S02 DWG FINAL SUBMITTAL-VOL1 PART B 22 Dec 20.pdf
PDF 18 MB Posted
- Attached to
- Z1DA--Service-Renovate Domestic Water Piping Projects FMS (VA-21-00001742)605-21-1-6043-0001-
- Solicitation number
- 36C25821R0015
About this file
This federal contract opportunity solicitation seeks proposals for the renovation of domestic water piping projects at a Department of Veterans Affairs medical center. Proposals are due no later than August 28, 2021 at 2:00 PM Pacific Standard Time. Questions regarding the solicitation are due by August 16, 2021 at 2:00 PM Arizona time and must be submitted in writing to the listed points of contact. The solicitation number is 36C25821R0015 and is for project number 605-20-201. The work involves renovating domestic water piping at the specified VA location.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K
N.2
N
M.5
M
L
K.1
17 16 15 14 13 12 11 10 9 8.6 8.5 8.3 8 7.9
(E) 2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1" HW
(E) 1" CW
(E) 3/4" HW
(E) 2 1/2" HW
(E) 3/4" CW
(E) 2 1/2" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 1" CW
(E) 1" HW
(E) 2" HW
(E) 3" CW (E) 3" CW
(E) 2" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 1" CW
(E) 1" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1" HW
(E) 2" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 2 1/2" CW
CW
HW
CW
(E) 1" CW
HW
CW
HW
H
W
CWCW
CW
HW
HW
CW
CW
(E) 3" CW(E) 3" CW
(E) 1 1/2" HW
(E) 1" HW
(E) 3" CW
(E) 1" CW
(E) 1" HW
CW
HW
CW
HW
CW
H W
CW
HW HW
CW CW
HW
H W
C W
H W
H W
C W
H W
C W
C W
H W
HW
C W
HW
C W
(E) 2" HW
HW
CW
(E) 4" CW
C W
(E) 1 1/2" CW
H W
(E) 2 1/2" HW
(E) 2 1/2" CW
(E) 1" CW
(E) 1" HW
(E) 3/4" HW
(E) 2" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 1" CW
(E) 3/4" HW
(E) 2 1/2" HW
(E) 2 1/2" HW
H W
(E) 2" CW
(E) 1 1/2" CW
(E) 2" HW
(E) 1" CW
(E) 3/4" HW
(E) 2" HW
(E) 2" CW
(E) 3/4" CW (E) 2" HW
(E) 2" CW
(E) 3/4" HW(E) 2" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 2" HW
(E) 2 1/2" HW
(E) 2 1/2" CW
(E) 2" HW
(E) 4" CW
(E) 2" CW
(E) 1 1/2" CW
(E) 2" HW
H W
H W
C W
(E) 2" HW
HW HW HW HW
C W
HW
H W
(E) 3/4" HW
(E) 1" HW
(E) 1" HWR
(E) 4" CW
(E) 2 1/2" HW
(E) 4" CW
(E) 2 1/2" HW
(E) 4" CW
HW
CW
HW
(E) 1" HW
(E) 1" HW
(E) 3/4" HW
(E) 3/4" HW
HWR
(E) 3/4" HW
H W
R C
W
HWCW
HW
H
W(E) 1" HW
(E) 3/4" HW
(E) 2" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1" CW (E) 1" CW
(E) 1 1/2" CW
(E) 1" CW
(E) 1/2" CW
(E) 1/2" HW
(E) 1/2" CW
H W
(E) 3/4" HW
(E) 3/4" CW
(E) 1" CW
(E) 1" HW
(E) 1" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 1" HW
C W
C W
(E) 1/2" HW
H W
C W
(E) 1" CW
H W
(E) 3/4" HW
(E) 3/4" CW
3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 1" HW
(E) 1" HW
(E) 1" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 1" HW
H W
(E) 1 1/2" CW
C W
(E) 1 1/2" CW
C W
(E) 1" CW
(E) 1" HW
(E) 1 1/4" HW(E) 1 1/4" HW
(E) 1 1/4" HW
(E) 2" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 1 1/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" CW
C W
H W
C W
HW
CW
(E) 1 1/4" HW
(E) 2" CW (E) 3/4" HW
(E) 3/4" CW
(E) 1" CW(E) 1" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 2" HW
(E) 1 1/4" HW
C W
(E) 1 1/2" CW
(E) 1" HW
CW
(E) 3/4" HW
(E) 3/4" HW
(E) 2" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HW(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 1" CW
(E) 2" HW
(E) 2" HW
H W
(E) 1" CW
(E) 1" HW
(E) 1" HW
(E) 1" CW
(E) 1" CW
C W
H W
(E) 3/4" HW
(E) 3/4" CW
(E) 1" CW
(E) 1" HW
CW
(E) 1" CW
(E) 3/4" CW
C W
(E) 2 1/2" CW
(E) 2" CW
(E) 1" CW
(E) 3/4" HW
(E) 1" CW
(E) 1" HW
(E) 3/4" CW
(E) 1" HW
(E) 1" CW
(E) 3/4" CW (E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 1" CW
(E) 1" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
HW
C W
(E) 3/4" CW
(E) 1" CW
(E) 3/4" HW
3/4" HW
3/4" CW
(E) 1" HW
(E) 2 1/2" CW
(E) 1" CW
(E) 1 1/2" CW
CAP
(E) 3/4" CW
C W
C W
(E) 1 1/2" CW
CAP
CAP
CAP
CAP
CAP
(E) 3" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" CW (E) 3/4" CW
(E) 1 1/4" HW
(E) 1" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 1 1/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW (E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
C W
CW
EQUIP RM
1B-20
COLD RM
1B-08
COLD RM
1B-09
SHOWER
1B-05
SECLUSION
1B-04A
TRAINING
1B-06
ARMORY
1B-04C
NCIC
1B-04B
WORK RM
1B-04DSTORAGE
1B-04E
BEDDING
1B-27A
CORR
C1-19
PROCEDURE
1B-10
ANIMAL WRD
1B-21
ANIMAL WRD
1B-22
ANIMAL WRD
1B-24
FEED
1B-27
STAIR
ST01-2
SHAFT
SH01-2
EQUIP RM
SB01-2A
SHOWER
1B-07
RECOVERY
1B-11
REFUGE RM
1B-12B
REFUGE RM
1B-12A
COLD RM
1B-25A
CGWSH-CLN
1B-26
CAGEWASH
1B-26B
EQUIP RM
1B-26A
NECROPSY
1B-25
CORR
C1-33
COLD RM
1B-17
LAUNDRY
1B-32
ANIMAL WRD
1B-29C
CIR
1B-29
PROCEDURE
1B-28E
DECON RM
1B-28D
ANIMAL WRD
1B-28C
AUTOCLAVE
1B-28H
BIOCHEM
1B-51H
CHEMICAL
1B-51A
WARD
1B-31
ANIMAL WRD
1B-30
ANIMAL WRD
1B-29B
CLEAN
1B-28A
ANIMAL SUR
1B-29F
PROCEDURE
1B-29G
ANTE ROOM
1B-28
MECH
1B-46B
OFFICE
1B-41
STORAGE
1B-48 RSRCH LAB
1B-40
EMS
1B-42
RADIATION SAFETY STORAGE
1B-44
RADIATION SAFETY STORAGE
1B-45
LAB
1B-51K
SOUND BOOTH
1B-51J SOUND BOOTH
1B-51B
OFFICE
1B-51C
SOUND BOOTH
1B-51G
ANIMAL WRD
1B-23
CGWASH-DRTY
1B-26C
STORAGE
1B-26D
STORAGE
1B-13
ANIMAL PRE
1B-14
DRESSING
1B-16
ANIMAL SUR
1B-16A1
ELEV LOB
C1-26
ELEVATOR LOBBY
1C-22A
REFRIGERA
1B-50B
LAB
1B-50A
CORR
C1-30
LAB
1B-50D
CORR
C1-29
EXPERIMENT
1B-19
KITCHEN
1B-18
ANIMAL WRD
1B-29D
ANIMAL WRD
1B-29A ANIMAL WRD
1B-28B
LAB
1B-49
RADIATION SAFETY STORAGE
1B-43
WORK RM
1B-50
LOUNGE
1B-52F
WASHING RM
1B-46
HSKPG
1C-20
OFFICE
1B-51F
CONF RM
1B-51D
CHIEF OFF
1B-40A
MECH RM
1B-42A
CORR
C1-34
CORR
C1-37
RABBIT-OAE
1B-51
WORK RM
1B-51
CORR
C1-22
CORR
C1-20
EMS
MA01-1
POL-SECUR
1B-04
BEDDING
1B-37
CORR
C1-21
DARK RM
1B-54
O.R.
1B-16B
CHIEF OFF
1B-02
SUPV OFF
1B-03
WORK RM
1B-50
OFFICE
1B-50C
MOUSE-OAE
1B-51I
SERVBAY
SB01-2
CORR
C1-17
PRI TOI
1A-627B
CORR
C1-08
TOILET
1A-629A
CORR
1C-22
POST DOCS
1B-51E
ELEV
EL01-T1
ANIMAL SUR
1B-16A
CAPPED
(E) 1 1/2" CW
VA POLICE
(E) 1" HW
(E) 3" CW
(E) 1" HWR
(E) 1" CW
SOV
MV
CAPPED
CW
HW
CAPPED
2 3
(E) 2" HW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:2 9:
A
M
PD-102
PARTIAL FIRST FLOOR PLAN #2 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
1/8" = 1'-0"1 01 Water - Segment B
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DDBB
CCAA
Y Z A1 A2
A3 A4
W
O
K
G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
M
Q
I
A5
TRUE
NORTH
N
GENERAL NOTES
DEMO KEY NOTES
POD - DEMO PIPE BACK TO MAIN. REMOVE ANY TEES AND/OR
ELBOWS TO PROVIDE PIPE WITH NO DEAD ENDS. (TYPICAL)
POD - EXISTING VALVE SHOWING SIGNS OF CORROSION.
DISCONNECT VALVE AND REPLACE WITH NEW VALVE.
(TYPICAL)
POD - DISCONNECT PIPE IN INTERSTITIAL SPACE AND PREPARE
FOR NEW CONNECTION. (TYPICAL)
EXISTING HOT, COLD WATER AND HOT WATER RETURN RISER.
1. WORK ON THIS FLOOR IN THIS AREA SHALL BE COORDINATED
WITH VA AND SHALL BE IN ACCORDANCE WITH THE PROPOSED
PHASING AS INDICATED ON THE PHASING NARRATIVE ON SHEET
P-001.
2. DEAD LEGS/DEAD ENDS TO BE REMOVED BACK TO MAIN AND
CAPPED.
3. ALL FIXTURES SHALL BE VERIFIED WITH PLANS AND ASSOCIATED
PIPING. ALL DEAD LEGS CAPPED IN INTERSTITIAL SPACE SHALL BE
VERIFIED AS DEAD LEGS AND NO USABLE FIXTURE ARE
CONNECTED TO SUCH PIPES PRIOR TO DEMOLITION/REMOVAL.
4. REMOVE ALL DEMO PIPE SUPPORTS ATTACHED TO BUILDING
STRUCTURE, PATCH AND REPAIR CONCRETE SURFACES WITH
ENGINEER CEMENT.
5. PROVIDE TEMPORARY SHUT OFF VALVES DURING PHASE
CONSTRUCTION.
6. ALL EXISTING PIPE INSULATION SHALL BE REMOVED AND
REPLACED FOR DOMESTIC HOT AND COLD WATER SYSTEM.
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
FINAL CONSTRUCTION DOCUMENTS 12/10/2020
32 6232 62
26 25.5 25.4 25
J
H
G
F
24.9 24 23 22 21 20.5 20 19 18 17
(E) 2" CW
(E) 1" HWR
HWR
(E) 3/4" CW
(E) 3/4" HW
H W
C W
(E) 1 1/2" HW
HW
CW
(E) 2" HW
(E) 3" CW (E) 1 1/2" HW
HW
(E) 2" CW
(E) 2" CW
(E) 1" HW
HW
C W
(E) 1 1/2" HW
HW
CW
(E) 1 1/2" HW (E) 1 1/2" HW
(E) 2 1/2" CW
HW
CW
C W
(E) 2 1/2" CW
(E) 2 1/2" CW
(E) 1" CW
HW HW
(E) 1 1/2" CW
(E) 1 1/4" HW
CW
HW
(E) 1 1/2" CW
(E) 1 1/4" HW
C W
H W
(E) 1" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 1 1/2" CW
(E) 1 1/4" HW
(E) 1 1/2" CW
(E) 3/4" CW
CW
(E) 3/4" HW
(E) 1" HW
C W
H
W (E) 3/4" CW
(E) 1 1/2" HW
(E) 1 1/2" HW
(E) 1 1/2" HW
(E) 2 1/2" CW
CW
HWHW
(E) 3" HW
(E) 4" CW
(E) 3/4" HW
(E) 3/4" HWR
(E) 3/4" HWR
H W
R
C W
C W
(E) 1 1/2" CW
(E) 1 1/4" HW
H W
(E) 1 1/2" CW
(E) 1 1/2" HW
(E) 1" CW
(E) 1 1/2" HW
HW
CW
HW
(E) 1 1/2" HW
(E) 2 1/2" CW
(E) 2" CW
(E) 1 1/2" HW
(E) 2" CW
C W
(E) 2" CW
C W
(E) 3/4" CW
(E) 3/4" HW
C W H
W
CW
HW
(E) 3/4" CW
(E) 3/4" HW
HW
CW
(E) 1 1/2" HW
(E) 1" CW H
W
C W
H W
C W
(E) 1" HW(E) 1" HW
(E) 1" HW
(E) 1 1/4" HW
HWHWHWHW
(E) 3/4" HW
(E) 1" CW
(E) 1" CW
(E) 1" CW
(E) 3/4" HW
(E) 3/4" CW
HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/4" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 1/2" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 2" CW
(E) 3/4" HW(E) 3/4" CW
H
WC
W
(E) 1" HW
CWCW
HW
H W
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
H W
(E) 1" CW
(E) 3/4" CW(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
CANTEEN
1A-03
SERVBAY
SB01-3
VAULT
1C-27C
CLINIC
1A-106
CLINIC
1A-107
OFFICE
1A-82C
TOILET
1A-82B
FELLOW OFFICE
1A-82H
OFFICE
1A-82K
OFFICE
1A-821
CORR
C1-41A
OFFICE
1A-79B
OFFICE
1A-76A
ANTEROOM
1A-76
WAITING
1A-102
EXAM
1A-84H
EXAM
1A-84J
EXAM
1A-84C
OFFICE
1A-84D
EXAM
1A-84E
EXAM
1A-84F
EXAM RM
1A-84G
WOMENS TOILET
1A-83A
MENS TOILET
1A-83B
EMS CLOSET
1A-84W
OFFICE
1C-25F
ASSIST OFF
1C-25G
SUBSTANCE
1C-25C
OFFICE
1A-84T OFFICE
1A-84Y
CAST RM 1
1A-84U
*Unnamed* 1A-84S
EXAM RM
1A-84R
EXAM
1A-84Q
EXAM RM
1A-84OEXAM
1A-84P
OPERATORS
1A-88
OFFICE
1A-02D
OFFICE
1A-02C
OFFICE
1A-02B
OFFICE
1A-02A
EXAM
1A-84I
INTAKE
1A-08
INTAKE
1A-09
LINEN
1C-28
SEW
1C-28A
OFFICE
1A-10
PATIENT EDUCATION
1A-05
OFFICE
1A-06
CLEAN
1C-27B
ELIGIBILITY OFFICE
1A-02I
ELIGIBILITY OFFICE
1A-02H ELIGIBILITY OFFICE
1A-02G
ELIGIBILITY OFFICE
1A-02J
*Unnamed* 1A-02K
WORK AREA
1A-84K
EXAM
1A-101
REST RM
1A-84X
PRI TOILET
1A-88A
LOCKER
1A-84V
DCNDT AFF
1F-01
SOCIAL WRK OFFICE
1F-02
PRPL HRT
1F-04
PAT ADVOC
1F-03
CORR
C1-49
OFFICE
1F-10A
REHAB
1F-05
FILE RM
1F-09A
OFFICE
1F-08A
AMER. LGN
1F-06
OFFICE
1F-08B
AGENT ORG
1F-08C
LAUNDRY
1F-19
PROGRAM MGR OFFICE
1F-07
*Unnamed*
SB01-5A
EED
1F-43
OFFICE
1F-03A
OFFICE
1F-03B
OFFICE
1F-09B
CHIEF OFF
1F-10B
OFFICE
1F-10C
OFFICE
1F-10D
OFFICE
1F-10F
OFFICE
1F-10E EXAM ROOM
1F-10G
Unoccupied Unoccupied
Unoccupied Unoccupied
Unoccupied Unoccupied
STAIR
ST01-4
Unoccupied Unoccupied
SHAFT
SH01-4
STORAGE
1A-02E
ELIGIBILITY OFFICE
1A-02F
CORR
C1-35
WOMENS PUBLIC RESTROOM
1A-101B
CAST ROOM
1A-84B
EXAM
1A-84NEXAM
1A-84M
SERVBAY
SB01-5
INTAKE
1A-11
LINEN
1C-28C
OFFICE
1A-82J
DUMBWATER
DW01-1
MAIL RM
1C-25
RESTROOM
1C-25B
ELEV LOB
C1-28
WAITING
1A-02
LOBBY
1A-01
ELEV
EL01-P1
ELEV
EL01-P2
OFFICE
1F-08
OFFICE
1F-09
CORR
C1-50
WAITING RM
1F-10
OFFICE
1A-82E
OFFICE
1A-82F
OFFICE
1A-82G
PHARMACY
1A-74
OFFICE
1A-82A
EXAM
1A-84L
CORR
C1-52
CORR
1A-84
CORR
C1-41
WAITING RM
1C-25D
OFFICE
1C-25E
ANTEROOM
1C-27A
CORR
C1-42
CORR
C1-53
CORR
C1-38D
LOBBY
C1-38
CORR
C1-12
EXAM RM
1A-07
PHARMACY
1C-25A
PHARMACY
1C-27
WAIT AREA
1A-84
Unoccupied Unoccupied
MY HEALTH VET SUPPORT
OFFICE
1A-04
CORR
C1-54
CORR
1A-92
OFFICE
1A-82D
CONF RM
1A-108
*Unnamed*
SB01-3A
HW
CW
CW
HW
(E) 1 1/2" CW
CAPPED
HOSE BIBB IN
INTESTINAL
SPACE.
(E) 3/4" CW
(E) 3/4" CW
(E) 1" CW
(E) 3/4" CW
CAPPED
CAPPED
(E) 3/4" HW
(E) 3/4" CW
(E) 1" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/4" HW
(E) 1" HW
CAPPE
D
CAPPED
(E) 3/4" HWR
CAPPED
CAPPED
(E) 1 1/4" CW
(E) 1" CW
(E) 1 1/4" CW
(E) 3/4" HWR
(E) 1 1/4" HW
(E) 2" CW
(E) 1" HW
(E) 1" HW
(E) 2" CW
(E) 3/4" HWR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:3 0:
A
M
PD-103
PARTIAL FIRST FLOOR PLAN #3 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
1/8" = 1'-0"1 01 Water - Segment C
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DDBB
CCAA
Y Z A1 A2
A3 A4
W
O
K
G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
M
Q
I
A5
TRUE
NORTH
N
GENERAL NOTES
DEMO KEY NOTES
POD - DEMO PIPE BACK TO MAIN. REMOVE ANY TEES AND/OR
ELBOWS TO PROVIDE PIPE WITH NO DEAD ENDS. (TYPICAL)
POD - EXISTING VALVE SHOWING SIGNS OF CORROSION.
DISCONNECT VALVE AND REPLACE WITH NEW VALVE.
(TYPICAL)
POD - DISCONNECT PIPE IN INTERSTITIAL SPACE AND PREPARE
FOR NEW CONNECTION. (TYPICAL)
EXISTING HOT, COLD WATER AND HOT WATER RETURN RISER.
1. WORK ON THIS FLOOR IN THIS AREA SHALL BE COORDINATED
WITH VA AND SHALL BE IN ACCORDANCE WITH THE PROPOSED
PHASING AS INDICATED ON THE PHASING NARRATIVE ON SHEET
P-001.
2. DEAD LEGS/DEAD ENDS TO BE REMOVED BACK TO MAIN AND
CAPPED.
3. ALL FIXTURES SHALL BE VERIFIED WITH PLANS AND ASSOCIATED
PIPING. ALL DEAD LEGS CAPPED IN INTERSTITIAL SPACE SHALL BE
VERIFIED AS DEAD LEGS AND NO USABLE FIXTURE ARE
CONNECTED TO SUCH PIPES PRIOR TO DEMOLITION/REMOVAL.
4. REMOVE ALL DEMO PIPE SUPPORTS ATTACHED TO BUILDING
STRUCTURE, PATCH AND REPAIR CONCRETE SURFACES WITH
ENGINEER CEMENT.
5. PROVIDE TEMPORARY SHUT OFF VALVES DURING PHASE
CONSTRUCTION.
6. ALL EXISTING PIPE INSULATION SHALL BE REMOVED AND
REPLACED FOR DOMESTIC HOT AND COLD WATER SYSTEM.
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
33 6233 62
J
H
G
F
17 16 15 14 13 12 11 10 9 8.6 8.5 8.3 8 7.9
H W
(E) 2" CW
(E) 2" CW
CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1" HW
(E) 2" CW
HW
CW
HW
CW
(E) 1" CW
(E) 1" HW
(E) 3/4" CW
(E) 3/4" HW
C W
H W
(E) 2" CW
HW
CW
(E) 2" CW
(E) 1" HW
HW
CW
(E) 2" CW
(E) 1" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
H W
C W
H W
(E) 3/4" HW
CW HW
(E) 3/4" CW
(E) 3" CW
(E) 2" HW
(E) 2 1/2" CW
(E) 2" HW
(E) 2" HW
(E) 1" CW
(E) 1" CW
(E) 3/4" HW (E) 2" CW
CWCW
HW HW
(E) 1" HW(E) 1" HW
(E) 1 1/2" HW
(E) 1 1/2" HW
(E) 3/4" HW
(E) 3/4" HW
HWHWHW
C W
(E) 1 1/2" CW
H W
C W
CW
(E) 3/4" CW
(E) 3" CW
CW
(E) 1" HWR
HWR
(E) 1" HW
(E) 1" HW
HW HW
(E) 1 1/2" CW
(E) 3/4" HW
HW
CW
(E) 1" HWR
H W
R C
W
CW
(E) 1 1/2" CW
(E) 1" HWR
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 1" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
CAP
CAP
(E) 1" HW
(E) 3/4" CW
(E) 1" CW
(E) 1/2" CW
(E) 1" CW
(E) 1" CW
(E) 1" CW
(E) 1" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" CW
CW
C W
CW
C W
(E) 3/4" CW
(E) 1" CW
(E) 1" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
C W
3/4"HW UP
3/4"HW DN
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 2" CW
(E) 2" HW
(E) 3/4" HW
(E) 2" HW
(E) 3/4" CW
(E) 3/4" HWC
W
(E) 1" CW
(E) 1" CW
H W
(E) 1" CW
(E) 3/4" CW
(E) 1" CW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 2" CW
C W
CW
CW
C W
(E) 1" HW
(E) 1" HW
H W
(E) 3/4" HW
HW
(E) 3/4" HW
1-1/2"CW
(E) 1" CW
C W
(E) 1" HW
(E) 1" HW
(E) 1" HW
(E) 1" HW
(E) 1" CW
(E) 1" CW
(E) 1" HW (E) 1" CW
H W
(E) 1" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
H W
(E) 1/2" HW
EMS ADMIN OFFICE
1C-24A
EMS CHIEF
1C-24B
EMS OFFICE
1C-24
OFFICE
1C-18
MAIL RM
1C-04G
SHOP/BIO-MED
1C-04F
ELEV
EL01-S4
OFFICE
1C-14C
SUPPLY RM
1C-30B
EYE WASH
1C-32C
STORAGE
1C-15A
TECH OFF
1C-15
SHAFT
SH01-3
SERVBAY
SB01-4
EQUIP RM
SB01-4A
CHIEF OFF
1C-14A
SHAFT
SH01-8
EQUIP RM
SB01-6A
STAIR
ST01-5
EMS CLOSET
1C-01
PUB TOILET
1C-03
VEST
1C-03*
PUB TOILET
1C-02
OFFICE
1C-04A
DUMBWAITER
DW01-2
MECH
1C-26D
STORAGE
1C-26C
STORAGE
1C-26B
TRANSITION
1C-26F
SUPPLY ROOM
1C-26
EMS CLOSET
1C-32B
WIPE DN RM
1C-26F
SHAFT
SH01-6
Unoccupied Unoccupied
Unoccupied Unoccupied
ELEV
EL01-B2
DMBWTR ACC
1C-31
LOUNGE
1B-52F
ASSIST OFF
1C-04D
MTRL MGMNT
1C-04B
CHIEF OFF
1C-04C
MAIL RM
1C-25
ELEV LOB
C1-18
CORR
C1-37
RECEIVING
1C-16
CONTROL RM
1C-17
CORR
C1-40
WAREHOUSE
1C-04
DISH
1C-33A
PREP RM
1C-26A
STERILIZER
1C-28B
STORAGE
1C-14A
REPRODUCT
1C-03A
WASHING RM
1C-26E
DECON RM
1C-32
NETWORK RM
1C-04X
ELECTRICAL
PHRM CACHE
1C-04A
Unoccupied Unoccupied
STAFF TOI
1C-32C
LOCKERS
1C-32A
CORR
C1-43
LOCKSMITH
1C-14B
CORR
C1-46
CORR
C1-44
CORR
C1-45
SERVBAY
SB01-6
CORR
C1-47
NOURISH ST
1C-32D
ELEV
EL01-S5
C W
(E) 3" CW
CAPPED
(E) 3/4" HW
3 3
(E) 1 1/4" CW
(E) 1 1/4" HW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:3 0:
A
M
PD-104
PARTIAL FIRST FLOOR PLAN #4 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
1/8" = 1'-0"1 01 Water - Segment D
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DDBB
CCAA
Y Z A1 A2
A3 A4
W
O
K
G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
M
Q
I
A5
TRUE
NORTH
N
GENERAL NOTES
DEMO KEY NOTES
POD - DEMO PIPE BACK TO MAIN. REMOVE ANY TEES AND/OR
ELBOWS TO PROVIDE PIPE WITH NO DEAD ENDS. (TYPICAL)
POD - EXISTING VALVE SHOWING SIGNS OF CORROSION.
DISCONNECT VALVE AND REPLACE WITH NEW VALVE.
(TYPICAL)
POD - DISCONNECT PIPE IN INTERSTITIAL SPACE AND PREPARE
FOR NEW CONNECTION. (TYPICAL)
EXISTING HOT, COLD WATER AND HOT WATER RETURN RISER.
1. WORK ON THIS FLOOR IN THIS AREA SHALL BE COORDINATED
WITH VA AND SHALL BE IN ACCORDANCE WITH THE PROPOSED
PHASING AS INDICATED ON THE PHASING NARRATIVE ON SHEET
P-001.
2. DEAD LEGS/DEAD ENDS TO BE REMOVED BACK TO MAIN AND
CAPPED.
3. ALL FIXTURES SHALL BE VERIFIED WITH PLANS AND ASSOCIATED
PIPING. ALL DEAD LEGS CAPPED IN INTERSTITIAL SPACE SHALL BE
VERIFIED AS DEAD LEGS AND NO USABLE FIXTURE ARE
CONNECTED TO SUCH PIPES PRIOR TO DEMOLITION/REMOVAL.
4. REMOVE ALL DEMO PIPE SUPPORTS ATTACHED TO BUILDING
STRUCTURE, PATCH AND REPAIR CONCRETE SURFACES WITH
ENGINEER CEMENT.
5. PROVIDE TEMPORARY SHUT OFF VALVES DURING PHASE
CONSTRUCTION.
6. ALL EXISTING PIPE INSULATION SHALL BE REMOVED AND
REPLACED FOR DOMESTIC HOT AND COLD WATER SYSTEM.
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
34 6234 62
26 25.525.4 25
F
E.5
E
D
C
24.9 24 23 22 21 20.5 20 19 18 17
(E) 2 1/2" CW
(E) 1" HW
(E) 2 1/2" HW
(E) 2" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 2 1/2" CW
(E) 2" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3" CW
(E) 2" HW
CW
HW
(E) 3" CW
(E) 2" HW
CW
HW
(E) 1 1/2" CW
(E) 3/4" HWR
C
W H
W R
(E) 1 1/2" CW
(E) 2 1/2" CW
C W
H W
(E) 3/4" HWR
(E) 3" CW(E) 3/4" HWR
C W
H W
R
(E) 1" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
HW
HW HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW(E) 3/4" HW
(E) 1" HW
(E) 2" CW
(E) 2" CW
(E) 2" CW
(E) 1" HW
(E) 1 1/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 3/4" HW(E) 2" CW
(E) 1 1/2" CW(E) 3/4" HW
(E) 2" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 1 1/4" CW(E) 2" CW
(E) 3/4" HW
CW CWCWCW
HW HW
C W
C W
(E) 1 1/2" HW
(E) 2 1/2" HW
H W
C W
(E) 3/4" CW
H W
(E) 3/4" CW
(E) 3/4" HW
(E) 3" CW
CW
HW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3" CW
(E) 1" HW
CW
HW
(E) 1 1/2" CW
(E) 3/4" HW(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 2 1/2" CW
H W
C W
(E) 1 1/2" HW
(E) 1 1/4" HW
(E) 2" CW
(E) 3/4" HW
(E) 3" CW
(E) 1 1/2" CW
(E) 2 1/2" CW
(E) 1 1/2" HW
(E) 3" CW
(E) 2" HW
(E) 3/4" CW
H W
CW
HW
CW
HW
(E) 3/4" HW
(E) 3/4" CW
(E) 4" CW
(E) 2" HW (E) 3" CW
H W
C W
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1" HW
(E) 2" CW
(E) 1" HW
H W
(E) 1" HW
(E) 1 1/2" CW
(E) 1" HW
(E) 1 1/2" HW
(E) 3/4" HW(E) 3/4" HW
(E) 1 1/2" HW
(E) 2 1/2" CW
(E) 3/4" HW
(E) 1" HW
(E) 3/4" HW
(E) 3/4" CW
CAPPED
(E) 2" CW
(E) 3/4" HW
(E) 1" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3" CW
(E) 1 1/2" HW
CAPPED CAPPED
(E) 3/4" HW
CAPPED
(E) 1" HW (E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
HWHW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
CAPPED
(E) 1 1/2" HW
(E) 1 1/2" HW
PAT TOIL
1E-37A
PAT TOIL
1E-56A
PAT RM 4B
1E-56
PAT TOIL
1E-54A
PAT ROOM 2B
1E-55
PAT RM 2B
1E-54
PAT RM 2B
1E-53
PAT TOIL
1E-52A
PAT RM 2B
1E-52
PAT TOIL
1E-51A
PAT RM 1B
1E-51
PAT TOIL
1E-48A
PAT RM 1B
1E-50
PAT RM 4B
1E-48
CLEAN UTIL
1E-35
SOILED UTI
1E-36
STOR
C1-72
PAT RM 2B
1E-37
OFFICE
1E-58
STORAGE
1E-59
OFFICE
1E-60
OFFICE
1E-61
PRI TOI
1E-62
OFFICE
1F-37B
AMVETS OFF
1F-39A
CORR
1F-39
VFW OFFICE
1F-41
OFFICE
1F-42
CHIEF OFF
1F-37A
CONF RM
1E-30
LAUNDRY
1E-32KITCHEN
1E-33
STAFF TOIL
1F-36
STAFF TOI
1F-40
BREAK RM
1E-24A
RESTROOM
1E-46
CONG BATH
1E-47
RESTROOM
1E-49
EMS
1F-29A
MEDIT-CHPL
1F-29B
CORR
C1-65
SACRISTY
1F-30A
OFFICE
1F-31
OFFICE
1F-32
CHIEF OFF
1F-33
OFFICE
1F-34
SECRETARY
1F-34A
OFFICE
1F-35
UTIL RM
1F-35A
CORR
C1-68
RESTROOM
1F-38B
OFFICE
1F-38C
CORR
C1-55
STORAGE
1F-38A
AUDITORIUM
1F-38
STORAGE
1F-20
HEALTH SERVICES
1F-22
STAFF LCKR
1F-21
STAFF TOI
1F-21A
ELEV
EL01-S8
ELEV
EL01-S7
ELEV
EL01-S6
STAIR
ST01-6
SIGNAGE RM
1C-36
PAT EFFECT
1F-24
MECH RM
1C-34
SECRETARY
1F-37C
STORAGE
1F-35B
PAT TOIL
1E-50A
EQUIP RM
SB01-7A
CORR
C1-56
DAV OFFICE
1F-39C
DAV OFFICE
1F-39B
STAFF TOI
1F-22A
STAFF LCKR
1F-23
MEDIT CHPL
1F-30
MED RM
1E-34*
NURSE STAT
1E-34
CORR
C1-60
CORR
C1-48
CORR
C1-57
CORR
C1-57A
CORR
C1-58
CORR
C1-59
CORR
C1-69
WAITING RM
C1-92
STAIR
ST01-7
SHAFT
SH01-10
THERAPY ROOM
1E-63
STAFF LCKR
1F-25
STAFF LCKR
1F-26 CORR
C1-62
SERVBAY
SB01-7
ELEV LOBBY
C1-61
(E) 3/4" CW
3 3
3 3 3
6 6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:3 1:
A
M
PD-105
PARTIAL FIRST FLOOR PLAN #5 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
1/8" = 1'-0"1 01 Water - Segment E
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DDBB
CCAA
Y Z A1 A2
A3 A4
W
O
K
G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
M
Q
I
A5
TRUE
NORTH
N
GENERAL NOTES
DEMO KEY NOTES
POD - DEMO PIPE BACK TO MAIN. REMOVE ANY TEES AND/OR
ELBOWS TO PROVIDE PIPE WITH NO DEAD ENDS. (TYPICAL)
POD - EXISTING VALVE SHOWING SIGNS OF CORROSION.
DISCONNECT VALVE AND REPLACE WITH NEW VALVE.
(TYPICAL)
POD - DISCONNECT PIPE IN INTERSTITIAL SPACE AND PREPARE
FOR NEW CONNECTION. (TYPICAL)
EXISTING HOT, COLD WATER AND HOT WATER RETURN RISER.
REMOVE EXISTING INSULATION AND PREPARE FOR NEW
INSULATION.
POD - DEMO PIPE AND CAP IN INTERSISTIAL SPACE FOR ANY
PIPE NOT BEING RECONNECT TO THE NEW LOOP.
1. WORK ON THIS FLOOR IN THIS AREA SHALL BE COORDINATED
WITH VA AND SHALL BE IN ACCORDANCE WITH THE PROPOSED
PHASING AS INDICATED ON THE PHASING NARRATIVE ON SHEET
P-001.
2. DEAD LEGS/DEAD ENDS TO BE REMOVED BACK TO MAIN AND
CAPPED.
3. ALL FIXTURES SHALL BE VERIFIED WITH PLANS AND ASSOCIATED
PIPING. ALL DEAD LEGS CAPPED IN INTERSTITIAL SPACE SHALL BE
VERIFIED AS DEAD LEGS AND NO USABLE FIXTURE ARE
CONNECTED TO SUCH PIPES PRIOR TO DEMOLITION/REMOVAL.
4. REMOVE ALL DEMO PIPE SUPPORTS ATTACHED TO BUILDING
STRUCTURE, PATCH AND REPAIR CONCRETE SURFACES WITH
ENGINEER CEMENT.
5. PROVIDE TEMPORARY SHUT OFF VALVES DURING PHASE
CONSTRUCTION.
6. ALL EXISTING PIPE INSULATION SHALL BE REMOVED AND
REPLACED FOR DOMESTIC HOT AND COLD WATER SYSTEM.
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
35 6235 62
E.5
E
D
C
16 15 14 13 12 11 10 9 8.6 8.5 8.3 8 7.9 7
(E) 1" HW
(E) 3/4" CW
(E) 3/4" HW
CW
HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3" HW
(E) 2" HW
H W
C W
(E) 1 1/2" CW
(E) 2" HW
(E) 2" CW
(E) 2" HW
(E) 3" CW
(E) 3/4" HW
(E) 1 1/2" CW (E) 3/4" HW(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 1 1/2" CW (E) 3/4" HWR
(E) 3" CW
(E) 3/4" HWR
(E) 3" CW
H W
R C
W
CW
HW
CW
HWHW
CW
(E) 3" HW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 2" HW
(E) 1 1/2" CW
(E) 2" HW
(E) 1 1/2" CW
(E) 1 1/4" CW
(E) 3" HW
(E) 3/4" HW
(E) 1" CW
(E) 3/4" HW (E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
CW
HW
CW
HW
(E) 2" HW
(E) 3/4" HW
(E) 3/4" HW
H W
HW
(E) 3/4" CW
(E) 1 1/2" CW
(E) 3/4" CW
HWR
(E) 1" HWR
H W
R
(E) 1" HWR
H W
R
(E) 2" CW
(E) 2" HW
CW
HW
(E) 2" CW
(E) 1" HWR
HWR
HW
(E) 1" HWR
HWR
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
C W
(E) 1 1/2" HW
(E) 1 1/2" HW
(E) 1" HW
(E) 1" HW
(E) 1" HW
(E) 1" HW
(E) 1" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 1/2" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 2" CW
CWCWCW
(E) 2" HW
HW HW
(E) 2" HW
HW
H W
C W
(E) 2" CW
(E) 2" CW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 1" HW
(E) 1" HW
(E) 2" HW
(E) 1 1/2" HW
H W
(E) 1 1/2" HW
H W
(E) 1" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 2 1/2" CW
(E) 2" HW (E) 3/4" CW
(E) 2 1/2" CW (E) 2 1/2" CW
(E) 3/4" HW
(E) 3/4" HW
CAPPE
D
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
CW HW
SHAFT
SH01-9
REFRIGERA
1C-07BTRASH
1C-07C
STORAGE
1C-07A
RESTROOM
1E-111
PAT RM 2B
1E-112
PAT RM 2B
1E-110
PRI TOI
1E-62 MED RM
1E-01
RESTROOM
1E-13
REHAB CARE CO ORDER
OFFICE
1E-15
MED RM
1E-17
MNGR OFF
1E-18
PAT RM 1B
1E-107
MECH
1E-108
MECH RM
1E-109
PAT TOIL
1E-19A
CLEAN UTIL
1E-14
OFFICE
1C-11
STORAGE
1C-12
SOILED UTI
1E-16
PAT RM 2B
1E-19
STAFF OFFICE
1E-05A
WORK RM
1E-05B
PAT TOIL
1E-07A
PAT TOIL
1E-06A
PAT RM 2B
1E-09
PAT RM 2B
1E-08
PAT TOIL
1E-08A
PAT RM 2B
1E-10
HOPTL BATH
1E-10A
HOPTL BATH
1E-12A
PAT RM 2B
1E-11
PAT RM 4B
1E-12
STORAGE
1C-08
MECH
1C-09
FREEZER
1C-33J
REFRIGERA
1C-33H
REFRIGERA
1C-33K
FREEZER
1C-33L
REFRIGERA
1C-33M
EMS
1C-33F
EMS
1E-04
CONG BATH
1E-03
SUPV OFF
1C-37E
OFFICE
1C-37B
HALL
STORAGE
1C-33R
ELEV
EL01-T2
INFO CTR
1C-37
CHIEF
1C-37A
CORR
C1-51
STORAGE
1E-33F
CONTROL RM
1C-33E
CORR
1C-37D
CHIEF OFF
1C-06
OFFICE
1C-06A
CORR
C1-65A
CORR
1C-07
CORR
C1-67
NURSE STAT
C1-66
CORR
C1-75
*UNNAMED*
1E-109A
STAIR
ST01-8
VESTIBULE
SHAFT
SH01-11
KITCHEN
1E-02
STORAGE
1C-38
CORR
C1-62
CORR
C1-73
CORR
C1-64
CORR
C1-63
WAREHOUSE
1C-05
FREEZER
1C-33G
CORR
C1-79
KITCHEN/NUTRITION/FOOD
SERVICE
1C-33
SERVBAY
SB01-8
CAPPED
STEAM
HEAT
EXCHANGE
R
(E) 1" HW
3 3
(E) 3/4" HW
(E) 1 1/2" CW
(E) 1" HWR
(E) 2" HW5
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:3 1:
A
M
PD-106
PARTIAL FIRST FLOOR PLAN #6 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
1/8" = 1'-0"1 01 Water - Segment F
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DDBB
CCAA
Y Z A1 A2
A3 A4
W
O
K
G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
M
Q
I
A5
TRUE
NORTH
N
GENERAL NOTES
DEMO KEY NOTES
POD - DEMO PIPE BACK TO MAIN. REMOVE ANY TEES AND/OR
ELBOWS TO PROVIDE PIPE WITH NO DEAD ENDS. (TYPICAL)
POD - EXISTING VALVE SHOWING SIGNS OF CORROSION.
DISCONNECT VALVE AND REPLACE WITH NEW VALVE.
(TYPICAL)
POD - DISCONNECT PIPE IN INTERSTITIAL SPACE AND PREPARE
FOR NEW CONNECTION. (TYPICAL)
EXISTING HOT, COLD WATER AND HOT WATER RETURN RISER.
REMOVE EXISTING INSULATION AND PREPARE FOR NEW
INSULATION.
POD - DEMO PIPE AND CAP IN INTERSISTIAL SPACE FOR ANY
PIPE NOT BEING RECONNECT TO THE NEW LOOP.
DOMESTIC HOT AND COLD WATER PIPING INTO MECHANICAL
ROOM. FIELD VERIFY EXACT LOCATION.
1. WORK ON THIS FLOOR IN THIS AREA SHALL BE COORDINATED
WITH VA AND SHALL BE IN ACCORDANCE WITH THE PROPOSED
PHASING AS INDICATED ON THE PHASING NARRATIVE ON SHEET
P-001.
2. DEAD LEGS/DEAD ENDS TO BE REMOVED BACK TO MAIN AND
CAPPED.
3. ALL FIXTURES SHALL BE VERIFIED WITH PLANS AND ASSOCIATED
PIPING. ALL DEAD LEGS CAPPED IN INTERSTITIAL SPACE SHALL BE
VERIFIED AS DEAD LEGS AND NO USABLE FIXTURE ARE
CONNECTED TO SUCH PIPES PRIOR TO DEMOLITION/REMOVAL.
4. REMOVE ALL DEMO PIPE SUPPORTS ATTACHED TO BUILDING
STRUCTURE, PATCH AND REPAIR CONCRETE SURFACES WITH
ENGINEER CEMENT.
5. PROVIDE TEMPORARY SHUT OFF VALVES DURING PHASE
CONSTRUCTION.
6. REMOVE ALL EXISTING PIPE INSULATIONS AND REPLACE WITH
NEW.
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
36 6236 62
1H01
VESTIBULE
C
E.9
C.3
C.2
B.9
B.3
A.6
A.1
1.1 2.1 3.1 4.1 5.1 5.5 6.1
B
(E) 1 1/2" CW
(E) 3/4" HW
(E) 1" HW
(E) 1" HW
(E) 1 1/2" CW
(E) 2" CW
(E) 1" HW
(E) 1" HW
(E) 2" CW
(E) 1" HW
(E) 1" HW (E) 2 1/2" CW
(E) 2 1/2" CW
(E) 1" HW
(E) 2 1/2" HW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 1 1/2" CW
H W
C W
(E) 1 1/2" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3" HW
(E) 2" HW
H W
C W
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1 1/2" CW
C W
C W
(E) 3" HW
C W
C W
H W
H W
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW (E) 3/4" HW
(E) 3/4" HWR
(E) 3/4" CW
(E) 1" CW
(E) 3/4" HWR
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HWR
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 3/4" HWR (E) 1" HW
(E) 3/4" HW
(E) 2" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HWR
(E) 3/4" HW
(E) 3/4" CW
(E) 1" HW
(E) 3/4" HWR
(E) 3/4" HW
(E) 3/4" HWR
(E) 3/4" HW
(E) 3/4" HWR
(E) 2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HWR
(E) 1" HW
(E) 2" CW
(E) 3/4" HWR
(E) 1 1/2" HW
(E) 3/4" HWR
(E) 3/4" HW
(E) 2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HWR
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HWR
MECH
1E-65
EMS
1E-67
EMS
1E-68
PAT TOIL
1E-44A
PAT TOIL
1E-42A
PAT TOIL
1E-38A
PAT TOIL
1E-37A
PRI TOI
1E-149A
PAT TOIL
1E-148A
STAIR
MA01-87
BREAK RM
1E-149
PAT RM 2B
1E-148
PAT RM 2B
1E-146
PAT RM 2B
1E-145
MNGR OFF
1E-78
SOCIAL WRK
1E-77
LAUNDRY
1E-76
DIR OFF
1E-81
RESTROOM
1E-73
RESTROOM
1E-74
MECH
1E-75
STORAGE
1E-79
COURT
CY01-1
PAT RM 2B
1E-82
PAT RM 4B
1E-48 SOILED UTI
1E-36
STOR
C1-72
PAT RM 2B
1E-38
PAT RM 2B
1E-40
PAT TOIL
1E-40A
PAT RM 2B
1E-42
PAT RM 2B
1E-44
PAT TOIL
1E-45A
MECH
1E-66
PAT RM 2B
1E-37
OFFICE
1E-43
STORAGE
1E-43A
RECREATION
1E-41
STORAGE
1E-31
OFFICE
1E-57A
OFFICE
1E-57
OFFICE
1E-58
OFFICE
1E-64A
STORAGE
1E-64C
RECREATION
1E-64B
MED RM
1E-17
MNGR OFF
1E-18
MNGR OFF
1E-20
DIR OFF
1E-22
SOCIAL WRK OFFICE
1E-24
CONF RM
1E-26
BREAK RM
1E-28
PAT TOIL
1E-29A
PAT TOIL
1E-27A
PAT TOIL
1E-25A
PAT TOIL
1E-23A
PAT TOIL
1E-21A
PAT TOIL
1E-19A
PAT RM 2B
1E-21
PAT RM 2B
1E-23
PAT RM 2B
1E-25
PAT RM 27
1E-27
EMS
1E-80
SOILED UTI
1E-16
PAT RM 2B
1E-19
CORR
C1-74
PAT RM 2B
1E-29
CORR
C1-77CORR
C1-71
CORR
C1-87
PAT LGE
1E-70A
THERAPY ROOM
1E-63
CORR
C1-86
CORR
C1-85
DIETITIAN
1E-69
PAT TOILET
1E-70
DINING
1E-64
RECREATION
1E-64*
PAT RM 2B
1E-45
1 (E) 3/4" CW
(E) 3/4" HW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:3 1:
A
M
PD-107
PARTIAL FIRST FLOOR PLAN #7 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
1/8" = 1'-0"1 01 Water - Segment Y
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DDBB
CCAA
Y Z A1 A2
A3 A4
W
O
K
G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
M
Q
I
A5
TRUE
NORTH
N
GENERAL NOTES
DEMO KEY NOTES
POD - DEMO PIPE BACK TO MAIN. REMOVE ANY TEES AND/OR
ELBOWS TO PROVIDE PIPE WITH NO DEAD ENDS. (TYPICAL)
POD - EXISTING VALVE SHOWING SIGNS OF CORROSION.
DISCONNECT VALVE AND REPLACE WITH NEW VALVE.
(TYPICAL)
POD - DISCONNECT PIPE IN INTERSTITIAL SPACE AND PREPARE
FOR NEW CONNECTION. (TYPICAL)
EXISTING HOT, COLD WATER AND HOT WATER RETURN PIPE.
REMOVE EXISTING INSULATION AND PREPARE FOR NEW
INSULATION.
1. WORK ON THIS FLOOR IN THIS AREA SHALL BE COORDINATED
WITH VA AND SHALL BE IN ACCORDANCE WITH THE PROPOSED
PHASING AS INDICATED ON THE PHASING NARRATIVE ON SHEET
P-001.
2. DEAD LEGS/DEAD ENDS TO BE REMOVED BACK TO MAIN AND
CAPPED.
3. ALL FIXTURES SHALL BE VERIFIED WITH PLANS AND ASSOCIATED
PIPING. ALL DEAD LEGS CAPPED IN INTERSTITIAL SPACE SHALL BE
VERIFIED AS DEAD LEGS AND NO USABLE FIXTURE ARE
CONNECTED TO SUCH PIPES PRIOR TO DEMOLITION/REMOVAL.
4. REMOVE ALL DEMO PIPE SUPPORTS ATTACHED TO BUILDING
STRUCTURE, PATCH AND REPAIR CONCRETE SURFACES WITH
ENGINEER CEMENT.
5. PROVIDE TEMPORARY SHUT OFF VALVES DURING PHASE
CONSTRUCTION.
6. ALL EXISTING PIPE INSULATION SHALL BE REMOVED AND
REPLACED FOR DOMESTIC HOT AND COLD WATER SYSTEM.
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
37 6237 62
C
E.9
E.3
D.9
D.6
C.9
C.7
C.3
C.2
B.9
B.3
A.6
A.1
6.5 7.1 7.5 8.1 8.4 9.1 9.5 10.1
11.2
11.7
12.2 13.1
(E) 3/4" HWR
(E) 3/4" HW
(E) 2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HWR
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HWR
(E) 3/4" HW
(E) 2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HWR
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HWR
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HWR
(E) 3/4" HW
(E) 2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HWR
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW (E) 3/4" HW (E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 2" HW
(E) 3/4" HWR
(E) 2 1/2" CW
(E) 2" HW
(E) 3/4" HWR
(E) 2" CW
(E) 2" HW
(E) 3/4" HWR
(E) 2" CW
(E) 3/4" HWR
(E) 3/4" CW
C W
(E) 1 1/2" CW
H W
R H
W
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
HW
CW
(E) 1" HW
(E) 2" CW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 2" HW
(E) 3" CW
(E) 1" HWR
CW
H W
H W
R C
W C
W H
W R
H W
(E) 3/4" CW
(E) 2" CW
(E) 3" CW
(E) 2" HW
(E) 1" HWR
(E) 3" CW
(E) 1" CW
(E) 3" CW
(E) 1" HWR
(E) 2" HW
(E) 3" CW
(E) 2" HW
(E) 1" HWR
HW
(E) 1" HW
PAT TOIL
1E-145A
PAT TOIL
1E-142A
PAT RM 2B
1E-145
PAT RM 2B
1E-143
PAT RM 2B
1E-142
PAT TOIL
1E-139A
PAT RM 2B
1E-139
PAT RM 2B
1E-137
PAT RM 2B
1E-136
RESTROOM
1E-136A
NOURISH ST
1E-130STORAGE
1E-133
PAT TOIL
1E-83 PAT TOIL
1E-86
PAT TOIL
1E-89 PAT TOIL
1E-92
REPORT RM
1E-134
MECH
1E-131
MED RM
1E-132
RESTROOM
1E-128
RESTROOM
1E-120
RESTROOM
1E-117
RESTROOM
1E-114
SOILED UTI
1E-124
CLEAN UTILITY
1E-122
PAT RM 2B
1E-119
PAT RM 2B
1E-118
PAT RM 1B
1E-116
PAT RM 2B
1E-115
PAT RM 29
1E-113
PAT RM 2B
1E-112
PAT RM 2B
1E-82
PAT RM 2B
1E-84
PAT RM 2B
1E-85
PAT RM 2B
1E-87
PAT RM 2B
1E-88
PAT RM 2B
1E-90
PAT RM 2B
1E-91
PAT RM 2B
1E-93
STORAGE
1E-95
RESTROOM
1E-96
PAT ROOM 2B
1E-98
RESTROOM
1E-99
PAT RM 2B
1E-100
PAT RM 1B
1E-101
RESTROOM
1E-102
RESTROOM
1E-106
RESTROOM
1E-105
PAT RM 1B
1E-104
PAT RM 1B
1E-103
PAT RM 1B
1E-107
MECH
1E-108
MED RM
1E-123
PAT RM 2B
1E-121
CONG BATH
1E-97
CORR
C1-91
WATING ROOM
C1-89
CORR
C1-88
CORR
C1-87
EMS
1E-125
FAMILY DINING
IE-127
PAT RM 2B
1E-140
(E) 2" CW
(E) 1" HW
(E) 3/4" HWR
(E) 2" CW
(E) 1" HW
(E) 3/4" HWR
(E) 3/4" HW
(E) 3/4" CW
(E) 1" HWR
(E) 2" HW5
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:3 2:
A
M
PD-108
PARTIAL FIRST FLOOR PLAN #8 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
1/8" = 1'-0"1 01 Water - Segment A1
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DDBB
CCAA
Y Z A1 A2
A3 A4
W
O
K
G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
M
Q
I
A5
TRUE
NORTH
N
GENERAL NOTES
DEMO KEY NOTES
POD - DEMO PIPE BACK TO MAIN. REMOVE ANY TEES AND/OR
ELBOWS TO PROVIDE PIPE WITH NO DEAD ENDS. (TYPICAL)
POD - EXISTING VALVE SHOWING SIGNS OF CORROSION.
DISCONNECT VALVE AND REPLACE WITH NEW VALVE.
(TYPICAL)
POD - DISCONNECT PIPE IN INTERSTITIAL SPACE AND PREPARE
FOR NEW CONNECTION. (TYPICAL)
EXISTING HOT, COLD WATER AND HOT WATER RETURN RISER.
REMOVE EXISTING INSULATION AND PREPARE FOR NEW
INSULATION.
1. WORK ON THIS FLOOR IN THIS AREA SHALL BE COORDINATED
WITH VA AND SHALL BE IN ACCORDANCE WITH THE PROPOSED
PHASING AS INDICATED ON THE PHASING NARRATIVE ON SHEET
P-001.
2. DEAD LEGS/DEAD ENDS TO BE REMOVED BACK TO MAIN AND
CAPPED.
3. ALL FIXTURES SHALL BE VERIFIED WITH PLANS AND ASSOCIATED
PIPING. ALL DEAD LEGS CAPPED IN INTERSTITIAL SPACE SHALL BE
VERIFIED AS DEAD LEGS AND NO USABLE FIXTURE ARE
CONNECTED TO SUCH PIPES PRIOR TO DEMOLITION/REMOVAL.
4. REMOVE ALL DEMO PIPE SUPPORTS ATTACHED TO BUILDING
STRUCTURE, PATCH AND REPAIR CONCRETE SURFACES WITH
ENGINEER CEMENT.
5. PROVIDE TEMPORARY SHUT OFF VALVES DURING PHASE
CONSTRUCTION.
6. ALL EXISTING PIPE INSULATION SHALL BE REMOVED AND
REPLACED FOR DOMESTIC HOT AND COLD WATER SYSTEM.
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
38 6238 62
1H201
1H21
OR
STORAGE
EXIT
VESTIBULE
A.1
13.1
PAT TOILET
1G113A
PAT TOILET
1G109A
PAT TOILET
1G117A
PAT TOILET
1G111A
PAT TOILET
1G107A
PAT TOILET
1G101A
PAT TOILET
1G103A
LAUNDRY
1G-143
WOMEN'S
1G-141
MEDS
1G-116
CLEAN UTILITY
SOILED UTILITY
1G-112
ELEC
1G-135
COMM
1G-110
DIETICIAN OFFICE
1G-132
CLINIC OFFICE
1G-134
ADA/ABA RESIDENT ROOM
1G148
STAFF LOCKER/LOUNGE
1G-102
STAFF RESTROOM
1G102A
CONFERENCE ROOM
1G-136
PAT TOILET
1G144A
PAT TOILET
1G148A
PAT TOILET
1G146A
PAT TOILET
1G140A
RESIDENT ROOM
1G140
OFFICE
1G-138
PAT TOILET
1G121A
PAT TOILET
1G119A
PAT TOILET
1G123A
PAT TOILET
1G127A
ADA/ABA RESIDENT ROOM
1G127
ADA/ABA RESIDENT ROOM
1G123
RESIDENT ROOM
1G121
MEN'S
1G-118
HOUSEKEEPING
1G-120FAMILY KITCHEN
1G124
MEDITATION
1G126
RESIDENT ROOM
1G119
RESIDENT ROOM
1G101
RESIDENT ROOM
1G103
BARIATRIC ROOM
1G105
RESIDENT ROOM
1G117
RESIDENT ROOM
1G113
RESIDENT ROOM
1G109
RESIDENT ROOM
1G111
PAT TOILET
1G105A
BARIATRIC ROOM
1G107
MECHANICAL
1G-131
ADA/ABA RESIDENT ROOM
1G146
RESIDENT ROOM
1G144
TV/LIVING
1G-130
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
(E) 3/4" CW
(E) 1 1/4" CW
(E) 1/2" CW
(E) 1/2" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 2 1/2" CW
(E) 3/4" HW
(E) 2 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 2 1/2" CW
(E) 1 1/2" HW
(E) 1 1/4" HW
(E) 2 1/2" CW
(E) 1 1/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 1 1/2" CW (E) 3/4" CW
(E) 1 1/4" HW
(E) 2 1/2" CW
(E) 1" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 2 1/2" CW
(E) 1 1/4" HW
(E) 1" CW
(E) 1" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 1" HW
(E) 2 1/2" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1" HW
(E) 2 1/2" CW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 2 1/2" CW
(E) 3/4" HW
(E) 1 1/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 2 1/2" CW
(E) 3/4" HW
(E) 2 1/2" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 2 1/2" CW
(E) 3/4" HW
(E) 2" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 2" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 2" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3/4" CW
(E) 3/4" HW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:3 2:
A
M
PD-109
PARTIAL FIRST FLOOR PLAN #9 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
1/8" = 1'-0"1 01 Water - Segment A3
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DDBB
CCAA
Y Z A1 A2
A3 A4
W
O
K
G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
M
Q
I
A5
TRUE
NORTH
N
GENERAL NOTES
DEMO KEY NOTES
1. THIS AREA IS NEWLY CONSTRUCTED, CONTRACTOR TO VERIFY
EXISTING HOT/COLD WATER AND HOT WATER RETURN PIPING
HAS PROPER INSULATION. PROVIDE BID ALTERNATE TO ADD
INSUALTION IN THIS ARE AND PRICING FOR FIELD VERIFICATION.
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
39 6239 62
PTS
1H120B1H122-B
1H120
1H05-A 1H05
1H03-A
1H06-B1H06-A
1H03-B
1H20
1H117-A 1H117
1H115 1H115-A
1H113-A 1H113
1H109 1H109-A
1H107-A 1H107
1H127-A
1H105
1H103
1H03
1H202
1H204
1H206
1H208
1H210
1H212
1H214
1H216
1H218
1H203 1H205
1H207
1H122
1H071H11
1H06
1H211 1H215
1H213 1H09
1H217 1H219
1H121-A1H123-A1H125-A
1H06-C
1H1211H1231H1251H1271H129
1H129-A1H131-A
1H131
TOILET 12TOILET 13
RESIDENT 12
NURSE CORR
NURSE
NURSENURSE
NURSE
STAFF
CORRIDOR
TOILET 07
RESIDENT
RESIDENT 08
TOILET 08
TOILET 09
RESIDENT 09
RESIDENT 10
TOILET 10
TOILET 11 RESIDENT 11
KITCHEN
MULTIPURPOSE
CORR
CONCIERGE
LAUNDRY RM
SOILED UTILITY
ELECTRICAL RM
ELECTRICAL
OFFICE
COMM
CLEAN
UTILITY
MEDICATION
STAFF
LOCKERSTF
TLT
HK/EMS
STORAGE
TRANSITION RM
CORRCORR
CORR
OFFICE
CC
CLINICAL
WORKRM
CORR
LIVING RM
STORAGE
TOILET 01TOILET 02TOILET 03
NURSE
RESIDENT
BARIATRIC 01
RESIDENT 02RESIDENT 03RESIDENT 04
TOILET 04
RESIDENT 05
TOILET 05TOILET 06
RESIDENT 06
FEC
FEC
FEC FEC
FEC
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
O A V
N O A V
N O A V
N O A V
N O A V
N O A V
NOAV
NOAV
NOAV
NOAV
NOAV
FEC
LADDER
ROOF ACCESS
FEC
PYXIS
N O A V
N O A V
32" FLAT SCREEN
32" FLAT SCREEN
D o o r is re v e rs ib le to a ll o w ri g h t o r le ft h a n d s w in g
20.5 20 19 18 17 16 15
1.1 2.1 3.1 4.1 5.1 5.5
(E) 2" CW
(E) 1 1/2" HW
(E) 1 1/2" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 2 1/2" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 1/2" CW
(E) 3" CW
(E) 1/2" CW
(E) 1" HW
(E) 3" CW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1" HW
(E) 1" CW
(E) 3/4" HW
(E) 1" CW
(E) 1" CW
(E) 3/4" HW
(E) 3/4" HWR
(E) 3/4" HWR
(E) 1 1/2" CW
(E) 1" HW
(E) 1" HW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1" HW
(E) 1 1/2" HW
(E) 3" CW
(E) 2 1/2" CW
(E) 3/4" HWR
(E) 1" HW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1" HW
(E) 1" HW
(E) 3/4" HW
(E) 2 1/2" CW
(E) 1 1/2" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 2 1/2" CW
(E) 2 1/2" CW
(E) 1 1/2" HW
(E) 3/4" HWR
(E) 2 1/2" CW
(E) 2 1/2" CW
(E) 3/4" HWR
(E) 2 1/2" HW
(E) 1 1/2" CW
(E) 1" HW
(E) 1 1/2" CW
(E) 1" HW
(E) 3/4" CW
(E) 1 1/2" CW
(E) 2 1/2" HW
(E) 1 1/2" CW
(E) 1" HW
(E) 2" CW
(E) 2" HW
(E) 3/4" CW
(E) 3/4" HW
(E) 2" HW
(E) 2" CW
(E) 1" HW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1" HW
(E) 1" HW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1" HW
(E) 1" HW
(E) 1 1/2" CW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:3 2:
A
M
PD-110
PARTIAL FIRST FLOOR PLAN #10 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
1/8" = 1'-0"1 01 Water - Segment A5
GENERAL NOTES
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DDBB
CCAA
Y Z A1 A2
A3 A4
W
O
K
G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
M
Q
I
A5
TRUE
NORTH
N
1. THIS AREA IS NEWLY CONSTRUCTED, CONTRACTOR TO VERIFY
EXISTING HOT/COLD WATER AND HOT WATER RETURN PIPING
HAS PROPER INSULATION. PROVIDE BID ALTERNATE TO ADD
INSUALTION IN THIS ARE AND PRICING FOR FIELD VERIFICATION.
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
40 6240 62
H
G
F
7 6 5 4 3 2 1
(E) 3/4" CW
(E) 3/4" HW
(E) 2" HW
(E) 3/4" CW
(E) 1 1/2" HW
(E) 3" CW
(E) 1 1/2" HW
(E) 3" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 1 1/2" CW
(E) 3" CW
(E) 3/4" CW
(E) 3" CW
(E) 3/4" CW
(E) 3" CW
(E) 1 1/2" HW
(E) 1 1/2" HW
(E) 1" HW
(E) 3/4" CW
(E) 3" CW
(E) 1 1/2" HW
(E) 3" CW
(E) 4" CW
(E) 1 1/2" HW
C W
H W
HW
CW
HW
C W
H W
C W
H W
C W
HW
CW
H
WC
W
(E) 6" CW
(E) 6" CW
C W
C W
C W
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" CW
(E) 1 1/4" CW(E) 1 1/4" CW
(E) 1 1/2" HW (E) 1 1/2" HW
(E) 3/4" HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 1 1/2" HW
(E) 1 1/2" HW
(E) 1 1/2" HW
(E) 1 1/2" HW
(E) 1 1/2" CW
(E) 1 1/2" CW
(E) 1 1/2" HW
(E) 1 1/2" HW(E) 1 1/2" CW
(E) 1 1/2" HW
(E) 3/4" CW
(E) 3/4" HW
CW
CW
C W
H W
C W
HW
CW
CWHW
CW
HW
HW
HW
H W
H W
C W
H W
C W
HW
(E) 2" CW
(E) 3" CW
(E) 3" CW
(E) 1 1/2" CW(E) 1 1/4" CW
(E) 1" CW
(E) 3" HWR
(E) 6" CW
(E) 5" HW(E) 2" HWR
CW
C W
C W
(E) 6" CW
(E) 6" CW(E) 12" CW
CW
(E) 2" CW
SHAFT
SH01-5
OFFICE
1D-08A
AC UNIT
1D-08
OFFICE
1D-05A
PLUMBING
1D-06
ELEV
EL01-A1
PAINT SHOP
1D-13
STORAGE
1D-12
PAINT SHOP
1D-11
STORAGE
1D-20
OP PLANT
C1-82
SUPV OFF
1D-16C
FIRE PUMP
1D-01B
PRI TOI
1D-16B
STAIR
ST01-9
BOILER RM
1D-16
OFFICE
1D-07
LOCKERS
1D-15
WELDING
1D-09
STRL UNIT
1D-05
ELEC
1D-04
OFFICE
1D-04A
MAINT
1D-14
ELEC
1D-03
MAINT
1D-02
ELEC
1D-09A
EQUIP RM
1D-01
BOOS PUMP
1D-18
GENERATOR
1D-19
CORR
C1-83
BOILERS/CHILLERS RM
1D-17
COMPACTOR
1D-10
EQUIP RM
1D-20A
CORR
C1-81
CORR
C1-80
GRAPH CTRL
1D-16A
(E) 3/4" CW
(E) 3/4" HW
CW
HW
(E) 3/4" HW
(E) 3/4" CW
(E) 3/4" CW
(E) 3/4" HW
(E) 2" HW
H W
(E) 3/4" CW
(E) 3/4" HW
(E) 3/4" HW
HW
(E) 2 1/2" CW
(E) 1 1/2" CW
(E) 3/4" HW
(E) 2" HW
HW
(E) 2" HW
(E)
(E) 3/4" HW
(E) 2" CW
(E) 6" CW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG. A1, SUITE 1218
ALHAMBRA CALIFORNIA 91803
3920 E. CORONADO STREET, SUITE 201
ANAHEIM CALIFORNIA 92807
ARCHITECTURE | INTERIORS | PROJECT MANAGEMENT
www.SRDArchitectsInc.com
O: 714 688 0212 | 626 202 0546 FAX: 714 688 0244
ARCHITECTS INC
Dwg. of
FINAL CONSTRUCTION DOCUMENTS
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
2100 East Route 66, Suite 210 Glendora, CA 91740 Tel: 626.650.0350 Fax: 626.650.0352 Job No. 2019-083-00
C :\U se rs
\rm ar tin ez
\D oc um en ts \V
AL
L
- L eg io ne lla S tu dy
Pl um bi ng _P bs en gi ne er s.
rv t
/1
7/
:3 2:
A
M
PD-111
PARTIAL FIRST FLOOR PLAN #11 RENOVATE DOMESTIC WATER PIPING
JERRY L. PETTIS MEMORIAL
605-20-201
12/10/2020
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
C.N. G.H.
1/8" = 1'-0"1 01 Water - Segment CC
SERVICE BAY 1
SERVICE BAY 3
SERVICE BAY 5
SERVICE BAY 7
SERVICE BAY 2
SERVICE BAY 4
SERVICE BAY 6
SERVICE BAY 8
DDBB
CCAA
Y Z A1 A2
A3 A4
W
O
K
G
S
C
V
N
J
F
R
B
X
T
D
H
L
P
U
A
E
M
Q
I
A5
TRUE
NORTH
N
GENERAL NOTES
DEMO KEY NOTES
POD - DEMO PIPE BACK TO MAIN. REMOVE ANY TEES AND/OR
ELBOWS TO PROVIDE PIPE WITH NO DEAD ENDS. (TYPICAL)
POD - EXISTING VALVE SHOWING SIGNS OF CORROSION.
DISCONNECT VALVE AND REPLACE WITH NEW VALVE.
(TYPICAL)
POD - DISCONNECT PIPE IN INTERSTITIAL SPACE AND PREPARE
FOR NEW CONNECTION. (TYPICAL)
EXISTING HOT, COLD WATER AND HOT WATER RETURN RISER.
1. WORK ON THIS FLOOR IN THIS AREA SHALL BE COORDINATED
WITH VA AND SHALL BE IN ACCORDANCE WITH THE PROPOSED
PHASING AS INDICATED ON THE PHASING NARRATIVE ON SHEET
P-001.
2. ALL FIXTURES SHALL BE VERIFIED WITH PLANS AND ASSOCIATED
PIPING.
3. CONTRACTOR TO FIELD VERIFY EXISTING INSULATION IS ON BOTH
HOT AND COLD WATER PIPING. CONTRACTOR TO VERIFY ITEMS
ARE INSTALLED CORRECTLY.
Revisions: Date:
35% SCHEMATIC DESIGN 02/16/2020
65% DESIGN SUBMITTAL 04/20/2020
100% CONSTRUCTION DOCUMENTS 08/05/2020
41 6241 62
STAFF TEAMING RM
2D-84
STAFF RESPITE AREA
2D-86
ON-CALL RM
2D-85
TOILET
2D-68A
TOILET
2D-66A
TOILET
2D-64A
TOILET
2D-62A
TOILET
2D-60A
TOILET
2D-58A
TOILET
2D-56A
TOILET
2D-54A
TOILET
2D-52A
TOILET
2D-50A
TOILET
2D-67A
TOILET
2D-65A
TOILET
2D-63A
TOILET
2D-61A
TOILET
2D-59A
TOILET BARIATRIC
2D-57A
SOILED UTILITY
2D-72
CLEAN UTILITY
2D-73
MEDICATION
2D-74
NOURISH
2D-80
STAFF TOILET
2D-82
STAFF TOILET
2D-81
EQUIPMENT STORAGE
2D-83
STAFF TL/SH
2D-85A
ICU 7
2D-68
ICU 8
2D-66
ICU 9
2D-64
ICU 10
2D-62
ICU 11
2D-60
ICU 12
2D-58
ICU 13
2D-56
ICU 14
2D-54
ICU 15
2D-52
ICU 16
2D-50
ICU 1 ISOLATION/ BARIATRIC
2D-57
ICU 2
2D-59
ICU 3
2D-61
ICU 4
2D-63
ICU 5
2D-65
ICU 6
2D-67
EQ ALC
C2-78A
EQ ALC
C2-79F
EQ ALC
C2-76D
CORR
C2-77
CORR
C2-78
CORR
C2-76
CORR
C2-79
CORR
C2-74
NURSE STATION
2D-78
PHYSICIAN
WORKROOM
2D-96
STRTCH/
EQUIP ALC
C2-78B C2-78C
PTS
2D-57E
N N
M M
C C
D D
E E
F F
G G
H H
J J
K K
L L
SERVBAY
SB02-1
SERVBAY
SB02-3
SERVBAY
SB02-2
SERVBAY
SB02-4
SERVBAY
SB02-6
SERVBAY
SB02-8
SERVBAY
SB02-7
SERVBAY
SB02-5
STAIR #1
ST02-1
CORRIDOR
2B-158
CORRIDOR
C-106**
CORRIDOR
C-105
CORRIDOR
C-107
CORR
C2-15
CORR
C2-14
CORR
C2-16
STAIR #2
ST02-2
CORR
C2-17
CORR
C2-13
CORR
C2-12
CORR
C2-27
ELEV
EL02-S1
ELEV
EL02-S2
ELEV
EL02-S3
STAIR #3
ST02-3
CORR
C2-42
CORR
C2-21
CORR
C2-50
CORR
C2-28
EQUIP RM
SB02-4A
CORR
C2-51
STAIR #5
ST02-5
ELEV LOB
C2-64
ELEV
EL02-S4
ELEV
EL02-S5
CORR
C2-63
CORR
C2-62
CORR
C2-66
EQUIP RM
SB02-6A
CORR
C2-61
CORR
C2-39
CORR
C2-38
CORR
C2-26
CORR
C2-49
COURT
CY02-4
CORR
C272
ELEV
EL02-S6
ELEV
EL02-S7
ELEV
EL02-S8
ELEV LOBBY
2D-03A
STAIR #6
ST02-6
CORR
C2-56
CORR
C2-53
EQUIP RM
SB02-7A
CORR
C2-67
COURT
CY02-3
EQUIP RM
SB02-8A
STAIR #8
ST02-8
MECH
MD-08
ELEC
MD-02
PD-201
PD-202
PD-203
PD-204
PD-205
PD-206
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
1000 S FREMONT AVE, UNIT 53,
BLDG.
This is the start of the file's text. The full file is on GovTribe.