SHEET SHEET NAME
FS0.0 FS COVER PAGE
FS0.1 FS GENERAL NOTES
FS1.0 FS FLOOR PLAN - BAR
FS1.1 FS FLOOR PLAN - PANTRY
FS3.0 FS ELECTRICAL PLAN - BAR
FS3.1 FS ELECTRICAL PLAN - PANTY
FS4.0 FS PLUMBING PLAN - BAR
FS4.1 FS PLUMBING PLAN - PANTRY
FS5.0 FS DETAIL PAGE
FS6.0 FS BUILDING WORKS PLAN - BAR
FS6.1 FS BUILDING WORKS PLAN - PANTRY
FS7.0 FS WALK-IN DETAILS
FS7.1 FS WALK-IN DETAILS
N/A
N/A
YTEICOSSTNAT
LU
SN
OC
L A
N
OI
T A
N R E T
NI
E
CI
V R
E S
D O
O F
RE
BM
EMLANOISSEFORP
707871
MICHAEL MILES
MEASUREMENTS ON THIS PLAN HAVE BEEN ASSEMBLED BY H-C DESIGN & CONSULTING. HOWEVER NO RESPONSIBILITY FOR THE ACCURACY OF SUCH MEASUREMENTS WILL BE TAKEN BY H-C D&C. ALL UTILIZING THESE PLANS ARE RESPONSIBLE FOR VERIFYING ANY MEASUREMENTS OF THEIR CONCERN. ALL MECHANICAL INFORMATION IS FOR THE SOLE PURPOSE OF IDENTIFYING THE REQUIREMENTS OF THE FOODSERVICE EQUIPMENT AND IS IN NO WAY ENGINEERED BY H-C D&C. H-C DESIGN & CONSULTING ASSUMES NO RESPONSIBILITY FOR CHANGES DICTATED BY AS-BUILT CONDITIONS, EXISTING/ OWNER PROVIDED EQUIPMENT,LOCAL BUILDING CODES, STRUCTURAL CONDITIONS, HEALTH DEPARTMENT, ORDINANCES, AS WELL AS MODIFICATIONS TO THIS PLAN AND WORK PERFORMED BY CONTRACTORS. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING THE GENERAL NOTES AS PART OF THESE PLANS BEFORE WORK IS TO BEGIN. ANY ISSUES, DISCREPANCIES OR INCONSISTENCIES FOUND IN THESE PLANS AND OR WITH LOCAL CODES MUST IMMEDIATELY BE CALLED TO THE ATTENTION OF H-C D&C IN WRITING SO THE APPROPRIATE ACTION CAN BE TAKEN. THESE PLANS AND THEIR CONTENTS ARE THE PROPERTY OF H-C D&C AND MAY ONLY BE REPRODUCED WITH PERMISSION BY H-C DESIGN & CONSULTING.
A R C H I T E C T U R E I N T E R I O R S H I S T O R I C www.aearchitects.com
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 5 9 8 0 2 P H. 4 0 6 . 7 2 1 . 5 6 4 3 F A X. 4 0 6 . 7 2 1 . 1 8 8 7
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 5 9 1 0 1 P H. 4 0 6 . 2 4 8 . 2 6 3 3 F A X. 4 0 6 . 2 4 8 . 2 4 2 7
4 2 8 E A S T M E N D E N H A L L B O Z E M A N, M T 5 9 7 1 5 P H. 4 0 6 . 4 5 3 . 7 3 1 0
PROJECT NO.
NPS PROJ NO.
REVISIONS
DRAWING NO.
PKG
NO.
PKG1
PKG2
PKG3
SHEET
OF
DESIGNED:
CADD:
TECH REVIEW:
DATE
TITLE OF SHEETDRAWING NO.
0 1 2 3 4 5 6 7 8 9 10 inches
189105
/1
/2
:3
:2
P M
15021.00 06.10.2016
FS COVER PAGE
MAMMOTH HOTEL SEISMIC
STABILIZATION & REHABILITATION
PHASE I.
YELLOWSTONE NATIONAL PARK, WYOMING
MM
AMT
MM
06.10.2016
FS0.0
CO
N
ST
RU
C T
IO
N D
O
CU
M
EN
T S
NO. ROOM FLOOR BASE WALL CEILING
147A BAR AREA MOSAIC TILE FLOOR N/A TILE GYPSUM PAINTED
151 BAR BACK ROOM LINOLIUM SHEET FLOOR BY MANUFACTURER QUARRY TILE COVE GYPSUM PAINTED
235 JANITOR CLOSET LINOLIUM SHEET FLOOR N/A GYPSUM PAINTED GYPSUM PAINTED
234 PANTRY ROOM MOSAIC TILE FLOOR N/A GYPSUM PAINTED GYPSUM PAINTED
WALK-IN COOLER BY MANUFACTURER BY MANUFACTURER BY MANUFACTURER BY MANUFACTURER
HOOD SYSTEMS M.C. OR G.C. TO PROVIDE A N.S.F.AND U.L. LISTED HOOD
VENTILATION SYSTEM THAT WILL ADEQUATELY VENT COOKING EQUIPMENT AND
DISHWASHING EQUIPMENT
ITEM #
HVAC M.C. TO PROVIDE DUCTWORK AND ALL ASSOCIATED SYSTEMS TO COMPLETE
HOOD REQUIREMENTS
VECTOR CONTROL G.C. TO SEE THAT OPENINGS AT THE SIDE AND BASE OF ALL
EXTERIOR DOORS SHALL NOT EXCEED 1/4". ALL EXTERIOR WALL VENTS SHALL BE
PROPERLY SCREENED WITH 1/4" HARDWARE CLOTH SCREENING. ALL EXTERIOR WALL
PIPING AND OTHER OPENINGS SHALL BE TIGHTLY SEALED
GARBAGE AND TRASH G.C. TO PROVIDE ADEQUATE TRASH STORAGE
(DUMPSTER) AND AREA FOR CLEANING TRASH CONTAINERS. SEE ARCHITECTS SITE PLAN
FOR LOCATION
WINDOW AND DOORS G.C. TO PROVIDE MESH SCREENING ON ALL OPERABLE
WINDOWS. G.C. TO PROVIDE ALL ENTRANCE DOORS TO BE SELF CLOSING
DELIVERY DOORS G.C. TO PROVIDE ALL DELIVERY DOORS TO BE
SELF CLOSING. RECOMMENDED THAT THEY ALSO HAVE AN
EFFECTIVE OVERHEAD AIR CURTAIN OR FLY FAN
EMPLOYEE TOILET
______ SINGLE TOILET FOR EMPLOYEES
______ SEPARATE TOILET FOR MEN AND WOMEN EMPLOYEES
______ ROOM FOR DRESSING
______ LOCKERS
______ NOT IN CONTRACT
LIGHTING G.C. TO PROVIDE A MINIMUM OF 50-FOOT CANDLES OF LIGHT AT 30" ABOVE
THE FLOOR IN ALL COOKING, PREPARATION, GLASS & DISH WASHING AREAS. ALL LIGHT
FIXTURES MUST BE DESIGNED FOR CLEAN ABILITY AND PROTECTED AGAINST BREAKAGE
THROUGH THE USE OF PLASTIC SHIELDS, PLASTIC SLEEVES, SHATTERPROOF BULBS OR
OTHER APPROVED DEVICES
SCULLERY SINK FOR MULIT-USE EATING AND DRINKING
UTENSILS THAT WILL BE WASHED BY HAND. K.E.C. WILL PROVIDE A
THREE COMPARTMENT SINK WITH TWO DRAINBOARDS
ITEM #
FOOD SHIELDS K.E.C. TO PROVIDE N.S.F. APPROVED FOOD SHIELD OVER ALL
EXPOSED FOOD AT ANY CUSTOMER SERVICE COUNTER
ITEM #
DIP WELL K.E.C. TO PROVIDE N.S.F. APPROVED ICE CREAM DIPPING WELL WITH
WATER SUPPLY CLOSE TO THE ICE CREAM CABINET
ITEM #
VEGETABLE PREP SINK FOR FOOD PREPARATION. THE
K.E.C. WILL PROVIDE A ONE TO TWO COMPARTMENT SINK WITH ONE
DRAINBOARD
ITEM #
JANITORIAL SINK K.E.C. TO PROVIDE A SINGLE COMPARTMENT
MOP SINK WITH HOT AND COLD WATER FOR GENERAL CLEANING
ITEM #
HOT WATER HEATER G.C. AND/OR P.C. TO PROVIDE A HOT WATER HEATER THAT
WILL ADEQUATELY PROVIDE FOR THE FOOD SERVICE AND THE ENTIRE FACILITY.
SEE ARCHITECTURAL DRAWINGS
GARBAGE DISPOSAL AND COLLECTORS
______ 1. DISPOSAL IN THE THREE COMPARTMENT SINK
______ 2. DISPOSAL IN THE PRE RINSE SINK OF THE SOILED DISHTABLE
______ 3. DISPOSAL IN THE PREPARATION SINK
______ 4. COLLECTORS IN THE _______________________
FOODSERVICE CONSULTING FIRM
NAME: H-C DESIGN & CONSULTING
ADDRESS: 614 FERGUSON AVENUE, SUITE 1
BOZEMAN, MONTANA 59718
PHONE: 406-522-7700
SECTION 1: GENERAL INFORMATION
THESE FOOD SERVICE PLANS ARE FOR THE SOLE PURPOSE OF IDENTIFYING THE
LOCATION OF ; AND THE REQUIREMENTS FOR THE FOOD SERVICE EQUIPMENT ONLY.
THESE PLANS ARE NOT FOR GENERAL CONSTRUCTION. SEE ARCHITECTURAL PLANS
FOR ALL GENERAL CONSTRUCTION.
APPROXIMATE COMPLETION OF CONSTRUCTION:
PROJECT
NAME:
ADDRESS:
ARCHITECTURAL FIRM
NAME:
ADDRESS:
PHONE:
APPROXIMATE START OF CONSTRUCTION :
GENERAL CONTRACTOR TO PROVIDE A SMOOTH COVE SURFACE AT THE BASE OF
ALL WALLS IN THE FOOD SERVICE AREA. GROUT SHALL BE SMOOTH AND FINISHED
FLUSH WITH THE SURFACE OF THE TILE. REVIEW DETAILS BELOW:
ALL FOOD SERVICE EQUIPMENT IN THESE PLANS WILL BE
MOUNTED ON ONE OF THE FOLLOWING:
SEE FOOD SERVICE SPECIFICATION MANUAL FOR DETAILS ON EACH PIECE OF EQUIPMENT
HAND SINKS KITCHEN EQUIPMENT CONTRACTOR (K.E.C.) TO PROVIDE
A CODE HAND SINK WITH HOT AND COLD WATER UNDER PRESSURE.
SOAP FROM A PERMANENTLY MOUNTED DISPENSER WITH SINGLE USE
TOWELS
ITEM #
CERAMIC TILE
3/8" MIN. RAD.
SLAB
FEATHERED
FEATHERED
COVE BASE
WALL
QUARRY OR
CERAMIC TILE
COVE BASE & FLOOR
3/8" MIN. RAD.
FEATHERED
SLAB
QUARRY OR
WALL
THE FOLLOWING NOTES ARE TO AID IN PROVIDING A SANITARY ENVIRONMENT THAT
WILL MEET LOCAL HEALTH & SANITARIAN CODES.
GENERAL CONTRACTOR (G.C.) TO PROVIDE A SMOOTH, NONABSORBENT, EASY TO
CLEAN SURFACE THAT IS LIGHT IN COLOR FOR ALL WALLS AND CEILINGS IN THE
FOOD SERVICE AREA. SEE FINISH SCHEDULE THIS SHEET.
SECTION 2: PLAN REVIEW
SECTION 5: DESCRIPTION OF FACILITY SECTION 8: PLAN INDEX
NOTE: THIS FINISH SCHEDULE IS
PROVIDED AS A CONVENIENCE
FOR PLAN REVIEW & IS NOT A
PART OF THE BID DOCUMENTS.
REFER TO ARCHITECTURAL
SHEETS FOR FINISHES.
D.
E.
F.
G.
H.
C.
B.
A.
A.
CONCRETE FLOOR TILE FLOOR
STANDARD
EQUIPMENT
6" LEGS 6" CASTERS CURB
SECTION 7: FINISH SCHEDULE
G.C. TO PROVIDE ADEQUATE HEATING & VENTILATION THROUGHOUT THE
ESTABLISHMENT. TO WORK IN CONJUNCTION WITH HOOD SYSTEMS (M) TO KEEP ALL
AREAS REASONABLY FREE FROM EXCESSIVE HEAT, STEAM, SMOKE, CONDENSATION,
ETC. ALSO TO PROVIDE A REASONABLE COMFORT FOR ALL OCCUPANTS OF THE
FACILITY
STANDARD
EQUIPMENT
STANDARD
EQUIPMENT
D.
E.
F.
G.
H.
C.
B.
I.
J.
K.
L.
O.
M.
P.
Q.
R.
S.
T.
N.
SECTION 2: PLAN REVIEW-CONT
ALL EQUIPMENT NOT SEALED TO WALL IS TO HAVE 5"- 6" CASTERS AND EASILY PULLED
OUT FOR CLEANING, UNLESS NOTED OTHERWISE
A MINIMUM OF 36" TO BE MAINTAINED IN ALL AISLES
ALL SHELVES ARE TO BE MADE OF A SMOOTH CLEANABLE SURFACE AND N.S.F.
APPROVED. NO SHELVING TO BE LOWER THAT 8" ABOVE THE FINISHED FLOOR
SECTION 3: EQUIPMENT INSTALL
ALL COUNTER TOP EQUIPMENT THAT IS NOT EASILY REMOVED ARE TO BE INSTALLED ON
4" LEGS TO ALLOW CLEANING, OR SEALED TO THE TABLE WITH AN N.S.F. APPROVED
SILICONE
KITCHEN EQUIPMENT CONTRACTOR TO USE ONLY N.S.F. APPROVED SILICONE WHEN
SEALING APPROPRIATE EQUIPMENT TO WALLS AND WHERE ABUTTED TO OTHER
EQUIPMENT
INSTALL FOODSERVICE EQUIPMENT LEVEL AND PLUMB, ACCORDING TO
MANUFACTURER'S WRITTEN INSTRUCTIONS
PROVIDE CUTOUTS IN EQUIPMENT, NEATLY FORMED, WHERE REQUIRED TO RUN
SERVICE LINES THROUGH EQUIPMENT TO MAKE FINAL CONNECTIONS
COMPLETE EQUIPMENT ASSEMBLY WHERE FIELD ASSEMBLY IS REQUIRED PROVIDE
CLOSED BUTT AND CONTACT JOINTS THAT DO NOT REQUIRE A FILLER. GRIND FIELD
WELDS ON STAINLESS-STEEL EQUIPMENT SMOOTH, AND POLISH TO MATCH
ADJACENT FINISH
RECEIVE ALL EQUIPMENT AND WAREHOUSE UNTIL SCHEDULED INSTALLATION.
EQUIPMENT TO BE LEFT READY FOR FINAL ELECTRICAL AND PLUMBING CONNECTION
BY OTHERS
REMOVE ALL PACKAGING, PALLETS, CARDBOARD AND TRASH RELATED TO THE
FOODSERVICE EQUIPMENT AND PROPERLY DISPOSE. ALL WORK TO BE DONE IN A NEAT
WORKMAN LIKE MANNER. PROVIDE A BINDER WITH ALL EQUIPMENT MANUFACTURERS'
OPERATION MANUALS & WARRANTY
PROVIDE SIX (6) EQUIPMENT SPECIFICATION MANUALS (CUT SHEETS) FOR ALL
EQUIPMENT PROVIDED BY KITCHEN EQUIPMENT CONTRACTOR. ALL TO INCLUDE
COVER SHEETS AND LABELED WITH THE CORRESPONDING EQUIPMENT ITEM
NUMBER WITH SPECIFIED OPTIONS NOTED/MARKED
AFTER COMPLETING INSTALLATION OF EQUIPMENT, REPAIR DAMAGED FINISHES. CLEAN
AND ADJUST EQUIPMENT AS REQUIRED TO PRODUCE READY-FOR-USE CONDITION.
PROTECT EQUIPMENT FROM DAMAGE DURING REMAINDER OF THE CONSTRUCTION
PERIOD
A.
B.
C.
D.
E.
F.
G.
H.
J.
K.
L.
M.
REGIONAL HEALTH DEPARTMENT
OWNERS
NAME:
ADDRESS:
PHONE:
NAME:
ADDRESS:
PHONE:
SECTION 3: EQUIPMENT INSTALL CONT
INSTALL EQUIPMENT WITH ACCESS AND MAINTENANCE CLEARANCES THAT
COMPLY WITH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS AND
REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. INSTALL CLOSURE-TRIM
STRIPS AND SIMILAR ITEMS REQUIRING FASTENERS IN A BED OF SEALANT. INSTALL
JOINT SEALANT IN JOINTS BETWEEN EQUIPMENT AND ABUTTING SURFACES WITH
CONTINUOUS JOINT BACKING, UNLESS OTHERWISE INDICATED. PRODUCE
AIRTIGHT, WATERTIGHT, VERMIN-PROOF, SANITARY JOINTS
I.
YELLOWSTONE NATIONAL PARK, WYOMING
6312 FIDDLERS GREEN CIRCLE, SUITE 600N
GREENWOOD VILLAGE, COLORADO 80111
303-600-3400
A&E ARCHITECTS
222 NORTH HIGGINS
MISSOULA, MT 59802
406.721.5643
MAMMOTH HOTEL
YELLOWSTONE NATIONAL PARK, WY 82190
NATIONAL PARKS SERVICE PUBLIC HEALTH
P.O. BOX 168
YELLOWSTONE NATIONAL PARK, WY 82190
307-344-2273
NEW HOTEL LOBBY BAR WITH BREAKFAST COFFEE COMPONENT. STORAGE IN ADJACENT AREA FOR
BACKSTOCK AND KEGS. SECOND LEVEL PANTRY FOR ON SITE FUNCTION STAGING.
15, 208
N/A
N/A
N/A
N/A
N/A
AUGUST 2016
JUNE 2017
SECTION 1: GENERAL CONTRACTOR SECTION 2: PLUMBING CONTRACTOR
WHERE NOISE OR VIBRATION PRODUCING EQUIPMENT (DISH MACHINE,
DISPOSER, ETC. IS LOCATED ADJACENT TO DINING AREAS AND/OR ANY
PUBLIC AREAS, PROVISIONS SHOULD BE MADE BY THE GENERAL
CONTRACTOR TO "DOUBLE STUD" AND SOUND PROOF COMMON WALLS
IF CANTILEVER BRACKETS FOR TABLE AND STOOLS SEATS OR OTHER
EQUIPMENT ARE SPECIFIED, THE BRACKETS SHALL BE PROVIDED BY K.E.C.
BUT INSTALLED BY GENERAL CONTRACTOR IN ACCORDANCE WITH
SPECIFICATION AND DIMENSIONS PROVIDED BY H-C DESIGN &
CONSULTING
H-C DESIGN & CONSULTING PLANS ARE PROVIDED FOR THE SOLE
PURPOSE OF INDICATING OUTLET LOCATIONS AND EQUIPMENT
REQUIREMENTS ONLY AND DO NOT RELIEVE THE GENERAL CONTRACTOR
OR SUBCONTRACTOR OF THE RESPONSIBILITY OF COMPLYING WITH ALL
APPLICABLE CODES. PLEASE SEE ARCHITECT'S DRAWINGS FOR ALL
OTHER REQUIREMENTS AND CODES
IT IS THE RESPONSIBILITY OF THE OWNER, ARCHITECT AND/OR GENERAL
CONTRACTOR TO INFORM H-C DESIGN & CONSULTING IN WRITING OF ANY
AND ALL CHANGES AND ALL ADDENDUM'S TO PLANS WHICH ARE MADE
PRIOR TO AND DURING CONSTRUCTION. H-C DESIGN & CONSULTING
ASSUMES NO RESPONSIBILITY FOR EQUIPMENT DEVIATIONS OF SIZE
AND/OR UTILITIES FROM LACK OF THIS INFORMATION. THE OWNER WILL
BE RESPONSIBLE FOR ALL COST INCURRED BY FAILURE TO GIVE H-C
DESIGN & CONSULTING NOTICE OF CHANGES
LAST DATED REVISIONS VOID ALL PREVIOUS PLANS
GENERAL CONTRACTOR TO PROVIDE FLOOR RECESSES (FLAT AND LEVEL),
VAPOR BARRIERS AND BUILT IN INSULATED FLOORS (AS SHOWN ON
PLANS) IF REQUIRED
GENERAL CONTRACTOR TO PROVIDE ACCESS TO HOODS AT AREA ABOVE
HOODS FOR MOUNTING OF HOOD SUPPORTS. IF ACCESS IS NOT
PROVIDED, GENERAL CONTRACTOR TO PROVIDE HOOD SUPPORTS
GENERAL CONTRACTOR TO PROVIDE SPRINKLER HEADS IN WALK-IN BOXES
ADEQUATELY PROTECTED AGAINST FREEZING (IF REQUIRED BY LOCAL
CODE)
REMOVAL OF WINDOW GLASS, WINDOW FRAMES, DOORS, DOOR FRAMES
AND CENTER POST FOR ENTRY OF EQUIPMENT SHALL BE THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR AND AT NO EXPENSE TO
K.E.C
GENERAL CONTRACTOR TO PROVIDE ALL WALL BACKING PER LOCATION
AND SPECIFICATION BY H-C DESIGN & CONSULTING
ALL DIMENSIONS SHOWN ARE MEASURED FROM FINISHED WALLS,
FLOORS, CEILINGS AND/OR COLUMN TO CENTER LINES OF STUBS OR
OUTLETS. ALLOWANCES SHALL BE MADE FOR MISCELLANEOUS
OBSTRUCTIONS, STRUCTURES, VENTING, ELECTRICAL, PLUMBING AND
THICKNESS OF FINISHES WHEN FRAMING AND/OR ROUGHING-IN AS
REQUIRED
WEARING FLOOR FINISH AND COVE BASE IN WALK-IN BOXES TO BE
PROVIDED BY GENERAL CONTRACTOR UNLESS OTHERWISE SPECIFIED BY
K.E.C
SLEEVES TO BE PROVIDED BY GENERAL CONTRACTOR IN WALLS, FLOORS
AND CEILING FOR LINES (DRAINS, REFRIGERATION, ETC.) TO PASS
THROUGH AND RESEAL AFTER LINES ARE RUN
WHEN EQUIPMENT IS NOTED AS EXISTING OR BY VENDOR, UTILITY
REQUIREMENTS SHOULD MATCH AS INDICATED ON THE MANUFACTURE'S
DATA PLATE. IF EXISTING EQUIPMENT IS NOT RELOCATED, RECONNECT AS
REQUIRED IN ACCORDANCE WITH APPLICABLE CODES
WHERE INDICATED TO CONNECT IN OR THROUGH VALVE COMPARTMENT,
CONTRACTOR SHALL STUB-UP INTO VALVE COMPARTMENT AT HEIGHT
INDICATED ON ROUGH-IN PLAN, CAP THEIR WORK AND MAKE FINAL
CONNECTIONS AFTER EQUIPMENT IS IN PLACE
PLUMBING CONTRACTOR TO PROVIDE GAS SHUTOFF SOLENOID VALVE FOR
EXHAUST HOOD(S) FIRE SUPPRESSION SYSTEM. PLUMBING CONTRACTOR
TO INSTALL. ELECTRICAL CONTRACTOR TO INTER-WIRE WITH EXHAUST
FAN(S) PER CODE
GENERAL CONTRACTOR TO PROVIDE WASTE CONTAINER AT JOB SITE FOR
K.E.C. UNLESS OTHERWISE NOTED BY H-C DESIGN & CONSULTING
K.E.C. TO PROVIDE STAINLESS STEEL (304 16 GA.) CORNER GUARDS ON ALL
CORNERS AND ENDS OF WALLS AS NOTED BY H-C DESIGN & CONSULTING
K.E.C. TO PROVIDE STAINLESS STEEL (AT LEAST 304 22 GA.) WALL
FLASHING (WITH PATTERN AS NOTED) IN ALL AREAS NOTED BY H-C DESIGN
& CONSULTING. HCDC RECOMMENDS AN OVERHANG OF EIGHTEEN INCHES
ON ALL AREAS IN CONTACT WITH HOOD. VERIFY WITH ALL APPLICABLE
CODES AND ORDINANCES
THE PLUMBING ROUGH-INS AND CONNECTIONS SHOWN ON THESE PLANS
ARE FOR FOOD SERVICE EQUIPMENT REQUIREMENTS ONLY. IT IS THE
RESPONSIBILITY OF THE PLUMBING CONTRACTOR (P.C.) TO CONSULT THE
ARCHITECT'S, ENGINEERS AND/OR OTHER CONSULTANT'S PLANS AND THE
OWNER FOR FURTHER BUILDING PLUMBING REQUIREMENTS
PLUMBING CONTRACTOR TO PROVIDE AND INSTALL ALL REQUIRED MATERIALS TO
COMPLETE CONNECTIONS , SUCH AS STOPS, VALVES, FILTERS, CHECK VALVES,
PRESSURE REDUCING VALVES, GATE VALVES, SOLENOID VALVES, SIPHON
BREAKERS, PIPING, TUBING, MISC. FITTINGS, TRAPS, ETC. UNLESS OTHERWISE
SPECIFIED BY H-C DESIGN & CONSULTING
VERIFY ALL PLUMBING ROUGH-INS AND LOCATION WITH OWNER, VENDOR OR G.C.
ON EXISTING EQUIPMENT OR OTHER EQUIPMENT NOT PROVIDED BY K.E.C
PLUMBING CONTRACTOR TO FURNISH AND INSTALL THE FOLLOWING IN
ACCORDANCE WITH APPLICABLE CODES
ALL WATER, WASTE, GAS, AND STEAM SERVICE TO POINT OF ROUGH-IN AS
SHOWN ON PLAN. ROUGH-IN OUTLETS TO STUB 4" OUT OF WALLS AT
HEIGHT INDICATED FROM FINISHED FLOOR TO CENTER LINE OF OUTLET
PRESSURE REDUCING AND/OR REGULATING VALVES FOR DISHWASHERS,
AND OTHERS AS OTHERWISE NOTED, IN KITCHEN AREAS
ALL FLOOR SINKS, COMPLETE WITH TOP GRATES INDICATED, AND
REMOVABLE SEDIMENT BUCKETS SET FLUSH WITH FINISHED FLOOR,
UNLESS NOTED OR AS PER LOCAL CODE
ALL WASTE LINES, DIRECT OR INDIRECT, EXCEPT AS NOTED, SHALL BE
PITCHED DOWNWARD. ALL WASTE LINES SHALL HAVE ADEQUATE
CLEAN-OUT PROVISIONS
PLUMBING CONTRACTOR TO PROVIDE AND INSTALL ALL INDIRECT WASTE
LINES FOR WALK-IN COOLER/FREEZER EVAPORATOR COILS
INSTALL IN AN ACCESSIBLE LOCATION THE FIRE CONTROL GAS SHUTOFF
VALVE AS SUPPLIED BY PLUMBING CONTRACTOR. (IF GAS COOKING
EQUIPMENT IS USED)
VACUUM BREAKERS AS REQUIRED
INSULATION OF ALL STEAM, HOT WATER AND CONDENSATE RETURN LINES
IN KITCHEN
CLEAN-OUT VALVES FOR STEAM CONDENSATE, AND AIR LINES
ALL PIPING TO AND FROM EQUIPMENT SHALL BE KEPT AT A MINIMUM
OF (6") ABOVE FINISHED FLOOR TO ALLOW FOR CLEANING. UNI-STRUT
NOT TO BE UTILIZED OR FASTENED TO FLOORING SURFACE IN ANY
INSTANCE. STAINLESS STEEL UNI-STRUT TO BE USED AND SECURED
TO UNDERSIDE OF FIXED EQUIPMENT OR WALLS TO HELP IN ROUTING
OF WATER CONNECTIONS OR DRAINS. ROUTING TO NOT IMPEDE THE
ACCESS, FUNCTIONALITY OR MAINTENANCE OF EQUIPMENT.
IN LINE WATER FILTERS ARE RECOMMENDED FOR THE FOLLOWING
EQUIPMENT: (WATER FILTER BY K.E.C. ONLY WHEN NOTED)
GLASS WASHERS, SODA SYSTEMS, ICE MACHINES, STEAM
EQUIPMENT, WATER HEATERS, BOOSTER HEATERS, SINK
HEATERS, DISH MACHINES
PLUMBING CONTRACTOR TO INTERCONNECT DISH MACHINE WITH BOOSTER
HEATER AND WATER-TYPE VENTILATORS WITH CONTROL PANELS AS PER
MANUFACTURER'S INSTRUCTION, WHEN APPLICABLE AND NOTED
ALL LINES ROUTED THROUGH EQUIPMENT SHALL NOT INTERFERE WITH INTENDED
USE OF, OR SERVICING OF EQUIPMENT
ALL VENT PIPES ARE TO BE CONCEALED IN WALLS OR COLUMN CHASES
INTERCONNECTION BETWEEN STEAM EQUIPMENT AND STEAM GENERATOR WHEN
STEAM IS USED
GREASE INTERCEPTOR TO BE SPECIFIED AND LOCATED BY MECHANICAL
ENGINEER. PROVIDED AND INSTALLED BY MECHANICAL OR PLUMBING
CONTRACTOR PER LOCAL CODE
WHERE EQUIPMENT IS NOTED AS EXISTING, UTILITY REQUIREMENTS SHOULD BE
VERIFIED AND MATCH AS INDICATED ON MANUFACTURER'S DATA PLATE. IF
EQUIPMENT IS NOT RELOCATED, RECONNECT AS REQUIRED BY CODE. PLUMBING
CONTRACTOR TO VERIFY EXISTING UTILITIES AND EQUIPMENT REQUIREMENTS
AND REUSE IF POSSIBLE
ALL PLUMBING LOCATIONS ARE SHOWN AT OPTIMUM SPOTS. UTILIZE ALL EXISTING
SERVICES WHERE APPLICABLE
ALL PLUMBING TO BE CONCEALED WITHIN WALLS WHERE POSSIBLE
ALL PLUMBING LINES WITHIN FIXTURES, ARE TO BE RUN THROUGH BULKHEADS,
RACEWAYS, AND BEHIND SHELVES WHEREVER POSSIBLE
HOT WATER HEATER TO PROVIDE A MINIMUM OF 140 DEGREE TO DISHWASHER ONLY
ALL DIMENSIONS SHOWN ARE MEASURED FROM FINISHED WALLS, FLOORS,
CEILINGS AND/OR COLUMN TO CENTER LINES OF STUBS OR OUTLETS. THE
PLUMBING CONTRACTOR SHALL MAKE ALLOWANCES FOR MISCELLANEOUS
OBSTRUCTIONS SUCH AS PIPING MAINS, ELECTRICAL COMPONENTS, STRUCTURES,
VENTING AND THICKNESS OF FINISHES WHEN ROUGHING IN
ALL FAUCETS AND/OR DISPOSERS LOCATED ON FOODSERVICE PLAN SHALL BE
PROVIDED BY K.E.C. AND INSTALLED BY PLUMBING CONTRACTOR, UNLESS
OTHERWISE NOTED
HAND SINKS ARE TO BE MOUNTED AND INSTALLED BY PLUMBING CONTRACTOR
PLUMBING CONTRACTOR TO PROVIDE AND INSTALL ALL BACK FLOW PREVENTION
DEVICES REQUIRED ON EQUIPMENT, IN ACCORDANCE WITH APPLICABLE CODES
THE ELECTRICAL ROUGH-INS AND CONNECTIONS SHOWN ON THESE PLANS ARE FOR
FOOD SERVICE EQUIPMENT REQUIREMENTS ONLY. IT IS THE RESPONSIBILITY OF THE
ELECTRICAL CONTRACTOR (E.C.) TO CONSULT THE ARCHITECT'S, ELECTRICAL
ENGINEERS AND/OR OTHER CONSULTANT'S PLANS AND THE OWNER FOR FURTHER
BUILDING ELECTRICAL REQUIREMENTS
THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL COMPRESSORS AND PROVIDE
FUSED DISCONNECTS, MAGNETIC STARTERS AND THERMAL OVERLOAD
PROTECTION AS REQUIRED
VAPOR PROOF LIGHT FIXTURES AND SWITCH BOXES FOR EXHAUST HOODS SHALL
BE FURNISHED BY THE MECHANICAL CONTRACTOR AND INSTALLED BY E.C. THE
ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL, CONDUIT, WIRE, BULBS,
ETC. PROVIDE AND CONNECT TO A WALL MOUNTED SWITCH (WITH PILOT LIGHT),
UNLESS OTHERWISE NOTED
VAPOR PROOF LIGHT FIXTURES FOR WALK-IN COOLERS AND FREEZERS SHALL BE
FURNISHED WITH AN EXTERIOR PILOT LIGHT SWITCH BY THE KITCHEN EQUIPMENT
CONTRACTOR, IF APPLICABLE. IT SHALL BE THE RESPONSIBILITY OF THE
ELECTRICAL CONTRACTOR TO INTERCONNECT AND INSTALL THESE ITEMS AS
REQUIRED. ELECTRICAL CONTRACTOR SHALL INTERCONNECT LIGHTING, DOOR
HEATERS, DRAIN HEAT TAPE OR RELIEF PORTS WITH EVAPORATOR
ELECTRICAL CONTRACTOR TO INTERCONNECT THE REMOTE REFRIGERATIONS'
COMPRESSOR, EVAPORATOR, THERMOSTAT, SOLENOID AND DEFROST TIMER (ALL
CONTROLS) WHERE REQUIRED
ALL ELECTRICAL MATERIALS INCLUDING WIRING, FLEX, CONDUIT, SWITCHES,
DISCONNECTS, MAGNETIC STARTERS, THERMO-OVERLOAD PROTECTORS,
TRANSFORMERS, ELECTRICAL PANELS, CORDS, PLUGS, RECEPTACLES, BULBS,
ETC. SHALL BE SUPPLIED BY THE ELECTRICAL CONTRACTOR UNLESS SPECIFIED IN
THESE PLANS OR IN WRITING
IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE
WATER PROOF POWER OUTLET(S) ON THE ROOF FOR EXHAUST SYSTEM FAN(S)
MAKE-UP AIR FAN(S) AND REFRIGERATION SYSTEM(S) AS REQUIRED. LOW VOLTAGE
(OR COMMON VOLTAGE) WIRING SHALL ALSO BE SUPPLIED AND INSTALLED BY THE
ELECTRICAL CONTRACTOR WHEN NECESSARY TO CONTROL AND INTERCONNECT
THE ABOVE SYSTEMS
THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ANY AND ALL
ELECTRICAL EQUIPMENT AS REQUIRED BY APPLICABLE CODES AND ORDINANCES.
ELECTRICAL CONTRACTOR TO VERIFY NECESSARY REQUIREMENTS
ALL DIMENSIONS SHOWN ON THESE PLANS ARE MEASURED FROM FINISHED WALLS,
FLOORS, CEILINGS AND/OR COLUMN CENTER LINES OR GRID LINES TO CENTER
LINES OF OUTLETS AND PULL BOXES. THE ELECTRICAL CONTRACTOR SHALL MAKE
ALLOWANCES FOR FINISHES WHEN ROUGHING-IN
THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ELEMENT CONTACT
(RELAY) SHUTOFFS (SHUNT TRIP) AND/OR SOLENOID SHUTOFF VALVE AND
INTERCONNECT WITH THE FIRE SUPPRESSION SYSTEM FOR THE COOKING
EQUIPMENT, TO SHUT OFF ALL EQUIPMENT AUTOMATICALLY IN CASE OF FIRE.
VERIFY WITH LOCAL CODES FOR SHUTDOWN OF EXHAUST FAN(S) AND OR MAKE-
UP AIR FAN(S) REQUIREMENTS. ONLY APPLICABLE FOR CLASS I HOOD SYSTEM
THE KITCHEN EQUIPMENT CONTRACTOR WILL UNCRATE AND INSTALL ALL
EQUIPMENT THAT THE KITCHEN EQUIPMENT CONTRACTOR PROVIDES AS WELL AS
ANY EQUIPMENT NOTED TO BE RELOCATED AND INSTALLED BY THE KITCHEN
EQUIPMENT CONTRACTOR (K.E.C.). SEE INSTALLATION NOTES ON THE FS0.0 SHEET
THE KITCHEN EQUIPMENT CONTRACTOR WILL NOT BE RESPONSIBLE FOR THE
FOODSERVICE VENTILATION HOODS. SEE DIV. 23
THE KITCHEN EQUIPMENT CONTRACTOR WILL REVIEW ALL MANUFACTURERS SHOP
DRAWINGS, VERIFY AS BUILTS AT SITE FOR EQUIPMENT, MAKE CHANGES IF NEEDED
AND SIGN OFF ON SHOP DRAWINGS AND SEND A COPY TO H-C DESIGN &
CONSULTING
KITCHEN EQUIPMENT CONTRACTOR WILL VISIT THE SITE BEFORE INSTALL TO
VERIFY ALL AS BUILT DIMENSIONS TO INSURE PROPER INSTALLATION OF
FOODSERVICE EQUIPMENT
ANY SUBSTITUTIONS MUST BE APPROVED BY H-C DESIGN & CONSULTING AND MEET
THE REQUIREMENTS BELOW:
THE PROPOSED SUBSTITUTION DOES NOT AFFECT DIMENSIONS SHOWN ON
DRAWINGS
THE KITCHEN EQUIPMENT CONTRACTOR WILL PAY FOR CHANGES TO THE
BUILDING DESIGN, INCLUDING ENGINEERING DESIGN, DETAILING AND
CONSTRUCTION COSTS CAUSED BY THE SUBSTITUTION REQUEST
THE PROPOSED SUBSTITUTION WILL HAVE NO ADVERSE AFFECT ON OTHER
TRADES, THE CONSTRUCTION SCHEDULE OR SPECIFIED WARRANTY
REQUIREMENTS
MAINTENANCE AND SERVICE PARTS WILL BE LOCALLY AVAILABLE FOR THE
PROPOSED SUBSTITUTION
SECTION 3: ELECTRICAL CONTRACTOR
A LIQUID CHEMICAL SYSTEM SHALL BE PROVIDED TO PROTECT ALL COOKING
EXHAUST HOODS, DUCTS, AND COOKING APPLIANCES AGAINST FIRE AND
RE-FLASH. THE SIZE AND NUMBER OF SYSTEMS SHALL BE IN CONFORMANCE WITH
LOCAL AND STATE CODES. THE SYSTEM SHALL BE INSTALLED BY AUTHORIZED
INSTALLERS, IN ACCORDANCE WITH U.L. LISTING
THE SYSTEM SHALL BE AUTOMATICALLY ACTUATED OR MANUALLY OPERABLE AT
THE NOZZLE RELEASE AND A REMOTE MANUAL PULL STATION. ACTUATION OF THE
SYSTEM SHALL PROVIDE AUTOMATIC GAS AND\OR ELECTRIC FUEL LINE CUT-OFF
FIRE SUPPRESSION CONTRACTOR TO PROVIDE GAS SHUTOFF SOLENOID VALVE
WITH FIRE SUPPRESSION SYSTEM
ELECTRICAL COOKING EQUIPMENT SHALL BE SHUTOFF AT THE ELECTRICAL PANEL
BY MEANS OF SHUNT TRIPS. ELECTRICAL CONTRACTOR SHALL FURNISH AND
INSTALL SHUNT TRIPS, LINE VOLTAGE WIRING AND CONDUIT FROM FIRE
PROTECTION MICRO-SWITCH TO PANELS, TO MEET ALL APPLICABLE CODES
PROVIDE WALK-IN REFRIGERATOR/FREEZER DEPRESSIONS. TROWEL SMOOTH AND
LEVEL. DEPTH AS NOTED BY H-C DESIGN & CONSULTING
FILL EXCESS DEPRESSION AROUND WALK-IN REFRIGERATOR/FREEZER WITH GROUT,
FINISH FLOOR MATERIAL, AND COVERED AFTER REFRIGERATOR/FREEZER INSTALLED
BY K.E.C
PROVIDE MASONRY PADS WITH TROWELLED SMOOTH AND LEVEL TOP AS REQUIRED
PROVIDE COVED BASE-MOLDING OR COVED INTEGRAL FLOOR MATERIALS AS
REQUIRED AT ALL VERTICAL SURFACES FOR KITCHEN FLOOR
ALL CURBS OR RECESSED MAT AREA DIMENSIONS ARE FINISHED DIMENSIONS.
VERIFY FACE AND TOP FINISHES (WHERE CURB IS EXPOSED ) WITH ARCHITECT,
GENERAL CONTRACTOR OR OWNER
ALL CURBS HEIGHTS TO BE TAKEN FROM FINISHED FLOOR TO TOP OF FINISHED
CURB
ALL CURB DIMENSIONS ARE TAKEN FROM FINISHED WALL TO FACE OF FINISHED
CURB, OR FROM FINISHED FACE OF CURB TO FINISHED FACE OF CURB
SEE PLUMBING PLAN(S) FOR EXACT LOCATION OF FLOOR SINKS AND FLOOR
DRAINS. VERIFY WITH PLUMBING CONTRACTOR
GENERAL CONTRACTOR (G.C.) TO CUT AND PROVIDE HOLES THROUGH
CEILING, ROOFS, WALLS AND FLOORS FOR DUCTS, ETC. IN ACCORDANCE
WITH LOCAL FIRE AND BUILDING CODES AND IN ACCORDANCE WITH DUCT
SIZES SPECIFIED. GENERAL CONTRACTOR TO PROVIDE THE RESEALING
OF ALL HOLES( INCLUDING THE "MOPPING-IN" OF FAN CURBS AND ROOF
JACKS). GENERAL CONTRACTOR TO PROVIDE ALL DUCT FIRE SEPARATION
ENCLOSURES, WRAPPINGS, ETC. AS MAY BE REQUIRED BY LOCAL
BUILDING AND FIRE CODES
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
1.
2.
3.
4.
A.
B.
C.
D.
E.
F.
G.
H.
SECTION 6: KITCHEN EQUIPMENT CONTRACTOR
SECTION 4: CONCRETE CONTRACTOR
SECTION 5: FIRE SUPPRESSION CONTRACTOR
AT THE COMPLETION OF PROJECT, THE KITCHEN EQUIPMENT CONTRACTOR IS TO
PROVIDE (2) OPERATION AND MAINTENANCE MANUALS IN DIVIDED SECTION
BINDERS ITEMIZED BY MANUFACTURER. LOCAL SERVICE AGENTS ARE TO BE
LISTED BY MANUFACTURER ON A SEPARATE SHEET AT FRONT OF BINDER
KITCHEN EQUIPMENT CONTRACTOR TO PERFORM INITIAL STARTUP OF EQUIPMENT
AND COORDINATE TRAINING BY K.E.C. AND/OR MANUFACTURER REPRESENTATIVES
H-C DESIGN & CONSULTING RECOMMENDS THE USE OF STEEL STUD
FRAMING OF ALL WALLS THAT ARE IN CONTACT WITH CLASS 1 HOOD
SYSTEMS. VERIFY WITH LOCAL CODES
U.
K.E.C. TO PROVIDE STAINLESS STEEL (304 16 GA.) CORNER GUARDS ON ALL
CORNERS AND ENDS OF WALLS AS NOTED BY H-C DESIGN & CONSULTING
K.E.C. TO PROVIDE STAINLESS STEEL (AT LEAST 304 20 GA.) WALL FLASHING (WITH
PATTERN AS NOTED) IN ALL AREAS NOTED BY H-C DESIGN & CONSULTING. HCDC
RECOMMENDS AN OVERHANG OF EIGHTEEN INCHES ON ALL AREAS IN CONTACT
WITH HOOD. VERIFY WITH ALL APPLICABLE CODES AND ORDINANCESALL PROPOSED FOODSERVICE SPECIFIED OUTLETS TO BE DESIGNED TO HAVE
DEDICATED BREAKERS WITHOUT PARALLEL OR SERIES CIRCUITS
EXISTING EQUIPMENT COORDINATION: IT IS THE SOLE RESPONSIBILITY OF THE KEC
TO LOCATE AND VERIFY EXISTING EQUIPMENT SIZES, DIMENSIONS AND LOADS
PRIOR TO ORDERING ANY AND/OR ALL COMPONENTS INTENDED FOR USE WITH
EXISTING ITEMS
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
A.
B.
C.
D.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
A.
SECTION 7: VENTILATION CONTRACTOR
MECHANICAL CONTRACTOR TO PROVIDE DUCT WORK, (ALL WELDING OF HOOD AND
DUCT REQUIRED) CONTROLS, DUCT COLLAR, TRANSITIONS, FIRE WRAP, FINAL
CONNECTIONS, PERMITS, AND ALL OTHER FASTNERS/HARDWARE TO INSURE
PROPER INSTALLATION, UNLESS OTHERWISE SPECIFIED. SPECIFICATION OF ABOVE
BY MECHANICAL ENGINEER. MECHANICAL CONTRACTOR TO INSTALL HOODS PER
LOCAL CODE
MECHANICAL CONTRACTOR (H.V.A.C.) TO BALANCE EXHAUST SYSTEM.
ALL ROOF CURB TO BE PROVIDED BY M.C. INSTALLED BY M.C. INCLUDING
RESEALING OF ROOF AND ROOF PENETRATIONS, UNLESS OTHERWISE NOTED
ALL C.F.M. REQUIREMENTS SHOWN ON DRAWING TO BE VERIFIED BY MECHANICAL
ENGINEER. ALL C.F.M. SPECIFIED BY H-C DESIGN & CONSULTING ARE RATED AT
DUCT COLLAR ONLY AND DO NOT INCLUDE ANY STATIC PRESSURE OF DUCT
REQUIRED (UNLESS NOTED)
ALL DUCT COLLARS, CUTOUTS AND PENETRATIONS IN HOODS TO BE LOCATED AND
PROVIDED BY MECHANICAL CONTRACTOR IN FIELD
GENERAL CONTRACTOR TO PROVIDE ALL DUCT CHASES FROM HOOD THROUGH ROOF
IN ACCORDANCE WITH APPLICABLE CODES
MECHANICAL CONTRACTOR TO PROVIDE KITCHEN EXHAUST HOODS, FANS
(EXHAUST & MAKE UP AIR UNITS). FIRE SUPPRESSION BY M.C. OR LOCAL FIRE
SUPPRESSION CONTRACTOR (AS NOTED)
THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ANY AND ALL
MECHANICAL EQUIPMENT AS REQUIRED BY APPLICABLE CODES AND ORDINANCES.
MECHANICAL CONTRACTOR TO VERIFY NECESSARY REQUIREMENTS
A.
B.
C.
D.
E.
F.
G.
H.
PLUMBING CONTRACTOR TO PROVIDE AND INSTALL INSULATED DRAIN LINES FROM
ALL ICE STORAGE PANS TO PREVENT DRAIN FROM SWEATING WITHIN FIXTURES.
WHERE EXPOSED OR SEMI-EXPOSED, PROVIDE BRIGHT CHROME PLATED BRASS
OR POLISHED STAINLESS STEEL UNITS. PROVIDE COPPER OR BRASS WHERE NOT
EXPOSED.
T.
ALL COUNTERTOP UNITS REQUIRING A WATER CONNECTION TO HAVE FLEXIBLE
BRAIDED STAINLESS STEEL SUPPLY HOSE.U.
SECTION 2: PLUMBING CONTRACTOR CONT.
YTEICOSSTNAT
LU
SN
OC
L A
N
OI
T A
N R E T
NI
E
CI
V R
E S
D O
O F
RE
BM
EMLANOISSEFORP
707871
MICHAEL MILES
MEASUREMENTS ON THIS PLAN HAVE BEEN ASSEMBLED BY H-C DESIGN & CONSULTING. HOWEVER NO RESPONSIBILITY FOR THE ACCURACY OF SUCH MEASUREMENTS WILL BE TAKEN BY H-C D&C. ALL UTILIZING THESE PLANS ARE RESPONSIBLE FOR VERIFYING ANY MEASUREMENTS OF THEIR CONCERN. ALL MECHANICAL INFORMATION IS FOR THE SOLE PURPOSE OF IDENTIFYING THE REQUIREMENTS OF THE FOODSERVICE EQUIPMENT AND IS IN NO WAY ENGINEERED BY H-C D&C. H-C DESIGN & CONSULTING ASSUMES NO RESPONSIBILITY FOR CHANGES DICTATED BY AS-BUILT CONDITIONS, EXISTING/ OWNER PROVIDED EQUIPMENT,LOCAL BUILDING CODES, STRUCTURAL CONDITIONS, HEALTH DEPARTMENT, ORDINANCES, AS WELL AS MODIFICATIONS TO THIS PLAN AND WORK PERFORMED BY CONTRACTORS. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING THE GENERAL NOTES AS PART OF THESE PLANS BEFORE WORK IS TO BEGIN. ANY ISSUES, DISCREPANCIES OR INCONSISTENCIES FOUND IN THESE PLANS AND OR WITH LOCAL CODES MUST IMMEDIATELY BE CALLED TO THE ATTENTION OF H-C D&C IN WRITING SO THE APPROPRIATE ACTION CAN BE TAKEN. THESE PLANS AND THEIR CONTENTS ARE THE PROPERTY OF H-C D&C AND MAY ONLY BE REPRODUCED WITH PERMISSION BY H-C DESIGN & CONSULTING.
A R C H I T E C T U R E I N T E R I O R S H I S T O R I C www.aearchitects.com
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 5 9 8 0 2 P H. 4 0 6 . 7 2 1 . 5 6 4 3 F A X. 4 0 6 . 7 2 1 . 1 8 8 7
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 5 9 1 0 1 P H. 4 0 6 . 2 4 8 . 2 6 3 3 F A X. 4 0 6 . 2 4 8 . 2 4 2 7
4 2 8 E A S T M E N D E N H A L L B O Z E M A N, M T 5 9 7 1 5 P H. 4 0 6 . 4 5 3 . 7 3 1 0
PROJECT NO.
NPS PROJ NO.
REVISIONS
DRAWING NO.
PKG
NO.
PKG1
PKG2
PKG3
SHEET
OF
DESIGNED:
CADD:
TECH REVIEW:
DATE
TITLE OF SHEETDRAWING NO.
0 1 2 3 4 5 6 7 8 9 10 inches
189105
/1
/2
:3
:2
P M
15021.00 06.10.2016
FS GENERAL NOTES
MAMMOTH HOTEL SEISMIC
STABILIZATION & REHABILITATION
PHASE I.
YELLOWSTONE NATIONAL PARK, WYOMING
AMT
MM
MM
06.10.2016
FS0.1
CO
N
ST
RU
C T
IO
N D
O
CU
M
EN
T S
18" X 42"
18" X 30"
21" X 42"
*Manitowoc
18" X 42"18" X 42"18" X 42"
KEC
KEC-ALT
OSCI
NIC
FUTURE
DIV 22/23
DIV 26
KITCHEN EQUIPMENT CONTRACTOR
KEC ALTERNATE EQUIPMENT
OWNER SUPPLIED, CONTRACTOR (KEC) INSTALLED
BY OTHERS - NOT IN KEC CONTRACT
FUTURE EQUIPMENT
SEE DIVISION 22/23 - MECHANICAL CONTRACTOR
SEE DIVISION 26 - ELECTRICAL CONTRACTOR
SOURCE LEGEND
LEGEND OF SYMBOLS
ELEVATION MARKER
GENERAL DETAIL MARKER
EQUIPMENT TAG
SHEET
REF. NUMBER
A101
1422 161718
MILLWORK BY OTHERS,
SEE ARCHECT'S SHEETS
MILLWORK BY OTHERS,
SEE ARCHECT'S SHEETS
25 24 23
261 28 27
2934 28
CLOSURE PANELS
WALK
IN TRIM
39 3441
B
A
C
FS1.0
FS1.0
ICE
MACHINE
STORAGE
EC PANELS
SODA STORAGE
1 25 232426
8.1
28 32
FS1.01
FS1.0
DIV
/23
WALK
IN TRIM
WEIGHT:
176 LB
WALK IN COMPRESSOR
SEE MECHANICAL
DRAWINGS
ICE MAKER
COMPRESSOR
WEIGHT:
203 LBS
2'
1/
4"
1' - 11 3/4"
2'
1/
8"
2' - 10"
29.1 38.0
MILLWORK BY OTHERS,
SEE ARCHECT'S SHEETS
MILLWORK BY OTHERS,
SEE ARCHECT'S SHEETS
7 7 4 3 2
DIV
/23
YTEICOSSTNAT
LU
SN
OC
L A
N
OI
T A
N R E T
NI
E
CI
V R
E S
D O
O F
RE
BM
EMLANOISSEFORP
707871
MICHAEL MILES
MEASUREMENTS ON THIS PLAN HAVE BEEN ASSEMBLED BY H-C DESIGN & CONSULTING. HOWEVER NO RESPONSIBILITY FOR THE ACCURACY OF SUCH MEASUREMENTS WILL BE TAKEN BY H-C D&C. ALL UTILIZING THESE PLANS ARE RESPONSIBLE FOR VERIFYING ANY MEASUREMENTS OF THEIR CONCERN. ALL MECHANICAL INFORMATION IS FOR THE SOLE PURPOSE OF IDENTIFYING THE REQUIREMENTS OF THE FOODSERVICE EQUIPMENT AND IS IN NO WAY ENGINEERED BY H-C D&C. H-C DESIGN & CONSULTING ASSUMES NO RESPONSIBILITY FOR CHANGES DICTATED BY AS-BUILT CONDITIONS, EXISTING/ OWNER PROVIDED EQUIPMENT,LOCAL BUILDING CODES, STRUCTURAL CONDITIONS, HEALTH DEPARTMENT, ORDINANCES, AS WELL AS MODIFICATIONS TO THIS PLAN AND WORK PERFORMED BY CONTRACTORS. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING THE GENERAL NOTES AS PART OF THESE PLANS BEFORE WORK IS TO BEGIN. ANY ISSUES, DISCREPANCIES OR INCONSISTENCIES FOUND IN THESE PLANS AND OR WITH LOCAL CODES MUST IMMEDIATELY BE CALLED TO THE ATTENTION OF H-C D&C IN WRITING SO THE APPROPRIATE ACTION CAN BE TAKEN. THESE PLANS AND THEIR CONTENTS ARE THE PROPERTY OF H-C D&C AND MAY ONLY BE REPRODUCED WITH PERMISSION BY H-C DESIGN & CONSULTING.
A R C H I T E C T U R E I N T E R I O R S H I S T O R I C www.aearchitects.com
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 5 9 8 0 2 P H. 4 0 6 . 7 2 1 . 5 6 4 3 F A X. 4 0 6 . 7 2 1 . 1 8 8 7
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 5 9 1 0 1 P H. 4 0 6 . 2 4 8 . 2 6 3 3 F A X. 4 0 6 . 2 4 8 . 2 4 2 7
4 2 8 E A S T M E N D E N H A L L B O Z E M A N, M T 5 9 7 1 5 P H. 4 0 6 . 4 5 3 . 7 3 1 0
PROJECT NO.
NPS PROJ NO.
REVISIONS
DRAWING NO.
PKG
NO.
PKG1
PKG2
PKG3
SHEET
OF
DESIGNED:
CADD:
TECH REVIEW:
DATE
TITLE OF SHEETDRAWING NO.
0 1 2 3 4 5 6 7 8 9 10 inches
189105
/1
/2
:3
:2
P M
15021.00 06.10.2016
FS FLOOR PLAN - BAR
MAMMOTH HOTEL SEISMIC
STABILIZATION & REHABILITATION
PHASE I.
YELLOWSTONE NATIONAL PARK, WYOMING
AMT
AMT
MM
06.10.2016
FS1.0
CO
N
ST
RU
C T
IO
N D
O
CU
M
EN
T S
: 3/8" = 1'-0"FS1.0FS1.0
2 FRONT BAR
: 3/8" = 1'-0"FS1.0FS1.0
4 BEER/WINE TAPS
: 3/8" = 1'-0"FS1.0FS1.0
5 BACK BAR - WEST
: 3/8" = 1'-0"FS1.0FS1.0
3 WALK IN
: 3/8" = 1'-0"FS1.0FS1.0
6 8 BACK BAR - EAST
FOODSERVICE EQUIPMENT SCHEDULE - FIRST FLOOR
ITEM
NO SOURCE QTY UNIT DESCRIPTION MANUFACTURER MODEL
EQUIPMENT
REMARKS
1 KEC 1 EA SELF-CONTAINED BACK BAR 3-DOOR REFRIGERATOR PERLICK BBS84
2 KEC 1 EA DISPENSER, MILK SILVER KING SKMAJ1
3 KEC 1 EA COFFEE MAKER, AIRPOT BUNN-O-MATIC CWTF-APS-0046
4 KEC 1 EA COFFEE GRINDER BUNN-O-MATIC G9-2T-HD-0021
5 1 NOT USED NOT USED NOT USED
6 DIV 22/23 1 LOT COUNTERTOP DROP-IN SINK
7 KEC 2 EA COFFEE GRINDER NUOVA SIMONELLI USA EURKEA MDE
8 KEC 1 EA ESPRESSO MACHINE NUOVA SIMONELLI USA AURELIA 2GR SEM
9 KEC 1 LOT HOT FOOD MERCHANDISERS CAL-MIL 1575-74
10 1 NOT USED NOT USED NOT USED
11 NIC 1 EA POINT OF SALE
12 KEC 1 EA BACK BAR 1-DOOR REFRIGERATOR PERLICK BBS36
13 KEC 1 EA CORNER FILLER SECTION PERLICK CM14715
14 KEC 1 EA SINK PERLICK TS53C
15 KEC 1 EA ONE TANK HAND SINK PERLICK TS12HSN
16 KEC 1 EA SODA GUN FILLER SECTION PERLICK TS4SGA
17 KEC 1 EA COCKTAIL STATION ICE CHEST PERLICK TSC30IC10
18 KEC 1 EA CORNER FILLER SECTION PERLICK TS45D-FI
19 KEC 1 EA BLENDER STATION WITH SINK PERLICK TS12BLW
20 1 NOT USED NOT USED NOT USED
21 NIC 1 EA POINT OF SALE
22 KEC 1 EA STORAGE BIN FOR GLASSWARE PERLICK 7055A-D
23 KEC 1 EA DISPENSING HEAD, WINE PERLICK CM14715
24 KEC 1 EA DISPENSING HEAD, WINE PERLICK CM14715
25 KEC 1 EA DISPENSING HEAD, DRAFT BEER PERLICK 66500-6B
26 KEC 1 EA GLASS CHILLER PERLICK FR24
27 KEC 1 LOT SHELVING, WIRE METRO SEE SPECIFICATIONS
28 KEC 1 EA KEG RACK NEW AGE 31842TT7
29 KEC 1 LOT WALK IN COMBO IMPERIAL MANUFACTURING
30 1 NOT USED NOT USED NOT USED
31 KEC 1 LOT KEG RACK NEW AGE 31842TT7
32 KEC 1 LOT KEG RACK NEW AGE NS475
33 KEC 1 LOT KEG RACK NEW AGE 31842TT7
34 NIC 4 LOT SHELVING, WIRE METRO SEE SPECIFICATIONS
35 1 NOT USED NOT USED NOT USED
36 1 NOT USED NOT USED NOT USED
37 KEC 1 EA REMOTE BEER SYSTEM PERLICK 4410 SEE SPECIFICATIONS
38 KEC 1 EA ICE MAKER FOR BEVERAGE DISPENSER MANITOWOC ICE IB-0696YC
39 KEC 1 EA 320 LB ICE BIN MANITOWOC B-320
40 1 NOT USED NOT USED NOT USED
41 NIC 1 LOT SHELVING, WIRE METRO SEE SPECIFICATIONS
: 1/4" = 1'-0"FS1.0
8 EQUIPMENT PLAN FIRST FLOOR
: 1/2" = 1'-0"FS1.0
7 REMOTE COMPRESSORS
: 3/8" = 1'-0"FS1.0FS1.0
1 COFFEE AND OTHER
24" X 48"
C
24" X 48"
" X
2"
24" X 72"
24" X 36" 24" X 36"
B
A
3 4
ROLL IN
COOLER
MOBILE
HOT
BOXES
TWIN 3 GAL URN
BREWER
34x60 MOBILE S/S TABLE
HAND
SINK
FS1.12
ROLL IN
COOLER
ROLL IN
COOLER
FLOW
FLOW
72" W/T COOLER
MOBILE
HOT
BOXES
ICE
MACHINE
GLASS
RACK
DOLLY
GLASS
RACK
DOLLY
24 X 96 WORK
COUNTER W/SINK
215 217 218
228229
FS1.1
FS1.1 5
FS1.1
213 225
DIV
/23
COORDINATE FINAL
LOCATION WITH
MECH
29.1 38.0
202 203
204 206
DIV
/23
DIV
/23
DIV
/23
209 211 212208226 214
214 215
217216 218
221222 222
1'
0" 4'
6"
2'
0"
ELECTRICAL
OUTLET FOR
ITEM 213
TWIST LOCK
DROP CORD
FROM CEILING
223223 227
2'
0"
KEC
KEC-ALT
OSCI
NIC
FUTURE
DIV 22/23
DIV 26
KITCHEN EQUIPMENT CONTRACTOR
KEC ALTERNATE EQUIPMENT
OWNER SUPPLIED, CONTRACTOR (KEC) INSTALLED
BY OTHERS - NOT IN KEC CONTRACT
FUTURE EQUIPMENT
SEE DIVISION 22/23 - MECHANICAL CONTRACTOR
SEE DIVISION 26 - ELECTRICAL CONTRACTOR
SOURCE LEGEND
LEGEND OF SYMBOLS
ELEVATION MARKER
GENERAL DETAIL MARKER
EQUIPMENT TAG
SHEET
REF. NUMBER
A101
YTEICOSSTNAT
LU
SN
OC
L A
N
OI
T A
N R E T
NI
E
CI
V R
E S
D O
O F
RE
BM
EMLANOISSEFORP
707871
MICHAEL MILES
MEASUREMENTS ON THIS PLAN HAVE BEEN ASSEMBLED BY H-C DESIGN & CONSULTING. HOWEVER NO RESPONSIBILITY FOR THE ACCURACY OF SUCH MEASUREMENTS WILL BE TAKEN BY H-C D&C. ALL UTILIZING THESE PLANS ARE RESPONSIBLE FOR VERIFYING ANY MEASUREMENTS OF THEIR CONCERN. ALL MECHANICAL INFORMATION IS FOR THE SOLE PURPOSE OF IDENTIFYING THE REQUIREMENTS OF THE FOODSERVICE EQUIPMENT AND IS IN NO WAY ENGINEERED BY H-C D&C. H-C DESIGN & CONSULTING ASSUMES NO RESPONSIBILITY FOR CHANGES DICTATED BY AS-BUILT CONDITIONS, EXISTING/ OWNER PROVIDED EQUIPMENT,LOCAL BUILDING CODES, STRUCTURAL CONDITIONS, HEALTH DEPARTMENT, ORDINANCES, AS WELL AS MODIFICATIONS TO THIS PLAN AND WORK PERFORMED BY CONTRACTORS. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING THE GENERAL NOTES AS PART OF THESE PLANS BEFORE WORK IS TO BEGIN. ANY ISSUES, DISCREPANCIES OR INCONSISTENCIES FOUND IN THESE PLANS AND OR WITH LOCAL CODES MUST IMMEDIATELY BE CALLED TO THE ATTENTION OF H-C D&C IN WRITING SO THE APPROPRIATE ACTION CAN BE TAKEN. THESE PLANS AND THEIR CONTENTS ARE THE PROPERTY OF H-C D&C AND MAY ONLY BE REPRODUCED WITH PERMISSION BY H-C DESIGN & CONSULTING.
A R C H I T E C T U R E I N T E R I O R S H I S T O R I C www.aearchitects.com
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 5 9 8 0 2 P H. 4 0 6 . 7 2 1 . 5 6 4 3 F A X. 4 0 6 . 7 2 1 . 1 8 8 7
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 5 9 1 0 1 P H. 4 0 6 . 2 4 8 . 2 6 3 3 F A X. 4 0 6 . 2 4 8 . 2 4 2 7
4 2 8 E A S T M E N D E N H A L L B O Z E M A N, M T 5 9 7 1 5 P H. 4 0 6 . 4 5 3 . 7 3 1 0
PROJECT NO.
NPS PROJ NO.
REVISIONS
DRAWING NO.
PKG
NO.
PKG1
PKG2
PKG3
SHEET
OF
DESIGNED:
CADD:
TECH REVIEW:
DATE
TITLE OF SHEETDRAWING NO.
0 1 2 3 4 5 6 7 8 9 10 inches
189105
/1
/2
:3
:3
P M
15021.00 06.10.2016
FS FLOOR PLAN - PANTRY
MAMMOTH HOTEL SEISMIC
STABILIZATION & REHABILITATION
PHASE I.
YELLOWSTONE NATIONAL PARK, WYOMING
AMT
AMT
MM
06.10.2016
FS1.1
CO
N
ST
RU
C T
IO
N D
O
CU
M
EN
T S
: 1/4" = 1'-0"FS1.1
6 EQUIPMENT PLAN SECOND FLOOR
: 3/8" = 1'-0"FS1.1FS1.1
1 MOP SINK
: 3/8" = 1'-0"FS1.1FS1.1
2 PANTRY NORTH
: 3/8" = 1'-0"FS1.1FS1.1
3 PANTRY - EAST
: 3/8" = 1'-0"FS1.1FS1.1
4 PANTRY ISLAND
: 3/8" = 1'-0"FS1.1FS1.1
5 PANTRY - SOUTH
FOODSERVICE EQUIPMENT SCHEDULE - SECOND FLOOR
ITEM
NO SOURCE QTY UNIT DESCRIPTION MANUFACTURER MODEL
EQUIPMENT
REMARKS
201 KEC 1 LOT SHELVING, WIRE METRO SEE SPECIFICATIONS
202 KEC 1 LOT SHELVING, WIRE METRO SEE SPECIFICATIONS
203 DIV 22/23 1 EA MOP BASIN
204 DIV 22/23 1 EA SERVICE FAUCET FISHER 8253
205 DIV 22/23 1 EA FAUCET, SERVICE SINK FISHER 29556
206 DIV 22/23 1 EA UTILITY SHELF EAGLE GROUP US0824-16/3
207 DIV 22/23 2 EA 4-POLE MOP HOLDER EAGLE GROUP 321561
208 KEC 1 EA HAND SINK EAGLE GROUP HSA-10-1FK
209 KEC 1 EA ROLL IN REFRIGERATOR TRAULSEN RRI132HUT-FHS
210 1 NOT USED NOT USED NOT USED
211 KEC 1 EA ROLL IN REFRIGERATOR TRAULSEN RRI132HUT-FHS
212 KEC 1 EA ROLL IN REFRIGERATOR TRAULSEN RRI132HUT-FHS
213 KEC 1 EA REFRIGERATOR, UNDERCOUNTER TRAULSEN TU072HR
214 KEC 1 LOT SHELVING, WIRE METRO SEE SPECIFICATIONS
215 KEC 1 LOT ENCLOSED WORKTABLE W/OPEN FRONT EAGLE GROUP OB2496SE-BS
216 KEC 2 EA WALL MOUNTED SHELVES EAGLE GROUP WS1260-16/3 CANTELIEVER TO ITEM 215
217 KEC 1 EA COFFEE GRINDER BUNN-O-MATIC G9-2T-HD-0021
218 KEC 1 EA COFFEE URN, AUTOMATIC BUNN-O-MATIC 20500.0000
219 KEC 1 EA 485 LB AIR-COOLED HALF-DICE MANITOWOC ICE IY-0524A
220 1 NOT USED NOT USED NOT USED
221 KEC 1 EA 310 LB ICE BIN MANITOWOC B-420
222 KEC 2 EA CART CRES COR EB-64
223 KEC 2 EA DOLLY, DISHRACK CAMBRO CD2020110
224 KEC 1 EA WORKTABLE-ROLLED EDGE EAGLE GROUP T3660SE
225 KEC 1 EA WARMER, FOOD OVERHEAD HATCO GRA-60
226 KEC 2 EA CORNER GUARD, L-SHAPED FABRICATED
227 KEC 2 LOT BUMPER RAIL FABRICATED
228 KEC 1 LOT SHELVING, WIRE METRO SEE SPECIFICATIONS
229 KEC 1 LOT SHELVING, WIRE METRO SEE SPECIFICATIONS
230 1 NOT USED NOT USED NOT USED
231 KEC 1 EA WARMER, FOOD OVERHEAD HATCO GRA-48
21" X 42"
18" X 42"18" X 42"18" X 42"
NOTE: KITCHEN EQUIPMENT CONTRACTOR TO NOTIFY THE ARCHITECT, IN WRITING, OF ANY DISCREPANCIES DISCOVERED BETWEEN THE WRITTEN SPECIFICATION AND FOODSERVICE DRAWINGS; AWAIT WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH THE ITEMS OR AREAS IN QUESTION PRIOR TO BIDDING OR ORDERING.
KEC
KEC-ALT
OSCI
NIC
FUTURE
DIV 22/23
DIV 26
KITCHEN EQUIPMENT CONTRACTOR
KEC ALTERNATE EQUIPMENT
OWNER SUPPLIED, CONTRACTOR (KEC) INSTALLED
BY OTHERS - NOT IN KEC CONTRACT
FUTURE EQUIPMENT
SEE DIVISION 22/23 - MECHANICAL CONTRACTOR
SEE DIVISION 26 - ELECTRICAL CONTRACTOR
SOURCE LEGEND
T D
CO
AFF
DUPLEX OUTLET - 115 VOLT
CONVENIENCE OUTLET - AT NOTED AFF
SPECIAL CONNECTION - 115 VOLT
SPECIAL CONNECTION - 208 VOLT
ABOVE FINISHED FLOOR
DATA CONNECTION
TEMPERATURE MONITORING CONNECTION
LOW PROFILE PEDESTAL OUTLET - 115V
LOW PROFILE PEDESTAL SPECIAL CONNECTION - 208V
NOTE: ALL OUTLETS TO BE DEDICATED CIRCUITS
NOTE: ALL ABOVE FINISH FLOOR (AFF) MEASUREMENTS
ARE TO THE CENTER OF THE OUTLET
EC TO REVIEW WRITTEN SPECIFICATION MANUAL AS WELL AS THIS
SCHEDULE FOR ELECTRICAL INFORMATION. WRITTEN
SPECIFICATION MANUAL WILL TAKE PRECEDENCE OVER THE
ELECTRICAL SCHEDULE.
FOR SPOT FOODSERVICE CONNECTION PURPOSES ONLY - REFER
TO THE ELECTRICAL SHEETS WITH THE ARCHITECTURAL SET.
F
F
ELECTRICAL SYMBOLS AND ABBREVIATIONS LEGEND
DROP FROM CEILING CONNECTION - 115V
(SEE CEILING DROP POWER DETAIL)
NOTE: ALL OUTLETS CALLED OUT AT 0" AFF TO BE LOW
PROFILE PEDESTAL OUTLET
B
A
C
E1
115/1 - 6.3A
PLUG 5-15P
18" AFF
E7 115/1 - 3.0A
PLUG 5-15P
48" AFF
E8 208/1 - 21.0A
PLUG L6-30P
48" AFF
E2
115/1 - 1.5A
PLUG 5-15P
48" AFF
E3
115.208/1
- 26.0A
DIRECT
48" AFF
E4
115/1 - 9.4A
PLUG 5-15P
48" AFF
E29
115/1 - 8.0A
DIRECT
108" AFF
E37
115/1 - 15.7A
DIRECT
72" AFF
E26 115/1 - 5.8A
PLUG 5-15P
18" AFF
E29.2
115/1 - 1.8A
DIRECT
108" AFF
7' - 3" 1' - 0"
2'
6" 1'
0"
6" 1'
6"
1'
6" 1'
6"
1'
6" 3'
0"
9"
2' - 0" 16' - 7"
4' - 6" 2' - 0" 6' - 2"
CO
48"AFF
CO
48"AFF
3' - 9" 3' - 0" 5' - 8" 2' - 3"
CO
18"AFF
D
D
CO
48"AFF
CO
18"AFF
CO
18"AFF CO
18"AFF
DATA
DATA
3'
6" 2'
2'
2'
0"
E38 115/1 - 1.1A
PLUG 5-15P
54" AFF
CO
18"AFF
E12 115/1 - 3.2A
PLUG 5-15P
18" AFF
CO
18"AFF
DDATA
CO
18"AFF
4'
0"
CO
18"AFF
E29.1 208/1 - 20.0A
REMOTE
0" AFF
E38.0 208/1 - 11.6A
REMOTE
0" AFF
YTEICOSSTNAT
LU
SN
OC
L A
N
OI
T A
N R E T
NI
E
CI
V R
E S
D O
O F
RE
BM
EMLANOISSEFORP
707871
MICHAEL MILES
MEASUREMENTS ON THIS PLAN HAVE BEEN ASSEMBLED BY H-C DESIGN & CONSULTING. HOWEVER NO RESPONSIBILITY FOR THE ACCURACY OF SUCH MEASUREMENTS WILL BE TAKEN BY H-C D&C. ALL UTILIZING THESE PLANS ARE RESPONSIBLE FOR VERIFYING ANY MEASUREMENTS OF THEIR CONCERN. ALL MECHANICAL INFORMATION IS FOR THE SOLE PURPOSE OF IDENTIFYING THE REQUIREMENTS OF THE FOODSERVICE EQUIPMENT AND IS IN NO WAY ENGINEERED BY H-C D&C. H-C DESIGN & CONSULTING ASSUMES NO RESPONSIBILITY FOR CHANGES DICTATED BY AS-BUILT CONDITIONS, EXISTING/ OWNER PROVIDED EQUIPMENT,LOCAL BUILDING CODES, STRUCTURAL CONDITIONS, HEALTH DEPARTMENT, ORDINANCES, AS WELL AS MODIFICATIONS TO THIS PLAN AND WORK PERFORMED BY CONTRACTORS. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING THE GENERAL NOTES AS PART OF THESE PLANS BEFORE WORK IS TO BEGIN. ANY ISSUES, DISCREPANCIES OR INCONSISTENCIES FOUND IN THESE PLANS AND OR WITH LOCAL CODES MUST IMMEDIATELY BE CALLED TO THE ATTENTION OF H-C D&C IN WRITING SO THE APPROPRIATE ACTION CAN BE TAKEN. THESE PLANS AND THEIR CONTENTS ARE THE PROPERTY OF H-C D&C AND MAY ONLY BE REPRODUCED WITH PERMISSION BY H-C DESIGN & CONSULTING.
A R C H I T E C T U R E I N T E R I O R S H I S T O R I C www.aearchitects.com
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 5 9 8 0 2 P H. 4 0 6 . 7 2 1 . 5 6 4 3 F A X. 4 0 6 . 7 2 1 . 1 8 8 7
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 5 9 1 0 1 P H. 4 0 6 . 2 4 8 . 2 6 3 3 F A X. 4 0 6 . 2 4 8 . 2 4 2 7
4 2 8 E A S T M E N D E N H A L L B O Z E M A N, M T 5 9 7 1 5 P H. 4 0 6 . 4 5 3 . 7 3 1 0
PROJECT NO.
NPS PROJ NO.
REVISIONS
DRAWING NO.
PKG
NO.
PKG1
PKG2
PKG3
SHEET
OF
DESIGNED:
CADD:
TECH REVIEW:
DATE
TITLE OF SHEETDRAWING NO.
0 1 2 3 4 5 6 7 8 9 10 inches
189105
/1
/2
:3
:3
P M
15021.00 06.10.2016
FS ELECTRICAL PLAN - BAR
MAMMOTH HOTEL SEISMIC
STABILIZATION & REHABILITATION
PHASE I.
YELLOWSTONE NATIONAL PARK, WYOMING
AMT
AMT
MM
06.10.2016
FS3.0
CO
N
ST
RU
C T
IO
N D
O
CU
M
EN
T S
FOODSERVICE ELECTRICAL SCHEDULE - FIRST FLOOR
ITEM
NO SOURCE QTY UNIT DESCRIPTION AM
PS
KW
AT
TS
H P
VO
LT
S
PH
AS
E
C O
N N
EC
TI
O N
T
YP
E
N
EM
A
EL
EC
TR
IC
AL
A
FF
ELECTRICAL REMARKS
ITEM
NO
1 KEC 1 EA SELF-CONTAINED BACK BAR 3-DOOR
REFRIGERATOR
6.3 0.7 1/3 115 1 PLUG 5-15P 18" 1
2 KEC 1 EA DISPENSER, MILK 1.5 0.2 0.1 115 1 PLUG 5-15P 48" 2
3 KEC 1 EA COFFEE MAKER, AIRPOT 26.0 3.0 115.208 1 DIRECT 48" 3
4 KEC 1 EA COFFEE GRINDER 9.4 1.1 0.75 115 1 PLUG 5-15P 48" 4
7 KEC 2 EA COFFEE GRINDER 3.0 0.3 115 1 PLUG 5-15P 48" 7
8 KEC 1 EA ESPRESSO MACHINE 21.0 4.4 208 1 PLUG L6-30P 48" 8
12 KEC 1 EA BACK BAR 1-DOOR REFRIGERATOR 3.2 0.4 1/5 115 1 PLUG 5-15P 18" 12
26 KEC 1 EA GLASS CHILLER 5.8 0.7 1/3 115 1 PLUG 5-15P 18" 26
29 KEC 1 LOT WALK IN COMBO 8.0 0.9 115 1 DIRECT 108" LIGHTS, CONTROLS AND DOOR HEATER 29
29.1 KEC 1 LOT COOLER CONDENSING UNIT 20.0 4.2 208 1 REMOTE 0" REMOTE CONNECTION 29.1
29.2 KEC 1 LOT COOLER EVAPORATOR UNIT 1.8 0.2 115 1 DIRECT 108" 29.2
37 KEC 1 EA REMOTE BEER SYSTEM 15.7 1.8 0.5 115 1 DIRECT 72" 37
38 KEC 1 EA ICE MAKER FOR BEVERAGE DISPENSER 1.1 0.1 115 1 PLUG 5-15P 54" 38
38.0 KEC 1 EA ICEMAKER CONDENSER, REMOTE 11.6 2.4 1 208 1 REMOTE 0" REMOTE CONNECTION 38.0
: 1/4" = 1'-0"FS3.0
1 ELECTRICAL PLAN FIRST FLOOR
: 1/2" = 1'-0"FS3.0
2 REMOTE COMPRESSORS - ELECTRICAL
24" X 48"
" X
2"
24" X 72"
24" X 36" 24" X 36"
B
A
3 4
E222 115/1 - 13.8A
PLUG 5-15P
18" AFF
E217 115/1 - 9.4A
PLUG 5-15P
48" AFF
E209 115/1 - 10.6A
PLUG 5-15P
84" AFF
E211 115/1 - 10.6A
PLUG 5-15P
84" AFF
E212 115/1 - 10.6A
PLUG 5-15P
84" AFF
E218 115.208/1
- 28.0A
DIRECT
48" AFF
E222 115/1 - 13.8A
PLUG 5-15P
18" AFF
E219 115/1 - 11.5A
PLUG 5-15P
60" AFF
115/1 - 6.9A
DIRECT
48" AFF
E231
1' - 8" 3' - 9" 1' - 4" 3' - 3" 1' - 6" 2' - 9" 2' - 9" 2' - 0"
4'
3'
0" 3'
0"
2'
0" 1'
4"
9" 11' - 2"
D R
O P
FR
O
M C
EI
LI
N G
CO
48"AFF
CO
18"AFF
CO
18"AFF
CO
18"AFF
2' - 8"
3'
6"3' - 0 1/2"
CO
18"AFF
5'
0" 2'
0"
2'
0" 1'
3"
CO
18"AFF
CO
18"AFF
CO
18"AFF
115/1 - 8.8A
DIRECT
48" AFF
E225
D R
O P
FR
O
M C
EI
LI
N G
ROUTE POWER
THROUGH SHELF
115/1 - 8.3A
PLUG 5-15P
18" AFF
E213
CO
48"AFF
CO
48"AFF
CO
48"AFF
CO
48"AFF
D
DATA
CO
48"AFF
CO
18"AFF
NOTE: KITCHEN EQUIPMENT CONTRACTOR TO NOTIFY THE ARCHITECT, IN WRITING, OF ANY DISCREPANCIES DISCOVERED BETWEEN THE WRITTEN SPECIFICATION AND FOODSERVICE DRAWINGS; AWAIT WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH THE ITEMS OR AREAS IN QUESTION PRIOR TO BIDDING OR ORDERING.
T D
CO
AFF
DUPLEX OUTLET - 115 VOLT
CONVENIENCE OUTLET - AT NOTED AFF
SPECIAL CONNECTION - 115 VOLT
SPECIAL CONNECTION - 208 VOLT
ABOVE FINISHED FLOOR
DATA CONNECTION
TEMPERATURE MONITORING CONNECTION
LOW PROFILE PEDESTAL OUTLET - 115V
LOW PROFILE PEDESTAL SPECIAL CONNECTION - 208V
NOTE: ALL OUTLETS TO BE DEDICATED CIRCUITS
NOTE: ALL ABOVE FINISH FLOOR (AFF) MEASUREMENTS
ARE TO THE CENTER OF THE OUTLET
EC TO REVIEW WRITTEN SPECIFICATION MANUAL AS WELL AS THIS
SCHEDULE FOR ELECTRICAL INFORMATION. WRITTEN
SPECIFICATION MANUAL WILL TAKE PRECEDENCE OVER THE
ELECTRICAL SCHEDULE.
FOR SPOT FOODSERVICE CONNECTION PURPOSES ONLY - REFER
TO THE ELECTRICAL SHEETS WITH THE ARCHITECTURAL SET.
F
F
ELECTRICAL SYMBOLS AND ABBREVIATIONS LEGEND
DROP FROM CEILING CONNECTION - 115V
(SEE CEILING DROP POWER DETAIL)
NOTE: ALL OUTLETS CALLED OUT AT 0" AFF TO BE LOW
PROFILE PEDESTAL OUTLETKEC
KEC-ALT
OSCI
NIC
FUTURE
DIV 22/23
DIV 26
KITCHEN EQUIPMENT CONTRACTOR
KEC ALTERNATE EQUIPMENT
OWNER SUPPLIED, CONTRACTOR (KEC) INSTALLED
BY OTHERS - NOT IN KEC CONTRACT
FUTURE EQUIPMENT
SEE DIVISION 22/23 - MECHANICAL CONTRACTOR
SEE DIVISION 26 - ELECTRICAL CONTRACTOR
SOURCE LEGEND
YTEICOSSTNAT
LU
SN
OC
L A
N
OI
T A
N R E T
NI
E
CI
V R
E S
D O
O F
RE
BM
EMLANOISSEFORP
707871
MICHAEL MILES
MEASUREMENTS ON THIS PLAN HAVE BEEN ASSEMBLED BY H-C DESIGN & CONSULTING. HOWEVER NO RESPONSIBILITY FOR THE ACCURACY OF SUCH MEASUREMENTS WILL BE TAKEN BY H-C D&C. ALL UTILIZING THESE PLANS ARE RESPONSIBLE FOR VERIFYING ANY MEASUREMENTS OF THEIR CONCERN. ALL MECHANICAL INFORMATION IS FOR THE SOLE PURPOSE OF IDENTIFYING THE REQUIREMENTS OF THE FOODSERVICE EQUIPMENT AND IS IN NO WAY ENGINEERED BY H-C D&C. H-C DESIGN & CONSULTING ASSUMES NO RESPONSIBILITY FOR CHANGES DICTATED BY AS-BUILT CONDITIONS, EXISTING/ OWNER PROVIDED EQUIPMENT,LOCAL BUILDING CODES, STRUCTURAL CONDITIONS, HEALTH DEPARTMENT, ORDINANCES, AS WELL AS MODIFICATIONS TO THIS PLAN AND WORK PERFORMED BY CONTRACTORS. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING THE GENERAL NOTES AS PART OF THESE PLANS BEFORE WORK IS TO BEGIN. ANY ISSUES, DISCREPANCIES OR INCONSISTENCIES FOUND IN THESE PLANS AND OR WITH LOCAL CODES MUST IMMEDIATELY BE CALLED TO THE ATTENTION OF H-C D&C IN WRITING SO THE APPROPRIATE ACTION CAN BE TAKEN. THESE PLANS AND THEIR CONTENTS ARE THE PROPERTY OF H-C D&C AND MAY ONLY BE REPRODUCED WITH PERMISSION BY H-C DESIGN & CONSULTING.
A R C H I T E C T U R E I N T E R I O R S H I S T O R I C www.aearchitects.com
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 5 9 8 0 2 P H. 4 0 6 . 7 2 1 . 5 6 4 3 F A X. 4 0 6 . 7 2 1 . 1 8 8 7
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 5 9 1 0 1 P H. 4 0 6 . 2 4 8 . 2 6 3 3 F A X. 4 0 6 . 2 4 8 . 2 4 2 7
4 2 8 E A S T M E N D E N H A L L B O Z E M A N, M T 5 9 7 1 5 P H. 4 0 6 . 4 5 3 . 7 3 1 0
PROJECT NO.
NPS PROJ NO.
REVISIONS
DRAWING NO.
PKG
NO.
PKG1
PKG2
PKG3
SHEET
OF
DESIGNED:
CADD:
TECH REVIEW:
DATE
TITLE OF SHEETDRAWING NO.
0 1 2 3 4 5 6 7 8 9 10 inches
189105
/1
/2
:3
:3
P M
15021.00 06.10.2016
FS ELECTRICAL PLAN - PANTY
MAMMOTH HOTEL SEISMIC
STABILIZATION & REHABILITATION
PHASE I.
YELLOWSTONE NATIONAL PARK, WYOMING
AMT
AMT
MM
06.10.2016
FS3.1
CO
N
ST
RU
C T
IO
N D
O
CU
M
EN
T S
: 1/4" = 1'-0"FS3.1
1 ELECTRICAL PLAN SECOND FLOOR
FOODSERVICE ELECTRICAL SCHEDULE - SECOND FLOOR
ITEM
NO SOURCE QTY UNIT DESCRIPTION AM
PS
KW
AT
TS
H P
VO
LT
S
PH
AS
E
C O
N N
EC
TI
O N
T
YP
E
N
EM
A
EL
EC
TR
IC
AL
A
FF
ELECTRICAL REMARKS
ITEM
NO
209 KEC 1 EA ROLL IN REFRIGERATOR 10.6 1.2 115 1 PLUG 5-15P 84" 209
211 KEC 1 EA ROLL IN REFRIGERATOR 10.6 1.2 115 1 PLUG 5-15P 84" 211
212 KEC 1 EA ROLL IN REFRIGERATOR 10.6 1.2 115 1 PLUG 5-15P 84" 212
213 KEC 1 EA REFRIGERATOR, UNDERCOUNTER 8.3 1.0 115 1 PLUG 5-15P 18" CONNECTION ON ITEM 224 213
217 KEC 1 EA COFFEE GRINDER 9.4 1.1 0.75 115 1 PLUG 5-15P 48" 217
218 KEC 1 EA COFFEE URN, AUTOMATIC 28.0 3.2 115.208 1 DIRECT 48" THREE (3) WIRE PLUS GROUND 218
219 KEC 1 EA 485 LB AIR-COOLED HALF-DICE 11.5 1.3 115 1 PLUG 5-15P 60" 219
222 KEC 2 EA CART 13.8 1.6 0 115 1 PLUG 5-15P 18"…