Parex Stucco Systems.pdf

PDF 5 MB Posted

Attached to
KSU Project No. 275-25-252, Clendenin North South and West Building Envelope Repairs
Solicitation number
PE-54300-RFQC-2025-000000063
Issued by
Cobb County, Georgia

About this file

This document is a technical manual for Parex USA Stucco Details, specifically CSI Section 09 22 00, covering comprehensive stucco assembly installation guidelines and construction details. The manual provides detailed architectural and construction specifications for various stucco assembly configurations, including non-insulated and insulated (HE) general details across different substrate types such as wood frames, steel frames, CMU (concrete masonry unit), and various moisture barrier and insulation approaches. The document includes technical illustrations and diagrams detailing critical construction elements like window openings, expansion joints, roof lines, terminations, and corner treatments, with specific guidance for different building envelope scenarios.

The technical manual emphasizes critical installation considerations, such as ensuring continuous air barriers, proper water-resistive barriers, and appropriate substrate preparation. Parex USA explicitly disclaims liability for design engineering or workmanship, stressing that the details are provided as general guidance and must be used in conjunction with current product specifications, data sheets, and application instructions. The manual covers multiple product variants including Watermaster, Krak-Shield, and standard assemblies, with optional primers and finishes that can be applied with acrylic or elastomeric treatments. While not a contract document, the manual serves as a comprehensive technical reference for architects, contractors, and construction professionals seeking detailed stucco assembly installation guidance.

View the file

Other files

File Type Posted
042000_06_00 Anchor Plates Submittal_EGI.pdf PDF
092423_04_00 Corner Bead Submittal_EGI.pdf PDF
092423_02_00 Control Joint Submittal_EGI.pdf PDF
092400_05_00 Mesh Lath Submittal_EGI.pdf PDF
Clendenin _ Structural Assessment Report_EGI.pdf PDF
071300_01_00 Waterproof Membrane _ Barrier Su.pdf PDF
RFQ for Select Bid Process Clendenin Final.doc DOC document
072100_01_00 Basecoat _ Adhesive Submittal_EG.pdf PDF
072726_01_00 Fluid Applied Permeable Membrane.pdf PDF
Clendenin Enclosure Investigative Report_23_0.pdf PDF
Clendenin Building _ Structural Assessment Re.pdf PDF
092423_05_00 Stucco Assembly Submittal_EGI.pdf PDF
Daily Field Report_24_11_05_Shear Review.pdf PDF
042000_01_00 Brick Ties Submittal_EGI.pdf PDF
Sign_in Sheet 04_08_2025.pdf PDF
042000_05_00 Multipurpose Sealant Submittal_E.pdf PDF
STUCCO COLOR PALETTE_IMG_3261.jpeg JPEG file
042000_02_00 Self Adhering Flashing Submittal.pdf PDF
Existing Clendenin Arch_Struc Drawings.pdf PDF
Addendum 002_RFQ_275_25_252_.docx DOCX document
Addendum 001_RFQ_275_25_252.docx DOCX document
Addendum 003_RFQ_275_25_252_Epsten rev KM.pdf PDF
Clendenin Bulletin 2_Combined Set.pdf PDF
092423_03_00 Casing Bead Submittal_EGI (Rev1).pdf PDF
092423_01_00 Preblended Stucco Submittal_EGI.pdf PDF
042000_03 Weep Holes Submittal_EGI.pdf PDF
042000_04_00 Termination Bar Submittal_EGI.pdf PDF
Clendenin _NWS_ Bid Form.doc DOC document
071300_02_00 Weather Resistive Barrier Submit.pdf PDF
Instructions to Bidders_Clendenin NWS.docx DOCX document
076200_01_00 Flashing _ Joint Filler Submitta.pdf PDF
Clendenin NWS _Suppl Cond State Rev 081924.doc DOC document
Clendenin _ Field Observation Report.pdf PDF
099113_01_00 Acrylic Finish Submittal_EGI.pdf PDF
RFQ for Select Bid Process Clendenin Final.doc DOC document
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Parex USA Stucco Details

CSI SECTION 09 22 00

Note: The design specifications and construction shall comply with all local building codes and standards.

Parex USA installation guidelines are for general information and guidance only and Parex USA specifically disclaims any liability for the use of this design, and for design engineering, or workmanship of any project. The assembly shall be designed to prevent condensation within the assembly. The designer and the user shall provide final drawings and specifications. Products shown other than those manufactured by Parex USA are shown for clarity of the Parex USA product only. Contact the Manufacturer for installation instructions.

Note: To ensure a continuous air barrier across the building envelope, a continuous air seal should be made at each substrate change, joints/gaps, penetrations and dissimilar material terminations. There must be a consideration of the Designer in the overall wall assembly design. Stucco claddings and any cladding using a mortar bed require the use of a slipsheet installed over the Water-Resistive & Air Barrier Coating to prevent adhesion to the stucco.

The drawings, and any related notes, or text contained thereon are based upon typical requirements of Parex USA Stucco Assembly and are published strictly as a guide for architectural and construction industry professionals to illustrate typical or general design conditions.

These details are not to be used by themselves, and do not constitute design instructions for Parex USA Stucco Assembly application. These details must be used in conjunction with Parex USA current product specifications, product data sheets, and application instructions.

Any details shown are strictly for the purpose of illustrating typical Parex USA Stucco Assembly design applications. Any other materials shown in any details are incidental to the details, and are included only for clarity of the Parex USA Stucco Assembly detail. Please consult with the manufacturers and/or suppliers of any separate materials for their product specifications and applications instructions.

Where site or design conditions not shown in these details are present, or any unusual design is involved, please consult with Parex USA Technical Department for assistance.

PAREX USA DOES NOT WARRANT THE FITNESS OF

SUITABILITY OF THESE DETAILS FOR CONSTRUCTION, OR

ASSUME ANY LIABILITY FOR USE OF THESE DETAILS. IT

IS THE SOLE RESPONSIBILITY OF ANY ARCHITECTURAL

OR CONSTRUCTION INDUSTRY PROFESSIONAL TO APPLY

THEIR PROFESSIONAL KNOWLEDGE IN UTILIZING THE

INFORMATION CONTAINED IN THESE DETAILS.

SECTION 1 pagE 3

Non Insulated General Details

SECTION 2 pagE 24

Insulated (HE) General Details

SECTION 1 CONTENT NON INSULATED GENERAL DETAILS

Subject Detail Page aeSthetic FeatureS A1.01 EPS FEATURE OVER STUCCO ASSEMBLY general conStruction G1.01 STUCCO ASSEMBLY / WOOD FRAME

G1.02 STUCCO ASSEMBLY / WATERMASTER / WOOD FRAME

G1.03 STUCCO ASSEMBLY / KRAK-SHIELD / WOOD FRAME

G1.04 STUCCO ASSEMBLY / WATERMASTER /

KRAK-SHIELD / WOOD FRAME

G1.05 STUCCO ASSEMBLY / OPEN FRAME / WOOD FRAME

G1.06 STUCCO ASSEMBLY / STEEL FRAME

G1.07 STUCCO ASSEMBLY / WATERMASTER / STEEL FRAME

G1.08 STUCCO ASSEMBLY / KRAK-SHIELD / STEEL FRAME

G1.09 STUCCO ASSEMBLY / WATERMASTER /

KRAK-SHIELD / STEEL FRAME

G1.10 STUCCO ASSEMBLY / CMU

G1.11 STUCCO ASSEMBLY / WATERMASTER / CMU

G1.12A ROUGH WINDOW OPENING 1 OF 4

G1.12B ROUGH WINDOW OPENING 2 OF 4

G1.12C ROUGH WINDOW OPENING 3 OF 4

G1.12D ROUGH WINDOW OPENING 4 OF 4

G1.13A ALTERNATE WINDOW FLASHING PROCEDURE 1 OF 2

G1.13B ALTERNATE WINDOW FLASHING PROCEDURE 2 OF 2

G1.14 TYPICAL EXPANSION & CONTROL JOINT LOCATIONS

G1.15 INSIDE CORNER

G1.16 OUTSIDE CORNER

exPanSion jointS E1.01 EXPANSION JOINT

E1.01A EXPANSION JOINT WITH FLASHING

E1.02 CONTROL JOINT

E1.03 CASING BEAD TERMINATION

E1.04 DISSIMILAR SUBSTRATE

rooF line R1.01 DOUBLE FACE PARAPET / WOOD FRAME

R1.02 TERMINATION AT DECK GABLE FLASHING

R1.03 TERMINATION AT SOFFIT

R1.04 TERMINATION AT WALL DIVERTER

terminationS T1.01 TERMINATION AT GRADE

T1.02 TERMINATION AT PAVEMENT

WinDoWS W1.01 TERMINATION AT WINDOW JAMB

W1.02 TERMINATION AT WINDOW HEAD

W1.03 TERMINATION AT WINDOW SILL

W1.04 TERMINATION AT FINNED WINDOW SILL

Please refer to the note on the front cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 3 aeSthetic FeatureS general conStruction

A1.01 EPS FEATURE OVER STUCCO ASSEMBLY

G1.01 STUCCO ASSEMBLY-WOOD FRAME

o HE o KRAK-SHIELD n WATERMASTER o HE o KRAK-SHIELD o WATERMASTER

4 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.02 STUCCO ASSEMBLY-WATERMASTER-WOOD FRAME

G1.03 STUCCO ASSEMBLY-KRAK-SHIELD-WOOD FRAME

general conStruction o HE n KRAK-SHIELD o WATERMASTER cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 5

G1.04 STUCCO ASSEMBLY-WATERMASTER-KRAK-SHIELD-WOOD FRAME

G1.05 STUCCO ASSEMBLY-OPEN FRAME-WOOD FRAME

general conStruction o HE n KRAK-SHIELD n WATERMASTER

6 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.06 STUCCO ASSEMBLY-STEEL FRAME

G1.07 STUCCO ASSEMBLY-WATERMASTER-STEEL FRAME

general conStruction cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 7

G1.08 STUCCO ASSEMBLY-KRAK-SHIELD-STEEL FRAME

G1.09 STUCCO ASSEMBLY-WATERMASTER-KRAK-SHIELD-STEEL FRAME

general conStruction o HE n KRAK-SHIELD o WATERMASTER o HE n KRAK-SHIELD n WATERMASTER

8 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.10 STUCCO ASSEMBLY-CMU

G1.11 STUCCO ASSEMBLY-WATERMASTER-CMU

general conStruction cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 9

G1.12A ROUGH WINDOW OPENING 1 OF 4

general conStruction

10 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.12B ROUGH WINDOW OPENING 2 OF 4

cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 11

G1.12C ROUGH WINDOW OPENING 3 OF 4

12 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.12D ROUGH WINDOW OPENING 4 OF 4

cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 13 general conStruction

G1.13A ALTERNATE WINDOW FLASHING PROCEDURE 1 OF 2

14 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

general conStruction

G1.13B ALTERNATE WINDOW FLASHING PROCEDURE 2 OF 2

cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 15

G1.14 TYPICAL EXPANSION AND CONTROL JOINT LOCATIONS

G1.15 INSIDE CORNER

general conStruction

16 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.16 OUTSIDE CORNER

E1.01 EXPANSION JOINT

general conStruction exPanSion jointS cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 17 exPanSion jointS

E1.01A EXPANSION JOINT WITH FLASHING

E1.02 CONTROL JOINT

18 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

exPanSion jointS

E1.03 CASING BEAD TERMINATION

E1.04 DISSIMILAR SUBSTRATE

cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 19 rooF line

R1.01 DOUBLE FACED PARAPET-WOOD FRAME

R1.02 TERMINATION AT DECK GABLE FLASHING

20 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

rooF line

R1.03 TERMINATION AT SOFFIT

R1.04 TERMINATION AT WALL DIVERTER

cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 21 terminationS

T1.01 TERMINATION AT GRADE

T1.02 TERMINATION AT PAVEMENT

22 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

WinDoWS

W1.01 TERMINATION AT WINDOW JAMB

W1.02 TERMINATION AT WINDOW HEAD

cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 23

WinDoWS

W1.03 TERMINATION AT WINDOW SILL

W1.04 TERMINATION AT FINNED WINDOW SILL

SECTION 2 CONTENT INSULATED (HE) GENERAL DETAILS

Subject Detail Page aeSthetic FeatureS A1.01 HE / EPS FEATURE OVER STUCCO ASSEMBLY general conStruction G1.01 HE / STUCCO ASSEMBLY / WOOD FRAME

G1.02 HE / STUCCO ASSEMBLY / WATERMASTER /

WOOD FRAME

G1.03 HE / STUCCO ASSEMBLY / KRAK-SHIELD / WOOD FRAME ... 26

G1.04 HE / STUCCO ASSEMBLY / WATERMASTER /

KRAK-SHIELD / WOOD FRAME

G1.05 HE / STUCCO ASSEMBLY / OPEN FRAME / WOOD FRAME ... 27

G1.06 HE / STUCCO ASSEMBLY / WATERMASTER / STEEL FRAME.. 28

G1.07 HE / STUCCO ASSEMBLY / KRAK-SHIELD / STEEL FRAME

G1.08 HE / STUCCO ASSEMBLY / WATERMASTER /

KRAK-SHIELD / STEEL FRAME

G1.09 HE / STUCCO ASSEMBLY / CMU

G1.10 HE / STUCCO ASSEMBLY / WATERMASTER / CMU

G1.11 HE / STUCCO ASSEMBLY / KRAK-SHIELD / CMU

G1.12 HE / STUCCO ASSEMBLY / WATERMASTER /

KRAK-SHIELD / CMU

G1.13 HE / STUCCO ASSEMBLY / DRAINAGE MAT /

STEEL FRAME

G1.14 HE / STUCCO ASSEMBLY / DRAINAGE TYPE WRAP /

STEEL FRAME

G1.15 HE / STUCCO ASSEMBLY / GROOVED BOARD /

STEEL FRAME

G1.16 HE / STUCCO ASSEMBLY / VERTICAL RIBBONS /

STEEL FRAME

G1.17 HE / INSIDE CORNER

G1.18 HE / OUTSIDE CORNER

exPanSion jointS E1.01 HE / EXPANSION JOINT

E1.02 HE / DISSIMILAR SUBSTRATE

E1.03 HE / CASING BEAD TERMINATION

rooF line R1.01 HE / DOUBLE FACED PARAPET / WOOD FRAME

R1.02 HE / TERMINATION AT DECK GABLE FLASHING

R1.03 HE / TERMINATION AT SOFFIT

R1.04 HE / TERMINATION AT WALL DIVERTER

terminationS T1.01 HE / TERMINATION AT GRADE

T1.02 HE / TERMINATION AT PAVEMENT

WinDoWS W1.01 HE / TERMINATION AT WINDOW JAMB

W1.02 HE / TERMINATION AT WINDOW HEAD

W1.03 HE / TERMINATION AT WINDOW SILL

cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 25 aeSthetic FeatureS

INSULaTED (HE) gENERaL DETaILS

A1.01 HE-EPS FEATURE OVER STUCCO ASSEMBLY

G1.01 HE-STUCCO ASSEMBLY-WOOD FRAME

general conStruction n HE o KRAK-SHIELD n WATERMASTER

26 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.02 HE-STUCCO ASSEMBLY-WATERMASTER-WOOD FRAME

G1.03 HE-STUCCO ASSEMBLY-KRAK-SHIELD-WOOD FRAME

general conStruction n HE n KRAK-SHIELD n WATERMASTER cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 27

G1.04 HE-STUCCO ASSEMBLY-WATERMASTER-KRAK-SHIELD-WOOD FRAME

G1.05 HE-STUCCO ASSEMBLY-OPEN FRAME-WOOD FRAME

general conStruction n HE o KRAK-SHIELD o WATERMASTER

28 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.06 HE-STUCCO ASSEMBLY-WATERMASTER-STEEL FRAME

G1.07 HE-STUCCO ASSEMBLY-KRAK-SHIELD-STEEL FRAME

general conStruction n HE n KRAK-SHIELD o WATERMASTER cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 29

G1.08 HE-STUCCO ASSEMBLY-WATERMASTER-KRAK-SHIELD-STEEL FRAME

G1.09 HE-STUCCO ASSEMBLY-CMU

general conStruction

30 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.10 HE-STUCCO ASSEMBLY-WATERMASTER-CMU

G1.11 HE-STUCCO ASSEMBLY-KRAK-SHIELD-CMU

general conStruction n HE n KRAK-SHIELD o WATERMASTER cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 31

G1.12 HE-STUCCO ASSEMBLY-WATERMASTER-KRAK-SHIELD-CMU

G1.13 HE-STUCCO ASSEMBLY-DRAINAGE MAT-STEEL FRAME

general conStruction

32 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.14 HE-STUCCO ASSEMBLY-DRAINAGE TYPE WRAP-STEEL FRAME

G1.15 HE-STUCCO ASSEMBLY- GROOVED BOARD -STEEL FRAME

general conStruction cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 33

G1.16 HE-STUCCO ASSEMBLY-VERTICAL RIBBONS STEEL FRAME

G1.17 HE-INSIDE CORNER

general conStruction

34 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

G1.18 HE-OUTSIDE CORNER

E1.01 HE-EXPANSION JOINT

general conStruction exPanSion jointS cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 35

E1.02 HE-DISSIMILAR SUBSTRATE

E1.03 HE-CASING BEAD TERMINATION

exPanSion jointS

36 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

R1.01 HE-DOUBLE FACED PARAPET-WOOD FRAME

R1.02 HE-TERMINATION AT DECK GABLE FLASHING

rooF line cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 37

R1.03 HE-TERMINATION AT SOFFIT

R1.04 HE-TERMINATION AT WALL DIVERTER

rooF line

38 • Parex USA Stucco / Stucco HE Details cover before reviewing these details.

T1.01 HE-TERMINATION AT GRADE

T1.02 HE-TERMINATION AT PAVEMENT

terminationS cover before reviewing these details. Parex USA Stucco / Stucco HE Details • 39

W1.01 HE-TERMINATION AT WINDOW JAMB

W1.02 HE-TERMINATION AT WINDOW HEAD

WinDoWS

Facilities French Camp, CA North Hollywood, CA Riverside, CA Colorado Springs, CO Haines City, FL

Corporate Office Parex USA, Inc.

4125 E. La Palma Ave., Suite 250 Anaheim, CA 92807

(866) 516-0061 Tech Support: (800) 226-2424

Duluth, GA Redan, GA Albuquerque, NM Allentown, PA San Antonio, TX

© Parex USA, Inc. July 2013 • PU Stucco DB 0713

Parex USA Stucco Details

CSI SECTION 09 22 00

W1.03 HE-TERMINATION AT WINDOW SILL

WinDoWS

File details come from the government source that posted it. Updated .