092423_05_00 Stucco Assembly Submittal_EGI.pdf
PDF 4 MB Posted
- Solicitation number
- PE-54300-RFQC-2025-000000063
- Issued by
- Cobb County, Georgia
About this file
This document is a technical product submittal for the Parex USA Stucco Systems Application Guide, involving F.H. Paschen, S.N. Nielsen & Associates LLC and Kennesaw State University's Bailey Sports Complex Envelope Repairs project. The comprehensive guide details technical specifications, installation procedures, mixing instructions, and application methods for stucco base coats, water-resistive barriers, mesh reinforcement, finishes, and related construction materials. The submittal covers multiple product lines including WeatherSeal spray and roll-on waterproof membrane, various reinforcing meshes, stucco base coats, level coats, and finish systems designed for different substrate types and environmental conditions.
The guide provides extensive technical details for contractors, including environmental conditions for application, surface preparation requirements, mixing protocols, application techniques, curing instructions, and compatibility considerations for different substrates like wood sheathing, concrete, masonry, and continuous insulation systems. Product specifications include performance characteristics such as water resistance, air infiltration ratings, elongation capabilities, tensile strength, and compliance with various industry standards like ASTM, ICC, and building code requirements. The documentation emphasizes proper installation techniques to prevent moisture intrusion, ensure structural integrity, and achieve optimal performance across different architectural and construction contexts.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F.H. PASCHEN, S.N. NIELSEN & ASSOCIATES LLC
1344 La France Street, NE Suite 2, Atlanta, GA 30307
p. 404.942.1307 f. 404.228.4050 | www.fhpaschen.com
SUBMITTAL COVER SHEET
Fill out items 1 through 4 below and submit product data sheet, sample, shop drawing, or other items submitted to the
Owner/Architect/Engineer. Each submittal line item shall have its own Submittal Cover Sheet.
Project Name: KSU Bailey Sports Complex Envelope Repairs Contractor: FH Paschen
Project Manager: Justice Hill
Address:
739 Trabert Ave NW
Atlanta, GA 30318
Phone: 770-584-4267
Architect/Engineer: RJ Wells – Epsten Group Owner: Kennesaw State University
Owner Project
Manager:
Emmanuel Bertrand - KSU
1. Date: ________9/23/24 _____
2. Submitted Item: _____Stucco Assembly
3. Manufacturer: _____Parex
4. Notes: ____Combined Stucco Assembly & Parex Application Guide
Contractor’s Stamp Owner/ Engineer/ Architect Stamp
No exception taken.
Revise as noted. Do not resubmit. See Notes above.
Revise as noted. Resubmit. See Notes above.
Rejected. See Notes above.
Checking of submittals is only for general conformance with the design concept of the Project and general compliance with the information given in Contract Documents. Any action shown is subject to the requirements of the Drawings and Specifications. Contractor is responsible for dimensions to be confirmed and correlated at the job site, quantities, information that pertains solely to the fabrication processes or to techniques of construction, coordination of the work of all trades, and the satisfactory performance of his work.
By: Date:
melikeduyaroglu Submittal
DESCRIPTION
n 100% Acrylic elastomeric waterproof membrane and air barrier which can be either rolled, brushed, or spray applied.
n Extremely flexible: can bridge cracks and accommodate small movements up to 1/32 in. (0.8mm).
n Designed for use as water-resistive barrier behind exterior claddings n Bridges 1/4 in. (6mm) gaps at sheathing board joints with WeatherTech 396 Sheathing Tape embedded.
n Color: Light Blue
USES
n Water-resistive barrier coating for application to glass mat gypsum sheathing, exterior-grade gypsum sheathing, CDX plywood, OSB, concrete, CMU, brick and cement board sheathing (Consult “Acceptable Substrate and Area of Use” Technical bulletin for more details.)
n Contact the Parex USA Technical Services Department for further options.
COMPOSITION
n Binder base: 100% acrylic elastomeric polymer with surface-hardening property.
n Water based VOC compliant n Solids:
By weight: 68% By volume: 54% n Appearance: Flat non-gloss smooth finish.
EVALUATION REPORT & TESTING
n ABAA Evaluated - ASTM 2357
Compliant n ASHRAE 90.1 Compliant n ASHRAE 189.1 Compliant n ICC Code Recognition n ESR 2045 Compliant
WeatherSeal Spray & Roll-On Waterproof Membrane & Air Barrier
COVERAGE
Depending on the condition of the substrate and method of application, see approximate coverage in the table below.
CONTAINER:
55 lb (25.0 kg) net weight in plastic pails n Storage: Protect from sun and freezing at all times.
n Do not stack pails more than 3 pails high.
n Shelf Life: Reference Parex USA
Expiration Date of Products Technical Bulletin.
DRYING TIME:
Typically 1– 4 hours depending upon temperature, humidity and substrate.
CLEAN-UP
Water soluble prior to drying. Clean tools and containers with water prior to drying.
SURFACE PREPARATION
n Remove surface contaminants such as dust or dirt without damaging the substrate.
n Painted substrates must have the paint removed by methods which result in no more than 10 percent of the remaining surface having paint.
n For additional options for surface preparation, contact Parex USA Technical Support.
MIXING
n Use clean equipment for mixing and preparation.
n Stir WeatherSeal Spray & Roll-On to a uniform consistency. Avoid creating air bubbles or foam.
n For some spray applications it may be necessary to thin WeatherSeal Spray & Roll-On slightly. Use only clean potable water and add sparingly, never more than 16 oz (0.5L) per pail, because thinning can reduce film thickness.
n No additives of any kind, such as rapid binders, anti-freeze, accelerators, fillers, pigments, etc. should be added under any circumstances.
APPLICATION
n Read the entire label before using this product.
n Install the substrate according to manufacturer’s recommendation and according to the Suitable Substrate and Area of Use Technical Bulletin.
n WeatherSeal Spray & Roll-On is easily applied with roller, brush or suitable spray equipment. For sprayed applications, See Parex USA Technical Bulletin for Spraying WeatherSeal Spray & Roll-On.
n For spray applications, strain the material using a paint strainer.
ROLLER APPLICATION
n Use 3/4 in. to 1 1/4 in. (19-32mm) nap roller designed for applying latex paints.
n Apply WeatherSeal Spray & Roll-On approximately 6 in. (150mm) wide centered over:
– Sheathing joints
– Gaps in sheathing up to 1/4 in.
(6mm) wide
– Open holes up to 1 in. (25mm) across
– Back flanges of flashings and track
– Immediately place the
WeatherTech 396 Sheathing Joint Tape centered in the wet WeatherSeal Spray & Roll-On. Run a trowel or taping knife over the sheathing joint tape to embed it and into the wet WeatherSeal Spray & Roll-On up into it. Do not let WeatherSeal Spray & Roll-On skin over before applying and embedding WeatherTech 396 Sheathing Joint Tape. Work in small enough areas to ensure that WeatherSeal Spray & Roll-On is wet when WeatherTech 396 Sheathing Joint Tape is embedded in it. If WeatherSeal Spray & Roll-On does skin over before embedding WeatherTech 396 Sheathing Joint Tape, scrape off semi-liquid WeatherSeal Spray & Roll-On or let it dry and re-apply. Correct larger gaps and holes by replacing sheathing.
– An alternative method for joint treatment is to use WeatherTech WeatherFlash. Work WeatherfFlash flush with the surface. Overlap both
Sheathing Number of minimum Coats on Average required for full coverage
Average Coverage Per Coat
Average Coverage Per Pail Application Notes
Embedding 4” Wide WeatherTech Sheathing Joint Tape
500 lineal feet
Fiberglass Faced & Exterior Grade Gypsum Sheathing
1 coat 350-400 ft2 350-400 ft2 Thicker applications can cause running an dripping of the product.
Plywood PS-1 C/D or PS-2 C/D 2 coats 500 ft2 250-300 ft2 Normal irregularities in the profile, will produce variation in dry film thickness.
Plywood PS-1 C plugged (or better) 1 coat 350-400 ft2 350-400 ft2 Thicker applications can cause running and dripping of the product.
Oriented Strand Board (OSB) 2 coats 500 ft2 250-300 ft2
The edges of the exposed wood strands can sometimes swell from the application of the Weatherseal causing breaks in the coating, which must be touched up before application of the cladding.
Fiber-Mat Reinforced Cementitious Backer Units 2 coats 500 ft2 250-300 ft2
Cast or Precast concrete 1 coat 350-400 ft2 350-400 ft2 If voids exist, they must be filled or leveled with Stucco Level Coat before application of the WeatherSeal Spray & Roll-On.
Concrete Masonry Units
2 coats
1 Coat after skimming with Stucco Level Coat
350-400 ft2
350-400 ft2
175-200 ft2
350-400 ft2
If voids still exist after 2 coats – additional coats may be necessary, coverage is dependant upon porosity.
Weatherseal Trowel-on may be applied in a single coat over CMU if leveled out with Stucco Level Coat before application of Weatherseal Spray & Roll-On.
sides of the gap onto sheathing min 1”. See WeatherTech Data Sheet for details n After Weather Tech 396 Sheathing Joint tape is completely embedded, apply WeatherSeal Spray & Roll-On over the entire outer sheathing surface, at a rate of not more than 100 ft2 per gal.
(2.4 m2. per L), approximately 10–12 wet mils. Normal irregularities in the profile, will occure in OSB, plywood, cement board and CMU, therefore a variation in dry film thickness is normal. The transparency of the dry WeatherSeal Spray & Roll-On is not an indication of the thickness.
n For specific installation details refer to Parex USA Water Resistive Barriers Details at http://www.parex.com/ details/PUSAWRBD.pdf.
LIMITATIONS
n Ambient and surface temperatures must be 40ºF (4ºC) or higher during application and drying time. Provide supplemental heat and protection from precipitation as needed.
n Use only on surfaces that are sound, clean, dry, and free from any residue which may affect the ability of the WeatherSeal Spray & Roll-On to bond to the surface.
n Not for use below grade.
n Not for water immersion.
n WeatherSeal Spray & Roll-On may be left unprotected on the wall for up to 6 months. However, the surface must be clean of all dirt and contaminants before the application of EIFS adhesive. Contact Parex USA Technical Support in case of longer exposures.
WARNING
n Read complete Warning information printed on product container prior to use. For medical emergency information, call 1-800-424-9300.
n For more information on handling this product refer to its Safety Data Sheet (SDS). The most current SDS and Product Data Sheet (PDS) can be found on our website.
n This Product Data Sheet has been prepared in good faith on the basis of information available at the time of publication. It is intended to provide users with information about the guidelines for the proper use and application of the covered product(s) under normal environmental and working conditions. Because each project is different, Parex USA, Inc. cannot be responsible for the consequences of variations in such conditions, or for unforeseen conditions.
WeatherSeal Spray & Roll-On Testing Method ICC and ASTM E2570 Criteria Results
Accelerated Weathering AC 212
25 Cycles followed by Hydrostatic Pressure Test: No water penetration on the plane of the exterior facing side of the substrate.
Pass: No water penetration
Air Infiltration ASTM E2178
Calculated flow Rate at 75 Pa (1.57 lb/ft2, 0.3 in H2O) =
< 0.02 L/m2*s (< 0.004 cfm/ft2)
< .00001 L/m2*s (0.00001 cfm/ft2) at 75 Pa (1.57 lb/ft2,
0.3 in H2O)
Air Leakage of Air Barrier Assemblies ASTM E2357 ASTM E2357 Pass: < 0.2 L/s·m2 at 75 Pa)
(< 0.04 cfm / ft2 at 1.57 psf)
Air Leakage ASTM E283 No Criteria < 0.004 cfm/ft2
Elongation ASTM D412 No Criteria 360%
Tensile Bond ASTM D4541 >15 psi 28 psi
Freeze-Thaw Resistance ASTM E 2485 10 Cycles Pass: No Deleterious Effects
Hydrostatic Pressure Test
AATCC 127
(Water Column)
Resist 21.6 in (55 cm) water for 5 hours before and after aging Pass: No water penetration
Nail Seal ability, Head of Water ASTM D1970 No Criteria Pass: 5 inches of water
Evaluation of Fire Propagation NFPA 285 In Accordance with IBC Chapter 26 Meets requirements for use on all types of construction
Radiant heat exposure NFPA 268 In Accordance with IBC Chapter 26 No ignition upon 20 minute radiant heat exposure at
1.25 w/cm2.
Racking ASTM E72 Deflection at ⅛ in (3.2mm) Pass: No cracking at field, joints or flashing connection
Restrained Environmental ICC ES AC 212 / ASTM E2570 5 Cycles of wetting and drying Pass: No cracking at field, joints or flashing connection
Structural Loading ASTM E1233 Procedure A 10 Cycles @ 80% design load Pass: No cracking at field, joints or flashing connection
Surface Burning Characteristics ASTM E84
Flame Spread <25 Smoke Developed <450
Flame Spread =0 Smoke Developed =0
Tensile Bond Strength ASTM E 2134/ ASTM C 297 Minimum 15 psi (104 kPa) Pass all listed substrates and flashing materials
Water Resistance ASTM D 2247 14 Days Pass: No Deleterious Effects.
