This federal contract opportunity notice is for renovations to domestic water piping projects at a Department of Veterans Affairs medical center. The solicitation number is 36C25821R0015 and proposals are due no later than August 28, 2021 at 2:00 PM Pacific Standard Time. Any requests for information must be submitted in writing to the listed points of contact no later than August 16. The opportunity is for project number 605-20-201 to renovate domestic water piping at the location. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22 is the contracting agency.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K
J
H
G
F
17 16 15 14 13 12 11 10 9 8.6 8.5 8.3 8 7.9
(E) 2 1/2" CW
(E) 1" CW
CW
HW
(E) 2" HW
(E) 3/4" CW
H W
(E) 3/4" HWR
(E) 3" CW
(E) 2 1/2" HW(E) 2 1/2" CW
(E) 2" HW
(E) 2 1/2" CW
(E) 2" HW
(E) 2" HW
(E) 1 1/4" HW
(E) 3/4" HWR
(E) 3" CW
(E) 3/4" CW
(E) 2" HW (E) 1 1/4" HW
(N) 2" CW
(E) 2" CW
HW
H W
(E) 3/4" CW
(E) 3/4" HW
(E) 2" HW
(E) 2" HW
(E) 2 1/2" CW
(E) 2" CW
(E) 2" HW
(E) 2" HW
(E) 2" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(N) 1" CW
(E) 3" CW
(N) 3/4" HWS
C W
R C
W H
W S
HWS
CW
HWS
CW
HWS
CW
HWS
CW
CW
(N) 1 1/2" HWS
(N) 1 1/4" HWS
(N) 1 1/4" HWS
(N) 1" HWS
(N) 1" HWS
(N) 1" HWS
(N) 2" HWS(N) 2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 1 1/2" CW (N) 1 1/2" CW
(N) 1 1/2" HWS
(N) 1" CW
(N) 1" HWS
SOV
SOV
SOV
SOV
SOV
SOV
SOV
SOV
SOV
SOV SOV
SOV
SOV
SOV SOV
SOV
SOV
SOV
(N) 2 1/2" CW
(N) 2" HWS
(N) 3/4" CW
(N) 2 1/2" CW
(N) 3/4" HWS
(N) 2 1/2" HWS
(E) 2 1/2" HW
(N) 2" HWS
(N) 2 1/2" CW
CW
HWS
CW
HWS
CW
HW
C W
2 2
(E) 2 1/2" CW
(E) 2" HW
SOV
(N) 2" CW
(N) 3/4" HWS
(N) 3/4" CW
SOV
(N) 3/4" CW(N) 3/4" HWS
SOV
H W
2 1
(N) 3/4" CW
(N) 2" CW
(N) 2" HWS
(N) 2" CW
(N) 1 1/2" HWS
(N) 2" CW
(N) 3/4" HWS
(N) 3/4" CW
SOV
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWR
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 1" HWS
2 2 1
(E) 3/4" HW
(E) 3" CW
(N) 3/4" CW
(N) 1" HWS
(N) 3/4" HWS
(N) 3/4" CW (N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" CWR
(N) 1" CW
(N) 1 1/2" CW
(E) 2 1/2" CW
(E) 2 1/2" CW
(N) 3/4" HWS
(N) 1" HWS
(N) 1 1/2" HWS
(N) 2" HWS
(N) 2" HWS
(N) 2 1/2" HWS
(N) 2" HWS
(N) 1 1/2" CW
SERVICE BAY
SB02-4
SERVICE BAY
SB02-6
PW-502
PW-502
(N) 1" CW
(N) 1" HWS
(E) 2" HW
(E) 2" HW
(N) 2 1/2" CW(N) 2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS(N) 2 1/2" CW
(N) 2" CW
(N) 2" CW
(N) 1 1/2" CW (N) 1 1/2" CW
(N) 3/4" CW
(N) 1 1/4" HWS
(N) 1 1/2" CW
(N) 1 1/4" HWS
(N) 1 1/2" CW
(N) 1 1/2" CW
(N) 1" CW
(N) 1 1/2" CW
(N) 2" HWS
(N) 1 1/2" CW
(E) 2" HW
(N) 1 1/2" CW
(N) 2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 2 1/2" CW
(N) 2 1/2" HWS
(N) 2 1/2" CW
WFM
WFM
CP
(E)
WFM
CP
WFM
(E)
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 4:
A
M
PW-204
NEW PARTIAL SECOND FLOOR PLAN #4 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DD
CC
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
TRUE
NORTH
N
GENERAL NOTES
1/8" = 1'-0"1 02 Water - Segment D New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
FINAL CONSTRUCTION DOCUMENTS 12/10/2020
26 71
STAFF TEAMING RM
2D-84
STAFF RESPITE AREA
2D-86
ON-CALL RM
2D-85
TOILET
2D-68A
TOILET
2D-66A
TOILET
2D-64A
TOILET
2D-62A
TOILET
2D-60A
TOILET
2D-58A
TOILET
2D-56A
TOILET
2D-54A
TOILET
2D-52A
TOILET
2D-50A
TOILET
2D-67A
TOILET
2D-65A
TOILET
2D-63A
TOILET
2D-61A
TOILET
2D-59A
TOILET BARIATRIC
2D-57A
SOILED UTILITY
2D-72
CLEAN UTILITY
2D-73
MEDICATION
2D-74
NOURISH
2D-80
STAFF TOILET
2D-82
STAFF TOILET
2D-81
EQUIPMENT STORAGE
2D-83
STAFF TL/SH
2D-85A
ICU 7
2D-68
ICU 8
2D-66
ICU 9
2D-64
ICU 10
2D-62
ICU 11
2D-60
ICU 12
2D-58
ICU 13
2D-56
ICU 14
2D-54
ICU 15
2D-52
ICU 16
2D-50
ICU 1 ISOLATION/ BARIATRIC
2D-57
ICU 2
2D-59
ICU 3
2D-61
ICU 4
2D-63
ICU 5
2D-65
ICU 6
2D-67
EQ ALC
C2-78A
EQ ALC
C2-79F
EQ ALC
C2-76D
CORR
C2-77
CORR
C2-78
CORR
C2-76
CORR
C2-79
CORR
C2-74
NURSE STATION
2D-78
PHYSICIAN
WORKROOM
2D-96
STRTCH/
EQUIP ALC
C2-78B C2-78C
PTS
2D-57E
26 25.5 25.4 25
F
E.5
E
D
C
E.9
24.9 24 23 22 21 20.5 20 19 18 17
(E) 1 1/2" HW
(E) 2 1/2" CW
HW
CW
(E) 3" CW
CW CW
HW
CW
(E) 2 1/2" CW
(E) 2" CW
(E) 2" HW
(E) 3" CW
CW
SERVICE BAY
SB02-7
PW-502
(N) 1 1/2" CW
SOV
(N) 3" CW
(N) 3" CW
(N) 3/4" CW
(N) 1 1/2" CW
(N) 3/4" CW
(N) 3/4" CW
(N) 3" CW
(N) 3/4" CW
(N) 3" CW
(N) 3/4" CW
(N) 3/4" CW (N) 3/4" CW
(N) 3/4" CW
(N) 1 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 1 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 3/4" CW
(N) 2 1/2" CW
(N) 3/4" CW
(N) 2 1/2" CW
(N) 1" CW
(N) 3/4" CW
(N) 1 1/2" CW
(N) 3/4" CW
(N) 2 1/2" CW
(N) 3/4" CW
(N) 1" CW
(N) 3/4" CW
(N) 2 1/2" CW
(N) 3/4" CW
(N) 2 1/2" CW
(N) 3/4" CW
(E) 2 1/2" CW
(N) 2" CW(N) 2" CW
(N) 3/4" CW
(N) 1" CW
(N) 2" CW
(N) 2 1/2" CW
(N) 1 1/2" CW(N) 3/4" CW
(N) 2" CW
(N) 2 1/2" CW
(N) 2" CW
(E) 3/4" CW
(E) 3/4" CW
(N) 1 1/2" CW
(N) 2" CW
(N) 3/4" CWR
(N) 3/4" CW
(N) 1 1/2" CW
(N) 1" CW
(N) 2" HWS
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 1 1/4" HWS
(N) 1 1/4" HWS
HWS
HW
WFM
WFM
CP
(E)
1 2
2 2
(N) 2" HWS
(N) 2" HWS
1 1
(E) 3/4" HW
(E) 3/4" HW
21 2 21 2 21 2 21 2 21
2 1
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 4:
A
M
PW-205
NEW PARTIAL SECOND FLOOR PLAN #5 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DD
CC
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
TRUE
NORTH
N
GENERAL NOTES
1/8" = 1'-0"1 02 Water - Segment E New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
27 71
E
D
C
16 15 14 13 12 11 10 9 8 7
(E) 3/4" HWR
(E) 2 1/2" HW
(N) 1 1/4" HWS
HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW2
(N) 2" CW
(N) 2" HWS
SOV
SOV
(N) 3/4" CW
(N) 3/4" CW
(N) 2 1/2" CW
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
SOVSOV
(N) 3/4" HWS
SOV
SOV
(N) 3/4" CW
(N) 3/4" CW
(N) 2 1/2" CW
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
SOV
(N) 3/4" HWS
(N) 3/4" HWS(N) 1" HWS
(N) 2 1/2" CW
(N) 2" CW
(N) 2 1/2" CW
1 1
2 2
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 1 1/2" CW
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW (N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
1 1
2 2
2 2
(N) 1 1/2" CW
(N) 1 1/2" CW
1 1
(N) 1 1/2" CW
(N) 1 1/2" CW
(N) 1 1/4" HWS
(N) 2" CW
(N) 3" CW
SERVICE BAY
SB02-8
PW-502
(E) 2" HW
HWS
CW CW
HWS
CW
HWS
CW
H W
S C
W
C W
H W
S
HWS
CW
HWS
CW
CW
HWS
H W
R C
W
(N) 1 1/2" CW
SOV
SOV
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" HWS
SOV
SOV
SOV
(N) 2" HWS
(N) 1 1/2" HWS
(N) 3/4" HWS
(N) 3/4" CW
(N) 1 1/4" HWS
(N) 1 1/2" HWS
HWS
CW
CW
HWS
C W
H W
S
H W
S C
W
H W
S C
W
H W
S C
W
H W
S C
W
(N) 3/4" CW
(N) 3/4" HWS
(N) 2 1/2" CW
(N) 3" CW
SOV
(N) 3/4" CW
(N) 3/4" HWS
(N) 1 1/2" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 2 1/2" CW
(N) 2" HWS
HWS
CWCW
HWS
HWS
CW
(N) 2 1/2" CW(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" HWS
(N) 1 1/2" CW
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" HWS
(N) 1 1/4" HWS
(N) 1" HWS
(N) 3/4" HWS
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 1 1/2" CW
(N) 1 1/2" CW
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" HWS
WFM
WFM
CP
(E)
(N) 2 1/2" CW
CW
HWS
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 5:
A
M
PW-206
NEW PARTIAL SECOND FLOOR PLAN #6 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DD
CC
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
TRUE
NORTH
N
GENERAL NOTES
1/8" = 1'-0"1 02 Water - Segment F New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
28 71
25.5
25.5
N N
M M
C C
D D
E E
F F
G G
H H
J J
K K
K.1 K.1
L L
PW-503
PW-503
PW-503
PW-503
PW-503
PW-503
PW-503
PW-503
PW-301
1 PW-302
PW-303
PW-304
PW-305
PW-306
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 5:
A
M
PW-300
OVERALL THIRD FLOOR PLAN RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
3/64" = 1'-0"1 OVERALL 03 - 3RD FLOOR PLAN - Waste & Vent - New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
29 71
26 25.5 25.4 25
N
M.5
M
L
K.1
24.9 24 23 22 21 20.5 20 19 18 17
(E) 3" CW
CW
HW
(E) 1/2" CW (E) 1 1/2" CW
(E) 3" CW
CW
(E) 3" CW
CW
(E) 2" HW
H W
(E) 2 1/2" HW
(E) 3/4" HWR
(E) 2 1/2" HW
(E) 2" HW
HW
(E) 1/2" HW
HW
(E) 2" HW
(E) 3" CW
(E) 2" HW
(E) 3/4" CW
H W
H W
(E) 2 1/2" HW
(E) 2 1/2" HW
(E) 3/4" HW
WHA
(E) 1 1/2" CW
(E) 1 1/2" CW (E) 3/4" HW
222222
CP
WFM
WFM
(N) 2 1/2" CW
(N) 2" CW
(N) 1" HWS
(N) 1" HWS (N) 1 1/2" HWS
(N) 1" CW (N) 2" CW
(N) 2" CW
(N) 2 1/2" CW
(N) 3" CW(N) 3/4" HWS
(N) 3" CW
PW-501
(E)
(N) 2" CW
(N) 1 1/2" HWS
(N) 1" HWS
(N) 1" CW
(N) 2 1/2" CW
(N) 1" HWS
(N) 1 1/2" HWS
(N) 2" CW (N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2" HWS
(E) 3/4" HW
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" CW
(N) 1 1/2" HWS
(N) 2" CW
(N) 1 1/2" HWS
(N) 2" HWS
(N) 3" CW
(N) 2" HWS
(N) 2" HWS
(N) 3" CW
(N) 3" CW
(N) 2" HWS
(N) 3/4" CW
(N) 1/2" CW
SOV
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 6:
A
M
PW-301
NEW PARTIAL THIRD FLOOR PLAN #1 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
TRUE
NORTH
N
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
GENERAL NOTES
1/8" = 1'-0"1 03 Water - Segment A New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
30 71
N
M.5
M
L
K.1
17 16 15 14 13 12 11 10 9 8.6 8.5 8.3 8 7.9
(E) 2 1/2" HW
(E) 3/4" HW
HW
CW
SO
V
H W
S C
W
HWS
CW
CW
HWS
(N) 1 1/2" CW
(N) 1" CW
(N) 1" HWS
H W
R C
W
(N) 3/4" HWR
(E) 3/4" HWR
(N) 2 1/2" CW (E) 2 1/2" CW
(N) 2" HWS
(E) 2" HW
(N) 2" HWS
(N) 2 1/2" CW
2 2
(N) 3/4" CW
(N) 3/4" HWS
11 2
22 2
2 2
2 1
SO
V
(E) 2" HW
(E) 3" CW
(N) 3/4" CW
(N) 1" HWS
(N) 1 1/2" HWS
(N) 2" HWS
(N) 1 1/2" HWS
(N) 2" CW
(N) 2 1/2" CW
(N) 2" CW
(N) 1 1/2" CW
(N) 2 1/2" CW
PW-502
WFM
WFM
CP
(E)
(N) 2 1/2" CW
(N) 2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" CW
(N) 2" HWS
(N) 2" CW
(N) 1 1/2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" CW
(N) 1 1/2" HWS
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 6:
A
M
PW-302
NEW PARTIAL THIRD FLOOR PLAN #2 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DD
CC
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
