
AutoCAD SHX Text A4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
ST04
AutoCAD SHX Text
161 SF
AutoCAD SHX Text
EV02
AutoCAD SHX Text
59 SF
AutoCAD SHX Text H301
AutoCAD SHX Text
604 SF
AutoCAD SHX Text
ST01
AutoCAD SHX Text
177 SF
AutoCAD SHX Text H302
AutoCAD SHX Text
641 SF
AutoCAD SHX Text
AutoCAD SHX Text
COMM.
AutoCAD SHX Text
116 SF
AutoCAD SHX Text
AutoCAD SHX Text
ELEC.
AutoCAD SHX Text
131 SF
AutoCAD SHX Text
AutoCAD SHX Text
MECH.
AutoCAD SHX Text
156 SF
AutoCAD SHX Text
AutoCAD SHX Text
ELEC.
AutoCAD SHX Text
70 SF
AutoCAD SHX Text
AutoCAD SHX Text
COMM.
AutoCAD SHX Text
58 SF
AutoCAD SHX Text
ST03
AutoCAD SHX Text
222 SF
AutoCAD SHX Text
ST02
AutoCAD SHX Text
211 SF
AutoCAD SHX Text
EV01
AutoCAD SHX Text
58 SF
AutoCAD SHX Text 320A
AutoCAD SHX Text
137 SF
AutoCAD SHX Text 341A
AutoCAD SHX Text
150 SF
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
AutoCAD SHX Text
UPDATED PER LATEST WALK THROUGH
AutoCAD SHX Text
19MAY11
AutoCAD SHX Text
AutoCAD SHX Text
146 SF
AutoCAD SHX Text
AutoCAD SHX Text
114 SF
AutoCAD SHX Text
AutoCAD SHX Text
114 SF
AutoCAD SHX Text
AutoCAD SHX Text
112 SF
AutoCAD SHX Text
AutoCAD SHX Text
112 SF
AutoCAD SHX Text
AutoCAD SHX Text
293 SF
AutoCAD SHX Text V301
AutoCAD SHX Text
73 SF
AutoCAD SHX Text 306A
AutoCAD SHX Text
339 SF
AutoCAD SHX Text 306B
AutoCAD SHX Text
148 SF
AutoCAD SHX Text 306C
AutoCAD SHX Text
53 SF
AutoCAD SHX Text 306D
AutoCAD SHX Text
87 SF
AutoCAD SHX Text
AutoCAD SHX Text
114 SF
AutoCAD SHX Text
AutoCAD SHX Text
114 SF
AutoCAD SHX Text
AutoCAD SHX Text
117 SF
AutoCAD SHX Text H303
AutoCAD SHX Text
195 SF
AutoCAD SHX Text 301A
AutoCAD SHX Text
138 SF
AutoCAD SHX Text 301B
AutoCAD SHX Text
118 SF
AutoCAD SHX Text 301C
AutoCAD SHX Text
139 SF
AutoCAD SHX Text
AutoCAD SHX Text
2022 SF
AutoCAD SHX Text
AutoCAD SHX Text
UPDATED PER LATEST WALK THROUGH
AutoCAD SHX Text
03MAY16
AutoCAD SHX Text
AutoCAD SHX Text
UPDATED PER LATEST WALK THROUGH
AutoCAD SHX Text
02JUN17
AutoCAD SHX Text 301D
AutoCAD SHX Text
226 SF
AutoCAD SHX Text
AutoCAD SHX Text
1512 SF
AutoCAD SHX Text 360A
AutoCAD SHX Text
291 SF
AutoCAD SHX Text
AutoCAD SHX Text
978 SF
AutoCAD SHX Text
AutoCAD SHX Text
MECH.
AutoCAD SHX Text
179 SF
AutoCAD SHX Text
AutoCAD SHX Text
102 SF
AutoCAD SHX Text
AutoCAD SHX Text
113 SF
AutoCAD SHX Text
AutoCAD SHX Text
113 SF
AutoCAD SHX Text
AutoCAD SHX Text
465 SF
AutoCAD SHX Text 342A
AutoCAD SHX Text
394 SF
AutoCAD SHX Text
AutoCAD SHX Text
154 SF
AutoCAD SHX Text
AutoCAD SHX Text
397 SF
AutoCAD SHX Text
AutoCAD SHX Text
1352 SF
AutoCAD SHX Text H304
AutoCAD SHX Text
686 SF
AutoCAD SHX Text
AutoCAD SHX Text
78 SF
AutoCAD SHX Text 312A
AutoCAD SHX Text
9 SF
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING UPDATED - PER WALK THROUGH WITH JON CRAIN - USC SOM FACILITIES STAFF
AutoCAD SHX Text
21MAY18
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING UPDATED PER 2020 RENOVATION AS COORDINATED WITH USC SOM FACILITIES STAFF
AutoCAD SHX Text
20FEB20
AutoCAD SHX Text
FIXT_CODE
AutoCAD SHX Text
FU_TOTAL
AutoCAD SHX Text
FU_WASTE
AutoCAD SHX Text
FU_HOT
AutoCAD SHX Text
FU_COLD
AutoCAD SHX Text
AutoCAD SHX Text
306 SF
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
149 SF
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
111 SF
AutoCAD SHX Text
AutoCAD SHX Text
99 SF
vhacmscrosbS Polygon vhacmscrosbS Rectangle vhacmscrosbS Callout Visitor Center vhacmscrosbS Callout CERNER Solutions Architects vhacmscrosbS Rectangle vhacmscrosbS Rectangle vhacmscrosbS Callout CERNER Admin Support/Command Center vhacmscrosbS Callout Briefing Center vhacmscrosbS Rectangle vhacmscrosbS Callout
OIT SPACE
vhacmscrosbS Rectangle vhacmscrosbS Callout Small Conference Area/Ad Hoc Work Area vhacmscrosbS Rectangle vhacmscrosbS Callout Small Conference Area/Ad Hoc Work Area
Site Photographs VAMC COLSC- Building 3, Dorn VA Hospital
Columbia, South Carolina
S&ME Project 22610418
Taken by: BM & TK Date: September 28, 2022
1 General interior view. 2 Plaster tested negative for asbestos via PLM analysis. Beige plaster pillar tested positive for lead-based paint (14.50 – 16.00 mg/cm2).
3 Black sealant tested negative for asbestos via PLM and TEM analysis. Orange metal plate beneath window tested positive for lead-based paint (3.60 mg/cm2).
4 Duct mastic tested negative for asbestos via PLM and TEM analysis.
Site Photographs VAMC COLSC- Building 3, Dorn VA Hospital
Columbia, South Carolina
S&ME Project 22610418
Taken by: BM & TK Date: September 28, 2022
5 Drywall and associated joint compound tested negative for asbestos via PLM analysis. 6 Beige metal window frames tested positive for lead-based paint
(1.30 – 13.10 mg/cm2).
Appendix III – XRF Lead-Based Paint Reading Summary Table
Serial #95004
PAINT
Site: Building 3 - Dorn VA Hospital Date: September 28, 2022 Ranges (NEG<INC<POS): Device PCS
Reading
Number Floor/Area Room Feature Substrate Condition Color Result
XRF
Reading
(mg/cm²)
1 Shutter
2 Pre-Calibration 1.10
Pre-Calibration 1.00
Pre-Calibration 0.90
5 Interior Room 351 Window frame Metal Non-intact Beige Positive 4.00
6 Interior Room 351 Window Wood Intact White Negative <LOD
7 Interior Room 312 Window frame Metal Non-intact Beige Positive 13.10
8 Interior Room 312 Window Wood Intact White Negative <LOD
9 Interior Room 312 Pillar Plaster Non-intact Beige Positive 16.00
10 Interior Room 320 Window frame Metal Non-intact Beige Negative <LOD
11 Interior Room 320 Window frame Metal Non-intact Beige Positive 1.30
12 Interior Room 320 Window Wood Intact White Negative <LOD
13 Interior Room 320 Pillar Plaster Non-intact Beige Positive 14.50
14 Interior Room 320 Metal plate beneath window Metal Non-intact Orange Positive 3.60
15 Post-Calibration 1.10
16 Post-Calibration 1.10
17 Post-Calibration 0.90
Project No.: 22610418
XRF LEAD-BASED PAINT READING SUMMARY TABLE
Appendix IV – Asbestos Bulk Sample Analysis Sheets and Chain of
Custody Record
Columbia Office 134 Suber Rd.
Columbia SC 29210
Asbestos Analysis Summary
Client Job
Client Name
Date Analyzed
Date Received
10/3/2022
9/29/2022
Dorn VA Bldg 3 3rd Fl
9751 Southern Pine Boulevard
Charlotte, NC 28273
704-940-1830 Fax 704-565-4929
NVLAP Lab Code 102075-0
POLARIZED LIGHT MICROSCOPY
Performed by EPA 600/R-93/116 Method
Non-Asbestos Fibrous Non-Fibrous
Lab ID: Sample #: Appearance %/Type
Job Number 22610418
Asbestos Comments %/Type %/Type
3 CELLULOSE
2 GLASS
95 GYPSUM22-10927 DW-1 TAN/BEIGE FIBROUS ND
98 CELLULOSE
<1 GLASS
2 GYPSUM22-10928 DW-2 TAN/BEIGE FIBROUS ND
2 GLASS
<1 CELLULOSE
98 GYPSUM22-10929 DW-3 TAN/BEIGE FIBROUS ND
100 OTHER22-10930 JC-1 WHITE NONFIBROUS ND
For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not
Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.