Water Penetration ASTM E331 2.86 psf (137 Pa) for 15 minutes Pass: 25.4 psf (1216 Pa) for 165 minutes
Water Penetration ASTM E331
Tested after Structural Loading, Racking and Restrained Environmental Cycling at 2.86 psf (137 Pa) for 15 minutes
Pass: No Water Penetration
Water vapor transmission ASTM E96 Procedure B Vapor Permeable 12.0 perms
Weathering ICC ES AC 212
/ ASTM E2570
210 hours of UV Exposure, 25 cycles of accelerated weathering,
21.6 in (549mm) water column for 5 hours
Pass
Wind Driven Rain F.S. TT-C-555B No Criteria Pass
VOC EPA Reference Test Method 24
US EPA, South Coast AQMD and Greenseal Standard
10 g/L (Meets SCAQMD Rule 1113)
Regional Harvest LEED MRc 5.1 100% at all facilities
Parex USA, Inc., a California Corporation 4125 E. La Palma Ave., Suite 250 Anaheim, CA 92807 www.parexusa.com 866-516-0061 Tech Support: 800-226-2424
© 2019 Parex USA, Inc. January 2019 • PU WSSR DS 0119
365 Flashing Membrane 396 Sheathing Tape
365 FLASHING MEMBRANE
DESCRIPTION
n 365 Flashing Membrane is a high performance tape designed for use with stucco and CI systems to seal around penetrations and at sheathing joints and window/door flanges. It can be applied to most substrates without the use of primer or mechanical fasteners. The polyester fabric top layer provides a excellent bonding surface for cementitious and acrylic finishes.
n 365 Flashing membrane has a split release linger for easy application and seals around properly installed fasteners.
n Sticks to substrates -20° F and has no VOC’s, HFCC’s, nor CFC’s.
PACKAGING
Unit Size (sold only by the box) n 6 in x 75 ft. (15cm x 22.9m)
STORAGE
Store in a dry area and out of direct sunlight in the original unopened container temperatures between 40°F to 90°F (4°C to 32°C). Do not remove materials from original containers until ready for use.
SHELF LIFE
Reference Parex USA Expiration Date of Products Technical Bulletin.
LIMITATION
n Not recommended to be exposed for more than 30 days.
n Not recommended to be applied over uncured (wet) sealants and adhesives, even if compatible.
n Not recommended to use on substrates with standing water or visibly wet surfaces, dirty surfaces, frozen surfaces or surfaces contain anted with foreign substances such as grease, oil or solvents.
n Not recommended for use when in direct contact with PVC type roofing membranes.
n Can be applied in extreme cold/hot weather; however Parex USA does not recommend applying below 0°F (-18°C) or above 125°F (52°C).
365 Flashing Membrane Method Results
Color White
Thickness 17 mil
Self Sealability
ASTM D1970
Section 7.9
Pass
Moisture Vapor Transmission ASTM E96 Wet Cup 0.270 Perms Dry Cup 0.296 Perms
Cold Temperature Flexibility ASTM C765-73 Passes
Grab Tensile ASTM D5034 Warp 67 lbs / Weft 57 lbs
Tensile Elongation at Max load ASTM D5034 Warp 16% / Weft 107%
Mixed Fungal assessment ASTM G21 No growth at 28 days
In-Service Temperature -45°F/-42°C to 300°F/148.9°C
Installation Temperature -20°F/-28°C to 125°F/51.6°C
Solubility to Water Insoluble
UV Stability 30 days
365 FLASHING MEMBRANE
(cont.)
INSTALLATION
n Joint/seam applications: care should be taken to apply 365 Flashing Membrane to form water-shedding laps.
n Cut the tape to length, remove a small portion of the release liner and apply to substrates, continue to remove the release liner as you firmly roll into place using a “J” roller or hand roller to smooth out any wrinkles, air bubbles or creases.
n End laps should be a minimum 6” and should be rolled to ensure adequate adhesion.
n When applying to exterior gypsum products primer is not needed, provided the surface is clean, dry and free of contaminants and is firmly rolled to ensure full adhesion.
Parex USA, Inc., a California Corporation 4125 E. La Palma Ave., Suite 250 Anaheim, CA 92807
© 2018 Parex USA, Inc. August 2018 • WT M&T DS 0818
396 SHEATHING TAPE
DESCRIPTION
n Description and Use: Non-woven fabric used to tape the joints of the sheathing boards to which a Parex USA water resistive barrier is applied.
n Embed in Parex USA water resistive barrier coatings to seal to flashing and at terminations and rough openings per Parex USA installation instructions.
SHELF LIFE
Reference Parex USA Expiration Date of Products Technical Bulletin.
PACKAGING
n Unit Size (sold in rolls):
396.4 4 in. x 500 ft. (10.16cm x 152.4m)
396.6 6 in. x 500 ft. (15.25cm x 152.4m)
396.9 9 in. x 500 ft. (22.86cm x 152.4m)
WARNING:
n Read complete warning information printed on product container prior to use. For medical emergency information, call 1-800-424-9300.
n For more information on handling this product refer to its Safety Data Sheet (SDS). The most current SDS and Product Data Sheet (PDS) can be found on our website.
n This Product Data Sheet has been prepared in good faith on the basis of information available at the time of publication. It is intended to provide users with information about the guidelines for the proper use and application of the covered product(s) under normal environmental and working conditions. Because each project is different, Parex USA, Inc. cannot be responsible for the consequences of variations in such conditions, or for unforeseen conditions.
2. Manufacturer Parex USA, Inc.
4125 E. La Palma Ave, Suite 250 Anaheim, CA 92807 866-516-0061 www.parexusa.com
3. Product Description BASIC USE: WeatherFlash liquid flashing and joint filler is used to prepare and seal exterior wall rough openings and detail joints as part of the WeatherTech air and water barrier system.
Uses: WeatherFlash is applied to exterior wall assemblies where it functions as part of an air and water resistive barrier system.
WeatherFlash is an all-purpose, liquid applied flashing used in construction applications to bridge dissimilar materials and to create weather resistant, fully adhered pan membranes in window and door installations.
Liquid Flashing can be applied over surfaces and substrates that have been prepared per the WeatherTech Guidelines. WeatherFlash bonds to most construction materials, such as aluminum, brick, concrete, wood, vinyl, exterior gypsum board, and various other construction substrates.
Areas of Use
• Window and door rough openings
• Sheathing joints
• Fastener points
• Wall penetrations (Beams, pipes, utility boxes, etc.)
Advantages
• Single stage product – No mixing needed
• One step application – No primer required
• Flashing Fabrics are optional
• Superior shore hardness – Prevents membrane wear and tear
• Permeable – Allows substrates to breath
• High viscosity – Supports gun and spread applications
• Exceptional adhesion – Bonds to multiple substrates
• Advanced proprietary technology –
Produces a durable seamless membrane
• Environmentally friendly – Solvent free, isocyanate free and low VOC
• Wet surface application – Bonds and cures in wet conditions
• Class A surface burning rated – Provides added fire protection against flame spread and smoke development
• Contains fungicide – Mold resistant
WeatherFlash Liquid Flashing & Joint Filler
Application Joint and Gap Filler:
• Fill any and all visible gaps in rough openings and joints with WeatherFlash. Joints of that are 1/4” or greater will require the use of a backer rod prior to the WeatherFlash application. In joints too shallow for backer rod, use a polyethylene bond-breaker tape to prevent three-sided adhesion.
• Work WeatherFlash flush with surface of substrate using a putty knife or trowel.
• Overlap both sodes of the gap onto the sheathing a minimum of 1”.
• Allow to skin over before installing WeatherTech products.
Liquid Flashing Step 1 - Exterior Wall: Apply ½” bead of WeatherFlash in a “Zig-Zag” pattern to exterior wall surface adjacent to the rough opening.
• Spread the flashing using a flat trowel to create a monolithic flashing membrane. Extend flashing 4 – 6 inches beyond the rough opening on exterior side of wall surface. Apply additional flashing to cover all voids.
Step 2 - Framing: Apply ½” bead of WeatherFlash in a “Zig-Zag” pattern to all exposed framing located inside the rough opening.
• Spread the flashing using a flat trowel to create a monolithic flashing membrane.
Completely cover the inside of rough opening.
Be sure to extend the flashing out and over flashing previously applied to exterior wall surfaces to create a monolithic membrane. If voids are present, apply additional WeatherFlash as necessary.
• Allow WeatherFlash to cure before installing building components (windows, doors, waterproofing and air barriers).
WeatherFlash, when used as a flashing membrane, is to be applied approximately at a minimum of 30 wet mils.
WeatherFlash is tack-free in 30 minutes at 70°F / 50% RH. Higher temperature and humidity will decrease tack free times, while lower temperature and humidity will extend tack free times.
Limitations
• Do not apply to bonding surfaces that have contamination (oils, dirt, or release agents).
• Not to be used in active joints resulting in movement greater than 12% in compression or extension.
• Not to be used in areas that are subjected to harsh chemicals (acids, strong alkalis, ketones, etc.).
Warning Read complete Warning information prior to use.
For medical emergency information, call 1-800- 424-9300.
• For more information on handling this product refer to its Safety Data Sheet (SDS). The most current SDS and Product Data Sheet (PDS) can be found on our website.
• This Product Data Sheet has been prepared in good faith on the basis of information available at the time of publication. It is intended to provide users with information about the guidelines for the proper use and application of the covered product(s) under normal environmental and working conditions. Because each project is different, Parex USA, Inc. cannot be responsible for the consequences of variations in such conditions, or for unforeseen conditions.
Cleaning: Immediately remove all excess sealant and smears adjacent to joints with mineral spirits. Use mineral spirits for removing uncured sealant from equipment. Remove cured sealant by scraping, sandpaper, etc. (Caution: Mineral spirits is flammable and toxic. Observe cleaning solvent manufacturer’s precautions.)
Coverage Thickness 20 oz. Sausage Tube 10 Mils 25 sq. ft.
20 Mils 13 sq. ft.
30 Mils 8 sq. ft.
6. Availability WeatherFlash is available at leading building material and construction dealers.
7. Warranty Contact Parex USA Technical Services.
8. Maintenance If the sealant is damaged and the bond is intact, cut out the damaged area and reapply WeatherFlash. No primer is required. If the bond has been affected, remove the sealant, clean and prepare the joint in accordance with the instructions above.
9. Technical Services Parex USA maintains technical field representatives available throughout the country.
Call Technical Services at 800-226-2424 for the nearest representative.
4. Technical Data Product Color: Gray
Property Test Method Typical Value
Tensile Strength ASTM D 412 225 PSI
Elongation ASTM D 412 275%
Air Leakage & Durability
ASTM E 2357 =<0.0002@75°F
Skin Time Less than an hour @ 75oF and
50% RH
Lap Shear 275 PSI
Low Tempera-ture Flexibility
Properties re-tained to -75oF
Ultraviolet Radiation (UV) Rating
ASTM G 26 2000+ hours UV-A no change in appearance or physical proper-ties
Volatile Organic Compounds
(VOC)
9g/1 VOC
Packaging: Product is available in 20 oz. (591 ml) sausage packs (20 per Case).
Shelf Life: For maximum shelf life, store unopened product at or below 80°F (27ºC). Shelf life for Sausage Case is 12 months.
5. Installation Surface Preparation: All surfaces must be clean, dry and free of all foreign matter or contamination such as oil, grease, and wax, bitumen, curing compounds, form-release agents or other coatings.
Old caulking materials should be removed from masonry joints to insure optimum performance of the new sealant. Metal surfaces must be free of rust, corrosion and protective coatings.
• Gun and spread as required.
• Surface temperatures must be between
20˚F - 100˚F.
• Product can bee installed to a temperature down to 20˚F but must be stored in a warm environment before use.
• If additional coats of material are required, this product must be cleaned with approved solvent (mineral spirits) and brought back to tacky.
Joint Design: The width or depth of the joint should not be less than 1/8” (3.175 mm).
In joints up to ½” (12 mm), but not exceeding 1 ¼” (31 mm) the depth should be maintained at ½” (12mm).
Parex USA, Inc., a California Corporation 2150 Eastridge Ave.
Riverside, CA 92507 www.parexusa.com 866-516-0061 Tech Support: 800-226-2424
© ParexUSA, Inc. April 2021• WT WFL DS 0421
Product Approvals: Meets AAMA 714-15
Building Confidence™
Dependable, cost-effective building paper Designed to guard against the internal wall damage caused by the intrusion of water or excessive moisture, Henry ® Jumbo Tex ® is a proven Grade “D” weather-resistive barrier that exceeds industry standards.
Specifically developed for use behind fiber cement siding, residential stucco, vinyl and wood siding, Jumbo Tex provides optimal breathability to prevent the potential for moisture condensation within exterior walls.
Part of the Henry ® 1-2-3 moisture control system, Jumbo Tex is backed by an industry-leading 15-year material PLUS labor warranty.
Features and benefits
Delivers two times the water protection of standard Grade “D” paper
Excellent balance between water resistance and permeabilty
Highly cost-effective protection against moisture
Less likely to tear during installation
For residential stucco and stucco applications.
Henry ® Jumbo Tex ® Weather-Resistive Barrier
A step 1 component of the Henry® 1-2-3 Moisture Control System™
Exceeds Federal Specification UU-B-790a, Type 1, Grade “D”, Style 2
Complies with the International Code Council Evaluation Services Acceptance Criteria for Water Resistive Barriers (AC 38)
Complies as an alternative to the water-resistive barrier specified in Section
1404.2 of the 2012 and 2015 International Building Code® and Section 1403.2 of the 2018 International Building Code®
Complies as an alternative to the weather-resistant barriers specified in Section R703.2 of the International Residential Code®
Complies as a water-resistant barrier specified in Section R703.6.3 of the 2012 International Residential Code® and Section R703.7.3 of the 2015 and 2018 International Residential Code®
Complies as a water-resistive barrier specified in Section 2510.6 of the 2012 International Building Code®.
Meets the 2015 and 2018 International Building Code® requirements for an intervening layer when installed over an ASTM E2556, Type II in accordance with the Exception in Section 2510.6
ICC Evaluation Service Report 1027
ASTM D779 – Standard Test Method for Water Resistance of Paper, Paperboard and Other Sheet Materials by the Dry Indicator Test Method
ASTM D828 – Tensile Properties of Paper and Paperboard Using Constant-Rate-of-Elongation Apparatus
Featuring a range of compatible weather barriers, flashings and sealants, the Henry® 1-2-3 Moisture Control System™ makes it easier than ever to build with confidence.
Building Envelope Systems®
Wall & Window | Roof | Foundation
Henry, Jumbo Tex, Moistop and Building Envelope Systems are registered trademarks of the Henry Company
© 2022 Henry Company. All rights reserved.
Printed in U.S.A 215.3US.E450 (04/22)
Ask us today about other Henry ® solutions that help manage the flow of water, air, vapor and energy.
csfhenry@henry.com | 1-800-773-4777 www.henry.com
Limitations: Product should be covered as soon as possible. Inspect product to ensure it is free of any protrusions or damage which may detract from the weather-resistive barrier integrity. Holes, tears or punctures should be sealed with Moistop® Sealant or Henry Sheathing Tape. This product is not recommended for horizontal, below grade or roofing applications.
Installation: Jumbo Tex should be installed in accordance with the local applicable building code. The International Residential Code Section R703.2 states that weather-resistive barriers should be applied horizontally, with the upper layers overlapping the lower layer by a minimum of 2" (3" is recommended), and all vertical joints should be lapped a minimum of 6".
Availability: Henry products are distributed nationwide. For product information and pricing, please call a Henry distributor near you. If you need assistance locating a participating distributor, please call our Customer Service Department at 1-800-773-4777.
Henry Product Warranty Information: This product may be eligible for the 15-year Henry 1-2-3 Moisture Control System Warranty when used in conjunction with other products. See https://us.henry.com/warranty for details.
We, the manufacturer, warrant only that this product is free of defects, since many factors which affect the results obtained from this product – such as weather, workmanship, equipment utilized, and prior condition of the substrate – are all beyond our control. We will replace at no charge any product proved to have a material defect within 12-months of purchase, provided it has been applied in accordance with our written directions for uses we recommend as suitable for this product. Proof of purchase must be provided.
DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY: THIS LIMITED
WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NO ONE,
INCLUDING THE MANUFACTURER, SHALL HAVE ANY LIABILITY OF ANY KIND
BEYOND PRODUCT REPLACEMENT, INCLUDING FOR NEGLIGENCE OR FOR
DIRECT, CONSEQUENTIAL, EXEMPLARY OR INCIDENTAL DAMAGES, RESULTING
FROM ANY MISUSE, DEFECTS OR DELAYS CAUSED BY REPLACEMENT OR
OTHERWISE. IF PURCHASER DOES NOT ACCEPT THESE TERMS, PURCHASER
MAY RETURN WITHIN 30-DAYS OF PURCHASE ALL UNOPENED CONTAINERS
OR PACKAGES OF PRODUCT PURCHASED FOR A FULL REFUND. RETENTION
OF PRODUCT BEYOND 30-DAYS, OR USE OF PRODUCT SHALL CONSTITUTE
ACCEPTANCE OF THESE TERMS, CONDITIONS, AND DISCLAIMERS. THIS
LIMITED WARRANTY AND LIABILITY DISCLAIMER PROVIDES THE PURCHASER’S
EXCLUSIVE REMEDY FOR ANYTHING RELATING TO THE PRODUCT.
To the extent that any part of this LIMITED PRODUCT WARRANTY AND LIABILITY DISCLAIMER is determined unenforceable under the law of the place of purchase of the product, that part is severed and the remainder of these terms remain in full force and effect. To the extent permitted by law, the duration of any implied warranties is limited to the duration of Henry’s express warranty.
This warranty language supersedes any language found elsewhere, including product labels, sell sheets and/or technical documents.
Performance standards you can trust Jumbo Tex is a classic Grade “D” weather-resistive barrier designed for use behind a variety of exterior wall claddings.
It provides excellent protection from internal wall damage due to moisture leakage and condensation.
Jumbo Tex ®
Water vapor transmission 70 grams 10 perms (MVT)
ASTM E96 (A)
Tensile strength MD - 55 lb.f/inch CD - 23 lb.f/inch
ASTM D828
Water resistance 20 minutes ASTM D779
Product characteristics
Product approvals, certifications and specifications
Composition An asphalt-saturated kraft Grade “D” breather type sheathing paper.
Roll size 40" x 97.2 lineal ft. (324 sq. ft.)
40" x 150 lineal ft. (500 sq. ft.)
Weight 3.6 lbs per 100 sq. ft.
Physical/performance property
Typical value
Test method
*Jumbo Tex is tested in accordance with ASTM International procedures.
The values shown in Table 1 are typical values obtained in these tests.
PRODUCT NAME
PAC-CLAD prefinished sheet and coil aluminum and steel
MANUFACTURER
Petersen Aluminum Corporation 1005 Tonne Road Elk Grove Village, IL 60007 P: 800-323-1960 847-228-7150 F: 800-722-7150 pac-clad.com
PRODUCT DESCRIPTION
PAC-CLAD is a pre-finished specification grade aluminum sheet or commercial-quality extra-smooth galvalume steel sheet, primed and coated with Petersen’s full-strength fluoropolymer (PVDF) high-performance coating system of 1.0 mil (0.025 mm) total dry film thickness and, on the reverse side, a wash coat of 0.3 -0.4 mil (0.008-0.01 mm) dry film thickness.
BASIC USE: PAC-CLAD is for general sheet metal use in building applications, as well as formed roofing and wall panels produced by Petersen Aluminum. PAC-CLAD is frequently used in the following forms:
` Roofing and mansard panels
` Wall panels
` Fascia and soffit panels
` Gravel stops and copings
` Store front components
` Flashing and trim
MATERIALS AND FINISHES: PAC-CLAD
consists of either Aluminum Association specification ASTM B209 aluminum sheet, temper H14 or H34; hot-dipped ASTM A 653 Grade A structural quality steel sheets, or ASTM A792 Galvalume commercial weight. PAC-CLAD sheets, coil and panels are coated with a 2-coat system using a combination of 70% Kynar 500®/ Hylar 5000® polyvinylidenefluoride (PVDF), acrylic resins, pigments and solvents. The system consists of Fluropon® top coat applied over a polyester primer. A wash coat is applied to the reverse side for additional protection.
STANDARD SIZES: Aluminum is available in .032”
- .063” (0.8 – 1.6 mm) thickness in 48” (1219
mm) widths. Steel is available in 24 and 22 GA in 48” (1219 mm) widths.
COLORS: For standard colors, refer to Table on Page 2. Custom match colors are available in minimum quantities of 5000 lb (4540 kg) for standard gauges.
FINISH: Sheens available – Dull, matte and specular, gloss rating of 25-35% at 60° viewing angle.
TEXTURES AVAILABLE: Smooth
LIMITATIONS: PAC-CLAD performance depends on the integrity of the coating film.
PAC-CLAD should not be used in areas of high abrasion or where it will be subject to mechanical damage.
TECHNICAL DATA
APPLICABLE STANDARDS:
` Aluminum Association Specifications for Aluminum Structures
` Specifications for Cold Formed Steel Design Manual
` American Architectural Manufacturers Assoc – AAMA 621-02
AMERICAN SOCIETY FOR TESTING & MATERIALS
(ASTM)
` ASTM A792/A792M Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot Dip Process
` ASTM A755/A755M – Standard Specification for Steel Sheet, Metallic Coated by the Hot-Dip Process and Prepainted by the Coil Coating Process for exterior Exposed Building Products
` ASTM B209 Standard Specification for Aluminum and Aluminum Alloy Sheet and Plate
PHYSICAL QUALITY
` ASTM B117-95 – Operating Salt Spray (Fog) Apparatus
` ASTM D 523 – Standard Test for Specular Gloss
` ASTM D 968 – Standard Test Methods for Abrasion Resistance for Organic Coatings by Falling Abrasive
` ASTM D 2244 – Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates
` ASTM D 2247 – Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity
` ASTM D 2794 – Standard Test Method for Resistance of organic Coatings to the Effects of Rapid Deformation (Impact)
` ASTM D 4214 – Standard Test Methods for Evaluating the Degree of Chalking of Exterior Paint Films
` ASTM D 3363 - Standard Test Method for Film Hardness by Pencil Test
` ASTM D 4145 - Standard Test Method for Coating Flexibility of Prepainted Sheet
` ASTM D 3359 - Standard Test Methods for Measuring Adhesion by Tape Test
` ASTM D 1308 - Standard Test Method for Effect of Household Chemicals on Clear and Pigmented Organic Finishes
` ASTM D 522 - Standard Test Methods for Mandrel Bend Test of Attached Organic Coatings
` ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials
NATIONAL COIL COATERS ASSOCIATION (NCAA)
` NCAA Procedure No. 11-5
` NCCA Procedure No. 11-18
` NCCA Technical Bulletin No. 11-6
SHEET METAL & AIR CONDITIONING CONTRACTORS
NATIONAL ASSOCIATION (SMACNA) -
Architectural Sheet Metal Manual
Physical Properties of Fluoropolymer Coating – See PAC-CLAD Chart on Page 2.
INSTALLATION
Methods: Fabricate and install PAC- CLAD sheet metal in accordance with SMACNA sheet metal practices. PAC-CLAD can be cut, formed, nailed, screwed or riveted using conventional hand or power tools.
PAC-CLAD coatings must be mechanically removed if soldering or welding is necessary.
For best results, cutting edges should be kept sharp, clean, properly dressed and closely aligned.
A strippable vinyl film can be applied for protection during fabrication and installation if necessary. Vinyl film may remain on the coating during fabrication and installation.
Vinyl must be removed prior to or immediately after installation.
PAC-CLAD is a finished material; care must be taken during fabrication and erection to avoid damage to the surface. Proper bend radii must be used in fabrication.
Product Data
FLASHING & SHEET METAL | 07 60 00
1005 Tonne Road Elk Grove Village, IL 60007
P: 800-PAC-CLAD
F: 800-722-7150
9060 Junction Drive Annapolis Junction, MD 20701 P: 800-344-1400 F: 301-953-7627
10551 PAC Road Tyler, TX 75707 P: 800-441-8661 F: 903-581-8592
102 Northpoint Parkway Acworth, GA 30102 P: 800-272-4482 F: 770-420-2533
1800 S. 7th Ave., Suite 130 Phoenix, AZ 85007 P: 833-750-1935 F: 602-254-6504
9817 233rd Ave. E Suite A Bonney Lake, WA 98391 P: 253-501-2450
PAC-CLAD® is a registered trademark of Petersen Aluminum Corporation. 4/2023800-PAC-CLAD | PAC-CLAD.COM
REFLECTIVITY EMISSIVITY 3-YEAR
EXPOSURE SRI
STEEL ALUMINUM
24 GA. 22 GA. .032 .040 .050 .063
0.69 to 0.04 0.89 to 0.14 0.69 to 0.04 -2 to 85 44 colors 17 colors 36 colors 23 colors 28 colors 6 colors
NOTE: Colors above are not exact representations of actual PAC-CLAD colors. Ask a PAC representative for a color-chip chart or painted metal samples before making final color selection.
AVAILABILITY & COST
AVAILABILITY: PAC-CLAD sheets are available nationwide and are stocked in standard colors and gauges. Special finishes require additional time for color matching and approvals. Note: 5000 pound minimum for non-standard colors. Delivery time and price to be quoted upon inquiry.
COST: Contact the manufacturer for specific cost.
WARRANTY
A 30-year non-prorated warranty covering color, fade, chalking and film integrity is available at no additional cost. Please see our website for sample warranty. Warranty terms vary slightly for Award Blue and Cardinal Red and metallic finishes. The warranty is issued on a per-project basis upon request. Contact Petersen for specific requirements.
There is no finish warranty available on perforated materials.
MAINTENANCE
Maintenance is not required. The panel finish is a member of the Teflon family and is self-cleaning. If cleaning is desired, panels can be washed with mild soap and water followed by a clean water rinse.
TECHNICAL SERVICES
Technical services are available from Petersen Aluminum Corporation and regional architectural representatives.
STORAGE & PACKAGING
PAC-CLAD sheet and coil should be stored in a clean, dry location. Suitable facilities at the jobsite for storage and protection of the material should be provided and should be well ventilated.
Store material out of traffic areas to prevent dents, bending, abrasion, etc. Materials should be protected with waterproof paper cover – plastic should be avoided to eliminate condensation. Keep the material off the ground in an inclined position.
PAC-CLAD COLOR AVAILABILITY
The chart above indicates performance ranges and availability of all PAC-CLAD colors and materials. For complete information visit pac-clad.com.
Product Data
FLASHING & SHEET METAL | 07 60 00
STANDARD COLORS PREMIUM COLORS
Patina Green*
Arcadia Green*
Teal* Anodic Clear*
Silver*
Weathered Zinc*
Weathered Copper
Silversmith*Mansard Brown*
Zinc*
Champagne*
Weathered Steel
Hemlock Green* Forest Green
Cityscape*
Evergreen* Hunter Green*Hartford Green
Military Blue*
Charcoal*
Berkshire Blue
Award Blue
Pacific Blue*
BurgundyBurnished Slate*
Medium Bronze*
Dark Bronze*
Interstate Blue
Stone White* Almond*Bone White*
Sandstone* Sierra Tan*Granite*
Midnight Bronze
Musket Gray* Slate Gray*Matte Black
Black Aluminum
Graphite*
Aged Bronze*
Terra Cotta* Cardinal Red*Colonial Red*
Copper Penny* Aged Copper*
* Denotes PAC-CLAD Cool Color
HQ: 1005 Tonne Road Elk Grove Village, IL 60007
P: 800-PAC-CLAD
F: 800-722-7150
9060 Junction Drive Annapolis Junction, MD 20701 P: 800-344-1400 F: 301-953-7627
10551 PAC Road Tyler, TX 75707 P: 800-441-8661 F: 903-581-8592
102 Northpoint Parkway Acworth, GA 30102 P: 800-272-4482 F: 770-420-2533
1800 S. 7th Ave., Suite 130 Phoenix, AZ 85007 P: 833-750-1935 F: 602-254-6504
9817 233rd Ave. E Suite A Bonney Lake, WA 98391 P: 253-501-2450
PAC-CLAD® is a registered trademark of Petersen Aluminum Corporation. 4/2023800-PAC-CLAD | PAC-CLAD.COM kconnelly Line kconnelly Line melikeduyaroglu Text Box KSU to select and approve color.
#66X Expanded Flange Casing Bead (XXCB) Expanded flange casing bead or plaster stop
Used as a stucco/plaster stop to provide a screed edge and protective finish trim while terminating plaster or thin stone in a clear, straight line at doors, windows, and other openings. The #66X is recommended as an edge divider between plaster and other dissimilar materials. An expanded flange makes tie-on applications easier.
Not recommended at base of wall in lieu of an FHA-7 Foundation Weep Screed. Designed for use under extreme reinforcement conditions where a standard short flange casing bead will be inadequate. #66X
Casing Beads are available with or without weep holes and available in zinc alloy for advanced corrosion resistance.
Galvanized steel products should not be used with Portland cement stucco containing calcium chloride additives or magnesium oxychloride cement stucco. The selection of the appropriate type of material for accessories shall be determined by the surrounding climatic and environmental conditions such as salt air, high humidity, and industrial pollution.
Product Data & Ordering Information:
Material: 26 Gauge, G60 Hot-Dipped galvanized steel
Also available in 99.97% pure Zinc, compliant with ASTM B69
Dimensions: 1/4" to 1-1/4" Grounds, 10' lengths
Ground Length Pcs./Ctn. Ft./Ctn. Wt./Ctn. Ctn./Skid
1/4" 10' 30 300 46 lbs. 20
3/8" 10' 30 300 46 lbs. 20
1/2" 10' 30 300 46 lbs. 20
5/8" 10' 30 300 49 lbs. 20
3/4" 10' 30 300 49 lbs. 20
7/8" 10' 30 300 54 lbs. 20
1" 10' 30 300 56 lbs. 20
1-1/4" 10' 30 300 60 lbs. 20
Code Approvals & Performance Standards
ASTM A653 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy- Coated (Galvannealed) by the Hot-Dip Process ASTM C1063 Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster ASTM C1861 Standard Specification for Lathing and Furring Accessories, and Fasteners, for Interior and Exterior Portland Cement-Based Plaster SDS For ASTM A653 Steel Finishing Products For Interior Finishing and Exterior Finishing
Storage:
All stored materials shall be kept dry. Materials shall be stacked off the ground, supported on a level platform, and protected from the weather and surface contamination conforming to ASTM C1063.
Limitations:
Galvanized steel products should not be used with magnesium oxychloride cement stucco or Portland cement stucco containing calcium chloride additives. The selection of the appropriate type of material for accessories shall be determined by the surrounding climatic and environmental conditions such as salt air, industrial pollution and high humidity.
Product Submittal Sheet Technical Services: 888-437-3244, Engineering Services: 877-832-3206, Sales 800-543-7140
Stucco 09.22.36 (Metal Lath)
#66X Expanded Flange Casing Bead The technical content of this literature is effective 03/25/24 and supersedes all previous information.
https://www.astm.org/catalogsearch/result/?q=a653 https://www.astm.org/catalogsearch/result/?q=c1063 https://www.astm.org/catalogsearch/result/?q=c1861 https://www.clarkdietrich.com/sites/default/files/media/documents/CD_SDS-Steel_A653.pdf https://www.clarkdietrich.com https://www.clarkdietrich.com/node/169 eifs.conferenceroom Highlight
#1A Expanded Corner Bead (CBXA) Galvanized steel expanded flange corner bead for exterior corners
A solid nose, all-purpose exterior corner bead. Strong and economical with multiple general use purposes.
The wide, expanded-wing flanges are flexible and can compensate for most irregular surfaces providing even grounds and straight corners. The expanded steel near the nose of the corner bead provides multiple plastering and stucco keys allowing for reinforcement and strength where it is needed the most.
In addition to reinforcing corners, the #1A Corner Bead can also be used as a return accessory around any recessed opening or as a corner for spray-applied fireproofing when the column of bead is boxed in.
Galvanized steel products should not be used with magnesium oxychloride cement stucco or Portland cement stucco containing calcium chloride additives. The selection of the appropriate type of material for accessories shall be determined by the surrounding climatic and environmental conditions such as salt air, industrial pollution, and high humidity. The #1A Corner Bead is available in Zinc for approved corrosion resistance.
Product Data & Ordering Information:
Material: .0172 base steel, 26 Gauge, G-60 Hot-Dipped Galvanized Steel.
Also available in 99.97% pure Zinc, compliant with ASTM B-69.
Dimensions: Nominal 2-7/8" Full Wing Flange
Length Pcs./Ctn. Ft./Ctn. Ctn./Skid Wt./Ctn.
10' 30 300' 20 49 lbs.
Code Approvals & Performance Standards
ASTM A653 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy- Coated (Galvannealed) by the Hot-Dip Process ASTM C1063 Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster ASTM C1861 Standard Specification for Lathing and Furring Accessories, and Fasteners, for Interior and Exterior Portland Cement-Based Plaster Intertek CCRR-0204 Metal Lath - Code Compliance Research Report SDS For ASTM A653 Steel Finishing Products For Interior Finishing and Exterior Finishing
Storage:
All stored materials shall be kept dry. Materials shall be stacked off the ground, supported on a level platform, and protected from the weather and surface contamination conforming to ASTM C1063.
Limitations:
Galvanized steel products should not be used with magnesium oxychloride cement stucco or portland cement stucco containing calcium chloride additives. The selection of the appropriate type of material for accessories shall be determined by the surrounding climatic and environmental conditions such as salt air, industrial pollution and high humidity.
Sustainability Credits For more details and LEED letters contact Technical Services at 888-437-3244 or visit clarkdietrich.com/LEED.
LEED v4.1 MR Credit: Environmental Product Declarations: EPD (1 point) - Sourcing of Raw Materials (up to 2 points) - Material Ingredients (1 point) - Construction and Demolition Waste Management (up to 2 points)
LEED v4 MR Credit: Building Product Disclosure and Optimization: EPD (1 point) - Sourcing of Raw Materials (1 point) - Material Ingredients (1 point) - Construction and Demolition Waste Management (up to 2 points) - Innovation Credit (up to 2 points).
Provides true, straight and accurate corners Flexible for irregular surfaces
Stucco 09.22.36 (Metal Lath)
#1A Expanded Corner Bead The technical content of this literature is effective 05/17/24 and supersedes all previous information.
https://www.astm.org/catalogsearch/result/?q=a653 https://www.astm.org/catalogsearch/result/?q=c1063 https://www.astm.org/catalogsearch/result/?q=c1861 https://specdirect.intertek.com/controls/SDDocumentViewer.aspx?ccrr=CCRR-0204 https://www.clarkdietrich.com/sites/default/files/media/documents/CD_SDS-Steel_A653.pdf https://www.clarkdietrich.com/LEED https://www.clarkdietrich.com https://www.clarkdietrich.com/node/167
#15 Double-V Control Joint (VVCJ) Expanded flange control joint
#15 Expanded Flange Control Joint (Double-V) is used to relieve stresses in large plastered areas of walls, ceilings, and stucco areas. The Double-V Control Joint counteracts the inherent shrinkage during stucco curing and general thermal changes.
This nearly inconspicuous, expanded wing control joint minimizes cracking and assures proper plaster and stucco thickness.
Ground heights include 3/8” for thin coat plaster and 1/2", 5/8", 3/4" and 7/8" for conventional plaster applications. Follow use provisions outlined in ASTM C1063.
The #15 Double-V Control Joint is also available in zinc alloy for increased corrosion resistance.
Product Data & Ordering Information:
Material: 26 Gauge, G-60 Hot-Dipped Galvanized Steel
Also available in 99.97% pure Zinc, compliant with ASTM B69
Grounds: 3/8", 1/2", 5/8", 3/4" and 7/8" Grounds, 10' lengths
Ground Length Pcs./Ctn.
3/8" 10' 24
1/2" 10' 24
5/8" 10' 24
3/4" 10' 24
7/8" 10' 24
Code Approvals & Performance Standards
ASTM A653 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy- Coated (Galvannealed) by the Hot-Dip Process ASTM C1063 Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster ASTM C1861 Standard Specification for Lathing and Furring Accessories, and Fasteners, for Interior and Exterior Portland Cement-Based Plaster SDS For ASTM A653 Steel Finishing Products For Interior Finishing and Exterior Finishing
Storage:
All stored materials shall be kept dry. Materials shall be stacked off the ground, supported on a level platform, and protected from the weather and surface contamination conforming to ASTM C1063.
Limitations:
Galvanized steel products should not be used with magnesium oxychloride cement stucco or Portland cement stucco containing calcium chloride additives. The selection of the appropriate type of material for accessories shall be determined by the surrounding climatic and environmental conditions such as salt air, industrial pollution and high humidity.
Sustainability Credits For more details and LEED letters contact Technical Services at 888-437-3244 or visit clarkdietrich.com/LEED.
LEED v4.1 MR Credit: Environmental Product Declarations: EPD (1 point) - Sourcing of Raw Materials (up to 2 points) - Material Ingredients (1 point) - Construction and Demolition Waste Management (up to 2 points)
LEED v4 MR Credit: Building Product Disclosure and Optimization: EPD (1 point) - Sourcing of Raw Materials (1 point) - Material Ingredients (1 point) - Construction and Demolition Waste Management (up to 2 points) - Innovation Credit (up to 2 points).
Product Submittal Sheet Technical Services: 888-437-3244, Engineering Services: 877-832-3206, Sales 800-543-7140
Drywall 09.22.36 (Metal Lath)
#15 Double-V Control Joint The technical content of this literature is effective 07/31/23 and supersedes all previous information.
https://www.astm.org/catalogsearch/result/?q=a653 https://www.astm.org/catalogsearch/result/?q=c1063 https://www.astm.org/catalogsearch/result/?q=c1861 https://www.clarkdietrich.com/sites/default/files/media/documents/CD_SDS-Steel_A653.pdf https://www.clarkdietrich.com/LEED https://www.clarkdietrich.com…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .