The document is a technical data sheet for Tremco's ExoAir® 230, a fluid-applied synthetic air and vapor permeable membrane, submitted as part of the KSU Clendenin Building Envelope Repairs project by F.H. Paschen. The submittal cover sheet, dated 9/27/24, is for a Fluid Applied Permeable Membrane manufactured by Tremco, specifically intended for the Kennesaw State University project. The technical data sheet provides comprehensive details about the membrane's characteristics, including its application methods, coverage rates, and physical properties.
The ExoAir® 230 membrane is designed for exterior wall applications, offering features such as UV stability, seamless installation, and the ability to mitigate air infiltration while allowing water vapor transmission. The product is compatible with various substrates including exterior sheathing, concrete block, and insulated concrete forms. It meets multiple industry standards, including ASTM and NFPA 285 fire resistance tests, and can be applied by spray or roller with specific thickness requirements. The membrane comes in standard colors (black and limestone) with custom color options available, packaged in 5-gallon pails and 52-gallon drums, and has a one-year shelf life when stored properly between 40-100°F.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F.H. PASCHEN, S.N. NIELSEN & ASSOCIATES LLC
1344 La France Street, NE Suite 2, Atlanta, GA 30307
p. 404.942.1307 f. 404.228.4050 | www.fhpaschen.com
SUBMITTAL COVER SHEET
Fill out items 1 through 4 below and submit product data sheet, sample, shop drawing, or other items submitted to the Owner/Architect/Engineer. Each submittal line item shall have its own Submittal Cover Sheet.
Project Name: KSU Clendenin Building Envelope Repairs Contractor: FH Paschen
Project Manager: Justice Hill
Address:
739 Trabert Ave NW Atlanta, GA 30318
Phone: 770-584-4267
Architect/Engineer: RJ Wells – Epsten Group Owner: Kennesaw State University
Owner Project Manager:
Emmanuel Bertrand - KSU
1. Date: ______9/27/24 _____
2. Submitted Item: ________Fluid Applied Permeable Membrane
3. Manufacturer: ____Tremco___
4. Notes: _____
Contractor’s Stamp Owner/ Engineer/ Architect Stamp
No exception taken.
Revise as noted. Do not resubmit. See Notes above.
Revise as noted. Resubmit. See Notes above.
Rejected. See Notes above.
Checking of submittals is only for general conformance with the design concept of the Project and general compliance with the information given in Contract Documents. Any action shown is subject to the requirements of the Drawings and Specifications. Contractor is responsible for dimensions to be confirmed and correlated at the job site, quantities, information that pertains solely to the fabrication processes or to techniques of construction, coordination of the work of all trades, and the satisfactory performance of his work.
By: Date:
APPROVED
APPROVED AS CORRECTED
REVISE AND RESUBMIT
REJECTED
Fabrication / Installation may be undertaken. Approval does not authorize changes to the Contract Sum or Contract Time.
Fabrication and/or Installation MAY NOT be undertaken. In resubmitting, limit corrections to items marked.
NO PRIOR APPROVAL STAMP
BY CONTRACTOR
NOT A REQUIRED SUBMITTAL
ACTION AS NOTED BELOW
Review / approval neither extends nor alters contractual obligations of the Architect or Contractor.
The Epsten Group, Inc.
DATE REVIEWER
X
09/30/24 Olu Oshinubi, VP / Arch
09/30/24Olu Oshinubi, VP / Arch
X
ExoAir® 230 Fluid-Applied, Synthetic Air and Vapor
Permeable Membrane
PRODUCT DESCRIPTION
ExoAir® 230 Fluid-Applied Synthetic Permeable Air Barrier Membrane is a monolithic, elastomeric membrane designed to be rolled or sprayed onto exterior above-grade wall assemblies to mitigate air infiltration/exfiltration and water penetration while remaining permeable to the passage of water vapor. It may also be used as a liquid-applied flashing, enabling the contractor to address both the membrane and flashing needs with a single material.
BASIC USES
ExoAir 230 is typically applied to exterior sheathing panels, concrete block, poured concrete, wood substrates, Nudura Insulated Concrete Forms (ICF), or insulated concrete forms, as an air and vapor permeable membrane. ExoAir 230 can be used with ExoAir 110, ExoAir 110AT, ExoAir 230 (and mesh) or Dymonic® 100 as liquid applied flashing to detail into the rough opening.
FEATURES & BENEFITS
• ExoAir 230 is a UV stable, seamless, monolithic membrane that creates a fully adhered air barrier when properly installed.
• The ability to roller or spray apply the material affords the contractor the ability to accelerate installation times compared to traditional self-adhered membrane systems.
• The high-performance properties of the ExoAir 230 membrane retard the migration of air and bulk water but allow water vapor to pass through the membrane. As a result, vapor permeable systems like ExoAir 230 allow for more flexibility in the placement of the air barrier membrane in the wall design.
• ExoAir 230 is formulated for UV resistance providing the flexibility to install rainscreen systems with open joints or to allow the membrane to be exposed longer during the construction process.
• ExoAir 230 can be custom colored to meet all of your design needs.
• ExoAir 230 is specifically formulated for design options requiring assemblies that have been evaluated for NFPA 285.
• ExoAir 230 is an approved Water Resistive Barrier when applied to Nudura Insulated Concrete Forms (ICF), or insulated concrete forms.
AVAILABILITY
ExoAir 230 is immediately available from your local Tremco Sales Representative or Distributor. For Distributor locations, visit www.tremcosealants.com
COVERAGE RATES
Exterior Sheathing or Insulated Concrete Forms: Minimum 48 wet mils (25 dry mils); 33 ft²/gal (3.07 M²/US gal)
Porous Substrates: Minimum 70 wet mils (35 dry mils); 23 ft²/gal (2.13 M²/US gal)
Note: Above listed coverage rates are minimums, installing at a greater thickness is acceptable. For more information, please contact your Tremco Representative
PACKAGING
5-gal (19-L) pails 52-gal (197-L) drums
Tremco Commercial Sealants & Waterproofing | tremcosealants.com 1120/EA230DS
3735 Green Rd Beachwood OH 44122
216.292.5000 / 800.321.7906
1451 Jacobson Ave Ashland OH 44805
419.289.2050 / 800.321.6357
220 Wicksteed Ave Toronto ON M4H1G7
416.421.3300 / 800.363.3213
1350 Gay-Lussac, Unit: 3 Boucherville QC J4B 7G4 514.521.9555
COLORS
Standard color: Black & Limestone; Custom colors available upon request.
STORAGE
Store ExoAir 230 in original, undamaged packages in a clean, dry, protected location with temperatures 40 to 100 °F (5 to 37 °C).
SHELF LIFE
1 year when stored in accordance with storage instructions
APPLICABLE STANDARDS
ExoAir 230 has been tested to the following industry standards for air barriers:
• AATCC 127-2008 Water Resistance: Hydrostatic Pressure Test
• ASTM C1305 Standard Test Method for Crack Bridging Ability of Liquid-Applied Waterproofing Membrane
• ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers – Tension
• ASTM D1970 Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing
Underlayment for Ice Dam Protection
• ASTM D4541 Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers
• ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
• ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by
Uniform Static Air Pressure Difference
• ASTM E2178 Standard Test Method for Air Permeance of Building Materials
• ASTM E2357 Standard Test Methods for Determining Air Leakage of Air Barrier Assemblies
• NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall
Assemblies Containing Combustible Components
FIRE RATED SYSTEMS
ExoAir 230 has been tested in assemblies according to NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components. All of the NFPA 285 UL listed assemblies using Tremco materials can be found using the technical bulletin: ASHRA 90.1 & NFPA 285: Defining & Specifying to Meet IECC & IBC or utilizing the following link: http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=FWFX.R27656&ccnshorttitle=Exterior+Wall+System+Components&objid=1 082999775&cfgid=1073741824&version=versionless&parent_id=1082761881&sequence=1.
For NFPA 285 engineering judgment requests please go to www.tremcosealants.com/NFPA 285 Engineering Judgment Request or contact Tremco Technical Service at 866-209-2404.
LIMITATIONS
• No more than 12 months of UV exposure before façade installation. If membrane is exposed for a period exceeding 12 months, contact Tremco Technical Service for additional recommendations at 866-209-2404, or visit the Technical Resources area of our website at www.tremcosealants.com and "Ask the Expert."
• Do not apply to damp, contaminated or frost-covered surfaces.
• Not to be used as a permanently exposed surface. Contact your local Tremco Sales Representative for project specific requirements.
• Membrane shall be protected from rain and washout prior to drying.
• When applying to surfaces below 40 °F (5 °C), please refer to the Technical Bulletin- Cold Temperature Recommendations for
Air Barrier Applications at www.tremcosealants.com or contact Tremco Technical Service at 886-209-2404.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=FWFX.R27656&ccnshorttitle=Exterior+Wall+System+Components&objid=1082999775&cfgid=1073741824&version=versionless&parent_id=1082761881&sequence=1 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=FWFX.R27656&ccnshorttitle=Exterior+Wall+System+Components&objid=1082999775&cfgid=1073741824&version=versionless&parent_id=1082761881&sequence=1 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=FWFX.R27656&ccnshorttitle=Exterior+Wall+System+Components&objid=1082999775&cfgid=1073741824&version=versionless&parent_id=1082761881&sequence=1
Beachwood OH 44122
216.292.5000 / 800.321.7906
1451 Jacobson Ave Ashland OH 44805
419.289.2050 / 800.321.6357
220 Wicksteed Ave Toronto ON M4H1G7
416.421.3300 / 800.363.3213
1350 Gay-Lussac, Unit: 3
• ExoAir 230 is not to be applied directly to fireproofing materials. Contact Tremco Technical Service at www.tremcosealants.com for alternative recommendations.
• Keep product from freezing prior to being applied to the substrate. It is best to store ExoAir 230 off the floor at an ambient temperature above 40 °F (10 °C).
WARRANTY
Tremco warrants its Products to be free of defects in materials but makes no warranty as to appearance or color. Since methods of application and on-site conditions are beyond our control and can affect performance, Tremco makes no other warranty, expressed or implied, including warranties of MERCHANTABILITY and FITNESS FOR A PARTICULAR PURPOSE with respect to Tremco Products.
Tremco’s sole obligation shall be, at its option, to replace or to refund the purchase price of the quantity of Tremco Products proven to be defective, and Tremco shall not be liable for any loss or damage.
Beachwood OH 44122
216.292.5000 / 800.321.7906
1451 Jacobson Ave Ashland OH 44805
419.289.2050 / 800.321.6357
220 Wicksteed Ave Toronto ON M4H1G7
416.421.3300 / 800.363.3213
1350 Gay-Lussac, Unit: 3
*All product testing performed at 35 dry mils.
TYPICAL PHYSICAL PROPERTIES
PROPERTY DESCRIPTION
TYPE Synthetic Acrylic
COLOR Limestone; Custom colors available upon request
SOLIDS 0.53
APPLICATION Spray/Roller
THICKNESS Exterior Sheathing: Minimum 48 mils (wet), 25 mils (dry); Porous Substrates: Minimum 70 mils (wet), 35 mils (dry)
STORAGE TEMPERATURE 40 to 100 °F (5 to 37 °C)
CURE TIME 16 to 24 hr at 75 °F (24 °C), 50% RH
APPLICATION TEMPERATURE Above 40 °F (5 °C) and rising. If installing below 40 °F (5 °C), please refer to Cold Weather Air Barrier Installation Technical Bulletin or contact Tremco Technical Service at 866-209- 2404.
SERVICE TEMPERATURE Intermittent Exposure up to 240 °F (115 °C)
PROPERTY TEST METHOD TYPICAL RESULTS
MAXIMUM V.O.C. Method 310 18 g/L
HYDROSTATIC HEAD AATCC – 127 Pass (5 hours)
CRACK BRIDGING ASTM C1305 Pass
ELONGATION
TENSILE STRENGTH ASTM D412 Die C
900% 121 psi
WATER IMMERSION ASTM D870 Pass
PLIABILITY, 180°, 1" (25 MM) MANDREL
(LOW TEMPERATURE FLEX)
NAIL SEALABILITY
ASTM D1970 – Section 7.6
ASTM D1970 – Section 7.9
Pass
Pass
ADHESION ASTM D4541 Concrete: 38 psi Exterior Sheathing: 20 psi
ANTIFUNGAL ASTM D5590 Pass
FLAME SPREAD
SMOKE DEVELOPMENT
E84
WATER VAPOR PERMEANCE
ASTM E96 Dry Cup ASTM E96 Wet Cup
1.44 US Perms
11.71 US Perms
WATER PENETRATION ASTM E331
Passed at 15 lb/ft² (718 Pa);
Passed at 6.27 lb/ft² (300 Pa) for 2 hours
AIR LEAKAGE OF MATERIAL
ASTM E2178; Free Film Method @ 75 Pa ASTM E2178; Free Film Method @ 300 Pa
0.00158 cfm/ft² (0.00805 L/(s•m²))
0.00435 cfm/ft² (0.02211 L/(s•m²))
AIR LEAKAGE OF ASSEMBLY ASTM E2357 0.003 cfm/ft² @ 1.56 lb/ft² (0.013 L/(s•m²) @ (75 Pa))
FIRE RESISTANCE OF ASSEMBLY NFPA 285 Pass