The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion
Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response
Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None
Detected" for these materials is recommended.
Analyzed by: Jane Wasilewski Jane Wasilewski Laboratory Manager
Additional Comments: Issued 10/03/22
Non-Asbestos Fibrous Non-Fibrous
Lab ID: Sample #: Appearance %/Type
Job Number 22610418
Asbestos Comments %/Type %/Type
100 OTHER22-10931 JC-2 WHITE NONFIBROUS ND
100 OTHER22-10932 JC-3 WHITE NONFIBROUS ND
100 OTHER22-10933A PL-1 TAN NONFIBROUS NDMASTIC
100 OTHER22-10933B PL-1 WHITE NONFIBROUS NDSKIM COAT
100 OTHER22-10933C PL-1 GREY GRANULAR NDPLASTER
100 OTHER22-10934A PL-2 TAN NONFIBROUS NDMASTIC
For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not
Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.
The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion
Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response
Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None
Detected" for these materials is recommended.
Analyzed by: Jane Wasilewski Jane Wasilewski
Job Number 22610418
Asbestos Comments %/Type %/Type
100 OTHER22-10934B PL-2 WHITE NONFIBROUS NDSKIM COAT
100 OTHER22-10934C PL-2 GREY GRANULAR NDPLASTER
100 OTHER22-10935A PL-3 TAN NONFIBROUS NDMASTIC
100 OTHER22-10935B PL-3 WHITE NONFIBROUS NDSKIM COAT
100 OTHER22-10935C PL-3 GREY GRANULAR NDPLASTER
100 OTHER22-10936 DM-1 BEIGE PLIABLE ND
For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not
Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.
The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion
Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response
Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None
Detected" for these materials is recommended.
Analyzed by: Jane Wasilewski Jane Wasilewski
Job Number 22610418
Asbestos Comments %/Type %/Type
100 OTHER22-10937 DM-2 BEIGE PLIABLE ND
2 GLASS 98 OTHER22-10939 BS-1 BLACK NONFIBROUS ND
100 OTHER22-10940 BS-2 BLACK NONFIBROUS ND
For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not
Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.
The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion
Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response
Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None
Detected" for these materials is recommended.
Analyzed by: Jane Wasilewski Jane Wasilewski
EMSL Analytical, Inc.
10801 Southern Loop Blvd Pineville, NC 28134
Tel/Fax: (704) 525-2205 / (704) 525-2382 http://www.EMSL.com / charlottelab@emsl.com
EMSL Order: 412210009
Customer ID: SMEI54
Customer PO: 22610418
Project ID:
Attention: Jane Wasilewski Phone: (704) 940-1830
S&ME, Inc. Fax: (704) 565-4929
9771D Southern Pine Blvd. Received Date: 10/03/2022 1:35 PM
Charlotte, NC 28273 Analysis Date: 10/05/2022
Collected Date:
22610418Project:
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via
EPA/600/R-93/116 Section 2.5.5.1
Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types
DM-3
412210009-0001
Mastic Only White
Non-Fibrous
Homogeneous
100.0 None No Asbestos DetectedOther
BS-3
412210009-0002
Sealant Black
Non-Fibrous
Homogeneous
100.0 None No Asbestos DetectedOther
Analyst(s)
Derrick Young (2) Lee Plumley, Laboratory Manager or other approved signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. EMSL recommends that samples reported as none detected or <1% undergo additional analysis via PLM to avoid the possibility of false negatives.
Samples analyzed by EMSL Analytical, Inc. Pineville, NC
Initial report from: 10/06/2022 07:50:59
ASB_PLMEPANOB_0012_0002 Printed 10/6/2022 7:51:05AM Page 1 of 1
OrderID: 412210009
Appendix V – Copy of SCDHEC Inspectors’ Licenses
S&ME, Inc. | 134 Suber Road | Columbia, SC 29210 | p 803.561.9024 | www.smeinc.com
South Carolina Department of
Health and Environmental Control
Asbestos License
Travis Knight
| Insert from: "EHRM B3 Command Center Concept Plan - From Steve.pdf" |
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .