Attachment T - Revised Drawing CU101B.pdf
PDF 1020 KB Posted
- Solicitation number
- N6247022R3000
About this file
This document is a utility plan drawing for a federal construction project to build Rapid Airfield Damage Recovery storage facilities at Aviano Air Base in Italy. The drawing depicts the site layout and existing utilities, and identifies proposed utility tie-ins and new utility lines to support the project. Utilities shown include sanitary sewer lines, storm drains, water lines, gas lines, and communications and electrical infrastructure. Key aspects called out on the drawing include a retention pond, lift station, fuel/water separator, underground monitoring wells, fire hydrants, manholes, cleanouts, and notes regarding field verification of existing utilities. The related federal contract opportunity provides additional context, with the solicitation number and name identifying the project as P-002 EDI: Rapid Airfield Damage Recovery Storage Facilities at Aviano Air Base, to be completed for the Department of the Navy Naval Facilities Engineering Command.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
R1
R2
S
S
S
S
S
S
S
S
SAN
SAN
SAN
SAN
FW
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
SAN
SAN
SAN
S
S
SAN
SAN
SAN
SA
N
F
F
F
F
F
F
F
F
F
F
F
F
F
F
W
W
W
W
W
W
W
W
W
W
W
PG
AS
PG
AS
PG
AS
PG
AS
PGAS
RETENTION POND (590 sqm)
B.O.P. ELEV.=138.00
BACINO DI RITENZIONE (590 mq)
QUOTA BASE TUB.=138.00
PG
AS
PG
AS
PG
AS
PG
AS
PG
AS
PG
AS
PG
AS
PG
AS
PG
AS
PG
AS
PG
AS
PGAS
PGAS
PGAS
PGAS
PGAS
G
AS
G
AS
GAS
EW
EW
EW
EW
EW
EW
EW
EW
EW
EW
EW
EW
EW
EW
EW
EW
EW
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
EXIST STORM M.H
TOP ±137.77
BOTTOM ±134.80
(NO INCOMING PIPE)
EXIST SAN M.H
TOP ±138.70
BOTTOM ±135.85
N.E. FL.=±135.68
S.W. FL.=±135.64
EXIST SAN C.O.
TOP ±138.86
BOTTOM ±138.56
EXIST SAN M.H
TOP ±138.48
BOTTOM ±135.67
N.W. FL.=±135.43
N.E. FL.=±135.45
S.E. FL.=±135.45
PERIM
ETER RO
AD
STR
AD
A PER
IM
ETR
ALE
50FT (15M
) AT/FP STANDO
FF
15M
AT/FP STALLO
INSTALLATIO
N BO
UNDARY
C O
N
FIN
E D
ELL'IN
STALLAZIO
N
E
SI
TE
U
TI
LI
TY
P
LA
N
(1 O
F 2)
CU101B
EXISTING CONDITIONS, TOPOGRAPHY, AND UTILITY
SURVEY PROVIDED BY:
CSG PALLADIO
STRADIA SAVIAONA
278/1-36100 VICENZA
TEL ++39/0444 304091
FAX ++39/0444 313136
DATE OF SURVEY : JULY 2021
CONTROL POINT SUMMARY TABLE
( BENCHMARK: UTM 33N BASE UNITS METERS)
Meters 1:400
20100 5
NO. COORDINATES ELEVATION
5099052,740 312849,878 139,006
N E
SITE 2 (R1)
5098999,548 312897,342 138,835SITE 2 (R2)
COORDINATE QUOTE ALT.NR.
RILIEVO DELLE CONDIZIONI
ESISTENTI, TOPOGRAFICO E
DEI SOTTOSERVIZI
FORNITO DA CSG PALLADIO
DATA RILIEVI: LUGLIO 2021
SITE 2 RADR
STORAGE FACILITY
2 CRATER REPAIR KIT
FFE=139.01
34 ISO
C
O N
TAIN
ER
S / 34 C O
N
TAIN
ER
S ISO
MATCH LINE (SHEET 1 OF 2)
LINEA DI CORRISPONDENZA (SCHEDA 1 DI 2)
TABELLA DI RIEPILOGO DEI PUNTI DI RIFERIMENTO
CAPISALDI: UTM 33N BASE UNITA' IN METRI
SITO 2 RADR
MAGAZZINO
2 KIT RIPARAZIONE
CRATERI
FFE=139.01
SI
TO
P
IA
NT
A
DE
I S
OT
TO
SE
RV
IZ
I ( 1 D
I 2
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
1 2 3 4 5
1 2 3 4 5
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D
EP
AR
TM
EN
T
O F
T H
E N
AV
Y
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
AT
LA
NT
IC
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
N O
R
FO
LK
, V
A
AV
IA
NO
A
IR
B
AS
E
AV
IA
NO
, I
TA
LY
P-
ED
I-R
AD
R
ST
O
RA
G E
FA
CI
LI
TY
DES DRW CHK
SATISFACTORY TO DATE : 04 AUGUST 2022
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
A
B
C
D
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
A
B
C
D
JMW
DESIGN MANAGER:
BRANCH MANAGER:
PM/DM:
FIRE PROTECTION:
RICHARD STEPHENS, PE
LET/LRP
DPS
FI
LE
N
AM
E:
T
:\A ct iv e
Pr oj ec ts
\2
1\ (1
) A vi an o
Ai r F or ce
B as e\ D ra w in gs
\W or ki ng
C
AD
D ra w in gs \A
VI
AN
O P
LA
N
S
ET
.d w g L
AY
O
U T
N
AM
E:
C
U
1B P
LO
TT
ED
: T ue sd ay , M ar ch
7,
- 5
:0 0p m U
SE
R
: T ra na
NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018
1659896
AT
LA
N
TI
C D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
Approved by Allan Lucht, via Email.
N6247022R3000
DES: MD DRW: CHK: JM
99026
MARGARET L. DUBBIN
DISCLAIMER
UPON ACCEPTANCE OF THESE PLANS FOR CONSTRUCTION, THE CONTRACTOR AGREES TO FAMILIARIZE HIMSELF WITH THE PROJECT AND VERIFY THE LOCATION AND CORRECTNESS OF ANY AND ALL APPURTENANCES, RIGHT-OF-WAY, PROPERTY LINES, ELEVATIONS, OBSTRUCTIONS, HAZARDS, OR CONFLICTS THAT MAY EXIST UPON EXAMINATION OF CURRENT FIELD CONDITIONS. DESIGN OF THESE PLANS WAS BASED UPON AVAILABLE INFORMATION AND INTERPRETATION OF AVAILABLE DATA, ANY DISCREPANCIES DISCOVERED, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD FOR EVALUATION, THE CONTRACTOR SHALL ACCEPT ALL LIABILITY AND RISKS FOR CONSTRUCTION PROCEEDING PRIOR TO ENGINEERS EVALUATION.
ESCLUSIONE DI RESPONSABILITÀ
DOPO L'ACCETTAZIONE DI QUESTI PIANI DI COSTRUZIONE, L'APPALTATORE ACCETTA DI FAMILIARIZZARE SE STESSO CON IL PROGETTO E DI VERIFICARE LA POSIZIONE E LA CORRETTEZZA DI QUALSIASI ATTREZZATURA, DIRITTO DI PASSAGGIO, LINEE DI PROPRIETÀ, ALTEVAZIONI, OSTACOLI, PERICOLI O CONFLITTI ESAME DELLE CONDIZIONI DI CAMPO ATTUALI. LA PROGETTAZIONE DI QUESTI PIANI È STATA BASATA SULLE INFORMAZIONI DISPONIBILI E SULL'INTERPRETAZIONE DEI DATI DISPONIBILI, QUALSIASI DISCREPANZA RILEVATA, DEVE ESSERE PORTATA IMMEDIATAMENTE ALL'ATTENZIONE DELL'INGEGNERE DEL RECORD PER LA VALUTAZIONE, IL FORNITORE ACCETTA TUTTE LE RESPONSABILITÀ EI RISCHI PER IL PROCEDIMENTO DI PRECISIONE DELLA COSTRUZIONE.
N
EXISTING FRENCH DRAIN
RETENTION POND (590 sqm) SEE
GRADING AND DRAINAGE PLAN
FIRE HYDRANT WITH APPURTENANCES
Ø200 SANITARY SEWER LINE
DOUBLE CLEAN OUT (SEE CK551)
EXISTING GROUNDWATER MONITORING
WELL MONITOR
TRENCH DRAIN
Ø300 STORM DRAIN (SEE DETAILS)
GAS LINE
TIE Ø100 SANITARY SEWER FORCEMAIN TO
EXISTING SEWER MAIN, ASSUMED 216
METERS. FIELD VERIFY LOCATION AND
INVERT OF EXISTING MANHOLE ADJUST
TIE WATER LINE TO EXISTING WATER MAIN,
FIELD VERIFY TIE WATER LINE TO EXISTING
LINE
Ø200MM WATER LINE WITH M.J
SANITARY SEWER LIFT STATION WITH
WETWELL
Ø50 DOMESTIC WATER LINE SERVICE
EXISTING Ø200 GRAVITY SANITARY SEWER
LINE (ASSUMED LOCATION)
POZZO DI ESTRAZIONE ESISTENTE
BACINO DI RITENZIONE (590MQ) VEDERE
PLANIMETRIE DEI LIVELLAMENTI E DRENAGGIO
DRANTE ANTINCENDIO E RELATIVI ACCESSORI
SEPARATORE DI OLII / ACQUA
POZZO DI MONITORAGGIO DELLE
ACQUE SOTTERRANEE
CANALE DI DRENAGGIO (VEDERE I DETTAGLI)
LINEA DEL GAS
STAZIONE DI SOLLEVAMENTO
ALLACCIARE LA NUOVA LINEA DELL' ACQUA
ALLA LINEA ESISTENTE PRINCIPALE,
L'APPALTATORE DEVE VERIFICARE LA
POSIZIONE DELLA LINEA ESISTENTE
LINEA DI ACQUA SANITARIA
OIL WATER SEPARATOR
LINEA FOGNARIA Ø200
DOPPIO POZZETTO DI ISPEZIONE (VEDERE I
DETTAGLI
Ø300 STORM DRAIN (VEDI DETTAGLI)
ALLACCIARE LA NUOVA LINEA FOGNARIA Ø100 ALLA
LINEA ESISTENTE PRINCIPALE, A CIRCA 216M.
L'APPALTATORE DEVE VERIFICARE SUL POSTO IL
PUNTO DI ALLACCIO E LA QUOTA DI SCORRIMENTO
DEL POZZETTO ESISTENTE E ADEGUARE
LINEA DELL'ACQUA Ø200 W/M.J.
LINEA FOGNARIA ESISTENTE A GRAVITA' Ø200
SITE 2 UTILITY PLAN (1 OF 2)
SITO 2 PIANTA DEI SOTTOSERVIZI (1 DI 2)
Ø100 SANITARY SEWER SERVICE LINE
MIN. INV. 137.00 AT BLDG. PER MECHANICAL
SANITARY SEWER MANHOLE19
EXISTING WATER LINE (ASSUMED
LOCATION)
LINEA DI SERVIZIO FOGNARIO SANITARIO
MINIMO 137,00 A BLDG. PER MECCANICO
POZZETTO FOGNARIO
LINEA DELL'ACQUA ESISTENTE (POSIZIONE
APPROSSIMATIVA)
Ø200 TIE FIRE PROTECTION LEAD-IN TO
POTABLE WATER LINE
Ø200 TIE PROTEZIONE ANTINCENDIO
LEAD-IN ALLA LINEA DI ACQUA POTABILE
COMMUNICATIONS SEE
TELECOMMUNICATION PLANS
21 COM MH
ELECTRICAL HIGH VOLTAGE SEE
ELECTRICAL PLANS
EHV MH
14121650
HVAC UNITS, SEE ELECTRICAL AND
MECHANICAL PLANS
23 EHV MH
IMPORTANT NOTE:
EXISTING CONDITIONS & UTILITY SURVEY DATA
PROVIDED BY SURVEYOR CONTAINS SIGNIFICANT
DISCREPANCIES FROM SITE INSPECTION &
GOVERNMENT FURNISHED DATA. DEMOLITION
PLAN & DESIGN DRAWINGS HAVE BEEN
DEVELOPED BASED UPON BEST AVAILABLE
INFORMATION. CONTRACTOR TO FIELD VERIFY ALL
UTILITIES PRIOR TO CONSTRUCTION
NOTA IMPORTANTE:
I DATI DELLA CONDIZIONE ESISTENTE ED IL RILIEVO DEI
SOTTOSERVIZI FORNITI DAL TECNICO CHE HA ESEGUITO IL
SOPRALLUOGO CONTENGONO SIGNIFICATIVE DISCREPANZE
RISPETTO AL SOPRALLUOGO E AI DATI FORNITI DAL GOVERNO.
LA PIANTA DEMOLIZIONI E I DISEGNI DI PROGETTAZIONE
SONO STATI SVILUPPATI IN BASE ALLE MIGLIORI
INFORMAZIONI DISPONIBILI. L'APPALTATORE DEVE
VERIFICARE SUL LUOGO TUTTI I SOTTOSERVIZI PRIMA DELLA
FASE DI COSTRUZIONE
AutoCAD SHX Text O/W
AutoCAD SHX Text 1 : 400
AutoCAD SHX Text ATRan
AutoCAD SHX Text
KEY #
AutoCAD SHX Text
ENGLISH NOTE
AutoCAD SHX Text
NOTA/ITALIANA
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text A4
AutoCAD SHX Text
AutoCAD SHX Text
REVISED PIPE DIAMETER IN ITALIAN TRANSLATION OF KEYNOTES 9
AutoCAD SHX Text
08 MARCH 2023
AutoCAD SHX Text
| Sheets and Views |
| CU101B |
File details come from the government source that posted it. Updated .