REVISED_Attachment_C_-_Drawings.pdf
PDF 24 MB Posted
- Attached to
- BCGC – North Building Exterior Restoration
- Solicitation number
- B-2-26-25
- Issued by
- Brevard County, Florida
About this file
This revised architectural drawing set documents the exterior restoration project for the Brevard County Government Complex North Building, a six-story, 81,194 square-foot government facility located at 400 South Street, Titusville, Florida 32780. The project scope encompasses comprehensive restoration of all exterior wall and roof components exposed to weather, including curtain wall window wet sealing with structural silicone sealant replacement, precast concrete panel sealant restoration with double bead application and penetrating sealer, stucco wall crack repair and repainting, metal panel rust treatment and refinishing, hollow metal door restoration with stainless steel rain diverters, aluminum louver resealing, roof interface flashing and coping restoration, exterior soffit and ceiling repainting, column restoration, building signage removal and reinstallation, and expansion joint replacement. The base bid includes resecuring 25 unsecured curtain wall mullion covers and 50 linear feet of stucco crack repair, with six optional scope elements available for separate pricing: door assembly restoration, louver resealing, roofing interface sealing, soffit and ceiling refinishing, column restoration, and expansion joint replacement. The architectural drawings, prepared by Jay Ammon Architect, Inc. and dated September 24, 2025 with Addendum 1 dated April 3, 2026, include overall site plan, roof plan, north/south/east/west elevations, window details, wall sections, and exterior detail sheets. The pre-bid walk-through is scheduled for March 17, 2026, at 11:00 AM, with a questions deadline of March 27, 2026, and sealed bids due April 14, 2026, at 10:00 AM. Substantial completion is required within 150 calendar days from Notice to Proceed, with final completion within an additional 30 calendar days; liquidated damages are assessed at $500 per calendar day for delays.
The project requires contractors to demonstrate a minimum of ten years' experience in exterior building envelope restoration for similar-sized governmental facilities and provide three recent project examples with manufacturer pre-approval verification. All work must comply with the 2023 Florida Building Code and achieve UL 790 Class A fire rating, utilizing specified materials including Dowsil silicone sealants, Protectosil penetrating sealer, SOPREMA roof coating systems, and EMSEAL expansion joints. Required warranties include 20-year manufacturer warranties for roof coating with no dollar limit, 10-year warranties for joint sealants and paint systems, and 2-year installer warranties for correct installation and leakproof performance. The building will remain occupied and functional throughout construction; contractors must maintain watertight conditions daily and at shift end during inclement weather, protect all existing construction and landscaping, and return the site to original condition. Contractors must obtain a 5% bid bond with the proposal and, for projects exceeding $200,000, provide 100% public construction bonds and maintain $1,000,000 combined single limit general liability insurance and workers' compensation coverage. Progress payments follow Florida's Local Government Prompt Payment Act with 5% retainage retained until Final Completion. The contractor is responsible for all permits from authorities having jurisdiction except Brevard County, paying the initial $35 Brevard County permit application fee and all other applicable fees, while the County covers remaining Brevard County permit fees. No incumbent contractor is identified, and the specific contract award value is not disclosed in the solicitation documents.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET
NUMBER SHEET TITLE RELEASE
DATE
REVISION
NUMBER
REVISION
DATE
C1.0 COVER SHEET 09/24/2025 0 04/03/2026
A1.3 OVERALL SITE PLAN & AERIAL VIEWS
0 N/AA1.1 SYMBOLS, ABBREVIATIONS & CODE INFORMATION
0A1.2 SCOPE OF WORK & GENERAL NOTES
0 NA
A2.1 UPPER AND LOWER ROOF PLAN 0 04/03/2026
A3.1 0 04/03/2026
09/24/2025
09/24/2025
09/24/2025
09/24/2025
09/24/2025
09/24/2025
09/24/2025
09/24/2025
A3.2 SOUTH ELEVATION 0 04/03/202609/24/2025
EXTERIOR DETAILS
EXTERIOR DETAILS
EXTERIOR DETAILS
NORTH ELEVATION
A3.3 009/24/2025
A3.4 009/24/2025
SHEET
NUMBER SHEET TITLE RELEASE
DATE
REVISION
NUMBER
REVISION
DATE
SCALE: N.T.S.
VICINITY PLANN
TRUE NORTH
BREVARD GOVERNMENT COMPLEX NORTH
400 SOUTH STREET, TITUSVILLE,
FLORIDA 32780
DRAWING INDEX
SEPTEMBER 24, 2025
400 SOUTH STREET,
TITUSVILLE, FLORIDA 32780
PREPARED FOR:
ADDENDUM 1
BREVARD COUNTY
GOVERNMENT COMPLEX NORTH
EXTERIOR RESTORATION PROJECT
A4.1 WINDOW ELEVATION 0 04/03/202609/24/2025
EAST ELEVATION
A5.1
A5.2
09/24/2025
09/24/2025
PHOTOGRAPHS
A5.3
009/24/2025WEST ELEVATION
009/24/2025 EXTERIOR DETAILS
PHOTOGRAPHS
PHOTOGRAPHS
BOARD OF COUNTY COMMISSIONERS:
DISTRICT 1 - KATIE DELANEY
DISTRICT 2 - TOM GOODSON (VICE CHAIR)
DISTRICT 3 - KIM ADKINSON
DISTRICT 4 - ROB FELTNER (CHAIR)
DISTRICT 5 - THAD ALTMAN
ARCHITECT'S CODE COMPLIANCE
CERTIFICATION
JAY AMMON ARCHITECT, INC.
CERTIFIES THAT THESE
CONSTRUCTION DOCUMENTS
COMPLY WITH THE FLORIDA
BUILDING CODE - BUILDING,
2023 EDITION - 8TH EDITION
A5.4
009/24/2025 EXTERIOR DETAILSA5.5
A6.1
A6.2
A6.3
A4.2 WALL SECTIONS 0 04/03/202609/24/2025
0 N/A09/24/2025PROJECTED DURATION PLANA7.1
009/24/2025 EXTERIOR DETAILSA5.6
04/03/2026
04/03/2026
04/03/2026 04/03/2026
04/03/2026
04/03/2026
04/03/2026
04/03/2026
04/03/2026
04/03/2026
04/03/2026
04/03/2026
JAY AMMON ARCHITECT, INC.
126 SOUTH PARK AVE., SUITE A • WINTER PARK, FLORIDA 32789
PHONE: (407) 333-1977 • EMAIL: JAY@JAYAMMON.COM
WWW.JAYAMMON.COM
DESIGNED BY:DRAWN BY: APPROVED BY:
DATE: PROJECT NO.:
PHASE
PHASE
NO. DESCRIPTION DATE
REVISION
REV.
NO.
4 4
© 2025: ALL RIGHTS RESERVED. THESE DRAWINGS REMAIN THE PROPERTY OF JAY AMMON ARCHITECT, INC. AND ARE NOT TO BE USED IN ANY OTHER MANNER WITHOUT AGREEMENT IN WRITING BY JAY AMMON ARCHITECT, INC.
CONSULTANT:
CLIENT REF.:
DATE
TO THE BEST OF MY KNOWLEDGE, THESE
DRAWINGS COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODE REQUIREMENTS.
JAY AMMON AOR: AR0009798
SEAL: CLIENT: PROJECT: SHEET TITLE:
SHEET NO.:SCALE:
DESCRIPTION
1 2 3 4 5 6
6 6
7 7
1 2 3 4 5 6 7
A
B
C
D
A
B
C
D
NORTH BREVARD COUNTY GOVERNMENT COMPLEX
EXTERIOR RESTORATION PROJECT
400 SOUTH STREET, TITUSVILLE, FLORIDA 32780
BREVARD COUNTY PUBLIC WORKS
FACILITIES DEPARTMENT
2725 JUDGE FRAN JAMIESON WAY,
BUILDING A ROOM 207,
VIERA, FLORIDA 32940
CJS BTC JPA
05/24/2025 25-021
BID DOCUMENTS
60% DESIGN DOCUEMENTS 02/18/2025
90% DESIGN DOCUMENTS 03/18/2025
100% FINAL REVIEW DRAWINGS 04/18/2025
BID DOCUMENTS 09/24/2025
ADDENDUM 1 04/03/2026
COVER SHEET
C1.0
ARCHITECTURAL ABBREVIATIONS SYMBOLSMATERIALS LEGEND
CODE INFORMATION
APPLICABLE BUILDING CODES
TYPE I-A
YES - FULLY SPRINKLERED TO REMAIN
CLASSIFICATION: BUSINESS GROUP - B
6 (INCLUDING ROOF LEVEL)
78'-0" TO TOP OF PARAPET AND 91'-10" TO TOP OF (PENTHOUSE LEVEL)
TOTAL AREA - 81,194 SQ. FT.
STATEMENT OF COMPLIANCE
TO THE BEST OF OUR KNOWLEDGE THESE DRAWINGS ARE COMPLETE AND
COMPLY WITH THE FLORIDA BUILDING CODE 2023, AND REFERENCED
STATUTES, CODES, RULES AND REGULATIONS REFERENCED THEREIN.
JAY AMMON ARCHITECT, INC.
126 SOUTH PARK AVE., SUITE A • WINTER PARK, FLORIDA 32789
PHONE: (407) 333-1977 • EMAIL: JAY@JAYAMMON.COM
WWW.JAYAMMON.COM
DESIGNED BY:DRAWN BY: APPROVED BY:
DATE: PROJECT NO.:
PHASE
PHASE
NO. DESCRIPTION DATE
REVISION
REV.
NO.
4 4
© 2025: ALL RIGHTS RESERVED. THESE DRAWINGS REMAIN THE PROPERTY OF JAY AMMON ARCHITECT, INC. AND ARE NOT TO BE USED IN ANY OTHER MANNER WITHOUT AGREEMENT IN WRITING BY JAY AMMON ARCHITECT, INC.
CONSULTANT:
CLIENT REF.:
DATE
TO THE BEST OF MY KNOWLEDGE, THESE
DRAWINGS COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODE REQUIREMENTS.
