092400_05_00 Mesh Lath Submittal_EGI.pdf
PDF 454 KB Posted
- Solicitation number
- PE-54300-RFQC-2025-000000063
- Issued by
- Cobb County, Georgia
About this file
This is a Product Submittal Sheet for Diamond Mesh Lath by Clark Dietrich, submitted as part of the KSU Clendenin Building Envelope Repairs project for Kennesaw State University. The document details a galvanized, expanded steel plaster and stucco base material intended for use in interior and exterior plaster applications, including surfaces like ceilings, soffits, fascias, and ceramic tile installations. The submittal is specifically for mesh lath with two product variants: LAM 2.5 lbs. and LAM 3.4 lbs., both measuring 27" x 97" and packaged in bundles of 10 pieces, with 20 yards per bundle and 500 yards per pallet. The material is G60 galvanized steel and complies with multiple ASTM standards including A653, C841, C847, and C1063.
The product offers potential LEED v4.1 and v4 sustainability credits in categories such as Environmental Product Declarations, Sourcing of Raw Materials, Material Ingredients, and Construction and Demolition Waste Management. The submittal includes specific storage recommendations, noting that materials must be kept dry, stacked off the ground, and protected from weather and surface contamination. Limitations are noted, such as avoiding use with magnesium oxychloride cement stucco or Portland cement stucco containing calcium chloride additives. The document is part of a comprehensive submittal process for the Clendenin Building Envelope Repairs project, with technical review and recommendations provided by Epsten Group, the project's architectural and engineering firm.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F.H. PASCHEN, S.N. NIELSEN & ASSOCIATES LLC
1344 La France Street, NE Suite 2, Atlanta, GA 30307
p. 404.942.1307 f. 404.228.4050 | www.fhpaschen.com
SUBMITTAL COVER SHEET
Fill out items 1 through 4 below and submit product data sheet, sample, shop drawing, or other items submitted to the
Owner/Architect/Engineer. Each submittal line item shall have its own Submittal Cover Sheet.
Project Name: KSU Clendenin Building Envelope Repairs Contractor: FH Paschen
Project Manager: Justice Hill
Address:
739 Trabert Ave NW
Atlanta, GA 30318
Phone: 770-584-4267
Architect/Engineer: RJ Wells – Epsten Group Owner: Kennesaw State University
Owner Project
Manager:
Emmanuel Bertrand - KSU
1. Date: ______7/19/24 _____
2. Submitted Item: ________Mesh Lath
3. Manufacturer: ____Clark Dietrich___
4. Notes:
Contractor’s Stamp Owner/ Engineer/ Architect Stamp
No exception taken.
Revise as noted. Do not resubmit. See Notes above.
Revise as noted. Resubmit. See Notes above.
Rejected. See Notes above.
Checking of submittals is only for general conformance with the design concept of the Project and general compliance with the information given in Contract Documents. Any action shown is subject to the requirements of the Drawings and Specifications. Contractor is responsible for dimensions to be confirmed and correlated at the job site, quantities, information that pertains solely to the fabrication processes or to techniques of construction, coordination of the work of all trades, and the satisfactory performance of his work.
By: Date:
REVIEWED NO
COMMENT
REVISE &
RESUBMIT
BY
SUBMITTAL#
DATE
SPEC
RJWells 7/24/2024
092400-05-00 092400 epstengroup 101 Marietta Street NW Suite 2600 Atlanta, Georgia 30303 t 404 577 0370 epstengroup.com
Disclaimer: Review is for systems commissioning only. Submittal acceptance or rejections above are recommendations only. Final approval is the responsibility of the Design Professional.
EGI General Comments
1. This product is part of a whole stucco assembly, the acceptance of this product is contingent on the use of other compatible AWRB and stucco components. Review comments on other stucco-related submittals prior to procurement.
2. Product substitutions are not accepted unless explicitly accepted in writing by the manufacturer.
3. Fasteners must be compatible with the mesh lath and stucco assembly. Fasteners must engage with backup wall framing and spaced according to written manufacturer instructions. If the backup wall construction (sheathing, framing, etc.) exhibits deficiencies, notify the Architect and stucco manufacturer for review.
4. Suggest updating submittal number to "092423-05-00" (preferred) or "092400-01-00".
Diamond Mesh Lath Galvanized, expanded steel plaster and stucco base
A superior, multi-purpose expanded steel substrate for Portland cement or widely used for interior and exterior gypsum plaster and stucco & stone reinforcement. Applications include ceilings, soffits, and fascia surfaces, and under ceramic tile in wall, ceiling, and floor applications. Metal lath is useful in general purpose applications and is the best lath available for ornamental work and for flat or contoured surfaces as well as for use as a reinforcing underlay for spray-applied fireproofing.
Expanded metal lath is formed from sheet steel that has been slit and expanded to form hundreds of
“keys” per square yard. It is proven over time to possess exceptional strength and flexibility, making it the preferred metal base requested by contractors and design professionals.
2.5# and 3.4# metal lath are available in G90 coating with a special order and lead time. Diamond metal lath are also available with a 60-Minute Grade-D asphalt paper-backing (APB) weather resistant barrier.
Product Data & Ordering Information:
Material: G60 Galvanized Steel
Packaged: 25 bundles or 250 pieces per pallet
Product Code Wt. per Sq. Yd. Sheet Size Pcs./Bdl. Yds./Bdl. Yds./Pallet
LAM 2.5 lbs. 27" x 97" 10 20 500
LAM 3.4 lbs. 27" x 97" 10 20 500
Code Approvals & Performance Standards
ASTM A653 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy- Coated (Galvannealed) by the Hot-Dip Process ASTM C841 Standard Specification for Installation of Interior Lathing and Furring ASTM C847 Standard Specification for Metal Lath ASTM C1063 Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster Intertek CCRR-0204 Metal Lath - Code Compliance Research Report SDS For ASTM A653 Steel Finishing Products For Interior Finishing and Exterior Finishing
Storage:
All stored materials shall be kept dry. Materials shall be stacked off the ground, supported on a level platform, and protected from the weather and surface contamination per ASTM C847 & C1063.
Limitations:
Galvanized steel products should not be used with magnesium oxychloride cement stucco or Portland cement stucco containing calcium chloride additives. Flat lath must be furred on solid surfaces that receive stucco.
Sustainability Credits For more details and LEED letters contact Technical Services at 888-437-3244 or visit clarkdietrich.com/LEED.
LEED v4.1 MR Credit: Environmental Product Declarations: EPD (1 point) - Sourcing of Raw Materials (up to 2 points) - Material Ingredients (1 point) - Construction and Demolition Waste Management (up to 2 points)
LEED v4 MR Credit: Building Product Disclosure and Optimization: EPD (1 point) - Sourcing of Raw Materials (1 point) - Material Ingredients (1 point) - Construction and Demolition Waste Management (up to 2 points) - Innovation Credit (up to 2 points).
Product Submittal Sheet Technical Services: 888-437-3244, Engineering Services: 877-832-3206, Sales 800-543-7140
Stone Veneer, Stucco 09.22.36 (Metal Lath)
Diamond Mesh Lath The technical content of this literature is effective 10/04/23 and supersedes all previous information.
https://www.astm.org/catalogsearch/result/?q=a653 https://www.astm.org/catalogsearch/result/?q=c841 https://www.astm.org/catalogsearch/result/?q=c847 https://www.astm.org/catalogsearch/result/?q=c1063 https://specdirect.intertek.com/controls/SDDocumentViewer.aspx?ccrr=CCRR-0204 https://www.clarkdietrich.com/sites/default/files/media/documents/CD_SDS-Steel_A653.pdf https://www.clarkdietrich.com/LEED https://www.clarkdietrich.com https://www.clarkdietrich.com/node/153
| Mesh Lath Cover Sheet |
| Mesh Lath Submittal |
| EIFS Submittal Cover Sheet |
| Stucco Submittal Package 07172024 |
File details come from the government source that posted it. Updated .