Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION
NO.
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.
IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
NSN 7540-01-152-8070
Previous edition unusable
00005
John Chaney
YELL 189105 - Mammoth Hotel Seismic Stabilization Phase 1 Yellowstone National Park, Wyoming
The purpose of this amendment is to correct specifications and drawings and answer questions received. See attached.
Proposal due date remains 19 August 2016 at 16:00 MT.
NPS, DSC Contracting Services Div 12795 W Alameda Pkwy P.O. Box 25287 Denver CO 80225-0287
P16PS00611
YELL 189105
1 7
08/15/2016
06/30/2016
Solicitation P16PS00611 Amendment Five
In order to correct specifications and drawing sheets and answer questions received, the above numbered solicitation is hereby amended as follows:
1. The following changes have been made to the project specifications.
a. Section 093013 2.2.C – Replace subsection in its entirety as indicated below:
C. Ceramic Floor Tile (Floor Tile 1, Floor Tile 2, Floor Tile 3, Floor Tile 4, Floor Tile 5, Floor Tile 6, Floor Tile 7, Floor Tile 8, Floor Tile 9): Provide tile by manufacturer and type listed or approved equal. Proposed equal will be evaluated based on the visual and technical characteristics indicated. Proposed equal shall match in-kind the indicated tile in all characteristics to be accepted.
1. Manufacturer: American Olean
2. Style: Unglazed Mosaics Colorbody Porcelain Tile
3. Body: Solid color porcelain
4. Absorption: Less than ASTM C 373 0.5% average
5. Breaking Strength: Greater than 300 lb
6. Coefficient of Friction: DCOF AcuTest minimum 0.42 or better.
7. Chemical Resistance: Chemical Resistant
8. Abrasion Resistance: Minimum 7 MOH’s scale.
9. Size & Shape:
a. Floor Tile - 1: 2x4 Field Tile: Ice White
b. Floor Tile - 2: 2x4 Field Tile: Artichoke
c. Floor Tile - 3: 1x2 Tile: Ice White
d. Floor Tile - 4: 1x2 Tile: Artichoke
e. Floor Tile - 5: 1x2 Tile: Dill Pickle
f. Floor Tile - 6: 2x2 Tile: Ice White
g. Floor Tile - 7: 2x2 Tile: Artichoke
h. Floor Tile - 8: 1x1 Tile: Dill Pickle
i. Floor Tile - 9: 1x1 Tile: Ice White
b. Section 099123 3.4; Add new subsection “A General” before existing subsection “A Steel Substrates” and renumber all subsections following accordingly.
Subsection “A General” shall read as follows:
A. General: Contractor shall attend field conference with Contracting Officer to determine final interior color selections for each new painted room and/or element within the project based on the following schedule; elements indicated to match existing shall not accrue against the schedule. Conference shall occur prior to submission of product data, samples, or other action submittals for interior painting:
1. Painted Gypsum Walls:
a. Full Project: Up-to 7 unique colors within the project
b. Each Room: Up-to 3 unique colors within each room.
2. Painted Gypsum Ceilings:
a. Full Project: Up-to 3 unique colors within the project
b. Each Room: Up-to 2 unique colors within each room.
3. Painted Wood Trims:
a. Full Project: Up-to 3 unique colors within the project.
b. Each Room: Up-to 2 unique colors within each room.
4. Painted Wood Doors:
a. Full Project: Up-to 3 unique colors within the project.
b. Each Element: Up-to 2 unique colors.
5. Painted Wood Windows:
a. Full Project: Up-to 3 unique colors within the project.
b. Each Element: Up-to 2 unique colors.
6. Painted Metal:
a. Full Project: Up-to 4 unique colors within the project
b. Each Element: Up-to 2 unique colors.
c. Section 230900; replace BMS responsibility table with table below.
BMS RESPONSIBILITY MATRIX
WORK
FURNISH INSTALL Low Volt.
WIRING/TUBE
LINE POWER
BMS low voltage and communication wiring BMS BMS BMS N/A BMS conduits and raceway BMS BMS BMS BMS
Automatic dampers BMS 23 N/A N/A Manual valves 23 23 N/A N/A
Automatic valves BMS 23 BMS N/A Pipe insertion devices and taps including thermowells, flow and pressure stations.
BMS 23 BMS BMS
BMS Current Switches. BMS BMS BMS N/A BMS Control Relays BMS BMS BMS N/A
Fire Alarm smoke control relay interlock wiring / Fire Alarm shutdown relay interlock wiring
26 / 26 26 / 26 BMS / 26 26 / 26
Starters, HOA switches 26 / 23 26 / 23 N/A / 26 26 / 26 Control damper actuators BMS / 23 BMS / 23 BMS / 26 26 / 26
Starters, HOA switches 26 26 N/A 26 Control damper actuators BMS BMS BMS 26
2. The following changes have been made to the project drawings (See attachment sheets ASK 007 – ASK 011, SSK-12, and AF2.2):
a. Sheet A2.1 Detail 11; Modify stair configuration at north Lobby 162 & Vestibule 168 per detail 16/ASK.009. Coordinate changes through construction set.
b. Sheet A2.2 Keynote 6; Change to read “Provide new custom metal guardrail to match similar historic map rail at room 161. Provide 2 cross pair uprights modified with horizontal 1/8” metal bars not allowing the passage of a 4” sphere.
Provide handrail sim detail 9/A8.3 at stair with modified bracket.”
c. Sheet A2.2 Keynote 12; Change to read “Provide and install new custom Mahogany handrail – see detail 9/A8.3 – run continuous with minimum joints possible.”
d. Sheet AF2.1; Add detail callout encompassing rooms 165, 166, and area of Lobby 162 noted as tile finish and reference to detail 6/ASK.011 attached to this addendum.
e. Sheet AF2.1; Add detail callout encompassing the NIC bar area of Map Room 161 and reference to detail 16/ASK.010 attached to this addendum. Tile finishes within the bar area are NIC and will be completed at a later date. Base bid is wood flooring to match Map Room 161 finish callout.
f. Sheet AF2.2; Delete sheet and replace with sheet AF2.2 attached to this addendum.
g. Sheet A6.1 Detail 13; Change note at existing historic drinking fountain to read “Clean and restore existing historic drinking fountain. Provide new bubbler and controls. Coordinate reinstallation at new location.”
h. Sheet A8.1 Detail 11; Add note to guardrail reading “Provide vertical supports at guardrail/handrail per detail 11/A8.3 evenly spaced within runs no greater than 4’-0” O.C. – Typical.”
i. Sheet A8.3 Detail 10; Delete detail in its entirety and replace with detail 9/ASK.009 attached.
j. Sheet A8.3 Detail 9; Add detail 18/ASK.009 attached at position 9 this sheet.
k. Sheet A9.1 Detail 1; Delete detail and replace with detail 6/ASK.007 attached to this addendum.
l. Sheet A9.1 Detail 3; Delete detail and replace with detail 16/ASK.007 attached to this addendum.
m. Sheet A9.1 Detail 6; Delete detail and replace with detail 6/ASK.008 attached to this addendum.
n. Sheet A9.1 Detail 11; Replace detail with general note indicated on ASK.008 attached to this addendum.
o. Sheet A9.12 Detail 1; Delete detail and replace with detail 14 & 19 / ASK.010 attached to this addendum.
p. Sheet A9.12 Detail 6; Delete detail and replace with detail 9/ASK.010 attached to this addendum.
q. Sheet A9.12 Detail 7; Delete detail and replace with details 5, 10, 16 & 18 /
ASK.011 attached to this addendum.
r. Sheet M3.0 Detail 1; Add new keynote 12 at FC-9.
s. Sheet M3.0 Keynote Legend; Add Keynote 12 reading “Route 1” condensate drain piping from FC-9 to nearest floor sink – Field coordinate exact routing with Contracting Officer.”
t. Sheet E1.2; Change circuit 1B-22,24 to be comprised of (2) 20A, 1-pole devices.
u. Sheet E2.1; Delete circuit 1B-22,24 serving equipment 29. Circuit breakers shall be installed as indicated below:
1) Change circuit serving equipment item 29 (Walk in Cooler evaporator) to be connect to circuit 1B-22. This is a single phase 120V power connection.
2) Add power connection to serve equipment item 29 (Walk in Cooler) door heater and lights. Power connection is located on the top of the walk in cooler near door end. Source power for doors and lights from circuit 1B- 24.
3) Provide circuit consisting of 3) #8 + 1)#10 Gnd in 3/4” C for power connection serving equipment noted by work note #11 in Bar 161A, circuit 1B-21,23.
v. Sheet E2.2; Provide circuit consisting of #10’s in 3/4” C for power connection serving equipment 29.1 (Circuit 2A-7,9).
3. The following technical questions and their individual answers are provided:
Q56r1. Is the existing clear finish on woodwork varnish or lacquer?
A56r1. It is assumed the existing clear wood finish is a varnish.
Q64. In section 230900 BMS Matrix the legend notes to see note 1 & 2 below, no notes apparent.
A64. No notes are required. Reference changes to section 230900 referenced in this amendment.
Q65. In section 230900 BMC Matrix notes line power to VAV Boxes, it is not apparent the power requirement in the E drawings, panel schedules or on the mechanical drawings.
A65. Reference changes made to BMC Matrix referenced in this amendment.
Q66. Drawing No. FS3.0, Foodservice Electrical Schedule – First Floor, Item No.
29.1, Cooler Condensing Unit calls for single phase power. Drawing FS7.0, Refrigeration Notes, Heatcraft air cooled condensing unit calls for three phase power. Which phase is it to be?
A66. Single phase power will be required upon installation of KEC by others at a later date.
Q67. Specification Section 114000 – Foodservice Equipment, Section 2.1.FF – Item 29.2 states “temperature tracking software and temperature data loggers for walk in cooler; See FS 7.1 Detail 7”. FS 7.1, Detail 7 shows a wiring diagram for “Walk In Control & Monitor Each Instance” as well as “Stand Along Refrig.
Monitor Per Each Instance”. Please clarify if stand alone refrigerators, Items 209, 211 and 212 are to be a part of the Weiss temperature tracking software and temperature data loggers.
A67. Kitchen equipment is Not in Contract and will be provided by others at a later date.
Q68. Drawing No. FS7.0, Refrigeration Notes, Climate Control low profile evaporator is stated to include a mounted thermostat via the walk‐in manufacturer. It is our understanding that Item 29.2 – Controlling & Monitoring Gateway replaces the thermostat controls provided by the walk‐in manufacturer.
Please clarify how the walk‐in will be controlled.
A68. Kitchen equipment is Not in Contract and will be provided by others at a later date.
Q69. Drawing No. FS7.0, Doors Notes, lists a single pole toggle switch w/ pilot light @ ext. It is our understanding that Item 29.2 – Controlling & Monitoring Gateway replaces the standard lighting controls with its own keypad. Please clarify how the walk‐in lighting will be controlled.
A69. Kitchen equipment is Not in Contract and will be provided by others at a later date.
Q70. Reference Drawing No. FS7.1, Detail 7 and Specification Section 114000 – Foodservice Equipment, Section 2.1.FF – Item 29.2. It is our understanding that the Electrical Contractor is to provide wiring and terminate all connections to the Weiss Instruments Control System as shown on Detail 7. Please confirm.
A70. Kitchen equipment is Not in Contract and will be provided by others at a later date.
Q71. Reference Drawing No. FS3.0, Drawing No. FS7.1, Detail 7 and Specification Section 114000 – Foodservice Equipment, Section 2.1.FF – Item
29.2. It is our understanding that the Weiss Instruments Control System requires communication wiring from the location of the XW60K, typically located atop the walk‐in box, to the Web X location, typically located near a desk and/or computer. It is not clear from FS3.0 where this location is to be. Please clarify.
A71. Kitchen equipment is Not in Contract and will be provided by others at a later date.
Q72. Reference Specification Section 114000 – Foodservice Equipment, Section 2.1.FF – Item 29.2. Weiss Instruments offers two models of its XWEB KIT Control & Monitoring Gateway; XWEB300D and XWEB500D. Which model is desired for this project?
A72. Kitchen equipment is Not in Contract and will be provided by others at a later date.
Q73. Detail 18 on Sheet S5.1 appears to have several errors. This detail shows new floor sheathing on top of the existing diagonal sheathing on the first floor. It refers to detail 7 on sheet S5.3 which is a generic sheathing pattern for floors and roofs. The implication is that there is a new subfloor across the entire first floor which would put the first riser of the circular stair out of compliance with code.
Please clarify.
A73. It is the intention that at the first floor existing diagonal sheathing supplementary attachment occurs without the addition of new sheathing. New sheathing will be required at new addition areas of the first floor. Replace detail 18/S5.1 with detail 18/SSK-12 attached.
4. All other terms and conditions remain unchanged.
| SF 30 rev.pdf |
| Amendment5 text |
| C. Ceramic Floor Tile (Floor Tile 1, Floor Tile 2, Floor Tile 3, Floor Tile 4, Floor Tile 5, Floor Tile 6, Floor Tile 7, Floor Tile 8, Floor Tile 9): Provide tile by manufacturer and type listed or approved equal. Proposed equal will be evaluated ba... |
| 1. Manufacturer: American Olean |
| 2. Style: Unglazed Mosaics Colorbody Porcelain Tile |
| 3. Body: Solid color porcelain |
| 4. Absorption: Less than ASTM C 373 0.5% average |
| 5. Breaking Strength: Greater than 300 lb |
| 6. Coefficient of Friction: DCOF AcuTest minimum 0.42 or better. |
| 7. Chemical Resistance: Chemical Resistant |
| 8. Abrasion Resistance: Minimum 7 MOH’s scale. |
| 9. Size & Shape: |
| a. Floor Tile - 1: 2x4 Field Tile: Ice White |
| b. Floor Tile - 2: 2x4 Field Tile: Artichoke |
| c. Floor Tile - 3: 1x2 Tile: Ice White |
| d. Floor Tile - 4: 1x2 Tile: Artichoke |
| e. Floor Tile - 5: 1x2 Tile: Dill Pickle |
| f. Floor Tile - 6: 2x2 Tile: Ice White |
| g. Floor Tile - 7: 2x2 Tile: Artichoke |
| h. Floor Tile - 8: 1x1 Tile: Dill Pickle |
| i. Floor Tile - 9: 1x1 Tile: Ice White |
| A. General: Contractor shall attend field conference with Contracting Officer to determine final interior color selections for each new painted room and/or element within the project based on the following schedule; elements indicated to match existi... |
| 1. Painted Gypsum Walls: |
| a. Full Project: Up-to 7 unique colors within the project |
| b. Each Room: Up-to 3 unique colors within each room. |
| 2. Painted Gypsum Ceilings: |
| a. Full Project: Up-to 3 unique colors within the project |
| b. Each Room: Up-to 2 unique colors within each room. |
| 3. Painted Wood Trims: |
| a. Full Project: Up-to 3 unique colors within the project. |
| b. Each Room: Up-to 2 unique colors within each room. |
| 4. Painted Wood Doors: |
| a. Full Project: Up-to 3 unique colors within the project. |
| b. Each Element: Up-to 2 unique colors. |
| 5. Painted Wood Windows: |
| a. Full Project: Up-to 3 unique colors within the project. |
| b. Each Element: Up-to 2 unique colors. |
| 6. Painted Metal: |
| a. Full Project: Up-to 4 unique colors within the project |
| b. Each Element: Up-to 2 unique colors. |