TRUE
NORTH
N
GENERAL NOTES
1/8" = 1'-0"1 03 Water - Segment B New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
31 71
J
H
G
F
24.9 24 23 22 21 20.5 20 19 18 17
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
HW
(E) 2" HW(E) 2" HW
HW
(E) 2" HW
HW HW
(E) 1" CW
CW
(E) 2 1/2" CW
CW
(E) 2 1/2" CW
CW
(E) 2 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 2" HW
(E) 2 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
C W
H W
(E) 2 1/2" CW
CW
HW
HWR
HW
(E) 2 1/2" CW
(E) 2" HW
(E) 3/4" HWR
(E) 3/4" CW
CW
HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 2 1/2" CW
(E) 3/4" HWR
(N) 2 1/2" CW
(N) 2" CW
HWR
CWR
H W
S C
W
HWS
CW
HWS
CW
CW
HWS
CW
(N) 1 1/2" HWS
(N) 1" HWS
(N) 2" HWS
(N) 3/4" CWR
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 3/4" HWS
(N) 1" HWS
(N) 1" HWS
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 2" HWS
(N) 1 1/2" CW
(N) 2" CW
(E) 3" CW
(N) 3" CW
(N) 2 1/2" CW(N) 3/4" CW
PW-501
PW-501
WFM
CP
WFM
(E)
CW
CP
WFM
WFM
(E)
(N) 2 1/2" CW
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 2" HWS
(N) 2" HWS
(N) 1 1/2" HWS
(N) 2" CW
(N) 2" CW
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 1" HWS
(N) 1 1/2" HWS
(N) 1 1/2" CW
(N) 3/4" CW
2 2
2 2
1 2
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 6:
A
M
PW-303
NEW PARTIAL THIRD FLOOR PLAN #3 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
TRUE
NORTH
N
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
GENERAL NOTES
1/8" = 1'-0"1 03 Water - Segment C New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
32 71
H
G
F
17 16 15 14 13 12 11 10 9 8.6 8.5 8.3 8 7.9
(E) 2" HW
(E) 3/4" HW
(E) 2" HW
H W
(E) 2" CW
(E) 3/4" HW
(E) 3/4" CW
C W
(E) 3" HW
(E) 3" CW
CW
HW
(E) 3/4" CW
(E) 3/4" HWR
(E) 3" HW
(E) 1 1/2" CW
(E) 1" CW
(E) 3/4" HW
HW
HWCW
(E) 3/4" HW
(E) 2" CW
(E) 3/4" HW
(E) 3/4" HW
H W
(E) 2" HW
(E) 2" HW
H W
(E) 2" CW
C W
(E) 3/4" HW
(E) 3/4" CW
C W
(E) 2" CW
C W
(E) 2" HW
SO
V
(N) 2" CW
(N) 2" CW
2 2
2 2
2 1
2 2
(N) 3/4" HWS
(N) 2" CW
HWS
CW
HWS
CW
(E) 3" CW
(N) 3" CW
SO
V
(E) 3" HW
(E) 3" HW
(N) 3" HWS
(E) 3" CW
(E) 2" HW
(N) 2" HWS
(N) 3" CW
(N) 2" HWS
(N) 2" CW
(N) 1 1/2" CW
(N) 2" HWS
(N) 3" CW
(N) 3" CW
(E) 3" HW
(E) 3/4" HWR
(N) 3/4" HWS
(N) 2" CW
(N) 1" HWS
(N) 1" HWS
SOV
SOV
(N) 3/4" CW
(E) 2" CW
(N) 2" CW
(N) 2" CW
(N) 3/4" CWR
(N) 1" HWS
(N) 3/4" HWS
(N) 1 1/2" HWS
(E) 2" HW
(N) 1" HWS
(N) 1 1/2" HWS
(N) 2" HWS
(N) 3" HWS
(N) 2" CW
(N) 3/4" HWS
(N) 1" HWS
(N) 3" CW
PW-501
PW-501
(N) 3/4" CW
CP
WFM
WFM
(E)
CP
WFM
WFM
(E)
(N) 3" HWS
(N) 3" CW
(N) 3" HWS
(N) 3" CW
(N) 2" CW
(N) 1" HWS
(N) 2" CW
(N) 2" CW
(N) 1" HWS
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 7:
A
M
PW-304
NEW PARTIAL THIRD FLOOR PLAN #4 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
TRUE
NORTH
N
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
GENERAL NOTES
1/8" = 1'-0"1 03 Water - Segment D New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
33 71
IMIM
F
E.5
E
D
C
E.9
24.9 24 23 22 21 20.5 20 19 18 17
C W
H W
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 2 1/2" HW
(E) 3/4" HWR
(E) 1/2" CW
(E) 3" CW
(E) 1 1/2" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3" CW
(E) 2" HW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 2" HW
(E) 2" HW
(E) 2" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3" CW
(E) 2" HW(E) 2" HW
(N) 2 1/2" CW (N) 2 1/2" CW
(N) 2" HWS
(N) 3/4" CW
2 2
(E) 1" CW
22 2
(E) 1/2" HW
2 1
(N) 3/4" HWS
(N) 1" HWS
(E) 2" HW
(N) 2" HWS
(N) 2" HWS
(N) 2 1/2" HWS
(N) 2" CW
(N) 2" CW
(E) 3" CW
PW-501
CWR
CW
HW
HWR
HWS
CW
HW
CW
HW
CWCW
HW
H
WC
W
CP
WFM
WFM
(E)
(N) 2 1/2" HWS
(N) 3" CW
(N) 3" CW
(N) 2 1/2" HWS
(E) 2 1/2" HW
(E) 2" CW
(N) 3" CW
(N) 2" HWS
(E) 3" CW
(E) 3" CW (E) 3/4" HW
(E) 3/4" HWR
(N) 2" CW
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 7:
A
M
PW-305
NEW PARTIAL THIRD FLOOR PLAN #5 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
TRUE
NORTH
N
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
GENERAL NOTES
1/8" = 1'-0"1 03 Water - Segment E New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
34 71
E.5
E
D
C
E.9
16 15 14 13 12 11 10 9 8.6 8.5 8.3 8 7.9
(E) 1 1/2" CW
(E) 2 1/2" HW
(E) 3/4" CW
(E) 2 1/2" HW
(E) 3" CW
(E) 3/4" HWR(E) 3" CW
(E) 3/4" HWR
(E) 3" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E ) 3
/4 " H
W
(E ) 3
/4 " C
W
(E) 1" HW(E) 3/4" HW
(E) 3/4" CW
(E) 1 1/4" HW
(E) 3" CW
CW
(E) 2 1/2" HW
HW
(E) 2" CW(E) 2" CW(E) 2" CW
(E) 3/4" CW
(E) 2 1/2" HW
(E) 1 1/2" CW
(E) 1 1/4" HW(E) 1 1/2" HW
(E) 3/4" CW
(E) 1" CW
(E) 2" HW
(E) 3/4" HW
(E) 1" HW
(E) 2 1/2" CW
(E) 3/4" CW
(E) 2" CW
(E) 2" CW
(E) 3" CW(E) 2 1/2" CW
(E) 2 1/2" HW
(E) 1" HW
(E) 2 1/2" HW
(E) 3/4" HW
(E) 2" HW(E) 2" HW
(E) 3/4" HW
2 2
2 2
(E) 1" CW
2 2
22 2
(E) 1 1/2" CW
(E) 2 1/2" HW
(N) 1 1/2" CW
(N) 2 1/2" HWS
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 2 1/2" CW
PW-502
WFM
CP
WFM
(E)
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 7:
A
M
PW-306
NEW PARTIAL THIRD FLOOR PLAN #6 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
TRUE
NORTH
N
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
GENERAL NOTES
1/8" = 1'-0"1 03 Water - Segment F New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
35 71
N N
M M
C C
D D
E E
F F
G G
H H
J J
K K
L L
PW-504
PW-504
PW-504
PW-504
PW-504
PW-504
PW-504
PW-504
PW-401
PW-402
PW-403
1 PW-404
PW-405
PW-406
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 8:
A
M
PW-400
OVERALL FOURTH FLOOR PLAN RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
3/64" = 1'-0"1 OVERALL 04 - 4TH FLOOR PLAN - Waste & Vent - New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
36 71
N.2
N
M.5
M
L
K.1
24.9 24 23 22 21 20.5 20 19 18 17
3/4"
H W
1 2
(N) 2" CW
(N) 1" HWS
(N) 1 1/2" HWS
(N) 2" HWS
(N) 1 1/2" HWS
(N) 1" HWS
(N) 3/4" HWS
(N) 1" CW
(N) 3/4" CW
(N) 2" CW
(N) 1" CW
(N) 2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2" HWS
PW-504
(N) 2 1/2" CW
(N) 2" HWS
(E) 2" HW
(E) 3/4" HWR
SERVICE BAY
SERVICE BAY
(N) 3" CW
WFM
WFM
CP
(E)
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 8:
A
M
PW-401
NEW PARTIAL FOURTH FLOOR PLAN #1 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
TRUE
NORTH
N
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
GENERAL NOTES
1/8" = 1'-0"1 04 Water - Segment A New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
37 71
N.2
N
M.5
M
L
K.1
17 16 15 14 13 12 11 10 9 8.6 8.5 8.3 8 7.9
(E) 3/4" HW
2 2
(N) 3/4" HWS
(N) 3/4" CW
(N) 2" HWS
(N) 1 1/2" HWS
(N) 2" HWS
(N) 1" HWS(N) 1 1/2" HWS
(N) 1" HWS
(N) 2" CW
(N) 2 1/2" CW
(N) 1" CW
(N) 2" CW
(N) 2 1/2" CW
(N) 2" CW
(N) 2 1/2" CW
PW-504
SERVICE BAY
SB04-2
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
WFM
WFM
(E)
CP
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 3" CW
(N) 1" HWS
(N) 3" CW (N) 1" HWS (N) 1" CW
(N) 1" HWS
(N) 1" CW
(N) 2 1/2" CW
(N) 2" HWS
(N) 2" HWS
(N) 2" HWS
(N) 2" CW
(N) 3" CW
(N) 1 1/2" HWS
(N) 3" CW
(N) 1 1/2" HWS
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 8:
A
M
PW-402
NEW PARTIAL FOURTH FLOOR PLAN #2 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
TRUE
NORTH
N
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
GENERAL NOTES
1/8" = 1'-0"1 04 Water - Segment B New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
38 71
J
H
G
F
24.9 24 23 22 21 20.5 20 19 18 17
(E) 3/4" HWR
H W
3"2"
CW
HW
(E) 3" CW
HW
3/4"
CW
(E) 2" HW
HWR
3/4"
CAPPED
CP
2 2 2 2 2
1 1
1 2
(N) 3/4" CW
(N) 2" CW
(N) 2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 3/4" HWS
(N) 1" HWS
(N) 2" HWS
(N) 2" HWS
(N) 3/4" CW
(N) 2 1/2" CW
(N) 3/4" HWS
(N) 1" HWS
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" CW
(N) 1" CW
(N) 2" CW
(N) 3" CWSERVICE BAY
SB004-05
PW-504
PW-504
WFM
3WFM
(E)
(E) 3/4" HW
CP
WFM
WFM
(E)
(N) 3" CW
(N) 1 1/2" HWS (N) 3" CW
(N) 1 1/2" HWS
(N) 3" CW
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 3" CW
(N) 1 1/2" HWS
(N) 3" CW
(N) 3/4" CW
(N) 3/4" CW
(N) 1 1/2" CW
(N) 1 1/2" HWS
(N) 3" CW
(N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2" HWS
(N) 3/4" CW
(N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 1" HWS
(N) 2 1/2" CW
(N) 1" HWS
(N) 2 1/2" CW
(N) 1" HWS
(N) 2" CW
(N) 2" HWS
(N) 2" CW
(N) 2" HWS
(N) 3/4" CW
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 3/4" CW
(N) 1" HWS
(N) 2 1/2" CW
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 9:
A
M
PW-403
NEW PARTIAL FOURTH FLOOR PLAN #3 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
TRUE
NORTH
N
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
GENERAL NOTES
1/8" = 1'-0"1 04 Water - Segment C New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
39 71
H
G
F
17 16 15 14 13 12 11 10 9 8.6 8.5 8.3 8 7.9
(E) 1/2" HW
(E) 3/4" HW
(E) 2" HW
(E) 2" HW
(E) 3/4" HWR
(E) 2" CW
(E) 3/4" CW
(E) 1" CW
(E) 1 1/2" CW
(E) 1" CW
(E) 1" HW
(E) 1" HW
HW
HWR
H W
HW
(E) 3/4" HW
(E) 2" CW
C W
H W
(E) 3" CW
(E) 3/4" CW
(E) 1" HW
HW
(E) 3/4" HW
(E) 3/4" HWR
HWR
HW
H W
C W
(E) 1" HW
(E) 2" CW
(E) 3/4" HW
(E) 2 1/2" HW
HW
3/4"
3/4"
3/4"
3/4"
3/4" 3/4" 3/4"
3/4"
3/4"
CW
3/4"
(E) 1" HW
1"
3/4"
(E) 3/4" HW
3/4"
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
CW
HW
(E) 3/4" HW
(E) 3/4" CW
1 1/2"
CW
(E) 3" CW
3/4"
2 2
HWS
2 2
2 2
1 2
CW
(N) 2" HWS
(N) 2" HWS
(N) 2" HWS
(N) 3" CW
(N) 1 1/2" HWS
(N) 1" HWS
(N) 1" HWS
2(N) 2" CW
(E) 1" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" CW
(N) 1 1/2" CW
(N) 1 1/2" CW
(N) 1 1/2" CW
(N) 1 1/2" CW
(N) 3/4" CW
(N) 3/4" HWS
(N) 2" CW
(N) 2" CW
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" HWS
(N) 3/4" HWS
(N) 3/4" CW
(N) 3/4" CW
(N) 3/4" HWR
(N) 1" HWR
(N) 1" CW
(N) 1" CW
(N) 1" HWS
(N) 1 1/2" HWS
(N) 1 1/2" CW
(N) 1 1/2" HWS
(N) 2" HWS
(N) 1 1/2" CW
(N) 2" CW
(N) 2 1/2" CW
SERVICE BAY
SB004-06
PW-501
PW-504
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" CW
(N) 1 1/2" HWS
SERVICE BAY
SB004-06
WFM
WFM
CP
(E)
WFM
WFM
(E)
CW
CWR
CP
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 9:
A
M
PW-404
NEW PARTIAL FOURTH FLOOR PLAN #4 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
TRUE
NORTH
N
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
GENERAL NOTES
1/8" = 1'-0"1 04 Water - Segment D New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
40 71
PATIENT
BEDROOM
4D-21
PATIENT
TOILET /
SHOWER
4D-21A
CORRIDOR
C4-80
WAITING
ALCOVE
4D-22
R
1- HO UR RATED W ALL
FLO O R DRAI N
CR W ALL M O UNTED CARD
READER
AREA O F BUI LDING NOT I N
SCO PE O F W O RK
LE G E N D :
2- HO UR RATED W ALL
4D-45
H/C BED ROOM
4D-45A
H/C TLT
4D-26
CONF-CLASS
SH04-9
SHAFT
4D-66
SOCIAL WORKERS
OFFICE
C4-75
CORR
4D-68
NURSE OFFICE
4D-67
INTERDISCIPLINARY
OFFICE
4D-69
LOUNGE
4D-05
CLEAN UTILITY
4D-04
CLEAN UTILITY
EL04-S8
ELEV
EL04-S7
ELEV
C4-70
CORR
SH04-8
SHAFT
AL
IG
N
CR
W3
PATIENT
BEDROOM
4D-21
PATIENT
TOILET /
SHOWER
4D-21A
CORRIDOR
C4-80
WAITING
ALCOVE
4D-22
R
1- HO UR RATED W ALL
FLO O R DRAI N
CR W ALL M O UNTED CARD
READER
AREA O F BUI LDING NOT I N
SCO PE O F W O RK
LE G E N D :
2- HO UR RATED W ALL
4D-45
H/C BED ROOM
4D-45A
H/C TLT
4D-26
CONF-CLASS
SH04-9
SHAFT
4D-66
SOCIAL WORKERS
OFFICE
C4-75
CORR
4D-68
NURSE OFFICE
4D-67
INTERDISCIPLINARY
OFFICE
4D-69
LOUNGE
4D-05
CLEAN UTILITY
4D-04
CLEAN UTILITY
EL04-S8
ELEV
EL04-S7
ELEV
C4-70
CORR
SH04-8
SHAFT
AL
IG
N
CR
W3
26 25.5 25.4 25
F
E.5
E
D
C
E.9
24.9 24 23 22 21 20.5 20 19 18 17
(E) 3/4" HW
(E) 2" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/4" CW
(E) 1 1/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HWR
(E) 3/4" CW (E) 1" HW (E) 1 1/4" HW
(E) 3/4" CW
(E) 3" CW
(E) 2 1/2" HW
(E) 3/4" HWR
HW
H W
C W
HW
HWR
HW (E) 3/4" HW
(E) 3/4" CW
(E) 1 1/2" CW(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
3 2
2 1
2 1
2 22
(E) 3/4" HW 2
2 2
1 1
(N) 3/4" HWS
C
W
(N) 3" CW
(N) 3" CW
(E) 3/4" CW
(E) 3/4" HW
(N) 3" CW
(N) 3" CW
(N) 1 1/2" CW
(N) 3" CW
(N) 3" CW
(N) 3" CW
(N) 3" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 1 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW (N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 2" CW
(N) 2" CW
(N) 2" CW
(N) 2" CW
(N) 3" CW
(N) 2 1/2" CW
(N) 2 1/2" CW(N) 2 1/2" CW
(N) 2 1/2" CW
(N) 1" HWS
(N) 1" HWS
(N) 2" CW
(N) 1 1/2" HWS
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 1 1/2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 2" HWS (N) 2" HWS
(N) 2" HWS
(N) 2 1/2" HWS
(N) 2 1/2" HWS
(N) 2 1/2" HWS
(N) 2 1/2" HWS
(N) 2 1/2" HWS
(N) 2 1/2" HWS
(N) 2 1/2" HWS
(N) 2 1/2" HWS
(N) 2 1/2" HWS
(N) 1" HWS
(N) 1" HWS
(N) 2 1/2" HWS
(N) 2 1/2" HWS
(N) 3" CW
(N) 2 1/2" HWS
(N) 2" HWS
(N) 2 1/2" CW
(N) 2" HWS
(N) 1 1/2" CW
SERVICE BAY
SB004-07
PW-501
WFM
WFM
CP
(E)
CWR
1. BRING NEW HOT AND COLD WATER LOOP WITHIN (6) SIX FEET OF
EXISTING POINT OF CONNECTION(S) TO AVOID CREATING A DEAD
LEG OR A DEAD END AT INTERSTITIAL SPACE. NO DEAD LEG/DEAD
ENDS SHALL BE ALLOWED PER VA DIRECTIVE.
2. HOT AND COLD WATER TO BE INSULATED AS PER INSULATION
CHART ON SHEET P001.
3. TO PREVENT STAGNATE WATER A LOOPING SYSTEM IS IN PLACE
TO PROVIDE A CONTINUOS FLOW.
4. FOR EXISTING PIPES THAT WILL BE REUSED, REMOVE ALL
EXISTING INSULATION AND REPLACE WITH NEW INSUALTION.
POC - CONNECT NEW COLD WATER TO EXISTING COLD
WATER IN INTERSTITIAL SPACE.
POC - CONNECT NEW HOT AND COLD WATER TO EXISTING
HOT /COLD WATER IN INTERSTITIAL SPACE.
3 SEE DETAIL "6 & 7" ON SHEET P-004. (TYPICAL)
4 RECIRCULATING PUMP IN INTERSTITIAL SPACE FOR DOMESTIC
COLD WATER LOOPING SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:4 9:
A
M
PW-405
NEW PARTIAL FOURTH FLOOR PLAN #5 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
KEY NOTES
TRUE
NORTH
N
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
W
O
K G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
I
M
Q
GENERAL NOTES
1/8" = 1'-0"1 04 Water - Segment E New
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
41 71
W1
W1W1 W1
W1W1 W1
W1 W1W1W1 W1
ANTEROOM
4D-50
PATIENT
BEDROOM
4D-12
PATIENT
BEDROOM
4D-11
PATIENT
BEDROOM
4D-10
PATIENT
BEDROOM
4D-14
PATIENT
BEDROOM
4D-13
PATIENT
BEDROOM
4D-15
PATIENT
BEDROOM
4D-17
PATIENT
BEDROOM
4D-20
PATIENT
BEDROOM
4D-16
PATIENT
BEDROOM
4D-18
PATIENT
BEDROOM
4D-19
PATIENT
BEDROOM
4D-21
PATIENT
BEDROOM,
BARIATRIC /
AIRBORNE
INFECTION
ISOLATION
4D-08
PATIENT
ISOLATION
BEDROOM
4D-09
BARIATRIC
PATIENT
BEDROOM
4D-07
BARIATRIC
PATIENT
BEDROOM
4D-06
BARIATRIC
PATIENT
TOILET /
SHOWER
4D-07A
BARIATRIC
PATIENT
TOILET /
SHOWER
4D-06A
PATIENT
TOILET /
SHOWER
4D-16A
PATIENT
TOILET /
SHOWER
4D-17A
PATIENT
TOILET /
SHOWER
4D-15A
PATIENT
TOILET /
SHOWER
4D-20A
PATIENT
TOILET /
SHOWER
4D-18A
PATIENT
TOILET /
SHOWER
4D-11A
PATIENT
TOILET /
SHOWER
4D-10A
PATIENT
TOILET /
SHOWER
4D-13A
PATIENT
TOILET /
SHOWER
4D-14A
PATIENT
TOILET /
SHOWER
4D-19A
PATIENT
TOILET /
SHOWER
4D-12A
TOILET /
SHOWER /
BARIATRIC,
PATIENT
ISOLATION
4D-08A
PHARMACIST
SHARED
OFFICE
4D-38
STORAGE,
EQUIPMENT
4D-39
CORRIDOR
C4-86
CORRIDOR
C4-81A
HALL1
RRIDOR
C4-80
CORRIDOR
C4-83A
HALL1
HAC
4D-40
WAITING
ALCOVE
4D-22
STAFF
LOUNGE
4D-37
SOILED
UTILITY
ROOM
4D-30
CONSULT
4D-24
NURSE
STATION
C4-85
HAC
4D-41 CLEAN
UTILITY
ROOM
4D-27
SHARED
OFFICE
4D-31
NURSE
MANAGER
OFFICE
4D-33
ASST
NURSE
MGR
OFFICE
4D-32
RECEPTION
4D-23
ALCOVE,
CRASH
CART
4H-33
ALCOVE,
GURNEY
4D-34
STORAGE
4D-35
NOURISHMENT
STATION
4D-29
MEDICATION
4D-28STAFF
TOILET
4D-42
STAFF
TOILET
4D-37A
CORRIDOR
C4-82
CORRIDOR
C4-84
CORRIDOR
C4-83
CORRIDOR
C4-86A
CORRIDOR
C4-81
HALL1
STORAGE
4D-36
RCA01
PATIENT
TOILET /
SHOWER
4D-9A
4C-25
RSRCH LAB
4D-26
CONF-CLASS
4D-25A
STAFF TLT
4D-26A
WAITING RM
4D-25B
SUPPLY RM
4C-28
OFFICE
SB04-8A
EQUIP RM
SB04-8
SERV BAY
C4-88
CORR
C4-89
CORR
C4-71
CORR
C4-30
OFFICE
4C-24
PROCEDURE ROOM
C4-71
CORR
C4-71
CORR
C4-71
CORR
C4-71
CORR
4C-28
OFFICE
4C-27
OFFICE
4C-29
OFFICE
SH04-7
SHAFT
MA04-23
CORR ST04-8
STAIR
4-70
ORR
EL04-T2
ELEV
4D-03
STORAGE
(E) LIGHTWELL
AL
IG
N
CR
CR
CR
W3 W3 W3 W3 W3 W3 W3 W3
W4
W1
W1W1 W1
W1W1 W1
W1 W1W1W1 W1
ANTEROOM
4D-50
PATIENT
BEDROOM
4D-12
PATIENT
BEDROOM
4D-11
PATIENT
BEDROOM
4D-10
PATIENT
BEDROOM
4D-14
PATIENT
BEDROOM
4D-13
PATIENT
BEDROOM
4D-15
PATIENT
BEDROOM
4D-17
PATIENT
BEDROOM
4D-20
PATIENT
BEDROOM
4D-16
PATIENT
BEDROOM
4D-18
PATIENT
BEDROOM
4D-19
PATIENT
BEDROOM
4D-21
PATIENT
BEDROOM,
BARIATRIC /
AIRBORNE
INFECTION
ISOLATION
4D-08
PATIENT
ISOLATION
BEDROOM
4D-09
BARIATRIC
PATIENT
BEDROOM
4D-07
BARIATRIC
PATIENT
BEDROOM
4D-06
BARIATRIC
PATIENT
TOILET /
SHOWER
4D-07A
BARIATRIC
PATIENT
TOILE…