JAY AMMON AOR: AR0009798
SEAL: CLIENT: PROJECT: SHEET TITLE:
SHEET NO.:SCALE:
DESCRIPTION
1 2 3 4 5 6
6 6
7 7
1 2 3 4 5 6 7
A
B
C
D
A
B
C
D
NORTH BREVARD COUNTY GOVERNMENT COMPLEX
EXTERIOR RESTORATION PROJECT
400 SOUTH STREET, TITUSVILLE, FLORIDA 32780
BREVARD COUNTY PUBLIC WORKS
FACILITIES DEPARTMENT
2725 JUDGE FRAN JAMIESON WAY,
BUILDING A ROOM 207,
VIERA, FLORIDA 32940
CJS BTC JPA
05/24/2025 25-021
BID DOCUMENTS
60% DESIGN DOCUEMENTS 02/18/2025
90% DESIGN DOCUMENTS 03/18/2025
100% FINAL REVIEW DRAWINGS 04/18/2025
BID DOCUMENTS 09/24/2025
ADDENDUM 1 04/03/2026
SYMBOLS, ABBREVIATIONS
AND CODE INFORMATION
A1.1
AutoCAD SHX Text
C.M.U. ( SECTION )
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
LETTER FOR DETAIL
AutoCAD SHX Text
NUMBER FOR SECTION
AutoCAD SHX Text
SHEET ON WHICH
AutoCAD SHX Text
SHEET ON WHICH ELEVATION OCCURS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
WALL SECTION
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
LETTERS FOR DETAILS
AutoCAD SHX Text
SHEET ON WHICH DETAIL OCCURS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
SECTION OCCURS
AutoCAD SHX Text
OVERALL BUILDING SECTION
AutoCAD SHX Text
SECTION OCCURS
AutoCAD SHX Text
SHEET ON WHICH
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text A
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text A3.1
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
NUMBERS FOR FLOOR, ENLARGED UNIT FLOOR PLANS & PHOTOS
AutoCAD SHX Text
EARTH
AutoCAD SHX Text
CONCRETE MASONRY
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
COMPRESSIBLE FILLER
AutoCAD SHX Text
PORTLAND CEMENT
AutoCAD SHX Text
PLASTER OVER METAL LATH
AutoCAD SHX Text
UNIT
AutoCAD SHX Text
PORTLAND
AutoCAD SHX Text
BATT INSULATION
AutoCAD SHX Text
ACOUSTICAL TILE
AutoCAD SHX Text
ACOUSTICAL INSULATION
AutoCAD SHX Text
MOTOR CONTROL CENTER
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
MODIFIED BITUMINOUS SHEET ROOFING
AutoCAD SHX Text
MAINTENANCE
AutoCAD SHX Text
HOSE BIBB
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
INSIDE DIAMETER
AutoCAD SHX Text
HORIZONTAL
AutoCAD SHX Text
HEATING VENTILATING & AIR CONDITIONING
AutoCAD SHX Text
KITCHEN EQUIPMENT CONTRACTOR
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MCC
AutoCAD SHX Text
MBSR
AutoCAD SHX Text
MATL
AutoCAD SHX Text
MAINT
AutoCAD SHX Text
KEC
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
INSUL
AutoCAD SHX Text
ID
AutoCAD SHX Text
HT
AutoCAD SHX Text
HB
AutoCAD SHX Text
HM
AutoCAD SHX Text
HORIZ
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
MEMBER
AutoCAD SHX Text
FINISH SYSTEM
AutoCAD SHX Text
PLYWOOD
AutoCAD SHX Text
WOOD BLOCKING
AutoCAD SHX Text
CONTINUOUS WOOD
AutoCAD SHX Text
FINISHED WOOD MEMBER
AutoCAD SHX Text
EXTERIOR INSULATION &
AutoCAD SHX Text
GLASS
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text
RIGID INSULATION
AutoCAD SHX Text
METAL
AutoCAD SHX Text
WATER RESISTANT
AutoCAD SHX Text
WORK POINT
AutoCAD SHX Text
WALL COVERING OR WATER CLOSET
AutoCAD SHX Text
WOOD
AutoCAD SHX Text
VINYL COMPOSITION TILE
AutoCAD SHX Text
UPHOLSTERY
AutoCAD SHX Text
TOP OF PARAPET
AutoCAD SHX Text
TOP OF WALL
AutoCAD SHX Text
UNLESS NOTED OTHERWISE
AutoCAD SHX Text
TOP OF STEEL
AutoCAD SHX Text
WD
AutoCAD SHX Text
WR
AutoCAD SHX Text
WP
AutoCAD SHX Text W/
AutoCAD SHX Text W/O
AutoCAD SHX Text
WC
AutoCAD SHX Text W
AutoCAD SHX Text
WITH
AutoCAD SHX Text
WIDE
AutoCAD SHX Text
WITHOUT
AutoCAD SHX Text
VCT
AutoCAD SHX Text
VERT
AutoCAD SHX Text
UPH
AutoCAD SHX Text
UNO
AutoCAD SHX Text
TYP
AutoCAD SHX Text
TOP
AutoCAD SHX Text
TOS
AutoCAD SHX Text
TOW
AutoCAD SHX Text
VERTICAL
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
CARPET
AutoCAD SHX Text
CPT
AutoCAD SHX Text
EXPOSED
AutoCAD SHX Text
EXP
AutoCAD SHX Text
GLASS FIBER REINFORCED CONCRETE
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
FIRE HOSE CABINET
AutoCAD SHX Text
FACE OF CONCRETE
AutoCAD SHX Text
FACE OF FINISH
AutoCAD SHX Text
FACE OF MASONRY
AutoCAD SHX Text
FACE OF STUD
AutoCAD SHX Text
FIBERGLASS REINFORCED PLASTIC
AutoCAD SHX Text FLOOR SINK or FINISH SEALER
AutoCAD SHX Text
GALVANIZED
AutoCAD SHX Text
GLASS FIBER REINFORCED GYPSUM
AutoCAD SHX Text
FOS
AutoCAD SHX Text
GA
AutoCAD SHX Text
GFRG
AutoCAD SHX Text H
AutoCAD SHX Text
GALV
AutoCAD SHX Text
GFRC
AutoCAD SHX Text
FT
AutoCAD SHX Text
FS
AutoCAD SHX Text
FRP
AutoCAD SHX Text
GAUGE
AutoCAD SHX Text
HIGH
AutoCAD SHX Text
FEET
AutoCAD SHX Text
FOF
AutoCAD SHX Text
FOC
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FIN
AutoCAD SHX Text
FLR
AutoCAD SHX Text
FHC
AutoCAD SHX Text
FBR
AutoCAD SHX Text
FD
AutoCAD SHX Text
FF
AutoCAD SHX Text
EXT
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
FABRIC
AutoCAD SHX Text
DISTRESSED WOOD PROCESS
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
DOWN SPOUT
AutoCAD SHX Text
DISTRESSED METAL PROCESS
AutoCAD SHX Text
ELECTRICAL DRINKING FOUNTAIN
AutoCAD SHX Text
DIAGONAL
AutoCAD SHX Text
EXTERIOR INSULATION & FINISH SYSTEM
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
ELECTRONIC EQUIPMENT ROOM
AutoCAD SHX Text
DS
AutoCAD SHX Text
EER
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
EQUIP
AutoCAD SHX Text
EQ
AutoCAD SHX Text
EIFS
AutoCAD SHX Text
EJ
AutoCAD SHX Text (E)
AutoCAD SHX Text
EA
AutoCAD SHX Text
EDF
AutoCAD SHX Text
EQUAL
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EACH
AutoCAD SHX Text
DMP
AutoCAD SHX Text
DWP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DIAG
AutoCAD SHX Text
DET
AutoCAD SHX Text
DIA
AutoCAD SHX Text
DBL
AutoCAD SHX Text D
AutoCAD SHX Text
CT
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
DEPTH
AutoCAD SHX Text
DOUBLE
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
CONCRETE MASONRY UNIT
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text AREA DRAIN or AREA DEVELOPMENT
AutoCAD SHX Text ACOUSTICAL CEILING TILE or ACOUSTICAL TREATMENT
AutoCAD SHX Text
AIR CONDITIONING
AutoCAD SHX Text
CONTROL JOINT
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
CLG
AutoCAD SHX Text
COL
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CONT
AutoCAD SHX Text
CMU
AutoCAD SHX Text
CLR
AutoCAD SHX Text
CJ
AutoCAD SHX Text
BLDG
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CLEAR
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
AFF
AutoCAD SHX Text
AD
AutoCAD SHX Text
ACT
AutoCAD SHX Text A/C
AutoCAD SHX Text
OWNER FURNISHED ITEM
AutoCAD SHX Text
OFI
AutoCAD SHX Text
REF
AutoCAD SHX Text
REFERENCE
AutoCAD SHX Text
SANITARY SHEET PLASTIC
AutoCAD SHX Text
TOP OF MASONRY
AutoCAD SHX Text
SURFACED FOUR SIDES
AutoCAD SHX Text
SPECIAL FINISH
AutoCAD SHX Text
RESILIENT FLOOR
AutoCAD SHX Text SQUARE FEET or STONE FACE
AutoCAD SHX Text
ROUGH OPENING
AutoCAD SHX Text
SOLID CORE
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
SUSPENDED
AutoCAD SHX Text
TONGUE AND GROOVE
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text TOP OF CONCRETE or CURB
AutoCAD SHX Text
SQUARE
AutoCAD SHX Text
SQ
AutoCAD SHX Text T&G
AutoCAD SHX Text
TOM
AutoCAD SHX Text
TOC
AutoCAD SHX Text
TEL
AutoCAD SHX Text T
AutoCAD SHX Text
STD
AutoCAD SHX Text S4S
AutoCAD SHX Text
SUSP
AutoCAD SHX Text
SSP
AutoCAD SHX Text
SS
AutoCAD SHX Text
TREAD
AutoCAD SHX Text
SPF
AutoCAD SHX Text
SIM
AutoCAD SHX Text
SF
AutoCAD SHX Text
SHT
AutoCAD SHX Text
SC
AutoCAD SHX Text
RO
AutoCAD SHX Text
REQD
AutoCAD SHX Text
RM
AutoCAD SHX Text
RF
AutoCAD SHX Text
SIMILAR
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
RESILIENT BASE STRAIGHT
AutoCAD SHX Text
REFLECTED CEILING PLAN
AutoCAD SHX Text
RESILIENT BASE COVE
AutoCAD SHX Text
POINT OF SALE
AutoCAD SHX Text
OWNER FURNISHED CONTRACTOR INSTALLED
AutoCAD SHX Text
OWNER FURNISHED OWNER INSTALLED
AutoCAD SHX Text
POINT OF CONNECTION
AutoCAD SHX Text
PLASTIC LAMINATE
AutoCAD SHX Text
PREPARATION
AutoCAD SHX Text
QUARRY TILE
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
PREP
AutoCAD SHX Text R or RAD
AutoCAD SHX Text R
AutoCAD SHX Text
RBS
AutoCAD SHX Text
RCP
AutoCAD SHX Text
RD
AutoCAD SHX Text
RBC
AutoCAD SHX Text
QT
AutoCAD SHX Text
RISER
AutoCAD SHX Text
RADIUS
AutoCAD SHX Text
POC
AutoCAD SHX Text
POS
AutoCAD SHX Text
PR
AutoCAD SHX Text
PLYWD
AutoCAD SHX Text
PNT
AutoCAD SHX Text
PLAM
AutoCAD SHX Text
PL
AutoCAD SHX Text
OFOI
AutoCAD SHX Text
OFCI
AutoCAD SHX Text
OPP
AutoCAD SHX Text
PLYWOOD
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAIR
AutoCAD SHX Text
PLATE
AutoCAD SHX Text
OPPOSITE
AutoCAD SHX Text
OPERATOR CONTROL PANEL
AutoCAD SHX Text
OPERATOR CONTROL CONSOLE
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MEZZANINE
AutoCAD SHX Text
MOISTURE RESISTANT TREATMENT
AutoCAD SHX Text
MISCELLANEOUS
AutoCAD SHX Text
NOT RATED
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text OUTSIDE DIAMETER or OVERFLOW DRAIN
AutoCAD SHX Text
ON CENTER
AutoCAD SHX Text
MRT
AutoCAD SHX Text
OCC
AutoCAD SHX Text
OCP
AutoCAD SHX Text
OD
AutoCAD SHX Text
OC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NR
AutoCAD SHX Text
MIN
AutoCAD SHX Text
MFR
AutoCAD SHX Text
MISC
AutoCAD SHX Text
MECH
AutoCAD SHX Text
MEZZ
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
CEMENT PLASTER
AutoCAD SHX Text
WDF
AutoCAD SHX Text
WOOD FLOOR
AutoCAD SHX Text
STONE
AutoCAD SHX Text
ST
AutoCAD SHX Text
METAL
AutoCAD SHX Text
MET
AutoCAD SHX Text
BRICK FACE
AutoCAD SHX Text
BF
AutoCAD SHX Text
METAL FACE
AutoCAD SHX Text
MF
AutoCAD SHX Text
PF
AutoCAD SHX Text
PLASTER FACE
AutoCAD SHX Text
WOOD FACE
AutoCAD SHX Text
WF
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
EL
AutoCAD SHX Text
MASONRY OPENING
AutoCAD SHX Text
MO
AutoCAD SHX Text
ACRYLIC RESIN FLOORING
AutoCAD SHX Text
ARF
AutoCAD SHX Text
BOARD
AutoCAD SHX Text
BD
AutoCAD SHX Text
BO
AutoCAD SHX Text
BOTTOM OF
AutoCAD SHX Text
BOH
AutoCAD SHX Text
BACK OF HOUSE
AutoCAD SHX Text
BOT
AutoCAD SHX Text
BOTTOM
AutoCAD SHX Text
CONTRACTOR FURNISHED OWNER INSTALLED
AutoCAD SHX Text
CFOI
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
DWG
AutoCAD SHX Text
DRAWER
AutoCAD SHX Text
DWR
AutoCAD SHX Text
EYEHOOK
AutoCAD SHX Text
EH
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
FDN
AutoCAD SHX Text
FINISH FLOOR ELEVATION
AutoCAD SHX Text
FFE
AutoCAD SHX Text
GLASS
AutoCAD SHX Text
GL
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text
GYP BD
AutoCAD SHX Text
HIGH POINT
AutoCAD SHX Text
HP
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
INT
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
JT
AutoCAD SHX Text
JOINT
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
LAV
AutoCAD SHX Text
LIVE LOAD
AutoCAD SHX Text
LL
AutoCAD SHX Text
NEW
AutoCAD SHX Text (N)
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NTS
AutoCAD SHX Text
PROJECTION
AutoCAD SHX Text
PROJ
AutoCAD SHX Text
POUNDS PER SQUARE FPPT
AutoCAD SHX Text
PSF
AutoCAD SHX Text
REINFORCED CONCRETE
AutoCAD SHX Text
RC
AutoCAD SHX Text
ROUGH SAWN
AutoCAD SHX Text
RS
AutoCAD SHX Text
STEEL
AutoCAD SHX Text
STL
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
STRUCT
AutoCAD SHX Text
VIF
AutoCAD SHX Text
VERIFY IN FIELD
AutoCAD SHX Text
WOOD BASE
AutoCAD SHX Text
WDB
AutoCAD SHX Text
APPROX
AutoCAD SHX Text
APPROXIMATELY
AutoCAD SHX Text
AIR HANDLING UNIT
AutoCAD SHX Text
AHU
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
CO
AutoCAD SHX Text
DEAD LOAD
AutoCAD SHX Text
DL
AutoCAD SHX Text
FMG
AutoCAD SHX Text
FACTORY MUTUAL GLOBAL
AutoCAD SHX Text
FRT
AutoCAD SHX Text
FIRE RETARDANT TREATED
AutoCAD SHX Text
NATIONAL ROOFING CONTRACTORS ASSOCIATION
AutoCAD SHX Text
NRCA
AutoCAD SHX Text P.S.I.
AutoCAD SHX Text
POUNDS PER SQUARE INCH
AutoCAD SHX Text
PRESSURE TREATED
AutoCAD SHX Text
PT
AutoCAD SHX Text
SQUARE FEET OR SQUARE FOOT
AutoCAD SHX Text
SQ FT
AutoCAD SHX Text
SOUTHERN YELLOW PINE
AutoCAD SHX Text
SYP
AutoCAD SHX Text
GALLON
AutoCAD SHX Text
GAL
AutoCAD SHX Text
HOUR
AutoCAD SHX Text
HR
AutoCAD SHX Text
KILN DRIED AFTER TREATMENT
AutoCAD SHX Text
KDAT
AutoCAD SHX Text
LOW POINT
AutoCAD SHX Text
LP
AutoCAD SHX Text
UL
AutoCAD SHX Text
UNDERWRITERS LABORATORIES INC.
AutoCAD SHX Text
KD
AutoCAD SHX Text
KILN DRIED
AutoCAD SHX Text
DENS DECK SHEATHING
AutoCAD SHX Text
2023 FLORIDA BUILDING CODE - BUILDING
AutoCAD SHX Text
BUILDING :
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text
2023 FLORIDA BUILDING CODE - EXISTING BUILDING
AutoCAD SHX Text
EXISTING :
AutoCAD SHX Text
2023 FLORIDA BUILDING CODE - MECHANICAL
AutoCAD SHX Text
MECHANICAL :
AutoCAD SHX Text
2023 FLORIDA BUILDING CODE - PLUMBING
AutoCAD SHX Text
PLUMBING :
AutoCAD SHX Text
2023 FLORIDA BUILDING CODE - FUEL GAS
AutoCAD SHX Text
FUEL GAS :
AutoCAD SHX Text
2023 FLORIDA BUILDING CODE - ACCESSIBILITY
AutoCAD SHX Text
ACCESSIBILITY :
AutoCAD SHX Text
2023 FLORIDA BUILDING CODE - ENERGY CONSERVATION
AutoCAD SHX Text
ENERGY :
AutoCAD SHX Text
FLORIDA FIRE PREVENTION CODE (2023)
AutoCAD SHX Text
FIRE :
AutoCAD SHX Text
CONSTRUCTION TYPE: TYPE I-A
AutoCAD SHX Text
FIRE SPRINKLERS: YES - FULLY SPRINKLERED TO REMAIN
AutoCAD SHX Text
OCCUPANCY: CLASSIFICATION: BUSINESS GROUP - B
AutoCAD SHX Text
STORIES: 6 (INCLUDING ROOF LEVEL)
AutoCAD SHX Text BUILDING HEIGHT: 78'-0" TO TOP OF PARAPET AND 91'-10" TO TOP OF (PENTHOUSE LEVEL)
AutoCAD SHX Text
PROJECT AREA: TOTAL AREA - 81,194 SQ. FT.
AutoCAD SHX Text
DETAIL/WALL SECTION CROSS REFERENCE
AutoCAD SHX Text
EIGHTH
AutoCAD SHX Text
EIGHTH
AutoCAD SHX Text
EIGHTH
AutoCAD SHX Text
EIGHTH
AutoCAD SHX Text
EIGHTH
AutoCAD SHX Text
EIGHTH
AutoCAD SHX Text
EIGHTH
AutoCAD SHX Text
EIGHTH
GENERAL NOTES:
A. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD. THIS SHALL
INCLUDE VERIFYING THE EXACT LOCATIONS, DIMENSIONS AND QUANTITIES OF ALL WALL
MOUNTED EQUIPMENT AND PENETRATIONS WHICH INCLUDES, BUT IS NOT LIMITED TO
VENT PIPES, DRAINS, ELECTRICAL JUNCTION BOXES, CURBS, FLASHING AND ALL OTHERS
PENETRATIONS AND WORK ASSOCIATED WITH THIS EXTERIOR FACADE RESTORATION
PROJECT. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT, IN WRITING, OF ALL EXISTING
CONDITIONS WHICH ARE IN VARIANCE WITH THE CONDITIONS DOCUMENTED HEREIN.
B. THE BUILDING MAY BE FULLY OR PARTIALLY OCCUPIED; CONTRACTOR IS SOLELY
RESPONSIBLE FOR ALL MEANS AND METHODS OF CONSTRUCTION AND FOR THE SAFETY
OF ALL PERSONS AT THE PROJECT SITE.
C. CONTRACTOR SHALL PROTECT ALL EXISTING CONSTRUCTION TO REMAIN, INCLUDING
ADJACENT ROOFS, WALLS, GROUNDS, EXTERIOR SURFACES AND THE INTERIOR OF THE
BUILDING. THIS SHALL INCLUDE, BUT IS NOT LIMITED TO PAINT, WATER, DUST, DEBRIS AND
PHYSICAL DAMAGE. ALL SURFACES SHALL BE RESTORED TO THEIR PRE-DAMAGE
CONDITION BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER AND TO THE
SATISFACTION OF THE OWNER AND ARCHITECT.
D. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL CODES AND
AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT.
E. ALL DETAILS INDICATE MINIMUM INSTALLATION REQUIREMENTS. IF THE
MANUFACTURER'S STANDARDS DETAILS ARE MORE STRINGENT, IN THE OPINION OF THE
ARCHITECT, THEY SHALL GOVERN. IF THE DETAILS SHOWN ARE MORE STRINGENT THAN
THE MANUFACTURER'S STANDARD DETAILS, IN THE OPINION OF THE ARCHITECT, THE
DETAILS SHOWN SHALL GOVERN, REGARDLESS OF THE MANUFACTURER'S WILLINGNESS
TO WARRANT / GUARANTY THE LESSER DETAIL. BY SUBMITTING A BID FOR THIS PROJECT,
IT IS UNDERSTOOD THAT THE CONTRACTOR AND MANUFACTURER AGREE TO WARRANT /
GUARANTY THE DETAILS SHOWN. THE ARCHITECT MAY, BUT IS NOT OBLIGATED TO,
ACCEPT ANY PROPOSED CHANGES TO THE DETAILS SHOWN.
F. THE CONTRACTOR IS TO PROVIDE ALL LABOR AND MATERIAL FOR A COMPLETE AND
WATERTIGHT JOB WHICH IS FULLY WARRANTED / GUARANTEED BY THE MANUFACTURER
AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. ANY DETAILS OR WORK REQUIRED FOR
A COMPLETE JOB, BUT NOT SHOWN OR SPECIFIED BY THE CONTRACT DOCUMENTS,
SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS
AND REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. ANY ADDITIONAL LABOR
AND MATERIAL REQUIRED TO MEET MANUFACTURER'S WARRANTY / GUARANTY
REQUIREMENTS, BUT NOT INDICATED BY THE CONTRACT DOCUMENTS, SHALL BE
PROVIDED AT NO ADDITIONAL COST TO THE OWNER.
G. ALL REFINISHING REQUIREMENTS, SHALL INCLUDE THE FOLLOWING:
REMOVE ALL RUST FROM METAL SURFACES AND APPLY COAT OF RUST INHIBITOR.
REPLACE ALL METAL COMPONENTS WHICH ARE CORRODED THROUGH THE METAL.
PRESSURE CLEAN ALL EXPOSED SURFACES. SECURE ALL LOOSE COMPONENTS WITH
STAINLESS STEEL FASTENERS WHICH EXTEND INTO SOLID SUBSTRATE BELOW OR BEHIND
COMPONENT BEING SECURED. CONCEAL FASTENER HEADS WITH MATERIAL WHICH
MATCHES ADJACENT SURFACES. REPAINT ALL EXPOSED SURFACES TO MATCH EXISTING
FINISHES.
H. LAYDOWN/STORAGE AREA IS LIMITED AND SHALL BE AS APPROVED BY THE OWNER.
I. PRIOR TO PERFORMING WORK, CONTRACTOR SHALL INSPECT WORK SITE AND EXISTING
CONSTRUCTION FOR POTENTIAL SAFETY HAZARDS. PROVIDE FOR THE SAFETY AND
PROTECTION OF WORKERS AND OCCUPANTS THROUGHOUT COURSE OF WORK. COMPLY
WITH OSHA REQUIREMENTS.
J. BUILDING ACCESS IS RESTRICTED AND ALLOWED ONLY AS REQUIRED TO ACCOMPLISH
CONTRACT WORK. COORDINATE ANY REQUIRED ACCESS WITH THE OWNER.
K. SITE SHALL BE CLEANED AND SECURED ON A DAILY BASIS AND "SHOW READY" AT THE
END OF EACH WORK SHIFT.
L. ALL COMPONENTS AND ASSEMBLIES SHALL MEET OR EXCEED UL 790 STANDARDS FOR
A CLASS A FIRE RATING.
M. THE FINISH OF ALL NEW COMPONENTS OR REPAIRED COMPONENTS SHALL MATCH
ALL CHARACTERISTICS OF THE EXISTING COMPONENTS INCLUDING TEXTURE AND ALL
OTHER QUALITIES.
N. PATCH ALL FINISHES AFFECTED BY THE WORK OF THIS PROJECT AS REQUIRED TO
MATCH ALL CHARACTERISTICS OF EXISTING UNDAMAGED FINISHES.
BUILDING PROTECTION NOTES:
A. THE BUILDING WILL REMAIN FUNCTIONAL THROUGHOUT THE CONSTRUCTION PERIOD.
CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO CONTENTS AND
OCCUPANTS.
B. THE BUILDING SHALL BE WATERTIGHT AT THE END OF EACH DAYS CONSTRUCTION
AND WHEN INCLEMENT WEATHER THREATENS.
C. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT THE
BUILDING, EXTERIOR AND GROUNDS, INCLUDING GRASS, PLANTS, TREES, SHRUBS, OTHER
LANDSCAPING, AND ALL PROMENADE CONCRETE WITHIN THE PROJECT BOUNDARIES.
D. ANY SURFACES STAINED, MARKED, MARRED, OR DAMAGED BY THE CONTRACTOR
SHALL BE RETURNED TO ORIGINAL CONDITION AND TO MATCH ADJACENT SURFACES.
E. THE CONTRACTOR SHALL RETURN THE SITE AND ANY DAMAGED ITEMS OF THE SITE OR
FACILITY TO THEIR ORIGINAL CONDITION.
F. THE SEQUENCE OF WORK SHALL MINIMIZE CONSTRUCTION TRAFFIC ON THE NEW
WORK.
EXTERIOR RESTORATION NOTES:
A. FOR PURPOSES OF THIS PROJECT, REMOVE SHALL MEAN REMOVE AND DISPOSE OF IN
AN APPROVED AND LEGAL MANNER.
B. CONTRACTOR SHALL VERIFY THE TOTAL NUMBER OF DETAIL CONDITIONS IN THE FIELD
AND PERFORM NEW WORK IN ACCORDANCE WITH THE DETAIL REFERENCED OR THOSE
WHICH ARE SIMILAR. CONTRACTOR SHALL VERIFY ALL CONDITIONS IN THE FIELD.
C. GENERAL DEMOLITION SCOPE: REMOVE ALL DESIGNATED DETERIORATED WALL
COMPONENTS REQUIRED FOR THE EXTERIOR RESTORATION PROJECT.
D. PROVIDE AND INSTALL TEMPORARY ROOFING, NIGHT SEALS, AND FLASHING AS
REQUIRED TO PROTECT EXISTING BUILDING INTERIOR FROM DAMAGE.
E. CONTRACTOR SHALL REMOVE ALL DEBRIS FROM CONSTRUCTION SITE AND DISPOSE
OF IN A LEGAL MANNER.
F. DAMAGED OR DETERIORATED SUBSTRATE UNCOVERED DURING DEMOLITION SHALL
BE DOCUMENTED BY THE CONTRACTOR, REPORTED TO THE OWNER IN WRITING.
G. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING ROOF AND WALL
MATERIALS AND METHODS OF INSTALLATION BEFORE THE START OF WORK. ANY
DISCREPANCIES BETWEEN THE INFORMATION PROVIDED BY THE CONTRACT DOCUMENTS
AND CONDITIONS ENCOUNTERED BY THE CONTRACTOR BEFORE THE START OF WORK
SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER. THE CONTRACTOR
SHALL NOT BE ENTITLED TO COMPENSATION FOR ANY ADDITIONAL LABOR OR MATERIALS
DUE TO DIFFERING EXISTING CONDITIONS WHICH ARE NOT BROUGHT TO THE ATTENTION
OF THE OWNER PRIOR TO THE START OF WORK.
H. THE CONTRACTOR SHALL REMOVE ALL EXISTING EXTERIOR CONDUIT, PIPING, LIGHTING
FIXTURES, LIGHTNING PROTECTION SYSTEMS, FACADE PENETRATION AND ANY OTHER
ITEMS WHICH INTERFERE WITH THE EXTERIOR FACADE RESTORATION AND RELATED
WORK. ALL SUCH EQUIPMENT AND ITEMS SHALL BE TEMPORARILY RE-ROUTED AS
NECESSARY IF IT IS REQUIRED TO STAY IN SERVICE. ANY ITEMS NOT REQUIRED TO STAY IN
SERVICE SHALL BE PROPERLY STORED BY THE CONTRACTOR AND REINSTALLED AT THE
COMPLETION OF THE WORK. ALL WORK SHALL BE PERFORMED BY QUALIFIED, LICENSED
CRAFTSMAN IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES AT NO ADDITIONAL
COST TO THE OWNER. ANY EXISTING WORK WHICH DOES NOT CONFORM TO APPLICABLE
CURRENT CODES SHALL BE REPORTED TO THE OWNER IN WRITING PRIOR TO THE
REMOVAL. INSTALL NEW OR EXISTING LIGHTNING PROTECTION COMPONENTS BY
QUALIFIED, LICENSED LIGHTNING PROTECTION INSTALLER WITH MINIMUM 5 YEARS
EXPERIENCE IN THE INSTALLATION OF LIGHTNING PROTECTION SYSTEMS IN ACCORDANCE
WITH NFPA-780 AND ALL APPLICABLE BUILDING CODES.
I. ALL EXISTING OVERFLOW SCUPPERS AND DRAIN LINES SHALL BE CHECKED BY THE
CONTRACTOR PRIOR TO THE START OF WORK. ANY DRAIN LINES FOUND TO BE CLOGGED
OR RESTRICTED SHALL BE REPORTED TO THE OWNER IN WRITING BEFORE PROCEEDING
WITH THE WORK. ANY DRAIN LINES FOUND TO BE CLOGGED OR RESTRICTED AFTER THE
START OF WORK, WHICH WERE NOT REPORTED AS SUCH PRIOR TO THE START OF WORK,
SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
ALL ROOF DRAINS AND OVERFLOW SCUPPERS MUST BE KEPT OPEN AND FULLY
FUNCTIONING DURING THE ENTIRE CONSTRUCTION PERIOD, WITH ANY CLOGS TO BE
CLEANED OUT PROMPTLY.
J. ALL DEPICTED COMPONENTS ON DRAWINGS ARE NEW UNLESS IDENTIFIED AS EXISTING.
JAY AMMON ARCHITECT, INC.
126 SOUTH PARK AVE., SUITE A • WINTER PARK, FLORIDA 32789
PHONE: (407) 333-1977 • EMAIL: JAY@JAYAMMON.COM
WWW.JAYAMMON.COM
DESIGNED BY:DRAWN BY: APPROVED BY:
DATE: PROJECT NO.:
PHASE
PHASE
NO. DESCRIPTION DATE
REVISION
REV.
NO.
4 4
© 2025: ALL RIGHTS RESERVED. THESE DRAWINGS REMAIN THE PROPERTY OF JAY AMMON ARCHITECT, INC. AND ARE NOT TO BE USED IN ANY OTHER MANNER WITHOUT AGREEMENT IN WRITING BY JAY AMMON ARCHITECT, INC.
CONSULTANT:
CLIENT REF.:
DATE
TO THE BEST OF MY KNOWLEDGE, THESE
DRAWINGS COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODE REQUIREMENTS.
JAY AMMON AOR: AR0009798
SEAL: CLIENT: PROJECT: SHEET TITLE:
SHEET NO.:SCALE:
DESCRIPTION
1 2 3 4 5 6
6 6
7 7
1 2 3 4 5 6 7
A
B
C
D
A
B
C
D
NORTH BREVARD COUNTY GOVERNMENT COMPLEX
EXTERIOR RESTORATION PROJECT
400 SOUTH STREET, TITUSVILLE, FLORIDA 32780
BREVARD COUNTY PUBLIC WORKS
FACILITIES DEPARTMENT
2725 JUDGE FRAN JAMIESON WAY,
BUILDING A ROOM 207,
VIERA, FLORIDA 32940
CJS BTC JPA
05/24/2025 25-021
BID DOCUMENTS
60% DESIGN DOCUEMENTS 02/18/2025
90% DESIGN DOCUMENTS 03/18/2025
100% FINAL REVIEW DRAWINGS 04/18/2025
BID DOCUMENTS 09/24/2025
ADDENDUM 1 04/03/2026
SCOPE OF WORK & GENERAL NOTES
A1.2
SCOPE OF WORK:
0.1. GENERAL: THE EXTERIOR RESTORATION OF THE BREVARD COUNTY
GOVERNMENT COMPLEX NORTH BUILDING INCLUDES THE RESTORATION OF ALL
EXTERIOR WALL AND DESIGNATED ROOFING COMPONENTS EXPOSED TO THE WEATHER.
AT A MINIMUM, ALL EXTERIOR ENVELOPE CURTAIN WALL COMPONENTS WILL BE REPAIRED,
RESEALED AND PAINTED. ALL EXPOSED SEALANTS WHICH INTERFACE WITH THE CURTAIN
WALL ASSEMBLY WILL BE REPLACED. WHERE A SCOPE OF WORK ITEM IS DESIGNATED,
THAT DESIGNATION IS TYPICAL FOR ALL SIMILAR COMPONENTS AND ASSEMBLIES
WHETHER OR NOT SPECIFICALLY DENOTED/CALLED OUT IN THE DRAWINGS. SEE PROJECT
MANUAL AND BID FORMS FOR BASE BID AND OPTION PRICING ON THE FOLLOWING SCOPE
OF WORK ITEMS.
1.0 EXTERIOR WINDOWS:
1.1 CURTAIN WALL WINDOWS AND INTEGRAL PANELS "WET SEALING":
REMOVE ALL PREVIOUSLY APPLIED SEALANTS FROM THE CURTAIN WALL WINDOWS AND
INTEGRAL METAL PANELS. INSPECT ALL VERTICAL MULLIONS, INSTALL NEW STAINLESS
STEEL FASTENERS WITH EPDM WASHERS TO SECURE VERTICAL MULLION COVERS TO
EXSITING CURTAIN WALL SUB-FRAMING. INSPECT ALL HORIZONTAL MULLION COVERS
AND INCLUDED WITH THE BASE BID OF RESECURING 25 UNSECURED MULLION COVERS
PRIOR TO NEW SEALANT APPLICATION. INSTALL CLOSED CELL BACKER ROD AND
SILICONE SEALANT AT ALL METAL FRAME TO PRECAST CONCRETE, METAL TO METAL AND
METAL TO GLASS JOINTS. REMOVE ALL CORROSION DEPOSITS FROM INTEGRAL METAL
PANEL SURFACES AND INSTALL AN EPOXY BASED RUST INHIBITOR PRIMER TO ALL
PREVIOUSLY CORRODED SURFACES. PRIME ALL METAL PANEL SURFACES AND APPLY
TWO COATS OF HIGH PERFORMANCE DTM PAINT TO ALL CURTAIN WALL VERTICAL AND
HORIZONTAL MULLION COVERS, CURTAIN WALL FRAMES, COLUMN COVERS, SILL PANS,
TRIM AND INTEGRAL METAL PANEL SURFACES. SEE SHEETS A4.1 AND A4.2. SEE
SPECIFICATION SECTIONS 07 92 00 AND 09 99 00.
1.2 ALUMINUM STOREFRONT WINDOWS AND STOREFRONT ENTRANCES "WET
SEALING": REMOVE ALL PREVIOUSLY APPLIED "WET SEAL" SEALANTS FROM THE EXISTING
STOREFRONT WINDOW AND DOOR FRAMES AND GLASS. INSTALL NEW CLOSED CELL
BACKER ROD AND DOWSIL 795 SILICONE SEALANT AT ALL METAL FRAME TO PRECAST
CONCRETE, METAL TO METAL, AND METAL TO GLASS JOINTS. SEE SHEETS A4.3. SEE
SPECIFICATION SECTION 07 92 00.
1.3 CURTAIN WALL AND STOREFRONT WINDOWS MOCKUP AND TESTING:
PRIOR TO THE FULL WINDOW RESTORATION, PREPARE IN-FIELD MOCKUPS OF EACH
WINDOW TYPE FOR THE OWNER'S AND ARCHITECTS REVIEW. WITH A REPRESENTATIVE OF
THE ARCHITECT PRESENT, CONDUCT THIRD PARTY INDEPENDENT WATER TESTING USING
THE AAMA 501.2 (NEWEST VERSION) TEST PROCEDURES. AT ANY FAILURES, REPAIR THE
MOCKUP AND CONTINUE TO RETEST UNTIL THE MOCKUPS PASS THE TEST. AT EACH TEST
AREA, REPAIR ALL AFFECTED INTERIOR AND EXTERIOR WALL FINISHES. DO NOT PROCEED
WITH THE RESTORATION OF THE OTHER WINDOWS UNTIL RECEIVING NOTIFICATION FROM
THE ARCHITECT. ALL THIRD PARTY TESTING WILL BE PROVIDED BY THE
OWNER/ARCHITECT. CONTRACTOR IS TO PROVIDE TESTING ACCESS TO MOCKUPS.
2.0 EXTERIOR WALL RESTORATION:
2.1 PRECAST CONCRETE PANELS:
2.1A PRECAST CONCRETE VENEER WALL SEALANT REPLACEMENT: REMOVE
ALL HORIZONTAL AND VERTICAL SEALANTS ASSOCIATED WITH THE PRECAST CONCRETE
PANEL SURFACES, INCLUDING OVERHEAD SOFFITS. INSTALL NEW PRIMARY AND
SECONDARY SEALANT JOINTS. INSTALL A CLOSED CELL BACKER ROD AT ALL VERTICAL
AND HORIZONTAL JOINTS. PRIME WALL JOINT SUBSTRATES, AND APPLY NEW SECONDARY
DOWSIL 795 SILICONE SEALANT AT ALL HORIZONTAL AND VERTICAL JOINTS. PROVIDE
ADDITIONAL BOND BREAKER AND APPLY A SECOND LAYER OF DOWSIL 795 SILICONE
SEALANT TO CREATE A "DOUBLE SEALANT" JOINT PROFILE. SEE SPECIFICATION 07 92 00.
2.1A PRECAST CONCRETE WALL FABRICATION: POWER WASH ALL PRECAST
CONCRETE WALL SURFACES. APPLY PROTECTOSIL CHEMTRETE BSM 400 CLEAR
PENETRATING SEALER TO ALL PRECAST CONCRETE WALL SURFACES. SEE SPECIFICATION
SECTION 07 19 00.
2.1B SEALANT REPLACEMENT: REMOVE ALL SEALANTS ASSOCIATED WITH THE WALL
PENETRATIONS AND WALL MOUNTED EQUIPMENT, INSTALL BACKER ROD AND DOWSIL 795
SILICONE SEALANT AT ALL JOINTS PENETRATING THROUGH THE PRECAST CONCRETE
WALL PANELS. SEE SPECIFICATION SECTION 07 92 00.
2.2 STUCCO WALL AND SOFFIT ASSEMBLY:
2.2A EXISTING STUCCO RESTORATION: ROUTE OUT ALL CRACKED STUCCO
SURFACES. PATCH STUCCO WITH NEW TEXTURED URETHANE SEALANT. PRESSURE
CLEAN ALL WALL AND SOFFIT SURFACES AND APPLY PRIMER AND HIGH PERFORMANCE
ACRYLIC COATING SYSTEM TO ALL STUCCO WALL SURFACES. REPLACE ALL SEALANTS
ASSOCIATED WITH THIS WALL ASSEMBLY. APPLY URETHANE SEALANT AT ALL VERTICAL
AND HORIZONTAL STUCCO CONTROL JOINTS AND STUCCO REVEALS MAINTAINING
PROFILES OF EXISTING JOINTS AND REVEALS. INCLUDE 50 LINEAR FEET OF STUCCO
CRACK REPAIR WITHIN BASE BID. SEE SPECIFICATION SECTIONS 07 92 00 AND 09 99 00.
2.3 METAL WALL PANELS: AT EXISTING METAL WALL PANELS, REMOVE AND REPLACE
EXISTING PERIMETER SEALANT WITH DOW 795. AT RUSTED LOCATIONS, SCRAPE ALL RUST
/ DETERIORATION TO SOLID METAL. PATCH PANEL WITH METAL PATCHING FILLER (BONDO
BY 3M OR APPROVED EQUAL). PRESSURE WASH EXISTING PANELS AND REMOVE ALL
LOOSE OR DELAMINATED FINISHES. PREP, PRIME AND PAINT TOP SURFACE OF METAL.
APPLY ONE LAYER OF PRIMER AND TWO COATS OF HIGH PERFORMANCE DTM FINISH
COAT. SEE SPECIFICATION SECTION 09 90 00.
2.4 WALL MOUNTED LIGHTS: TEMPORARILY REMOVE AND LOG CONDITION OF EACH
WALL MOUNTED LIGHT FIXTURE. SEAL ALL CONDUIT PENETRATIONS. REINSTALL EXISTING
LIGHT FIXTURES AND TEST FOR OPERATION AFTER EXTERIOR WALL WATERPROOFING
APPLICATION. ALL ELECTRICAL WORK TO BE COMPLETED BY A STATE OF FLORIDA
LICENSED ELECTRICIAN. SEE SPECIFICATION SECTION 07 92 00.
2.5 SCUPPERS SEALING: REMOVE ALL EXISTING EXTERIOR SEALANTS FROM THE
EXISTING METAL SCUPPER FLASHINGS. INSTALL BACKER ROD AND SEALANT AT ALL
EXTERIOR JOINTS. PREPARE EXISTING ROOF MEMBRANE PER ROOF MANUFACTURES
REQUIREMENT INCLUDING THE REMOVAL OF ANY EXISTING DELAMINATED ROOF
MEMBRANE (SOPREMA). PRIME ALL EXISTING ROOF MEMBRANE AND SCUPPER INSERT
SURFACES, AND INSTALL SOPREMA REINFORCED LIQUID ALSAN RS 230 PMMA COATING
SYSTEM (COLOR WHITE) OVER SOPREMA APPROVED PRIMER. MAINTAIN ALL EXISTING
SOPREMA ROOF SYSTEM WARRANTIES.
2.6 FOUNDATION WALLS: REMOVE ALL EXISTING EXTERIOR SEALANTS AND
UNADHERED PAINT FROM EXISTING FOUNDATIONS WALLS. REPLACE ANY SEALANTS
ASSOCIATED WITH THE FOUNDATION WALLS. PRIME AND PAINT ALL FOUNDATION WALL
SURFACES. TEST, PREPARE, PRIME AND PAINT ALL PREVIOUSLY PAINTED MASONRY
SURFACES PER OWNER COLOR SELECTIONS AND LOCATIONS. APPLY ONE LAYER OF
3.1 HOLLOW METAL DOOR RESTORATION & THRESHOLD RESEALING: REMOVE
ALL SEALANTS FROM THE EXISTING DOOR COMPONENTS. PROPERLY PREPARE ALL
SURFACES AND INSTALL NEW BOND BREAKERS AND SEALANTS AT PERIMETER DOOR
FRAME JOINTS. INSTALL TRAFFIC RATED SEALANTS AT THE INTERFACE OF THE EXISTING
DOOR THRESHOLD AND DOOR JAMB FRAMING. TREAT ANY CORRODED METAL SURFACES,
PRIME AND PAINT ALL DOOR FRAME AND DOOR LEAF SURFACES WITH A HIGH
PERFORMANCE DTM METAL COATING SYSTEM. INSTALL 18 GAUGE TYPE 316 STAINLESS
STEEL RAIN DIVERTER FLASHING OVER DOOR ASSEMBLIES. SEE SPECIFICATION SECTION
07 92 00.
3.2 DIVERTER INSTALLATION AT ROOF ACCESS DOORS: INSTALL NEW 18 GAUGE
TYPE 316 STAINLESS STEEL DIVERTER OVER PAINTED HOLLOW METAL ROOF ACCESS
DOOR ASSEMBLY. SET VERTICAL FLANGE OF DIVERTER IN SEALANT TAPE AND SECURE TO
THE EXISTING PRECAST CONCRETE WALL ASSEMBLY.
3.3 ROLL-UP DOOR RESEALING AND PAINTING: REMOVE ALL SEALANTS FROM THE
EXISTING DOOR COMPONENTS. PROPERLY PREPARE ALL SURFACES AND INSTALL NEW
BOND BREAKERS AND SEALANTS AT PERIMETER DOOR FRAME JOINTS. TREAT ANY
CORRODED METAL SURFACES, PRIME AND PAINT ALL DOOR FRAME AND DOOR LEAF
SURFACES WITH A HIGH PERFORMANCE DTM METAL COATING SYSTEM.
4.0 ALUMINUM FRAMED LOUVER ASSEMBLY:
4.1 LOUVER REFINISHING: REMOVE EXISTING SEALANTS FROM THE INTERFACE OF
THE LOUVER FRAMES AND ADJACENT STUCCO OR OTHER BUILDING ENVELOPE
COMPONENTS. INSTALL NEW BACKER ROD AND URETHANE SEALANT. PRIME AND PAINT
ALL PREVIOUSLY PAINTED LOUVER FRAME SURFACES. MILL FINISHED ALUMINUM
SURFACES TO REMAIN. SEE SPECIFICATION SECTION 07 92 00.
5.0 ROOF INTERFACES:
5.1 METAL COPINGS: REMOVE ALL EXPOSED SEALANTS AT THE PARAPET COPINGS.
PRIME METAL AND/OR ADJACENT BUILDING ENVELOPE SURFACES AND INSTALL DOWSIL
123 SEALANT TAPE SYSTEM. INSTALL MOCK-UPS FOR OWNER REVIEW. SEE
SPECIFICATION SECTION 07 92 00.
5.2 COUNTERFLASHING: REMOVE ALL EXPOSED SEALANTS AT THE EXISTING
COUNTERFLASHINGS SEALANT TRAYS. INSTALL NEW DOWSIL 795 SEALANTS OVER PRIMED
PRECAST CONCRETE AND SHEET METAL SURFACES. AT METAL JOINTS INSTALL DOWSILL
123 TAPE AT JOINTS. PROVIDE TAPE TO MATCH PROPOSED METAL PANELS COLOR
(BRONZE).
5.3 THROUGH-WALL SECONDARY SCUPPERS: REPLACE ALL SEALANTS
ASSOCIATED WITH THE EXISTING SCUPPER FLASHINGS AND TRIM. INSTALL A FULLY
REINFORCED COATING BY ROOF MEMBRANE MANUFACTURER AT THE INTERFACE OF THE
SCUPPER AND ROOF SYSTEM.
6.0 EXTERIOR SOFFITS, CEILINGS AND ROOF OVERHANGS:
6.1 EXTERIOR SOFFITS, CEILINGS AND ROOF OVERHANGS REFINISHING:
PRESSURE CLEAN ALL EXTERIOR FASCIA, SOFFITS, EXTERIOR CEILINGS AND ROOF
OVERHANG SURFACES. APPLY PRIMER AND TWO LAYERS OF TOP COAT TO ALL
PREVIOUSLY PAINTED SURFACES. SEE SPECIFICATION SECTION 09 99 00.
7.0 COLUMN RESTORATION:
7.1 COLUMN RESTORATION: AT EXISTING COLUMNS, PRESSURE WASH WALL AT
SURFACES. PREP, PRIME AND PAINT. APPLY TWO LAYERS OF TOP COAT. INSTALL NEW
BACKER ROD AND TRAFFIC RATED SEALANT AT ALL COLUMN TO HARDSCAPE INTERFACES.
SEE SPECIFICATION SECTION 07 92 00.
8.0 BUILDING SIGNAGE:
8.1 EXISTING SIGNAGE: TEMPORARILY REMOVE EXISTING BUILDING SIGNAGE AND
DELIVER TO OWNER DESIGNATED LOCATION FOR STORAGE. REINSTALL EXISTING
SIGNAGE AFTER THE WATERPROOFING OF THE EXTERIOR WALL SURFACES. SECURE
SIGNAGE WITH STAINLESS STEEL BRACKETS AND FASTENERS WITH EPDM WASHERS. SEAL
ALL FENESTRATIONS.
9.0 EXPANSION JOINTS:
9.1 EXPANSION JOINT REPLACEMENT: LOCATIONS OF THE EXPANSION JOINTS
ARE LOCATED BETWEEN PRECAST CONCRETE PANELS AND CURTAIN WALL ASSEMBLIES.
PRE-MANUFACTURED EXPANSION JOINTS (E.G., EMSEAL COLORSEAL) ARE NOT REQUIRED.
EXPANSION JOINTS SHALL BE TREATED WITH A DOUBLE SEALANT BEAD APPLICATION IN
ACCORDANCE WITH DETAIL D/A5.2 ON DRAWING SET A5.2.
LEGEND
SEE ENLARGED ROOF PLANS ON
SHEET A2.1
CONSTRUCTION NOTES:
1. CONSTRUCTION LIMITS: LIMITS ARE WITHIN 10 FEET MAXIMUM OF BUILDINGS
EXCEPT WHERE OTHERWISE INDICATED BY OWNER.
2. CONSTRUCTION STAGING AREA: COORDINATE IN THE FIELD WITH
REPRESENTATIVE FROM THE OWNER FOR STAGING AREA LOCATION.
3. ACCESSIBLE PATH: THE ACCESSIBLE PATH MUST BE LEFT UNIMPEDED
THROUGHOUT THE CONSTRUCTION. PROVIDE BARRIERS BETWEEN THE
CONSTRUCTION AND THE ACCESSIBLE PATH AS NECESSARY TO PROVIDE SAFE
ACCESS.
4. SAFETY PLAN: CONTRACTOR TO SUBMIT SAFETY PLAN WHICH CLEARLY
DELINEATES AREAS FOR CONSTRUCTION, SAFETY BARRIERS, EXITS, CONSTRUCTION
TRAFFIC DURING VARIOUS PHASES OF THE PROJECT AND WHEN CONDITIONS
CHANGE. CONTRACTOR TO CONFORM WITH REQUIREMENTS IN FBC-B, FFPC 1-16.1
AND NFPA 241.
BUILDING INCLUDED IN
SCOPE OF WORK
SCALE:
OVERALL SITE PLAN1
A1.3 NTS. N TR
U
E
SCALE:
AERIAL VIEW 2
A1.3 NTS.
SCALE:
SOUTH SIDE 3
A1.3 NTS.
N
TRUE
N
TR
U
E
JAY AMMON ARCHITECT, INC.
126 SOUTH PARK AVE., SUITE A • WINTER PARK, FLORIDA 32789
PHONE: (407) 333-1977 • EMAIL: JAY@JAYAMMON.COM
WWW.JAYAMMON.COM
DESIGNED BY:DRAWN BY: APPROVED BY:
DATE: PROJECT NO.:
PHASE
PHASE
NO. DESCRIPTION DATE
REVISION
REV.
NO.
4 4
© 2025: ALL RIGHTS RESERVED. THESE DRAWINGS REMAIN THE PROPERTY OF JAY AMMON ARCHITECT, INC. AND ARE NOT TO BE USED IN ANY OTHER MANNER WITHOUT AGREEMENT IN WRITING BY JAY AMMON ARCHITECT, INC.
CONSULTANT:
CLIENT REF.:
DATE
TO THE BEST OF MY KNOWLEDGE, THESE
DRAWINGS COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODE REQUIREMENTS.
JAY AMMON AOR: AR0009798
SEAL: CLIENT: PROJECT: SHEET TITLE:
SHEET NO.:SCALE:
DESCRIPTION
1 2 3 4 5 6
6 6
7 7
1 2 3 4 5 6 7
A
B
C
D
A
B
C
D
NORTH BREVARD COUNTY GOVERNMENT COMPLEX
EXTERIOR RESTORATION PROJECT
400 SOUTH STREET, TITUSVILLE, FLORIDA 32780
BREVARD COUNTY PUBLIC WORKS
FACILITIES DEPARTMENT
2725 JUDGE FRAN JAMIESON WAY,
BUILDING A ROOM 207,
VIERA, FLORIDA 32940
CJS BTC JPA
05/24/2025 25-021
BID DOCUMENTS
60% DESIGN DOCUEMENTS 02/18/2025
90% DESIGN DOCUMENTS 03/18/2025
100% FINAL REVIEW DRAWINGS 04/18/2025
BID DOCUMENTS 09/24/2025
ADDENDUM 1 04/03/2026
AS SHOWN
SCALE PERTAINS TO A 24" X 36" SHEET
OVERALL SITE PLAN AND AERIAL
VIEWS
A1.3
BUILDING ELEVATION DESIGNATIONS
X
AX.X
WALL SECTIONS DESIGNATIONS
LEGEND
DESCRIPTIONSYMBOL
5.1
EXISTING MAIN ROOF PARAPET WALL
WITH METAL COPINGS
NOT IN CONTRACT
SCOPE OF WORK DESIGNATION NOTES
EXISTING LOWER ROOF PARAPET CURBS
EXISTING ROOF SCUPPER
(SEE SCOPE OF WORK 2.5)
EXISTING LOW SLOPE ROOF
N.I.C.
X
ROOF LADDER
FIRST FLOOR NORTH ROOF
EXISTING ROOF VENTS
ROOF DESIGNATIONS
JAY AMMON ARCHITECT, INC.
126 SOUTH PARK AVE., SUITE A • WINTER PARK, FLORIDA 32789
PHONE: (407) 333-1977 • EMAIL: JAY@JAYAMMON.COM
WWW.JAYAMMON.COM
DESIGNED BY:DRAWN BY: APPROVED BY:
DATE: PROJECT NO.:
PHASE
PHASE
NO. DESCRIPTION DATE
REVISION
REV.
NO.
4 4
© 2025: ALL RIGHTS RESERVED. THESE DRAWINGS REMAIN THE PROPERTY OF JAY AMMON ARCHITECT, INC. AND ARE NOT TO BE USED IN ANY OTHER MANNER WITHOUT AGREEMENT IN WRITING BY JAY AMMON ARCHITECT, INC.
CONSULTANT:
CLIENT REF.:
DATE
TO THE BEST OF MY KNOWLEDGE, THESE
DRAWINGS COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODE REQUIREMENTS.
JAY AMMON AOR: AR0009798
SEAL: CLIENT: PROJECT: SHEET TITLE:
SHEET NO.:SCALE:
DESCRIPTION
1 2 3 4 5 6
6 6
7 7
1 2 3 4 5 6 7
A
B
C
D
A
B
C
D
NORTH BREVARD COUNTY GOVERNMENT COMPLEX
EXTERIOR RESTORATION PROJECT
400 SOUTH STREET, TITUSVILLE, FLORIDA 32780
BREVARD COUNTY PUBLIC WORKS
FACILITIES DEPARTMENT
2725 JUDGE FRAN JAMIESON WAY,
BUILDING A ROOM 207,
VIERA, FLORIDA 32940
CJS BTC JPA
05/24/2025 25-021
BID DOCUMENTS
60% DESIGN DOCUEMENTS 02/18/2025
90% DESIGN DOCUMENTS 03/18/2025
100% FINAL REVIEW DRAWINGS 04/18/2025
BID DOCUMENTS 09/24/2025
ADDENDUM 1 04/03/2026
24'8' 16'4'0'
3/32" = 1'-0"
SCALE PERTAINS TO A 24" X 36" SHEET
UPPER AND LOWER ROOF PLAN
A2.1
SCALE:
ROOF PLAN1
A2.1 3/32" = 1'-0"
A3.3
A3.2
A3.1
A3.4
N TR
U
E
0.1. GENERAL: THE EXTERIOR RESTORATION OF THE BREVARD COUNTY
GOVERNMENT COMPLEX NORTH BUILDING INCLUDES THE RESTORATION OF ALL
EXTERIOR WALL AND DESIGNATED ROOFING COMPONENTS EXPOSED TO THE WEATHER.
AT A MINIMUM, ALL EXTERIOR ENVELOPE CURTAIN WALL COMPONENTS WILL BE REPAIRED,
RESEALED AND PAINTED. ALL EXPOSED SEALANTS WHICH INTERFACE WITH THE CURTAIN
WALL ASSEMBLY WILL BE REPLACED. WHERE A SCOPE OF WORK ITEM IS DESIGNATED,
THAT DESIGNATION IS TYPICAL FOR ALL SIMILAR COMPONENTS AND ASSEMBLIES
WHETHER OR NOT SPECIFICALLY DENOTED/CALLED OUT IN THE DRAWINGS. SEE PROJECT
MANUAL AND BID FORMS FOR BASE BID AND OPTION PRICING ON THE FOLLOWING SCOPE
OF WORK ITEMS.
1.0 EXTERIOR WINDOWS:
1.1 CURTAIN WALL WINDOWS AND INTEGRAL PANELS "WET SEALING":
REMOVE ALL PREVIOUSLY APPLIED SEALANTS FROM THE CURTAIN WALL WINDOWS AND
INTEGRAL METAL PANELS. INSPECT ALL VERTICAL MULLIONS, INSTALL NEW STAINLESS
STEEL FASTENERS WITH EPDM WASHERS TO SECURE VERTICAL MULLION COVERS TO
EXSITING CURTAIN WALL SUB-FRAMING. INSPECT ALL HORIZONTAL MULLION COVERS
AND INCLUDED WITH THE BASE BID OF RESECURING 25 UNSECURED MULLION COVERS
PRIOR TO NEW SEALANT APPLICATION. INSTALL CLOSED CELL BACKER ROD AND
SILICONE SEALANT AT ALL METAL FRAME TO PRECAST CONCRETE, METAL TO METAL AND
METAL TO GLASS JOINTS. REMOVE ALL CORROSION DEPOSITS FROM INTEGRAL METAL
PANEL SURFACES AND INSTALL AN EPOXY BASED RUST INHIBITOR PRIMER TO ALL
PREVIOUSLY CORRODED SURFACES. PRIME ALL METAL PANEL SURFACES AND APPLY
TWO COATS OF HIGH PERFORMANCE DTM PAINT TO ALL CURTAIN WALL VERTICAL AND
HORIZONTAL MULLION COVERS, CURTAIN WALL FRAMES, COLUMN COVERS, SILL PANS,
TRIM AND INTEGRAL METAL PANEL SURFACES. SEE SHEETS A4.1 AND A4.2. SEE
SPECIFICATION SECTIONS 07 92 00 AND 09 99 00.
1.2 ALUMINUM STOREFRONT WINDOWS AND STOREFRONT ENTRANCES "WET
SEALING": REMOVE ALL PREVIOUSLY APPLIED "WET SEAL" SEALANTS FROM THE EXISTING
STOREFRONT WINDOW AND DOOR FRAMES AND GLASS. INSTALL NEW CLOSED CELL
BACKER ROD AND DOWSIL 795 SILICONE SEALANT AT ALL METAL FRAME TO PRECAST
CONCRETE, METAL TO METAL, AND METAL TO GLASS JOINTS. SEE SHEETS A4.3. SEE
SPECIFICATION SECTION 07 92 00.
1.3 CURTAIN WALL AND STOREFRONT WINDOWS MOCKUP AND TESTING:
PRIOR TO THE FULL WINDOW RESTORATION, PREPARE IN-FIELD MOCKUPS OF EACH
WINDOW TYPE FOR THE OWNER'S AND ARCHITECTS REVIEW. WITH A REPRESENTATIVE OF
THE ARCHITECT PRESENT, CONDUCT THIRD PARTY INDEPENDENT WATER TESTING USING
THE AAMA 501.2 (NEWEST VERSION) TEST PROCEDURES. AT ANY FAILURES, REPAIR THE
MOCKUP AND CONTINUE TO RETEST UNTIL THE MOCKUPS PASS THE TEST. AT EACH TEST
AREA, REPAIR ALL AFFECTED INTERIOR AND EXTERIOR WALL FINISHES. DO NOT PROCEED
WITH THE RESTORATION OF THE OTHER WINDOWS UNTIL RECEIVING NOTIFICATION FROM
THE ARCHITECT. ALL THIRD PARTY TESTING WILL BE PROVIDED BY THE
OWNER/ARCHITECT. CONTRACTOR IS TO PROVIDE TESTING ACCESS TO MOCKUPS.
2.0 EXTERIOR WALL RESTORATION:
2.1 PRECAST CONCRETE PANELS:
2.1A PRECAST CONCRETE VENEER WALL SEALANT REPLACEMENT: REMOVE
ALL HORIZONTAL AND VERTICAL SEALANTS ASSOCIATED WITH THE PRECAST CONCRETE
PANEL SURFACES, INCLUDING OVERHEAD SOFFITS. INSTALL NEW PRIMARY AND
SECONDARY SEALANT JOINTS. INSTALL A CLOSED CELL BACKER ROD AT ALL VERTICAL
AND HORIZONTAL JOINTS. PRIME WALL JOINT SUBSTRATES, AND APPLY NEW SECONDARY
DOWSIL 795 SILICONE SEALANT AT ALL HORIZONTAL AND VERTICAL JOINTS. PROVIDE
ADDITIONAL BOND BREAKER AND APPLY A SECOND LAYER OF DOWSIL 795 SILICONE
SEALANT TO CREATE A "DOUBLE SEALANT" JOINT PROFILE. SEE SPECIFICATION 07 92 00.
2.1A PRECAST CONCRETE WALL FABRICATION: POWER WASH ALL PRECAST
CONCRETE WALL SURFACES. APPLY PROTECTOSIL CHEMTRETE BSM 400 CLEAR
PENETRATING SEALER TO ALL PRECAST CONCRETE WALL SURFACES. SEE SPECIFICATION
SECTION 07 19 00.
2.1B SEALANT REPLACEMENT: REMOVE ALL SEALANTS ASSOCIATED WITH THE WALL
PENETRATIONS AND WALL MOUNTED EQUIPMENT, INSTALL BACKER ROD AND DOWSIL 795
SILICONE SEALANT AT ALL JOINTS PENETRATING THROUGH THE PRECAST CONCRETE
WALL PANELS. SEE SPECIFICATION SECTION 07 92 00.
2.2 STUCCO WALL AND SOFFIT ASSEMBLY:
2.2A EXISTING STUCCO RESTORATION: ROUTE OUT ALL CRACKED STUCCO
SURFACES. PATCH STUCCO WITH NEW TEXTURED URETHANE SEALANT. PRESSURE
CLEAN ALL WALL AND SOFFIT SURFACES AND APPLY PRIMER AND HIGH PERFORMANCE
ACRYLIC COATING SYSTEM TO ALL STUCCO WALL SURFACES. REPLACE ALL SEALANTS
ASSOCIATED WITH THIS WALL ASSEMBLY. APPLY URETHANE SEALANT AT ALL VERTICAL
AND HORIZONTAL STUCCO CONTROL JOINTS AND STUCCO REVEALS MAINTAINING
PROFILES OF EXISTING JOINTS AND REVEALS. INCLUDE 50 LINEAR FEET OF STUCCO
CRACK REPAIR WITHIN BASE BID. SEE SPECIFICATION SECTIONS 07 92 00 AND 09 99 00.
2.3 METAL WALL PANELS: AT EXISTING METAL WALL PANELS, REMOVE AND REPLACE
EXISTING PERIMETER SEALANT WITH DOW 795. AT RUSTED LOCATIONS, SCRAPE ALL RUST
/ DETERIORATION TO SOLID METAL. PATCH PANEL WITH METAL PATCHING FILLER (BONDO
BY 3M OR APPROVED EQUAL). PRESSURE WASH EXISTING PANELS AND REMOVE ALL
LOOSE OR DELAMINATED FINISHES. PREP, PRIME AND PAINT TOP SURFACE OF METAL.
APPLY ONE LAYER OF PRIMER AND TWO COATS OF HIGH PERFORMANCE DTM FINISH
COAT. SEE SPECIFICATION SECTION 09 90 00.
2.4 WALL MOUNTED LIGHTS: TEMPORARILY REMOVE AND LOG CONDITION OF EACH
WALL MOUNTED LIGHT FIXTURE. SEAL ALL CONDUIT PENETRATIONS. REINSTALL EXISTING
LIGHT FIXTURES AND TEST FOR OPERATION AFTER EXTERIOR WALL WATERPROOFING
APPLICATION. ALL ELECTRICAL WORK TO BE COMPLETED BY A STATE OF FLORIDA
LICENSED ELECTRICIAN. SEE SPECIFICATION SECTION 07 92 00.
2.5 SCUPPERS SEALING: REMOVE ALL EXISTING EXTERIOR SEALANTS FROM THE
EXISTING METAL SCUPPER FLASHINGS. INSTALL BACKER ROD AND SEALANT AT ALL
EXTERIOR JOINTS. PREPARE EXISTING ROOF MEMBRANE PER ROOF MANUFACTURES
REQUIREMENT INCLUDING THE REMOVAL OF ANY EXISTING DELAMINATED ROOF
MEMBRANE (SOPREMA). PRIME ALL EXISTING ROOF MEMBRANE AND SCUPPER INSERT
SURFACES, AND INSTALL SOPREMA REINFORCED LIQUID ALSAN RS 230 PMMA COATING
SYSTEM (COLOR WHITE) OVER SOPREMA APPROVED PRIMER. MAINTAIN ALL EXISTING
SOPREMA ROOF SYSTEM WARRANTIES.
2.6 FOUNDATION WALLS: REMOVE ALL EXISTING EXTERIOR SEALANTS AND
UNADHERED PAINT FROM EXISTING FOUNDATIONS WALLS. REPLACE ANY SEALANTS
ASSOCIATED WITH THE FOUNDATION WALLS. PRIME AND PAINT ALL FOUNDATION WALL
SURFACES. TEST, PREPARE, PRIME AND PAINT ALL PREVIOUSLY PAINTED MASONRY
SURFACES PER OWNER COLOR SELECTIONS AND LOCATIONS. APPLY ONE LAYER OF
APPROVED PRIMER + TWO LAYERS OF TOP COAT. SEE SPECIFICATION SECTION 09 90 00.
3.0 PAINTED HOLLOW METAL DOORS:
3.1 HOLLOW METAL DOOR RESTORATION & THRESHOLD RESEALING: REMOVE
ALL SEALANTS FROM THE EXISTING DOOR COMPONENTS. PROPERLY PREPARE ALL
SURFACES AND INSTALL NEW BOND BREAKERS AND SEALANTS AT PERIMETER DOOR
FRAME JOINTS. INSTALL TRAFFIC RATED SEALANTS AT THE INTERFACE OF THE EXISTING
DOOR THRESHOLD AND DOOR JAMB FRAMING. TREAT ANY CORRODED METAL SURFACES,
PRIME AND PAINT ALL DOOR FRAME AND DOOR LEAF SURFACES WITH A HIGH
PERFORMANCE DTM METAL COATING SYSTEM. INSTALL 18 GAUGE TYPE 316 STAINLESS
STEEL RAIN DIVERTER FLASHING OVER DOOR ASSEMBLIES. SEE SPECIFICATION SECTION
07 92 00.
3.2 DIVERTER INSTALLATION AT ROOF ACCESS DOORS: INSTALL NEW 18 GAUGE
TYPE 316 STAINLESS STEEL DIVERTER OVER PAINTED HOLLOW METAL ROOF ACCESS
DOOR ASSEMBLY. SET VERTICAL FLANGE OF DIVERTER IN SEALANT TAPE AND SECURE TO
THE EXISTING PRECAST CONCRETE WALL ASSEMBLY.
3.3 ROLL-UP DOOR RESEALING AND PAINTING: REMOVE ALL SEALANTS FROM THE
EXISTING DOOR COMPONENTS. PROPERLY PREPARE ALL SURFACES AND INSTALL NEW
BOND BREAKERS AND SEALANTS AT PERIMETER DOOR FRAME JOINTS. TREAT ANY
CORRODED METAL SURFACES, PRIME AND PAINT ALL DOOR FRAME AND DOOR LEAF
SURFACES WITH A HIGH PERFORMANCE DTM METAL COATING SYSTEM.
4.0 ALUMINUM FRAMED LOUVER ASSEMBLY:
4.1 LOUVER REFINISHING: REMOVE EXISTING SEALANTS FROM THE INTERFACE OF
THE LOUVER FRAMES AND ADJACENT STUCCO OR OTHER BUILDING ENVELOPE
COMPONENTS. INSTALL NEW BACKER ROD AND URETHANE SEALANT. PRIME AND PAINT
ALL PREVIOUSLY PAINTED LOUVER FRAME SURFACES. MILL FINISHED ALUMINUM
SURFACES TO REMAIN. SEE SPECIFICATION SECTION 07 92 00.
5.0 ROOF INTERFACES:
5.1 METAL COPINGS: REMOVE ALL EXPOSED SEALANTS AT THE PARAPET COPINGS.
PRIME METAL AND/OR ADJACENT BUILDING ENVELOPE SURFACES AND INSTALL DOWSIL
123 SEALANT TAPE SYSTEM. INSTALL MOCK-UPS FOR OWNER REVIEW. SEE
SPECIFICATION SECTION 07 92 00.
5.2 COUNTERFLASHING: REMOVE ALL EXPOSED SEALANTS AT THE EXISTING
COUNTERFLASHINGS SEALANT TRAYS. INSTALL NEW DOWSIL 795 SEALANTS OVER PRIMED
PRECAST CONCRETE AND SHEET METAL SURFACES. AT METAL JOINTS INSTALL DOWSILL
123 TAPE AT JOINTS. PROVIDE TAPE TO MATCH PROPOSED METAL PANELS COLOR
(BRONZE).
5.3 THROUGH-WALL SECONDARY SCUPPERS: REPLACE ALL SEALANTS
ASSOCIATED WITH THE EXISTING SCUPPER FLASHINGS AND TRIM. INSTALL A FULLY
REINFORCED COATING BY ROOF MEMBRANE MANUFACTURER AT THE INTERFACE OF THE
SCUPPER AND ROOF SYSTEM.
6.0 EXTERIOR SOFFITS, CEILINGS AND ROOF OVERHANGS:
6.1 EXTERIOR SOFFITS, CEILINGS AND ROOF OVERHANGS REFINISHING:
PRESSURE CLEAN ALL EXTERIOR FASCIA, SOFFITS, EXTERIOR CEILINGS AND ROOF
OVERHANG SURFACES. APPLY PRIMER AND TWO LAYERS OF TOP COAT TO ALL
PREVIOUSLY PAINTED SURFACES. SEE SPECIFICATION SECTION 09 99 00.
7.0 COLUMN RESTORATION:
7.1 COLUMN RESTORATION: AT EXISTING COLUMNS, PRESSURE WASH WALL AT
SURFACES. PREP, PRIME AND PAINT. APPLY TWO LAYERS OF TOP COAT. INSTALL NEW
BACKER ROD AND TRAFFIC RATED SEALANT AT ALL COLUMN TO HARDSCAPE INTERFACES.
SEE SPECIFICATION SECTION 07 92 00.
8.0 BUILDING SIGNAGE:
8.1 EXISTING SIGNAGE: TEMPORARILY REMOVE EXISTING BUILDING SIGNAGE AND
DELIVER TO OWNER DESIGNATED LOCATION FOR STORAGE. REINSTALL EXISTING
SIGNAGE AFTER THE WATERPROOFING OF THE EXTERIOR WALL SURFACES. SECURE
SIGNAGE WITH STAINLESS STEEL BRACKETS AND FASTENERS WITH EPDM WASHERS. SEAL
ALL FENESTRATIONS.
9.0 EXPANSION JOINTS:
9.1 EXPANSION JOINT REPLACEMENT: LOCATIONS OF THE EXPANSION JOINTS
ARE LOCATED BETWEEN PRECAST CONCRETE PANELS AND CURTAIN WALL ASSEMBLIES.
PRE-MANUFACTURED EXPANSION JOINTS (E.G., EMSEAL COLORSEAL) ARE NOT REQUIRED.
EXPANSION JOINTS SHALL BE TREATED WITH A DOUBLE SEALANT BEAD APPLICATION IN
ACCORDANCE WITH DETAIL D/A5.2 ON DRAWING SET A5.2.
A4.2
D
A5.4
D
A5.4 D
A5.4
D
A5.4
A4.2
A4.2
A4.2
C
A5.5
C
A5.3
C
A5.4
C
A5.4
C
A5.4
1ST FLOOR NORTH ROOF 1ST FLOOR NORTH EAST ROOF
SET BACK
ROOF B
1ST FLOOR
EAST ROOF
1ST FLOOR SOUTH ROOF
MAIN ROOF
PENTHOUSE ROOF
1ST FLOOR EAST ROOF
SET BACK
ROOF A
ROOF AREA
A4.2
C
A5.4
A4.2
A4.2
C
A5.4
A4.2
A4.2
GROUND FLOOR LEVEL
0'-0"
FIRST FLOOR LEVEL
13'-0"
SECOND FLOOR LEVEL
26'-0"
THIRD FLOOR LEVEL
39'-0"
FOURTH FLOOR LEVEL
52'-0"
FIFTH FLOOR LEVEL
65'-0"
ROOF LEVEL
78'-0"
PENTHOUSE LEVEL
91'-0"
JAY AMMON ARCHITECT, INC.
126 SOUTH PARK AVE., SUITE A • WINTER PARK, FLORIDA 32789
PHONE: (407) 333-1977 • EMAIL: JAY@JAYAMMON.COM
WWW.JAYAMMON.COM
DESIGNED BY:DRAWN BY: APPROVED BY:
DATE: PROJECT NO.:
PHASE
PHASE
NO. DESCRIPTION DATE
REVISION
REV.
NO.
4 4
© 2025: ALL RIGHTS RESERVED. THESE DRAWINGS REMAIN THE PROPERTY OF JAY AMMON ARCHITECT, INC. AND ARE NOT TO BE USED IN ANY OTHER MANNER WITHOUT AGREEMENT IN WRITING BY JAY AMMON ARCHITECT, INC.
CONSULTANT:
CLIENT REF.:
DATE
TO THE BEST OF MY KNOWLEDGE, THESE
DRAWINGS COMPLY WITH THE APPLICABLE
MINIMUM BUILDING CODE REQUIREMENTS.
JAY AMMON AOR: AR0009798
SEAL: CLIENT: PROJECT: SHEET TITLE:
SHEET NO.:SCALE:
DESCRIPTION
1 2 3 4 5 6
6 6
7 7
1 2 3 4 5 6 7
A
B
C
D
A
B
C
D
NORTH BREVARD COUNTY GOVERNMENT COMPLEX
EXTERIOR RESTORATION PROJECT
400 SOUTH STREET,…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .