071300_02_00 Weather Resistive Barrier Submit.pdf

PDF 5 MB Posted

Attached to
KSU Project No. 275-25-252, Clendenin North South and West Building Envelope Repairs
Solicitation number
PE-54300-RFQC-2025-000000063
Issued by
Cobb County, Georgia

About this file

This document is a submittal cover sheet and product data sheets for a weather-resistive barrier submitted by F.H. Paschen for the Kennesaw State University (KSU) Clendenin Building Envelope Repairs project. The submittal is for Henry Jumbo Tex Weather-Resistive Barrier, which is part of a moisture control system designed for use behind fiber cement siding, residential stucco, vinyl, and wood siding. The product is intended to guard against internal wall damage caused by water intrusion and moisture condensation, providing optimal breathability and water protection. The submittal was dated 7/19/24 and reviewed by RJ Wells Epsten Group on 7/24/2024, with specific comments noting that the product is part of a larger stucco assembly and requires compatible components.

The product data sheets detail the technical specifications of the Henry Jumbo Tex Weather-Resistive Barrier, highlighting its performance characteristics such as water vapor transmission, water resistance, and tensile strength. The barrier meets multiple industry standards, including ASTM specifications and International Building Code requirements. The accompanying PAC-CLAD product data sheet provides additional technical information about flashing and sheet metal components, noting availability in various colors, finishes, and materials. The submittal includes a 15-year material and labor warranty, emphasizing the product's durability and the manufacturer's confidence in its performance for building envelope applications.

View the file

Other files

File Type Posted
042000_06_00 Anchor Plates Submittal_EGI.pdf PDF
092423_04_00 Corner Bead Submittal_EGI.pdf PDF
092423_02_00 Control Joint Submittal_EGI.pdf PDF
092400_05_00 Mesh Lath Submittal_EGI.pdf PDF
Clendenin _ Structural Assessment Report_EGI.pdf PDF
071300_01_00 Waterproof Membrane _ Barrier Su.pdf PDF
RFQ for Select Bid Process Clendenin Final.doc DOC document
072100_01_00 Basecoat _ Adhesive Submittal_EG.pdf PDF
072726_01_00 Fluid Applied Permeable Membrane.pdf PDF
Clendenin Enclosure Investigative Report_23_0.pdf PDF
Clendenin Building _ Structural Assessment Re.pdf PDF
092423_05_00 Stucco Assembly Submittal_EGI.pdf PDF
Daily Field Report_24_11_05_Shear Review.pdf PDF
042000_01_00 Brick Ties Submittal_EGI.pdf PDF
Sign_in Sheet 04_08_2025.pdf PDF
042000_05_00 Multipurpose Sealant Submittal_E.pdf PDF
STUCCO COLOR PALETTE_IMG_3261.jpeg JPEG file
042000_02_00 Self Adhering Flashing Submittal.pdf PDF
Parex Stucco Systems.pdf PDF
Existing Clendenin Arch_Struc Drawings.pdf PDF
Addendum 002_RFQ_275_25_252_.docx DOCX document
Addendum 001_RFQ_275_25_252.docx DOCX document
Addendum 003_RFQ_275_25_252_Epsten rev KM.pdf PDF
Clendenin Bulletin 2_Combined Set.pdf PDF
092423_03_00 Casing Bead Submittal_EGI (Rev1).pdf PDF
092423_01_00 Preblended Stucco Submittal_EGI.pdf PDF
042000_03 Weep Holes Submittal_EGI.pdf PDF
042000_04_00 Termination Bar Submittal_EGI.pdf PDF
Clendenin _NWS_ Bid Form.doc DOC document
Instructions to Bidders_Clendenin NWS.docx DOCX document
076200_01_00 Flashing _ Joint Filler Submitta.pdf PDF
Clendenin NWS _Suppl Cond State Rev 081924.doc DOC document
Clendenin _ Field Observation Report.pdf PDF
099113_01_00 Acrylic Finish Submittal_EGI.pdf PDF
RFQ for Select Bid Process Clendenin Final.doc DOC document
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F.H. PASCHEN, S.N. NIELSEN & ASSOCIATES LLC

1344 La France Street, NE Suite 2, Atlanta, GA 30307

p. 404.942.1307 f. 404.228.4050 | www.fhpaschen.com

SUBMITTAL COVER SHEET

Fill out items 1 through 4 below and submit product data sheet, sample, shop drawing, or other items submitted to the Owner/Architect/Engineer. Each submittal line item shall have its own Submittal Cover Sheet.

Project Name: KSU Clendenin Building Envelope Repairs Contractor: FH Paschen

Project Manager: Justice Hill

Address:

739 Trabert Ave NW Atlanta, GA 30318

Phone: 770-584-4267

Architect/Engineer: RJ Wells Epsten Group Owner: Kennesaw State University

Owner Project Manager:

Emmanuel Bertrand - KSU

1. Date: ______7/19/24 _____

2. Submitted Item: ________Weather-Resistive Barrier

3. Manufacturer: ____Henry___

4. Notes:

Owner/ Engineer/ Architect Stamp

No exception taken.

Revise as noted. Do not resubmit. See Notes above.

Revise as noted. Resubmit. See Notes above.

Rejected. See Notes above.

Checking of submittals is only for general conformance with the design concept of the Project and general compliance with the information given in Contract Documents. Any action shown is subject to the requirements of the Drawings and Specifications. Contractor is responsible for dimensions to be confirmed and correlated at the job site, quantities, information that pertains solely to the fabrication processes or to techniques of construction, coordination of the work of all trades, and the satisfactory performance of his work.

By: Date:

REVIEWED NO

COMMENT

REVISE &

RESUBMIT

BY

SUBMITTAL#

DATE

SPEC

RJWells 7/24/2024

071300-02-00 071300 epstengroup 101 Marietta Street NW Suite 2600 Atlanta, Georgia 30303 t 404 577 0370 epstengroup.com

Disclaimer: Review is for systems commissioning only. Submittal acceptance or rejections above are recommendations only. Final approval is the responsibility of the Design Professional.

EGI General Comments

1. This product is part of a whole stucco assembly, the acceptance of this product is contingent on the use of other compatible AWRB and stucco components. Review comments on other stucco-related submittals prior to procurement.

2. Product substitutions are not accepted unless explicitly accepted in writing by the manufacturer.

3. PAC-CLAD product data belongs in a separate submittal under division 076200, revise and resubmit accordingly, also see comment directly below for resubmittal.

4. PAC-CLAD is an acceptable manufacturer, however, the submittal does not specify which metal type(s), gauge(s), finish(es), profile(s) and where the metal components to be located on the building. The Architectural drawing set includes several stainless steel flashing components part of the brick, window, and stucco repairs. Recommend stainless steel to be 20 gauge minimum. Please provide supplemental submittal providing missing information prior to procurement.