Hazmat_Survey_Compiled_-_FOVA_987-404.pdf

PDF 3 MB Posted

Attached to
Rehabilitate Buildings and Phase 1 Utilities at Fort Vancouver National Historic Site, Washington FOVA 174962
Solicitation number
P15PS00118
Issued by

About this file

FOVA 174962 - Hazmat Survey Compiled - FOVA 987-404

View the file

Other files

File Type Posted
0_-_Amend_6_-_P15PS00118_-_FOVA_174962_SF30.pdf PDF
2_-_Amend__6_FOVA_Section_028213-_ASBESTOS_spec_revised_FINAL.pdf PDF
1_-_Amend_6__FOVA_Section_02_8319__LEAD-BASED_PAINT_spec_FINAL.pdf PDF
3_-_Amend_6_FOVA_174962_Q-A_responses.pdf PDF
0_-_Amend_5_-_P15PS00118_-_FOVA_174962_SF30.pdf PDF
4_-_Amend_5_FOVA_Questions.pdf PDF
3_-_Amend_5_FOVA_Site_Visit_Sign_in_Sheets_3-25.pdf PDF
2_-_ACM_Quantity_Estimates_FOVA_174962_.pdf PDF
1_-_Final_ACM_HazMat_SurveySummary_FOVA_041414KMA.PDF PDF
2__-_Amendment_4_FOVA_Questions.pdf PDF
0_-_Amend_4_-_P15PS00118_-_FOVA_174962_SF30.pdf PDF
1_-_Amendment_4_Attachment_1_FOVA_174962_.pdf PDF
2__-_Amendment_3_FOVA_Questions_3-13-15.pdf PDF
1_-_Amend_3_Attachment_1_FOVA__174962.pdf PDF
Past_Performance_Questionnaire_x_(1).doc DOC document
0_-_Amend_3_-_P15PS00118_-_FOVA_174962_SF30.pdf PDF
3_-Amendment_3_FOVA_Questions_3-16-15.pdf PDF
3_-_Amend_2_Attachment_1_FOVA_174962_pre_bid_list_of_attendees.pdf PDF
6_-Sustainability_Checklist_LEED_2009_FOVA_9-24-14.pdf PDF
4_-_Amend_2_Attachment_2_FOVA_174962.pdf PDF
1_-_Amend_1_-_P15PS00118_-_FOVA_174962_SF30.pdf PDF
2_-_Amend_2_Revised_SF_1442.pdf PDF
0_-_Amend_2_-_P15PS00118_-_FOVA_174962_SF30.pdf PDF
5_-_Amend_2_FOVA_Questions_3-10-15.pdf PDF
Amend_1_-_Revised_Contract_Clauses_-_FOVA_174962.pdf PDF
Amend_1_-_Attachment_2_-_SECTION_01_27_00_Phase_1.pdf PDF
Amend_1__-_Attachment_1_-_FOVA_174962_.pdf PDF
Drawings_No._389_126929.pdf PDF
Drawing_No._389_119939.pdf PDF
FOVA__Proposal_Submission_Package_x.pdf PDF
Drawing_No._389_126282.pdf PDF
Project_Specs_Bldgs_987-404_for_USFS_Vol_2.pdf PDF
Supplemental_993_pics.pdf PDF
Drawing_No._389_105548_vol_1.pdf PDF
FOVA_Request_for_Proposal.pdf PDF
FOVA_Lead_Base_Paint_and_AHERA_Inspection__Amend_2_Clarification_to_report_questions.pdf PDF
Drawing_No._389_105548_vol_2.pdf PDF
Project_Specs_Rehabilitate_Utilities_and_Infrastructure_in_East_and_South_Vancouver_Barracks.pdf PDF
Drawing_No._389_80038A.pdf PDF
Wage_Rates_WA_-_2-12-2015.pdf PDF
Project_Specs_Bldgs_987-404_for_USFS_Vol_1.pdf PDF
Supplemental_989_pics.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

White Shield, Inc.

Progressive Solutions -Traditional Values

Surveying Environmental Quality Control

320 N. 20th Avenue, Pasco, WA 99301 www.whiteshield.com Phone (509) 547-0100 Fax (509) 547-8292

Karen Davis Smith November 14, 2011 Jones and Jones Architects 105 South Main Street, Suite 300 Seattle, WA 98104-3444

RE: Fort Vancouver Lead Based Paint and AHERA Inspection

Addendum 1: limitations of access

Karen, During our site visit and lead based paint inspection we were unable to access several rooms. Due to this limitation of access, White Shield performed the most comprehensive report possible. Due to the conflict of our arrival to test and the Army moving out of the building, all rooms and areas were not accessible to the White Shield’s testing crew. All paint conditions and exact measurements must be performed by the contractor hired to perform the abatement and stabilization of Bldg 987.

Included is a list of rooms that were not accessible:

Basement: Wing 2- Rooms 51, 52, 61.

Level 1: Wing 1-Rm 162 and Rm-155, Wing 2-Rm 169, Wing 3-Rm 109A

Level 2: Wing-3 Rooms 209 and 212.

Thank you, Jessica Morales, Project Manager

White Shield, Inc. Progressive Solutions -Traditional Values

Surveying • Mapping • Environmental

320 N. 20th Avenue, Pasco, WA 99301 www.whiteshield.com Phone (509) 547-0100 Fax (509) 547-8292

October 21, 2011

Karen Davis Smith Jones and Jones Architects 105 South Main Street, Suite 300 Seattle, WA 98104-3444

RE: Fort Vancouver Good Faith Asbestos and Lead Inspection

On September 6th, 7th & 8th of 2011 I, Roxanne Bradshaw, Faith Preston and Raymond Miller of White Shield Environmental performed a good faith asbestos survey and Lead inspection of the following:

Building 404 and Building 987 at Fort Vancouver in Vancouver, WA

Building 404:

Description: Four bay, two story garage.

Exterior: Brick, metal windows and composition with mastic roofing.

Rooms: Office, Dispatch Room, Battery Room, 2 Storage Areas (fence walls), Janitor Closet, Men’s and Women’s Restroom and Lube Room (access only from exterior of building).

Office and Dispatch: Wood doors, 1’ x 1’ floor tile, ceiling tiles with mastic dots, pink insulation, cove base and plaster walls.

Battery Room: Brick walls, metal door and chemical wash station.

Storage Areas: Located in back corners; brick walls and fence interior walls.

Janitor Closet: Brick walls and porcelain drain.

Men’s and Women’s Restroom: Brick walls, 1” x 1” blue tile on floor and trim on walls.

Lube Room: Brick walls and pipes.

Bays: Brick walls, large insulation board and ducting.

Building 987:

Description: Horseshoe shaped building, 4 floors (includes basement and attic). No access to attic due to restrictions from military. *Note: We separated each floor into wings (west side:

wing 1, central: wing 2 and east side: wing 3).

320 N. 20th Avenue, Pasco, WA 99301 www.whiteshield.com Phone (509) 547-0100 Fax (509) 547-8292

Exterior: Wood Siding, composition roofing with mastic around penetrations and wood windows with putty.

Basement:

Wing 1: Includes a mail room, women’s restroom, men’s locker room with showers, and furnace room with 3 adjoining storage rooms.

Floors: 1’ x 1’ floor tile and concrete foundation throughout.

Walls: Brick and rock mostly on exterior walls, sheet rock and plaster and 1’ x 1’ acoustic tile.

Ceilings: Standard acoustic tile, sheetrock/plaster and open ceilings with wood structural beams.

Misc. Materials: Formica on counters in mail room and restrooms. Piping exposed on ceiling throughout basement (some marked as asbestos containing wrap and some marked without.)

Piping in furnace room not marked and the same materials found in furnace room in wing 3.

Wing 2: Includes 2 locked rooms we were not allowed accesses to. 1 room we were allowed limited access to and a room labeled the “cubby hole” that had cabinets with a sink and an adjoining storage room. Also stairways that led to the first floor on both the west and east sides.

Floors: Concrete foundation throughout.

Walls: Brick and rock mostly on exterior walls, sheet rock and plaster.

Ceilings: Sheetrock/plaster, and open ceilings with wood.

Misc. Materials: Piping exposed on ceiling throughout basement (some marked as asbestos containing wrap and some marked without.) Vinyl stair tread, pergo and 1’ x 1’ tile on stairs.

Wing 3: Includes furnace room, large conference room, 3 offices, telecom room, storage room and stairwell leading to 1st floor.

Floors: Concrete foundation throughout, 1’ x 1’ floor tile and carpet found.

Walls: Brick and rock mostly on exterior walls, bare wood, sheet rock and plaster and 1’ x 1’ acoustic tile.

Ceilings: Standard acoustic tile, 1’ x 1’ acoustic tile, sheetrock/plaster and open ceilings with wood.

Misc. Materials: Piping exposed on ceiling throughout basement (some marked as asbestos containing wrap and some marked without.) Piping in furnace room not marked and the same materials found in furnace room in wing 1.

320 N. 20th Avenue, Pasco, WA 99301 www.whiteshield.com Phone (509) 547-0100 Fax (509) 547-8292

First Floor:

Wing 1: Includes 8 offices, a copy room, large connecting hallway and large conference room.

Floors: Carpet and 1’ x 1’ floor tile.

Walls: Sheet rock and plaster and 1’ x 1’ acoustic tile.

Ceilings: Standard acoustic tile, sheetrock/plaster and molded tin on ceiling.

Misc. Materials: Formica on counters in mail room and restrooms and cove base.

Wing 2: Includes 10 offices and 2 stairwells that lead down to basement and up to 2nd floor.

Floors: 1’ x 1’ floor tile and carpet.

Walls: Sheet rock and plaster.

Ceilings: Sheetrock/plaster, and tin ceilings.

Misc. Materials: Vinyl tread on stairways and cove base.

Wing 3: Includes 12 offices connected by a large hallway and a large area split into several spaces with partition walls.

Floors: 1’ x 1’ floor tile throughout (small patch of blue).

Walls: Sheet rock, plaster, small patches of wallpaper, plywood and wood paneling.

Ceilings: Molded tin ceiling and sheetrock/plaster.

Misc. Materials: Metal covering the brick chimney and cove base.

Second Floor:

Wing 1: Includes 16 offices and a large hallway connecting all.

Floors: 1’ x 1’ floor tile throughout.

Walls: Sheet rock and plaster.

Ceilings: Sheetrock/plaster.

Misc. Materials: Cove base.

Wing 2: Includes 5 offices, men’s restroom and women’s locker room with shower and a break room.

320 N. 20th Avenue, Pasco, WA 99301 www.whiteshield.com Phone (509) 547-0100 Fax (509) 547-8292

Floors: 1’ x 1’ floor tile and carpet.

Walls: Sheet rock, plaster, wall paper and 1’ x 1’ acoustic tile.

Ceilings: Standard acoustic tile and sheetrock/plaster.

Misc. Materials: Formica on counters in restrooms and cove base.

Wing 3: Includes 11offices and a large hallway connecting all.

Floors: Carpet throughout.

Walls: Sheet rock and plaster and carpet.

Ceilings: Sheetrock/plaster.

Misc. Materials: Cove base.

Field inspection, data collection, and report were based on the following scope of work:

Asbestos Containing Materials (ACM)

Bulk sampling of suspect ACM.

Analysis of suspect ACM by NVLAP accredited laboratory.

Identify ACM to be removed prior to demolition or renovation.

The survey was based on “visible and accessible materials” and although reasonable effort was made to locate and test suspect materials, some suspect materials may remain hidden in walls or below floor underlayment or other areas until demolition or renovation work makes them accessible. Materials uncovered during the course of demolition, renovation, or maintenance activities that are not identified in this report must be presumed to contain asbestos or other hazardous materials until proper analysis proves otherwise.

Sampling of suspect asbestos-containing materials were conducted as prescribed in Title 40 Code of Regulations (40 CFR) 763.86. Sampling methodology used in accordance to Puget Sound Clean Air Agency, Regulation 111, Article 4. Also, the owner is meeting the “Good Faith” inspection requirement defined in WAC 296-62-07721 (Hazcom to Employees). In addition 40 CFR, subpart M, Section 61.141, establishes the allowable limit of asbestos in building materials at 1% by weight. Materials more than 1% are regulated and must be handled in accordance with all federal, state and local regulations.

Notes, pictures and observations of bulk samples were recorded at the time of collection.

Note: Quantities were not performed due to time constraints. The Abatement company hired to perform the abatement work will need to field verify quantities.

320 N. 20th Avenue, Pasco, WA 99301 www.whiteshield.com Phone (509) 547-0100 Fax (509) 547-8292

Summary of ACM findings:

Floor 1: Wing 3 Sample 13 ~ 10% Chrysotile in the black mastic only. 1’x1’ tile associated with the mastic will be considered Asbestos due to the mastic used to adhere it to the floor.

Basement: Wing 3 Sample 5 ~ 10% Chrysotile. TSI.

320 N. 20th Avenue, Pasco, WA 99301 www.whiteshield.com Phone (509) 547-0100 Fax (509) 547-8292

Basement: Wing 3 Sample 7 ~ 90% Chrysotile. TSI.

Basement: Wing 3 Sample 9 ~ 80% Chrysotile. TSI.

Required Action: All Thermal system insulation-pipe wrap and associated elbow wraps identified in the pictures and lab results are classified as Class 1 friable materials. All asbestos identified above, must be removed prior to disturbance from remodeling or demolition activities.

320 N. 20th Avenue, Pasco, WA 99301 www.whiteshield.com Phone (509) 547-0100 Fax (509) 547-8292

The black mastic associated with the vinyl floor tile located on the 1st floor in wing 3 is considered non-friable asbestos and may be left in place or removed prior to renovation activities. If the vinyl tile is to be removed, it must be considered contaminated with asbestos mastic and disposed of according to the local Clean air agencies regulations. If such future remodeling disturbs the flooring material, it could be rendered friable under certain circumstances. See WRD 23.30 for Labor & Industries instructions for joint compound in wall board systems.

The asbestos company hired for the abatement must decontaminate the effected areas and provide air samples to prove the area has been cleared of all airborne asbestos fibers. Prior to the abatement of asbestos, a pre abatement air sample must be performed by the asbestos company or consultant, to determine the quantity of asbestos fibers in the air.

In most cases, there is a 10 day waiting period required to notify The Local Clean Air Agency and Labor & Industries prior to the start of any asbestos project. The work must be performed by a licensed asbestos contractor. The above named agencies determine if a project qualifies for an emergency notification.

During renovation and/or demolition if any other suspect material is uncovered, that is not included in this report, work must cease until the material has been tested for Asbestos. Please see the links below for instructions on the regulations and rules that govern both asbestos and demolition in residential housing. The attic, locked rooms and wall cavities were not inspected, and are excluded from this report.

Regulations and Notifications:

For removal of wall systems with Asbestos joint compound:

http://www.lni.wa.gov/safety/rules/policies/pdfs/wrd2330.pdf

Labor and Industries Notification Information for Asbestos Contractors:

http://www.lni.wa.gov/FormPub/Detail.asp?DocID=1717

For instructions on GWB wall Board Systems with ACM Joint Compound:

http://www.lni.wa.gov/safety/rules/policies/pdfs/wrd2330.pdf

Glossary of definitions:

ACM: Asbestos Containing Material PACM: Presumed Asbestos Containing Material L&I: Labor and Industries AHERA: Asbestos Hazard Emergency Response Act WISHA: The Washington Industrial Safety and Health Act WRD: WISHA Regional Directive HAZCOM: Hazardous Communications GWB: Gypsum wall board VAT: Vinyl Asbestos Tile TSI: Thermal Systems Insulation

Graph of all PLM Samples

Sample Sheet 1 Sample # Materials & Description Location Type Friable Condition Asbestos Date

Good No 8‐SepW‐1 S‐9 Sheet Rock‐Joint Compound Basement: Hall B‐Wall B JC Yes

W‐1 S‐2

No 8‐Sep

8‐SepNo

W‐1 S‐1 Sheet Rock‐Surfacing Basement: Shower‐Wall

E Surfacing Yes Good

GoodYesJC Basement: Shower‐Wall

E Sheet Rock‐Joint Compound

W‐1 S‐4

No 8‐Sep

8‐SepNo

W‐1 S‐3 Formica Basement: Latrine‐Wall

B misc No Good

GoodNomisc Basement: Mail Room

Counter Formica

W‐1 S‐6

No 8‐Sep

8‐SepNo

W‐1 S‐5 Sheet Rock‐Surfacing Basement: Room 53‐

Wall B Surfacing Yes Good

GoodYesJC Basement: Room 53‐

Wall B Sheet Rock‐Joint Compound

W‐1 S‐8

No 8‐Sep

8‐SepNo

W‐1 S‐7 Plaster Basement: Under Stairs Surfacing Yes Good

GoodYesSurfacingBasement: Hall B‐Wall BSheet Rock‐Surfacing

Sample Sheet 2

W‐2 S‐6 Sheet Rock‐Surfacing Basement: Room 3‐Wall

D2 Surfacing Yes Good No 8‐Sep

W‐2 S‐5 Sheet Rock‐Surfacing Basement: Room 3‐Wall

B2 Surfacing Yes Good No 8‐Sep

W‐2 S‐4 Pergo flooring Basement: Stairs A Misc No Good No 8‐Sep

W‐2 S‐3 Formica Basement: Room 3‐Wall

B2 Misc No Good No 8‐Sep

W‐2 S‐2 Sheet Rock‐Joint Compound Basement: Room 3‐Wall

D2 JC Yes Good No 8‐Sep

W‐2 S‐1 Sheet Rock‐Joint Compound Basement: Room 3‐Wall

B2 Surfacing Yes Good No 8‐Sep

Sample Sheet 3

W‐3 S‐11 Sheet Rock‐Joint Compound Basement: Room 8‐Wall

D2 JC Yes Good No 8‐Sep

W‐3 S‐10 Sheet Rock‐Surfacing Basement: Room 8‐Wall

D2 Surfacing Yes Good No 8‐Sep

W‐3 S‐9 Pipe Wrap Basement: Room 1‐

Ceiling TSI Yes Good Yes‐80% 8‐Sep

W‐3 S‐8 White Patching Material Basement: Room 1‐

Ceiling TSI Yes Good No 8‐Sep

W‐3 S‐7 Pipe Wrap‐Heavy Canvas Basement: Room 1‐

Furnace TSI Yes Good Yes‐90% 8‐Sep

W‐3 S‐6 White Tape on Pipe Basement: Room 1‐

Ceiling TSI YES Good No 8‐Sep

W‐3 S‐5 Pipe Wrap with Silver Paint Basement: Room 1‐

Ceiling TSI Yes Good Yes‐10% 8‐Sep

W‐3 S‐4 1 x 1 Brown Floor Tile Basement: Room 2‐

Floor Misc. No Good No 8‐Sep

W‐3 S‐3 Cement Board Basement: Room 2‐Wall

C Misc. Yes Good No 8‐Sep

W‐3 S‐2 1 x1 Acustic Tile Basement: Room 2‐

Ceiling Misc. Yes Good No 8‐Sep

W‐3 S‐1 Mastic Dots Basement: Room 2‐

Ceiling Misc. No Good No 8‐Sep

Sample Sheet 4

W‐1 S‐9 Stair Tread First Floor: Stairwell B Misc No Good No 7‐Sep

W‐1 S‐8 Joint Compound First Floor: Room 101‐

Ceiling JC Yes Good No 7‐Sep

W‐1 S‐7 Sheet Rock‐Joint Compound First Floor: Hall JC Yes Good No 7‐Sep

W‐1 S‐6 Sheet Rock‐Surfacing First Floor: Hall Surfacing Yes Good No 7‐Sep

W‐1 S‐5 Sheet Rock‐Joint Compound First Floor: Room 101‐

Wall D JC Yes Good No 7‐Sep

W‐1 S‐4 Sheet Rock‐Surfacing First Floor: Room 101‐

Wall D Surfacing Yes Good No 7‐Sep

W‐1 S‐3 Cove Base First Floor: Room 101‐

Wall D Misc No Good No 7‐Sep

W‐1 S‐2 Plaster First Floor: Room 101‐

Wall B Surfacing Yes Good No 7‐Sep

W‐1 S‐1 Plaster First Floor: Room 101‐

Wall B Surfacing Yes Good No 7‐Sep

Sample Sheet 5

W‐2 S‐7 Plaster First Floor: Office 7 Wall

B Surfacing Yes Good No 7‐Sep

W‐2 S‐6 Sheet Rock‐Joint Compound First Floor: Office 6 Wall

C JC Yes Good No 7‐Sep

W‐2 S‐5 Sheet Rock‐Surfacing First Floor: Office 6 Wall

C Surfacing Yes Good No 7‐Sep

W‐2 S‐4 Plaster First Floor: Office 3‐Wall

A Surfacing No Good No 7‐Sep

W‐2 S‐3 Sheet Rock‐Surfacing First Floor: Office 4‐Wall

D Surfacing No Good No 7‐Sep

W‐2 S‐2 Plaster First Floor: Office 5‐Wall

D Surfacing Yes Good No 7‐Sep

W‐2 S‐1 Sheet Rock‐Surfacing First Floor: Office 4‐Wall

D Surfacing Yes Good No 7‐Sep

Sample Sheet 6

W‐3 S‐13 1 x 1 Floor Tile First Floor: Floor Misc No Good Yes‐10% 7‐Sep

W‐3 S‐12 Wall Paper First Floor Misc No Good No 7‐Sep

W‐3 S‐11 Blue 1 x 1 Floor Tile First Floor Misc No Good No 7‐Sep

W‐3 S‐10 Wall Paper First Floor Misc No Good No 7‐Sep

W‐3 S‐9 Wall Paper First Floor Misc No Good No 7‐Sep

W‐3 S‐8 Sheet Rock‐Joint Compound First Floor JC Yes Good No 7‐Sep

W‐3 S‐7 Sheet Rock‐Joint Compound First Floor JC Yes Good No 7‐Sep

W‐3 S‐6 Sheet Rock‐Surfacing First Floor Surfacing Yes Good No 7‐Sep

W‐3 S‐5 Sheet Rock‐Joint Compound First Floor JC Yes Good No 7‐Sep

W‐3 S‐4 Sheet Rock‐Surfacing First Floor Surfacing Yes Good No 7‐Sep

W‐3 S‐3 Sheet Rock‐Surfacing First Floor Surfacing Yes Good No 7‐Sep

W‐3 S‐2 Plaster First Floor Surfacing Yes Good No 7‐Sep

W‐3 S‐1 Plaster First Floor Surfacing Yes Good No 7‐Sep

Sample Sheet 7

W‐1 S‐12 Cove Base Second Floor: Room 259

Wall A Misc No Good No 6‐Sep

W‐1 S‐11 Plaster Second Floor: Hall B

Wall D Surfacing Yes Good No 6‐Sep

W‐1 S‐10 Sheet Rock‐Joint Compound Second Floor: Hall B

Wall C JC Yes Good No 6‐Sep

W‐1 S‐9 Sheet Rock‐Surfacing Second Floor: Hall B

Wall C Surfacing Yes Good No 6‐Sep

W‐1 S‐8 Sheet Rock‐Joint Compound Second Floor: Room 272

Wall A JC Yes Good No 6‐Sep

W‐1 S‐7 Sheet Rock‐Surfacing Second Floor: Room 272

Wall A Surfacing Yes Good No 6‐Sep

W‐1 S‐6 Sheet Rock‐Joint Compound Second Floor: Room 267

Wall D JC Yes Good No 6‐Sep

W‐1 S‐5 Sheet Rock‐Surfacing Second Floor: Room 267

Wall D Surfacing Yes Good Yes‐<1% 6‐Sep

W‐1 S‐4 Sheet Rock‐Surfacing Second Floor: Room 273

Wall D Surfacing Yes Good No 6‐Sep

W‐1 S‐3 Wall Paper Second Floor: Room 273

Wall D Misc No Good No 6‐Sep

W‐1 S‐2 1 x 1 Floor Tile Second Floor: Room 270

Floor Misc No Fair No 6‐Sep

W‐1 S‐1 Plaster Second Floor: Room 270

Wall C Surfacing Yes Good No 6‐Sep

Sample Sheet 8

W‐2 S‐15 Plaster Second Floor:

C430Womans Bath‐Wall Surfacing Yes Good No 6‐Sep

W‐2 S‐14 Plaster Second Floor: Room 254‐

Wall B Surfacing Yes Good No 6‐Sep

W‐2 S‐13 Plaster Second Floor: Break

Room‐Wall A Surfacing Yes Good No 6‐Sep

W‐2 S‐12 Vinyl Tile Second Floor: Break

Room‐Wall F Misc No Good No 6‐Sep

W‐2 S‐11 Wall Paper Second Floor: Break

Room‐Wall A Misc No Good No 6‐Sep

W‐2 S‐10 Formica Second Floor: Break

Room‐Sink Misc No Good No 6‐Sep

W‐2 S‐9 Formica Second Floor: Mens

Bath‐Sink Misc No Good No 6‐Sep

W‐2 S‐8 Sheet Vinyl Second Floor: Womans

Bath‐Wall D Misc Yes Good No 6‐Sep

W‐2 S‐7 Cove Base Second Floor: Womans

Bath‐Wall D Misc No Good No 6‐Sep

W‐2 S‐6 Sheet Rock‐Joint Compound Second Floor: Room 252‐

Wall A Misc Yes Good No 6‐Sep

W‐2 S‐5 Sheet Rock‐Surfacing Second Floor: Room 252‐

Ceiling Surfacing Yes Good No 6‐Sep

W‐2 S‐4 Acoustic Tile Second Floor: Room 204‐

Ceiling Misc Yes Good No 6‐Sep

W‐2 S‐3 Acoustic Tile Second Floor: Room 203‐

Wall D Misc Yes Good No 6‐Sep

W‐2 S‐2 Wall Paper Second Floor: Room 254‐

Wall D Misc No Good No 6‐Sep

W‐2 S‐1 Cove Base Brown Second Floor: Room 202‐

Wall B Misc No Good No 6‐Sep

Sample Sheet 9

W‐3 S‐15 Cove Base Second Floor: Stair Well Misc No Good No 6‐Sep

W‐3 S‐14 Plaster Second Floor: Room 209‐

Wall C Surfacing Yes Good No 6‐Sep

W‐3 S‐13 Sheet Rock‐Joint Second Floor: Room 214‐

Wall C JC Yes Good No 6‐Sep

W‐3 S‐12 Sheet Rock‐Joint Second Floor: Room 208‐

Wall A JC Yes Good No 6‐Sep

W‐3 S‐11 Sheet Rock‐Surfacing Second Floor: Room 208‐

Wall A Surfacing Yes Good No 6‐Sep

W‐3 S‐10 Sheet Rock‐Joint Second Floor: Hall A‐

Wall A JC Yes Good No 6‐Sep

W‐3 S‐9 Sheet Rock‐Surfacing Second Floor: Hall A‐

Wall A Surfacing Yes Good No 6‐Sep

W‐3 S‐8 Cove Base Second Floor: Room 200‐

Wall C Misc No Good No 6‐Sep

W‐3 S‐7 Carpet & Glue Second Floor: Room 200‐

Wall F Misc No Good No 6‐Sep

W‐3 S‐6 Carpet & Glue Second Floor: Room 200‐

Wall C Misc No Good No 6‐Sep

W‐3 S‐5 Wall Paper Second Floor: Room 222‐

Wall A Misc No Good No 6‐Sep

W‐3 S‐4 Wall Paper Second Floor: Room 218‐

Wall C Misc No Good No 6‐Sep

W‐3 S‐3 Wall Paper Second Floor: Room 211‐

Wall D Misc No Good No 6‐Sep

W‐3 S‐2 Wall Paper Second Floor: Room 215‐

Wall B Misc No Good No 6‐Sep

W‐3 S‐1 Wall Paper Second Floor:

C452Room 213‐Wall Misc No Good No 6‐Sep

Sample Sheet 10

E‐4 Window Putty Exterior: Wing 1 Misc Yes Good No 8‐Sep

E‐3 Window Putty Exterior: Wing 1 Misc Yes Good No 8‐Sep

E‐2 Composition Exterior: Roof Misc Yes Good No 8‐Sep

E‐1 Mastic Exterior: Roof Surfacing Yes Good Yes‐10% 8‐Sep

Sample Sheet 11

404‐11 Duct Wrap Building 404: C24Bay 1‐

Upper Platfrom TSI Yes Good No 7‐Sep

404‐10 Insulation Board Building 404: Bay 1‐ Upper Platfrom

TSI Yes Good No 7‐Sep

404‐9 Pink Insulation Building 404: Dispatch TSI Yes Good No 7‐Sep

404‐8 Floor Tile Building 404: Dispatch Misc No Good No 7‐Sep

404‐7 Ceiling Tile Building 404: Dispatch Misc Yes Good No 7‐Sep

404‐6 Cove Base Building 404: Dispatch Misc No Good No 7‐Sep

404‐5 GWB Building 404: Dispatch Surfacing Yes Good No 7‐Sep

404‐4 GWB Building 404: Dispatch Surfacing Yes Good No 7‐Sep

404‐3 GWB Building 404: Dispatch Surfacing Yes Good No 7‐Sep

404‐2 Mastic Dot Building 404: Dispatch Misc No Good No 7‐Sep

404‐1 Vent Paper Tape Building 404: Lube

Room TSI Yes Good No 7‐Sep

Sample Sheet 3

Sample # Materials & Description Location Type Friable Condition Qty Asbestos Date

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

8‐Sep

W‐1 S‐1

W‐1 S‐9 Sheet Rock‐Joint

Compound Hall B‐Wall‐B Yes Good

W‐1 S‐8 Sheet Rock‐Surfacing Hall B‐Wall‐B Surfacing Yes Good 8‐Sep

W‐1 S‐7 Plaster Yes Good 8‐Sep

8‐Sep

W‐1 S‐6 Sheet Rock‐Joint

Compound Room 53‐Wall B Yes Good

W‐1 S‐5 Sheet Rock‐Surfacing Room 53‐Wall B Surfacing Yes Good

8‐Sep

W‐1 S‐4 Formica Mail Room No Good 8‐Sep

W‐1 S‐3 Formica Latrine‐Wall B No Good 8‐Sep

8‐Sep

W‐1 S‐2 Sheet Rock‐Joint

Compound Shower‐Wall E Yes Good

W‐1 S‐1 Sheet Rock‐Surfacing Shower‐Wall E Surfacing Yes Good

8‐Sep

Sample # Materials & Description Location Type Friable Condition Qty Asbestos Date

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

W‐1 S‐1

8‐Sep

W‐1 S‐1

W‐1 S‐9 Sheet Rock‐Joint Compound Hall B‐Wall‐B Yes Good

W‐1 S‐8 Sheet Rock‐Surfacing Hall B‐Wall‐B Surfacing Yes Good 8‐Sep

W‐1 S‐7 Plaster Yes Good 8‐Sep

8‐Sep

W‐1 S‐6 Sheet Rock‐Joint Compound Room 53‐Wall B Yes Good

W‐1 S‐5 Sheet Rock‐Surfacing Room 53‐Wall B Surfacing Yes Good

8‐Sep

W‐1 S‐4 Formica Mail Room No Good 8‐Sep

W‐1 S‐3 Formica Latrine‐Wall B No Good 8‐Sep

8‐Sep

W‐1 S‐2 Sheet Rock‐Joint Compound Shower‐Wall E Yes Good

W‐1 S‐1 Sheet Rock‐Surfacing Shower‐Wall E Surfacing Yes Good

8‐Sep

Laboratory Samples

White Shield Environmental

TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.

13509 East Boundary Road, Suite B, Midlothian, VA 23112

804-739-1751 • fax: 804-739-1753

BULK ASBESTOS SAMPLE ANALYSIS SUMMARY

320 N 20th Ave Pasco, WA 99301

Fort Vancouver - Bldg 404 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916H

9/16/2011 9/16/2011 9/19/2011

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

CLIENT JOB/ #:

1 404-1 / White fibers NAD 2%98% Cellulose

2 404-2 / Brown adhesive NAD 100%

3 404-3 / White powder, brown fibers NAD 80%20% Cellulose

4A 404-4-GWB / White powder, brown fibers NAD 80%20% Cellulose

4B 404-4-Mastic / Brown adhesive NAD 100%

5 404-5 / White powder, brown fibers NAD 80%20% Cellulose

6A 404-6-Cove base / Red rubber NAD 100%

6B 404-6-Mastic / Brown adhesive NAD 100%

7 404-7 / Gray fibers NAD 10%70% Cellulose 20% Fiberglass

Tuesday, September 20, 2011 Page 1 of 2

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

Feng Jiang, MS Senior Geologist, Laboratory Director

Yuedong Fang, Senior Geologist

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 404 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916H

9/16/2011 9/16/2011 9/19/2011

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

8A 404-8-Tile / Beige vinyl NAD 100%

8B 404-8-Mastic / Yellow adhesive NAD 100%

9 404-9 / Pink fibers NAD 2%98% Fiberglass

10 404-10 / Yellow fibers NAD 2%98% Fiberglass

11 404-11 / White fibers NAD 2%98% Cellulose

Total Samples/Layers Analyzed: 14

Tuesday, September 20, 2011 Page 2 of 2

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916Q

9/16/2011 9/17/2011 9/19/2011

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

1 W-1 S-1 / Gray granular, white powder NAD 100%

2 W-1 S-2 / Gray granular, white powder NAD 100%

3A W-1 S-3-Cove base / Beige rubber NAD 100%

3B W-1 S-3-Mastic / Yellow adhesive NAD 100%

4 W-1 S-4 / White powder NAD 100%

5 W-1 S-5 / White powder NAD 100%

6 W-1 S-6 / White powder NAD 100%

7 W-1 S-7 / White powder, brown fibers NAD 75%25% Cellulose

8 W-1 S-8 / White powder & fibers NAD 90%10% Fiberglass

Monday, September 19, 2011 Page 1 of 2

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916Q

9/16/2011 9/17/2011 9/19/2011

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

9A W-1 S-9-Stair Tread / Blue rubber NAD 100%

9B W-1 S-9-Mastic / Yellow adhesive NAD 100%

Total Samples/Layers Analyzed: 11

Monday, September 19, 2011 Page 2 of 2

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916L

9/16/2011 9/16/2011 9/19/2011

Y. FangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

1 W-1 S-1 / White powder, brown fibers NAD 10%90% Cellulose

2 W-1 S-2 / White powder, brown fibers NAD 75%25% Cellulose

3 W-1 S-3 / Tan formica NAD 100%

4 W-1 S-4 / Brown fimica NAD 100%

5 W-1 S-5 / White powder, brown fibers NAD 5%95% Cellulose

6 W-1 S-6 / White powder, brown fibers NAD 70%30% Cellulose

7 W-1 S-7 / Gray granular NAD 100%

8 W-1 S-8 / Brown fibers, white paint NAD 100%

9 W-1 S-9 / White powder,brown fibers NAD 80%20% Cellulose

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916L

9/16/2011 9/16/2011 9/19/2011

Y. FangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

CLIENT JOB/ #:

Total Samples/Layers Analyzed: 9

Monday, September 19, 2011 Page 2 of 2

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Jo#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916I

9/16/2011 9/16/2011 9/19/2011

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

1 E-1 / Black adhesive 10% Chrysotile 90%

2 E-2 / Black tar-like NAD 75%25% Fiberglass

3 E-3 / White powder NAD 100%

4 E-4 / White powder NAD 100%

Total Samples/Layers Analyzed: 4

Monday, September 19, 2011 Page 1 of 1

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916M

9/16/2011 9/16/2011 9/19/2011

Y. FangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

1 W-1 S-1 / Gray granular, white powder NAD 100%

2A W-1 S-2-Tile / Off-white vinyl NAD 100%

2B W-1 S-2-Mastic / Black adhesive NAD 100%

3 W-1 S-3 / White fibers NAD 2%98% Cellulose

4 W-1 S-4 / White powder, brown fibers NAD 80%20% Cellulose

5 W-1 S-5 / White powder, brown fibers <1% Chrysotile (<1% Chrysotile in JC)

80%20% Cellulose

6 W-1 S-6 / White powder, brown fibers NAD 80%20% Cellulose

7 W-1 S-7 / Brown fibers, blue paint NAD 5%95% Cellulose

8 W-1 S-8 / White powder, brown fibers NAD 75%25% Cellulose

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916M

9/16/2011 9/16/2011 9/19/2011

Y. FangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

9 W-1 S-9 / White powder, brown fibers NAD 80%20% Cellulose

10 W-1 S-10 / White powder, brown fibers NAD 80%20% Cellulose

11 W-1 S-11 / Tan powder NAD 100%

12A W-1 S-12-Cove base / Black rubber NAD 100%

12B W-1 S-12-Mastic / Brown adhesive NAD 100%

13 W-1 S-13 / Gray granualr, white powder NAD 100%

Total Samples/Layers Analyzed: 15

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916R

9/16/2011 9/17/2011 9/19/2011

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

1 W-2 S-1 / Off-wwhite powder NAD 100%

2 W-2 S-2 / Gray granular NAD 100%

3 W-2 S-3 / White powder NAD 100%

4 W-2 S-4 / Gray granular, white powder NAD 100%

5 W-2 S-5 / White powder,brown fibers NAD 25%75% Cellulose

6 W-2 S-6 / White powder,brown fibers NAD 80%20% Cellulose

7 W-2 S-7 / Gray granular NAD 100%

Total Samples/Layers Analyzed: 7

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916K

9/16/2011 9/16/2011 9/19/2011

Y. FangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

1 W-2 S-1 / White powder, brown fibers NAD 75%25% Cellulose

2 W-2 S-2 / White powder, brown fibers NAD 75%25% Cellulose

3 W-2 S-3 / Tan formica NAD 90%10% Cellulose

4A W-2 S-4-Lino., like / Brown limoleum-like NAD 100%

4B W-2 S-4-Mastic / Yellow adhesive NAD 100%

5 W-2 S-5 / White powder NAD 100%

6 W-2 S-6 / White powder NAD 100%

Total Samples/Layers Analyzed: 7

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916N

9/16/2011 9/17/2011 9/19/2011

Y. FangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

1A W-2 S-1-Cove base / Brown rubber NAD 100%

1B W-2 S-1-Mastic / Yellow adhesive NAD 100%

2 W-2 S-2 / Gray fibers NAD 2%98% Cellulose

3 W-2 S-3 / Gray fibers NAD 10%85% Cellulose 5% Fiberglass

4 W-2 S-4 / Gray fibers NAD 10%85% Cellulose 5% Cellulose

5 W-2 S-5 / White powder NAD 100%

6 W-2 S-6 / Gray granular, white powder NAD 100%

7A W-2 S-7-Cove base / Tan rubber NAD 100%

7B W-2 S-7-Mastic / Yellow adhesive NAD 100%

Monday, September 19, 2011 Page 1 of 3

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916N

9/16/2011 9/17/2011 9/19/2011

Y. FangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

8A W-2 S-8-Lino. / Beige lino., gray fibers NAD 85%15% Cellulose

8B W-2 S-8-Mastic / Yellow adhesive NAD 100%

9 W-2 S-9 / Tan formica NAD 90%10% Cellulose

10 W-2 S-10 / Off-white formica NAD 90%10% Cellulose

11 W-2 S-11 / Gray fibers NAD 2%98% Cellulose

12 W-2 S-12 / Brown vinyl NAD 100%

13 W-2 S-13 / Gray granular, white powder NAD 100%

14 W-2 S-14 / Gray granular, white powder NAD 100%

15 W-2 S-15 / Gray granular, white powder 100%

Monday, September 19, 2011 Page 2 of 3

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916N

9/16/2011 9/17/2011 9/19/2011

Y. FangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

CLIENT JOB/ #:

Total Samples/Layers Analyzed: 18

Monday, September 19, 2011 Page 3 of 3

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916S

9/16/2011 9/17/2011 9/19/2011

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

1 W-3 S-1 / Gray granular, white powder NAD 100%

2 W-3 S-2 / Gray granular, white powder NAD 100%

3 W-3 S-3 / White powder NAD 100%

4 W-3 S-4 / White powder, brown fibers NAD 60%40% Cellulose

5 W-3 S-5 / White powder, brown fibers NAD 80%20% Cellulose

6 W-3 S-6 / White powder, brown fibers NAD 40%60% Cellulose

7 W-3 S-7 / White powder, brown fibers NAD 70%30% Cellulose

8 W-3 S-8 / White powder, brown fibers NAD 70%30% Cellulose

9 W-3 S-9 / Brown fibers NAD 2%98% Cellulose

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Job#: 111-026-1

612 E Reserve St. Vancouver, WA 98661

110916S

9/16/2011 9/17/2011 9/19/2011

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

10 W-3 S-10 / Yellow fibers NAD 2%98% Cellulose

11A W-3 S-11-Tile / Blue vinyl NAD 100%

11B W-3 S-11-Mastic / Brown adhesive NAD 100%

12 W-3 S-12 / Brown fibers NAD 2%98% Cellulose

13A W-3 S-13-Tile / Tan vinyl NAD 100%

13B W-3 S-13-Mastic / Black adhesive 5% Chrysotile 95%

Total Samples/Layers Analyzed: 15

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993 (EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

13509 East Boundary Road, Suite B, Midlothian, VA 23112

Fort Vancouver - Bldg 987 Jo#: 111-987-1

612 E Reserve St. Vancouver, WA 98661

110916J

9/16/2011 9/16/2011 9/19/2011

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

1 W-3 S-1 / Brown adhesive NAD 100%

2 W-3 S-2 / Brown fibers NAD 2%98% Cellulose

3 W-3 S-3 / Gray granular NAD 100%

4 W-3 S-4 / Brown vinyl NAD 100%

5 W-3 S-5 / Gray powder & fibers 10% Chrysotile 70%20% Cellulose

6 W-3 S-6 / /White fibers, foil NAD 10%90% Cellulose

7 W-3 S-7 / White, brown fibers 90% Chrysotile 2%8%…