Attachment IV Request for Information Form Q1A1.rtf

RTF text file 333 KB Posted

Attached to
USS DEWEY (DDG-105) FY26 6C1 CNO SRA(d) BUNDLE #2, Chief of Naval Operation Availability Yokosuka Japan
Solicitation number
N6264926RA004
Issued by

About this file

This document is a Request for Information (RFI) form related to the USS DEWEY (DDG-105) ship repair contract. The RFI, dated 25 October 2025, contains a specific contractor inquiry about tank cleaning requirements for tanks 5-78-2-F and 4-78-2-F, and questions regarding dewatering of Tank Group 1. The technical reviewer responded on 30 October 2025, confirming that tank 4-78-2-F should be cleaned and that dewatering of Tank Group-1 is not required due to the dry dock availability.

The associated federal contract opportunity is for a Chief of Naval Operation Availability (CNO) at the NAVSUP Fleet Logistics Center Yokosuka, Japan. The solicitation (N6264926RA004) covers fourteen Task Group Instructions for ship repair, overhaul, preservation, and replacement work on the USS DEWEY. The period of performance is from 30 March 2026 through 14 December 2026, with proposals due by 17 November 2025. The work will be conducted at Yokosuka Naval Base, and proposers must follow specific submission guidelines, including identifying hazardous materials and potential sea transportation requirements.

Text of this file

file_0.jpg file_1.wmf

ATTACHMENT IV: REQUEST FOR INFORMATION (RFI)

DATE OF REQUEST: 25 Oct 20025

CONTRACTOR: -

RFP Number: N6264926RA004

PAGE Number(s): 1 CONTRACTOR QUESTION(s):

38K4212344A01 For cleaning 5-78-2-F, we believe 4-78-2-F also required to be cleaned. Will it not be required in TGI?

Is it possible to inform us the reason of Dewatering of Tank Group 1 is not included in para 5.1?

DO NOT WRITE BELOW THIS LINE (FOR GOVERNMENT USE ONLY)

TECHNICAL REVIEWER:

DATE: 30 Oct 2025

TGI NO: 38K4212344A01

DATE: 30 Oct 2025

SPEC CHG: Y/N

DWG/REF CHG: Y/N

RQMTS CHG: Y/N

MAT'L CHG: Y/N

RESPONSE TO CODE 200:

The tank 4-78-2-F should be cleaned so the TGI needs to correct.

Dewatering of Tank Group-1 is not required because 6C1 avail is dry dock so we don't need to care ship's stability.

Other files

File Type Posted
Attachment II Proposal Breakdown Form (Contractor Response Required).xlsx XLSX spreadsheet
Attachment IV Request for Information Form Q2A2.rtf RTF text file
Solicitation Amendment N6264926RA0040002 SF 30.pdf PDF
Solicitation Amendment N6264926RA0040001 SF 30.pdf PDF
TGI_38K4265405A01_c0v0.pdf PDF
38K4212387A01_c0v0.pdf PDF
Attachment VII QASP 26RA004 Bun2.pdf PDF
Solicitation - N6264926RA004.pdf PDF
TGI_38K4286504A01_c1v1.pdf PDF
Attachment VI Warranty Tracking Information.pdf PDF
TGI_38K4212359A02_c1v1.pdf PDF
TGI_38K4212357A01_c1v1.pdf PDF
38K4212301A01_c0v0.pdf PDF
TGI_38K4262204A01_c0v0.pdf PDF
TGI_38K4212354A01_c0v0.pdf PDF
Attachment IV Request for Information Form.rtf RTF text file
Attachment V Source of Repair Instruction.pdf PDF
Attachment III N6264926RA004 Government Furnished Property (GFP-GFM listings).xlsx XLSX spreadsheet
TGI_38K4212301T01_c0v0.pdf PDF
38K4212361A01_c0v0.pdf PDF
Attachment IX POP List.xlsx XLSX spreadsheet
TGI_38K4212359A01_c0v0.pdf PDF
TGI_38K4286503A01_c0v0.pdf PDF
TGI_38K4212344A01_c1v1.pdf PDF
Attachment II Proposal Breakdown Form (Contractor Response Required).xlsx XLSX spreadsheet
Attachment VIII Contract Data Sheet 26RA004.pdf PDF
38K42123ACA01.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .